HomeMy WebLinkAboutS-423006r--i-r---------- ��.� EX. SEWER MAIN l PROPERTY LINE FV�SIEWER S NEEDED) I I I I.—S-O" MIN I II b I ER STUB I 1 ;� "!d+y FUTURE 4' SIDE SEWER OC----------3 I I I I- 2"x 4" STUD MARKING POST PAINTED 6' CAP JJJ WHITE WITH THE WORD "SEWER" STENCILED E X 6" TEE i i i I IN 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK ? WRAPPED AROUND THE STUD AND I i I i i EXTENDED TO THE TOP OF THE STUD COUPLING TYP ' ' ' ' rr� I; 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER 0 (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR APPROVED EQUAL, SPECIFY "SEWER' ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD I CONCRETE PAD TO BE 8" IN DEPTH __ 1 1 `---� t BEND AS �1 8" REQUIRED EXISTING SANITARY SEWER MAIN ---2.0R MIN SLOPE \ !\\ `FUTURE 4" SIDE SEWER SEWER STUB 6"X6"X6" WYE LFUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC 'TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC do C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE- USING "STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES. 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHAL L HAVE A MINIMUM 2 9. SLOPE UNLESS APPROVEDY THE PUBLIC B E UBL C WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB STD. PLAN - 406.1 PUBLIC WORKS INSTALLATION APP „•aey: R DEPARTMENT Martin PastUCftW26/2oz (SEWER MAIN TO PROPERTY LINE) 88618+ED98B449D DATE BOLTHOLES - 3 PLCS EQUALLY SPACED 120' APART ON 23 1/16' (586mm) DIA BC (SEE DETAIL) RENTON O SEWER ti COVER & FRAME PLAN VIEW 25' DIA C635mm] 1' 3/4' 125mm] C19mm] 8 3/4' 2 112' - 1222mm] 164mm] TYP COVER SECTION VIEW COVER BOTTOM VIEW <3) HLT SOC (ALLEN HEAD) 5/8'-11 X 15 SS RUBBER WASHER BOLTING DETAIL 26 1/2' DIA C673mm] 25 1/4' DIA 1641mm] 1 1/16' 1 1/16' 1/4' (6mm) DIA C27mm] [6mm] 127mm1 NEOPRENE GASKET 1 6' 1152mm] [3mml Lt —1 ve• 5/8' 23 3/8' DIA CL OPEN [R3mm] [16mm] [594mm] GASKET GROOVE DETAIL 27 5/16' DIA C694mml 34 1/8' DIA C867mm] NOTES FRAME SECTION VIEW 1 ALL FRAME AND COVER ASSEMBLIES SHALL HAVE A LOCKING LID PER EAST JORDAN IRON WORKS INC PRODUCT No 00371572 OR EQUAL. 2 USE FRAME AND COVER FOR SANITARY (SPECIFY "SEWER") STD. PLAN - 401.1 .. PUBLIC WORKS SEWER MANHOLE FRAME AND COVER 26/202 '+it DEPARTMENT (CITY -OWNED) Martin Pastucna B449D.. DATE 1 12 : WASTEWATER UTILITY STANDARD NOTES 1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION 2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS 3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS, INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION 4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY 5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. 6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES 7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19). 8 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034, SDR 35, C900/C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY 9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC) UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412 10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE BACKFLLLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY 11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND AT PE IF S C IC ION OF THE CITY AND THE LATEST S EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS & SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN 405 12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE COMPLETION OF CONSTRUCTION I N ACCORDANCE WITH THE CURRENT U T SURFACE WATER DESIGN MANUAL 13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR S, PLAN - 413 ♦ PUBLIC WORKS WASTEWATER UTILITY APPROVED' V'1� DEPARTMENT STANDARD NOTES Martin PastuchaO/26/2 _ DATE �—W (SEE NOTE 7) LIMITS OF PIPE ZONE i 6" BEDDING MATERIAL FOR O.D. SANITARY SEWER PIPE of (SEE NOTE 5) PIPE FOUNDATION LEVEL 6" BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS 5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3) OF THE STANDARD SPECIFICATIONS 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED 7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 PUBLIC WORKS PIPE BEDDING APP URDEPARTMENT FOR SANITARY SEWERS Martin PastuCft&/26/202 �449D DATE NOT TO SCALE MANHOLE FRAME AND COVER SEE STD PLAN 401 ADJUSTMENT RINGS AND MORTAR JOINTS SEE NOTE 3 FIRST STEP SHALL BE A MAXIMUM OF 18 BELOW THE COVER CONE (ECCENTRIC) STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED RUBBER GASKETED JOINTS SEE NOTE 5 IF REQUIRED, LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX PIPE SIZE - 'E' SHELF AND CHANNEL SHALL BE 3000 PSI CONCRETE PRECAST BASE SECTION OR CAST IN SHELF COMPACTED SUBGRADE WITH 6" CRUSHED ROCK OR ADDITIONAL MATERIAL SUITABLE TO SUPPORT STRUCTURE `A' 'B' 'C' 'D' I 'E' 48" MH 4811 6" MIN. 5"MIN 24" MIN. 21" I D 54" MH 54" 8" MIN 5 5" MIN 24" MIN 24" 1 D 60" MH 60" 1 8" MIN 1 6" MIN 42" MIN 1 30" 1 D NOTES. 1 STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED 2 MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE IN CONFORMANCE WITH ASTM C-478. 3 ADJUSTMENT OF THE CASTING TO GRADE SHALL BE PER STD PLAN 106 THE USE OF SHIMS IS PROHIBITED. 4 SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, FACTORY -COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING, WASSER MC-SHIELDCOAT 100 OR APPROVED EQUAL, COLOR OF COATING SHALL BE WHITE 5 RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443 6 CHANNEL WIDTH AND HEIGHT SHALL EQUAL THE INSIDE DIAMETER OF THE LARGEST PI PE 7 CONNECTIONS TO MANHOLE SHALL BE MADE USING KOR-N-SEAL BOOTS OR APPROVED EQUAL 8 IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE AN AT -GRADE, MINIMUM 2'-WIDE CONCRETE RING POURED AROUND THE COVER IN PAVED AREAS, COVER MUST SLOPE TO MATCH PAVING. 9 MANHOLES OVER 20' DEEP SHALL BE A MINIMUM OF 60" IN DIAMETER STD. PLAN - 400.1 UR�9na y ♦ . PUBLIC WORKS STANDARD SANITARY MANHOLE 26/202 �l� DEPARTMENT Martin Pastuct�ci bD. DATE EXISITNG PIPE Iw A CAST -IN -PLACE CONCRETE BASE UNDER PRE -CAST SADDLE MANHOLE SECTION REMOVE U EXISTING F SHELF AND BE 3000 PS • 4 4 �,• AI � • r d D - I NEW PIPE rt .. IN..�• . ' .•r x A I ' ' - s ..r. � I .. .R•!� .1.. •:.•,y it •`� • .t ..�' •7 1' -A• .•�• •. .. I'! • f•. + !•MIN. ,r? TOP VIEW OPEN PIPE CHANNEL DRECAST SADDLE MANHOLE SECTION I)-4"(W) x 8"(H) x 16"(L) )LID CONCRETE BLOCKS 4INIMUM) $ REBAR ------ DLE TI ON 'HANNEL FLUSH WITH PIPE AND SHELF AT PER FOOT OR 2% 'E -IN-PLACE CONCRETE POURED 4" ABOVE THE CONCRETE BLOCKS IUM 12" THICK) I)-4-(W) X 8"(H) X 16"(L )LID CONCRETE BLOCKS CNIMUM) �- CAST -IN -PLACE CONCRETE '—COMPACTED SUBGRADE WITH 6" BASE POURED 4" UNDER CRUSHED ROCK OR ADDITIONAL SEWER MAIN AT A MINIMUM OF FOUNDATION ROCK TO SUPPORT 10" THICK STRUCTURE NOTES. 1. EXISTING PIPE SHALL BE SUPPORTED AT ALL TIMES 2 NO WEIGHT OF THE PRECAST MANHOLE UNIT SHALL BEAR ON THE EXISTING PIPE 3 CAST -IN -PLACE BASE SHALL BE 3000 PSI COMMERCIAL CONCRETE 4 PRECAST MANHOLE SECTIONS SHALL BE INSTALLED IN ACCORDANCE WITH THE STANDARD PLAN FOR THE SPECIFIED MANHOLE SIZE AND TYPE 5 PRECAST MANHOLE SECTIONS SHALL HAVE THE INTERIOR SURFACES FACTORY -COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING, WASSER MC-SHIELDCOAT 100 OR APPROVED EQUAL, COLOR SHALL BE WHITE 6 THE PRECAST MANHOLE SECTION SHALL SIT ON (4)-4"(W) X 8'(H) X 16"(L) SOLID CONCRETE BLOCKS PLACED ON COMPACTED SUB -GRADE 7 THE UPPER HALF OF THE EXISTING PIPE (PVC PIPE ONLY) SHALL BE REMOVED WHILE THE BOTTOM SHALL REMAIN AS THE CHANNEL OF THE NEW MANHOLE. 8 THE CAST -IN -PLACE MANHOLE SHALL NOT BE INSTALLED OVER A BELL SECTION OR JOINT OF THE SEWER MAIN THE MINIMUM DISTANCE FROM THE OUTSIDE WALL OF THE MANHOLE AND A BELL SECTION OR JOINT SHALL BE 2' PP ST�y PLAN - 400.6 .VI PUBLIC WORKS SADDLE MANHOLE A -i < DEPARTMENT WITH CAST -IN -PLACE BASE Martin Pastu6/202 F j� B449D DATE 1 CITY COMMENTS SES O/12/2 SHM SURVEYED: RDW 2 REVISE WALL SES 3/7/23 SHM DESIGNED: SHM 3 CITY COMMENTS SES 1 /25/23 SHM 4 CITY COMMENTS SES 6 5 23 SHM DRAWN: SES CHECKED: SHM N0. REVISION BY DATE APPR APPROVED: SHM BOLTHOLES - 3 PLCS EQUALLY SPACED 120° APART ON 23 1/16° (586mm) DIA B.C. (SEE DETAIL) :RENTON SEWER a COVER & FRAME PLAN VIEW 25' DIA. C635mm7 1" 3/4° 25mm] [19mm] 8 3/4" 2 1/2' 1222mm] C64mm] TYP COVER SECTION VIEW 26 112' DIA C673mm] 25 1/4' DIA 1641mm] 1 1/16" 1/4' (6mm) DIA C27mm] NEOPRENE GASKET 1 6' T C151 mm] 5/8' J 23 3/8' DIA CL OPEN C16mm] C594mm] 27 5/16' DIA C694mm] 34 1/8" DIA_ COVER BOTTOM VIEW BLT SOC.(ALLEN HEAD) 5/8"-11 X 1.5 SS RUBBER WASHER BOLTING DETAIL 1/4" C6mm7 1 1/16" C27mm7 C3mm] 1/8, CR3mm] GASKET GROOVE DETAIL [867mm] NOTES: FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER' ), OR WATER (SPECIFY "WATER"). STD. PLAN - 401 UR♦0 PUBLIC WORKS PPR D: '1` DEPARTMENT MANHOLE FRAME AND COVER GAZ 9/11/2019 1 a.—b­­i n DATE TEE OF APPROPRIATE SIZE USE ROMAC COUPLING OR APPROVED EQUAL WHEN 60" MIN CONNECTING TO AN EXISTING FOR NEW SEWER MAIN MANHOLES �r SEE NOTE 7 4• "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL 90' BEND EMBEDDED IN CONCRETE �r 4 ••' 1 112 THE DIAMETER OF ' • THE DOWNSTREAM PIPE NOTES 1. SANITARY SEWER DROPS ARE ONLY TO BE USED UPON APPROVAL BY THE WASTEWATER UTILITY SECTION 2 DROP PIPES AND FITTINGS SHALL BE PVC SDR 35 WHEN CONNECTING TO ALL EXISTING SEWER MAIN MATERIALS EXCEPT DUCTILE IRON. USE AWWA C900 PIPE AND AWWA C907 FITTING WHEN CONNECTING TO DUCTILE IRON SEWER MAINS 3 MINIMUM SIZE MANHOLE FOR INSIDE DROP CONNECTION SHALL BE 60" DIAMETER 4 CONNECTIONS TO MANHOLE SHALL BE CORE DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL 5 USE ROMAC COUPLING OR APPROVED EQUAL WHEN CONNECTING TO AN EXISTING MAIN 6 WITHIN A 60" DIAMETER MANHOLE, THE MAXIMUM ALLOWABLE DIAMETER OF THE INSIDE DROP PIPING IS 12" INSIDE DROPS EXCEEDING 12" IN DIAMETER OR MULTIPLE DROPS SHALL BE REVIEWED BY THE WASTEWATER UTILITY AND MAY REQUIRE A LARGER DIAMETER MANHOLE. 7 "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL SHALL BE INSTALLED WITHIN 6" OF BOTH BELL AND SPIGOT ENDS OF EACH DROP PIPE IF DROP PIPE LENGTH EXCEEDS 5 FEET THEN CENTER STRAPS SHALL BE INSTALLED WITH A MAXIMUM SPACING OF 4 FEET ON CENTER BRACKETS SHALL BE ATTACHED UTILIZING STAINLESS STEEL EXPANSION BOLTS, MIN 2 EACH AT CONNECTION POINTS 8 MANHOLE CONE SECTION AND ACCESS LADDER MAY NEED TO BE RELOCATED TO ALLOW DROP PUBLIC WORKS INSIDE DROP CONNECTION APsURIT PLAN-402.2 DEPARTMENT Martin Pastuchc&/26/z 1 FOR SANITARY MANHOLE weo<wn..4,,,I"n,.m,wu DATE S-423006 SCALE: HORIZONTAL NAD 1983/1991 CITY OF RENTON ONE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY RECESSED Not to Scale LIFT POCKET CU�SEWER FRAME 3/4" LETTERING "SEWER" DIAMETER40 (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1 5 STAINLESS C� STEEL REF PART #00981177 1-3/16" T SEE NOTE 3 to-1/z" 5/8" 1/4" 12-1/2"� 1 1-1/8" 2-1/4" f 2 1 3/4--­'I 1 1 11 /8,• 8„ 11/1 " 12-4" CAST IRON RING AND COVER BOLT DETAIL 45' (1/8) BEND �P 40 h�X J� �O G\�P — 45- (1/8) BEND SAND OR EXPANDABLF FOAM PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES, 1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER 3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106 STD. PLAN - 403.1 PUBLIC WORKS 8" OR 6" CLEANOUT �t9^e y DEPARTMENT FOR SANITARY SEWER MAIN Martin PastuCiW26/2020 DATE SIDEKO 'pF • WAYy9 hP �. :Cl) O• T -o� ,•,PF 41846 � o�FSS/cNAL PROJECT NO. 20134 G-5-23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING NJanders 06/07/2023 WASTEWATER UTILITY jstowell 06/08/2023 MARCH 2O22 FIELDBOOK: PAGE SEWER DETAILS DRAWING N0: C5.31 SHEET: 29 OF: 40