HomeMy WebLinkAboutS-397503O
M
Z
O
Z
LU
x
LU
w
LU
3:
LU
U)
Q
a
LU
O
♦w
V
w
LL
V
W4
CL
/
w
N
C-D
z
w
w
z
cD
z
w
/
in
z
0
N
z
w
X
LLI
w
w
W
U)
Y
a
LLI
o
Q:fa
CDtDg
Q:fooW
C�
C.9
O
�rnv�
L;j L,..i L,..i M
LLI
WHOI
J Q OJ N
SE 1/4, SEC. 03, TWP. 23N, RGE. 05E., W.M.
\\ \ EXISTING FIRE H�DRANT
I /
.000
l 1 I
/
475
0
EX. 8" DI WATER MAIN / — 1 � —f ` J 465/
\� to /
CONSTRUCTION / III IIII REMOVE CLEANOUT, EXTEND
ENTRANCE SANITARY SEWER PIPE WITH
\\moo \1 \l \\ \\\ \�\—�/ I I \� / I III 1 IIII LIKE MATERIAL AND SLOPE
EXISTING FIRE HYDRANT
Iry v\ vv \l b
\ 1 I I III EX. DRAIN i
470I it 1 1 I III 11\ FIELD TO BE
\ V A V I I 1 1 1 1 I III I ABANDONED
CC
f�
9 o III I III \ ABANDON AND CAP I
\ \ -H \ I \ --------- RENTON=/SSAQUAH RD I I I 1 I \
\ N \ \ _; 1 I I III I EX. SEPTIC PIPE
\ 1 001 I� \� �� — _ 11� I 3 4 111 1 1 \`
—��J-� I 3 4 1 0 — \\
C \ Os EX. SEPTIC PUMP \ \
3 O TO BE ABANDONED \
EX. DRAIN I II \ \\ /*/ II 1 \-1 I 1 2 3 4 \I V\
FIELD TO BE i >I \ \
ABANDONED I I \\ \ Il I \ III II b
ASPHALT
DRIVE
4 3
EX. SINGLE I — — I\4�s I I SILT FENCE,
I ) \ FAMILY HOME
I SEE SHEET C3.013 4 EXISTING SEPTIC
(TYP) 4 3 TANKTO BEREMOVED I
EX. SEPTIC PUMP TANK
TO BE ABANDONED
ABANDOrI AND CAP—
\ I \ EX. SEPTIC PIPE
`475� 1 H-
`� 1 I
CLEARING LIMITS
\6S �,
\ EX. DRAIN F LD TO BE 465 / \\
ABANDONED
�
y
DEMOLITION NOTES
WAC246-272A-0300
PERSONS PERMANENTLY ABANDONING A SEPTIC TANK, SEEPAGE
PIT, CESSPOOL, OR OTHER SEWAGE CONTAINER SHALL:
(1) HAVE THE SEPTAGE REMOVED BY AN APPROVED PUMPER;
(2) REMOVE OR DESTROY THE LID; AND
(3) FILL THE VOID WITH SOIL OR GRAVEL.
SEPTIC MECHANICAL
AND ELECTRICAL
DECOMISSIONING PLAN
O1 REMOVE ALL EXISTING MECHANICAL AND MCC EQUIPMENT.
O2 DISCONNECT AND REMOVE ALL ELECTRICAL COMPONENTS AND
SERVICES.
O3 REMOVE SEPTAGE AND CLEAN WET WELLS.
O4 FILL VOIDS WITH SAND OR GRAVEL OR REMOVE STRUCTURE IF
NECESSARY.
LEGEND
—o—o—o—o—o—o—o— CLEARING LIMITS
* * * SILT FENCE 2
C3.01
W EXISTING WATER
SEPTIC TANK
NOTE:
MLM31-I CCJ VVILL DC r muviULU IIV I mr- rICLU I V r Mr-VCIV I J I UMM
AND SURFACE RUNOFF FROM GOING OUTSIDE SITE PROPERTY
LINES DURING CONSTRUCTION.
O
TM
qe
qq
O
O
r
V
LO
L!i
\ 1 \
41 � I — Cl)
I
BANDON AND CAP I I �
SEPTIC PIPE I I I EX. TRAILER 1 �
1 s \ \ I I I I I HOMES (TYP) \ / c ,/ ~ ��_ Z
0
0 \�Jo ro Z
s
'sue — �— \ \ \\ I > \ - - - - - - - - I (0 �\
`\ �� v \ �\ I 3 4 GRAVEL DRIVE _,. / (� N W
--------------- ABANDON EX. ti F—
`—o �'k 'k SEPTIC PIPE \ ,�� ��/ RECORD
661'f �? —' LU
1 t I �� DRAWINGS oc
0 20 40 80 LU
\ 1 `4. Scale In Feet S-397503
U � LU
rn P Q \ /
; ) 1 � �Q,o\ ( s� _ ✓t IN COMPLIANCE WITH CITY OF RENTON STANDARDS U)
01
�4 1pyhom
CALL BEFORE LU
YOU DjG 811 ftw-ft.
oAn Engineering Services Company UNDERGROUND SERVICE (USA)
Q tij SURVEYED. SCALE: DATE: O
VERTICAL: NAVD 1988 •
11255 Kirkland Way, Suite 300 AS NOTED HORIZONTAL' NAD 1983/1991 FIR GROVE PARK SEWER EXTENSION 2017/ 10/09 W
DESIGNED: CITY 0 F EXISTING CONDITIONS, TESC &
f Kirkland, WA 98033 PRIFlELDBOOK: l♦'wJ
4340 p. 425.827.20141 f. 425.827.5043 DRAWN: RENTON PAGE: �/
SIONAL . ' ' ' ' ' ' ' ' ' ' . ' " ONE INCH DEMOLITION PLAN DATUM DRAWING NO: w
If
Civil Structural Planning Survey 1 REVISED PER CITY COMMENTS DATED 10/4/2017 BM 10/5/17 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. 5325 NE SUNSET BLVD, RENTON, WA 98049 C2.00 —
D/ 5117 F NOT ONE INCH
paceengrs.com SCALE CALE ACCORDINGLY
NO. REVISION BY DATE APPR APPROVED: FIR GROVE PARK SEWER EXTENSION SHEET: 3 OF: 7 LL
PACE JOB NUMBER: 17430