Loading...
HomeMy WebLinkAbout7945.04 E 2023 0619Earth Solutions NWLLC 15365 NE 90th Street, Suite 100 Redmond, WA 98052 Main (425) 449-4704 | Fax (425) 449-4711 www.esnw.com FIELD REPORT Project No. 7945.04 Page 1 of 3 Report ID 7945.04 E 2023 0619 Date Mon 6/19/2023 Weather 60°F Cloudy Arrival/Departure Time(s) 11AM; 12PM Travel Time (hr) 1.0 Project Name Canopy Property Location 4130 Lincoln Ave NE, Renton ESNW Rep. & Phone Willem Scherwin | 206 793 8569 Client Info/Contact Century Communities | Stacia Bloom General Contractor Info/Contact Contractor #2 Info/Contact Reviewed By LAC Initials/Date RAC Initials/Date Field Supervisor Project Manager Limitations: The presence of our field representative at the site is to provide our client with a source of professional advice, opinions, and recommendations based upon the field representative’s observations and testing of the contractor’s work. Our services do not include supervision or direction of the contractor, their employees, or agents. Geotechnical recommendations for obtaining project objectives may be made by our representatives; however, direction of the actual work should come from the owner or contractor, as appropriate. The contractor is responsible for complying with the contract documents at all times, regardless of the presence of our field representative. Jobsite safety, including compliance with all applicable state or federal regulations, is the sole responsibility of the contractor. The observations, recommendations, and conclusions provided in this field report are preliminary until reviewed by the ESNW project manager. ESNW rep was onsite to observe Redi-Rock wall foundation keyway and backfill and collect proctor. Redi Rock Wall Observations While onsite, ESNW rep observed the contractor cutting a wall keyway approximately 6 feet in width into native brown silty sand with gravel. ESNW rep used a ½” steel T-probe to probe the keyway and observed it to be very dense, firm, unyielding, and suitable for the construction of the proposed wall. ESNW rep observed the contractor placing Redi-Rock wall blocks along the keyway that has been capped with 5/8th inch minus. Rep observed the contractor had placed a 4” corugated drainage pipe behind the wall and backfilled it with pea gravel. 10XT Miramax Geogrid was placed approximately every two blocks. 5/8th inch clean was placed approximately 2’ behind the wall blocks. Imported gravel barrow was placed in 12” lifts behind the wall and compacted with a diesel sled compactor. ESNW rep took compaction tests and observed adequate compaction of at least 95% of the modified proctor at the tested locations. Please see attached site plan illustrating wall construction area, as well as table below. Proctor Collection While onsite, ESNW rep collected a proctor of brown sandy silt with gravel for lab analysis. Test Number Test Location Elevation Reference Proctor Maximum Dry Density (pcf) Test Moisture (%) Test Dry Density (pcf) % of MDD 143 Redi-Rock Wall Backfill -4 8 137.8 8.1 131.0 95 144 Redi-Rock Wall Backfill -4 8 137.8 8.6 130.5 95 Report ID 7945.04 E 2023 0619 Page 2 of 3 Earth Solutions NW, LLC Wall Construction Keyway/Backfill 143 144 Report ID 7945.04 E 2023 0619 Page 3 of 3 Earth Solutions NW, LLC