HomeMy WebLinkAboutAPPROVED_Renton Skattum Plat Civil_230630PUBLIC106TH AVE SELOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8PUBLICSE 172ND ST108TH AVE SE
0GRAPHIC SCALE201020SCALE: 1" = 20'LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055PLAT COVER SHEETTED-40-4041
R-404101””C:18-006046 PR:17-000022VICINITY MAPPROJECT DATAPROJECT TEAMLEGAL DESCRIPTIONHORIZONTAL DATUMVERTICAL DATUMSHEET INDEXPLAT CONDITIONS OF APPROVALSITELEGENDJDing 06/21/2023CURRENT PLANNINGDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023REGIONAL FIRE AUTHORITYcthomas 06/22/2023APPROVEDCONDITIONS OF APPROVAL:1. Field locate ditch and structure atsite outfall connection to ensureminimum 6" cover over pipe at alllocations. see sheet 6 of 19.2. DI pipe required for minimum cover atall locations with less than 2' of cover.ITEMS REQUIRED PRIOR TO NOTICE TOPROCEED FOR CONSTRUCTION:1. Provide updated bond quantityworksheet based on final engineeringdesign.2. Payment of all fees associated withthe Civil Construction Permit.3. A permit bond is required based on thefinal bond quantity worksheet.4. Authorization of specialized billingcontact.5. Business and Contractor's licensesfor the contractor and subs.6. Insurance certificates meeting City ofRenton minimum requirements and namingthe City as additionally insured.7. DOE NPDES Construction StormwaterGeneral Permit Coverage.8. Approved Soos Creek Water and Sewerplans.9. Pre-Construction meeting to be heldwith applicant and contractor prior toconstruction.10. Final Plat presubmittal to CityDevelopment Engineering departmentprior to construction.PROJECT NOTES:1. A building permit is required for thestormwater vault and all walls over 4' inheight (including wall footing).2. A franchise permit is required forundergrounding of overhead utilities.SURFACE WATER UTILITYjfarah 06/22/2023
PUBLIC
106TH AVE SE
0GRAPHIC SCALE201020SCALE: 1" = 20'LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 2
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055TEMPORARY EROSION & SEDIMENT CONTROLCLEARING, TREE RETENTION, & REPLACEMENT PLANTED-40-4041
R-404102C:18-006046 PR:17-000022NOTESCONSTRUCTION SEQUENCESEE TREE PROTECTIONNOTES SHEET 11JDing 06/21/2023CURRENT PLANNINGDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
PUBLIC106TH AVE SE
LOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 80GRAPHIC SCALE201020SCALE: 1" = 20'LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 3
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055GRADING PLANTED-40-4041
R-404103C:18-006046 PR:17-000022DRIVEWAY TABLE:DEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
PUBLIC
106TH AVE SE
LOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8PUBLIC106TH AVE SEPUBLICSE 172ND ST0GRAPHIC SCALE201020SCALE: 1" = 20'LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 4
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055ROAD & DRAINAGE CONTROL PLANTED-40-4041
R-404104C:18-006046 PR:17-000022 IMPERVIOUS SURFACE TABLE:CROSSING TABLE:DEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023SURFACE WATER UTILITYjfarah 06/22/2023
PUBLIC106TH AVE SE
LOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8PUBLIC106TH AVE SEPUBLICSE 172ND ST0GRAPHIC SCALE201020SCALE: 1" = 20'LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 5
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055WASTEWATER & WATERUTILITY PLANWWP-40-4041WTR-40-4041
W-404101S-404101C:18-006046 PR:17-000022NOTE:DEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 6
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055STREET PROFILES & DETAILSTED-40-4041
R-404105C:18-006046 PR:17-000022 CROSSING TABLE:DEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023condition ofapproval: di piperequired for minimumcover.condition ofapproval: fieldlocate ditch andstructure to ensureminimum 6" cover overpipe at all locations.
PUBLIC106TH AVE SE LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 7
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055DETENTION TANK DETAILSTED-40-4041
R-404106C:18-006046 PR:17-000022NOTERESTRICTOR SPECIFICATIONSINTERCEPTOR TRENCH DETAILDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023SURFACE WATER UTILITYjfarah 06/22/2023
LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 8
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055ADA WHEELCHAIR RAMP PLANSTED-40-4041
R-404107C:18-006046 PR:17-000022DEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 9
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055CITY OF RENTON STORMWATER DETAILSTED-40-4041
R-404108C:18-006046 PR:17-000022DEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023SURFACE WATER UTILITYjfarah 06/22/2023
LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 10
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055ROAD SECTIONS,CITY OF RENTON DRAINAGE NOTES & DETAILSTED-40-4041
R-404109” C:18-006046 PR:17-000022DEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023SURFACE WATER UTILITYjfarah 06/22/2023
LUA 16-0009811700 NW GILMAN BLVD, STE 200ISSAQUAH, WA 98027PHONE: (425) 821-5038Know what'sCallbelow.before you dig.RRenton Subdivision
Renton SubdivisionSheet 10
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055CITY OF RENTON EROSION CONTROL DETAILSTED-40-4041
C:18-006046 PR:17-000022“– ” ’R-404110TREE PROTECTION MEASURESDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
DEVELOPMENT ENGINEERING
Michael Sippo 06/22/2023
TRANSPORTATION OPERATION
cbarnes 06/29/2023
DEVELOPMENT ENGINEERING
Michael Sippo 06/22/2023
TRANSPORTATION OPERATION
cbarnes 06/29/2023
DEVELOPMENT ENGINEERING
Michael Sippo 06/22/2023
TRANSPORTATION OPERATION
cbarnes 06/29/2023
PUBLIC106TH AVE SELOT 1LOT 2LOT 3LOT 4LOT 6LOT 5LOT 11TRACT ALOT 10LOT 9LOT 7LOT 8LandscapeArchitectureAOAEnvironmentalPlanning &Office (425) 333-4535PO Box 578Carnation, WA 98014Fax (425) 333-4509Altmann Oliver Associates, LLCLUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 15
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055LANSCAPE PLANR-404111TED-40-4041
PR:17-000022C:18-006046JDing 06/21/2023CURRENT PLANNINGDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
LandscapeArchitectureAOAEnvironmentalPlanning &Office (425) 333-4535PO Box 578Carnation, WA 98014Fax (425) 333-4509Altmann Oliver Associates, LLCLUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 16
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055PLANT SCHEDULE & DETAILSPR:17-000022C:18-006046R-404112TED-40-4041
JDing 06/21/2023CURRENT PLANNINGDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
LandscapeArchitectureAOAEnvironmentalPlanning &Office (425) 333-4535PO Box 578Carnation, WA 98014Fax (425) 333-4509Altmann Oliver Associates, LLCLUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 17
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055CONSTRUCTION SPECIFICATIONSPR:17-000022C:18-006046R-404113TED-40-4041
JDing 06/21/2023CURRENT PLANNINGDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023
PUBLIC106TH AVE SEPUBLIC106TH AVE SEPUBLIC106TH AVE SE
HAND-TRENCH ONLYIN EXISTING TREE ROOTZONES, TYP.FINAL CONTROLLER ANDRAIN SENSOR LOCATIONS T.B.D.LOCATE MAIN LINEAND VALVES ATBACK OF SIDEWALK, TYP.16.611"312.51"12.741"511.51"11.961"79.441"816.01"9.7921"12.691"7.53101"14.9111"10.6121"SYMBOLMANUFACTURER/MODEL/DESCRIPTIONToro O-T-570Z-06P-PR 5 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 8 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 10 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 12 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 15 SeriesShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro O-T-570Z-06P-PR 4X Strip SprayShrub Spray, 6" Pop-Up, with Built In-Riser Pressure Regulator.Also includes the Zero Flush Wiper Seal. 1/2" Female-ThreadedInlet. Precision Series spray nozzles.Toro PRN-TA, TF 570Z-4P-COM ADJTurf Precision Series Rotating Nozzle on 4" pop-up riser, withcheck valve. Adjustable or 360 as indicated.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONToro 252-26 GlobeElectric, 1", 1-1/2", and 2" In-Line Plastic Remote Control Valve.Includes Flow Control. Globe Body Configuration.Debris-Resistant Valve.Rain Bird 33-DLRC3/4" Brass Quick-Coupling Valve, with Corrosion-ResistantStainless Steel Spring, Locking Thermoplastic Rubber Cover,Double Track Key Lug, and 2-Piece Body.Matco-Norca 759Brass Shut Off Ball Valve, 1/2" to 4". Two Piece Body, Blow-OutProof Stem, Chrome Plated Solid Brass Ball, Threaded, withPTFE Seats. Same size as mainline pipe.Toro P220-26-0 GLOBE 1"Electric, 1", 1-1/2", 2" and 3" Plastic In-Line Master Valve.Equipped to withstand pressure up to 220 PSI. Filter screen on2" and 3" models. Standard Solenoid. Globe Body Style.Zurn 500XLPressure downstream required is 56.84 PSIZurn 350XL 1"Double Check Valve Assembly w/ EZSwap insert.Hunter XCH-1200-SSElectromechanical controller, 12 stations, outdoor model,battery-powered. Stainless Steel Cabinet. Forresidential/commercial use.Hunter XCHSPOLESteel Mounting Pole, 4`. Comes with outdoor stainless steelcabinet for XCH-SS controllers. Required SCHSPB mountingbracket.Hunter MINI-CLIKRain Sensor, mount as notedWater Meter 3/4"Irrigation Lateral Line: PVC Class 200 SDR 21Irrigation Mainline: PVC Schedule 40Pipe Sleeve: PVC Schedule 40IRRIGATION SCHEDULE1.THIS PLAN IS DIAGRAMMATIC ONLY. VERIFY ALL DIMENSIONS AND ELEVATIONS IN FIELD. ADJUSTEQUIPMENT LAYOUT TO SUIT FIELD CONDITIONS AND SITE CONSTRAINTS.2.EQUIPMENT SHOWN IN PAVED AREAS OR OUTSIDE PROJECT LIMITS IS FOR GRAPHIC CLARITY ONLY.INSTALL IN LANDSCAPED AREA. DO NOT WILLFULLY INSTALL EQUIPMENT UNDER PAVEMENT OROUTSIDE PROJECT LIMITS.3.DESIGN ASSUMPTIONS: 22 GPM AT 70-98 PSI STATIC PRESSURE AT THE METER. VERIFY IN FIELD.4.SEE IRRIGATION SCHEDULE FOR PRESSURE REGULATING VALVE SETTING.5.ADJUST SPRINKLER ARC AND RADIUS AS NEEDED TO AVOID OVER SPRAY ONTO HARD SURFACES,WHILE MAINTAINING PLANT COVERAGE.6.COVER DEPTH: MAIN LINE--18 INCHES; LATERALS--12"; SLEEVES--36" UNDER VEHICULAR CROSSINGS,24" UNDER WALKWAYS.7.PIPES MAY SHARE TRENCHES. PROVIDE 4" LATERAL, AND 6" VERTICAL SPACING BETWEEN PIPES.8.USE CARE WHEN TRENCHING IN EXISTING TREE ROOT ZONES. HAND TRENCH ONLY. TUNNEL UNDERROOTS GREATER THAN 2" DIAMETER. CLEANLY ROOT PRUNE SMALLER ROOTS. BACK FILLIMMEDIATELY OR COVER WITH DAMP BURLAP.9.HYDROSTATIC PRESSURE TESTS: WITH THE MAIN LINE PURGED OF AIR AND FILLED WITH WATER,PRESSURIZE TO 150PSI. IF PRESSURE LOSS IS GREATER THAN 5PSI AFTER 60 MINUTES, REPAIRSMUST BE MADE AT CONTRACTOR'S EXPENSE AND SYSTEM RE-TESTED. WITH ALL LATERAL LINESPURGED OF AIR AND ALL RISERS/SWING JOINTS CAPPED, FILL SYSTEM WITH WATER AT LINEPRESSURE. IF PRESSURE LOSS IS GREATER THAN 5PSI AFTER 30 MINUTES, REPAIRS MUST BE MADEAT CONTRACTOR'S EXPENSE AND SYSTEM RE-TESTED. NOTIFY LANDSCAPE ARCHITECT OF TESTSCHEDULE 72 HOURS PRIOR TO TESTING.NOTESNUMBERMODELSIZETYPEGPMPSIPSI @ POCPRECIP1Toro 252-26 Globe1"Shrub Spray16.6235.549.70.93 in/h2Toro 252-26 Globe1"Shrub Spray9.7935.145.10.97 in/h3Toro 252-26 Globe1"Shrub Spray12.535.848.10.88 in/h4Toro 252-26 Globe1"Shrub Spray12.7335.548.10.92 in/h5Toro 252-26 Globe1"Shrub Spray11.5134.647.60.93 in/h6Toro 252-26 Globe1"Shrub Spray11.9437.850.30.96 in/h7Toro 252-26 Globe1"Shrub Spray9.4434.945.90.98 in/h8Toro 252-26 Globe1"Shrub Spray15.9537.353.10.9 in/h9Toro 252-26 Globe1"Shrub Spray12.6135.347.60.89 in/h10Toro 252-26 Globe1"Shrub Spray7.5333.943.60.88 in/h11Toro 252-26 Globe1"Turf Rotary14.8746.360.40.52 in/h12Toro 252-26 Globe1"Shrub Spray10.5637.648.81.11 in/hVALVE SCHEDULELUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055IRRIGATION PLANJDing 06/21/2023CURRENT PLANNINGDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023R-404114
DCVA IN VALVE BOX12334456FEBCO 850 DCVASIZE PER PLAN1VALVE BOX AND EXTENSION;SIZED FOR ADEQUATECLEARANCE AROUND DCVAFOR MAINTENANCE2SCH 80 UNIONS (2)3SCH 80 NIPPLES4SCH. 40 MALE ADAPTERS (2)5MAINLINE PIPE PER PLAN674" WASHED DRAIN ROCK7GEOTECHNICAL CLOTH8BRICK OR PAVER, ONE ATEACH CORNER9891NTSMASTER CONTROL VALVE32 8406.23-652NTSQUICK COUPLING VALVE IN BOX332 8406.43-14NTSBRASS ISOLATION VALVE432 8406.33-12NTSTURF SPRAY FLEX ASSEMBLY532 8403.13-08NTSSHRUB SPRAY FLEX ASSEMBLY32 8403.26-126REMOTE CONTROL VALVE WITH THREADED UNIONSNTS732 8406.13-19SLEEVE DETAILNTSSLEEVE WITHWIRE32 8409.76-20812NOTECONTROLLER SHALL BE HARD-WIRED TO GROUNDED110 VAC POWER SOURCE34IRRIGATION CONTROLLER (XCH-SS) PER PLANSTAINLESS STEEL POLE AND MOUNTING BRACKET1FINISHED GRADECONCRETE234HUNTER XCH CONTROLLER ON STEEL POLENTS10LUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055IRRIGATION DETAILSFINISH GRADESTANDARD VALVE BOXPRV AS SPECIFIEDMAIN LINEFEMALE ADAPTERSCH. 80 NIPPLES (2)6" WASHED GRAVEL SUMPLANDSCAPE CLOTH-WRAP UP SIDESPRESSURE REDUCING VALVENTS9LUA 16-000981UTILITIES UNDERGROUND LOCATION CENTER(ID,MT,ND,OR,WA)811CALL 3 WORKING DAYS BEFORE YOU DIGSAFETY PRECAUTION SHALL BE IMPLEMENTED BYCONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCEWITH CURRENT OSHA STANDARDSELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SURVEY - PINKTEL/CATV - ORANGE PROPOSED - WHITE WATER - BLUERenton Subdivision
Renton SubdivisionSheet 1
Renton Subdivision17018 & 17022 106th Avenue SERenton, WA 98055IRRIGATION DETAILSJDing 06/21/2023CURRENT PLANNINGDEVELOPMENT ENGINEERINGMichael Sippo 06/22/2023R-404115