HomeMy WebLinkAboutzS-4229setA PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
CV SANITARY SEWER MANHOLE X ti ti 3 RIM=21.33 O.W. PER CI 46 0 8 5 ss
TYPE ll a TED NICE #
' , IE=18.38, 18"CPP NE CA R• AN a _.� - 11
ss �ti 16
(� °AS�
°I Q I V RENTON ORDIN _ - SS X �� Q ��
RIM=21.49 I a ° IE=18.37, 18 CPP S _ i Ss
N IE=14.65, 8"PVC N I TE _ - sxu
IE=14.75, 8"PVC E l W CONCRESS o0 N GIE=14.71 8"PVC S "of I /J Q -' SS xti8 12 8 TI SS
GI a I Ss ��ti ASPHALT
�j STORM DRAIN MANHOLE Q s '
r „
TYPE 1 ,Z 60 ° p Fr ss s y 4X4
RIM=21.28 211 �1. 1' S0 SS �ti>RO.g.W 4683 0 _ : cAs' - F� �'I� I 4I ' F., GRAVE`. ��
ss INANCE # 0 4.. GAS- x _ �2 r p 3 . ;•.O/Yo
IE=15.21, 12 DIE "STOP" - ' ss 1g6 NTUN ORD 7112p039 ' _ _ s, GAS.'° 61 22.5s I :.�',:.:' CO ` %
IE=18.34, 18 DI S _ - w ss xti RE NO 199 A_. Ps ° CITYti p ;�3:•,. I..
" �4S ss - ASPHAL IN
I ' REC. ' G _ cAs-a p oNP- PER g SD 13 9 i ti�
R.0•
"oNP" p I s ti _ A - p , 4oNP.-. ACATLD gR INANo _ Fo \� 22.93 X � X ti" w l
�� o' . - g EN 7 I. X
w '�� sD x 216$ x y,� R x - - ' o
a s a Mu so 5ti ° .' . a p ' . CONCRETE `pso 94 5 ° p X ��1 -yam - - J I ;'' I .= WOOD
`.` STAIRS I \
° • • p �% Mu I I tit ° ONP ° ASPHALT o
i X _ SD •' 'Fo a.. W II I ��P' . .. ° p v II
� SD �0. ' 2�y+c W �.,. 10 p' P_ ' .�g� / po .o _ ° a !� _ �$ ..•:
w , oN x� r p D ' a I: t EXIST G
__aGAs_-�o N°o _ a pop: GRA��g, _ �95 I BUILDNG TT
Y Y ' I \ L GAS a a' F BA(
ti0�0 - IJ AVE _ _ 1Q �� I �' - - pa a Ti. STORM DRAIN MANHOLE o I
ECON _ II I <10 ti ° TYPE II I STORM CATCH BASIN 5&12" CEDAR \
l GAS' �1� .p ONP' J p� RIM=22.92 I TYPE I III I
ASPHALT _ 0' I I P \ go �' 6�l'� ,,`L�` IE=19.76, 8"PVC SE I RIM=22.49 I \
\N �1 " IE=17.10 15"CPP SW IE=20.34, 12 DI N STORM CATCH BASIN RETAINING
BR THEPTON" ' I 14 CED WALLS
"S�(t1 1 20 ti N 5 I 60 I IE=18.69, 12 "CONC E TYPE 1 m
"EMPLOYEE OFp�a STORM DRAIN VAULT I IE=18.46, 15"CONC W I RIM=23.55 2?,�I WOOD YARD
0 PARKING ® x iFO 1 ti TYPE 11 IE=18.02 12"CPP S NI 6 Fz1 STAIRS- -
t THE MONTH" �; DRAIN
m / 0 g RIM=23.59 TOM DRAIN MANHOLE IE=17.97, 12"CPP W I I (CONCRETE I
SD I 1 g5 IE=19.14 15 CPP NW
SD 20' I m I I 116 /CISTAIRS TO
DEAD END l o
° STORM CATCH BASIN I RIM=22.11 I o �. 2 6
MONUMENT POSITION 1 I E' � I I I TPN 3340402820 , / BA �T ;.:...�,
10 BAY
STORM CATCH BASIN tit TYPE I A & D RENTON LLC IE=14.51, 4 PVC SE
OF SURVEY TYPE I x \ o �5 / \ / I RIM=20.89 I BOTTOM STRUCTURE= 12.36 I DOOR
9404079012 I cC 113. \ ° .
OR, NOT FOUND RIM=20.18 10 gg �1 o IE=19.23, 12"CPP SW 3 PVC, PUMP WITH FORCEMAIN E Q00 2396 rya I I LS `'..GRAVELt..� I
IE=17.72, 18 CPP E I x�' 0 �• tip• m y N
IE=17.46, 16"CPP S I � g9 o I I 16 eP I I Iv ^ 9 J 22 WA TEA
TPN 33 �4?J2850 EXISTING I 23.70--
3. EMPTY
IE=17.35, 12 CMP W 6g I I
5 MAP 23."
BROTHERTO �ADILLA Lu. �� g BUILDING
STORM CATCH BASIN TEL TEL �j1 0 CONDUIT I•,� _)_ \�1 a '
TYPE I CIOI ti060 II I ti '� I o 10"I
RIM=20.93 I aX NI 2g8 �' `': I 2X1&4X2 SD" L so �1 PIN
IE=18.16, 18"CPP N I I a o 0 23.28 -- / 2
IE=18.33, 12"CPP E I X�p96 ti6 CO YARD DRAIN I �-� 8 5 I P
IE=18.19, 18"CPP W I I I X o �0 1 ti� 23• TOP RIM=23 DEBRIS 15.92con .10 � I u- I 9
I 3 I m ASPHALT o t o �9 0 00 F.=24.04' - X ti�1 I I I Ifx 211 �11
1 I ASPHA T 1 I ' o
O x I I' ti05 I I I 23 0 I z
`l1� �x �' I �
N 3 o 6 F.F.=23.88 I STORM CATCH BASIN I I I I 6 STAIRS
\_
STORM CATCH BASIN ONCRETE 1 �5 0_ � � I ACCES:
I g 6 5 � 6g m � � RIMTYPE23.66 I � �� � I ��2 BASEMI
RIMTYPE20.48 I vN x 6 0 6 0 1® x15 ' IE=19.65, 12"CPP N o_
I a6 16 'y55 IE=19.76, 12 CPP E w I I I \
IE=19.30, 8"DI S � tio• �• ti 6 z I I I RE INI G
10 x I i X I\ I1 VACATED R•REN N ' IE=19.76, 12 CPP S I¢ N
�1. I N ti 11 a PER CITY OF ' I I IE=20.38, 6"PVC W I I I i I I WA
1 313
SO I I II I 55
19970� SIDE SEWER SCOPE 1S I I I / o I I I I I YARD
I N
STORM CATCH BASIN( I I I ti 6 o UNDER PERMIT -24.00 I I I I DRAIN
TYPE 1 ��� 0 - SS23002346 :- sD I li I I I BUILC
1 I 3 ^�� � \ 2 �� r' TPN 3340402885
RIM=21.65 Nix `� BROTHERTON CADILLA STORM CATCH BASIN I I I I I I
IE=18.74,12 DI SE N I /a - - SS - 23LF-6" DIP @ 7.66% TYPE I ASPHALT I
IE=18.54, 12"CPP NW I I /N ® B-SSCO04 6" CO \ 23LF-6" DIP @ 12.47% I RIM=22.55 IL I _ I ��• -
I `�' \ N:174,127.70 I IE=20.28, 6"PVC W
'NO PARKIN E:1,297,167.31 \\I I� ° / B-SSC003, 6" CO I I IE=20.02, 12"CPP N 13 ❑9 I I I /�
STORM CATCH BASIN I i 9� \ RIM:23.12 / N:174,127.12
RIM=20.62 I /� \ / IE:19.31 6" SE (IN)� E:1,297,190.30 I I I I i I 0�
IE=19.03, 8"DI N ��16x� I a6 �6 $ Igo IE:19.31 6' E (IN) RIM:23.93 I I I II /
IE=18.69, 12 DI SE x a I IE:19.31 6 N (OUT) IE:22.18 6 E (IN)
IE=18.70, 12"DI NW I 7LF-6" DIP @ 7.66% IE:22.18 6" W (OUT) I I I II 6&2�
II "� B-SSCO02, 6" CO
STORM CATCH BASIN I 2�
N:174,122.57 I I
TYPE 1 I U � ;° ti E:1,297,172.18
RIM=23.25 1tik R 2LF-6" DIP @ 17.58% 1 I I'Y.'..:`::y.:'::..•
IE=17.89, 12"CPP N 51x IIx2 AJ / RIM:23.29 \ I x�
„ o IE:19.85 6" E (IN) / 2LF-6" DIP @ 15.81%
IE=17.86, 12 CPP SW I
6g �' IE:19.85 6 NW (OUT) / ��:;. :. II NO PARKING .
x \ B-SSCO01, 6" CO 3 '�
Q �1a 9LF-6" DIP C 7.66% \ N:174,122.12
J o B-SS OWS, (PER MECHANICAL) eA \ E:1,297,190.18 z
N:174,122.35 a1RIM:- / O[
T I o E:1,297,181.18 23.93 / ��� w w 5$ b op
r� x21k3 �I RIM:23.61 \ IE:22.21 6" E (IN) 7 11 c, ,,"
79
y6 X I I( I Q k IE: 20.79 6" E (IN) \ IE: 22.21 6" W (OUT) I N w w X I?- 6
I IE:20.54 6" W (OUT) ASPHALT Q w
1.,
I I\ oa�lgn3 �� \ 9LF-6" DIP @ 15.81% _ W
I ��x \ _
, �. CONIC l _ g
NI nN 16 • 11 O R _ _ W - ' W I � „NO �g6
,��5• \ ti�� W P Xl
V 5 _ w titi' - 23-
X a 0 p P_ w01 __ 6
6' 1• I 8 ly'
X � I O �cay „ X 1 23 � ' W /� �� SS �� l
LEGEND
PROPOSED FEATURES -
SS SANITARY SEWER PIPE
® SANITARY SEWER MANHOLE WITH ACCESS LOCATION
• SANITARY SEWER CLEANOUT
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.26.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) NOTES ON
SHEETS C5.26.
3. SEE STD. PLAN 403.1/C5.2B FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2B FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2B FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2B FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
KEY NOTES
OIL WATER SEPARATOR PER DETAIL 500/C5.2B
:� CONFIRM INVERT ELEVATIONS OF EXISTING SANITARY CLEANOUT
sitts&hill
6 MA E w g[I OF VP CIVIL I STRUCTURAL I SURVEY
/ A T 3 \ 5 y ��. 23 eP w X ��' i ss TELEPHONE q rJ+
51 \ \ x 1� N ' ss RISER ' C 4815 CENTER STREET I TACOMA, WA. 98409
I / �ti• I x W ��g�j ' SS 40 N f 1 V PHONE: (253) 474-9449 I FAX: (253) 474-0153
W %< g1 N SANITARY SEWER MANHOLE ' ` http://www.sittshill.com/
SANITARY SEWER MANHOLE Q I 3 x w SS TYPE II -
TYPE II � I I I , , _ 4' - x ' ss ' 66 .. RIM=23.23 _ •�y ♦6449 �of ,y? Project No.: 19480 Project Mgr.: DCD
RIM=22.92 I cD , w 6 gs 2 15 MAPLE IE=17.07, 6„PVC E Or►1S[E �' `"
'� rig
IE=15.70, 8 PVC N �L6gx al X
IE=15.85, 8"PVC E
. 13TH ST. 5
S.W I
AVE,)JW,L)� I
STORM
' � Q
CATCH BASIN
TYPE 1
RIM=22.71 6/
IE=16.69, 18"CMP N x ti�5
it 414n hlr I -I
L; i
z
so - `, 1P ..tip F• ��� tik IE=11.01, 6 PVC 3 oNAI £ Prot. Engineer: DKM/RJJ Prot. Drafter: KLK/DKM
g �61 W o �xti� iss GRPV��✓PLE��15" MAPLE "24 'IE=17.19, 8"PVC W
__ p
SS PARKING"- - 0
v
Ss 1
1 "NO
SS ss g S-422901
s s titi56 x 22� , :,TF � OEPARKING" �ACA CITY
ITYROF RENTON
s x --2 PER CIT CE #4610 4 IN COMPLIANCE WITH CITY OF RENTON STANDARDS
�� 5g '
��' ORDIN N� 1996p614028
1g xti20`���i _ ' REC. DEVELOPMENT ENGINEERING
\ �o
Wanders 05/08/2023
220 x� STORM CATCH BASIN NORTH
x I TYPE I
(PRIVATE) HORIZONTAL SCALE: 1"=20' rWA$TEWATER UTILITY
GRADING AND STORM DRAINAGE PLAN
` � 20 0 20 40
SCALE: 1 "=20'
• Call 811
• m two business days
before you dig NO.
REVISION
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE AP P R APPROVED:
DCD
jstowell 05/09/2023
SCALE: DATE:
VERTICAL: NAND 1988• BROTHERTON BUICK-GMC - RENTON
AS NOTED HORIZONTAL: NAD 1983/13/1991 C T Y OF
FIELDBOOK:
RENTON PAGE:
° ONE INCH DATUM DRAWING NO:C5.013
�� • O ^
AT FULL SCALE Plan ning/Building/Public Works Dept. WASTEWATER UTILITIES CONSTRUCTION PLAN (C,/ I13
IF NOT ONE INCH
SCALE ACCORDINGLY (PRIVATE)
SHEET: OF:
21 29
N
T
O
O
N
'i1
N
T
O
O
N
Q
J
LO
O
O
N
CV
A
u
DocuSign Envelope ID 345B681D-914E-4F2D-AB59-7C192D3B78A3
WASTEWATER UTILITY STANDARD NOTES
1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY
OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS 8 SPECIFICATIONS
A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION
2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL
SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS
AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS
3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS,
INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED
BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC
WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION
4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC
CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY
5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND
FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL,
STATE AND FEDERAL REQUIREMENTS.
6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE
THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE
OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR
SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES
7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH
OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF
MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE
EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19).
8 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034, SDR 35,
C900/C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY
9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC)
UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL,
BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE
OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412
10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE
BACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY
COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY
11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH
THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS
AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS 8
SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED
ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN
405
12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF
THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE
COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL
13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER
SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED
PROFESSIONAL SURVEYOR
ST P. PLAN - 413
PUBLIC WORKS WASTEWATER UTILITY APPROVED
DEPARTMENT STANDARD NOTES Martin Pastucha<O/26/2
DATE
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
ALL 90 TURNS SHALL BE ACCOMPLISHED
4" BEND AS REWIRED (NO GREATER
BY MEANS OF A WYE WITH CLEANOUT AND
45 BEND TWO 45' BENDS SHALL NOT BE
THAN 45- BEND) EVERY 2ND CHANGE 4" CLEANOUT WYE WITH
ACCEPTABLE (SEE NOTE 11)
IN DIRECTION OR GRADE WILL REQUIRE 45 BEND AND PLUG
A CLEANOUT WYE (SEE NOTE 11) I (SEE NOTE 11)
I
z
z
HOUSE
gI
rc
a
HOUSE
oI
0
a
HOUSE
gI
o
a
HOUSE
3
-0" MIN
ISURFACE
4" SEWER PIPE
CLEANOUT
4" SURFACE : v
(TYPICAL)
6"z 6"z6" WYE
a - CLEANOUT
4" SEWER PIPE, SEE NOTES 2
(SEE STD PLAN - 407)
WYE
�4"
4" TEST TEE WITH _
AND 3 MINIMUM LINE SIZE FOR
1
WYE WITH
PLUG FACE UP
OTHER THAN SINGLE FAMILY IS 6"
11 R O W LINE
CLX LIT
(TYPICAL) — I
R 0 W LINE
—
3' MIN
6"z 4" REDUCER v
F F
?
(TYPICAL) z
MAIN SEWER LINE
NOTES
_z IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING
X
< FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION
1 PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, A
o OF THE NEXT UPSTREAM MANHOLE COVER OF THE
SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF
PUBLIC SEWER SYSTEM, A BACKFLOW PREVENTION
RENTON PUBLIC WORKS DEPARTMENT.
b
? DEVICE SUCH AS CLEAN CHECK EXTENDABLE
yr
BACKWATER VALVE OR APPROVED EQUAL SHALL BE
INSTALLED
2 FOR INSPECTION OF SIDE SEWER, CALL 24 HOURS IN ADVANCE
m
THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER PERMIT
4" FLEXIBLE COUPLING (FERNCO OR EQUAL)
SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE
ON SITE WHEN INSPECTOR ARRIVES AT APPOINTED TIME DO NOT
C
BACKR L THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
N SURFACE CLEANOUT
m
4"x 4"z4" WYE
3 SIDE SEWER PIPE AND FITTINGS SHALL BE PVC SDR 35 WITH RUBBER
4" PIPING
GASKET JOINTS UNLESS OTHERWISE APPROVED BY THE PUBLIC
PLAN
WORKS DEPARTMENT
BUILDING DRAIN FOR
4 A MINIMUM GRADE OF 2% (1/4" PER FOOT) MUST BE MAINTAINED
LOW ELEVATION HOUSE
WITH A 4" PIPE IN THE EVENT A 2% GRADE CANNOT BE MAINTAINED
WITH THE APPROVAL OF THE PUBLIC WORKS INSPECTOR, THE
MAIN TO
CONTRACTOR MAY INSTALL A 6" DIAMETER SIDE SEWER AT NO LESS
5 FEET
R 0 W LINE R 0 W. LINE TO CLEANOUT I MAX
THAN IX
SIDE SEWER
STUB
BUILDING SEWER
BUILDING
DRAIN
5 INSTALL SIDE SEWER WITH 2' MINIMUM COVER 18" COVER IS ALLOWED
3 FEET MIN I--
AT THE HOUSE IF OUTLET IS SHALLOW
6 ALL BUILDING SEWER AND SIDE SEWERS SHALL HAVE BEDDING IN
1 I
\Iq. 1
ACCORDANCE WITH STANDARD PLAN 405
P r = ': min - =
c : -
7 WHENEVER FEASIBLE, THERE SHALL BE A MINIMUM 5 FOOT
n
O W I^ o v_ s 00 ? v n +• v F x > z m g
HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND ALL
a v m p m
m m
OTHER UTILITIES
s m m A z?
°f y v o I^ m i c1 m z m m
8 SIDE SEWER TESTING SHALL CONSIST OF PLACING A PLUG IN THE
? A i• z o A v y o g
TEST TEE AND INSTALLING A 4-FOOT RISER PIPE ON THE CLEANOUT
m o ; = y > C
AT THE BUILDING. THE SIDE SEWER PIPE SHALL BE FILLED TO WITH
s z nm �-
WATER TO THE TOP OF THE RISER PIPE NO LOSS OF WATER SHALL
m 0
OCCUR FOR A PERIOD OF 10 MINUTES. THE SIDE SEWER MAY BE
... z
CONNECTED TO THE BUILDING FOLLOWNG THE SUCCESSFUL
S rn q
COMPLETION OF THE LEAK TEST
" ^=
9 THE CLEANOUT AT THE RIGHT-OF-WAY SHALL BE INSTALLED PER
m PLAN
STANDARD PLAN 406 1 THE CLEANOUT AT THE BUILDING SHALL BE
BUILDING SEWER
INSTALLED TO SURFACE GRADE ALL OTHER CLEANOUTS SHALL BE
INSTALLATION
INSTALLED TO WTHIN 12" OF THE SURFACE
10 IF SIDE SEWER STUB IS NOT AVAILABLE THE OWNER SHALL BE
RESPONSIBLE FOR ITS INSTALLATION PER STANDARD PLAN 4061
ALL WORK WITHIN STREET RIGHT-OF-WAY SHALL BE DONE BY A
LICENSED AND BONDED CONTRACTOR
CALL 811 BEFORE YOU DIG
11 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC
Or g0 to
RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
www callbeforeyoud,g org
12 ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE
WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT (WISHA)
TYPICAL BUILDING SEWER
STD. PLAN - 406.2
PUBLIC WORKS
^"6j
DEPARTMENT
FROM PROPERTY LINE TO
artinPastucli§/26/2oz
5868"IFD98B449D
BUILDING CONNECTION
,w DATE
w
■EI
12
A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
RECESSED
LIFT POCKET
O 3/4" LETTERING "SEWER"
e SEWER a (2) BOLT SOC. (ALLEN HEAD) -
5/8" - 11 X 1 5 STAINLESS
STEEL
REF PART #00981177
O � O 1-3/16" -
SEE 1
10-1/2"
5/1
1/4"12-1/2"�
�I ' 1
-T1-1/g„
2-1/4"
f 213/4 �I
CAST IRON RING AND COVER
Not to Scale
FRAME
1'-Tt" nl nurTro 1'-n"
45- (1/8) BEND
OR
DABLE
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTES.
1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC
No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY
2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER
3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106
STD. PLAN - 403.1
PUBLIC WORKS 8" OR 6" CLEANOUT °^° Y
DEPARTMENT FOR SANITARY SEWER MAIN Martin PastuCfJ$/26/2020
�49U DATE
800 TOTAL GALLON OIL/WATER SEPARATOR
CUSTOMER TO SUPPLY PIPES AND TEES.
PIPING SHOWN FOR REFERENCE ONLY.
1'-6"
2'-6"
2"4 VENT DUCT
a<
° a
f 6„
3„ F
7'-6"
4'-6"
a
3
WATER
LEVEL
u
2EA. 8"6 HOLES
L
n �D"
Q
4
m' 9
1'-5^ 5" 2'-6"
5'-2
L� LJ
3" 1' 5"
-6"
I 12 : 1
ENV-2
2EA. 24"0 ACCESS WITH
2EA. 24"0 D&L A-1024
CAST IRON FRAMES AND COVERS
2EA. 2412 GRADE RINGS
OUTLET LOCATED
1/2" PIPE DIAMETER
LOWER THAN INLET
4Y"
2, �,,,
2
8"
8'-7Y„
6'-0"
4'-6"
7„
TOP SLAB WEIGHT: 3,850 LBS. DRAWING MAY NOT CONFORM TO THE
VAULT WEIGHT: 13,160 LBS. MOST CURRENT SPECIFICATION
® OWS-4878 41-011 X 61-61I X 6-0" (I.D.)
Oldcastle Precast FILENAME: ENV-2.DWG ENVIRONMENTAL VAULT
0 Northern California REVISED: MARCH 2O16 OIL WATER SEPARATOR
Madera. Morgan Hill. Pleasanton. Santa Rosa. Stockton. Tulare
Phone: 925-750-6650 Fax 925-750-6660 www.oldcastleprecast.com Copyright © 2016 014Castle Precastjnc.
S500PSCALE:IL-WATER SEP,
N.T.S.
• Call 811
• m two business days
before you dig NO.
REVISION
W (SEE NOTE 7)
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 5) — — — —
FOUNDATION LEVEL
LIMITS OF PIPE ZONE
O.D.
of
PIPE
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS
5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)
OF THE STANDARD SPECIFICATIONS
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED
7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
STD. PLAN - 405
• PUBLIC WORKS PIPE BEDDING APP
DEPARTMENT FOR SANITARY SEWERS Martin PastUCW26/202!
.won �mFry0986449D DATE
L
FAMorganroth
NT PLANNING
[05/09/2023] 0
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE APPR APPROVED:
DCD
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
I 12
DocuSign Envelope ID 34SB681D-914F-4F2D-AB59-7Cl92D3B78A3
r<� r--r----------I
EX. SEWER MAIN
I I I I
I PROPERTY LINE
F�SEWER
I I I z
AS NEEDED) i 3'-0" MIN
I II b I
WER STUB I FUTURE 4" SIDE SEWER
. 2"x 4" STUD MARKING POST PAINTED
I I I 6" CAP JJJ WHITE WITH THE WORD "SEWER" STENCILED
EE X 6" TEE j j j IIN 3" HIGH BLACK LETTERS AND #6 WIRE
SIDEWALK z WRAPPED AROUND THE STUD AND
I I I I I Z EXTENDED TO THE TOP OF THE STUD
COUPLING TYP 1 1 1 I >
( ) L_J_L_________ J <
rr 13
6"XI!I SURFACE CLEANOUT WITH CAST IRON RING AND COVER
10 (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
II APPROVED EQUAL, SPECIFY "SEWER" ON LID),
UT CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
E CONCRETE PAD TO BE 8" IN DEPTH
F T
L___J II
BEND AS �8"
REQUIRED �
EXISTING SANITARY /_�
SEWER MAIN ., nw UIN SLOPE ,
�\ `6" SEWER STUB �6"X6"X6" WYE `FUTURE 6"x 4" REDUCER
\`SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC do C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL)
0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING
"STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F HOPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL
NOTES•
1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 R SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 110 2
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
SIDE SEWER STUB STD. PLAN -406.1
• PUBLIC WORKS INSTALLATION APP
DEPARTMENT Martin PastUCIAW26/202
(SEWER MAIN TO PROPERTY LINE) aeab�m Deavaaeo DATE
1 12:
sitts&hill
D C. O ,
r CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
`
http://www.sittshill.com/
46449 Project No.: 19480 Project Mgr.: DCD
o,2t'P�cis-rE °,two' 4''
SS�oNAL- EtyG ��n" Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
S-422902 R-422920
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 05/08/2023
I�
[WASTEWATER UTILITY
jstowell05/09/2023
VERTICAL: NAVD 1988 •
HORIZONTAL: NAD 1983/1991 C TY OF
DATE.
BROTHERTON BUICK-GMC - RENTON
RENTON
FIELDBOOK:
PAGE:
°
DATUM Planning/Building/Public Works Dept.
DRAWING NO:
WASTEWATER UTILITIES NOTES AND DETAILS C5.2B
(PRIVATE AND PUBLIC) SHEET: nZ OF:—
29
Fds
L
N
T
O
O
O
N
J
LO
O
co
O
N
N
A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON LEGEND
N RIM=22.06 N a _, so; �, e GLIV I UKY LINK WLJ I PROPOSED FEATURES-
N N IE=19.91, 8 D.I. N �02 s so -'� .Q _ W i �s or 2l;AS
SD' a - W _ / GA / P -
s _ w %L`L� o Ps
IE=16.36, 6"PVC W AS HALT s W DOMESTIC WATER SERVICE
8 / E1.1 2 _GAS - HP _
O _ a a _ w ' ' IH S GAS FIRE SPRINKLER SERVICE
NO PARKINS, a so, _ _ F
0 � � 23 a .so. �w - ' _ N Z ��SS - - GAS - OHP- GE „NO PARKING"
a BP �. so a _ w _ a Sow.
� �= ss ! .,' G GAs. a CHAINU FEN_ WATER METER
�- 0 3
"NO PARKING" 5 e so ss �2 -�Q ° 7.5- T
w _ - -° X S STORM VAULT W/OIL WATER SEPARATOR �(% FIRE DEPARTMENT CONNECTION
SS
y .. .
2
22 - - - - - - ss ... a 3 LIDS. UNABLE TO OPEN 2 OUTER LIDS
7
ASPHALT
POINT OF CONNECTION �'P� � � � - FIRE HYDRANT
° 1E� RIM-24 08
BP o ss a I L TOP OF BAFFLE- 21 78
IE:16.15 8' PVC EXIST. ss a a TES = SS SANITARY SEWER PIPE
>P so �, so _ - IE:16.23 6" PVC NEW ss �2� .... a a I ' = 58, 12"PVC W
t TOP OF VERT TEE 21 5
_aE - ti� TOP OF PIPEBOTT. OF R20.9fT. E 12"PVC E, ® SANITARY SEWER MANHOLE WITH ACCESS LOCATION
N _ - - �2 ss �fEt��IE14E I , :. z UNABLE TO MEASURE IE
I ��� �� a / WATER LEVEL=19.98 • SANITARY SEWER CLEANOUT
N 21 LF 6 CPEP @ 1.00% N x 2 - z BOTT. OF STRUCT. =17.53
s ss 3� a a ° TEI. �� tfEl , - // U N GATE VALVE
N �22�2 Q ©.. - ��. C-SSC005, 6 SSCO _ I
' �? 7 6 -° 8 T RIM:21.95 = \SD p 213 / I ► THRUST BLOCK
LO
�,' _ 1EI ° 22 IE:18.52 6" S (IN)
GAs X �� I IE:18.52 6" N (OUT) 7■-�- I 50� TPN 3340402755
�\ / ti AZULq PROPERTIES LLC
rr
(IS - - CIS as (IS
iO - n • � I ! / I GENERAL NOTES
I I
I
)
VACATED R RENTON I
5 g PER CITY OF 4668
�RDINANCE 0j15p313
REC.
NO 1997
2 92
)LE --� IE=17.97, 12"CPP W
10' BAY
= 12.36 �I / DOOR
1111111
FORCEMAIN E Py �p� 2396 2
mo
0
STORM CATCH BASIN
TYPE I
RIM=23.66
IE=19.65, 12 "CPP N
IE=19.76, 12 "CPP E
IE=19.76, 12 "CPP S
IE=20.38, 6"PVC W
STORM CATCH BASINfi
TYPE I
RIM=22.55
IE=20.28, 6"PVC W
IE=20.02, 12"CPP N
X TOP L \ W
L J
JB
12\ F- / X APPROX 5 I
"WATER LINE"
19.26 X TOP WL - W S_J SD RED "HAZARD"
19.33 (
X TOP WL / gh O `0
X tip•
11 W 0
EXISTING AS -BUILT' rn w x 22• !' , 0
w
WATER MAIN, FIELD W ��/ '`
LOCATED 2024-03-11 N 26 /2 X tititi "NO PARKING" Q►
3
9,0 �O O^�Q'
loop
»NO X titia6 p ' 1913
p0
96
A` 4 goo
CO) �4Q
TELEPHONE
RISER
JHY
COMPOSITE UTILITIES PLAN (PRIVATE AND PUBLIC)
SCALE: 1 "=20'
SURVEYED: SCALE:
VERTICAL: NAVD 1988
DESIGNED:
AS NOTED HORIZONTAL: NAD 1983/1991
DKM/RJJ
• Call 811 2 AS -BUILT WATER MAIN ADJUSTMENTS S&H 03.21.24 DCD DRAWN. KLK/DKM
1 RFI 010 FIRE RISER RELOCATION S&H 08.28.23 DCD CHECKED: ONE INCH DATUM
two business days DCD AT FULL SCALE
IF NOT ONE INCH
z before OU dig APPROVED: SCALE ACCORDINGLY
w y 9 N0. REVISION BY DATE APPR
J DCD
CONSTRUCTION
RECORD DRAWING
PROJECT WAS COMPLETED IN SUBSTANTIAL
CONFORMANCE WITH THE APPROVED
PLANS. ELEVATION DEVIATIONS, WHERE
APPLICABLE, ARE DENOTED WITH PLAN
CALLOUT UPDATES, AND A STRIKEOUT
THROUGH THE ORIGINAL ELEVATION.
UTILITY AS -BUILT INFORMATION OBTAINED
BY MCKEE ENTERPRISES AND VERIFIED BY
SITTS & HILL ENGINEERS, INC.
I�
NORTH
HORIZONTAL SCALE: 1"=20'
20 0 20 40
C TY OF
RENTON
Planning/Building/Public Works Dept.
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND
WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C,
RESPECTIVELY.
3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION.
8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK
INSTALLATION.
9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON
FORCES.
KEY NOTES
2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.4C.
2� 6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD.
PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT.
:� 6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN.
:� 2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN.
:� 6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK.
%" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C.
7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD.
PLAN 340.8/C5.3C.
SEE L2.00 FOR IRRIGATION PLAN
OIL WATER SEPARATOR PER DETAIL 500/C5.2C
10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C
11 INSTALL RPBA PER STD PLAN 350.2/C5.4C
12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE
THRUST BLOCK
13 6" D.I. 11.25 DEGREE FITTING WITH THRUST BLOCK.
sitts&hill
4�Ee �C�rf CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
fs PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
�PicGjO .K�` Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
{L'
S-422903 W-422901 I R-422952
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
BROTHERTON CADILLAC - RENTON
COMPOSITE UTILITIES PLAN
(PRIVATE AND PUBLIC)
DATE:
FIELDBOOK:
PAGE:
C4.00
SHEET: OF:
26 39
N
T
O
O
N
Ir
0-
Ln
N
T
O
O
N
a
J
0
O
O
N
A
u
A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
LEGEND
CV
N
CV
I
n
rr
C')
CV
CV
CV
r�1
L; i
Q
Z
8
RIM=22.06
IE=16.44, 6"PVC E
IE=16.36, 6"PVC W
"NO PARKING"
2
O
"NO PARKING"� 5 e
FIN41PA,1I?': 049S
IE=17.97, 12 CPP W
SANITARY POINT F CONNECTION
PER MECHANICA . INVERT ,3 0Q',
BELOW FINISH LOOR, IO
12.36 I
FORCEMAIN L Py ��0� 2396 2
STORM CATCH BASIN
TYPE I
RIM=23.66
IE=19.65, 12 "CPP N
IE=19.76, 12 "CPP E
IE=19.76, 12 "CPP S
IE=20.38, 6"PVC W
STORM CATCH BASINfi
TYPE I
RIM=22.55
IE=20.28, 6"PVC W
IE=20.02, 12"CPP N
i
to wl
HALT
_ w
VHOI F
TELEPHONE
RISER
FIRE DO
NST�I
M OF
VAULT IS
[{IN
SEPARA
EFIRg
ERMIT
G
42"
"WATER LINE"
x 21i RED "HAZARD"
�� I0 � -
G�
�V eG��
--d��w�
�o
ti� �Q•tt,,� � goo
vJ
k
40,, 0
N
7&8" OAS —
1
WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN (PRIVATE)
SCALE: 1 "=20'
• Call 811
• m two business days
before you dig NO.
REVISION
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE AP P R APPROVED:
DCD
s I —
S
oNr- "NO PARKING"
CHAINLINK FENCE
x —STORM VAULT W/OIL WATER SEPARATOR
3 LIDS. UNABLE TO OPEN 2 OUTER LIDS
RIM=24.08
TOP OF BAFFLE=21.78
TOP OF VERT. TEE=21.55,
BOTT. OF VERT. TEE=18.58, 12"PVC W
TOP OF PIPE=20.9f, 12"PVC E,
UNABLE TO MEASURE IE
WATER LEVEL=19.98
BOTT. OF STRUCT.=17.53
I
TPN 3340402755
AZULq PROPERTIES LLC
I I
I
)
VACATED R RENTON I
5 8 PER CITY OF 4668
�RDINANCE 0j150313
REC.
NO 1997
29
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE IN,
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
NORTH
HORIZONTAL SCALE: 1"=20'
20 0 20 40
C TY OF
RENTON
PROPOSED FEATURES-
W
DOMESTIC WATER
SERVICE
F
FIRE SPRINKLER SERVICE
WATER METER
FIRE DEPARTMENT
CONNECTION
W
FIRE HYDRANT
SS
SANITARY SEWER
PIPE
®
SANITARY SEWER
MANHOLE WITH ACCESS LOCATION
•
SANITARY SEWER
CLEANOUT
N
GATE VALVE
►
THRUST BLOCK
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND
WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C,
RESPECTIVELY.
3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION.
8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK
INSTALLATION.
9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON
FORCES.
KEY NOTES
2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.3C.
:� 6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD.
PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT.
B� 6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN.
4� 2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN.
5� 6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK.
%" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C.
7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD.
PLAN 340.8/C5.3C.
SEE L2.00 FOR IRRIGATION PLAN
OIL WATER SEPARATOR PER DETAIL 500/C5.2C
10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C
11 INSTALL RPBA PER STD PLAN 350.2/C5.4C
12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE
THRUST BLOCK
C.
O� pF WA,1 f
r
-r
46449
�O�c C1
'IV
�ss10,vA,
�M.
6,u9ij sitts&hill
CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
S-422904 I W-422902
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING A018t&�'
IL
NJanders 05/08/2023 %jl
WASTEWATER UTILITY
jstowell 05/09/2023
BROTHERTON CADILLAC - RENTON
Plan ning/Building/Public Works Dept. WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN
(PRIVATE)
DATE:
FIELDBOOK:
PAGE:
C5.0C
SHEET: OF:
27 39
N
T
O
O
I
N
,i1
Ln
CV
T
O
O
N
Q
J
LO
O
O
N
CV
A
u
A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
LEGEND
r11-
N
n
i
i
LJ
Q
Z
J
EN
�s�9
4x titi�2 C,-
N
)LE
IL=I/.9/, IL Ut'F' w
12.36
FORCEMAIN E
mo
0
STORM CATCH BASIN
TYPE I
RIM=23.66
IE=19.65, 12"CPP N
IE=19.76, 12 "CPP E
IE=19.76, 12 "CPP S
IE=20.38, 6"PVC W
STORM CATCH BASINfi
TYPE I
RIM=22.55
IE=20.28, 6"PVC W
IE=20.02, 12"CPP N
i
ii
HAL T
VHnI F
TELEPHONE —
RISER
— -
a
0
1
RIM=22.06
IE=16.44, 6"PVC E
IE=16.36, 6"PVC W
"NO PARKING"
0 y
N
i 7&18» OAK
i
ell
. 4241
"WATER LINE"
SID RED "HAZARD"
_.J t N 0-
x 11LNO
PARKING
Z
WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN (PUBLIC)
SCALE: 1"=20'
• Call 811
two business days
before you dig NO.
REVISION
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE APPR �APPROVE DC
D
"NO PARKING"
CHAINLINK FENCE
x 2�STORM VAULT W/OIL WATER SEPARATOR
3 LIDS. UNABLE TO OPEN 2 OUTER LIDS
RIM=24.08
TOP OF BAFFLE=21.78
TOP OF VERT. TEE=21.55,
BOTTT, OF VERT. TEE=18.58, 12"PVC W
TOP OF PIPE=20.9f, 12"PVC E,
UNABLE TO MEASURE IE
WATER LEVEL=19.98
BOTTT, OF STRUCT.=17.53
TPN 3340402755 i
AZULEj PROPERTIES LLC
----VA �F -0 W. N
5 8 PEORCITANITYCE #
RCC NO. 199707150313
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
NORTH
HORIZONTAL SCALE: 1"=20'
20 0 20 40
CITY OF
RENTON
PROPOSED FEATURES-
Wy
DOMESTIC WATER
SERVICE
F
FIRE SPRINKLER SERVICE
WATER METER
FIRE DEPARTMENT
CONNECTION
Y
FIRE HYDRANT
SS
SANITARY SEWER
PIPE
®
SANITARY SEWER
MANHOLE WITH ACCESS LOCATION
•
SANITARY SEWER
CLEANOUT
N
GATE VALVE
►
THRUST BLOCK
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND
WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C,
RESPECTIVELY.
3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION.
8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK
INSTALLATION.
9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON
FORCES.
KEY NOTES
2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.3C.
2� 6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD.
PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT.
3� 6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN.
4� 2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN.
:� 6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK.
3/" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C.
7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD.
PLAN 340.8/C5.3C.
SEE L2.00 FOR IRRIGATION PLAN
OIL WATER SEPARATOR PER DETAIL 500/C5.2C
10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C
11 INSTALL RPBA PER STD PLAN 350.2/C5.4C
12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE
THRUST BLOCK
sitts&hill
6u9
CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
W-422905
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING A018t&�'
IL
Wanders 05/08/2023 %,�#1
BROTHERTON CADILLAC - RENTON
Planning/Building/Public works Dept. WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN
(PUBLIC)
DATE:
FIELDBOOK:
PAGE:
DRAWING NO:
C5.1C
SHEET: OF:
28 39
Nt
N
T
O
O
I
N
N
It
'11
Lid
N
T
O
O
N
Q
ZD
J
LO
O
It
O
N
N
Alu
N
N
I
N
DocuSign Envelope ID 345B681D-914E-4F2D-AB59-7C192D3B78A3
WASTEWATER UTILITY STANDARD NOTES
1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY
OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND
SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS 8 SPECIFICATIONS
A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION
2 DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 HORIZONTAL CONTROL
SHALL BE NORTH AMERICAN DATUM 1983/1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS
AND MONUMENTS SHALL BE REFERENCED ON THE APPROVED PLANS
3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS,
INCLUDING STREET USE PERMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED
BY A REPRESENTATIVE OF THE CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC
WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION
4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC
CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY
5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND
FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL,
STATE AND FEDERAL REQUIREMENTS.
6. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE
THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE
OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR
SHALL HAVE A COPY OF THE DIG TICKET ON SITE AT ALL TIMES
7. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH
OF 12-INCHES, MAXIMUM DEPTH 18-INCHES, THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF
MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE
EQUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19).
8 SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034, SDR 35,
C900/C905 OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE CITY
9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC)
UNLESS APPROVED BY THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL,
BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE
OF WASHINGTON IN ACCORDANCE WITH STANDARD DETAIL 412
10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE
BACKFILLED WITH CRUSHED SURFACING AGGREGATE (WSDOT SPECIFICATION 9-03 9(3) AND MECHANICALLY
COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY
11 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH
THE STANDARDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS
AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANDARD PLANS 8
SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED
ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEDDING SHALL BE IN ACCORDANCE WITH STANDARD PLAN
405
12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF
THE CITY FOR THE PREVENTION OF ON -SITE EROSION BOTH DURING CONSTRUCTION AND AFTER THE
COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL
13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER
SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED
PROFESSIONAL SURVEYOR
ST . PLAN - 413
PUBLIC WORKS WASTEWATER UTILITY APPROVED
DEPARTMENT STANDARD NOTES Martin Pastucha<D/zb/z
DATE
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
ALL 90 TURNS SHALL BE ACCOMPLISHED
4" BEND AS REWIRED (NO GREATER
BY MEANS OF A WYE WITH CLEANOUT AND
45 BEND TWO 45' BENDS SHALL NOT BE
THAN 45' BEND) EVERY ZNO CHANGE 4" CLEANOUT WYE WITH
ACCEPTABLE (SEE NOTE 11)
IN DIRECTION OR GRADE WILL REQUIRE 45 BEND AND PLUG
A CLEANOUT WYE (SEE NOTE 11) I (SEE NOTE 11)
z
z
z
HOUSE
gI
a
HOUSE
oI
a
HOUSE
gI
a
HOUSE
3
-0" MIN
I:
4" SEWER PIPE
SURFACE CLEANOUT
4" SURFACE v
(TYPICAL)
6"z 6"z6" WYE
a CLEANOUT
4" SEWER PIPE, SEE NOTES 2
(SEE STD PLAN - 407)
WYE
�4"
4" TEST TEE WITH _
AND 3 MINIMUM LINE SIZE FOR
1
WYE WITH
PLUG FACE UP
OTHER THAN SINGLE FAMILY IS 6"
R O W LINE
CLEANOUT
(TYPICAL) - I
ROW LINE
-
3' MIN
6"x 4" REDUCER e
v
F F
?
(TYPICAL) z
MAIN SEWER LINEX
Xi
NOTES
_z IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING
X
` FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION
1 PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, A
o OF THE NEXT UPSTREAM MANHOLE COVER OF THE
SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF
PUBLIC SEWER SYSTEM, A BACKFLOW PREVENTION
RENTON PUBLIC WORKS DEPARTMENT.
b
? DEVICE SUCH AS CLEAN CHECK EXTENDABLE
vI
BACKWATER VALVE OR APPROVED EQUAL SHALL BE
INSTALLED
2 FOR INSPECTION OF SIDE SEWER, CALL 24 HOURS IN ADVANCE
m
THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER PERMIT
4" FLEXIBLE COUPLING (FERNCO OR EQUAL)
SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE
ON SITE WHEN INSPECTOR ARRIVES AT APPOINTED TIME DO NOT
C
BACKR L THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
N SURFACE CLEANOUT
m
4"x 4"z4" WYE
3 SIDE SEWER PIPE AND FITTINGS SHALL BE PVC SDR 35 WITH RUBBER
4" PIPING
GASKET JOINTS UNLESS OTHERWISE APPROVED BY THE PUBLIC
PLAN
WORKS DEPARTMENT
BUILDING DRAIN FOR
4 A MINIMUM GRADE OF 2% (1/4" PER FOOT) MUST BE MAINTAINED
LOW ELEVATION HOUSE
WITH A 4" PIPE IN THE EVENT A 2% GRADE CANNOT BE MAINTAINED
WITH THE APPROVAL OF THE PUBLIC WORKS INSPECTOR, THE
MAIN TO
CONTRACTOR MAY INSTALL A 6" DIAMETER SIDE SEWER AT NO LESS
5 FEET
R 0 W LINE R 0 W. LINE TO CLEANOUT I MAX
THAN IX
SIDE SEWER
STUB
BUILDING SEWER
BUILDING
DRAIN
5 INSTALL SIDE SEWER WITH 2' MINIMUM COVER 18" COVER IS ALLOWED
3 FEET MIN I--
AT THE HOUSE IF OUTLET IS SHALLOW
6 ALL BUILDING SEWER AND SIDE SEWERS SHALL HAVE BEDDING IN
1
ACCORDANCE WITH STANDARD PLAN 405
m m < c .: . a = ':
i n =
7 WHENEVER FEASIBLE, THERE SHALL BE A MINIMUM 5 FOOT
rnAi
O W I^ o v_ s 00 ? v n +• v F x > z m g
HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND ALL
a O m m v m p m
OTHER UTILITIES
a b m A z?
°f y o I^ m i cI m m
8 SIDE SEWER TESTING SHALL CONSIST OF PLACING A PLUG IN THE
z A i• i o A v y T g 0
TEST TEE AND INSTALLING A 4-FOOT RISER PIPE ON THE CLEANOUT
o
m o ; = y
AT THE BUILDING. THE SIDE SEWER PIPE SHALL BE FILLED TO WITH
s z n
WATER TO THE TOP OF THE RISER PIPE NO LOSS OF WATER SHALL
m m inn r^ 0
OCCUR FOR A PERIOD OF 10 MINUTES. THE SIDE SEWER MAY BE
... z
CONNECTED TO THE BUILDING FOLLOWING THE SUCCESSFUL
S rn q
COMPLETION OF THE LEAK TEST
" c=
9 THE CLEANOUT AT THE RIGHT-OF-WAY SHALL BE INSTALLED PER
m PLAN
STANDARD PLAN 406 1 THE CLEANOUT AT THE BUILDING SHALL BE
BUILDING SEWER
INSTALLED TO SURFACE GRADE ALL OTHER CLEANOUTS SHALL BE
INSTALLATION
INSTALLED TO WITHIN 12" OF THE SURFACE
10 IF SIDE SEWER STUB IS NOT AVAILABLE THE OWNER SHALL BE
RESPONSIBLE FOR ITS INSTALLATION PER STANDARD PLAN 4061
ALL WORK WITHIN STREET RIGHT-OF-WAY SHALL BE DONE BY A
LICENSED AND BONDED CONTRACTOR
CALL 811 BEFORE YOU DIG
11 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC
Or g0 to
RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
www callbeforeyoud,g org
12 ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE
WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT (WISHA)
TYPICAL BUILDING SEWER
STD. PLAN - 406.2
PUBLIC WORKS
ro..ed6r
URI DEPARTMENT
FROM PROPERTY LINE TO
artinPastucli§/26/2oz
511168"11,,,.IB441D
BUILDING CONNECTION
DATE
■EI
1 12
A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
RECESSED
LIFT POCKET
O 3/4" LETTERING "SEWER"
e SEWER a (2) BOLT SOC. (ALLEN HEAD) -
5/8" - 11 X 1 5 STAINLESS
STEEL
REF PART //00981177
-
1-3/16"
SEE I
10-1/2"
5/1
1/4"12-1/2"F 1"'
-T1-1/g„
2-1/4"
f 213/4 �I
CAST IRON RING AND COVER
Not to Scale
FRAME
1'-(1" nlnurTro 1'-rl"
_- 45- (1/8) BEND
OR
DABLE
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTES.
1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC
No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY
2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER
3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106
STD. PLAN - 403.1
PUBLIC WORKS 8" OR 6" CLEANOUT xrOuRogned by
DEPARTMENT FOR SANITARY SEWER MAIN Martin PastuCfJ$/26/2020
G) � h49D DATE
800 TOTAL GALLON OIL/WATER SEPARATOR
CUSTOMER TO SUPPLY PIPES AND TEES.
PIPING SHOWN FOR REFERENCE ONLY.
V-6"
5'-0"
2'-6"
2"4 VENT DUCT
a<
° a
f 6„
1, 13„ � a
7'-6"
4'-6"
a
3
WATER
LEVEL
2EA. 8"6 HOLES m
L
a
4
m' 9
1'-5" 5" 2'-6"
5'-2
-6"
1 12 : 1
ENV-2
2EA. 24"0 ACCESS WITH
2EA. 24"0 D&L A-1024
CAST IRON FRAMES AND COVERS
2EA. 2412 GRADE RINGS
OUTLET LOCATED
1/2" PIPE DIAMETER
LOWER THAN INLET
4Y"
f
8"
8'-7Y„
6'-0"
4'-6"
7„
TOP SLAB WEIGHT: 3,850 LBS. DRAWING MAY NOT CONFORM TO THE
VAULT WEIGHT: 13,160 LBS. MOST CURRENT SPECIFICATION
0
® OWS-4878 41-011 X 61-61I X 6-0" (I.D.)
Oldcastle Precast FILENAME: ENV-2.DWG ENVIRONMENTAL VAULT
Northern California REVISED: MARCH 2O16 OIL WATER SEPARATOR
Madera. Morgan Hill. Pleasanton. Santa Rosa. Stockton -Tulare
Phone: 925-750-6650 Fax:925-750-6660 www.oldcastleprecast.com Copyright © 2016 Oldeastle Precest,lnc.
SOIL —WATER SEP,
SCALE: N.T.S.
• Call 811
• m two business days
before you dig NO.
REVISION
W (SEE NOTE 7)
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 5) ----\
FOUNDATION LEVEL
-- LIMITS OF PIPE ZONE
O.D.
of
PIPE
51
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS
5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)
OF THE STANDARD SPECIFICATIONS
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED
7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
STD. PLAN - 40S
• PUBLIC WORKS PIPE BEDDING APP
DEPARTMENT FOR SANITARY SEWERS Martin PastUCW26/202!
.won �mFry0980449D DATE
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE APPR APPROVED:
DCD
1 12
DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
r<� r--I-r----------
I— EX. SEWER MAIN
I I I I
l PROPERTY LINE
F�SEWWER
z
AS NEEDED) 3'-0" MIN
O
WER STUBFUTURE 4" SIDE SEWER
2"x 4" STUD MARKING POST PAINTED
6" CAPWHITE WITH THE WORD "SEWER" STENCILED
EE X 6" TEE i i i I IN 3" HIGH BLACK LETTERS AND #6 WIRE
SIDEWALK z WRAPPED AROUND THE STUD AND
I I I I I EXTENDED TO THE TOP OF THE STUD
COUPLING TYP I I I I >
rr� 13
6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
(EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
APPROVED EQUAL, SPECIFY "SEWER" ON LID),
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
CONCRETE PAD TO BE 8" IN DEPTH
17-
BEND AS �� T8"
REQUIRED
EXISTING SANITARY /_�
SEWER MAIN ., nw MIN SLOPE ,
_1"\ `6" SEWER STUB � 5"X6"X6" WYE `FUTURE 6"x 4" REDUCER
\`SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN
A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC do C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL)
0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING
"STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
F HOPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL
NOTES•
1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 R SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
SIDE SEWER STUB STD. PLAN -406.1
• PUBLIC WORKS INSTALLATION APP
DEPARTMENT Martin PastUCKW26/202
(SEWER MAIN TO PROPERTY LINE) aeab�m Deav4490 DATE
1 12:
1,D C. sitts&hill
O� of w'9�
44 C rJ1 laU09AJ
CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
V PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
Project No.: 19480 Project Mgr.: DCD
05 46449 4
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
SIpNpL ��
oM S-422906
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
NJanders 05/08/2023
WASTEWATER UTILITY
jstowell 05/09/2023
01
SCALE: DATE:
VERTICAL: NAVD 1988• BROTHERTON CADILLAC - RENTON
AS NOTED HORIZONTAL: NAD 1983/13/1991 C T Y OF
FIELDBOOK:
RENTON PAGE:
° ONE INCH DATUM DRAWING NO:
AT FULL SCALE Plan ning/Building/Public Works Dept. WASTEWATER AND WATER UTILITIES NOTES C5.210
IF NOT ONE INCH
SCALE ACCORDINGLY (PRIVATE AND PUBLIC)
SHEET: OF: