HomeMy WebLinkAboutS-422904A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
LEGEND
CV
N
CV
I
n
rr
C')
CV
CV
CV
r�1
L; i
Q
Z
8
RIM=22.06
IE=16.44, 6"PVC E
IE=16.36, 6"PVC W
"NO PARKING"
2
O
"NO PARKING"� 5 e
FIN41PA,1I?': 049S
IE=17.97, 12 CPP W
SANITARY POINT F CONNECTION
PER MECHANICA . INVERT ,3 0Q',
BELOW FINISH LOOR, IO
12.36 I
FORCEMAIN L Py ��0� 2396 2
STORM CATCH BASIN
TYPE I
RIM=23.66
IE=19.65, 12 "CPP N
IE=19.76, 12 "CPP E
IE=19.76, 12 "CPP S
IE=20.38, 6"PVC W
STORM CATCH BASINfi
TYPE I
RIM=22.55
IE=20.28, 6"PVC W
IE=20.02, 12"CPP N
i
to wl
HALT
_ w
VHOI F
TELEPHONE
RISER
FIRE DO
NST�I
M OF
VAULT IS
[{IN
SEPARA
EFIRg
ERMIT
G
42"
"WATER LINE"
x 21i RED "HAZARD"
�� I0 � -
G�
�V eG��
--d��w�
�o
ti� �Q•tt,,� � goo
vJ
k
40,, 0
N
7&8" OAS —
1
WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN (PRIVATE)
SCALE: 1 "=20'
• Call 811
• m two business days
before you dig NO.
REVISION
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE AP P R APPROVED:
DCD
s I —
S
oNr- "NO PARKING"
CHAINLINK FENCE
x —STORM VAULT W/OIL WATER SEPARATOR
3 LIDS. UNABLE TO OPEN 2 OUTER LIDS
RIM=24.08
TOP OF BAFFLE=21.78
TOP OF VERT. TEE=21.55,
BOTT. OF VERT. TEE=18.58, 12"PVC W
TOP OF PIPE=20.9f, 12"PVC E,
UNABLE TO MEASURE IE
WATER LEVEL=19.98
BOTT. OF STRUCT.=17.53
I
TPN 3340402755
AZULq PROPERTIES LLC
I I
I
)
VACATED R RENTON I
5 8 PER CITY OF 4668
�RDINANCE 0j150313
REC.
NO 1997
29
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE IN,
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
NORTH
HORIZONTAL SCALE: 1"=20'
20 0 20 40
C TY OF
RENTON
PROPOSED FEATURES-
W
DOMESTIC WATER
SERVICE
F
FIRE SPRINKLER SERVICE
WATER METER
FIRE DEPARTMENT
CONNECTION
W
FIRE HYDRANT
SS
SANITARY SEWER
PIPE
®
SANITARY SEWER
MANHOLE WITH ACCESS LOCATION
•
SANITARY SEWER
CLEANOUT
N
GATE VALVE
►
THRUST BLOCK
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND
WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C,
RESPECTIVELY.
3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION.
8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK
INSTALLATION.
9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON
FORCES.
KEY NOTES
2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.3C.
:� 6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD.
PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT.
B� 6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN.
4� 2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN.
5� 6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK.
%" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C.
7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD.
PLAN 340.8/C5.3C.
SEE L2.00 FOR IRRIGATION PLAN
OIL WATER SEPARATOR PER DETAIL 500/C5.2C
10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C
11 INSTALL RPBA PER STD PLAN 350.2/C5.4C
12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE
THRUST BLOCK
C.
O� pF WA,1 f
r
-r
46449
�O�c C1
'IV
�ss10,vA,
�M.
6,u9ij sitts&hill
CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
S-422904 I W-422902
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING A018t&�'
IL
NJanders 05/08/2023 %jl
WASTEWATER UTILITY
jstowell 05/09/2023
BROTHERTON CADILLAC - RENTON
Plan ning/Building/Public Works Dept. WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN
(PRIVATE)
DATE:
FIELDBOOK:
PAGE:
C5.0C
SHEET: OF:
27 39
N
T
O
O
I
N
,i1
Ln
CV
T
O
O
N
Q
J
LO
O
O
N
CV
A
u