HomeMy WebLinkAboutP_1601_CUP_Drawings_230316_v1.pdf223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com 3/15/2023 4:56:11 PM 102987.00 1601 LIND AVE SW RENTON WA 98057 CONDITIONAL USE PERMIT UW DLMP CENTRAL LABS TI UW DLMP GENERAL NOTES 1. DRAWINGS HAVE BEEN PREPARED ON AN ORIGINAL SHEET SIZE OF 36" x 48". 2. HORIZONTAL DIMENSIONS SHOWN INDICATE FACE OF CONCRETE, FACE OF SHEATHING, CENTERLINE OF COLUMN GRIDLINE, OR FACE OF FINISH (INTERIOR), UNLESS OTHERWISE NOTED. VERTICAL DIMENSIONS INDICATE TOP OF SLAB, TOP OF SUBFLOOR, UNLESS OTHERWISE NOTED. 3. THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF NBBJ AND HAVE BEEN PREPARED FOR USE IN THE EXECUTION OF THE ENCLOSED PROJECT. USE OR REPRODUCTION FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN PERMISSION OF NBBJ IS PROHIBITED. PROJECT NARRATIVE THE UNIVERSITY OF WASHINGTON DEPARTMENT OF LABORATORY MEDICINE AND PATHOLOGY IS PROPOSING TO CONSOLIDATE THE MAJORITY OF THEIR NON-EMERGENCY TESTING FACILITIES INTO AN OFF-SITE LOCATION AT AN EXISTING OFFICE BUILDING LOCATED AT 1601 LIND AVE SW, RENTON, WA 98057 (APN 3340404006). ADDITIONAL MEDICINE TESTING LAB FACILITIES, SUPPORT OFFICES AND AMENITIES WOULD OCCUPY THE REMAINING FLOORS (2-5). LEVEL 1 IS CURRENTLY OCCUPIED BY UW DLMP BUT WILL BE REVISED TO MEET THE NEW PROGRAM. THE CURRENT SIZE OF THE TESTING LAB IS APPROXIMATELY 15,240 SF OF LEVEL 1. THE ENTIRE BUILDING IS LEASED BY THE UNIVERSITY OF WASHINGTON. NOTE THE UPPER FLOORS OF THE BUILDING ARE PREDOMINANTLY VACANT OFFICE SPACE. RENOVATIONS TO THE INTERIOR OF BUILDING WILL BE REQUIRED TO SUPPORT THE TECHNICAL EQUIPMENT AND LAYOUT TO SUPPORT THE WORKFLOW. NEW FINISHES, CEILINGS, INTERIOR PARTITIONS, AND DOORS (INCLUDING CARD ACCESS SECURITY) WILL BE REQUIRED, IN ADDITION TO NEW ELECTRICAL, DATA, MECHANICAL EQUIPMENT, AND NEW SINKS (HAND-WASH AND LAB USE). NEW AIR HANDLING UNITS TO PROVIDE 100% OUTSIDE AIR FOR LAB SAFETY IS REQUIRED AND WILL BE LOCATED ON THE UPPER ROOF. ADDITIONAL MECHANICAL SCREENING WILL BE REQUIRED. RESTROOMS TO BE ADDED OR MODIFIED TO SUPPORT CURRENT STANDARDS. NEW SCREENING MAY BE REQUIRED FOR EXPANDED GENERATOR YARD LOCATED AT GRADE. NO TREES OR LANDSCAPE PLANNED TO BE REMOVED AS PART OF THIS PROJECT. THIS TESTING LAB WILL CONTAIN EQUIPMENT TO PERFORM SEVERAL TESTS ON SAMPLES THAT ARE COLLECTED IN OTHER LOCATIONS AND COURIERED TO THE FACILITY USING SMALL COURIER VEHICLES INCLUDING CARS AND SMALL PANEL TRUCKS (I.E., FEDEX). PATIENTS REQUIRING TESTING ARE NOT EXPECTED TO VISIT THE SITE. THE EXPECTED HOURS OF OPERATION WILL BE 24/7. APPROXIMATELY A TOTAL OF 600 - 750 FULL TIME STAFF WILL BE EMPLOYED (300-375 DAY, 180-225 EVENING & 120-150 NIGHT SHIFTS). THE 5.29-ACRE SITE IS LOCATED IN THE COMMERCIAL OFFICE (CO) ZONE, URBAN DESIGN DISTRICT ‘D’, AND THE EMPLOYMENT AREA COMPREHENSIVE PLAN LAND USE DESIGNATION. THE ADJACENT PROPERTIES ARE CO AND IM (MEDIUM INDUSTRIAL). THE CURRENT USE OF LEVEL 1 IS A MEDICAL TESTING LAB, AND THE REMAINDER OF THE BUILDING IS OFFICE USE. THE PROPOSED USE FOR THE ENTIRE BUILDING IS A MEDICAL TESTING LAB. “LABORATORIES: RESEARCH, DEVELOPMENT, AND TESTING” ARE SPECIFIED AS AD (ADMINISTRATIVE CONDITIONAL USE) UNDER THE CO ZONING DESIGNATION. LEGAL DESCRIPTION LEGAL DESCRIPTION: PARCEL A: LOT 2, CITY OF RENTON SHORT PLAT NUMBER 431-79, ALSO KNOWN AS VALLEY OFFICE & INDUSTRIAL PARK – SUBDIVISION NO. 1, RECORDED UNDER RECORDING NUMBER 8002269013, IN KING COUNTY, WASHINGTON; EXCEPT THOSE PORTIONS THEREOF CONVEYED TO THE CITY OF RENTON FOR STREET PURPOSED BY DEEDS RECORDED UNDER RECORDING NUMBERS 8007070464, 8008200077 AND 8202160354. KING COUNTY DEPARTMENT OF ASSESSMENTS LEGAL: HILLMANS EARLINGTON GARDENS #1 LOT 2 LESS ST - CITY OF RENTON SP #431-79 REC #8002269013 SD SP DAF - ALL OF VAC BLKS 24 & 31 & VAC VALENTINE AVE BET SD BLKS OF SD SUBD LY S OF S MGN OF SW 16TH ST LESS STS PARCEL NUMBER: 334040-4006 GENERAL PROJECT INFORMATION THE PROPOSED PROJECT IS FOR TENANT IMPROVEMENTS OF AN EXISTING OFFICE BUILDING TO SUPPORT TECHNICAL EQUIPMENT AND LABORATORY WORKFLOW. THE PROPOSAL INCLUDES A CHANGE OF USE TO LABORATORIES: TESTING AND RESEARCH FOR FLOORS 2 THROUGH 5. CURRENTLY FLOOR 1 IS A LABORATORY USE. TENANT IMPROVEMENT SCOPE INCLUDES THE ENTIRE 2ND, 3RD, 4TH AND 5TH FLOORS AS WELL AS ROOFTOP ALTERATIONS INCLUDING STRUCTURAL AND MECHANICAL ENHANCEMENTS. THE ENTIRE 1ST FLOOR WILL BE A TENANT IMPROVEMENT COMPLETED IN PHASES PER THE CLIENT. NEW FINISHES, CEILINGS, INTERIOR PARTITIONS, AND DOORS (INCLUDING ACCESS SECURITY) WILL BE REQUIRED, IN ADDITION TO NEW ELECTRICAL, DATA, MECHANICAL EQUIPMENT, AND NEW SINKS (HAND-WASH AND LAB USE). NEW AIR HANDLING UNITS TO PROVIDE 100% OUTSIDE AIR FOR LAB SAFETY IS REQUIRED AND WILL BE LOCATED ON THE UPPER ROOF. NEW TRANSFORMERS AND GENERATORS WILL ALSO BE PROVIDED. THE BUILDING IS NOT CLASSIFIED AS A HIGH-RISE AND THE HIGHEST OCCUPIED LEVEL IS LESS THAN 75’ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT ACCESS. A NEW MECHANICAL/ PLUMBING PENTHOUSE IS PROPOSED TO SUPPORT NEW MECHANICAL AND PLUMBING NEEDS. WORK INCLUDES: • STRUCTURAL MODIFICATIONS FOR STRENGTHENING FLOOR AREAS TO MEET VIBRATION REQUIREMENTS, SUPPORT NEW EQUIPMENT AND SHAFT PENETRATIONS. • DEMOLITION OF NON-STRUCTURAL PARTITIONS AND FINISHES. • MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SAFETY SYSTEMS TO SUPPORT PROPOSED USE • NEW SERVICE ELEVATOR TO SUPPORT THE LAB FUNCTIONS. PROJECT NAME: UW DLMP CENTRAL LABS PROJECT SITE ADDRESS: 1601 LIND AVE SW, RENTON WA 98057 ZONING: COMMERCIAL OFFICE (CO) SITE FEATURES: FLOOD HAZARD AREA (100 YEAR) CURRENT USES (EXISTING BUILDING): LABORATORIES: RESEARCH, DEVELOPMENT AND TESTING - LEVEL 1 OFFICE - LEVELS 2-5 PROPOSED USES: PRINCIPLE USE: LABORATORIES: RESEARCH, DEVELOPMENT AND TESTING - LEVELS 1-5 ACCESSORY USE: OFFICE, GENERAL PARCEL NO: 3340404006 FLOOR AREA (EXISTING) 197,446 SF APPROX LOT AREA: 230,430 SF (5.29 AC) PROJECT AREA OF WORK: GROUND FLOOR: 39,888 SF SECOND FLOOR: 38,332 SF THIRD FLOOR: 38,332 SF FOURTH FLOOR: 38,332 SF FIFTH FLOOR: 38,332 SF ROOF: 2,460 SF MECHANICAL PENTHOUSE & STRUCTURAL / MECHANICAL UPGRADES TOTAL AREA OF WORK: 195,676 SF GENERAL PROJECT DESCRIPTION 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:56:11 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN SHEET INDEX, GENERAL INFORMATION & CODE SUMMARY GI002-A2 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 DRAWING INDEX SHEET # SHEET NAME 00-GENERAL GI001 COVER SHEET GI002-A2 SHEET INDEX, GENERAL INFORMATION & CODE SUMMARY GI004 LAND USE SUMMARY & NEIGHBORHOOD DETAIL MAP GI005 LANDSCAPE DIAGRAM 00-GENERAL: 4 06-STRUCTURAL S107 GENERATOR YARD PLAN AND DETAILS 06-STRUCTURAL: 1 07-ARCHITECTURAL AS101-A2 ARCHITECTURAL SITE PLAN AS102 ARCHITECTURAL SITE PLANS - ENLARGED AE001 ARCHITECTURAL NOTES AND SYMBOLS AD102-A1 F2 ARCHITECTURAL DEMOLITION PLAN AD103-A1 F3 ARCHITECTURAL DEMOLITION PLAN AD104-A1 F4 ARCHITECTURAL DEMOLITION PLAN AD105-A1 F5 ARCHITECTURAL DEMOLITION PLAN AD106 ROOF ARCHITECTURAL DEMOLITION PLAN AE101-A1 F1 FLOOR PLAN AE102 F2 FLOOR PLAN AE103 F3 FLOOR PLAN AE104 F4 FLOOR PLAN AE105 F5 FLOOR PLAN AE106 R1 ROOF PLAN AE201 EXTERIOR ELEVATIONS AE202 EXTERIOR ELEVATIONS 07-ARCHITECTURAL: 16 TOTAL SHEETS: 21 INCLUDES WRITE-UP AND OTHER SUPPORT FUNCTIONS WITHIN LAB CONTROL AREA APPROXIMATE LABORATORY GROSS FLOOR AREA F1 19,631 SF F2 27,283 SF F3 27,283 SF F4 27,283 SF F5 12,515 SF 113,997 SF COMPLIANCE PATH: ENERGY MODELING OR PRESCRIPTIVE - TBD ENERGY CODE SEISMIC DESIGN CATEGORY:D IBC 1613.3.5 RISK CATEGORY:II IBC T1604.5 STRUCTURAL A, H-3 20' GROUP B, S, SPRINKLERED:50' IBC 1020.4 • WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED CORRIDOR MAXIMUM DEAD END (IBC) H-3 150' (SPRINKLERED) B 300' (SPRINKLERED) A, S-1 250' (SPRINKLERED) OCCUPANCY MAXIMUM TRAVEL DISTANCE (SPRINKLERED) IBC T1017.2 EXIT ACCESS TRAVEL DISTANCE (IBC) GROUP S 29 100' (SPRINKLERED) H-3 3 25' (SPRINKLERED) GROUP B 49 100' (SPRINKLERED) GROUP A, M 49 75' (SPRINKLERED) OCCUPANCY GROUP MAXIMUM OCCUPANT LOAD MAXIMUM COMMON PATH OF TRAVEL (SPRINKLERED) IBC T1006.2.1 SPACES WITH SINGLE EXIT (IBC) OTHER EGRESS COMPONENTS: 0.2" / OCCUPANT IBC 1005.3.2 STAIRWAYS: 0.3" / OCCUPANT IBC 1005.3.1 EGRESS WIDTH FACTORS (IBC) OUTDOOR AREAS 15 NET IBC 1004.7 LOCKER ROOMS 50 GROSS EXERCISE ROOMS 50 GROSS BUSINESS AREAS 150 GROSS ASSEMBLY - UNCONCENTRATED 15 NET STORAGE / MECHANICAL 300 GROSS FUNCTION OF SPACE:OCCUPANT LOAD FACTOR: IBC T1004.5 OCCUPANT LOAD FACTORS (IBC) MEANS OF EGRESS MAXIMUM FLOOR AREA PER EXTINGUISHER: 11,250 SF IBC T906.3(1) FIRE EXTINGUISHER TYPE / SIZE: 4A-80B:C HAZARD CLASS: ORDINARY HAZARD - TBD NFPA 10 PORTABLE FIRE EXTINGUISHERS (IBC) YES: NFPA 13 IBC 903 AUTOMATIC SPRINKLER SYSTEM (IBC) FIRE PROTECTION GROUPS A, B, H, S DOC FF-1 OR CLASS II (SPRINKLERED) EXCEPTIONS: WOOD, VINYL, LINOLEUM, TERRAZZO, RESILIENT FLOORING THAT ARE NOT COMPRISED OF FIBERS IBC 804.1 INTERIOR FLOOR FINISH REQUIREMENTS (IBC) SET-OUT CONSTRUCTION CLASS A MATERIALS IBC 803.15.2 • NOT REQUIRED IF CONCEALED SPACE IS CUSTRUCTED OF NONCOMBUSTIBLE MATERIALS FURRED CONSTRUCTION FIREBLOCKED AT 8' O.C. BOTH DIRECTIONS IBC 803.15.1.1 S CLASS C CLASS C CLASS C H CLASS B CLASS B CLASS C B CLASS B CLASS C CLASS C A CLASS B CLASS B CLASS C OCCUPANCY (SPRINKLERED) EXIT ENCLOSURES CORRIDORS ROOMS AND SPACES IBC T803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS (IBC) SMOKE PARTITION ELEVATOR LOBBY NONRATED 710 / 3006.1 H-3 | A OCCUPANCY SEPARATION 2 HOUR 707 / 508.4 H-3 | B OCCUPANCY SEPARATION 1 HOUR 707 / 508.4 HORIZONTAL EXIT 2 HOUR 707 / 1026.1 EXIT PASSAGEWAYS 2 HOUR 707 / 1024.3 FIRE BARRIER SHAFTS / STAIR ENCLOSURE 2 HOUR 707 / 713 / 1023.1 TYPE: LOCATION: FIRE RATING: IBC INTERIOR PARTITIONS (IBC) PENTHOUSE 20' OR MORE NONRATED IBC 1510.2.4 30' OR MORE NONRATED FIRE SEPARATION DISTANCE: FIRE RATING: EXTERIOR WALL FIRE RESISTANCE RATINGS (IBC)IBC T602 ROOFS 1 HOURS FLOORS 2 HOURS • NOT LESS THAN RATING REQUIRED BY OTHER SECTIONS OF THE CODE INTERIOR NONBEARING WALLS 0 HOURS • WHERE SUPPORTING ROOF ONLY 1 HOURS INTERIOR BEARING WALLS 2 HOURS EXTERIOR BEARING WALLS 2 HOURS • WHERE SUPPORTING ROOF ONLY 1 HOURS PRIMARY STRUCTURAL FRAME 2 HOURS FIRE RESISTANCE RATINGS FOR BUILDING ELEMENTS (IBC) TYPE I-B (TYPE II-FR) IBC T601 FIRE RESISTIVE CONSTRUCTION BUILDING AREA 199,500.00 UNLIMITED 201,487 IBC 506 ROOF PENTHOUSE UNLIMITED 1,987 LEVEL 5 39,903.00 UNLIMITED NO CHANGE LEVEL 4 39,903.00 UNLIMITED NO CHANGE LEVEL 3 39,903.00 UNLIMITED NO CHANGE LEVEL 2 39,903.00 UNLIMITED NO CHANGE LEVEL 1 39,888 UNLIMITED NO CHANGE IBC T506.2 FLOOR AREAS (SQUARE FEET) STORIES 5 STORIES 12 STORIES IBC T504.4 HEIGHT ±77'-8" EXISTING 180'-0"IBC T504.3 EXISTING ALLOWABLE PROPOSED ALLOWABLE HEIGHT AND AREA (IBC) YES: NFPA 13 - SEE FIRE PROTECTION SECTION SPRINKLERED BUILDING TYPE I-B (TYPE II-FR)IBC 602, T601 CONSTRUCTION TYPE (IBC) ALTERATIONS COMPLY WITH IBC FOR NEW CONSTRUCTION 503.1 PRESCRIPTIVE COMPLIANCE TOILET ROOMS - FULLY ACCESSIBLE (EXCEPT F4) ALL RESTROOM FINISHES TO BE REPLACED AND MADE ACCESSIBLE. NEW SINGLE-USER RESTROOMS TO BE... 305.8.10-11 PROPOSED IMPROVEMENTS TO MEET 20% RULE 305.7 ALTERATIONS AFFECTING PRIMARY FUNCTION - YES 305.7 COMPLETE CHANGE OF OCCUPANCY - YES 305.4.2 ACCESSIBILITY NO INCREASE IN DESIGN LIVE LOAD ON EXISTING BUILDING 303 STRUCTURAL DESIGN H-3 ACCESSORY HIGH-HAZARD IBC 307.1 S-1 STORAGE, MODERATE HAZARD IBC 311.2 B BUSINESS IBC 304.1 A-3 ASSEMBLY - GENERAL IBC 303.4 OCCUPANCY GROUPS (PER IBC) PRESCRIPTIVE 301.3 COMPLIANCE METHOD PROJECT SCOPE ALTERATIONS 301.2, 301.3 • REFERENCES ARE IEBC UNO SUBJECT:PROJECT SPECIFIC:REFERENCE: 2016 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2016 NFPA 13 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2014 NFPA 70 NATIONAL ELECTRICAL CODE 2018 UNIFORM PLUMBING CODE - WA STATE AMENDMENTS, WAC 51-56 & 51-57 2018 INTERNATIONAL MECHANICAL CODE - WA STATE AMENDMENTS, WAC 51-52 2018 WASHINGTON STATE ENERGY CODE (WSEC) 2018 INTERNATIONAL FIRE CODE - WA STATE AMENDMENTS, WAC 51-54A 2018 INTERNATIONAL BUILDING CODE - WA STATE AMENDMENTS, WAC 51-50 2018 INTERNATIONAL EXISTING BUILDING CODE - WA STATE AMENDMENTS, WAC 51-50-480000 APPLICABLE CODES AND STANDARDS JURISDICTION: CITY OF RENTON WA BUILDING CODE SUMMARY PROJECT SITE CURRENT USES: LABORATORIES:RESEARCH, DEVELOPMENT AND TESTING OFFICES, GENERAL PROPERTY LINE PROPERTY LINEPROPERTY LINEPROPERTY LINELIND AVE SWVACANT (COMMERCIAL) UTILITY, PUBLIC DAYCARE CENTER (VACANT) SW 16TH ST I-405 SW 19TH STRAYMOND AVE SWEAST VALLEY RD1000'-0" RADIUS FROM PROJECT SITE R 1 0 0 0 ' - 0 "HWY 167SENECA AVE SWMAPLE AVE SWTAYLOR AVE SWOFFICE PARK WAREHOUSE OFFICE BUILDINGOFFICE BUILDING VACANT (INDUSTRIAL) * STORAGE BUILDING USE NOT LISTED * OFFICE BUILDING USE NOT LISTED * STORAGE USE NOT LISTED * VACANT WAREHOUSE NOTE: PRESENT USES SHOWN ARE FROM COR MAPS DATA SERVICE BUILDING PARKING (COMMERCIAL LOT) HIGH TECH / HIGH FLEX WAREHOUSE WAREHOUSE ROW / UTILITY, ROAD INDUSTRIAL (LIGHT) VACANT (INDUSTRIAL) VACANT (INDUSTRIAL) WAREHOUSE OFFICE BUILDING TAVERN / LOUNGE INDUSTRIAL (GEN PURPOSE) OFFICE BUILDING OFFICE BUILDING OFFICE BUILDING VACANT (COMMERCIAL) VACANT (COMMERCIAL) VACANT (COMMERCIAL) HOTEL / MOTEL HOTEL / MOTEL HOTEL / MOTEL HOTEL / MOTEL OFFICE BUILDING GOVERNMENTAL SERVICE VACANT (COMMERCIAL)VACANT (COMMERCIAL) WAREHOUSEWAREHOUSEVACANT (COMMERCI AL)RI VER / CREEK / STREAMOFFICE PARK VACANT (INDUSTRIAL)VACANT(INDUSTRIAL)CHURCH /WELFARE /RELIG SRVCVACANT(INDUSTRIAL)VACANT(INDUSTRIAL)OFFICE BUILDING AUTO SHOWROOM & LOT WAREHOUSE AUTO SHOWROOM & LOT VACANT (COMMERCIAL)SR 167I-405 I-5PROJECT LOCATION VICINITY LOCATION MAP 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:56:14 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN LAND USE SUMMARY & NEIGHBORHOOD DETAIL MAP GI004 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1" = 100'-0"A2 NEIGHBORHOOD DETAIL MAP NOT APPLICABLE - PROJECT IS NOT RESIDENTIAL OR MIXED USE SPECIAL DEVELOPMENT STANDARDS: SHORELINE MASTER PROGRAM REGULATIONS NOT APPLICABLE 4-3-090 ENVIRONMENTAL REVIEW: CHANGE OF USE IN A BUILDING OVER 4,000 SQUARE FEET WOULD REQUIRE ENVIRONMENTAL REVIEW IN ACCORDANCE WITH THE STATE ENVIRONMENTAL POLICY ACT WAC 197-11-800. IN ADDITION, CRITICAL AREAS ARE PRESENT ON THE SUBJECT SITE. AN ENVIRONMENTAL CHECKLIST HAS BEEN SUBMITTED WITH THE LAND USE APPLICATION. PROPOSALS AND OTHER ALTERATIONS SHALL NOT REDUCE THE EFFECTIVE BASE FLOOD STORAGE VOLUME OF THE FLOODPLAIN ALL NEW CONSTRUCTION AND SUBSTANTIAL IMPROVEMENTS SHALL BE ANCHORED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT OF THE STRUCTURE RESULTING FROM HYDRODYNAMIC AND HYDROSTATIC LOADS INCLUDING THE EFFECTS OF BUOYANCY. PROPOSED EMERGENCY GENERATORS, FUEL TANKS AND UTILITY TRANSFORMERS WILL BE ANCHORED TO HOUSEKEEPING PADS SITE IS MAPPED WITH HIGH SEISMIC HAZARD AREAS, AND SPECIAL FLOOD HAZARD AREA (100 YEAR FLOOD) FEMA ZONE –AE 4-3-050 CRITICAL AREAS: REFUSE AND RECYCLING: SECTION IS APPLICABLE TO "NEW" DEVELOPMENT, HOWEVER EXISTING DEVELOPMENT IS UNDERSIZED AND DOES NOT MEET MINIMUM STANDARDS BY THIS SECTION AND WILL BE EXPANDED IN NON LANDSCAPED AREA. OTHER NONRESIDENTIAL DEVELOPMENTS – MINIMUM SIZE: A MINIMUM OF 3 SF PER 1,000 SF OF BUILDING GROSS FLOOR AREA SHALL BE PROVIDED FOR RECYCLABLES DEPOSIT AREAS A MINIMUM OF 6 SF PER 1,000 SF OF BUILDING GROSS FLOOR AREA SHALL BE PROVIDED FOR REFUSE DEPOSIT AREAS. GROSS BUILDING AREA (KING COUNTY ASSESOR): 200,680 GSF 200,680 SF / 1,000 SF = 200.68 RECYCLABLES 200.68 x 3 = 602 SF REFUSE: 200.68 x 6 = 1,204 SF TOTAL AREA REQUIRED = 1,806 SF EXISTING 319 SF + PROPOSED ADDITIONAL 1,487 SF = 1,806 SF TOTAL AREA 4-4-090 DUMPSTER / RECYCLING COLLECTION AREA: NO CHANGES PROPOSED. NO ADJACENT OR ABUTTING RESIDENTIAL ZONES TO RESTRICT LOCATION. LOADING DOCKS: NO SIGNS PROPOSED AT THIS TIME. FUTURE SIGNAGE TBD AND UNDER SEPARATE PERMIT FOLLOWING 4-4-100 SIGN REGULATIONS 4-4-100 SIGNS: NO CHANGES PROPOSED. PEDESTRIAN CONNECTIONS FROM PRIMARY ENTRANCE TO STREET ARE EXISTING PEDESTRIAN ACCESS: BICYCLE PARKING STANDARDS: FOR LABORATORIES, RESERVED AREA FOR RACKS SHALL BE PROVIDED WITH A MINIMUM AREA OF 2'x6'x7' CLEAR HEIGHT FOR EACH BICYCLE. 5' OF MANUEVERING AREA BETWEEN ROWS SHALL BE PROVIDED. BICYCLE PARKING SHALL BE SECURE EXTENDED USE AND SHALL PROTECT THE ENTIRE BICYCLE AND ITS COMPONENTS AND ACCESSORIES FROM THEFT AND WEATHER. NUMBER OF BICYCLE PARKING SPACES REQUIRED: THE NUMBER OF BICYCLE PARKING SPACES SHALL BE EQUAL 10% OF THE NUMBER OF REQUIRED OFF-STREET VEHICLE PARKING SPACES. 198 x .10 = (19.8) 20 BICYCLE PARKING SPACES 197,446 NET FLOOR AREA (KC ASSESSOR) / 1,000 SF = 198 198 X 1.0 = 198 STALL MINIMUM 198 X 1.5 = 297 STALL MAXIMUM NUMBER OF EXISTING STALLS EXCEED MAXIMUM, REFER TO SITE PLAN FOR PROPOSED AREAS OF REDUCTION, INCLUDING REFUSE/RECYCLING EXPANSION AND MANUEVERING SPACE PROVIDED 299 STALLS + 16 ACCESSIBLE STALLS (6% OVER MAXIMUM) LABORATORIES REQUIRE A MINIMUM OF 1 SPACE UP TO A MAXIMUM 1.5 PER 1,000 SF OF NET FLOOR AREA 4-4-080 PARKING AND LOADING: REFUSE AND RECYCLING: GARBAGE DUMPSTERS, REFUSE COMPACTOR AREAS, AND RECYCLING COLLECTION AREAS MUST BE FENCED OR SCREENED. 4-4-090 GENERAL SCREENING: PROPOSED GENERATOR ELECTRICAL UTILITY YARD EXPANSION SHALL BE SCREENED FROM PUBLIC VIEW. ROOF-TOP EQUIPMENT: PROPOSED EXPANSION OF ROOF-TOP MECHANICAL YARD SHALL BE SCREENED FROM PUBLIC VIEW. IF STRUCTURAL ANALYSIS OF EXISTING ROOF STRUCTURE IS DETERMINED TO NOT BE ABLE TO SAFELY SUPPORT THE REQUIRED SCREENING EQUIPMENT TO BE PAINTED A COLOR TO BE DETERMINED WITH APPROVAL. LOADING, REPAIR, MAINTENANCE AND WORK AREAS: NO SCREENING REQUIRED OUTDOOR STORAGE: NO OUTDOOR STORAGE PROPOSED 4-4-095 SCREENING: NO CHANGE PROPOSED. EXISTING BUILDING IS BELOW MAXIMUM HEIGHT OF 250 FT HEIGHT: LANDSCAPING REQUIREMENTS ARE APPLICABLE DUE TO A CHANGE OF USE THAT REQUIRE IMPROVMENTS EQUAL TO OR GREATER THAN 50% OF ASSESSED PROPERTY VALUATION NO CHANGES PROPOSED. LANDSCAPED AREAS AND TREES TO BE MAINTAINED.4-4-070 LANDSCAPING: CLEAR VISION AREA: NO STRUCTURES PROPOSED IN CLEAR VISION AREA NO CHANGES PROPOSED. EXISTING BUILDING MEET MINIMUM FRONT YARD SETBACK OF 20' NO MAXIMUM FRONT SETBACK REQUIRED. NO SIDE OR REAR YARD SETBACKS REQUIRED SETBACKS: NO RESIDENTIAL PROPOSED & LOT DOES NOT ABUT ANY LOTS DESIGNATED AS RESIDENTIAL DENSITY: 65% MAXIMUM LOT COVERAGE FOR BUILDINGS: NO CHANGE PROPOSED, EXISTING BUILDING LOT COVERAGE IS ± 17.5% LOT COVERAGE: MINIMUM LOT SIZE: NO CHANGE PROPOSED, EXISTING LOT EXCEEDS 25,000 SF MINIMUM LOT DIMENSIONS: DEVELOPMENT STANDARDS FOR COMMERCIAL ZONING CO DESIGNATION:4-2-120B LABORATORIES: RESEARCH, DEVELOPMENT AND TESTING - PERMITTED AS CONDITIONAL USE - ADMINISTRATIVE OFFICES - PERMITTED 4-2-060 PERMITTED USES: COMMERCIAL OFFICE (CO) URBAN DESIGN DISTRICT ‘D’, AND THE EMPLOYMENT AREA COMPREHENSIVE PLAN LAND USE DESIGNATION 4-2-010 ZONING DISTRICT & DESIGNATIONS: PARCEL A: LOT 2, CITY OF RENTON SHORT PLAT NUMBER 431-79, ALSO KNOWN AS VALLEY OFFICE & INDUSTRIAL PARK – SUBDIVISION NO. 1, RECORDED UNDER RECORDING NUMBER 8002269013, IN KING COUNTY, WASHINGTON; EXCEPT THOSE PORTIONS THEREOF CONVEYED TO THE CITY OF RENTON FOR STREET PURPOSED BY DEEDS RECORDED UNDER RECORDING NUMBERS 8007070464, 8008200077 AND 8202160354. KING COUNTY DEPARTMENT OF ASSESSMENTS LEGAL: HILLMANS EARLINGTON GARDENS #1 LOT 2 LESS ST - CITY OF RENTON SP #431-79 REC #8002269013 SD SP DAF - ALL OF VAC BLKS 24 & 31 & VAC VALENTINE AVE BET SD BLKS OF SD SUBD LY S OF S MGN OF SW 16TH ST LESS STS LEGAL DESCRIPTION: 1601 LIND AVE SW RENTON WA 98057 PARCEL NO: 3340404006 SITE ADDRESS & PARCEL: LAND USE SUMMARY 11 P.S. 13 P.S. F L O OD Z O NE "X " F L O OD Z O NE "A E" F L OOD Z ONE "AE " F L OOD Z ONE " X " OWNER: PROVIDENCE HEALTH SYSTEMO/H EO/H E O/H E O/H E LIND AVE. SWS.W. 16TH STREET 10.4'45.0'800707046480070704648007070464 8008200077 40'45' 40'45' N89°34'32"E 32.54' N89°34'32"E 412.79'S01°19'23"W403.71'N89°49'54"W 502.07' S01°22'05"W 5.00' APPROXIMATE FLOOD ZONE BOUNDRY PER FEMA FLOOD MAP (21)(21) (22) (23) (2 2) (2 2 ) (22) (22)(23)(23)(23)(23)(24)(23)(23)(24)(24)(23)(22)(24)(24)(23)(2 2 ) (2 2 )(22)(24)( 2 4 )(24)(22) (22)(23)(23)(22)(24)(21)(24)(23) (22) (26) (26)(22)(22) (22) (2 1 )(25)(25)(25)(25)(25)(25)(20)(20)(25)(2 5 ) (2 5 )(25)(25)ID #85 ID #150 2"DEC (TYP.) 6"DEC ID #101 4"DEC 4"DEC 6"DEC ID #96 8"DEC 6"DEC2"DEC 8"DEC 6"DEC6"DEC6"DEC6"DEC6"DEC8"DEC 8"DEC ID #1 ID #2 ID #3 ID #4 ID #5 ID #6 4"DEC 6"DEC 6"DEC ID #104 ID #103 ID #98 4"DEC2"DECID #48ID #137 4"DEC ID #130 ID #131 ID #132 ID #7 ID #8 ID #9 ID #10 ID #11 ID #12 ID #13 ID #14 ID #15 ID #16 ID #17 ID #18 ID #19 ID #20 ID #21 ID #22 ID #23 ID #24 ID #25 ID #26 ID #27 ID #28 ID #29 ID #30 ID #31 ID #32 ID #33ID #34ID #35ID #36ID #37ID #38ID #39 ID #40 ID #41 ID #42 ID #52 ID #53ID #54ID #55ID #57 ID #58 ID #59 ID #60 ID #61 ID #62 ID #63 ID #64 ID #65 ID #66 ID #67 ID #68 ID #69 ID #70 ID #71 ID #72 ID #73 ID #74 ID #75 ID #76 ID #77 ID #78 ID #79 ID #80 ID #81 ID #83 ID #82 ID #84 ID #86 ID #87 ID #126 ID #88 ID #89 ID #90 ID #91 ID #92 ID #93 ID #95 4"CON ID #116 ID #117 ID #149ID #148ID #147ID #146 ID #145 ID #144ID #133 ID #135 ID #134 ID #136 ID #127 ID #128 ID #129 ID #138 ID #139 ID #141 ID #142 ID #143 ID #51 ID #97 ID #115 ID #114 ID #106 ID #107 ID #102 ID #99 ID #100 ID #113 ID #108 ID #109 ID #110 ID #112 ID #111 ID #118ID #119ID #121ID #125ID #124ID #122ID #153ID #47ID #46ID #151ID #50ID #123ID #120ID #43 ID #44 ID #45 ID #15239' DWY30' DWY 6'CONC. WALK 6'CONC. WALK 6'CONC. WALKD D D D D S D D D D 21.65 19.6 3 19.94 19.44 19.30 25.08 22.65 N89°34'32"E 1027.81'N01°19'23"EN01°20'40"E460.23'PROJECT SITE: 1601 LIND AVE SW PARCEL NO: 3340404006 FLOOR NET AREA (EXISTING): 197,446 SF APPROX LOT AREA: 229,238 SF (5.263 AC) PRIMARY ENTRANCE ENTRANCE / EXIT ENTRANCE / EXIT ENTRANCE / EXIT105'-0"PROPERTY LINENOTE: • ALL LANDSCAPING AND TREES ARE EXISTING AND WILL BE RETAINED, NO PROPOSED CHANGES • LANDSCAPE DIAGRAM TO DEMONSTRATE COMPLIANCE WITH SITE PLAN REVIEW CRITERIA FOR CONDITIONAL USE PERMIT 1,487 SF EXISTING FFE = 25.01' 77'-3"19'-3"46'-6"6'-4"6'-0"12'-8"6'-0"6'-4"5'-0"13'-0"FEMA BASE FLOOD ELEVATION = 20' GENERATOR GENERATOR 12'-10"10'-0"EXISTING LANDSCAPE MEETS STREET FRONTAGE LANDSCAPING REQUIRED ALONG PUBLIC STREET (RMC 4-4-070 F.1) EXISTING STREET TREES, REFER TO TREE RETENTION AUDIT FOR SIZE AND SPECIES EXISTING PERIMETER PARKING LOT & STREET TREES, REFER TO TREE RETENTION AUDIT FOR SIZE AND SPECIES 14,360 SF INTERIOR PARKING LOT LANDSCAPE AREA 3 4 2 1 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 37 38 39 40 41 42 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 85 84 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 181 182 183 184 185 186 187 188 189 239 238 240 241 242 243 244 245 246 167 168 169 170 171 172 173 174 175 176 177 178 179 180 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 280281282283284285286287288289290291 304 303 302 301 298 297 296 295 294 293 292 247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279 305306 308 307 309310 311312 314 313 315 300 299 HATCHED AREA: 10 STALLS RESERVED FOR COURIER/ VENDOR 12'-10" EXISTING PERIMETER PARKING LOT LANDSCAPING AT LEAST 10' IN WIDTH 484'-10" STREET FRONTAGE 443'-6" STREET FRONTAGELAYOUT LEGEND EXISTING INTERIOR PARKING LOT LANDSCAPING EXISTING LANDSCAPING AREA EXISTING DECIDUOUS TREES (REFER TO ARBORIST REPORT) EXISTING CONIFEROUS TREES (REFER TO ARBORIST REPORT) 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:56:16 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN LANDSCAPE DIAGRAM GI005 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 A1 LANDSCAPE DIAGRAM INTERIOR PARKING LOT LANDSCAPING RMC 4-4-070 H.5.b MINIMUM 1 SHRUB PER 20 SF OF LANDSCAPED AREA 14,360 SF / 20 = 664 SHRUBS REQUIRED EXISTING MATURE SHRUBS COVER MAJORITY OF INTERIOR PARKING LOT LANDSCAPED AREA INTERIOR PARKING LOT LANDSCAPING RMC 4-4-070 H.5.a MINIMUM 1 TREE FOR EVERY 6 PARKING STALLS TOTAL OF 315 PARKING STALLS 315 / 6 = 53 TREES REQUIRED ±60 EXISTING PERIMETER PARKING LOT LANDSCAPING RMC 4-4-070 H.4.b MINIMUM 1 SHRUB PER 20 SF OF LANDSCAPED AREA EXISTING MATURE SHRUBS COVER MAJORITY OF PERIMETER PARKING LOT LANDSCAPED AREA PERIMETER PARKING LOT LANDSCAPING RMC 4-4-070 H.4.a MINIMUM 1 TREE PER 30 LINEAL FT OF STREET FRONTAGE TOTAL OF 928' - 4" OF STREET FRONTAGE 928.3 / 30 = 31 ±54 EXISTING MINIMUM AMOUNT OF INTERIOR PARKING LOT LANDSCAPING RMC 4-4-070 F.6.b MINIMUM LANDSCAPE AREA REQUIRED: 100 OR MORE PARKING STALLS @ 35SF/ PARKING SPACE TOTAL OF 315 PARKING STALLS 315 X 35 = 11,025 SF REQUIRED 14,360 SF EXISTING ALL LANDSCAPING AND TREES ARE EXISTING AND WILL BE RETAINED, NO PROPOSED CHANGES PARKING LOT LANDSCAPE REQUIREMENTS 2 B C D 1 1 2 3 3 9 S107 REINFORCING PER PLAN COMPACTED SUBGRADE 5/8" MINUS CRUSHED ROCK CAPILLARY BREAK MATERIAL /3 S107 GENERATOR PER PLAN AND ELECTRICAL DRAWINGS GENERATOR BASE RAIL ANCHOR GENERATOR TO SLAB WITH STAINLESS STEEL EXPANSION ANCHORS AT MFR'S REQUIRED LOCATIONS 4' - 0"2' - 0"TOP OF WALL 15' -0" CAP AT TOP OF WALL PER ARCH. BOND BEAM AT GRADE, TOP OF WALL, AND 48" OC. BETWEEN, REINFORCE WITH (2) #5 (2) #6 AT 16" OC. HOOKED DOWELS TO MATCH WALL VERTS. THICKENED SLAB AT EDGE OF GENERATOR YARD SLAB ON GRADE PER PLAN, EXTEND REINFORCING INTO THICKENED SLAB REINFORCE BOTTOM OF THICKENED SLAB WITH (5) #6 LONG AND #4 AT 32" TRANSVERSE 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: LAB CONSULTING MANAGER: STRUCTURAL ENGINEER: MEP: LAB PLANNING: REVISIONS MARK DATE DESCRIPTIONB SHEET OF 250 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 NOT FOR CONSTRUCTION 3/7/2023 3:32:33 PMAutodesk Docs://102987.00 - UW DLMP R22/STRU_UW DLMP_TI.rvt102987.00 JT GENERATOR YARD PLAN AND DETAILS S107 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 13, 223 SCALE: 3/16" = 1'-0"7 STRUCTURAL PLAN - GENERATOR YARD 1 8" SLAB ON GRADE WITH #4 AT 16" OC. EACH WAY, TOP AND BOTTOM. PROVIDE THICKENED SLAB AT EDGE PER SECTION REFERENCED ON PLAN. 2 12" REINFORCED AND SLOID GROUTED CMU WALL. REINFORCE WITH (2) #6 AT 16" OC. AND BOND BEAMS WITH (2) #5 AT GRADE, TOP OF WALL, AND 48" OC. BETWEEN. TOP OF WALL EQUALS 15'-0" ABOVE SLAB. 3 GENERATOR PER ELECTRICAL DRAWINGS. ANCHOR TO SLAB PER DETAIL KEYNOTES:GENERAL NOTES: A. SEE ARCHITECTURAL AND / OR SITE DRAWINGS FOR DIMENSIONS NOT SHOWN. B. APPROXIMATE GENERATOR PAD ELEVATIO EQUALLS 24.75'. SCALE: 1" = 1'-0"4 TYP. SLAB ON GRADE SCALE: 1" = 1'-0"3 GENERATOR ANCHORAGE SCALE: 1" = 1'-0"9 MASONRY WALL SECTION F L O OD Z O NE "X " F L O OD Z O NE "A E" F L OOD Z ONE "AE " F L OOD Z ONE " X " OWNER: PROVIDENCE HEALTH SYSTEMO/H EO/H E O/H E O/H E LIND AVE. SWS.W. 16TH STREET 10.4'45.0'800707046480070704648007070464 8008200077 40'45' 40'45' N89°34'32"E 32.54' N89°34'32"E 412.79'S01°19'23"W403.71'N89°49'54"W 502.07' S01°22'05"W 5.00'20.0'20.0' FRONT SETBACK SIDE SETBACK CONC WALK IS 1.32' OUTSIDE EASEMENT APPROXIMATE FLOOD ZONE BOUNDRY PER FEMA FLOOD MAP (21)(21) (22) (23) (2 2) (2 2 ) (22) (22)(23)(23)(23)(23)(24)(23)(23)(24)(24)(23)(22)(24)(24)(23)(2 2 ) (2 2 )(22)(24)( 2 4 ) (24)(24)(22) (22)(23)(23)(22)(24)(21)(24)(23) (22) (26) (26)(22)(22) (22) (2 1 )(25)(25)(25)(25)(25)(25)(20)(20)(25)(2 5 ) (2 5 )(25)(25)ID #85 ID #150 2"DEC (TYP.) 6"DEC ID #101 4"DEC 4"DEC 6"DEC ID #96 8"DEC 6"DEC2"DEC 8"DEC 6"DEC6"DEC6"DEC6"DEC6"DEC8"DEC 8"DEC ID #1 ID #2 ID #3 ID #4 ID #5 ID #6 4"DEC 6"DEC 6"DEC ID #104 ID #103 ID #98 4"DEC2"DECID #48ID #137 4"DEC ID #130 ID #131 ID #132 ID #7 ID #8 ID #9 ID #10 ID #11 ID #12 ID #13 ID #14 ID #15 ID #16 ID #17 ID #18 ID #19 ID #20 ID #21 ID #22 ID #23 ID #24 ID #25 ID #26 ID #27 ID #28 ID #29 ID #30 ID #31 ID #32 ID #33ID #34ID #35ID #36ID #37ID #38ID #39 ID #40 ID #41 ID #42 ID #52 ID #53ID #54ID #55ID #57 ID #58 ID #59 ID #60 ID #61 ID #62 ID #63 ID #64 ID #65 ID #66 ID #67 ID #68 ID #69 ID #70 ID #71 ID #72 ID #73 ID #74 ID #75 ID #76 ID #77 ID #78 ID #79 ID #80 ID #81 ID #83 ID #82 ID #84 ID #86 ID #87 ID #126 ID #88 ID #89 ID #90 ID #91 ID #92 ID #93 ID #95 4"CON ID #116 ID #117 ID #149ID #148ID #147ID #146 ID #145 ID #144ID #133 ID #135 ID #134 ID #136 ID #127 ID #128 ID #129 ID #138 ID #139 ID #141 ID #142 ID #143 ID #51 ID #97 ID #115 ID #114 ID #106 ID #107 ID #102 ID #99 ID #100 ID #113 ID #108 ID #109 ID #110 ID #112 ID #111 ID #118ID #119ID #121ID #125ID #124ID #122ID #153ID #47ID #46ID #151ID #50ID #123ID #120ID #43 ID #44 ID #45 ID #152CROSSWALKYELLOWSTRIPESTOP BAR LOADING DOCK STRIPE ENTRANCE SIGN "RIGHTTURN ONLY""BUS STOP" "RIGHT TURN ONLY""NO RACINGZONE"""NOTRESSPASSING""FAA" SIGN "15 MIN PARKING" HANDICAP PARKING "H/C""VAN POOL""H/C" "BUS STOP" "BUS STOP""FLOOD EVAC. ROUTE" (6) "H/C PARKING" SIGNS STREET SIGN "NO TRESPASSING" SIGN "CCTV SURVEILANCE" "VISITOR/ BUILDING ENGINEER PARKING ONLY" CRW CRW CRW39' DWY30' DWY 6'CONC. WALK 6'CONC. WALK 6'CONC. WALKSPEED BUMP SPEED BUMP SPEED BUMP17 P.S.24 P.S 20 P.S. 17 P.S.17 P.S. 8 P.S. 21 P.S 16 P.S. 14 P.S. 16 P.S. 17 P.S. 16 P.S. 9 P.S. 7 P.S. 12 P.S. 13 P.S.11 P.S."MAIL TRUCK PARKING ONLY" 33 P.S. NO PARKING 18 P.S. 2 P.S. 2 P.S. D D D D D S D D D D 23.06 21.65 21.23 21.3 0 21.2 9 23.48 19.6 3 19.94 19.44 19.30 25.08 22.65 23.51 23.67 23.53 N89°34'32"E 1027.81'N01°19'23"EN01°20'40"E460.23'PROJECT SITE: 1601 LIND AVE SW CURRENT USES (EXISTING BUILDING): LABORATORIES: RESEARCH, DEVELOPMENT AND TESTING - LEVEL 1 OFFICES, GENERAL - LEVELS 1-5 PROPOSED USES: PRINCIPLE USE: LABORATORIES: RESEARCH, DEVELOPMENT AND TESTING - LEVELS 1-5 ACCESSORY USE: OFFICE, GENERAL - LEVELS 1-5 PARCEL NO: 3340404006 FLOOR NET AREA (EXISTING): 197,446 SF APPROX LOT AREA: 229,238 SF (5.263 AC) PRIMARY ENTRANCE ENTRANCE / EXIT ENTRANCE / EXIT ENTRANCE / EXIT EXISTING GENERATOR w/ FUEL TANK REMOVED EXISTING GENERATOR REMOVED EXISTING FUEL TANK REMOVED EXISTING ELECTRICAL TRANSFORMER REMOVED EXISTING FENCE ENCLOSURE PROPERTY LINEEXISTING REFUSE, COMPOST & RECYLCING LOCATION NOTE: ALL INFORMATION ON SITE PLAN REQUIRES VERIFICATION 319 SF 1,487 SF PROPOSED ADDITIONAL REFUSE & RECYLCING LOCATION WITH 6' FENCE ENCLOSURE (4-4-090.C9) EXISTING FFE = 25.01' (11 BIKES) HATCHED AREA: 10 STALLS RESERVED FOR COURIER/ VENDOR 20 LOCKABLE BIKE LOCKERS. 12 SINGLE & 4 DOUBLE UNITS AS102 A5 FEMA BASE FLOOD ELEVATION = 20' AS102 A2 GENERATOR GENERATOR 3 4 2 1 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 37 38 39 40 41 42 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 85 84 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 181 182 183 184 185 186 187 188 189 239 238 240 241 242 243 244 245 246 167 168 169 170 171 172 173 174 175 176 177 178 179 180 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 280281282283284285286287288289290291 304 303 302 301 298 297 296 295 294 293 292 247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279 305306 308 307 309310 311312 314 313 315 300 299 PSE SUB-STATION PARKING LOT (COMMERCIAL) 77'-3"19'-3"46'-6"6'-4"6'-0"12'-8"6'-0"6'-4"5'-0"13'-0"37'-0" 24'-1"183'-2"250'-4"223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:56:09 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN ARCHITECTURAL SITE PLAN AS101-A2 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1" = 20'-0"A1 ARCHITECTURAL SITE PLAN DN D 22.10 22.24 22.8322.42 22.24 23.02 22.6322.61 23.15 23.06 2 3.6 8 23.58 23.51 23.14 23.17 22.90 22.88 22.91 22.75 23.38 22.29 2 2.8 6 2 5.10 24.64 24.77 24.95 26.51 23.44 2 3.4 6 24.86 2 4.7 2 26.47 2 4.4 6 2 4.5 8 26.43 22.94 22.55 22.30 2 2.8 2 24.50 25.00 2 4.3 0 23.31 N01°20'40"E460.23'11 P.S. 13 P.S.F L OOD Z ONE "AE " F L OOD Z ONE " X " (23) (22)(23)(2 1 )6"DEC6"DEC8"DEC 8"DEC ID #1 ID #2 ID #3 ID #4 SPEED BUMPNO PARKING 18 P.S. AE201 A1 2 A D E F 1 B C PUBLIC UTILITIES EASEMENT PUBLIC UTILITIES EASEMENTPUBLIC UTILITIES EASEMENTEASEMENT PUBLIC UTILITIES PSE EASEMENT PSE EASEMENTPSE EASEMENT48" CORRUGATED METAL PIPE EXISTING CATCH BASIN 48" CORRUGATED PIPE (25')(24') (23') (24' ) (22' ) (23' ) (24') (25') (23') TO COMBUSTIBLE 10'-0" CLEAR TO COMBUSTIBLE10'-0" CLEAR10" WATER MAIN 10" WATER MAIN 3'-0" CLEAR TO NON-COMBUSTIBLE MAIN ELECTRICAL ROOM NON-COMBUSTIBLE RECLADDING6'-0"4'-1 1/8"4'-1"7'-4 5/8" GENERATOR & FUEL TANK GENERATOR & FUEL TANK FUEL FILL STATION 3'-6"3'-4"8'-0"8'-0"3'-4"4'-0" 4'-4 5/8"MTS 1 MTS 2 34'-9 7/8"32'-1 3/8"EXISTING REFUSE, COMPOST & RECYLCING LOCATION - NO PROPOSED CHANGES 319 SF 1,487 SF PROPOSED ADDITIONAL REFUSE & RECYLCING LOCATION WITH 6' FENCE ENCLOSURE (4-4-090.C9) HATCHED AREA: 10 STALLS RESERVED FOR COURIER/ VENDOR 20 LOCKABLE BIKE LOCKERS. 12 SINGLE & 4 DOUBLE UNITS 77'-3"19'-3"46'-6"310 309 307 308 306 305 279 RESTRIPE AREA FOR NO PARKING 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:56:11 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN ARCHITECTURAL SITE PLANS - ENLARGED AS102 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A5 ARCHITECTURAL SITE PLAN -ELECTRICAL YARD 1/8" = 1'-0"A2 ARCHITECTURAL SITE PLAN -REFUSE/RECYCLE 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 B B C C 36,681 SF AREA OF WORK ALL GYPSUM BOARD AT PERIMETER EXTERIOR WALLS TO REMAIN, TYP EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N., TYP DEMOLITION PLAN NOTES 1. ALL INFORMATION SHOWN ON DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEES OF ACCURACY. FIELD VERIFY ALL CONDITIONS. 2. IN GENERAL, THE FULL EXTENT OF THIS WORK INCLUDES ALL DEMOLITION NECESSARY FOR THE INSTALLATION OF NEW CONSTRUCTION UNDER SEPARATE PERMIT(S). DEMOLITION DRAWINGS ONLY SHOW THE GENERAL SCOPE OF DEMOLITION. 3. REMOVE ALL NON-STRUCTURAL PARTITIONS, FLOORING, BASE MATERIALS, CASEWORK AND FINISHES IN AREA OF WORK. 4. REMOVE ALL CEILINGS AND LIGHTING THROUGHOUT AREA OF WORK. 5. REMOVE MECHANICAL, ELECTRICAL , DATA AND PLUMBING ASSOCIATED WITH DEMOLITION OF PARTITIONS AND CEILINGS IN AREA OF WORK. 6. EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES WHICH SERVE OTHER EXISTING OCCUPIED AREAS MUST REMAIN AND SHALL BE PROTECTED DURING THE CONSTRUCTION. 7. ALL RAIN LEADERS TO REMAIN IN PLACE 8. COORDINATE DEMOLITION OUTSIDE THE PROJECT AREA TO THE POINT OF CONNECTION FOR MECHANICAL, ELECTRICAL, DATA AND PLUMBING. 9. EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N. 10. ALL PERIMETER GYPSUM BOARD FINISH TO REMAIN AT EXTERIOR WALLS 11. SALVAGE EXIT SIGNS, FIRE EXTINGUISHERS AND CABINETS AND SIGNAGE IF PRESENT FOR REUSE AND REINSTALLATION. DEMOLITION LEGEND ELEMENTS TO BE DEMOLISHED OR REMOVED AREA NOT IN SCOPE 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:44 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F2 ARCHITECTURAL DEMOLITION PLAN AD102-A1 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F2 DEMOLITION PLAN 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 B B C C 36,681 SF AREA OF WORK ALL GYPSUM BOARD AT PERIMETER EXTERIOR WALLS TO REMAIN, TYP EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N., TYP DEMOLITION PLAN NOTES 1. ALL INFORMATION SHOWN ON DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEES OF ACCURACY. FIELD VERIFY ALL CONDITIONS. 2. IN GENERAL, THE FULL EXTENT OF THIS WORK INCLUDES ALL DEMOLITION NECESSARY FOR THE INSTALLATION OF NEW CONSTRUCTION UNDER SEPARATE PERMIT(S). DEMOLITION DRAWINGS ONLY SHOW THE GENERAL SCOPE OF DEMOLITION. 3. REMOVE ALL NON-STRUCTURAL PARTITIONS, FLOORING, BASE MATERIALS, CASEWORK AND FINISHES IN AREA OF WORK. 4. REMOVE ALL CEILINGS AND LIGHTING THROUGHOUT AREA OF WORK. 5. REMOVE MECHANICAL, ELECTRICAL , DATA AND PLUMBING ASSOCIATED WITH DEMOLITION OF PARTITIONS AND CEILINGS IN AREA OF WORK. 6. EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES WHICH SERVE OTHER EXISTING OCCUPIED AREAS MUST REMAIN AND SHALL BE PROTECTED DURING THE CONSTRUCTION. 7. ALL RAIN LEADERS TO REMAIN IN PLACE 8. COORDINATE DEMOLITION OUTSIDE THE PROJECT AREA TO THE POINT OF CONNECTION FOR MECHANICAL, ELECTRICAL, DATA AND PLUMBING. 9. EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N. 10. ALL PERIMETER GYPSUM BOARD FINISH TO REMAIN AT EXTERIOR WALLS 11. SALVAGE EXIT SIGNS, FIRE EXTINGUISHERS AND CABINETS AND SIGNAGE IF PRESENT FOR REUSE AND REINSTALLATION. DEMOLITION LEGEND ELEMENTS TO BE DEMOLISHED OR REMOVED AREA NOT IN SCOPE 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:46 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F3 ARCHITECTURAL DEMOLITION PLAN AD103-A1 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F3 DEMOLITION PLAN 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 B B C C 36,681 SF AREA OF WORK ALL GYPSUM BOARD AT PERIMETER EXTERIOR WALLS TO REMAIN, TYP EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N., TYP DEMOLITION PLAN NOTES 1. ALL INFORMATION SHOWN ON DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEES OF ACCURACY. FIELD VERIFY ALL CONDITIONS. 2. IN GENERAL, THE FULL EXTENT OF THIS WORK INCLUDES ALL DEMOLITION NECESSARY FOR THE INSTALLATION OF NEW CONSTRUCTION UNDER SEPARATE PERMIT(S). DEMOLITION DRAWINGS ONLY SHOW THE GENERAL SCOPE OF DEMOLITION. 3. REMOVE ALL NON-STRUCTURAL PARTITIONS, FLOORING, BASE MATERIALS, CASEWORK AND FINISHES IN AREA OF WORK. 4. REMOVE ALL CEILINGS AND LIGHTING THROUGHOUT AREA OF WORK. 5. REMOVE MECHANICAL, ELECTRICAL , DATA AND PLUMBING ASSOCIATED WITH DEMOLITION OF PARTITIONS AND CEILINGS IN AREA OF WORK. 6. EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES WHICH SERVE OTHER EXISTING OCCUPIED AREAS MUST REMAIN AND SHALL BE PROTECTED DURING THE CONSTRUCTION. 7. ALL RAIN LEADERS TO REMAIN IN PLACE 8. COORDINATE DEMOLITION OUTSIDE THE PROJECT AREA TO THE POINT OF CONNECTION FOR MECHANICAL, ELECTRICAL, DATA AND PLUMBING. 9. EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N. 10. ALL PERIMETER GYPSUM BOARD FINISH TO REMAIN AT EXTERIOR WALLS 11. SALVAGE EXIT SIGNS, FIRE EXTINGUISHERS AND CABINETS AND SIGNAGE IF PRESENT FOR REUSE AND REINSTALLATION. DEMOLITION LEGEND ELEMENTS TO BE DEMOLISHED OR REMOVED AREA NOT IN SCOPE 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:47 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F4 ARCHITECTURAL DEMOLITION PLAN AD104-A1 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F4 DEMOLITION PLAN 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 B B C C 36,681 SF AREA OF WORK ALL GYPSUM BOARD AT PERIMETER EXTERIOR WALLS TO REMAIN, TYP EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N., TYP DEMOLITION PLAN NOTES 1. ALL INFORMATION SHOWN ON DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEES OF ACCURACY. FIELD VERIFY ALL CONDITIONS. 2. IN GENERAL, THE FULL EXTENT OF THIS WORK INCLUDES ALL DEMOLITION NECESSARY FOR THE INSTALLATION OF NEW CONSTRUCTION UNDER SEPARATE PERMIT(S). DEMOLITION DRAWINGS ONLY SHOW THE GENERAL SCOPE OF DEMOLITION. 3. REMOVE ALL NON-STRUCTURAL PARTITIONS, FLOORING, BASE MATERIALS, CASEWORK AND FINISHES IN AREA OF WORK. 4. REMOVE ALL CEILINGS AND LIGHTING THROUGHOUT AREA OF WORK. 5. REMOVE MECHANICAL, ELECTRICAL , DATA AND PLUMBING ASSOCIATED WITH DEMOLITION OF PARTITIONS AND CEILINGS IN AREA OF WORK. 6. EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES WHICH SERVE OTHER EXISTING OCCUPIED AREAS MUST REMAIN AND SHALL BE PROTECTED DURING THE CONSTRUCTION. 7. ALL RAIN LEADERS TO REMAIN IN PLACE 8. COORDINATE DEMOLITION OUTSIDE THE PROJECT AREA TO THE POINT OF CONNECTION FOR MECHANICAL, ELECTRICAL, DATA AND PLUMBING. 9. EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N. 10. ALL PERIMETER GYPSUM BOARD FINISH TO REMAIN AT EXTERIOR WALLS 11. SALVAGE EXIT SIGNS, FIRE EXTINGUISHERS AND CABINETS AND SIGNAGE IF PRESENT FOR REUSE AND REINSTALLATION. DEMOLITION LEGEND ELEMENTS TO BE DEMOLISHED OR REMOVED AREA NOT IN SCOPE 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:49 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F5 ARCHITECTURAL DEMOLITION PLAN AD105-A1 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F5 DEMOLITION PLAN DN 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 EXISTING MECHANICAL SCREEN & SUPPORT STRUCTURE TO BE REMOVED MECHANICAL EQUIPMENT AND CURBS TO BE REMOVED, TYP. REMOVE ELEVATOR HOISTWAY RELIEF VENTS HATCHED AREA OF ROOF DEMOLITION FOR MECHANICAL SHAFTS, TYP. REMOVE SATELLITE DISHES AND OTHER MISCELLANEOUS EXTRANEOUS EQUIPMENT, TYPICAL B B C C DEMOLITION PLAN NOTES 1. IN GENERAL, THE FULL EXTENT OF THIS WORK INCLUDES ALL DEMOLITION NECESSARY FOR THE INSTALLATION OF NEW CONSTRUCTION. DEMOLITION DRAWINGS ONLY SHOW THE GENERAL SCOPE OF DEMOLITION. COORDINATE DEMOLITION OUTSIDE THE PROJECT AREA TO THE POINT OF CONNECTION FOR MECHANICAL, ELECTRICAL AND PLUMBING. 2. EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES WHICH SERVE OTHER EXISTING OCCUPIED AREAS MUST REMAIN AND SHALL BE PROTECTED DURING THE CONSTRUCTION. 3. REMOVE ALL CEILINGS AND LIGHTING THROUGHOUT AREA OF WORK. 4. EXISTING GYPSUM BOARD FIRE-PROOFING COLUMN ENCLOSURES TO REMAIN AT ALL COLUMNS U.O.N. 5. RESTROOMS: DEMOLISH ALL FIXTURES, TOILET PARTITIONS, FINISHES AND ACCESSORIES. ROUGH PLUMBING TO REMAIN 6. STAIRWELLS: DEMO ALL GUARDRAILS, FINISHES & LIGHTINGROOF DEMOLITION NOTES 1. DEMOLISH EXISTING MEP TO MEET PROGRAM REQUIREMENTS. DEMOLITION LEGEND ELEMENTS TO BE DEMOLISHED OR REMOVED NEW FLOOR OR ROOF OPENINGS EQUIPMENT TO BE REMOVED 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:51 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN ROOF ARCHITECTURAL DEMOLITION PLAN AD106 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 R1 DEMOLITION PLAN ALUMINUM CONCRETE GLASS RIGID INSULATION BRICK IN SECTION CONCRETE MASONRY UNIT EARTH GYPSUM / PLASTER STEEL STONE BATT INSULATION PRECAST GRAVEL SAND WOOD - SOLID PLYWOOD BRICK CULTURED STONE EXTERIOR COMPOSITE PANEL BLOCKING SHIM GRASS MATERIAL LEGEND SYMBOLOGY LEGEND BUILDING SECTION NUMBER SHEET ON WHICH SECTION IS DRAWN SHEET NUMBER SEQUENCE AE 1 01 SHEET NUMBER SHEET TYPE DISCIPLINE EL: +10'-0" SPOT ELEVATION LEVEL DATUM MATCHLINE REFERENCECENTERLINE SYMBOL PARTITION TAG - WITH STC CEILING TAG REVISION CALLOUT AND CLOUD CODED NOTE TAG WINDOW TAG DOOR TAG FURNITURE TAG FINISH TAG ROOM TAG NORTH ARROW GRID BUBBLES VIEW TITLE VIEW TITLE ON SHEET NUMBER ON SHEET EXISTING GRID BUBBLES SCALE GRAPHIC SCALE ELEVATION REFERENCE INTERIOR ELEVATION REFERENCE BUILDING SECTION WALL SECTION DETAIL SECTION NUMBER DETAIL SECTION ALIGN SYMBOL INDICATES SIMILAR OR OPPOSITE HAND CONDITION PLAN NORTH 0'8'16'32'64' SCALE: 1/16" = 1'-0" # ## # A101 A1 A101 A1 REF A1REF A1 REF A1 REFA101 A1 SIM SHEET ON WHICH DETAIL IS DRAWN 101000 1 ALIGN 1 WALL SECTION NUMBER SHEET ON WHICH SECTION IS DRAWN /MATCHLINE SEE: 1 A101 A1 A101 SIM A1 A101 SIM DETAIL CALLOUT SHEET ON WHICH DETAIL IS DRAWN A101 A1 SIM DETAIL SECTION NUMBER A NAME ELEVATION CPT-01 ACP-1 1' -0" A.F.F. A1 VIEW TITLE 1/8" = 1'-0" A1 A101 SIMOPP ROOM NAME 38-999 B 1 6 45 202M HW D Extra ShelfCASEWORK TAG FIXTURE AND EQUIPMENT TAG 00000 PARTITION TAG - NO STC B 1 6 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:52 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN ARCHITECTURAL NOTES AND SYMBOLS AE001 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 (E) EXISTING (N) NEW (R) REUSED, RELOCATED @ AT ACC ACCESSIBLE ACP ACOUSTIC CEILING PANEL(S) AFF ABOVE FINISHED FLOOR ALT ALTERNATE, ALTERATION BLDG BUILDING BOT BOTTOM BW BOTTOM OF WALL CG CORNER GUARD CH COAT HOOK CJ CONTROL JOINT CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT(S) CTR CENTER CU CUBIC DEG DEGREE DIAG DIAGONAL DIAM DIAMETER DIM DIMENSION DISP DISPENSER DN DOWN DW DISHWASHER EJ EXPANSION JOINT EL ELEVATION ELEV ELEVATOR, ELEVATION EQ EQUAL EXT EXTERIOR FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FIN FINISH FLR FLOORLINE, FLOOR FO FACE OF FS FLOOR SINK FT FOOT, FEET GA GAUGE GB GRAB BAR GFRP GLASS FIBER REINFORCED PLASTIC GL GLASS GLI GLASS (INTERIOR) GLU-LAM GLUE LAMINATED GYP BD GYPSUM BOARD HB HOSE BIB HD HAND DRYER HEX HEXAGONAL HM HOLLOW METAL HORIZ HORIZONTAL HT HEIGHT HVAC HEATING VENTILATION AND AIR CONDITIONING ID INSIDE DIAMETER IGU INSULATED GLASS UNIT IN INCH INT INTERIOR J-BOX JUNCTION BOX JT JOINT LF LINEAR FOOT MAX MAXIMUM MIN MINIMUM MO MASONRY OPENING NA NOT APPLICABLE NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OPP OPPOSITE ORD OVERFLOW ROOF DRAIN ABBREVIATIONS PL PLATE, PROPERTY LINE PT POINT R RADIUS, RISER RD ROOF DRAIN REV REVISION RO ROUGH OPENING SF SQUARE FEET SIM SIMILAR SQ SQUARE SSG STRUCTURAL SEALANT GLAZED STD STANDARD T TOP TO TOP OF TOC TOP OF CURB, TOP OF CONCRETE TOS TOP OF STEEL, TOP OF SLAB TOW TOP OF WALL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD WT WEIGHT YD YARD ELEC. PANEL ELEC. PANEL ELEC. PANEL LAB 3 PANTHERS & ARCH VESTIBULE HALLWAY OPEN OFFICE BF W/R OFFICE1 OFFICE 2 STORAGE SPACE MAIN ELECTRICAL HALLWAY FITNESS RESTROOM 4 RESTROOM 3 HALLWAY LAB HALLWAY POST-PCR ROOM LOBBY SPACE SERVICE ACCESS HALLWAY LAB 4 ALINITY LAB HALLWAY OFFICE STORAGE LOADING SPACE LAB 2 COBAS LAB CORRIDOR LAB HALLWAY LOADING DOCK LAB CORRIDOR STORAGE SPACE ACCESSIONING HALLWAY OFFICE OFFICELAB CORRIDOR STORAGE LUNCH ROOM FREEZER STORAGE EXISTING COMM ROOM COMM. ROOM STAIRS 2 RESTROOM 2 RESTROOM 1 STAIRS 1 ENGINEER'S OFFICE SPRINKLER ROOM ELEVATOR LOBBY VESTIBULE LUNCH ROOM BACKROOM VESTIBULE SUPERVISOR'S OFFICE COMM ROOM LAB HALLWAY SERVICE ACCESS HALLWAY CONFERENCE ROOM COMM RM HALLWAY UTILITY UTILITY ACCESSIONING PROBLEM RESOLUTION MECH. LAB 5 EXISTING TO REMAIN EXISTING TO REMAIN EXISTING TO REMAIN EXISTING RAMP 115 100 HW1 102 103 105 106 104 107 HW2 108 109B 109A 129 HW5 HW7 111 101 HW4A 112 HW8 113 114 LD-2 116 HW10 HW12 LD-1 HW9 120 HW13 138 139 HW13 121 122 124 127 140 ST-2 134 133 130 ST-1 132 131 136 135 HW3 HW6 123 HW14 118 137 HW11 HW4B 128 HW15 119B 119A EXISTING TO REMAIN 117 118A 141 110 LINE OF EXISTING CANOPY DN UP DN DN DN 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 22'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"72'-0"28'-0"24'-0"24'-0"24'-0"-1'-6"0" 0" DN DN (9) BIKE RACKS FIRE PUMP & RISER ROOM B B C C 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:53 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F1 FLOOR PLAN AE101-A1 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F1 FLOOR PLAN FOR REFERENCE ONLY UP DN DN UP AE202 D1 AE201 D1 AE201 A1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 A2 AE301 A2 AE301 AE202A1 D1 AE301 D1 AE301 22'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"72'-0"28'-0"24'-0"24'-0"24'-0"REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS 2-HOUR RATED GLASS 2-HOUR RATED GLASS REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS B B C C ELEVATOR #1 SERVICE ELEVATOR ELEVATOR #2 ELEVATOR #3 CUSTODIAL ELEVATOR VESTIBULE PLUMBING AND GAS STORAGE RESTROOM RESTROOM MECHANICAL SHAFT STORAGEMECHANICAL SHAFT STAIR A STAIR B SHAFT SHAFT SHAFTSHAFT SAMPLE RECEIVING STORAGE SERVICE ELEVATOR ELECTRICAL ROOM PLUMBING RISER ELECTRICAL RISER MECH SHAFTMECH SHAFT ELEVATOR VESTIBULE HAZARDOUS MATERIAL STORAGE SAMPLE RECIEVING LOCKERS / COATS LOCKERS / COATS STORAGEAUTOCLAVE & GLASS WASH ELECTRICAL ROOM PLUMBING RISER ELECTRICAL RISER MECH SHAFTMECH SHAFT IDF LOCKERS / COATS LOCKERS / COATS CONTROL AREA 3 CONTROL AREA 2 PHONE PHONE TOUCHDOWNS HUDDLE FOCUS FOCUS BREAK / PANTRY RESTROOM RESPITE MOTHER'S HUDDLE HUDDLE HUDDLE FOCUS FOCUS CONTROL AREA 1 SERVICE CORRIDOR FLOOR PLAN GENERAL NOTES 1. RESTROOMS: NEW COUNTERS, FIXTURES, TOILET PARTITIONS, FINISHES AND ACCESSORIES. 2. STAIRWELLS: NEW PAINT, FINISHES, LIGHTING & GUARDRAILS (CODE COMPLIANT) 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:54 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F2 FLOOR PLAN AE102 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F2 FLOOR PLAN DNUP DN UP AE202 D1 AE201 D1 AE201 A1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 22'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"72'-0"28'-0"24'-0"24'-0"24'-0"A2 AE301 A2 AE301 AE202A1 D1 AE301 D1 AE301 2-HOUR RATED GLASS REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS B B C C 2-HOUR RATED GLASS ELEVATOR #1 SERVICE ELEVATOR ELEVATOR #2 ELEVATOR #3 CUSTODIAL ELEVATOR VESTIBULE PLUMBING AND GAS STORAGE RESTROOM RESTROOM MECHANICAL SHAFT STORAGEMECHANICAL SHAFT STAIR A STAIR B SHAFT SHAFT SHAFTSHAFT STORAGE SERVICE ELEVATOR ELECTRICAL ROOM PLUMBING RISER ELECTRICAL RISER MECH SHAFTMECH SHAFT ELEVATOR VESTIBULE HAZARDOUS MATERIAL STORAGE SAMPLE RECIEVING LOCKERS / COATS LOCKERS / COATS STORAGEAUTOCLAVE & GLASS WASH ELECTRICAL ROOM PLUMBING RISER ELECTRICAL RISER MECH SHAFTMECH SHAFT IDF LOCKERS / COATS LOCKERS / COATS SAMPLE RECEIVING PHONE PHONEHUDDLE FOCUS FOCUS HUDDLE HUDDLE RESPITE RESTROOM MOTHER'S BREAK / PANTRY TOUCHDOWNS FOCUSFOCUSHUDDLE CONTROL AREA 1 CONTROL AREA 2 SERVICE CORRIDOR FLOOR PLAN GENERAL NOTES 1. RESTROOMS: NEW COUNTERS, FIXTURES, TOILET PARTITIONS, FINISHES AND ACCESSORIES. 2. STAIRWELLS: NEW PAINT, FINISHES, LIGHTING & GUARDRAILS (CODE COMPLIANT) 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:55 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F3 FLOOR PLAN AE103 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F3 FLOOR PLAN DNUP DN UP AE202 D1 AE201 D1 AE201 A1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 22'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"72'-0"28'-0"24'-0"24'-0"24'-0"A2 AE301 A2 AE301 AE202A1 D1 AE301 D1 AE301 2-HOUR RATED GLASS MECHANICAL SHAFT ABOVE REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS B B C C 2-HOUR RATED GLASS ELEVATOR #1 SERVICE ELEVATOR ELEVATOR #2 ELEVATOR #3 CUSTODIAL ELEVATOR VESTIBULE PLUMBING AND GAS STORAGE RESTROOM RESTROOM MECHANICAL SHAFT STORAGEMECHANICAL SHAFT STAIR A STAIR B SHAFT SHAFT SHAFTSHAFT CONTROL AREA 1 CONTROL AREA 2 MECH SHAFT LOCKERS / COATS AUTOCLAVE & GLASS WASH ELECTRICAL ROOM IDF SAMPLE RECEIVING STORAGE LOCKERS / COATS MECH SHAFT ELECTRICAL RISER PLUMBING RISER MECH SHAFT LOCKERS / COATS SERVICE ELEVATOR ELEVATOR VESTIBULE PLUMBING RISER ELECTRICAL RISER ELECTRICAL ROOM HAZARDOUS MATERIAL STORAGE SAMPLE RECIEVING STORAGE LOCKERS / COATS MECH SHAFT FOCUS FOCUSHUDDLE TOUCHDOWNS FOCUSFOCUSHUDDLE HUDDLE HUDDLE RESPITE RESTROOM MOTHER'S TOUCHDOWNSSERVICE CORRIDOR BREAK / PANTRY FLOOR PLAN GENERAL NOTES 1. RESTROOMS: NEW COUNTERS, FIXTURES, TOILET PARTITIONS, FINISHES AND ACCESSORIES. 2. STAIRWELLS: NEW PAINT, FINISHES, LIGHTING & GUARDRAILS (CODE COMPLIANT) 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:57 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F4 FLOOR PLAN AE104 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F4 FLOOR PLAN DN DN UP AE202 D1 AE201 D1 AE201 A1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 A2 AE301 A2 AE301 AE202A1 CUSTODIAL ELEVATOR VESTIBULE PLUMBING AND GAS STORAGE RESTROOM RESTROOM MECHANICAL SHAFT STORAGE STAIR A STAIR B SHAFT SHAFT SHAFT FOCUS PHONE PHONE HUDDLE FOCUS CLINICAL DEVELOPMENT LAB - CONTROL AREA 2 D1 AE301 D1 AE301 22'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"72'-0"28'-0"24'-0"24'-0"24'-0"SHAFT MECHANICAL SHAFT SERVER ROOM MECHANICAL SHAFT UP 2-HOUR RATED GLASS FOLDING GLASS WALL/ DOOR SYSTEM REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS EXISTING SHIP LADDER TO ROOF MLSP TRAINING - CONTROL AREA 1 B B C C BUILDING MANAGEMENT MECH SHAFT TECH SUPPORT STORAGEELECTRICAL ROOM ELEVATOR VESTIBULE PLUMBING RISER ELECTRICAL RISER 2-HOUR RATED GLASS OFFICE MECH SHAFT HUDDLE FOCUS SERVICE ELEVATOR TECH STORAGE REPLACE ELEVATOR VESTIBULE DOORS WITH NEW GLASS SMOKE CONTROL DOORS WITH KEY CARD ACCESS MECH SHAFT LOCKERS / COATS ELECTRICAL ROOM IDF SAMPLE RECEIVING STORAGE LOCKERS / COATS MECH SHAFT ELECTRICAL RISER PLUMBING RISER RESPITE HUDDLE HUDDLE RESTROOM SERVICE CORRIDOR FLOOR PLAN GENERAL NOTES 1. RESTROOMS: NEW COUNTERS, FIXTURES, TOILET PARTITIONS, FINISHES AND ACCESSORIES. 2. STAIRWELLS: NEW PAINT, FINISHES, LIGHTING & GUARDRAILS (CODE COMPLIANT) 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:55:58 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN F5 FLOOR PLAN AE105 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 F5 FLOOR PLAN DN AE202 D1 AE201 D1 AE201 A1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A A D D E E F F G G H H 1 1 A2 AE301 A2 AE301 AE202A1 HOISTWAY RELIEF VENT SHAFTS MECHANCIAL PENTHOUSE D1 AE301 D1 AE301 22'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"32'-0"72'-0"28'-0"24'-0"24'-0"24'-0"STAIR B MECHANICAL YARD MECHANICAL SCREEN NEW MECHANICAL PENTHOUSE. EXTERIOR WALL FINISH TO BE METAL BOX-BEAM. B B C C 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 5:05:19 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN R1 ROOF PLAN AE106 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"A1 R1 ROOF PLAN F1 0' - 0" F2 19' - 6" F3 33' - 6" F4 47' - 6" F5 61' - 6" 23456789 1 T.O. PARAPET 77' - 8" EXTENTS OF EXISTING EQUIPMENT SCREEN TO BE REMOVED PENTHOUSE ROOF 86' - 9 1/2" NEW ELEVATOR HOISTWAY RELIEF VENT METAL BOX-RIB EQUIPMENT SCREEN AND STRUCTURAL SUPPORTS NEW CMU GENERATOR SCREEN WALL F1 0' - 0" F2 19' - 6" F3 33' - 6" F4 47' - 6" F5 61' - 6" A D E F G H T.O. PARAPET 77' - 8" METAL BOX-RIB EQUIPMENT SCREEN AND STRUCTURAL SUPPORTSEXTENTS OF EXISTING EQUIPMENT SCREEN TO BE REMOVED EXISTING EQUIPMENT SCREEN PENTHOUSE ROOF 86' - 9 1/2" F1.5 10' - 3 7/8" EXISTING FENCE B C NEW CMU GENERATOR SCREEN WALL 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 5:29:39 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN EXTERIOR ELEVATIONS AE201 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"D1 NORTH ELEVATION 1/8" = 1'-0"A1 WEST ELEVATION F1 0' - 0" F2 19' - 6" F3 33' - 6" F4 47' - 6" F5 61' - 6" 2 3 4 5 6 7 8 91 T.O. PARAPET 77' - 8" EXISTING EQUIPMENT SCREEN PENTHOUSE ROOF 86' - 9 1/2" F1.5 10' - 3 7/8" METAL BOX-RIB EQUIPMENT SCREEN AND STRUCTURAL SUPPORTS F1 0' - 0" F2 19' - 6" F3 33' - 6" F4 47' - 6" F5 61' - 6" ADEFGH T.O. PARAPET 77' - 8" PENTHOUSE ROOF 86' - 9 1/2" F1.5 10' - 3 7/8" METAL BOX-RIB EQUIPMENT SCREEN AND STRUCTURAL SUPPORTS BC 223 YALE AVENUE NORTH SEATTLE, WASHINGTON 98109 PHONE 206 223 5555 www.nbbj.com PROJECT NUMBER PROJECT ARCHITECT SHEET NAME SHEET NUMBER PROJECT MANAGER: STRUCTURAL ENGINEER: MEP: REVISIONS MARK DATE DESCRIPTIONB 1 2 A C D E 3 4 5 6 1 2 3 4 5 6 F B A C D E F CBRE 1420 5TH AVE, SUITE 1700 SEATTLE, WA 98101 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 WSP USA 1001 FOURTH AVE., SUITE 3100 SEATTLE, WA 98154 LAB CONSULTING MANAGER: WESTLAKE CONSULTING GROUP 2825 EASTLAKE AVE. E, SUITE 350 SEATTLE WA 98102 LAB PLANNING: WSP USA 3340 PEACHTREE ROAD NE, SUITE 2400 ATLANTA, GA. 30326 3/15/2023 4:56:05 PMAutodesk Docs://102987.00 - UW DLMP R22/ARCH_UW DLMP_TI.rvt102987.00 S.LAZEN EXTERIOR ELEVATIONS AE202 UW DLMP CENTRAL LABS TI CONDITIONAL USE PERMIT MARCH 16, 2023 1/8" = 1'-0"D1 SOUTH ELEVATION 1/8" = 1'-0"A1 EAST ELEVATION