A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3878A3 DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 DocuSign Envelope ID 3458681D-914F-4F2D-AB59-7C192D3B78A3
WASTEWATER UTILITY STANDARD NOTES
1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY
OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS 8 SPECIFICATIONS
A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION
2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL
SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS
AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS
3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS,
INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED
BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC
WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION
4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC
CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY
5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND
FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL,
STATE AND FEDERAL REQUIREMENTS.
6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE
THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE
OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR
SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES
7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH
OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF
MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE
EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19).
8 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034, SDR 35,
C900/C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY
9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC)
UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL,
BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE
OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412
10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE
BACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY
COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY
11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH
THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS
AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS 8
SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED
ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN
405
12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF
THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE
COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL
13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER
SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED
PROFESSIONAL SURVEYOR
S , PLAN - 413
• PUBLIC WORKS WASTEWATER UTILITY APPROVED
DEPARTMENT STANDARD NOTES Martin PastuchaO/26/2
DATE
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
ALL 90 TURNS SHALL BE ACCOMPLISHED
4" BEND AS REQUIRED (NO GREATER
BY MEANS OF A WYE WITH CLEANDUT AND
45 BEND TWO 45' BENDS SHALL NOT BE
THAN 45- BEND) EVERY 2ND CHANGE 4" CLEANOUT WYE WITH
ACCEPTABLE (SEE NOTE 11)
IN DIRECTION OR GRADE WILL REQUIRE 45 BEND AND PLUG
A CLEANOUT WYE (SEE NOTE 11) I (SEE NOTE 11)
HOUSE
I
a
HOUSE
�I
a
HOUSE
gl
a
HOUSE
3
-0" MIN
4" SEWER PIPE
SURFACE CLEANOUT
4" SURFACE
(TYPICAL)
6"x 6"x6" 1YYE
CLEANOUT
4" SEWER PIPE. SEE NOTES 2
(SEE STD PLAN - 407)
WYE
�4"
�4' TEST TEE WITH
AND 3 MINIMUM UNE SIZE FOR
1
WYE PITH
PLUG FACE UP
OTHER THAN SINGLE FAMILY IS 6"
R O W LINE
CLEANOUT
(TYPICAL) - I
ROW LINE
-
3' MIN
6"x 4" REDUCER a
F z
(TYPICAL) z
MAIN SEWER LINE
NOTES
_z IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING
FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION
I PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, A
a OF THE NEXT UPSTREAM MANHOLE COVER OF THE
SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF
o PUBLIC SEWER SYSTEM, A BACKFLOW PREVENTION
RENTON PUBLIC WORKS DEPARTMENT.
0
c DEVICE SUCH AS CLEAN CHECK EXTENDABLE
'^
BACKWATER VALVE OR APPROVED EQUAL SHALL BE
INSTALLED
2 FOR INSPECTION OF SIDE SEWER, CALL 24 HOURS IN ADVANCE
m
THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER PERMIT
4" FLEXIBLE COUPUNG (FERNCO OR EQUAL)
SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE
ON SITE WHEN INSPECTOR ARRIVES AT APPOINTED TIME DO NOT
BACKFILL THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
rn SURFACE CLEANOUT
m
4"x 4"x4" WYE
3 SIDE SEWER PIPE AND FITTINGS SHALL BE PVC SDR 35 WITH RUBBER
4" PIPING
GASKET JOINTS UNLESS OTHERWISE APPROVED BY THE PUBLIC
PLAN
WORKS DEPARTMENT
BUILDING DRAIN FOR
4 A MINIMUM GRADE OF 2R (1/4" PER FOOT) MUST BE MAINTAINED
LOW ELEVATION HOUSE
WITH A 4" PIPE IN THE EVENT A 2% GRADE CANNOT BE MAINTAINED
WITH THE APPROVAL OF THE PUBLIC WORKS INSPECTOR, THE
MAIN TO
CONTRACTOR MAY INSTALL A 6" DIAMETER SIDE SEWER AT NO LESS
5 FEET
R 0 W LINE R 0 W. LINE TO CLEANOUT I MAX
THAN IX
SIDE SEWER
STUB
BUILDING SEWER
BUILDING
DRAIN
5 INSTALL SIDE SEWER WITH 2' MINIMUM COVER 18" COVER IS ALLOWED
3 FEET MIN I'-
AT THE HOUSE IF OUTLET IS SHALLOW
6 ALL BUILDING SEWER AND SIDE SEWERS SHALL HAVE BEDDING IN
1
ACCORDANCE WITH STANDARD PLAN 405
`•}�
�
m m - c x - > m x CA °
7 WHENEVER FEASIBLE, THERE SHALL BE A MINIMUM 5 FOOT
y i 4
HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND ALL
o m o z m m g c x v 10+ m p x
� v
�g �" Cmm'♦ $
OTHER UTILITIES
m cZi
m
O1P, y$o m 0 c z or m
8 SIDE SEWER TESTING SHALL CONSIST OF PLACING A PLUG IN THE
y z A u o y m o m z o g
z
TEST TEE AND INSTALLING A 4-FOOT RISER PIPE ON THE CLEANOUT
I c o n ti 0 C
AT THE BUILDING. THE SIDE SEWER PIPE SHALL BE FILLED TO WITH
m r�1
^�' v n
WATER TO THE TOP OF THE RISER PIPE NO LOSS OF WATER SHALL
FOR
m ? m m iti
OCCUR A PERIOD OF 10 MINUTES. THE SIDE SEWER MAY BE
= z
CONNECTED TO THE BUILDING FOLLOWING THE SUCCESSFUL
COMPLETION OF THE LEAK TEST
"O= v
9 THE CLEANOUT AT THE RIGHT-OF-WAY SHALL BE INSTALLED PER
r^ PLAN
STANDARD PLAN 4061 THE CLEANOUT AT THE BUILDING SHALL BE
BUILDING SEWER
INSTALLED TO SURFACE GRADE ALL OTHER CLEANOUTS SHALL BE
INSTALLATION
INSTALLED TO WITHIN 12" OF THE SURFACE
10 IF SIDE SEWER STUB IS NOT AVAILABLE THE OWNER SHALL BE
RESPONSIBLE FOR ITS INSTALLATION PER STANDARD PLAN 4061
ALL WORK WITHIN STREET RIGHT-OF-WAY SHALL BE DONE BY A
LICENSED AND BONDED CONTRACTOR
CALL 811 BEFORE YOU DIG
11 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC
or go to
RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
www callbeforeyoud,g org
12 ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE
WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT (1WSHA)
TYPICAL BUILDING SEWERSTD.
PLAN - 406.2
PUBLIC WORKS
DEPARTMENT
FROM PROPERTY LINE TO
JAPPf0,"Ig26/202
Martin Pastucf'��
BUILDING CONNECTION
#8@"1FD98B"9D DATE
1 12
RECESSED
LIFT POCKET
o 0 3/4" LETTERING "SEWER"
O O O O O
e SEWER e (2) BOLT SOC. (ALLEN HEAD) -
5/8" - 11 X 1 5 STAINLESS
o STEEL
REF PART #00981177
-
1-3/ 16"
SEE I
10-1/2"
5/l
1/4' 12-1/2"
J- T1-1/g,.
2-1/4"
�--- 14/ �11
1 � 12-3 4"
CAST IRON RING AND COVER
Not to Scale
FRAME
V-n,.
`-- 45- (1/8) BEND
DR
)ABLE
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTES.
1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC
No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY
2 IN UNIMPROVED AREAS, POUR A 8" THICK, S-O" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER
3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106
STD. PLAN - 403.1
PR
WORKS 8" OR 6" CLEANOUT °^` Y
DEPARTMENT FOR SANITARY SEWER MAIN Martin PastuCYJ�26/2020
BD DATE
800 TOTAL GALLON OIL/WATER SEPARATOR
CUSTOMER TO SUPPLY PIPES AND TEES.
PIPING SHOWN FOR REFERENCE ONLY.
2"0 VENT DU
2EA. 8"0 HOLES
7'-6
1 12:!
30
ENV-2
WITH
25
024
AND COVERS
NGS
20
ETER
-ET
15
Y"
IUh' SLAB WEIUHI: J,bbU Lbt). UKAWING MAY NUI UUNFUKM IU IHL
VAULT WEIGHT: 13,160 LBS. MOST CURRENT SPECIFICATION
OWS-4878 4'-0" X 6'-6" X 6'-0" (I.D.)
10 Oldcastle Precast FILENAME: ENV- 2.DWG ENVIRONMENTAL VAULT
Northern California REVISED: MARCH 2O16 OIL WATER SEPARATOR
Madera • Morgan Hill • Pleasanton. Santa Rosa. Stockton • Tulare
Phone: 925-750-6650 Fax: 925-750-6660 www.oldcastleprecast.com Copyright © 2016 o1am■.u:Pnxxsj..
W-WATER SEP,
E: N.T.S.
L• Call 811
• ® two business days 1
before you dig NO.
W (SEE NOTE 7)
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 5) ----\
FOUNDATION LEVEL
LIMITS OF PIPE ZONE
.i
0. D.
of
PIPE
31
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS
5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)
OF THE STANDARD SPECIFICATIONS
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED
7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
STD. PLAN - 405
PUBLIC WORKS PIPE BEDDING ^PP
DEPARTMENT FOR SANITARY SEWERS Martin PaStUCW26/202
ruw¢w"1".aexi.0980449D DATE
1 12
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
raj ----------
EX. SEWER MAIN I I I
I
l
PROPERTY LINE
AS NEEDED)I I I
13'-0"
MIN
WER STUB I I I'A;r
FUTURE 4" SIDE SEWER
F��SEIESR
2"x 4" STUD MARKING POST PAINTED
6- CAP WHITE WITH THE WORD "SEWER" STENCILED
EE X 6" TEE I I I
I i
IN 3" HIGH BLACK LETTERS AND M6 WIRE
SIDEWALK
i W
WRAPPED AROUND THE STUD AND
I I I
COUPLING (TYP) 1 I I
1 f I
a
EXTENDED TO THE TOP OF THE STUD
k-J L_J_L_________J
I;
6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
0
(EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
APPROVED EQUAL, SPECIFY "SEWER" ON LID),
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
CONCRETE PAD TO BE 8" IN DEPTH
BEND AS
8'
REQUIRED
EXISTING SANITARY
SEWER MAIN IN SLOPE
-3
-ruw + �1uc x7
1 6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER
`SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC k C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL)
D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC). CUT IN A NEW PVC "TEE" USING
"STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F HOPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL
MOTES
1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 25' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 % SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
SIDE SEWER STUB STD. PLAN -406.1
• PUBLIC WORKS INSTALLATION APP
'1C DEPARTMENT MartinPastuCftW26/202
VAMOF (SEWER MAIN TO PROPERTY LINE)(-wlMMJFU988"9D
DATE
I 019-M—L
In
PIPE CROSSING
STORMSTORM
PIPE CROSSING
■_■■■■■�■■■■■■■■■■■■��■■����■■■■
SEPARATION: 0.32
NO JOINTS WITHIN
OF WATER CROSSING—ENMkLmmlibmwmmmmmmm�icoloolmsolulFI
—]JJJ�M 415' BEND,1 IE: 118.311.
NFA;N�*
Now
MENE
■■
■►■■I�I■■■■■iIM71.1�!■■■■
`
•
•
1- IQ ...
■
■■■
■■
• PIPE -1
MEMEMEMEMEMEMEMEM
■■■V■■■■■liM■■■■■■
�����Mmmm
■■■■
■■
1- : :
- SEPARATION: 1.05
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
10 -0+40 -0+20 0+00
SANITARY SEWER SERVICE
CONSTRUCTION
RECORD DRAWING
PROJECT WAS COMPLETED IN SUBSTANTIAL
CONFORMANCE WITH THE APPROVED
PLANS. ELEVATION DEVIATIONS, WHERE
APPLICABLE, ARE DENOTED WITH PLAN
CALLOUT UPDATES, AND A STRIKEOUT
THROUGH THE ORIGINAL ELEVATION.
UTILITY AS -BUILT INFORMATION OBTAINED
BY MCKEE ENTERPRISES AND VERIFIED BY
SITTS & HILL ENGINEERS, INC.
30
25
20
15
1 12:
,D C.
sitts&hill
�AI�d9 I
CIVIL I STRUCTURAL I SURVEY
4 ,tw tt �c rJ:
4815 CENTER STREET I TACOMA, WA. 98409
-� PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
�ocy G1 49 'Irv
Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
S-422906
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURVEYED:
SCALE:
AS NOTED
VERTICAL: NAVD 1988
HORIZONTAL: NAD 193/183/1 991
DATU M
' CITY OF
• RENTON
Planning/Building/Public Works Dept.
BROTHERTON CADILLAC - RENTON
WASTEWATER AND WATER UTILITIES NOTES
(PRIVATE AND PUBLIC)
DATE:
DESIGNED:
DKM/RJJ
FIELDBOOK:
PAGE:
DRAWN:
KLK/DKM
ONE INCH
DRAWING NO:
C5.2C
FIELD CONDITIONS CONFLICT RESOLUTION
S&H
10.25.23
DCD
CHECKED
ATAT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
REVISION
BY
DATE
APPR
APPROVED: DCD
SHEET: OF:
29