HomeMy WebLinkAboutW-422902A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
m
N
N
RIM=22.06
I
IE=16.44, 6"PVC E
IE=16.36, 6"PVC W
(�J
"NO PARKING"
r
POINT OF CONNECTION-5? M
"NO PARKING"
IE:16.15 8" PVC EXIST.
IE:16.23 6" PVC NEW SD
(PRIVATE SYSTEM UPSTREAM_a-
eP OF CONNECTION AT MAIN)
�D
uv
101, ��`SD�' / - SS
SS
2LF-6"O 6" PVC SDR35 @ 102.50% 4�
N
-1
- - 12?� j� - 21LF 6" O 6" DIP CL52 @ 1.00%�
N
N
N - SS �5y
10
X22 6 8
/�
L.L
1 � TEI
X /C
� ° i \
GPS
pO
T&Lp
4 PS i 2� 7 - Q�i S _
A
OWS POINT Or TCONNECTION PER
MECHANICAL. I0'I�33�' QELOW
FINIM-1gA,'ItJYOW
IE=17.97, 12"CPP W
SANITARY POINT F CONNECTION
PER MECHANICA . INVERT 3.00'
BELOW FINISH LOOR, Iq e�6
= 12.36 1
FORCEMAIN L Py ��0� 2396 2
mo
0
STORM CATCH BASIN
TYPE I
RIM=23.66
IE=19.65, 12 "CPP N
IE=19.76, 12 "CPP E
IE=19.76, 12 "CPP S
IE=20.38, 6"PVC W
STORM CATCH BASINfi
TYPE I
RIM=22.55
IE=20.28, 6"PVC W
IE=20.02, 12"CPP N
i
EXISTING AS -BUILT'
WATER MAIN, FIELD -
LOCATED 2024-03-11
loop ' `L ivv X titiab
P
titi1$ 23
TELEPHONE
RISER
JH(
L;j
Q
z
J
�0„ 0
N
7&8" OAS -
1
42"
"WATER LINE"
ailljlllllll RED "HAZARD"
XO(0` ` •
0 �, O •
"NO PARKING" ` r^
A,�Q��°o
C
WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN (PRIVATE)
SCALE: 1 "=20'
3 AS -BUILT WATER MAIN ADJUSTMENTS S&H
• Call 811 2 FIELD CONDITIONS CONFLICT RESOLUTION S&H
• ° two business days 1 RFI 010 FIRE RISER RELOCATION S&H
before you dig NO. REVISION BY
SURVEYED:
DESIGNED:
03.21.24 DCD DKM/RJJ
11.02.23 DCD DRAWN:
KLK/DKM
08.28.23 DCD CHECKED:
DCD
DATE AP P R APPROVED:
DCD
EN I UKY LINK WLJ I '
2.S
GAS
oNY- "NO PARKING"
CHAINLINK FENCE
X �k' STORM VAULT W/OIL WATER SEPARATOR
3 LIDS. UNABLE TO OPEN 2 OUTER LIDS
RIM=24.08
TOP OF BAFFLE=21.78
TOP OF VERT. TEE=21.55,
BOTT. OF VERT. TEE=18.58, 12"PVC W
TOP OF PIPE=20.9f, 12"PVC E,
UNABLE TO MEASURE IE
WATER LEVEL=19.98
BOTT. OF STRUCT.=17.53
1
TPN 3340402755 1
AZULq PROPERTIES LLC
I 1
I
)
VACATED R RENTON I
5 g PER CITY OF 4668
�RDINANCE 0j15p313
REC.
NO 1997
2 92
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CONSTRUCTION
RECORD DRAWING
PROJECT WAS COMPLETED IN SUBSTANTIAL
CONFORMANCE WITH THE APPROVED
PLANS. ELEVATION DEVIATIONS, WHERE
APPLICABLE, ARE DENOTED WITH PLAN
CALLOUT UPDATES, AND A STRIKEOUT
THROUGH THE ORIGINAL ELEVATION.
UTILITY AS -BUILT INFORMATION OBTAINED
BY MCKEE ENTERPRISES AND VERIFIED BY
SITTS & HILL ENGINEERS, INC.
NORTH
HORIZONTAL SCALE: 1"=20'
20 0 20 40
C TY OF
RENTON
LEGEND
PROPOSED FEATURES-
Wy
DOMESTIC WATER
SERVICE
F
FIRE SPRINKLER SERVICE
m
WATER METER
FIRE DEPARTMENT
CONNECTION
Y
FIRE HYDRANT
SS
SANITARY SEWER
PIPE
®
SANITARY SEWER
MANHOLE WITH ACCESS LOCATION
•
SANITARY SEWER
CLEANOUT
N
GATE VALVE
►
THRUST BLOCK
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND
WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C,
RESPECTIVELY.
3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION.
8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK
INSTALLATION.
9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON
FORCES.
10. SEE SANITARY SEWER PROFILE ON C5.2C.
KEY NOTES
2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.4C.
:� 6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD.
PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT.
6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN.
2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN.
6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK.
3/" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C.
7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD.
PLAN 340.8/C5.3C.
8� SEE L2.00 FOR IRRIGATION PLAN
OIL WATER SEPARATOR PER DETAIL 500/C5.2C
10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C
11 INSTALL RPBA PER STD PLAN 350.2/C5.4C
12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE
THRUST BLOCK
13 6" D.I. 11.25 DEGREE FITTING WITH THRUST BLOCK.
sitts&hill
CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
S-422904 I W-422902
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
BROTHERTON CADILLAC - RENTON
Planning/Building/Public Works Dept. WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN
(PRIVATE)
DATE:
FIELDBOOK:
PAGE:
C5.00
SHEET: OF:
27 39
N
T
O
O
N
Ir
0-
LO
T
O
O
I
N
N
a
J
LO
O
O
O
N
A
u