HomeMy WebLinkAboutW-422903A PORTION OF THE NW 1/4 OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., KING COUNTY, WASHINGTON
LEGEND
r11-
N
n
i
i
LJ
Q
Z
J
EN
�s�9
4x titi�2 C,-
N
)LE
IL=I/.9/, IL Ut'F' w
12.36
FORCEMAIN E
mo
0
STORM CATCH BASIN
TYPE I
RIM=23.66
IE=19.65, 12"CPP N
IE=19.76, 12 "CPP E
IE=19.76, 12 "CPP S
IE=20.38, 6"PVC W
STORM CATCH BASINfi
TYPE I
RIM=22.55
IE=20.28, 6"PVC W
IE=20.02, 12"CPP N
i
ii
HAL T
VHnI F
TELEPHONE —
RISER
— -
a
0
1
RIM=22.06
IE=16.44, 6"PVC E
IE=16.36, 6"PVC W
"NO PARKING"
0 y
N
i 7&18» OAK
i
ell
. 4241
"WATER LINE"
SID RED "HAZARD"
_.J t N 0-
x 11LNO
PARKING
Z
WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN (PUBLIC)
SCALE: 1"=20'
• Call 811
two business days
before you dig NO.
REVISION
SURVEYED:
DESIGNED:
DKM/RJJ
DRAWN:
KLK/DKM
CHECKED:
DCD
BY DATE APPR �APPROVE DC
D
"NO PARKING"
CHAINLINK FENCE
x 2�STORM VAULT W/OIL WATER SEPARATOR
3 LIDS. UNABLE TO OPEN 2 OUTER LIDS
RIM=24.08
TOP OF BAFFLE=21.78
TOP OF VERT. TEE=21.55,
BOTTT, OF VERT. TEE=18.58, 12"PVC W
TOP OF PIPE=20.9f, 12"PVC E,
UNABLE TO MEASURE IE
WATER LEVEL=19.98
BOTTT, OF STRUCT.=17.53
TPN 3340402755 i
AZULEj PROPERTIES LLC
----VA �F -0 W. N
5 8 PEORCITANITYCE #
RCC NO. 199707150313
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
NORTH
HORIZONTAL SCALE: 1"=20'
20 0 20 40
CITY OF
RENTON
PROPOSED FEATURES-
Wy
DOMESTIC WATER
SERVICE
F
FIRE SPRINKLER SERVICE
WATER METER
FIRE DEPARTMENT
CONNECTION
Y
FIRE HYDRANT
SS
SANITARY SEWER
PIPE
®
SANITARY SEWER
MANHOLE WITH ACCESS LOCATION
•
SANITARY SEWER
CLEANOUT
N
GATE VALVE
►
THRUST BLOCK
GENERAL NOTES
1. SEE APPLICABLE GENERAL CIVIL NOTES ON SHEETS C5.2C AND C5.3C.
2. SEE CITY OF RENTON STANDARD WASTEWATER (STD. PLAN C413) AND
WATER (STD. PLAN 300.0) NOTES ON SHEETS C5.2C AND C5.3C,
RESPECTIVELY.
3. SEE STD. PLAN 403.1/C5.2C FOR SANITARY SEWER CLEANOUT INSTALLATION.
4. SEE STD. PLAN 405/C5.2C FOR SANITARY SEWER PIPE INSTALLATION.
5. SEE STD. PLAN 406.1/C5.2C FOR SANITARY SEWER STUB INSTALLATION
FROM MAIN LINE TO PROPERTY LINE.
6. SEE STD. PLAN 406.2/C5.2C FOR SANITARY SEWER INSTALLATION FROM
PROPERTY LINE TO BUILDING CONNECTION.
7. SEE STD. PLAN 330.1/C5.3C FOR WATER VALVE BOX INSTALLATION.
8. SEE STD PLANS 330.2 AND 330.3 ON C5.3C FOR THRUST BLOCK
INSTALLATION.
9. WATER SERVICE INSTALLATION SHALL BE PERFORMED BY CITY OF RENTON
FORCES.
KEY NOTES
2' DOMESTIC WATER METER & METER BOX PER STD. PLAN 320.3/C5.3C.
2� 6" DDCV ASSMBLY WITH STANDPIPE OUTSIDE CONNECTION PER STD.
PLAN 360.2/C5.3C. NEW METER TO BE INSTALLED WITHIN EASEMENT.
3� 6" D.I. CLASS 52 SERVICE PIPING, LENGTH PER PLAN.
4� 2" TYPE 'K' COPPER SERVICE PIPING, LENGTH PER PLAN.
:� 6" D.I. 90 DEGREE FITTING WITH THRUST BLOCK.
3/" IRRIGATION METER AND METER BOX PER STD PLAN 320.1/C5.3C.
7� 1" DOUBLE CHECK VALVE ASSEMBLY FOR IRRIGATION SYSTEM, SEE STD.
PLAN 340.8/C5.3C.
SEE L2.00 FOR IRRIGATION PLAN
OIL WATER SEPARATOR PER DETAIL 500/C5.2C
10 INSTALL SIDE SEWER STUB PER STD PLAN 406.1 /C5.2C
11 INSTALL RPBA PER STD PLAN 350.2/C5.4C
12 INSTALL 8" x 6" TAPPING TEE (MJxFL), 6" GATE VALVE, AND CONCRETE
THRUST BLOCK
sitts&hill
6u9
CIVIL I STRUCTURAL I SURVEY
4815 CENTER STREET I TACOMA, WA. 98409
PHONE: (253) 474-9449 I FAX: (253) 474-0153
http://www.sittshill.com/
Project No.: 19480 Project Mgr.: DCD
Proj. Engineer: DKM/RJJ Proj. Drafter: KLK/DKM
W-422905
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING A018t&�'
IL
Wanders 05/08/2023 %,�#1
BROTHERTON CADILLAC - RENTON
Planning/Building/Public works Dept. WASTEWATER AND WATER UTILITIES CONSTRUCTION PLAN
(PUBLIC)
DATE:
FIELDBOOK:
PAGE:
DRAWING NO:
C5.1C
SHEET: OF:
28 39
Nt
N
T
O
O
I
N
N
It
'11
Lid
N
T
O
O
N
Q
ZD
J
LO
O
It
O
N
N
Alu