Loading...
HomeMy WebLinkAboutR-423022PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP", STD. SPEC. 9-05.20 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15 " CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND SEE NOTE 1 REMAIN VISIBLE UPON COMPLETION. ALTERNATIVE PRECAST BASE SECTION UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) A09" STD. PLAN - 200.00 cj�PUBLIC WORKS APPR ED: DEPARTMENT CATCH BASIN TYPE 1 GAZ 9/28/2018 rueuc woks aemminrawr DATE 24" 1 O 2 1/2" DIA. HOLE O ooaoaoo TOP m 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION NOS:6 EE A" #3 BAR EACH CORNER #3 BAR EACH SIDE ..AR EACH WAY Y PRECAST BASE SECTION #3 BAR HOOP #3 BAR EACH CORNER 18" MIN. I I 11T BOLT -DOWN SLOT, W4" SEE DETAIL AND NOTE 1 1 1/4" �I 5/8" T I I BOLT -DOWN SLOT DETAIL L _ _ _ SEE NOTE 1 3' R26", SEE NOTE 2 1 112' ISOMETRIC I� 4 3/4' 1 1 r 1 1l2" SECTION B 1 5/8" MAX. R39", SEE NOTE 2 5„ NOTES: 3 1/2" 314" 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. y8 PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN 4" HEAD CAP SCREW BY BEING TAPPED, OR OTHER If _ 3/4" DIA. HOLE APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. L 1/2" DIA. HANDLE 1 1/2" 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. SECTION C 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS) a STD. PLAN - 204.10 • PUBLIC WORKS RECTANGULAR SOLID METAL COVER 9/28/2018DEPARTMENT[G;Z vonn<worksnami„isrzasor DATE :45 Al :4S AN CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) - MORTAR, (TYP.), SEE NOTE 5 4" MIN. 28" MAX. 16" MAX. FLAT SLAB TOP 48", 54", 60", 72",4", 8 96", 120" OR 144" SEE NOTE 6, TYP. 15' MAX. FOR MAINTENANCE STEPS OR LADDER `- �o T "MIN. "O" RING 24" 2 5" MAX REINFORCING STEEL, (TYP.) MIN. 12" MAX. 12" + GRAVEL BACKFILL FOR PIPE ZONE 12^ BEDDING PER WSDOT STD. _ SPECIFICATION SECTION 9-03.12(3) 6" 6" SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE OP SLED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4, KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. • PUBLIC WORKS DEPARTMENT CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4" 6" 36" 8" 54" 4.5" 8" 42" 8" 60" 5" 8" 48" 8" 72" 6" 8" 60" 12" 84" 8" 12" 72" 12" 96" 8" 12" 84" 12" 120" 10" 12" 96" 12" 1"" 12" 12" 108' 1 12" PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER CONCRETE ALL METAL CPSSP SOLID WALL PVC, PROFILE WALL PVC, 48" 24" 30" 24" 30" 30" 1.DIAMETER 30" 36" 30" 36" 36" 60" 36" 42" 36" 42" 42" 72" 42" 54" 42" 48" 48" 84" 54" 60" 54" 48" 48" 96" 60" 72" 60" 48" 48" 120" 66" 84" 60" 48" 48" 144" 78'1 96" 1 60" 48" 48" 'CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 3 STD. SPEC. 9-05.12(1) 'STD. SPEC. 9-05.12(2) CATCH BASIN TYPE 2 a FLOW o 0 0T TI-T 7 0 OUTFACE TO STREAM DUMP NO POLLUTANTS UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 201.00 [PIOV�D GAZ 9/28/2018 I r„euc woes nemimsaamr DATE I 1 1 BOLT -DOWN SLOT, I 112" SEE DETAIL AND _NOTE 1 I11iI I t/4/4" I I � I I I I I I BOLT -DOWN SLOT DETAIL L _ _ _ SEE NOTE 1 _ _ _ J TOP m /\ VA' RFCFSSFO I FTTFRINr W ISOMETRIC i� 3" 5' 5" 5" 20" 5" 5" 24" 7 OR 8 EQUAL SPACES 5" 1DIRECTION FLOW I 3' 1 5/8" MAX. -T ��� SECTION A SECTION B NOTES: i. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 518"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) RD STD. PLAN - 204.20 a PUBLIC UBLIC WORKS RECTANGULAR VANED GRATE GAZ 9/28/2018 1 Vubucworks name"�nnw, DATE :45 AI :45 SEE NOTE 4 CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION ADJUSTMENT SECTION I I I I I I I I NOTES: 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED, 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Yz BOND. 5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR. 6. MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3. 7. PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. 2'. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 202.00 •tea PUBLIC WORKS vao III DEPARTMENT CATCH BASIN INSTALLATION GAZ 9/28/2018 1 9 vobrr worws namimsvxor DATE -24- 4 EQUAL SPACES 4 EQUAL SPACES 1 5/8" MAX. J I I 1 1/2" BOLT -DOWN SLOT, SEE DETAIL AND 3/4" NOTE 1 1 1I/4" I � I I r1 I I I BOLT -DOWN SLOT DETAIL L _ _ _ SEE NOTE 1 SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"A 1 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. USE ONLY IN SAGS ON VERTICAL CURVES. 4. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS) STD. PLAN - 204.30 PUBLIC WORKS RECTANGULAR BI-DIRECTIONAL PR D .•.� DEPARTMENT VANED GRATE GAZ 9/2s/2o18 s Aem, DATE 1 CITY COMMENTS SES 10/12/2 SHM SURVEYED: RDW 2 REVISE WALL SES 3/7/23 SHIM DESIGNED: 3 CITY COMMENTS SES 1 /25/23 SHIMSHM 4 CITY COMMENTS SES 6 5 23 SHM °RA'"" SES CHECKED: SHY NO. REVISION BY DATE APPR APPROVED: SHM :4S A :4S AN RECESSED ALLEN HEAD CAP SCREW 5/8"-11 NC x2" GRATE FRAME SECTION BOLT -DOWN DETAIL SEE NOTE 2 TOP 24 1!4" I SECTION A SEE DETAIL ISOMETRIC VIEW / 7l8" 1/8" ' 11/4^ , N. THIS FRAME IS DESIGNED TO ACCOMMODATE 20"x OTES: 1 4 1/2" I 1 SEE STANDARD PLANS 204. 0 204.20, 2D4 30, AND 204.40.�TES OR COVERS, 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, OTHERWISE SPECIFIED.\ �I TWO HOLES IN THE FRAME THATLESS ARE VERTICALLY ALIGNED WITHODE THIE GRATE OR COVER SLOTS. 1 5/8" / THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2"ALLEN HEAD CAP SCREW BY 3/4" BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF \ BOLT -DOWN HOLES VARIES BY MANUFACTURER. \ 2 1/2" 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL \ DETAIL REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 204.00 PUBLIC WORKS ArMNARECTANGULAR FRAME GAZ 9/28/2018 � DEPARTMENT AZ YP.b oM1S A­msnamr DATE 1/2" LETTERING - BOLT HOLES-3 PLACES EQUALLY SPACED 120" APART ON 23 1/16" DIA. B.C. RENTO 0 DRAIN (1) 1- DIA. PICKHOLE e� nu view 11/4"LETTERING 25" DIA. 3/4" 8 3/4" III_ (TYP.) COVER SECTION VIEW 26 1/2" DIA. 25 1/4" DIA. 1/4" DIA. NEOPRENE GASKET .-T L\� 3 3 2 s/E" ,0 DIA. CL OPEN 27 5/16" DIA. 34 1/8" DIA. FRAME SECTION VIEW COVER BOTTOM VIEW (3) BLT SOC. (ALLEN HEAD) 50-11 x 1.5 SS RUBBER WASHER EON BOLTING DETAIL [ 1 1/16" R1/8" GASKET GROOVE DETAIL NOTES: 1. ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL. STD. PLAN - 204.50 • PUBLIC WORKS STORM ROUND FRAME AND COVER '11� (PUBLIC) DEPARTMENT artin Pastucha$/13/2020 VAMVV "7�F8B449D... DATE PROJECT NO. 20134 % SIDEKO .pF WAS y11000 �9 CIVIL ENGINEERING Z: LANDSCAPE ARCHITECTURE `off,•. ,�, 41846 O �� PLANNING onn��s TONAL �NG\��� DESIGN SURVEYING -5-23 72100 NE 795th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 SCALE: VERTICAL. HORIZONTAL NAD 1983/1991 A10atk CITY Y OF r3 RENTON ONE INCH DATU M Planning/Building/Public Works Dept. AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY :45 AP 1 8:48 R-423022 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Wanders 06/07/2023 STORM DETAILS DATE: MARCH 2O22 FIELDBOOK: PAGE: DRAWING NO: C4.35 SHEET: 22 OF: 40