Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2023.0313_8833_Sounders HQ Practice Facility -100%DD_Mechanical Progress Set
M T= B= FSD MOD BDD FD FSD BDD M FD TOP PER FOOT PITCH PITCH PER FOOT IE BOP LC TS TI PI TL DP RS RL NG FOV FOS FOR CHS CHR CD . . EF-X ∅ R R R R - XXX XX'-XX" X X L-*-*SP*-* 1/X" 1/X" XX'-XX" XX'-XX" X-X X XX'-XX" RECT ROUND ROUND ROUND RECT ROUND RECT ROUND ROUND ROUND RECT T MECHANICAL INDEX OF DRAWINGS DRY BULB / DECIBEL AIR CONDITIONING UNIT AIRFLOW MEASURING UNIT ABOVE FINISHED FLOOR BRITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CONDENSER / CONDENSATE CONDENSING UNIT / CUBIC CHILLED WATER PUMP CC COOLING COIL CWP DN DMPR DEG DIA D DB DOWN DAMPER DIAMETER DEGREE DRAIN CT CU CV CP CNTFGL COND CFM CLG CHLR CIRCULATING PUMP COOLING TOWER CONSTANT VOLUME CENTRIFUGAL CHILLER CEILING AC BOD BOT BTUH BDD AMS B AHU AFF BACKDRAFT DAMPER BOTTOM OF DUCT BOTTOM AIR HANDLING UNIT BOILER ABBREVIATIONS RH RELATIVE HUMIDITY UH WG WT VEL WB W UNO VAV VA VD VENT SS TOS TP TSP TYP UBD ST TCV TOD TDH SENS SF SL SP SMACNA SA UNIT HEATER WATER GAUGE WEIGHT WET BULB (TEMPERATURE) INSULATED DUCT / WATT / WIDE VARIABLE AIR VOLUME VENTILATION / VENTILATOR UNLESS NOTED OTHERWISE VELOCITY VOLUME DAMPER VALVE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION STAINLESS STEEL TOTAL STATIC PRESSURE TEMPERATURE CONTROL VALVE TOP OF STEEL UPBLAST DISCHARGE TOTAL PRESSURE TYPICAL SOUND TRAP TOP OF DUCT TOTAL DYNAMIC HEAD SUPPLY FAN / SQUARE FOOT SOUND LINE (INSIDE DUCT INSULATION ) STATIC PRESSURE SENSIBLE SUPPLY AIR MECH REF RA RF REV PL PD PT POC NO NTS OBD OSA OD OC MOD MTD NIC NC LWT LAT LB MBH HX ID IN KW HC HP HT HORIZ HVAC GPM GWB GALV MECHANICAL POINT OF CONNECTION PRESSURE DROP / PUMPED DRAIN RETURN AIR RELIEF FAN REFERENCE REVISION POST-TENSION SLAB PLENUM MOTOR OPERATED DAMPER NORMALLY CLOSED / NOISE CRITERIA NORMALLY OPEN / NUMBER OUTSIDE DIMENSION OR DIAMETER OPPOSED BLADE DAMPER NOT TO SCALE ON CENTER OUTSIDE AIR NOT IN CONTRACT MOUNTED HEATING, VENTILATING, AND AIR CONDITIONING INDIRECT DRAIN / INSIDE DIAMETER LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE THOUSAND BTU PER HOUR POUND HEAT EXCHANGER INCH KILOWATT GALLONS PER MINUTE HEATING COIL HORIZONTAL HORSEPOWER HEAT TRACE GALVANIZED GYPSUM WALLBOARD ABBREVIATIONS FSD FTU FT FV FPM FD FCU FLTR ELEV EWT ESP EXT EXH EAT EF EER EDH ELEC ECONO EA FIRE DAMPER / FLOOR DRAIN FEET PER MINUTE FACE VELOCITY FAN TERMINAL UNIT FIRE SMOKE DAMPER FEET FAN COIL UNIT FILTER ENERGY EFFICIENCY RATIO ELECTRIC DUCT HEATER ENTERING AIR TEMPERATURE EXTERIOR / EXTERNAL ENTERING WATER TEMPERATURE EXTERNAL STATIC PRESSURE ELECTRIC EXHAUST EXHAUST FAN ECONOMIZER ELEVATION EXHAUST AIR PIPING RS RL MAV FOV NG FOS FOR CHS CHR CD AAV SYMBOL ABBR TEMPERATURE PRESSURE TEST PLUG REFRIGERANT SUCTION REFRIGERANT LIQUID METER MANUAL AIR VENT NATURAL GAS FUEL OIL VENT FUEL OIL SUPPLY FUEL OIL RETURN FLEX FLANGE CHILLED WATER SUPPLY CHILLED WATER RETURN COOLING COIL CONDENSATE AUTOMATIC AIR VENT DESCRIPTION GENERAL NOTES W (CONTINUED) REFER TO PLANS FOR METER SERVICE 1.THE MECHANICAL SCOPE OF WORK SHALL INCLUDE WORK INDICATED ON DRAWINGS AND IN SPECIFICATIONS. 2.VERIFY EXISTING CONDITIONS BEFORE COMMENCING WORK ON AN EXISTING MECHANICAL SYSTEM. 3.VERIFY LOCATIONS AND DIMENSIONS OF EQUIPMENT AND COORDINATE WORK PRIOR TO START OF CONSTRUCTION. 4.IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND DRAWINGS CONSULT WITH ENGINEER OF RECORD. 5.COORDINATE MECHANICAL WORK WITH OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WITH THE WORK OF THIS CONTRACTOR. INSTALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE ABOVE. PROVIDE ALL REQUIRED OFFSETS 6.ELEVATIONS ARE REFERENCED FROM FINISHED FLOOR, UNLESS NOTED OTHERWISE. 7.THE MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 8.PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 9.MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING CONSTRUCTION. 10. DUCTWORK SIZES SHOWN ARE INSIDE CLEAR. ADD APPROPRIATE DIMENSION FOR INSULATION OR DUCT LINER TO OBTAIN "TOTAL" DUCT SIZE. 11. PROVIDE CABLE OPERATED DAMPERS FOR VOLUME DAMPERS OVER INACCESSIBLE CEILINGS AND SOFFITS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 12. PROVIDE TRANSITIONS AS REQUIRED TO CONNECT DUCTWORK TO AIR TERMINAL UNITS, FANS, AND OTHER MECHANICAL EQUIPMENT. 13. COORDINATE EXACT LOCATIONS OF ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH ARCHITECT PRIOR TO INSTALLATION. MOUNT WALL THERMOSTATS AT 48" AFF PER MOST RECENT VERSION OF ADA. 14. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING AND IN BRANCHES WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH AND ELSEWHERE AS NOTED ON THE DRAWINGS OR SPECIFICATIONS. 15. PROVIDE 1" THICK DUCT LINER IN RECTANGULAR SUPPLY AIR DUCTWORK WITHIN FIVE FEET DOWNSTREAM OF AIR TERMINAL UNITS UNLESS NOTED OTHERWISE. GENERAL NOTES (CONTINUED) 18. STRUCTURAL CALCULATIONS FOR MECHANICAL EQUIPMENT SHALL BE PROVIDED AS PART OF THE PERMIT SUBMITTAL TO THE CITY. STRUCTURAL CALCULATIONS SHALL BE SIGNED AND SEALED BY A WASHINGTON STATE REGISTERED STRUCTURAL ENGINEER, FOR APPROVAL BY THE AHJ. 19. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO PENETRATION OF ANY STRUCTURAL ELEMENT, IF PENETRATION IS NOT SHOWN ON STRUCTURAL DRAWINGS. 20. PROVIDE SEISMIC RESTRAINTS AND ANCHORAGE PER SMACNA AND THE BUILDING CODE FOR MECHANICAL SYSTEMS, REFERENCE STRUCTURAL. MECHANICAL CONTRACTOR SHALL INDICATE IF A DEFERRED SUBMITTAL FOR PERMITTING IS REQUESTED. 21. GENERAL CONTRACTOR SHALL PROVIDE CUTTING, FRAMING, PATCHING, SEALING AND PAINTING OF WALLS, CEILING AND FLOOR OPENINGS. THIS INCLUDES OPENINGS THOUGH AREA SEPARATION WALLS. 22. PROVIDE A CLEAR ZONE OF 42 INCHES IN FRONT OF THE ELECTRICAL EQUIPMENT. NO MECHANICAL EQUIPMENT FROM FLOOR TO CEILING CAN BE LOCATED IN THIS CLEAR ZONE, OR ABOVE THE EQUIPMENT FOOTPRINT. REFERENCE ELECTRICAL DRAWINGS FOR LOCATIONS. 23. CONTRACTOR SHALL COMPLY WITH TENANT GUIDELINES AND STANDARDS, INCLUDING BUT NOT LIMITED TO: BUILDING MATERIALS, EQUIPMENT AND FIXTURES. 24. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO: EQUIPMENT HOUSEKEEPING PADS, PENETRATION DETAILS, FLASHING AND SEALING DETAILS AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. 25. PROVIDE 30-DEG BOOT OR CONICAL TEE FOR MEDIUM PRESSURE BRANCH DUCT CONNECTIONS. DO NOT USE STRAIGHT TEE FITTINGS UNLESS SPECIFICALLY INDICATED ON DRAWINGS. 26. PROVIDE MANUAL AIR VENTS AT HIGH POINTS IN HYDRONIC PIPING IF EXISTING VENTS DO NOT MEET THIS REQUIREMENT. PROVIDE DRAIN VALVES AT HYDRONIC PIPING LOW POINTS. 27. PROVIDE FLANGES OR UNIONS AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES AND OTHER COMPONENTS TO ALLOW FOR MAINTENANCE 28. PROVIDE DIELECTIC NIPPLES AT CONNECTIONS WITH DISSIMILAR MATERIALS. 29. PROVIDE PRESSURE AND TEMPERATURE TEST PORTS AT SUPPLY AND RETURN PIPING CONNECTIONS TO EQUIPMENT. 30. SIZE BALANCING/ MEASURING VALVES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. DO NOT PROVIDE VALVES LARGER THAN LINE SIZE. 31. MECHANICAL SYSTEMS SHALL BE COMMISSIONED BY A CERTIFIED COMMISSIONING PROFESSIONAL AS REQUIRED BY WSEC SECTION C408. RV REFRIGERANT VENT DUCT LINE EQUIVALENTS LEGEND DOUBLE LINESINGLE LINE DESCRIPTION GENERAL DIFFUSER/GRILLE DESIGNATION TOP OF DUCT, BOTTOM OF DUCT MOTOR OPERATED DAMPER AIR FLOW DIRECTION - AIR FLOW DIRECTION - SUPPLY FIRE DAMPER - PROVIDE ACCESS FIRE/SMOKE DAMPER - PROVIDE ACCESS CONICAL SPIN-IN TAKEOFF ROUND DUCT EQUIPMENT MARK RETURN/EXHAUST GRILLE SUPPLY GRILLE OR DIFFUSER BACKDRAFT DAMPER MANUAL VOLUME DAMPER REMOTE VOLUME DAMPER FLEXIBLE DUCTWORK DUCT END CAP ELEVATION CHANGE RISE (R) OR DROP (D) 45° CONICAL LATERAL 45° LATERAL BOOT TEE BRANCH TAKEOFF, ROUND TEE WITH TURNING VANES TRANSITION (RECTANGULAR TO ROUND) TRANSITION (ROUND TO ROUND/ RECTANGULAR TO RECTANGULAR) BRANCH TEE, RECT BRANCH TAKEOFF, RECT CONICAL TEE SPIN-IN TAKEOFF RETURN OR EXHAUST DESCRIPTIONSYMBOLABBR STR U TOP VALVE IN PIPE RISE OR DROP WYE TYPE STRAINER VERTICAL SLEEVE TOP OF PIPE ELEVATION UNION UP TH SV RV PRV DRAWING NOTE DESIGNATION THERMOMETER TEE DOWN TEE SLEEVE SOLENOID VALVE PRESSURE REDUCING VALVE ROLLING 45 DOWN REDUCING CONCENTRIC REDUCING ECCENTRIC RELIEF VALVE REDUCER POC PG IE GV POINT OF CONNECTION PRESSURE GAUGE INVERT PIPE ELEVATION PLUG PITCH RIGHT PITCH LEFT GLOBE VALVE GAS COCK GATE VALVE FLOW ARROW DN CHK DOWN CIRCUIT SETTER BUTTERFLY VALVE CHECK VALVE BV AD AD BALANCING VALVE AUTOMATIC CONTOL VALVE (3-WAY) AUTOMATIC CONTROL VALVE (2-WAY) BALL VALVE ACCESS DOOR IN CEILING ACCESS DOOR IN WALL 45° DOWN 90° ELBOW 45° ELBOW BFV NEEDLE ISOLATION VALVE WYE TYPE STRAINER WITH VALVE DETAIL/SECTION CALL-OUT AUTOMATIC INTERLOCKED 2-WAY BUTTERFLY VALVE CL-EL CENTERLINE OF PIPE ELEVATION CENTERLINE BREAK CAP BOP BOTTOM OF PIPE ELEVATION DETAIL OR ENLARGED PLAN, NUMBER FOR DETAIL, LETTER FOR ENLARGED PLAN TAG AND HOSE END RADIUS ELBOW, ROUND RADIUS ELBOW, RECT TURNING VANE ELBOW 90° ELBOW UP (SUPPLY) RADIUS ELBOW UP (RETURN/EXHAUST) RADIUS ELBOW UP (SUPPLY) 90° ELBOW DOWN (RETURN/EXHAUST) 90° ELBOW DOWN (SUPPLY) 90° ELBOW UP (RETURN/EXHAUST) ROUND DUCT UP (S/R/E) RADIUS ELBOW DOWN (RETURN/EXHAUST) RADIUS ELBOW DOWN (SUPPLY) ROUND DUCT DOWN (S/R/E) CONTROLS WALL MOUNTED TSTAT WITH CONTROL WIRE TEMPERATURE SENSOR PRESSURE INDICATOR TEMPERATURE INDICATOR LINE VOLTAGE THERMOSTAT SYMBOL DESCRIPTION DUCT PRESSURE SENSOR HWS HWR HEATING WATER SUPPLY HEATING WATER RETURN HWS HWR TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND DUCTWORK. GENERAL CONTRACOR TO PROVIDE TEMPORARY HEATING EQUIPMENT. 16. PROVIDE 1" THICK DUCT LINER IN RECTANGULAR RETURN DUCTWORK OF AIR TERMINAL UNITS, PROVIDE 1" THICK DUCT LINER IN RECTANGULAR TRANSFER AIR DUCTWORK, UNLESS NOTED OTHERWISE. 17. PROVIDE RETURN AIR BOOTS WITH 1" DUCT LINER IN ACOUSTICALLY SENSITIVE AREAS AND WHERE INDICATED ON THE DRAWINGS. © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:13:16 AM3/13/2023 9:13:16 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M001 LEGEND, DRAWING INDEX AND GENERAL NOTES 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SHEET #DESCRIPTION M001 LEGEND, DRAWING INDEX AND GENERAL NOTES M002 MECHANICAL SITE PLAN M003 PERMIT NOTES AND CALCULATIONS M004 PERMIT NOTES AND CALCULATIONS M101 MECHANICAL SCHEDULES M102 MECHANICAL SCHEDULES M103 MECHANICAL SCHEDULES M104 MATERIAL MATRICES MD111 LEVEL 1 - MECHANICAL SOUTH PLAN - DEMO MD112 LEVEL 1 - MECHANICAL NORTH PLAN - DEMO MD113 LEVEL 1 - MECHANICAL EAST PLAN - DEMO MD121 LEVEL 2 - MECHANICAL SOUTH PLAN - DEMO MD122 LEVEL 2 - MECHANICAL NORTH PLAN - DEMO M111 LEVEL 1 - MECHANICAL SOUTH PLAN M112 LEVEL 1 - MECHANICAL NORTH PLAN M113 LEVEL 1 - MECHANICAL EAST PLAN M121 LEVEL 2 - MECHANICAL SOUTH PLAN M122 LEVEL 2 - MECHANICAL NORTH PLAN M133 PENTHOUSE - MECHANICAL EAST PLAN M142 ROOF - MECHANICAL NORTH PLAN MDP111 LEVEL 1 - MECHANICAL PIPING SOUTH PLAN - DEMO MDP112 LEVEL 1 - MECHANICAL PIPING NORTH PLAN - DEMO MDP113 LEVEL 1 - MECHANICAL PIPING EAST PLAN - DEMO MDP121 LEVEL 2 - MECHANICAL PIPING SOUTH PLAN - DEMO MDP122 LEVEL 2 - MECHANICAL PIPING NORTH PLAN - DEMO MP111 LEVEL 1 - MECHANICAL PIPING SOUTH PLAN MP112 LEVEL 1 - MECHANICAL PIPING NORTH PLAN MP113 LEVEL 1 - MECHANICAL PIPING EAST PLAN MP121 LEVEL 2 - MECHANICAL PIPING SOUTH PLAN MP122 LEVEL 2 - MECHANICAL PIPING NORTH PLAN MP133 PENTHOUSE - MECHANICAL PIPING EAST PLAN MP142 ROOF - MECHANICAL PIPING NORTH PLAN MS111 MAINTENANCE SHED MECHANICAL PLANS & ELEVATIONS M301 MECHANICAL PIPING DIAGRAM M401 MECHANICAL DETAILS M402 MECHANICAL DETAILS M403 MECHANICAL DETAILS M501 CONTROL DIAGRAM AND SEQUENCE M502 CONTROL DIAGRAM AND SEQUENCE M503 CONTROL DIAGRAM AND SEQUENCE M601 SECTION, ELEVATION AND ENLARGED PLANS REV DESCRIPTION DATE 50% DD 02/27/2023 CRCR CRCRCRCR CR CR CR CRFEDCBA3456GHJK2.521FEDCBAGHJKL34562.521FEDCBA3456GHJK2.521FEDCBAGHJKL34562.521FEDCBA3456GHJK2.521FEDCBAGHJKL34562.521REMOVE E X IS T ING L A ND S C APEAS RE Q 'D TO PR EP FOR NEWPOOL (ADD AL TERNA T E #1 )REMO V EEXISTINGCON CRET E FEDCBA3456GHJK2.521FEDCBAGHJKL34562.521BOOT WA SHI N G S TAT ION W6W2S3W5W1PLAYER PA T IO173 LAP POO L174 UPFEDCBA3456GHJK2.521FEDCBAGHJKL34562.521W7FEDCBA3456GHJK2.521FEDCBAGHJKL34562.521REMOVE E X IS T ING L A ND S C APEAS RE Q 'D TO PR EP FOR NEWPOOL (ADD AL TERNA T E #1 )REMO V EEXISTINGCON CRET E EXISTING PARKING TO REMAINEXISTING PARKING TO REMAIN OAKESDALE AVE EXISTING PLANTING TO REMAIN, TYP. EXISTING PLANTING AND TREES TO REMAIN, TYP. EXISTING WALKWAY CANOPY TO REMAIN PROPERTY LINE PROPERTY LINE ZONING = CO OVERALL SITE SF = 1,320,419 SF 30.0 AC EXISTING BUILDING = 61,295 SF (5 FLOORS) OVERALL = 306,475 SF ALLOWABLE = UNLIMITED NEW MAINTENANCE BUILDING = 4,000 SF LOT COVERAGE = 5.0% TOTAL FOOTPRINT = 65,295 SF BUILDING HEIGHT = 93'-8" MAINTENANCE = 15'-0" ALLOWABLE = 250' PER CO ZONING PARKING STALLS = 60 PARKING (LEASED SECURE PARKING) PLAYER PARKING AREA = 17,487 SF LEGEND: EXISTING DETENTION POND EXISTING DETENTION POND SETBACK LINE EXISTING WETLAND WETLAND BUFFER SHOWN DASHEDLOT 8 TRACT B LOT 14 TRACT A LOT 12 LOT 13 LOT 21 LOT 11 LOT 22 OVERALL = 5.0% 65,295SF/1,320,419SF LOT COVERAGE BREAKDOWN: TRACT B = 0.0% LOT 11 = 0.0% LOT 12 = 0.0% LOT 13 = 2.2% 4,000SF/183,925SF LOT 14 = 0.0% LOT 21 = 0.0% LOT 22 = 33.5% 61,295SF/183,925SF NOTE: TRASH HANDLING FACILITIES FOR THE OVERALL DEVELOPMENT ARE ADEQUATE TO SUPPORT ALL TRASH, RECYCLING, AND OTHER MATERIAL GENERATED THROUGH THE USE OF THE PLAYING FIELDS100' - 0"150' - 0"150' - 0"EXISTING LONGACRES BUILDING 25-20 NEW MAINTENANCE BUILDING REFER TO CIVIL CONSTRUCTION PERMIT FOR SCOPE OF WORK. RENTON PERMIT # LUA22-000357 EXISTING DETENTION POND NIC NIC © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:13:36 AM3/13/2023 9:13:36 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M002 MECHANICAL SITE PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1" = 60'-0" MECHANICAL SITE PLAN 1 NORTH REV DESCRIPTION DATE HVAC DESIGN CRITERIA BASIS CRITERIA LOCATION RENTON, WA COOLING INDOOR TEMPERATURE CONFERENCE/MEETING 74⁰F ELECTRICAL 78⁰F HYDRO THERAPY 78⁰F IT/AV/IDF/MDF 74⁰F OFFICE 74⁰F LOCKER/TRAINING 74⁰F WEIGHT/WORKOUT 74⁰F HEATING INDOOR TEMPERATURE CONFERENCE/MEETING 70⁰F ELECTRICAL 60⁰F HYDRO THERAPY 78⁰F IT/AV/IDF/MDF 65⁰F VENTILATION PER IMC, 2018 ENVELOPE ROOF "U" VALUE 0.032 BTU/SF-⁰F WALL "U" VALUE 0.099 BTU/SF-⁰F OFFICE 70⁰F LOCKER/TRAINING 70⁰F WEIGHT/WORKOUT 68⁰F COOLING SAFETY FACTOR 10% TOTAL LOAD HEATING SAFETY FACTOR 20% TOTAL LOAD CONFERENCE ROOM 50 W/COMPUTER 150 W/PROJECTOR INTERIOR LIGHTING PER WSEC, 2018 FLOOR "U" VALUE 0.031 BTU/SF-⁰F GLASS "U" VALUE 0.31 BTU/SF-⁰F GLASS SC 0.27 PLUG LOAD OFFICE 150 W/STATION SENSIBLE HEAT PER PERSON 250 BTUH LATENT HEAT PER PERSON 200 BTUH SENSIBLE HEAT PER PERSON (WEIGHT ROOM) 710 BTUH LATENT HEAT PER PERSON (WEGHT ROOM) 1090 BTUH OCCUPANT DENSITY PER WSEC 2018 OCCUPANT DIVERSITY 90% 4. COMMISSIONING PLAN 5. TESTING, ADJUSTING, AND BALANCING REPORT C501.7 EXISTING BUILDING COMMISSIONING EXISTING BUILDING SYSTEMS SHALL BE COMMISSIONED IN ACCORDANCE WITH SECTION C408. C503.4 MECHANICAL SYSTEMS THOSE PARTS OF SYSTEMS WHICH ARE ALTERED OR REPLACED SHALL COMPLY WITH SECTION C.403 C503.4.1 NEW MECHANICAL SYSTEMS ALL NEW MECHANICAL SYSTEMS IN THE EXISTING BUILDING SHALL COMPLY WITH SECTION C403 4. HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION 5. A NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. S.O.O. IS NOT ACCEPTABLE FOR THIS REQUIREMENT. 20 HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2 OF THE WSEC. 21 A REPORT OF TEST PROCEDURES AND RESULTS IDENTIFIED AS "FINAL COMMISSIONING REPORT" SHALL BE DELIVERED TO THE BUILDING OWNER AS REQUIRED BY SECTION C408.1.3 AND SHALL INCLUDE: 1. RESULTS OF FUNCTIONAL PERFORMANCE TESTS. 2. DISPOSITION OF DEFICIENCIES FOUND DURING TESTING, INCLUDING DETAILS OF CORRECTIVE MEASURES USED OR PROPOSED. 3. FUNCTIONAL PERFORMANCE TEST PROCEDURES USED DURING THE COMMISSIONING PROCESS INCLUDING MEASURABLE CRITERIA FOR TEST ACCEPTANCE, PROVIDED HEREIN FOR REPEATABILITY. 2018 WSEC COMPLIANCE PROJECT SUMMARY ENERGY CODE SECTION COMPLIANCE REQUIREMENT TABLE C301.1 CLIMATE ZONE: 4C KING COUNTY C401 GENERAL COMPLIANCE SECTIONS C402, C403, C404, C405, C406, C408, C409, C410 & C411 SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS, AND CONNECTIONS OF SUPPLY AND RETURN DUCTS. MEDIUM PRESSURE (2-3 IN WC): SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS, AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND DUCT WALL PENETRATIONS HIGH PRESSURE (3+ IN WC): SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS, AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND DUCT WALL PENETRATIONS. IN ADDITION, DUCTS AND PLENUMS SHALL BE LEAK-TESTED IN ACCORDANCE WITH THE SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL WITH THE RATE OF AIR LEAKAGE (CL) LESS THAN OR EQUAL TO 4.0 AS DETERMINED IN ACCORDANCE WITH EQUATION 4-9. 6 ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.10.1.2 OF THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL. 7 WSEC C403.10.3 - ALL PIPING SERVING AS PART OF A HEATING OR COOLING SYSTEM SHALL BE THERMALLY INSULATED IN ACCORDANCE WITH TABLE C403.10.3 OF THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL. 1 C403.3.2 - HVAC EQUIPMENT SHALL MEET THE MINIMUM EFFICIENCY REQUIREMENTS OF TABLES C403.3.2(1), C403.3.2(2), C403.3.2(3), C403.3.2(4), C403.3.2(5), C403.3.2(6), C403.3.2(7), C403.3.2(8), C403.3.2(9), C403.3.2(10), C403.3.2(11), AND C403.3.2(12) OF THE WSEC AND AS INDICATED IN THE CONTRACT DOCUMENTS. 2 WHERE USED TO CONTROL BOTH HEATING AND COOLING, ZONE THERMOSTATIC CONTROLS SHALL PROVIDE A TEMPERATURE RANGE OR DEADBAND OF AT LEAST 5°F (2.8°C) WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY TO THE ZONE IS CAPABLE OF BEING SHUT OFF OR REDUCED TO A MINIMUM IN ACCORDANCE WITH SECTION C403.4.1.2 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 3 AUTOMATIC TIME CLOCK OR PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK AND RETAINING THEIR PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST 10 HOURS. ADDITIONALLY, THE CONTROLS SHALL HAVE A MANUAL OVERRIDE THAT ALLOWS TEMPORARY OPERATION OF THE SYSTEM FOR UP TO 2 HOURS; A MANUALLY OPERATED TIMER CAPABLE OF BEING ADJUSTED TO OPERATE THE SYSTEM FOR UP TO 2 HOURS; OR AN OCCUPANCY SENSOR IN ACCORDANCE WITH SECTION C403.4.2.2 OF THE WSEC AND DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 4 PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTIONS C408.2.2 (HVAC SYSTEMS), C408.2.2.1 (AIR SYSTEMS), AND C408.2.2.2 (HYDRONIC SYSTEMS) OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 5 ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE IMC. ALL DUCTWORK SHALL BE SEALED AND TESTED AS REQUIRED BY SECTIONS C403.10.1 AND C403.10.2 OF THE WSEC. DUCT TAPE IS NOT PERMITTED AS A SEALANT ON ANY DUCTS. DUCTWORK STATIC PRESSURE AND SEAL CLASS LOW PRESSURE (1/2-2 in wc): 15 ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE FLOORS SHALL BE PLACED ON AN INCOMPRESSIBLE, INSULATED SURFACE WITH A MINIMUM THERMAL RESISTANCE OF R-10 IN ACCORDANCE WITH SECTION C404.5 OF THE WSEC. 16 WSEC C404.7 - CIRCULATING HOT WATER SYSTEM PUMPS SHALL BE CONTROLLED IN ACCORDANCE WITH SECTION C404.7.1 OF THE WSEC. HEAT TRACE TEMPERATURE SYSTEMS SHALL BE CONTROLLED IN ACCORDANCE WITH SECTION C404.7.2 OF THE WSEC. HOT WATER STORAGE SYSTEM PUMPS SHALL BE CONTROLLED IN ACCORDANCE WITH SECTION C404.7.3 OF THE WSEC. 17 ELECTRIC MOTOR EFFICIENCY SHALL COMPLY WITH SECTION C405.8 AND SHALL NOT BE LESS THAN THE CORRESPONDING VALUES FOR ENERGY EFFICIENT MOTORS PROVIDED IN TABLES C405.8(1) THROUGH C405.8(4) OF THE WSEC WHEN TESTED AND RATED IN ACCORDANCE WITH DOE 10 CFR. 18 RECORD DOCUMENTS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C103.6.1 OF THE WSEC. CONSTRUCTION DOCUMENTS SHALL BE UPDATED TO CONVEY A RECORD OF THE ALTERATIONS TO THE ORIGINAL DESIGN. SUCH UPDATES SHALL INCLUDE UPDATED MECHANICAL, PLUMBING, AND CONTROL DRAWINGS THAT SHOW ALL CHANGES TO SIZE, TYPE AND LOCATIONS OF COMPONENTS, EQUIPMENT AND ASSEMBLIES. 19 OPERATING AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AND INCLUDE ALL OF THE FOLLOWING PER SECTION C103.6.2 OF THE WSEC. 1. SUBMITTAL DATA 2. OPERATION AND MAINTENANCE DATA FOR EQUIPMENT 3. NAME AND ADDRESS OF AT LEAST ONE SERVICE AGENCY 8 FOR ALL OCCUPANCIES OTHER THAN GROUP R, EACH ZONE SHALL BE PROVIDED WITH THERMOSTATIC SETBACK CONTROLS THAT ARE CONTROLLED BY EITHER AN AUTOMATIC TIME CLOCK OR PROGRAMMABLE CONTROL SYSTEM IN ACCORDANCE WITH SECTION C403.4.2 9 SUPPLY AIR AND WATER TEMPERATURES SHALL BE AUTOMATICALLY RESET AS REQUIRED IN SECTION C403.6.4 (AIR) AND C403.4.4 (WATER) OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 10 WSEC C403.5 - EACH COOLING SYSTEM THAT HAS A FAN SHALL INCLUDE AN AIR ECONOMIZER MEETING THE REQUIREMENTS OF SECTIONS C403.5.1 THROUGH C403.5.5 11 ECONOMIZER SYSTEMS SHALL BE INTEGRATED WITH THE MECHANICAL COOLING SYSTEM AND BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHERE ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD IN ACCORDANCE WITH SECTION C403.5.1 OF THE WSEC. 12 WATER ECONOMIZER SYSTEMS SHALL BE CAPABLE OF COOLING SUPPLY AIR BY INDIRECT EVAPORATION AND PROVIDING UP TO 100 PERCENT OF THE EXPECTED SYSTEM COOLING LOAD AT OUTDOOR AIR TEMPERATURES OF NOT GREATER THAN 50-DEG F DB/45 DG-F WET BULB IN ACCORDANCE WITH SECTION C403.5.4.1 OF THE WSEC. 13 SIMULTANEOUS HEATING AND COOLING TO INDIVIDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES EXCEPT WHERE PERMITTED IN SECTION C403.4.1 OF THE WSEC. 14 VARIABLE FREQUENCY DRIVES SHALL BE PROVIDED FOR VARIABLE FLOW HEATING AND AIR HANDLING SYSTEMS AS REQUIRED BY SECTION C403.2.3 OF THE WSEC AND AS DESCRIBED IN THE CONTRACT DOCUMENTS INCLUDING TEMPERATURE CONTROL SEQUENCES. AIR DISTRIBUTION AND PIPING DESIGN CRITERIA DUCT TYPE MAXIMUM PRESSURE DROP [IN WC/100', UNO] MAXIMUM VELOCITY [FPM]NOTES PASSIVE RETURN (NO FAN)0.05 500 RETURN (FAN ASSISTED)0.15 1,500 2. DUCTWORK DOWNSTREAM OF TERMINAL UNITS, FAN POWERED AND SINGLE DUCT 3. DUCTWORK UPSTREAM OF TERMINAL UNITS, FAN POWERED AND SINGLE DUCT 4. MAXIMUM RECOMMENDED DUCT AIRFLOW VELOCITY TO MAINTAIN NC-35 PER 2019 ASHRAE HVAC FUNDAMENTALS 5. VELOCITY BASED ON NET FREE AREA TO AVOID WATER INTRUSION OUTLET LOUVER 0.15 IN WC 750 NOTES: 1. REFER TO DETAIL FOR MAXIMUM LENGTH, MINIMIZE QUANTITY OF 90° BENDS. REFER TO GRILLE SCHEDULE FOR RUN-OUT SIZE GENERAL EXHAUST 0.08 - 0.1 1,500 LOW-PRESSURE SUPPLY (MAIN) 0.08 - 0.1 1,000 2 LOW-PRESSURE SUPPLY (BRANCH) 0.08 - 0.1 1,000 2 FLEXIBLE SUPPLY 0.08 - 0.1 1,000 1 PIPING (OCCUPIED SPACE) 4 FT HEAD/100' 8 FPS PIPING (MECHANICAL SPACE, SHAFTS, ETC.) 4 FT HEAD/100' 10 FPS COOLING COIL AIRSIDE 0.6 IN WC 450 HEATING COIL AIRSIDE 0.2 IN WC 450 INLET LOUVER 0.1 IN WC 500 5 EXISTING AHU MEDIUM-PRESSURE SUPPLY (ROUND) 0.15 3,000 3, 4 EXISTING AHU MEDIUM-PRESSURE SUPPLY (RECTANGULAR) 0.15 1,800 3, 4 DOAS MEDIUM-PRESSURE SUPPLY (ROUND) 0.15 3,000 3, 4 DOAS MEDIUM-PRESSURE SUPPLY (RECTANGULAR) 0.15 1,800 3, 4 7. FIRE WRAP AS INDICATED ON PLAN. 5. REINFORCED VINYL HOSE WITH SMOOTH INTERIOR SURFACE AND REINFORCED WITH HEAVY DUTY WIRE 0.05" THICK; PENN STATE INDUSTRIES PN #D08/ #D50 OR EQUIVALENT. 6. PROVIDE STANDARD ALUMINUM BLAST GATE WITH GALVANIZED STEEL SLIDE. GATE TO FIT INTO DUCT ENDS AND BE PROVIDED WITH A LOCKING SCREW TO HOLD POSITION; McMASTER-CARR PN #1788K14/ #1788K12 OR EQUIVALENT. 3. REFERENCE MATERIAL INSULATION MATRIX FOR INSULATION R-VALUE, VAPOR BARRIER, ETC. MATERIAL MATRIX TAKES PRECEDENCE OVER THIS SCHEDULE. 4. USE SMOOTH-WALL GALVANIZED OR ALUMINUM DUCT FOR MAIN AND CONNECT TO BLOWER WITH WIRE-REINFORCED FLEXIBLE TUBING. DUCT WORK SHALL NOT BE CONNECTED WITH SHEET METAL SCREWS OR OTHER FASTENERS THAT WILL OBSTRUCT AIRFLOW OR COLLECT DEBRIS. NOTES: 1. PRESSURE CLASS BASED ON SMACNA STANDARDS. 2. INDICATES IF PRESSURE TEST IS TO BE PERFORMED, OR AS INDICATED. PRESSURE TEST TO CONFORM WITH SMACNA STANDARDS. LIGHT TEST TO CONFORM WITH CODE. FLEX AT DIFFUSER +2" NA NO G-KM NO DUCTWORK PRESSURE CLASS DESIGN CRITERIA SYSTEM SUPPLY DUCT PRESSURE CLASS [IN WG] [1] RETURN/EXHAUST DUCT PRESSURE CLASS [IN WG] [1] INSULATION APPLICATION [3]MATERIAL PRESSURE TEST REQUIRED [2] MEDIUM PRESSURE SUPPLY - AHU TO FT +2" NA YES GALVANIZED YES LOW PRESSURE SUPPLY - FT TO GRD'S +2" NA NO GALVANIZED NO GENERAL EXHAUST FAN +2" -2" NO GALVANIZED NO BLOWER FAN +2" -10" NO GALVANIZED [4]NO TOTAL DOAS 5,930 5,365 150 DESCRIPTION SYSTEM PEOPLE GROSS AREA (SF) EXHAUST AIRFLOW (CFM) OUTSIDE AIR (CFM) SPACE PRESSURE TRAINING 104 DOAS 6 585 0 440 "-" DEFIANCE WEIGHT ROOM 105 DOAS 11 970 700 800 "+" JANITOR 164 DOAS 0 25 50 "-" SHOWERS 165 DOAS 8 305 400 "-" COACH LOCKER 147 DOAS 4 305 300 240 150 MEDICAL TRAINING 138 DOAS 10 1,295 700 750 "-" MED & PERF 147 DOAS 10 1,060 260 360 "+" TEAM LOCKER 161 DOAS 25 1,470 620 540 "-" DEFIANCE LOCKER 106 DOAS 24 740 555 325 "-" ACADEMY LOCKER 107 DOAS 26 590 465 280 "-" WOMEN LOCKER 108 DOAS 5 400 230 150 "-" STAFF LOCKER 109 DOAS 18 850 600 480 "-" JANITOR 110 DOAS 0 25 50 0 "-" WEIGHT ROOM 137 DOAS 20 2,445 500 600 "+" STORAGE 160 DOAS 0 100 100 0 "-" GROOMING 162 DOAS 6 467 0 400 "-" TOILETS 163 DOAS 8 210 400 "-" PROJECT TOTALS 775,870 100.0%145,640 745,672 891,311 100.00% 74 Tons HEATING AND COOLING LOAD RECAP PROJECT NAME:8833 Sounder HQ Practice Facility DATE 10/3/2022 WEATHER DATA LOCATION SEATTLE-BOEING FLD, WASHINGTON, USA SAFETY FACTORS OUTDOOR SUMMER DB: 86ºF SENSIBLE 1.10 OUTDOOR SUMMER WB: 66ºF LATENT 1.05 OUTDOOR WINTER DB: 24ºF HEATING 1.20 #DESCRIPTION SETPOIN T HTG CFM TOTAL BTUH BTUH/SF CFM % OA TO HTG CFM % OA TO CLG CFM LVG. COIL DB ENTERING. COIL DB CFM/SF 1 LANDLORD-AHU 73ºF 9,840 500,129 16 4,379 44%28%85.0 55.6 0.3 2 DOAS-1 72ºF 85,288 275,741 25 2,591 3% 28% 73.0 70.8 7.7 95,127 775,870 6,970 PROJECT LOAD AREA SEN. LOSS %TOT LATENT SENS. TOTAL %TOT GLAZING SUMMARY ROOF 0 0 0.00% 0 0 0.00%% OF % WALL % OF AIR SYSTEM INDOOR BLOCK PEAK CFM COIL DATA # DESCRIPTION SETPOIN T CFM CFM DIV. SENS. GAIN TOTAL BTUH SENS. RATIO TONS CFM/SF SF/TON CFM/TO N LVG. COIL DB LVG. COIL WB LVG. COIL RH LVG COIL ENTHALPY ENT. COIL DB ENT. COIL WB ENTERING COIL RH ENT. COIL ENTHALPY 1 LANDLORD-AHU 75ºF 15,901.51 16,355.58 0.97 479,669 552,622 0.87 46.1 0.52 661 345 55 53.5 90.8 22.3 80.0 64.3 42.5 29.3 2 DOAS-1 75ºF 9,170.45 9,416.83 0.97 224,334 293,589 0.76 24.5 0.82 455 375 60 54.4 70.0 22.8 80.2 64.3 41.9 29.4 25,072 25,772 704,003 846,211 71 FILL OUT VENT CALC TAB PEOPLE (NUMBER)487 0.00% 145,861 160,145 306,006 34.33%VENTILATION (CFM)6,970 513,053 66.13% -299 91,500 91,201 10.23%INFILTRATIO N (CFM)168 10,418 1.34% 77 2,029 2,106 0.24% DRAW FAN 0.00% 0 0 0.00% BLOW FAN 0.00% 83,503 83,503 9.37% SUPPLY DUCT 0 0.00% 0 0 0.00% RETURN DUCT 0 0.00% 0 0 0.00% RESERVE 0 0.00% 0 0 0.00% WALL 1,567 8,935 1.15% 1,433 1,433 0.16%SYS #WALL & PART.AREA GLASS 4,031 71,970 9.28% 121,705 121,705 13.65% 1 76% 16% 9% SKYLIGHT 0 0 0.00% 0 0 0.00%2 66% 11% 12% PARTITION 24,411 161,113 20.77% 29,537 29,537 3.31%Total 72% 13% 13% FLOOR SLAB 10,381 1.34%0 0.00% SKIN LOADS 30,009 252,398 32.53% 0 152,675 152,675 17.13% LIGHTING 0.00% 107,370 107,370 12.05% EQUIPMENT 0.00% 148,449 148,449 16.66% COOLING LOAD BREAKDOWN FILL OUT VENT CALC TAB AIR SYSTEM ROOF WALL WINDOW SKYLIGHT PARTITION LIGHTS EQUIPMENT PEOPLE OUTSIDE AIR # DESCRIPTION AREA AREA SENS. GAIN LOAD % AREA SENS. GAIN LOAD % AREA SENS. GAIN LOAD % AREA SENS. GAIN LOAD % AREA SENS. GAIN LOAD % BTUH W/SF LOAD % BTUH W/SF LOAD % QUANTITY SF/PERSON TOTAL BTUH LOAD % CFM SENS. GAIN 1 LANDLORD-AHU 30,445 0 0 0.0% 843 844 0.2% 2,652 85,791 15.5%0 0 0.0% 13,605 16,462 100.7% 77,383 0.74 14.0% 122,855 1.18 22.2% 323 94 162,527 29.4% 4,379 57,484 2 DOAS-1 11,130 0 0 0.0% 724 589 0.2% 1,378 35,914 12.2% 0 0 0.0%10,806 13,075 138.8% 29,987 0.79 10.2% 25,594 0.67 8.7% 164 68 135,720 46.2% 2,591 34,016 41,575 0 0 1,567 1,433 4,031 121,705 0 0 24,411 29,537 107,370 148,449 487 298,246 6,970 91,500 AIR SYSTEM ROOF WALL WINDOW SKYLIGHT PARTITION OUTSIDE AIR INFILTRATION SLAB MISC. # DESCRIPTION AREA AREA SENS. LOSS LOAD % AREA SENS. LOSS LOAD % AREA SENS. LOSS LOAD % AREA SENS. LOSS LOAD % AREA SENS. LOSS LOAD % CFM CFM/PERSON SENS. LOSS LOAD % CFM SENS. LOSS LOAD % PERIMETER SENS. LOSS LOAD % BTUH LOAD % 1 LANDLORD-AHU 30,445 0 0 0.0% 741 4,807 1.0% 2,652 47,356 9.5% 0 0 0.0% 13,605 89,793 18.0% 4,379 14 347,753 69.5% 106 6,579 1.3% 124 3,841 0.8% 0 0.0% 2 DOAS-1 11,130 0 0 0.0% 724 4,129 1.5% 1,378 24,614 8.9% 0 0 0.0% 10,806 71,320 25.9% 2,591 16 165,301 59.9% 62 3,839 1.4% 210 6,540 2.4% 0 0.0% 41,575 0 0 1,465 8,935 4,031 71,970 0 0 24,411 161,113 6,970 513,053 168 10,418 334 10,381 0 AIR SYSTEM INDOOR HEATING TOTALS OUTSIDE AIR COIL DATA HEATING © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:13:41 AM3/13/2023 9:13:41 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M003 PERMIT NOTES AND CALCULATIONS 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE 50% DD 02/27/2023 4. SUMMER INDOOR SET POINT TO VARY. REFER TO "HVAC DESIGN CRITERIA." 5. INFILTRATION LOAD ONLY ADDED IN ZONES AT EXTERIOR. 2. BASED ON ASHRAE FUNDAMENTALS HEAT AND MOISTURE EMITTED BY HUMAND BASED ON ACTIVITY LEVEL. 3. DEFAULT OCCUPANT DENSITY TO BE USED ONLY IF EXPECTED OCCUPANT COUNT IS NOT PROVIDED; REFERENCE ARCHITECURAL FURNITURE PLAN FOR OCCUPANT COUNT. MEDICAL TRANING 5 CFM/ PPL 0.06 CFM/ SF NA 100 SF/ PPL 250 200 74°F +/- 2°F 0.7 W/SF 1.0 W/SF NA VIDEO EDIT 5 CFM/ PPL 0.06 CFM/ SF NA 50 SF/ PPL 250 200 74°F +/- 2°F 0.7 W/SF 150W/ PERSON 100W/ TV NA NA = NOT APPLICABLE NOTES: 1.VENTILATION AIR WILL BE PROVIDED PER THE 2018 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS. TOILET ROOM EXHAUST MAKEUP AIR 75 CFM/ FIXTURE (URINAL & WC)NA 250 200 74°F +/- 2°F NA NA JANITORS ROOM EXHAUST MAKEUP AIR - TRANSFER FROM ADJACENT SPACE 1.0 NA -- --74°F +/- 2°F NA NA IDF SPACE -- ---- -- --74°F +/- 2°F 0 -- 3 TON PENDING FINAL COORDINATION MDF SPACE -- ---- -- --74°F +/- 2°F 0 -- 6 TON PENDING FINAL COORDINATION WEIGHT ROOM 20 CFM/ PPL 0.06 CFM/ SF NA 100 SF/ PPL 710 1090 74°F +/- 2°F 0.75 W/SF 1.0 W/SF 0.3 ACH LOAD PENDING EQUIPMENT LIST PLAYER LOUNGE/ CAFÉ SPONSOR AREA 5 CFM/ PPL 0.06 CFM/ SF NA 50 SF/ PPL 250 200 74°F +/- 2°F 0.86 W/SF 3.0 W/ SF 0.3 ACH LOAD PENDING EQUIPMENT LIST EXAM/ TREATMENT 5 CFM/ PPL 0.06 CFM/ SF NA 200 SF/ PPL 250 200 74°F +/- 2°F 0.7 W/SF 0.5 W/SF NA BARBER 7.5 CFM/ PPL 0.06 CFM/ SF 0.5 (2) PEOPLE PER ROOM 250 200 74°F +/- 2°F 0.7 W/SF 0.5 W/SF NA MEDICAL WORKSPACE 5 CFM/ PPL 0.06 CFM/ SF NA 50 SF/ PPL 250 200 74°F +/- 2°F 0.7 W/SF 150W/ PERSON 100W/ TV NA HVAC VENTILATION AND THERMAL DESIGN CRITERIA SPACE MINIMUM PEOPLE VENTILATION RATE [1] MINIMUM AREA VENTILATION RATE [1] EXHAUST AIRFLOW RATE (CFM/SF) DEFAULT OCCUPANT DENSITY PER TABLE 403.3.1.1 [2,3,4] SENSIBLE HEAT PER PERSON [5] LATENT HEAT PER PERSON [5] SPACE TEMPERATURE [6] LIGHTING EQUIPMENT INFILTRATION [7]NOTES PRIVATE OFFICE/ WORK ROOM 5 CFM/ PPL 0.06 CFM/ SF NA 100 SF/ PPL 250 200 74°F +/- 2°F 0.7 W/SF 400 W/SF 0.3 ACH COOLING LOAD ESTIMATE BASED ON HEAVY LOAD DENSITY OPEN WORK/ TICKET SALES 5 CFM/ PPL 0.06 CFM/ SF NA 150 SF/ PPL 250 200 74°F +/- 2°F 0.7 W/SF 150W/ PERSON 0.3 ACH COOLING LOAD ESTIMATE BASED ON HEAVY LOAD DENSITY CONFERENCE/ MEETING ROOM/ CLASSROOM 5 CFM/ PPL 0.06 CFM/ SF NA 50 SF/ PPL 250 200 74°F +/- 2°F 0.7 W/SF 50W/ PERSON 150W/ PROJECTOR 0.3 ACH COOLING LOAD ESTIMATE BASED ON HEAVY LOAD DENSITY PHONE ROOM 5 CFM/ PPL 0.06 CFM/ SF NA (1) PERSON PER ROOM 250 200 74°F +/- 2°F 0.7 W/SF 50W/ PERSON NA CORRIDORS -- 0.06 CFM/ SF NA -- -- --74°F +/- 2°F 0.41 W/SF -- 0.3 ACH STORAGE ROOM -- 0.12 CFM/ SF TBD -- -- --74°F +/- 2°F 0.7 W/SF -- 0.3 ACH EXHAUST TO BE EVALUATED FOR SOILED OR ORDOROUS EQUIPMENT STORAGE LOCKER ROOM EXHAUST MAKEUP AIR 0.5 (1) PERSON PER LOCKER W/ 80% DIVERSITY 250 200 74°F +/- 2°F NA NA ADDITIONAL EXHAUST REQUIRED AT EACH PLAYERS LOCKER SHOWER ROOM EXHAUST MAKEUP AIR 50 CFM/ FIXTURE NA 250 200 74°F +/- 2°F NA NA [2]BREATHING ZONE OUTDOOR AIR, ASHRAE 62.1 EQUATION 6-1 [3] ZONE OUTDOOR AIR, ASHRAE 62.1 EQUATION 6-2 [4] 100% OUTDOOR AIR SYSTEMS, ASHRAE 62.1 EQUATION 6-4 [5] AREAS SHOWN ARE FOR VENTILATION CALCULATIONS ONLY AND ARE NOT TO BE USED FOR RENTABLE SQUARE FOOTAGE. LEASABLE AREA QUANTITIES SHALL BE NEGOTIATED WITH THE OWNER. [6] INCREASE TO PROVIDE SAFETY FACTOR. ELECTRICAL 132 275 NA 0 0 0.06 1.00 20 0.0 0 0 VIDEO 151 97 50 2 5 0.06 1.00 20 1.0 20 25 [1] OCCUPANT DENSITY AND VENTILATION RATES PER BOD AND SMC TABLE 403.3 STAFF LOCKER 109 850 NA NA 5 0.50 1.00 425 0.8 535 695 JANITOR 110 36 NA NA 5 0.06 1.00 5 1.0 5 5 GROOMING 162 TOILETS 163 SHOWERS 165 JANITOR 164 1,100 NA NA 5 0.06 1.00 70 0.8 90 115 TEAM LOCKERS 161 STORAGE 160 1,365 NA NA 0 0.50 1.00 685 0.8 860 1,120 JANITOR 152B COACH LOCKER 152 335 NA NA 5 0.25 1.00 85 0.8 110 145 CORRIDOR 102 TRAINING 104 753 100 8 20 0.06 1.00 200 0.8 250 325 DEFIANCE/ACADEMY WEIGHT RM 105 1,025 100 10 10 0.06 1.00 165 0.8 210 275 DEFIANCE LOCKER 106 750 NA NA 5 0.50 1.00 375 0.8 470 610 ACADEMY LOCKER 107 570 NA NA 5 0.50 1.00 285 0.8 360 470 WOMEN LOCKER 108 385 NA NA 5 0.50 1.00 195 0.8 245 320 HEAD EQUIPMENT 156 EQUIPMENT 155 LAUNDRY 154 PRINT ROOM 153 1,830 100 18 25 0.00 1.00 460 0.8 575 750 COACHES WORK 150 HEAD COACH 149 830 100 8 5 0.06 1.00 95 0.8 120 155 MEDICAL AND PERFORMANCE 147 980 50 20 5 0.06 1.00 160 0.8 200 260 WEIGHT ROOM 137 2,778 100 28 10 0.06 1.00 445 0.8 560 730 EXAM 144 HEAD MEDICAL 143 315 200 2 5 0.06 1.00 30 1.0 30 40 CORRIDOR 157 SECONDARY BOOT 148 880 NA NA 5 0.06 1.00 55 1.0 55 70 PLAYER LOUNGE 136 1,200 50 24 5 0.18 1.00 340 0.8 425 555 BARBER 135 130 2 PEOPLE PER ROOM 2 8 0.06 1.00 25 1.0 25 35 LOUNGE ENTRY 133 BOOT CLEANING 134 245 NA NA 5 0.06 1.00 15 1.0 15 20 IDF 120 96 NA 0 0 0.00 1.00 0 0.8 0 0 MEDICAL TRAINING 138 HEAD PERFORMANCE 139 1,375 100 14 5 0.06 1.00 155 0.8 195 255 COACHES WORKSPACE 112 WORK 113 830 100 8 5 0.06 1.00 95 1.0 95 125 STUDIO 115 3RD PARTY PRESS 117 580 150 4 5 0.06 1.00 55 1.0 55 70 TEAM LECTURE 118 720 50 14 10 0.12 1.00 235 1.0 235 305 INTERNAL CONTROLS 119 ADMIN WORK 120 WORK 121 WORK 122 855 100 9 5 0.06 1.00 95 1.0 95 125 MINIMUM VENTILATION CALCULATION - FIRST FLOOR LEVEL ROOM AREA OCCUP. DENSITY PEOPLE CFM/PERSON CFM/SF PEOPLE VBZ EZ VOZ INCREASE [6] SQ.FT. [5] PPL/1000 SF [1]DIVERSITY 1 CLASSROOM 103 650 50 13 10 0.12 1.00 210 0.8 265 345 2 MINIMUM VENTILATION CALCULATION - SECOND FLOOR LEVEL ROOM AREA OCCUP. DENSITY PEOPLE CFM/PERSON CFM/SF PEOPLE VBZ EZ VOZ INCREASE [6] SQ.FT. [5] PPL/1000 SF [1] [1] [1] DIVERSITY [1] OCCUPANT DENSITY AND VENTILATION RATES PER BOD AND WA STATE MECHANICAL CODE 2015 TABLE 403.3.1.1 [2] BREATHING ZONE OUTDOOR AIR, ASHRAE 62.1 EQUATION 6-1 [3] ZONE OUTDOOR AIR, ASHRAE 62.1 EQUATION 6-2 [4] 100% OUTDOOR AIR SYSTEMS, ASHRAE 62.1 EQUATION 6-4 [5] AREAS SHOWN ARE FOR VENTILATION CALCULATIONS ONLY AND ARE NOT TO BE USED FOR RENTABLE SQUARE FOOTAGE. LEASABLE AREA QUANTITIES SHALL BE NEGOTIATED WITH THE OWNER. [6] INCREASE TO PROVIDE ALLOWANCE FOR LEED CREDITS - REFER TO LEED DOCUMENTATION FOR LEED VENTILATION CALCULATION. 2-WP-218-SOCCER SVP 165 100 2 5 0.06 1.00 20 0.8 25 2-INT-219-WAR ROOM 165 100 6 5 0.06 1.00 40 1.0 40 2-INT-220-OWNER 320 100 3 5 0.06 1.00 40 1.0 40 2-WP-221-RAVE GREEN LOUNGE 305 50 6 5 0.06 1.00 50 0.8 65 2-INT-222-CAFE/BREAK-INT SEATING 1,335 50 27 5 0.06 1.00 215 0.8 270 2-WP-222-CAFE/BREAK-EXTERIOR 520 50 10 5 0.06 1.00 85 1.0 85 2-INT-228 - OFFICE # 3 465 50 12 5 0.06 1.00 90 1.0 90 1,970 =TOTAL 2-INT-202-STORAGE/HALLWAY 3,500 1 8 5 0.06 1.00 250 1.0 250 2-INT-205-LARGE CONFERENCE 435 50 9 5 0.06 1.00 70 1.0 70 2-INT-206-OPEN WORK 2,660 150 18 5 0.06 1.00 250 1.0 250 2-INT-207 - OFFICE # 1 362 100 8 5 0.06 1.00 65 1.0 65 2-INT-211-OFFICE #2 240 100 4 5 0.06 1.00 35 1.0 35 2-INT-213-CONFERENCE #2 200 50 4 5 0.06 1.00 35 0.8 45 2-INT-214- INT OPEN WORK #1 2,400 150 16 5 0.06 1.00 225 1.0 225 2-INT-214- INT OPEN WORK #2 2,420 150 16 5 0.06 1.00 230 1.0 230 2-SP-214-OPEN WORK-EXTERIOR 757 150 5 5 0.06 1.00 75 0.8 95 2-SP-216-SOCCER OPS WORKSPACE 620 100 6 5 0.06 1.00 70 0.8 90 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:13:46 AM3/13/2023 9:13:46 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M004 PERMIT NOTES AND CALCULATIONS 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 Author 1901 OAKESDALE AVENUE SW RENTON, WA 98057 Checker REV DESCRIPTION DATE 50% DD 02/27/2023 SECONDARY DRAIN CONNECTION YES YES YES YES YES YES YES YES DRAIN PAN FLOAT SWITCH YES YES YES YES YES YES YES YES VIBRATION ISOLATION YES YES YES YES YES YES YES YES BOTTOM ACCESS ELECTRICAL PANEL YES YES YES YES YES YES YES YES BOTOOM ACCESS FILTER YES YES YES YES YES YES YES YES NOTES NOTES: 1. EXTERNAL STATIC PRESSURE IS EXTERNAL TO THE UNIT AND DOES NOT INCLUDE AN ALLOWANCE FOR DIRTY FILTERS AS INDICATED. 2. TOTAL STATIC PRESSURE SHALL INCLUDE INTERNAL COMPONENTS PLUS SCHEDULED ALLOWANCES FOR FILTER LOADING. 3. DELUX PIPING PACKAGE: STRAINER AND SHUTOFF VALVE ON SUPPLY LINE, CONTROL VALVE AND MANUAL CIRCUIT SETTER RETURN LINE. 4. SYSTEMS COMPLYING WITH SECTION C403.3.5 DEDICATED OUTSIDE AIR SYSTEM (DOAS) AND C403.5 ECONOMIZER EXCEPTION 1 5. ELECTRICAL CONTRACTOR TO PROVIDE 120V CIRCUIT FOR CONDENSATE PUMP 6. FAN COIL UNIT SHALL OPERATE IN COMPLIANCE WITH WSEC C403.3.5.2 EXCEPTION FOR MINIMUM AIRFLOW AT 0.12 W/CFM SHALL BE CONFIRMED WITH FINAL SUBMITTAL FAN COIL UNIT HYDRONIC SCHEDULE TAG FCU1-111 FCU1-211 FCU1-411 FCU1-511 FCU1-512 FCU1-513 FCU1-412 FCU2-101 SYSTEM AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 SERVICE 20011FCUG-1 20011FCUC-2 20011FCUC5-55 20011FCUA-5 20011FCUC-5 20011FCUD-5 20011FCUF-4 20012FCUB-5 LOCATION DEFIANCE/ACADE MY WEIGHT ROOM 105 IDF ROOM 116 ALTITUDE EQUIPMENT 141 WEIGHT ROOM 137 WEIGHT ROOM 137 MEDICAL AND PERFORMANCE TRAINING 152 EQUIPMENT 155 MDF ROOM 215 EQUIPMENT MANUFACTURER JCI JCI JCI JCI JCI JCI JCI JCI MODEL FNP 8 FNP 12 FNP 6 FNP 8 FNP 12 FNP 6 FNP 8 FNP 20 CABINET STYLE CABINET INSULATION TYPE CABINET INSULATION THICKNESS (IN) MOUNTING SUSPENDED SUSPENDED SUSPENDED SUSPENDED SUSPENDED SUSPENDED SUSPENDED SUSPENDED SUPPLY FAN MAX FAN AIRFLOW (CFM) 800 1,200 300 800 1,200 500 800 1900 MIN FAN AIRFLOW (CFM) 800 1,200 300 800 1,200 500 800 1900 MIN PRIMARY AIR (CFM)NA NA 300 NA NA NA NA NA ESP @ MAX (IN WC) (1)0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 TSP @ MAX (IN WC) (2)0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 SPEED (RPM)1252 148 760 1252 1161 1061 1252 1,231 DRIVE TYPE ECM ECM ECM ECM ECM ECM ECM ECM FAN ISOLATION TYPE CHILLED WATER COIL TOTAL COOLING (MBH)22.6 38.4 9.9 22.6 36 14.6 22.6 66.4 SENSIBLE COOLING (MBH) 17.6 38.4 9.8 17.6 27 11.3 17.6 66.4 EWT (DEG F)44 48 44 44 44 44 44 48 LWT (DEG F)56 60 56 56 56 56 56 60 WATER FLOW (GPM)3.90 6.70 1.8 3.90 6.40 2.50 3.90 11.3 LAT (DEG F)87 NA NA 87 87 88 87 NA ROWS 1 NA NA 1 1 1 1 NA FINS PER INCH 10 NA NA 10 10 10 10 NA AIR PRESSURE DROP (IN WC) 0.08 NA NA 0.08 0.03 0.06 0.08 NA CONTROL VALVE TYPE 2-WAY NA NA 2-WAY 2-WAY 2-WAY 2-WAY NA VENTILATION [4] MINIMUM AIRFLOW (CFM) NA NA NA NA NA NA NA NA PERCENT ECONOMIZER NA NA NA NA NA NA NA NA ECONOMIZER TYPE NA NA NA NA NA NA NA NA FILTERS TYPE MERV 8 MERV 8 MERV 8 MERV 8 MERV 8 MERV 8 MERV 8 NA FACE SIZE (IN X IN)16 X 20 (2) 16 X 16 16 X 16 16 X 20 (2) 16 X 16 16 X 16 16 X 20 THICKNESS (IN)2 2 2 2 2 2 2 WATER PRESSURE DROP (FT PD) 4.93 6.86 7.2 4.93 7.07 3.77 4.93 8.4 EAT DB/WB (DEG F/DEG F) 74 85/63 85/63 74 74 74 74 85/63 LAT DB/WB (DEG F/DEG F) 55 56/52 55/51 55 55 55 55 55/51 ROWS 6 6 3 6 6 6 6 6 FINS PER INCH 10 10 12 10 10 10 10 12 AIR PRESSURE DROP (IN WC) 0.43 0.35 0.07 0.43 0.37 0.31 0.43 0.26 CONTROL VALVE TYPE 2-WAY 2-WAY 2-WAY 2-WAY 2-WAY 2-WAY 2-WAY 2-WAY HEATING WATER COIL TOTAL HEATING (MBH)19.7 NA NA 19.7 28.6 12,478 19.7 NA EWT (DEG F)155 NA NA 155 155 155 155 NA LWT (DEG F)135 NA NA 135 135 135 135 NA WATER FLOW (GPM)1.90 NA NA 1.90 2.90 1.30 1.90 NA WATER PRESSURE DROP (FT PD) 0.58 NA NA 0.58 0.52 0.22 0.58 NA EAT (DEG F)65 NA NA 65 65 65 65 NA MERV RATING 8 8 8 8 8 8 8 MAX FACE VELOCITY (FPM) PRESSURE DROP CLEAN (IN WC) 0.17 0.15 0.11 0.17 0.15 0.11 0.17 PRESSURE DROP DIRTY (IN WC) ELECTRICAL MOTOR TYPE EC MOTOR EC MOTOR EC MOTOR EC MOTOR EC MOTOR EC MOTOR EC MOTOR EC MOTOR HP (1) 1/3 (1) 1/2 (1) 1/3 (1) 1/3 (1) 1/2 (1) 1/3 (1) 1/3 (2) 1/2 POWER NORMAL EMERGENCY NORMAL NORMAL NORMAL NORMAL NORMAL EMERGENCY VOLTS/PHASE 277/1 277/1 277/1 277/1 277/1 277/1 277/1 277/1 FLA 2.6 3.9 2.4 2.6 3.9 2.4 2.6 6.4 MCA 3.25 4.88 3 3.25 4.88 3 3.25 7.2 MOCP 15 15 15 15 15 15 15 15 STARTER BY EC BY EC BY EC BY EC BY EC BY EC BY EC BY EC DISCONNECT BY EC BY EC BY EC BY EC BY EC BY EC BY EC BY EC SCCR NA NA NA NA NA NA NA NA SOUND DATA 63 HZ DISCHARGE/RADIATED (DB/DB) NA NA NA NA NA NA NA NA 125 HZ DISCHARGE/RADIATED (DB/DB) 70/73 71/73 59/58 70/73 72/74 66/66 70/73 73/73 250 HZ DISCHADISCHARGE/RADIATED (DB/DB) 69/67 69/69 58/53 69/67 67/70 65/61 69/67 71/70 500 HZ DISCHADISCHARGE/RADIATED (DB/DB) 67/64 67/67 57/55 67/64 67/67 64/61 67/64 70/69 1000 HZ DISCHARGE/RADIATED (DB/DB) 68/66 67/67 54/54 68/66 67/68 63/62 68/66 72/72 2000 HZ IDISCHDISCHARGE/RADIATED (DB/DB) 64/63 64/62 49/49 64/63 64/63 59/58 64/63 67/67 4000 HZ DISCHARGE/RADIATED (DB/DB) 63/60 60/59 44/43 63/60 61/59 56/55 63/60 Jul-64 8000 HZ DISCHADISCHARGE/RADIATED (DB/DB) 55/54 52/54 35/36 55/54 52/54 47/48 55/54 60/60 PHYSICAL OPERATING WEIGHT (LBS) 142 196 112 142 221 124 142 235 DIMENSIONS - L X W X H (IN X IN X IN) 33 1/8 X 39 7/8 X 16 3/4 33 1/8 X 48 7/8 X 16 3/4 33 1/8 X 34 7/8 X 16 7/8 33 1/8 X 39 7/8 X 16 3/4 33 1/8 X 48 7/8 X 16 3/4 33 1/8 X 34 7/8 X 16 7/8 33 1/8 X 39 7/8 X 16 3/4 28 7/8 X 67 7/8 X 16 3/4 COOLING COIL PIPING IN/OUT (IN/IN) 7/8 7/8 7/8 7/8 7/8 7/8 7/8 1-1/8 HEATING COIL PIPING IN/OUT (IN/IN) 5/8 NA 5/8 5/8 5/8 5/8 5/8 NA CONDENSATE DRAIN (IN) 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 DISCHARGE COLLAR (IN X IN) 19 X 12 1/2 28 X 12 1/2 14 X 12 1/2 19 X 12 1/2 28 X 12 1/2 14 X 12 1/2 19 X 12 1/2 47 X 12 1/2 INLET COLLAR (IN X IN) 20 X 14 32 X 14 16 X 14 20 X 14 32 X 14 16 X 14 20 X 14 ACCESSORIES SMOKE DETECTOR NO NO NO NO NO NO NO NO ECONOMIZER NO NO NO NO NO NO NO NO CONDENSATE PUMP ASSEMBLY [5] YES YES YES YES YES YES YES YES COIL MANUAL AIR VENTS YES YES YES YES YES YES YES YES DELUX PIPING PACKAGE [3] NO NO NO NO NO NO NO NO MODULATING CONTROL VALVE YES YES YES YES YES YES YES YES REMOVABLE DRAIN PAN YES YES YES YES YES YES YES YES STAINLESS STEEL DRAIN PAN YES YES YES YES YES YES YES YES POWER CORD LENGTH (FT)BY ELECTRICAL FILTER SIZE (INCH)18 X 20 X 2 FILTER EFFICIENCY MERV 13 DEHUMIDIFIER SCHEDULE TAG DH1-141 AIR SYSTEM AHU2001 LOCATION 20011DHD5-4 AREA SERVED HYDROTHERAPY EQUIPMENT MANUFACTURER DECTRON MODEL NO.QUEST 876 TYPE HIGH EFFICIENCY DEHUMIDIFIER PERFORMANCE AIR FLOW (CFM)1,600 FAN SPEED CONTROL CONSTANT COMPRESSOR BUILT IN REMOTE CONDENSER NA REGRIGERANT R410A CHARGE (LB-OZ)6 LB and 4 OZ DRAIN CONNECTION (INCH)0.75 FURNISHED (MC/ EC)MC INSTALLED (MC/ EC)EC POWER NORMAL/EMERGENCY NORMAL CONTROLS BY CONTROL CONTRACTOR INTEFACE BMS PHYSICAL ELECTRICAL DATA VOLT/PHASE 208-230/1 AMPS 24.7 POWER (WATTS)5,500 MCA (AMPS)42.5 MOP (AMPS)70 DISCONNECT PRESSURE DROP (IN WC)0.4 TEMPERATURE OPERATING RANGE (DEG F) 56-110 WATER REMOVAL (GAL/HR)4.5 EFFICIENCY (PINTS/KWH)6.6 COOLING DX SUPPLY AIR TEMPERATURE (DEG F) 80 ENTERING AIR TEMPERATURE (DEG F) 70 LENGTH (IN)44.7 WIDTH (IN)28.9 HEIGHT (IN)33.8 OPERATING WEIGHT (LBS)340 ACCESSORIES DUCT ADAPTER RECTANGULAR 1. FAN MOTORS MUST MEET 2018 IECC MINIMUM EFFICIENCIES. 2. FAN TO RUN ON SCHEDULE WITH OVERRIDE CAPABILITY 3. PROVIDE SECONDARY LINT TRAP SUITABLE FOR 8" DUCT. 4. FAN TO BE INTERLOCKED WITH HYPOXICO EQUIPMENT GENERAL FAN SCHEDULE TAG EF1-100 SF1-100 DBF1-1 DBF1-2 DBF1-3 AIR SYSTEM AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 LOCATION 20011EFF-45 20011SFE-4 EQUIPMENT ROOM 155 EQUIPMENT ROOM 155 EQUIPMENT ROOM 155 SERVICE HYDROTHERAPY ALTITUDE LAUNDRY ROOM LAUNDRY ROOM LAUNDRY ROOM EQUIPMENT EMERGENCY POWER NO NO NO NO NO CONTROLS - REF ONLY NORMAL MODE AUTO AUTO AUTO AUTO AUTO CONTROL BY BMS BMS INTERLOCK W/DRYER INTERLOCK W/DRYER INTERLOCK W/DRYER PHYSICAL PERFORMANCE CFM 300 200 800 800 800 ESP 0.5 0.5 RPM 1418 1584 2700 2700 2700 ELECTRICAL BHP 0.07 0.03 318 WATTS 318 WATTS 318 WATTS MANUFACTURER GREENHECK GREENHECK FANTECH FANTECH FANTECH MODEL SQ-95-VG SQ-70-VG 6KVY5 6KVY5 6KVY5 FAN TYPE INLINE INLINE IN-LINE IN-LINE IN-LINE DRIVE DIRECT DIRECT DIRECT DIRECT DIRECT WHEEL TYPE BACKWARD INCLINE BACKWARD INCLINE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL WHEEL DIAMETER (IN) WEIGHT (LBS) 47 30 DISCHARGE POSITION HORIZONTAL HORIZONTAL VERTICAL VERTICAL VERTICAL ARR. SIZE W X L X H (IN) 15X16X15 14X15X14 12.5 X 12.5 X 15.5 12.5 X 12.5 X 15.5 12.5 X 12.5 X 15.5 ACCESSORIES SPEED CONTROL ECM ECM ECM ECM ECM VIBRATION ISOLATORS YES YES NO NO NO BACKDRAFT DAMPERS YES YES NO NO NO MOTOR GUARD NO NO NO NO NO LINT TRAP NA NA YES YES YES NOTES 1, 2 1, 4 3 3 3 NOTES: HP 1/4 1/15 VOLT/PHASE 110/1 110/1 110/1 110/1 110/1 POWER NORMAL NORMAL NORMAL NORMAL NORMAL STARTER ECM ECM ECM ECM ECM FURNISHED/INSTALLED MC/EC MC/EC MC/EC MC/EC MC/EC DISCONNECT BY EC BY EC BY EC BY EC BY EC FURNISHED/INSTALLED MC/EC MC/EC MC/EC MC/EC MC/EC NOTES: CHILLED WATER COOLING COIL SCHEDULE TAG CC1-100 AIR SYSTEM SF1-100 LOCATION 20011SFE-4 SERVICE ALTITUDE EQUIPMENT MANUFACTURER RAE COILS MODEL 58W12X12-12-3-W-E-R ACCESSORIES CONDENSATE PAN YES xxxx-coil-cooling.x2a AIRSIDE PERFORMANCE TOTAL COOLING (MBH)8.7 SENSIBLE COOLING (MBH) 8.6 EWT (DEG F)44 LWT (DEG F)54 WATER FLOW (GPM)0.83 WATER PRESSURE DROP (FT PD) 2.6 EAT DB/WB (DEG F/DEG F)76 LAT DB/WB (DEG F/DEG F)55 ROWS 3 FINS PER INCH 12 AIR PRESSURE DROP (IN WC) 0.08 CONTROL VALVE TYPE 2-WAY PHYSICAL OPERATING WEIGHT (LBS) 80 DIMENSIONS FINS - L X W X H (IN X IN X IN) 12 X 12 X 4DIMENSIONS FLANGES- L X W X H (IN X IN X IN)15.5 X 16 X 6.125 COOLING COIL PIPING IN/OUT (IN/IN) 3/4 2. CONCRETE PAD OR CURB TO BE PROVIDED AND SHALL TERMINATE MINIMUM 12" ABOVE FINISH ROOF OR FLOOR ELEVATION 3. PROVIDE MASON SFDEJ (OR EQUIVELANT) AT UNIT PIPE CONNCTION 4. PROVIDE NEOPRENE WASHER GROMMET AT UNIT CONNECTION TO EQUIPMENT PAD (MASON HD WASHER BUSHING OR EQUIVALENT) VIBRATION ISOLATOR AND SEISMIC RESTRAINT DEVICE SCHEDULE EQUIPMENT DESCRIPTION TAG TYPE SERVICE MOUNTING VIBRATION ISOLATOR TYPE MINIMUM DEFLECTION (IN) BASE/CURB TYPE SEISMIC RESTRAINT DEVICE TYPE NOTES DEDICATED OUTDOOR AIR SYSTEM UNIT HEATER HWUH1-100 HOT WATER UNIT HEATER EQUIPMENT ROOM SUSPENDED MASON 30N 1.00 N/A CABLE RESTRAINT DOAS-R-01 DOAS VENTILATION AND AIR CONDITIONING FIRST FLOOR ROOF BY MANUFACTURER BY MANUFACTURER 12" CONCRETE PAD N/A SELECTED AND PROVIDED BY MANUFACTURER FAN COIL UNITS FCUX-XXX FAN COIL UNIT VARIES SUSPENDED MASON 30N 1.00 N/A CABLE RESTRAINT PROVIDE FLEX CONNECTION AT DUCT CONNECTION FANS MAIN AND MAINENANCE BUILDINGS XFX-XX IN-LINE CENTRIFUGAL HYDROTHERAPY SUSPENDED MASON HD 0.35 N/A CABLE RESTRAINT FAN POWERED VAV TERMINALS FTX-XXX VAV TERMINALS VARIES SUSPENDED MASON 30N 1.00 N/A CABLE RESTRAINT PROVIDE FLEX CONNECTION AT DUCT CONNECTION UNIT HEATER HWUH-1-100 VERTICAL LAUNDRY SUSPENDED MASON HD 0.35 N/A CABLE RESTRAINT NOTES: 1. FOR CATEGORY D, PER ASCE 7-10 CHP 13 SEISMIC DESIGN REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS 13.1.4 EXEMPTIONS, REQUIRES: A) IP = 1.0 OR LESS, B) POSITIVE ATTACHMENT TO STRUCTURE, AND C) FLEX CONNECTIONS AT COMPONENT WHERE ATTACHES TO DUCT, PIPING, CONDUIT, ETC. WATER HEATERS AND STORAGE TANKS EWH-2001 THRU EWH-2003 ELECTRIC VERTICAL DOMESTIC HOT WATER FLOOR NA NA N/A (2) 1-1/2" STRAPS PROVIDE AT 1/3 AND 2/3 HIGH STRAPSDHWST-2001 AND DHWST-2002 VERTICAL DOMESTIC HOT WATER FLOOR NA NA N/A (2) 1-1/2" STRAPS SEWH-01 ELECTRIC VERTICAL DOMESTIC HOT WATER FLOOR NA NA N/A (2) 1-1/2" STRAPS 1. VERIFY RIGHT OR LEFT HAND CONFIGURATION PRIOR TO PURCHASING. MINIMUM HEATING CFM 440 800 150 480 325 280 400 540 200 150 150 250 150 150 MINIMUM CFM 440 800 150 480 325 280 400 540 200 80 80 150 80 80 INLET PRESSURE (IN WC) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 SUMMER PRIMARY AIR TEMP (F) 60 60 60 60 60 60 60 60 60 55 60 60 60 60 WINTER PRIMARY AIR TEMP (F) 65 65 65 65 65 65 65 65 65 74 65 65 65 65 PHYSICAL DIMENSIONS LXWXH (IN) 15.5 X 12 X 8 15.5 X 14 X 13 15.5 X 12 X 8 15.5 X 12 X 10 15.5 X 12 X 8 15.5 X 12 X 8 15.5 X 12 X 8 15.5 X 12 X 10 15.5 X 12 X 10 15.5 X 12 X 8 15.5 X 12 X 8 15.5 X 12 X 10 15.5 X 12 X 8 15.5 X 12 X 8 WEIGHT (LB) ARRANGMENT NOTES 1 1 1 1 1 1 1 1 1 1 1 1 1 1 NOTES: PRESSURE INDEPENDENT PRIMARY AIR VAV TERMINAL SCHEDULE TAG VAV1-111 VAV1-112 VAV1-121 VAV1-122 VAV1-123 VAV1-124 VAV1-131 VAV1-141 VAV1-402 VAV1-403 VAV1-451 VAV1-501 VAV1-502 VAV1-503 AIR SYSTEM #DOAS DOAS DOAS DOAS DOAS DOAS DOAS DOAS DOAS AHU2001 AHU2001 DOAS DOAS DOAS TERMINAL UNIT TYPE SINGLE DUCT SUPPLY SINGLE DUCT SINGLE DUCT SINGLE DUCT LOCATION DOAS1VAV-F1 DOAS1VAV-E1 DOAS1VAV-E25 DOAS1VAV-E3 DOAS1VAV-F2 DOAS1VAV-E2 DOAS1VAV-D3 DOAS1VAVC-4 DOAS1VAVD-4 AHU20011VAVE-4 AHU20011VAVE-4 DOAS1VAVC55-5 DOAS1VAVD-5 DOAS1VAVE-5 SERVICE TRAINING 104 DEFIANCE/ACADEMY WEIGHT ROOM WOMEN LOCKER 108 STAFF LOCKER 109 DEFIANCE LOCKER 106 ACADEMY LOCKER 107 GROOMIMG 162 TEAM LOCKER 161 MEDICAL TRAINING 138 EQUIPMENT ROOM 155 EQUIPMENT ROOM 155 WEIGHT ROOM 137 MEDICAL AND PERFORMANCE 147 COACH LOCKER 152 EQUIPMENT MANUFACTURER TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS MODEL DESV DESV DESV DESV DESV DESV DESV DESV DESV DESV DESV DESV DESV DESV UNIT SIZE 06 10 06 07 06 06 06 07 08 06 06 08 06 05 INLET SIZE (IN)6 10 6 7 6 6 6 7 8 6 6 8 6 5 OUTLET SIZE (IN, WxH OR DIAMETER) 12 X 8 14 X 12.5 12 X 8 12 X 10 12 X 8 12 X 8 12 X 8 12 X 10 12 X 10 12 X 8 12 X 8 12 X 10 12 X 8 12 X 8 AIR VALVE PERFORMANCE MAXIMUM CFM 440 800 150 480 325 280 400 540 750 200 240 600 360 240 FPI 12 12 12 10 12 12 12 12 12 12 12 12 12 12 WATER PRESSURE DROP (FT) 0.08 0.14 0.08 0.05 0.27 0.23 0.45 0.83 0.18 0.08 0.08 0.31 0.08 0.08 AIR PRESSURE DROP (IN) 0.14 0.12 0.02 0.08 0.08 0.06 0.15 0.12 0.22 0.03 0.03 0.15 0.1 0.05 NC LEVEL RADIATED 21 20 10 20 17 15 21 22 22 13 13 20 18 17 DISCHARGE 25 23 18 25 23 25 25 25 27 22 22 28 24 31 HEATING COIL CAPACITY (BTUH) 7,260 13,200 2,475 7,920 5,363 4,620 6,600 8,910 3,300 1,815 2,475 4,125 2,475 2,475 EWT (F)150 150 150 150 150 150 150 150 150 150 150 150 150 150 LWT (F)135 135 135 135 135 135 135 135 135 135 135 135 135 135 GPM 1.0 1.8 0.3 1.1 0.7 0.6 0.9 1.2 0.4 0.3 0.3 0.6 0.3 0.3 WINTER EAT (F) 70 70 70 70 70 70 70 70 70 74 70 70 70 70 WINTER LAT (F) 85 85 85 85 85 85 85 85 85 85 85 85 85 85 NUMBER OF ROWS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT SUPPLY SINGLE DUCT © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:13:52 AM3/13/2023 9:13:52 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M101 MECHANICAL SCHEDULES 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE 50% DD 02/27/2023 FLUID TYPE WATER FLOW RATE (GPM)15.5 EWT (DEG-F)155 LWT (DEG-F)110 MAX. FLUID DP (FT)6.1 COIL VOLUME (GAL) CONNECTION SIZE (IN)1-1/2 CONNECTION TYPE ENERGY RECOVERY DOAS UNIT SCHEDULE TAG DOAS-R-01 LOCATION ROOF E-2 MANUFACTURER DUNHAM BUSH MODEL NO.SCS3HR TYPE ENTHALPY WHEEL AREAS SERVED LEVEL 1 SUPPLY FAN(S) AIRFLOW (CFM)6,000 ESP (IN) [1]3.5 TSP (IN) [2]6.5 PERCENT OUTDOOR AIR 100% FAN RPM 2399 DRIVE DIRECT FAN TYPE PLUG FAN QUANTITY X SIZE (IN)1 MOTOR TYPE NEMA PREMIUM MOTOR QUANTITY X HP 15 TOTAL BHP 9.97 VARIABLE SPEED DRIVES [3]VFD EXHAUST FAN(S) AIRFLOW (CFM)6,000 ESP (IN) [1]3.5 TSP (IN) [2]4.9 FAN RPM 2162 DRIVE DIRECT FAN TYPE PLUG FAN QUANTITY X SIZE (IN)1 MOTOR TYPE NEMA PREMIUM MOTOR QUANTITY X HP 10 TOTAL BHP 7.5 VARIABLE SPEED DRIVE [3]VFD HEAT RECOVERY WHEEL WHEEL TYPE ENTHALPY HEAT WHEEL QUANTITY 1 MOTOR HP PER WHEEL WHEEL DIAMETER (IN)55.12 MATERIAL TYPE ALUMINUM PURGE CYCLE NA BYPASS NO INLET AIRFLOW (CFM)6,000 EXHAUST AIRFLOW (CFM)6,000 TEMPERATURE EFFICIENCY (%)68 WINTER CONDITIONS: SUPPLY INLET EDB (F)24.0 SUPPLY INLET LDB (F)55.4 INLET PRESSURE DROP (IN WC)0.85 EXHAUST EDB/EWB (F)70 EXHAUST LDB/LWB (F)38 EXHAUST PRESSURE DROP (IN WC) 0.91 SUMMER CONDITIONS: CONNECTION TYPE HOT WATER COIL AIRFLOW (CFM)6,000 COIL SIZE (IN X IN)66 X 27.1 NUMBER OF ROWS 1 MAXIMUM FINS/INCH 12 MAX FACE VELOCITY (FPM)483 MAX AIR DP (IN WG)0.17 HEATING CAPACITY (MBH)303.8 COIL EAT DB/WB (F)55.4 COIL LAT DB/WB (F)100.5 SUPPLY INLET EDB (F)86 SUPPLY INLET LDB (F)75 INLET PRESSURE DROP (IN WC)0.91 EXHAUST EDB/EWB (F)70 EXHAUST LDB/LWB (F)81 EXHAUST PRESSURE DROP (IN WC) 0.85 CHILLED WATER COIL AIRFLOW (CFM)6,000 COIL SIZE (IN X IN)66 X 27.1 NUMBER OF ROWS 4 MAXIMUM FINS/INCH 10 MAX FACE VELOCITY (FPM)483 MAX AIR DP (IN WG)0.67 TOTAL COOLING (MBH)144.8 SENSIBLE COOLING (MBH)142.5 SENSIBLE COOLING RATIO COIL EAT DB/WB (F)75 COIL LAT DB/WB (F)52.6/52.5 FLUID TYPE WATER FLOW RATE (GPM)24 EWT (DEG-F)44 LWT (DEG-F)56 MAX. FLUID DP (FT)2.5 COIL VOLUME (GAL) CONNECTION SIZE (IN)1-1/2 ENERGY RECOVERY DOAS UNIT SCHEDULE (CONT.) FILTERS SUPPLY FILTERS TYPE RIGID MERV RATING 8 FILTER THICKNESS (IN)4 COLOR/ FINISH FACTORY CONVINIENT LIGHT (MARINE GRADE) YES NOTES: 1.EXTERNAL STATIC PRESSURE IS EXTERNAL TO THE UNIT AND DOES NOT INCLUDE AN ALLOWANCE FOR DIRTY FILTERS. 2.TOTAL STATIC PRESSURE SHALL INCLUDE INTERNAL COMPONENTS PLUS SCHEDULED ALLOWANCES FOR FILTER LOADING. 3.PROVIDE A VFD FOR EACH MOTOR. IF MULTIPLE VFDS, A COMMON SIGNAL SHALL PROVIDE VFD SPEED CONTROL. 4. PROVIDE SUPPLY AND EXHAUST AIRFLOW MEASURING STATION FOR LEED COMPLIANCE MAX FACE VELOCITY (FPM)500 DELTA-P CLEAN (IN WG)0.3 DELTA-P DIRTY (IN WG)0.4 REPLACEMENT SETS 0.0 SIZE AND QUANTITY (3) 24X24 SUPPLY FILTERS TYPE RIGID MERV RATING 13 FILTER THICKNESS (IN)2 MAX FACE VELOCITY (FPM)500 DELTA-P CLEAN (IN WG)0.3 DELTA-P DIRTY (IN WG)0.4 REPLACEMENT SETS 0.0 SIZE AND QUANTITY (3) 24X24 EXHAUST FILTERS TYPE DISPOSABLE MERV RATING 13 FILTER THICKNESS (IN)2 MAX FACE VELOCITY (FPM)500 DELTA-P CLEAN (IN WG)0.3 DELTA-P DIRTY (IN WG)0.4 REPLACEMENT SETS 0.0 SOUND DATA BY OCTAVE BAND BARE SUPPLY FAN 63 HZ INLET/OUTLET (DB)51.7/47.8 125 HZ INLET/OUTLET (DB)54.9/51.1 250 HZ INLET/OUTLET (DB)71.7/68.4 500 HZ INLET/OUTLET (DB)74.7/70.8 1000 HZ INLET/OUTLET (DB)77.1/73.4 2000 HZ INLET/OUTLET (DB)72/68.5 4000 HZ INLET/OUTLET (DB)65.5/61.8 8000 HZ INLET/OUTLET (DB)59.4/55.6 BARE EXHAUST FAN 63 HZ INLET/OUTLET (DB)56.2/59 125 HZ INLET/OUTLET (DB)62.6/65.5 250 HZ INLET/OUTLET (DB)77.7/81.1 500 HZ INLET/OUTLET (DB)80.7/83.5 1000 HZ INLET/OUTLET (DB)82.2/85.2 2000 HZ INLET/OUTLET (DB)77.3/80.5 4000 HZ INLET/OUTLET (DB)71.6/74.6 8000 HZ INLET/OUTLET (DB)65.3/68.2 TOTAL FOR SUPPLY AND EXHAUST FANS 63 HZ SUPPLY/EXHAUST (DB)49.5/46.2 125 HZ SUPPLY/EXHAUST (DB)38.9/38.8 250 HZ SUPPLY/EXHAUST (DB)57.4/55.6 500 HZ SUPPLY/EXHAUST (DB)59.1/57.3 1000 HZ SUPPLY/EXHAUST (DB)64.5/61.8 2000 HZ SUPPLY/EXHAUST (DB)55.5/53 4000 HZ SUPPLY/EXHAUST (DB)40.4/38.7 8000 HZ SUPPLY/EXHAUST (DB)33.6/31.7 ELECTRICAL DATA POINT OF CONNECTION SINGLE VOLT/PHASE 460/3 DISCONNECT PROVIDED (MC/ EC)FACTORY INSTALLED (MC/ EC)FACTORY SUPPLY FAN POWER NORMAL EXHAUST FAN POWER NORMAL MOP (AMPS) - FAN SECTION 60 MCA (AMPS) - FAN SECTION 35 ETL LISTED YES PANEL SCCR (KA)5 PHYSICAL DATA LENGTH (IN) 171.26 WIDTH (IN) 80.71 HEIGHT (IN)88.59 OPERATING WEIGHT (LBS) CONTROLS - REFERENCE ONLY NORMAL MODE DDC CONTROLS BY CONTROL CONTRACTOR ACCESSORIES FANS - INTERNAL SPRING ISOLATORS YES UNIT - EXTERNAL ISOLATION YES INVERTER DUTY MOTORS NA SMOKE DETECTOR YES BY EC 'FURNISH/INSTALL/WIRE EC/EC CONTROLS CONTROL CONTRACTOR INTERNAL ACCESS LADDER NA AIRFLOW MEASURING STATION NA PURGE SECTOR NA 2. SMOKE DETECTOR IF REQUIRED: FURNISHED AND WIRED BY DIVISION 26, INSTALLED IN DUCT BY DIVISION 23. 3. UNIT TO BE INTERLOCKED WITH GARAGE DOOR 4. FIELD VERIFY RIGHT OR LEFT CONFIGURATION PRIOR TO PURCHASING. FIRST FLOOR SERIES FAN TERMINAL SCHEDULE TAG FT1-701 FT1-100 FT1-704 FT1-201 FT1-251 FT1-301 FT1-302 FT1-351 FT1-351A FT1-451 FT1-501 FT1-452 AIR SYSTEM #AHU-2004 AHU2001 AHU2004 AHU2001 AHU2001 AHU1001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 TYPE SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV LOCATION 20041FTE-1 20011FTE-15 20041FTE-15 20011FTD-2 20011FTE-25 20011FTE-3 20011FTD-3 20011FTC-4 20011FTC-4 20011FTE-45 20011FTB-5 20011FTF-45 SERVICE ENTRY LOBBY 101 CLASSROOM 103 ENTRY LOBBY 101 COACHES WORKPLACE 112 3RD PARTY 117 STUDIO 115 TEAM LECTURE 118 INTER CONT 119 WORKS 121/122 ADMIN WORK 120 BOOT CL 134 HEAD PER 139 BOOT CL 134 HEAD PER 139 PLAYER LOUNGE 136 PLAYER LOUNGE 136 COACH WORK 150 EQUIPMENT MANUFACTURER TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS NC LEVEL RADIATED DISCHARGE ACCESSORIES ACTUATOR FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY CONTROL CARD FURNISH/INSTALL FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY CONTROL TRANSFORMER FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY MODEL DTFC DTFC DTFC DTFQ 2 DTFQ 3 DTFQ 3 DTFQ 4 DTFQ 3 DTFQ 3 DTFQ 3 DTFQ 3 DTFC UNIT SIZE C B D12 A A C OUTLET COLLAR SIZE (IN) T.I.YES YES YES YES YES YES YES YES YES YES YES YES INSTALLATION TYPE ACT ACT ACT ACT ACT ACT ACT GWB GWB GWB GWB ACT INLET SIZE (IN) 12 8 12 8 6 8 8 6 6 8 10 12 DISCHARGE PLENUM SIZE (IN) DIMENSIONS (IN) INSULATION TYPE ECM MOTOR YES YES YES YES YES YES YES YES YES YES YES YES SINGLE POINT POWER YES YES YES YES YES YES YES YES YES YES YES YES SMOKE DETECTOR NO NO NO NO NO NO NO NO NO NO NO NO FILTERS (MERV) 8 8 8 8 8 8 8 8 8 8 8 8 4 4 4 4 4 4 4 4 4 4 4 4 NOTES: NOTES: 1. FURNISH WITH FACTORY-PROVIDED ACTUATOR AND DDC CONTROL FOR PRESSURE INDEPENDENT OPERATION FINS PER INCH NA NA NA NA NA NA NA AIR PRESSURE DROP (IN)NA NA NA NA NA NA NA CONTROL VALVE TYPE 2-WAY 2-WAY 2-WAY 2-WAY 2-WAY FAN ELECTRICAL VOLT/PHASE 277/1 277/1 277/1 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/1 277/1 POWER (HP) DISCONNECT YES YES YES YES YES YES YES YES YES YES YES YES FURNISHED/INSTALLED MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC PERFORMANCE MAX FAN AIRFLOW (CFM) 1,200 740 1,300 800 400 850 850 160 400 520 860 1,200 MIN FAN AIRFLOW (CFM) 200 400 200 350 200 400 400 100 150 200 400 200 MIN PRIMARY AIRFLOW (CFM) 130 200 130 200 100 200 200 60 80 100 150 130 INLET PRESSURE (IN W.C.) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 SUPPLY AIR TEMP SUMMER (F) 55 55 55 55 55 55 55 55 55 55 55 55 SUPPLY AIR TEMP WINTER (F) 74 74 74 74 74 74 74 74 74 74 74 74 HEATING COIL TOTAL CAPACITY (BTUH) 14.32 8.83 15.52 NA NA NA NA NA NA NA 10.26 14.32 EWT (F)155 155 155 NA NA NA NA NA NA NA 155 155 LWT (F)135 135 135 NA NA NA NA NA NA NA 135 135 WATER FLOW (GPM) 0.0 0.0 0.0 NA NA NA NA NA NA NA 0.0 0.0 WATER PRESSURE DROP (FT)NA NA NA NA NA NA NA EAT (F)74 74 74 NA NA NA NA NA NA NA 74 74 LAT (F)85 85 85 NA NA NA NA NA NA NA 85 85 NUMBER OF ROWS NA NA NA NA NA NA NA WATER PRESSURE DROP (FT)NA NA NA NA NA NA NA 2. SMOKE DETECTOR IF REQUIRED: FURNISHED AND WIRED BY DIVISION 26, INSTALLED IN DUCT BY DIVISION 23. 3. UNIT TO BE INTERLOCKED WITH GARAGE DOOR 4. FIELD VERIFY RIGHT OR LEFT CONFIGURATION PRIOR TO PURCHASING. FURNISHED/INSTALLED MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC MC/EC NC LEVEL RADIATED DISCHARGE ACCESSORIES ACTUATOR BY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY CONTROL CARD FURNISH/INSTALL FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FINS PER INCH NA NA NA NA NA NA NA NA NA NA NA NA AIR PRESSURE DROP (IN WC) NA NA NA NA NA NA NA NA NA NA NA NA CONTROL VALVE TYPE NA NA NA NA NA 2-WAY NA NA NA 2-WAY 2-WAY 2-WAY NA NA 2-WAY NA 2-WAY NA FAN ELECTRICAL VOLT/PHASE 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 277/3 POWER (HP) DISCONNECT YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES MODEL DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS DTFS UNIT SIZE B B C B A A C C C D D A A A B D C B INLET SIZE (IN)8 6 10 6 6 6 12 12 12 12 12 6 6 6 8 12 10 8 OUTLET COLLAR SIZE (IN) 14.125"x11.125" 14.125"x11.125" 14.125"x11.125" 14.125"x11.125" 7"x7" 18.5"x10" 14.125"x11.125" 14.125"x11.125" 14.125"x11.125" 25"x17.5" 25"x17.5" 18.5"x10" 7"x7" 7"x7" 20.5"x12.5" 16.5"x14.625" 20.5"x12.5" 14.125"x11.125" T.I.YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES INSTALLATION TYPE GWB GWB GWB ACT ACT ACT GWB GWB GWB GWB GWB GWB GWB GWB GWB OTS ACT ACT DISCHARGE PLENUM SIZE (IN) DIMENTIONS (W x L x H) PERFORMANCE MAX FAN AIRFLOW (CFM) 550 500 1030 450 150 400 800 800 800 1,600 1,200 310 170 130 570 1,260 1,020 500 MIN FAN AIRFLOW (CFM) 250 200 310 150 80 200 500 250 250 400 500 20 100 60 200 270 400 200 MIN PRIMARY AIRFLOW (CFM) 150 150 200 100 80 150 300 150 150 200 200 20 80 60 120 150 200 150 INLET PRESSURE (IN W.C.) 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 SUPPLY AIR TEMP SUMMER (F) 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 SUPPLY AIR TEMP WINTER (F) 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 SECOND FLOOR SERIES FAN TERMINAL SCHEDULE TAG FT2-302 FT2-301 FT2-201 FT2-403 FT2-507 FT2-604 FT2-402 FT2-505 FT2-506 FT2-603 FT2-602 FT2-601 FT2-504 FT2-503 FT2-501 FT2-401 FT2-502 FT2-202 AIR SYSTEM #AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 AHU2001 TYPE SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV SERIES FPVAV LOCATION 20012FT-C3 20012FT-C3 20012FT-D25 20012FT-D4 20012FT-D55 20012FT-D6 20012FT-C4 20012FT-C5 20012FT-C5 20012FT-C6 20012FT-B6 20012FT-A57 20012FT-A55 20012FT-B5 20012FT-A5 20012FT-B4 20012FT-B4 20012FT-E25 SERVICE CONFERENCE 203 LARGE CONFERENCE 205 OPEN WORK 206 OFFICES 207/208/209/210 OFFICES 211/212 CONFERENCE 213 OPEN WORK 214 OPEN WORK 214 OPEN WORK 214 OPEN WORK 214 SOCCER OPS WORKSPACE 216 SOCCER SVP 218 WAR ROOM 219 OWNER 220 RAVE GREEN LOUNGE 221 CAFE/BREAK 222 CAFE/BREAK 222 OFFICES 227/228/229/230 EQUIPMENT MANUFACTURER TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS TITUS CONTROL TRANSFORMER FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY FACTORY INSULATION TYPE ECM MOTOR YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES SINGLE POINT POWER YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES SMOKE DETECTOR NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO FILTERS (MERV)8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 3, 4 4 NOTES: 1. FURNISH WITH FACTORY-PROVIDED ACTUATOR AND DDC CONTROL FOR PRESSURE INDEPENDENT OPERATION HEATING WATER COIL TOTAL HEATING (MBH) NA NA NA NA NA 4.84 NA NA NA 19.36 14.52 28.99 NA NA 6.90 NA 12.34 NA EWT (DEG F)NA NA NA NA NA 155 NA NA NA 155 155 155 NA NA 155 NA 155 NA LWT (DEG F)NA NA NA NA NA 135 NA NA NA 135 135 135 NA NA 135 NA 135 NA WATER FLOW (GPM) NA NA NA NA NA 0.48 NA NA NA 1.94 1.45 2.90 NA NA 0.69 NA 1.23 NA WATER PRESSURE DROP (FT PD) NA NA NA NA NA NA NA NA NA NA NA NA EAT (DEG F)NA NA NA NA NA 74 NA NA NA 74 74 74 NA NA 74 NA 74 NA LAT (DEG F)NA NA NA NA NA 85 NA NA NA 85 85 85 NA NA 85 NA 85 NA NUMBER OF ROWS NA NA NA NA NA NA NA NA NA NA NA NA © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:13:57 AM3/13/2023 9:13:57 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M102 MECHANICAL SCHEDULES 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE 50% DD 02/27/2023 ELECTRIC HEAT TRACE SCHEDULE TAG HT-1 (FOR REFERANCE ONLY)HT-2 SERVICE [2] [1] LOCATION PER PLAN PER PLAN EQUIPMENT MANUFACTURER RAYCHEM RAYCHEM MODEL 5XL2-CT 5XL2-CT NOTES: 1. HEAT TRACE AS INDICATED ON PLANS OF MAINTENANCE SHED 2. HEAT TRACE AT CHILLED AND HOT WATER PIPES BETWEEN DOAS AND BUILDING. PERFORMANCE WATTS/FT 5 5 ELECTRICAL VOLT 277 277 PHASE 1 1 POWER NORMAL NORMAL PHYSICAL PIPE SIZE (IN)PER PLAN PER PLAN INSULATION THICKNESS (IN) PER SCHEDULE PER SCHEDULE ACCESSORIES LINE SENSING THERMO. CONTROL -- -- POWER CONNECTION MULTIPLE POINT MULTIPLE POINT END SEAL -- -- ELECTRIC TRACED PIPE LABELS -- -- NOTES 1 1 FIRE SMOKE DAMPERS NOTES: 1. PROVIDE TRANSITIONS TO DUCT SIZE INDICATED ON PLANS IF DUCT SIZE DIFFERS FROM SCHEDULED DAMPER. FIRST FLOOR DOAS-1-R-01 SUPPLY FSD-1-101 FIRE SMOKE RUSKIN FSD60FA - YES CLASS 1 1.5 4000 8 AIRFOIL 120V 2-POS STAND-BY POWER FIRST FLOOR DOAS-1-R-01 EXHAUST FSD-1-102 FIRE SMOKE RUSKIN FSD60FA -YES CLASS 1 1.5 4000 8 AIRFOIL 120V 2-POS STAND-BY POWER FIRST FLOOR DOAS-1-R-01 RETURN FSD-2001 FIRE SMOKE RUSKIN FSD60FA - YES CLASS 1 1.5 4000 8 AIRFOIL 120V 2-POS STAND-BY POWER REPLACEMENT OF EXISTING DAMPER SCHEDULE FLOOR LOCATION SYSTEM DAMPER ID DAMPER TYPE MAKE MODEL SIZE [1]FACTORY END- SWITCH LEAKAGE RATING DUTY/RATING MAX VELOCITY (FPM) MAX PRESSURE (IN. H2O) BLADES Actuator Model POWER TYPE CONTROL BY - REFERENCE ONLY CONTROL NORMAL MODE - REFERENCE ONLY APPLICATION TYPE NOTES BACKDRAFT DAMPERS 1 HYDROTHERAPY RETURN AIR BDD-1-01 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 2000 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER 1 LAUNDRY OUTSIDE AIR BDD-1-02 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 2000 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER MOTORIZED DAMPERS FIRST FLOOR EF-1-100 EXHAUST MOD-1-100 MOTORIZED RUSKIN CD60 - YES CLASS 1A HEAVY 2000 2 AIRFOIL 120V BAS AUTO ENVELOPE DAMPER INTERLOCK DAMPER WITH EF ROOF DOAS-1-R-01 SUPPLY MOD-R-100 MOTORIZED RUSKIN CD60 - YES CLASS 1A HEAVY 2000 2 AIRFOIL 120V BAS AUTO ENVELOPE DAMPER INTERLOCK DAMPER WITH DOAS ROOF DOAS-1-R-01 EXHAUST MOD-R-101 MOTORIZED RUSKIN CD60 -YES CLASS 1A HEAVY 2000 2 AIRFOIL 120V BAS AUTO ENVELOPE DAMPER INTERLOCK DAMPER WITH DOAS 1 MAINTENANCE SHED EXHAUST SBDD-02 MOTORIZED RUSKIN CD60 -YES CLASS 1A HEAVY 2000 2 AIRFOIL 120V STAND ALONE AUTO ENVELOPE DAMPER 3. PROVIDE WITH 1/2"x0.063" EXPANDED METAL BIRD SCREEN EQUIPMENT MANUFACTURER RUSKIN RUSKIN RUSKIN MODEL ELF6375DX ELF6375DX ELF6375DX LOUVER SCHEDULE TAG L1-100 L1-101 L-02 SERVICE DRYER EXHAUST HYDROTHERAPY EXHAUST EXHAUST LOCATION SOUTH WALL SOUTH WALL SOUTH WALL NOTES 1, 2, 3 1, 2, 3 1, 2, 3 NOTES: 1. PROVIDED BY MECHANICAL CONTRACTOR 2. WATER PROOFING BY GENERAL CONTRACTOR; SEE ARCHITECTURAL PLANS FOR DETAILS FREE AREA (SQ. FT) 2.7 0.9 2.0 QUANTITY OF ACTIVE SECTIONS 1 1 1 PERFORMANCE PHYSICAL LOUVER DIMENSIONS W (IN) 48 16 36 LOUVER DIMENSIONS H (IN) 16 16 16 AIRFLOW (CFM)2,400 300 2,400 VELOCITY (FPM)900 338 1,200 PRESSURE DROP (IN WG) 0.02 0.02 0.02 3. INDOOR UNIT POWERED VIA OUTDOOR UNIT, FIELD INSTALLED POWER WIRING, USE 14 GAUGE WIRE. 4. AIRSIDE ECONOMIZERS ARE NOT REQUIRED AS THIS EQUIPMENT SHALL COMPLY WITH WSEC C403.3 EXCEPTION 10 OPTION A AND C406.2.2 MAINTENANCE SHED SPLIT-SYSTEM AIR-COOLED HEAT PUMP SCHEDULE TAG AC-01 INDOOR CU-01 OUTDOOR SERVICE MAINTENANCE SHED IDF ROOM LOCATION ROOF (CU), IDF ROOM (AC) EQUIPMENT MANUFACTURER SAMSUNG FAN COIL INDOOR MODEL AC018BNADCH/AA CONDENSING UNIT OUTDOOR MODEL AC018BXADCH/AA EFFICIENCY SEER (1) (4)19.1 MIN WSEC SEER 13.0 NOMINAL TONS COOLING 1.5 HEATING HSPF (2)10 MIN WSEC HSPF 7.7 REFRIGERANT R410A OUTDOOR UNIT COOLING OPERATING RANGE (DEG F)0 - 115 OUTDOOR UNIT HEATING OPERATING RANGE (DEG F)-4 - 76 SUPPLY FAN CFM 540 ESP N/A COOLING PERFORMANCE TOTAL MBH (1)18 SENS MBH 15.3 HEATING PERFORMANCE MBH (2)28 CONDENSING UNIT COMPRESSOR TYPE INVERTER-DRIVEN TWIN ROTARY STAGES VARIABLE OUTDOOR UNIT MOP 25 OUTDOOR UNIT MCA 18.4 RLA 12.7 VOLT/PHASE 208/1 POWER NORMAL DISCONNECT BY EC MOUNTING GROUND - CONCRETE PAD SOUND PRESSURE (dBA)48 FAN COIL FLA POWER (AMPS)0.42 INDOOR UNIT MCA -- VAPOR LINE (IN)1/2 MAX PIPE LENGTH (FT)19.1 MAX PIPE ELEVATION CHANGE (FT)98.4 MAXIMUM BENDS -- CONTROLS - REFERENCE ONLY NORMAL MODE AUTO CONTROLS BY STANDALONE ACCESSORIES 1" THROWAWAYFILTERS -- VOLT/PHASE 208/1 (3) MOUNTING HIGH WALL SOUND PRESSURE (dBA)38 PHYSICAL FAN COIL WEIGHT (LBS)27.8 FAN COIL DIMENSIONS W X D X H (IN X IN X IN)41-9/19 x 8-7/16 x 11-3/4 CONDENSATE DRAIN PIPE SIZE (IN)1 CONDENSER WEIGHT (LBS)118.4 CONDENSER DIMENSIONS W X D X H (IN X IN X IN)34-5/8 x 31-7/16 x 12-1/4 LIQUID LINE (IN)1/4 VIBRATION ISOLATORS SEE ISOLATOR SCHEDULE SIMPLE MA CONTROLLER YES LOW AMBIENT KIT TO 0 F -- CONDENSATE PUMP ASSEMBLY YES WIND BAFFLE YES CONDENSATE SENSOR UNIT INTERFACE NOTES:4 xxxx-split system-air cooled.x2a NOTES: 1. FOR COOLING, RATINGS AT INDOOR CONDITIONS OF 80/67 F DB/WB, OUTDOOR CONDITIONS OF 95/75 F DB/WB. 2. FOR HEATING, RATINGS AT INDOOR CONDITIONS OF 70/60 F DB/WB, OUTDOOR CONDITIONS OF 47/43 F DB/WB. NOTES: 1. RECESSED WALL INSTALLATION 2. PROVIDE WITH OPTIONAL MOUNTING BRACKET MAINTANCE SHED ELECTRIC UNIT HEATER SCHEDULE TAG EH-01 EH-02 EH-03 SERVICE PESTICIDE RESTROOM STORAGE LOCATION MAINTENANCE SHED MAINTENANCE SHED MAINTENANCE SHED EQUIPMENT MANUFACTURER QMARK QMARK QMARK MODEL MUH0541 AWH4307F MUH0541 HEATING PERFORMANCE BTU/HR 17,065 10,235 17,065 INPUT KW 5 3 5 STEPS -- -- -- ELECTRICAL AMPS 18 10.8 18 VOLT 480 277 480 PHASE 3 1 3 CONTROLS - REFERENCE ONLY NORMAL MODE AUTO AUTO AUTO CONTROLS BY STANDALONE STANDALONE STANDALONE PHYSICAL WEIGHT (LBS) 27 22 27 LENGTH (IN) 7-1/2 5 7-1/2 WIDTH (IN)14 15-3/4 14 HEIGHT (IN) 16 19-5/16 16 NOTES:2 1 2 xxxx-heater-electric unit.x2a POWER NORMAL NORMAL NORMAL STARTER FACTORY MTD FACTORY MTD FACTORY MTD --FURNISHED/INSTALLED MC/EC MC/EC MC/EC DISCONNECT BY EC BY EC BY EC --FURNISHED/INSTALLED EC/EC EC/EC EC/EC MOTOR GUARD NA NA NA NOTES 1 1 1 NOTES: [1] FAN MOTORS MUST MEET 2018 WSEC MINIMUM EFFICIENCIES. MAINTENANCE SHED EXHAUST FAN SCHEDULE TAG SEF-01 SEF-02 SEF-03 SERVICE PESTICIDE ROOM RESTROOM EQUIPMENT ROOM LOCATION MAINTENANCE SHED MAINTENANCE SHED MAINTENANCE SHED EQUIPMENT MANUFACTURER GREENHECK GREENHECK GREENHECK MODEL SQ-70 SQ-60 BSQ-240 FAN TYPE INLINE INLINE INLINE DRIVE DIRECT DIRECT BELT WHEEL TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL WHEEL DIAMETER (IN) PERFORMANCE CFM 170 100 3,300 ESP 0.25 0.25 0.25 RPM 1550 1550 446 ELECTRICAL BHP 0.03 0.02 0.3 HP 1/30 1/40 1/2 CONTROLS - REF ONLY NORMAL MODE AUTO AUTO AUTO CONTROL BY CONTINUOUS OPERATION CONTINUOUS OPERATION STAND ALONE PHYSICAL WEIGHT (LBS) 34 34 219 DISCHARGE POSITION HORIZONTAL HORIZONTAL HORIZONTAL VOLT/PHASE 115/1 115/1 115/1 POWER NORMAL NORMAL NORMAL STARTER EC MOTOR EC MOTOR --FURNISHED/INSTALLED MC/EC MC/EC MC/EC DISCONNECT BY EC BY EC BY EC --FURNISHED/INSTALLED EC/EC EC/EC EC/EC ARR. SIZE W X L X H (IN) 14X15X14 12X13X12 38X34X54 ACCESSORIES SPEED CONTROL EC EC EC VIBRATION ISOLATORS PER SCHEDULE PER SCHEDULE PER SCHEDULE BACKDRAFT DAMPERS NA NA X 1. PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR 2. WATER PROOFING BY GENERAL CONTRACTOR; SEE ARCHITECTURAL PLANS FOR DETAILS 3. PROVIDE WITH 1/2"x0.063" EXPANDED METAL BIRD SCREEN MAINTENANCE SHED LOUVER SCHEDULE TAG SL-01 SL-02 SL-03 SERVICE PESTICIDE ROOM STORAGE RESTROOM LOCATION MAINTENANCE SHED MAINTENANCE SHED MAINTENANCE SHED NOTES 1, 2, 3 1, 2, 3 1, 2, 3 NOTES: EQUIPMENT MANUFACTURER RUSKIN RUSKIN RUSKIN MODEL ELF6375 ELF6375 ELF6375 PHYSICAL TOTAL OPENING DIMENSION (H; in) 12 12 12 TOTAL OPENING DIMENSION (W; in) 12 12 12 FREE AREA/ ACTIVE SECTION (SQ. FT) 0.31 0.31 0.31 QUANTITY OF ACTIVE SECTIONS 1 1 1 ACTIVE FREE AREA (SQ. FT) 0.31 0.31 0.31 PERFORMANCE AIRFLOW (CFM)170 100 100 VELOCITY (FPM) 548 323 323 PRESSURE DROP (IN WG) 0.05 0.02 0.015 SECTION DIMENSIONS (H; in) 12 12 12 SECTION DIMENSIONS (W; in) 12 12 12 ACTIVE DIMENSIONS (W; in) [1] 12 12 12 ACTIVE DIMENSIONS (H; in) [1] 12 12 12 EQUIPMENT MANUFACTURER RUSKIN RUSKIN RUSKIN MODEL ELF6375 ELF6375 ELF6375 MAINTENANCE SHED LOUVER SCHEDULE TAG SL-01 SL-02 SL-03 SERVICE PESTICIDE ROOM STORAGE RESTROOM LOCATION MAINTENANCE SHED MAINTENANCE SHED MAINTENANCE SHED 1. PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR 2. WATER PROOFING BY GENERAL CONTRACTOR; SEE ARCHITECTURAL PLANS FOR DETAILS 3. PROVIDE WITH 1/2"x0.063" EXPANDED METAL BIRD SCREEN PHYSICAL TOTAL OPENING DIMENSION (H; in) 12 12 12 TOTAL OPENING DIMENSION (W; in) 12 12 12 NOTES 1, 2, 3 1, 2, 3 1, 2, 3 NOTES: FREE AREA/ ACTIVE SECTION (SQ. FT) 0.31 0.31 0.31 QUANTITY OF ACTIVE SECTIONS 1 1 1 ACTIVE FREE AREA (SQ. FT) 0.31 0.31 0.31 PERFORMANCE AIRFLOW (CFM)170 100 100 VELOCITY (FPM) 548 323 323 PRESSURE DROP (IN WG) 0.05 0.02 0.015 SECTION DIMENSIONS (H; in) 12 12 12 SECTION DIMENSIONS (W; in) 12 12 12 ACTIVE DIMENSIONS (W; in) [1] 12 12 12 ACTIVE DIMENSIONS (H; in) [1] 12 12 12 4. PROVIDE OPPOSED BLADE DAMPER AT ELEVATOR LOBBY SUPPLY GRILLES N1 FLOWBAR - HIGH THROW Price Industries AS-10 1-SLOT ALUMINUM SURFACE Border 22C PER PLAN X 3.75" WIDE 8 190 8 22 WHITE 6 NOTES: 1. PROVIDE PLENUM CAN FOR DUCTED SYSTEM IN CEILING APPLICATION (NOT REQUIRED FOR SIDEWALL APPLICATION); OR PROVIDE SOUND BOOT AS INDICATED ON PLANS. 2. DIFFUSER OR GRILLE MAY ALSO BE USED FOR HARDLID APPLICATIONS WHERE A PRICE "APF" MOUNT FRAME IS PROVIDED, FRAME AS INDICATED ON PLANS. APF PROVIDES ACCESS ABOVE CEILING. 3. FOR LIMITED CEILING HEIGHT APPLICATIONS, PROVIDE PLENUM CAN WITH BRANCH DUCT SIZED SIDE INLET, OTHERWISE PROVIDE SQUARE TO ROUND TRANSITION WITH BRANCH DUCT SIZED TOP INLET. G1 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 10X10 8X8 275 PER PLAN 19 WHITE 1. 4 G2 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 12X12 10X10 360 PER PLAN 16 WHITE 1. 4 G3 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 14X14 12X12 540 PER PLAN 18 WHITE 1. 4 G4 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 16X16 14X14 710 PER PLAN 19 WHITE 1. 4 G5 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 30X16 28X14 1220 PER PLAN 17 WHITE 1. 4 C1 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM LAY-IN BORDER TYPE 3 24x12 22X10 600 PER PLAN <12 WHITE 1, 2 C2 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM LAY-IN BORDER TYPE 3 24x24 22X22 1200 PER PLAN <12 WHITE 1, 2 C3 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM LAY-IN BORDER TYPE 3 24x48 22X46 2400 PER PLAN <12 WHITE 1, 3 C4 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 1 26x14 24x12 600 PER PLAN <12 WHITE 1 C5 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 1 52x48 50x46 11000 PER PLAN 27 WHITE 1 C6 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 1 22x20 20x18 700 PER PLAN <12 WHITE 1 E1 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 10X10 8X8 100 6 <10 WHITE 1 E2 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 12X12 10X10 210 8 <10 WHITE 1 E3 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 14X12 12X10 275 PER PLAN 17 WHITE 1 E4 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 14X14 12X12 375 10 10 WHITE 1 E5 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 16X16 14X14 550 12 27 WHITE 1 E6 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 20X16 18X14 800 PER PLAN 14 WHITE 1 E7 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 20X18 18X16 910 PER PLAN 14 WHITE 1 E8 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 26X14 24X12 910 PER PLAN 14 WHITE 1 E9 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 32X16 30X14 1112 PER PLAN 21 WHITE 1 E10 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 86X20 84X18 -- PER PLAN -- WHITE 1 GRILLE, REGISTER AND DIFFUSER SCHEDULE EQUIP. SERVICE MANUFACTURER MODEL DESCRIPTION ID NO.STYLE MATERIAL FRAME FRAME MODEL FACE SIZE NECK SIZE MAX CFM BRANCH DUCT NC COLOR NOTES A1 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 8X8 100 6 <15 WHITE 2, 3 A2 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 10X10 210 8 <15 WHITE 3, 5 A3 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 12X12 375 10 <15 WHITE 3, 5 A4 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 14X14 550 12 18 WHITE 2, 3 A5 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 16X16 700 14 19 WHITE 3, 5 B1 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 13-9/16x13-916 8X8 100 6 <15 WHITE 5 B2 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 15-9/16x15-9/16 10X10 210 8 <15 WHITE 5 B3 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 17-9/16x17-9/16 12X12 375 10 <15 WHITE 5 B4 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 19-9/16x19-9/16 14X14 550 12 18 WHITE 5 B5 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 22X22 16X16 700 14 19 WHITE 5 NOTES: MODEL HCH 104 CABINET STYLE CABINET INSULATION TYPE CABINET INSULATION THICKNESS (IN) MOUNTING SUSPENDED SUPPLY FAN MAX FAN AIRFLOW (CFM) 1,830 HOT WATER UNIT HEATER SCHEDULE TAG HWUH1-100 SYSTEM AHU2001 SERVICE 20011UHF-4 LOCATION EQUIPMENT 155 EQUIPMENT MANUFACTURER MODINE ESP @ MAX (IN WC) (1) 0 SPEED (RPM)1,075 DRIVE TYPE DIRECT FAN ISOLATION TYPE SEE SCHEDULE MAXIMUM MOUNTING HEIGHT (FT) 11 HEATING WATER COIL TOTAL HEATING (MBH) 108.24 OPERATING WEIGHT (LBS) 93 DIMENSIONS - L X W X H (IN X IN X IN) 26.5 X 26.5 X 18.2 HEATING COIL PIPING IN/OUT (IN/IN) 3/4 ACCESSORIES NOTES FLA MCA MOCP STARTER BY EC DISCONNECT BY EC SCCR NA PHYSICAL EWT (DEG F)155 LWT (DEG F)135 WATER FLOW (GPM) 10.82 WATER PRESSURE DROP (FT PD) 4.80 EAT (DEG F)24 LAT (DEG F)65 ROWS NA FINS PER INCH NA AIR PRESSURE DROP (IN WC) NA CONTROL VALVE TYPE 2-WAY ELECTRICAL MOTOR TYPE EC MOTOR HP 1/6 POWER NORMAL VOLTS/PHASE 120/1 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:02 AM3/13/2023 9:14:02 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M103 MECHANICAL SCHEDULES 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE 50% DD 02/27/2023 NOTES:1 - Copper - Use "Branch Takeoff" in lieu of fitting if branch piping is 1 sizes less than main or more. Example; Use 1-1/2" T-Drill in lieu of 2"x1-1/2" Tee. 2 - Carbon Steel - Use "Branch Takeoff" in lieu of fitting if branch piping is 2 sizes less than main or more. Example; Use 2-1/2" shaped nipple (saddle) in lieu of 4"x2-1/2" Tee. 3 - Contractor discretion to use other joint types for means and methods in small amount, for a complete system Condensate Drain ITEMS 2" And Smaller 2-1/2" Through 30" PIPE MATERIALS Pipe, Copper Type L B88 Pipe, Sch 40 Blk A53B ERW (Up to 10"), Pipe, Std Wt Blk A53B ERW (12" And Larger) JOINT TYPE Swt - Lead-Free Solder, Silvabrite 100 BW FITTING MATERIAL Wrot Copper B16.22 Std Wt A234 WPB B16.9 BALL VALVES: 150# Ball Valve, Two-Piece Full Port SP-110 Brnz Swt - Milwaukee BA-450 N/A GATE VALVES: N/A 125# Gate Valve, Bolted Bonnet OS&Y Solid Wedge SP-70 CI Flg - Milwaukee F2885M GLOBE VALVES: 125# Globe Valve, Screw-In Bonnet Integral Seat SP-80 Brnz Swt - Milwaukee 1502 125# Globe Valve, Bolted Bonnet SP-85 CI Flg - Milwaukee F2981M STRAINER, Y-PATTERN 125# Strainer, Y-Pattern Brnz Thd - Mueller 351M 125# Strainer, Y-Pattern CI Flg - Mueller 758 PRESSURE GAUGE 0-100# Pressure Gauge, Aluminum Case, Brnz Thd - Weiss 4PG-N1 Pressure Gauge, Aluminum Case, Brnz Thd - Weiss 4PG-N1 THERMOMETER Thermometer, 9"Scale, 3-1/2" Stem, Variable Angle Thd - Weiss 9VU35-240 Thermometer, 9"Scale, 3-1/2" Stem, Variable Angle Thd - Weiss 9VU35-240 BUTTERFLY VALVES: N/A 200# Butterfly Valve, SP-67 DI Lug Style - Milwaukee ML233E (Up to 12") 200# Butterfly Valve, SP-67 DI Lug Style - Milwaukee ML323E (14" And Larger) SWING CHECK VALVES: 125# Check Valve, Horizontal Swing Y-Pattern SP-80 Brnz Swt - Milwaukee 1509 125# Check Valve, Horizontal Swing Bolted Bonnet SP-71 CI Flg - Milwaukee F2974M N-S WAFER CHECK: 250# Ring Check Valve, Inline Lift Spring Actuated Brnz Swt - Milwaukee 1548B 125# Check Valve, Wafer Style Spring Actuated SP-125 CI Flg - Milwaukee 1400 CIRCUIT BAL VALVE: 300# Circuit Balancing Valve, Y-Pattern Brnz Thd - TA Hydronics 787 125# Circuit Balancing Valve, Y- Pattern DI Flg - TA Hydronics 788 SPECIALTIES DIELECTRIC WATERWAYS Dielectric Nipple, Brnz (LF) Thd x Thd - Victaulic 647-TT N/A PRESSURE RELIEF Pressure Relief Valve, CS Thd - Kunkle 910 Pressure Relief Valve, CS Thd - Kunkle 910 BRANCH TAKEOFF Thread-O-Let, 3000# FS Blk, T-Drill Type 2 Branchlet, Std Wt A106B SMLS FLANGES 150# Swt Companion Flange, Cast Bronze B16.24 150# WN Flange, A105 Std Wt B16.5 GASKETS Gasket, 1/8" Non-Asbestos Ring, B16.21 Gasket, 1/8" Non-Asbestos Ring, B16.21 BOLT TYPE Bolts, A307 Grade B Plated Bolts, A307 Grade B Plated VALVES NOTES: Refrigerant Liquid, Refrigerant Suction, Refrigerant Vent ITEMS 6" And Smaller PIPE MATERIALS Pipe, Copper Type ACR B280 JOINT TYPE Brz - AWS A5.8, BAg-1 or BAg-2 Silver Solder VALVES GLOBE VALVE:500# Globe Valve, Packless Brass Swt - Henry Type 626 ANGLE VALVE:500# Angle Valve, Packless Brass Swt - Henry Type 647 HAND EXPANSION VALVE: 500# Hand Expansion Valve, Packless Brass Swt - Henry Type 629 CHARGING / PURGING: 500# Globe Valve, Packless Brass Swt - Henry Type 623 GLOBE: 450# Globe Valve, Brnz Swt - Henry Type 203 FITTING MATERIAL Wrot Copper B16.22 (Long Radius) FLANGES 150# Swt Companion Flange, Cast Bronze B16.24 GASKETS Gasket, 1/8" Non-Asbestos Ring, B16.21 BOLT TYPE Bolts, A307 Grade B Plated CHECK : 500# Check Valve, Straight Through Brass Swt - Henry 120 SPECIALTIES SOLENOID VALVES Sporlan E3 or E5 Series FILTER / DRYER: R-22, LIQUID LINE Sporlan Catch-All CW-Series STRAINER, Y-PATTERN Sporlan Type 6000 PRESSURE GAUGE N/A MOISTURE-INDICATING SIGHT GLASS Sporlan "See All" SA Series 7. INSULATION FOR PLENUMS SHALL BE THE SAME AS ABOVE FOR DUCTS, DEPENDING ON SERVICE. REFER TO OUTSIDE AIR, SUPPLY, RETURN, OR EXHAUST SERVICE. 8. PROVIDE ALL SERVICE JACKET FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM JACKET FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR-RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS AND PLENUMS. 10. RETURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONDITIONED SPACE ARE CONSIDERED CONDITIONED SPACE. 4. MINIMUM R-VALUE FOR OUTSIDE AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.1.2. R-18 MEETS THIS EXTERIOR WALL REQUIREMENT FOR CLIMATE ZONES 4 AND 5. KING COUNTY IS ZONE 4C. USE R-21 FOR ZONE 6: FERRY, OKANOGAN, PEND OREILLE, AND STEVENS COUNTIES. 5. INSULATION NOT REQUIRED FOR DUCTWORK WITHIN EQUIPMENT. 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED RETURN ARE CONSIDERED UNCONDITIONED SPACE; HOWEVER, WHERE DESIGN TEMPERATURE DIFFERENCE BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. COMPLIANT WITH 2018 WA STATE ENERGY CODE, COMMERCIAL PROVISIONS (WSEC) AND 2018 SEATTLE COMMERCIAL ENERGY CODE (SCEC) NOTES: 1. OUTSIDE AIR DUCTS SERVING INDIVIDUAL SUPPLY AIR UNITS WITH LESS THAN 2,800 CFM TOTAL SUPPLY ONLY NEED R-7 INSULATION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOLATED FROM CONDITIONED SPACE WITH R-11 INSULATION. 3. INSULATE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION DAMPER. OUTSIDE THE BUILDING ALL R-8 FIBERGLASS EXHAUST AIR UPSTREAM OF DAMPER ALL NONE NA DOWNSTREAM OF DAMPER [3] ALL R-18 [4] FIBERGLASS DOWNSTREAM OF DAMPER, UNCONDITIONED SPACE ALL R-6 FIBERGLASS DOWNSTREAM OF DAMPER, CONDITIONED SPACE ALL R-8 FIBERGLASS SUPPLY AIR [5,6,9]UNCONDITIONED SPACE ALL R-6 FIBERGLASS OUTSIDE THE BUILDING ALL R-8 FIBERGLASS CONDITIONED SPACE <55 OR >105 R-3.3 FIBERGLASS CONDITIONED SPACE 55-105 NONE NA RETURN AIR [5,6]UNCONDITIONED SPACE ALL R-6 [6] FIBERGLASS CONDITIONED SPACE NA NONE [10] NA Duct Insulation Schedule DUCT TYPE [7,8] LOCATION TEMP RANGE (DEGREES F) INSULATION R-VALUE INSULATION TYPEREQUIREMENT OUTSIDE AIR [1,2,9]UPSTREAM OF DAMPER [3] ALL R-18 [4] FIBERGLASS B. PROVIDE THERMAL SHIELD INSERTS FOR ELASTOMERIC INSULATION OR USE WOOD DOWEL INSERTS WHERE REQUIRED PER MANUFACTURER'S INSTRUCTIONS. FOR SMALL PIPING (<=1-1/4") WITH ELASTOMERIC INSULATION, INSERTS AND DOWELS MAY NOT BE REQUIRED, BUT DO NOT CRUSH INSULATION OR COMPROMISE THE VAPOR BARRIER. 1. MINIMUM THICKNESS OF 1/2" IS REQUIRED BY TABLE C403.2.9 OF THE ENERGY CODE FOR THIS PIPE SIZE. 1" THICK INSULATION IS ALSO ACCEPTABLE AT NO ADDED COST IF PREFERRED BY SUBCONTRACTOR. 2. INSULATE COIL CONDENSATE PIPING WHERE LOCATED IN CONDITIONED SPACE OR ABOVE CEILING OF CONDITIONED SPACE. 3. IT IS ACCEPTABLE FOR HANGER TO PENETRATE VAPOR BARRIER AT TOP OF PIPE FOR COLD WATER AND STORM DRAIN SYSTEMS. HEATING WATER [1]HEATING WATER - LOW TEMP 105-140 0.21 - 0.28 100 FIBERGLASS NO C 1" 1" 1-1/2" 1-1/2" 1-1/2" HEATING WATER - HIGH TEMP 141-200 0.25 - 0.29 125 FIBERGLASS NO C 1-1/2" 1-1/2" 2" 2" 2" CHILLED WATER [1]CHILLED WATER 40-60 0.21 - 0.27 75 FIBERGLASS YES D 1/2" [3] 1/2" [3] 1" 1" 1" - WHERE ADDITIONAL PHYSICAL PROTECTION IS REQUIRED, PROVIDE PVC COVER IN LIEU OF UV-RESISTANT PAINT. BASIS OF DESIGN: AIREX MANUFACTURING, INC., MODEL E-FLEX GUARD OR AS APPROVED. - INSULATE AND HEAT TRACE ALL GREASE WASTE PIPING. POSITION HEAT TRACE EITHER ABOVE AND BELOW, ONE AT THE BOTTOM, OR TWO AT THE BOTTOM CENTERED ON LOWER QUARTER RADIUS. - DO NOT INSULATE FUEL OIL PIPING. THERMAL HANGER SHIELD INSERT NOTES: A. PROVIDE THERMAL INSERTS FOR ALL CHILLED WATER PIPING. MECHANICAL PIPE INSULATION SCHEDULE INSULATION SPEC PIPING SYSTEM TEMP RANGE (DEGREES F) CONDUCTIVITY MEAN RATING TEMP (DEGREES F) INSULATION TYPE VAPOR PIPE PIPE SIZE BTU*IN/ (HR*FT^ 2*F) BARRIER REQUIRED? INSERT NOTE <1" 1" TO <1 1/2" 1 1/2" TO <4" 4" TO <8" 8" & OVER REFRIGERATION [4]REFRIGERATION SUCTION <40 0.20 - 0.26 75 ELASTOMERIC YES H 1/2" [3] 1" 1" 1" 1-1/2" CONDENSATE DRAIN [2]COIL CONDENSATE DRAIN ALL 0.20 - 0.26 75 ELASTOMERIC YES H 1/2" [1] 1/2" [1] 1" 1" 1" COMPLIANT WITH 2018 WA STATE ENERGY CODE COMMERCIAL PROVISIONS (WSEC), 2018 UNIFORM PLUMBING CODE WITH WA STATE AMENDMENTS, AND 2018 SEATTLE COMMERCIAL ENERGY CODE (SCEC). NOTES: 4. VERIFY REQUIREMENTS FOR REFRIGERANT SUCTION LINES FOR EACH APPLICATION OTHER GENERAL RULES: - INSULATE ALL DIRECT BURIED PIPE UNLESS FLUID TEMPERATURE IS 60 F OR BELOW. (WSEC 2012) - FIELD APPLIED JACKETS: - PROVIDE PVC JACKETS IN MECHANICAL ROOMS FROM FLOOR TO 8 FEET ABOVE FLOOR. - PROVIDE WEATHERPROOF ALUMINUM JACKETS FOR OUTDOOR INSTALLATIONS. - PROVIDE STAINLESS STEEL JACKETS FOR EXPOSED PIPING IN FOOD PREPARATION AREAS. - FOR ELASTOMERIC PIPING OUTDOORS: - PROVIDE UV PROTECTION. PAINT INSULATION WITH 2 COATS OF "WB ARMAFLEX FINISH." NOTES: 1 - Copper - Use "Branch Takeoff" in lieu of fitting if branch piping is 1 sizes less than main or more. Example; Use 1-1/2" T-Drill in lieu of 2"x1-1/2" Tee. 2 - Carbon Steel - Use "Branch Takeoff" in lieu of fitting if branch piping is 2 sizes less than main or more. Example; Use 2-1/2" shaped nipple (saddle) in lieu of 4"x2-1/2" Tee. 3 - Contractor discretion to use other joint types for means and methods in small amount, for a complete system Chilled Water Supply and Return, Heating Water Supply and Return ITEMS 2" And Smaller 2-1/2" Through 30" PIPE MATERIALS Pipe, Copper Type L B88 Pipe, Sch 40 Blk A53B ERW (Up to 10"), Pipe, Std Wt Blk A53B ERW (12" And Larger) JOINT TYPE Press Grv VICTAULIC COUPLING N/A QuickVic Rigid Coupling - Victaulic Style 107H/107N (Up to 12") GLOBE VALVES: 125# Globe Valve, Screw-In Bonnet Integral Seat SP-80 Brnz Press - Milwaukee 502 P2 125# Globe Valve, Bolted Bonnet SP-85 CI Flg - Milwaukee F2981M BUTTERFLY VALVES: N/A 300# Butterfly Valve, DI Grv - Victaulic Vic-300 Master Seal [761] (Up to 12") 300# Butterfly Valve, DI Grv - Victaulic Vic-300 Master Seal [W761] (14" to 24") BOLT TYPE Bolts, A307 Grade B Plated Bolts, A307 Grade B Plated VALVES BALL VALVES: 150# Ball Valve, Two-Piece Full Port SP-110 Brass Press - Milwaukee BA-480B N/A GATE VALVES: N/A 250# Gate Valve, Bolted Bonnet OS&Y Solid Wedge SP-70 CI Grv - Victaulic Series 371 125# Strainer, Y-Pattern CI Flg - Mueller 758 (20" And Larger) PRESSURE GAUGE 0-100# Pressure Gauge, Aluminum Case, Brnz Thd - Weiss 4PG-N1 Pressure Gauge, Aluminum Case, Brnz Thd - Weiss 4PG-N1 THERMOMETER Thermometer, 9"Scale, 3-1/2" Stem, Variable Angle Thd - Weiss 9VU35-240 Thermometer, 9"Scale, 3-1/2" Stem, Variable Angle Thd - Weiss 9VU35-240 AGS Rigid Coupling - Victaulic Style W07 (14" And Larger) FITTING MATERIAL Wrot Copper B16.22 DI A-536, Grade 65-45-12 BRANCH TAKEOFF Type 2 Branchlet, Std Wt A106B SMLS FLANGES 150# Press Companion Flange, Cast Bronze B16.24 150# Grv Flange Adapter, DI A-536 - Anvil 788 (Up to 12") (BW Flg Alternate) 150# WN Flange, A105 Std Wt B16.5 (14" And Larger) GASKETS Gasket, 1/8" Non-Asbestos Ring, B16.21 Gasket, 1/8" Non-Asbestos Ring, B16.21 SWING CHECK VALVES: 200# Check Valve, Horizontal Swing Y-Pattern SP-80 Brnz Press - Milwaukee 509Y P2 300# Check Valve, Horizontal Swing DI Grv - Victaulic 779 N-S WAFER CHECK: 250# Ring Check Valve, Inline Lift Spring Actuated Brnz Press - Milwaukee 548T P2 300# Check Valve, Horizontal Swing DI Grv - Victaulic 716 CIRCUIT BAL VALVE: 300# Circuit Balancing Valve, Y-Pattern Brnz Thd - TA Hydronics 787 300# Circuit Balancing Valve, Y- Pattern DI Grv - TA Hydronics 789 SPECIALTIES DIELECTRIC WATERWAYS Dielectric Nipple, Brnz (LF) Grv x Thd - Victaulic 647-GT N/A PRESSURE RELIEF Pressure Relief Valve, CS Thd - Kunkle 910 Pressure Relief Valve, CS Thd - Kunkle 910 STRAINER, Y-PATTERN 125# Strainer, Y-Pattern Brnz Thd - Mueller 351M 300# Strainer, Y-Pattern DI Grv - Victaulic 732 (Up to 12") 300# Strainer, Y-Pattern DI Grv - Victaulic W732 (14" to 18") © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:04 AM3/13/2023 9:14:04 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M104 MATERIAL MATRICES 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE 50% DD 02/27/2023 33 4 4 5 5 6 6 A A B B C C D D E E F F MD112 FT-1-546 FT-1-548 FT-1-566 FT-1-584 FT-1-522 FT-1-530 FT-1-528FT-1-534 FT-1-536 FT-1-542 FT-1-540 FT-1-408 FCU-2016 FT-1-404 FT-1-400 FT-1-538 FT-1-318 FT-1-316 FT-1-532 FT-1-526 FT-1-316 FT-1-308 FT-1-524 FT-1-304 FT-1-520 EXISTING DUCTWORK TO REMAIN REMOVE EXISTING FCU AND DUCTWORK AND SAVE FOR RELOCATION. REFER TO NEW WORK PLAN. DEMO UNIT WITH DUCTWORK. TURN UNIT OVER TO BUILIDNG OWNER. CAP AT DEMISING WALL. DEMO UNIT WITH DUCTWORK. TURN UNIT OVER TO BUILDING OWENER. CAP AT DEMISING WALL. FT-1-508 SERVING EXISTING ATTRIUM IS IN CONFLICT WITH NEW WALL. SHOULD SOFFIT BE BUILT AROUND? CONSIDER DEMO AND REPLACE WITH NEW © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:08 AM3/13/2023 9:14:08 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MD111 LEVEL 1 - MECHANICAL SOUTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL SOUTH PLAN - DEMO 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR SHEET NOTES 1. REMOVE ALL GRD IN AREA OF WORK 2. CAP DUCT OPENINGS AND SEAL. 3. CLEAN ALL INTERIOR SURFACES AFTER REMOVING. 4. NOTIFY GENERAL CONTRACTOR IF ANY DUCT OR EQUIPMENT DAMAGE DISCOVERED DURING DEMOLITION WORK. 5. RELOCATED EXISTING THERMOSTATS SERVING NIC AREAS AND LOCATED IN THE AREAS OF WORK. WORK TO BE COORDINATED WITH BUILDING ENGINEER. 6. ALL WALL PATCHING SHALL BE DONE BY GENERAL CONTRACTOR. 7. COORDINATE WITH BUILDING OWNER IF ALL UNUSED TERMINALS AND GRILLES TO BE SAVED AND SALVAGED OR BE DISPOSED 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 MD111 MD113 FT-1-703 FT-1-704 FT-1-100 FT-1-102 FT-1-104 FT-1-106 FT-1-510 FT-1-512 FT-1-516 FT-1-568 FT-1-560 FT-1-562 FT-1-558 FT-1-508FT-1-506 FT-1-552 FT-1-554 FT-1-500 FT-1-412 FT-1-701 FT-1-702 FT-1-504 VERIFY IN FIELD IF ANY PIPING, DUCTS OR EQUIPMENT HAVE TO BE RELOCATED TO ALLOW NEW DUCT INSTALLATION FT-1-548 EXISTING FT1-701 CONFLICTS WITH NEW WALL. SHOULD UNIT BE MOVED OR WALL WILL BE BUILT AROUND? CONSIDER DEMO AND REPLACE WITH NEW © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:12 AM3/13/2023 9:14:12 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MD112 LEVEL 1 - MECHANICAL NORTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL NORTH PLAN - DEMO 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 50% DD 02/27/2023 SHEET NOTES 1. REMOVE ALL GRD IN AREA OF WORK 2. CAP DUCT OPENINGS AND SEAL. 3. CLEAN ALL INTERIOR SURFACES AFTER REMOVING. 4. NOTIFY GENERAL CONTRACTOR IF ANY DUCT OR EQUIPMENT DAMAGE DISCOVERED DURING DEMOLITION WORK. 5. RELOCATED EXISTING THERMOSTATS SERVING NIC AREAS AND LOCATED IN THE AREAS OF WORK. 6. ALL WALL PATCHING SHALL BE DONE BY GENERAL CONTRACTOR. 7. COORDINATE WITH BUILDING OWNER IF ALL UNUSED TERMINALS AND GRILLES TO BE SAVED AND SALVAGED OR BE DISPOSED 8. REMOVE ALL THERMOSTATS IN TI SPACES AND SAVE FOR FUTURE INSTALLAITON IF APPROVED BY THE BUILDING OWNER AND CONTROL CONTRACTOR. 4 4 5 5 6 6 G G H H J J K K L L FT-1518 FT-1-580 FT-1-570 FT-1-576 3 M601 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:15 AM3/13/2023 9:14:15 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MD113 LEVEL 1 - MECHANICAL EAST PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL EAST PLAN - DEMO 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR SHEET NOTES 1. REMOVE ALL GRD IN AREA OF WORK 2. CAP DUCT OPENINGS AND SEAL. 3. CLEAN ALL INTERIOR SURFACES AFTER REMOVING. 4. NOTIFY GENERAL CONTRACTOR IF ANY DUCT OR EQUIPMENT DAMAGE DISCOVERED DURING DEMOLITION WORK. 5. RELOCATED EXISTING THERMOSTATS SERVING NIC AREAS AND LOCATED IN THE AREAS OF WORK. 6. ALL WALL PATCHING SHALL BE DONE BY GENERAL CONTRACTOR. 7. COORDINATE WITH BUILDING OWNER IF ALL UNUSED TERMINALS AND GRILLES TO BE SAVED AND SALVAGED OR BE DISPOSED DRAWING NOTES: REMOVE EXISTING RETURN AIR DUCT WITH FSD. NOTIFY FIRE ALARM CONTRACTOR AND BUILDING ENGINEER PRIOR TO DEMOLITION WORK INFORM BUILDING OWNER AND FIRE ALARM ENGINEER ABOUT TIME REQUIRED TO COMPLETE NEW INSTALLATION. COORDINATE WITH BUILDING OWNER TEMPORARY DEMOLITION OF EXISTING GRILLES, DIFFUSERS AND DUCTWORK IN THE STORAGE ROOM DURING CONSTRUCTION. 1 1 VERIFY IN FIELD IF ANY PIPING, DUCTS OR EQUIPMENT HAVE TO BE RELOCATED TO ALLOW NEW DUCT INSTALLATION 2 2 2 2 33 4 4 5 5 6 6 A A B B C C D D E E F F MD122 CAP © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:19 AM3/13/2023 9:14:19 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MD121 LEVEL 2 - MECHANICAL SOUTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL SOUTH PLAN - DEMO 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR SHEET NOTES 1. REMOVE ALL GRD IN AREA OF WORK 2. CAP DUCT OPENINGS AND SEAL. 3. CLEAN ALL INTERIOR SURFACES AFTER REMOVING. 4. NOTIFY GENERAL CONTRACTOR IF ANY DUCT OR EQUIPMENT DAMAGE DISCOVERED DURING DEMOLITION WORK. 5. RELOCATED EXISTING THERMOSTATS SERVING NIC AREAS AND LOCATED IN THE AREAS OF WORK. 6. ALL WALL PATCHING SHALL BE DONE BY GENERAL CONTRACTOR. 7. COORDINATE WITH BUILDING OWNER IF ALL UNUSED TERMINALS AND GRILLES TO BE SAVED AND SALVAGED OR BE DISPOSED 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 MD121 COORDINATE WITH BUILDING OWNER WITH EXTENT OF DEMO WORK. DIFFUSERS TO BE MOVED 3' NORTH INTO NIC. CAP © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:23 AM3/13/2023 9:14:23 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MD122 LEVEL 2 - MECHANICAL NORTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL NORTH PLAN - DEMO 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 50% DD 02/27/2023 SHEET NOTES 1. REMOVE ALL GRD IN AREA OF WORK 2. CAP DUCT OPENINGS AND SEAL. 3. CLEAN ALL INTERIOR SURFACES AFTER REMOVING. 4. NOTIFY GENERAL CONTRACTOR IF ANY DUCT OR EQUIPMENT DAMAGE DISCOVERED DURING DEMOLITION WORK. 5. RELOCATED EXISTING THERMOSTATS SERVING NIC AREAS AND LOCATED IN THE AREAS OF WORK. 6. ALL WALL PATCHING SHALL BE DONE BY GENERAL CONTRACTOR. 7. COORDINATE WITH BUILDING OWNER IF ALL UNUSED TERMINALS AND GRILLES TO BE SAVED AND SALVAGED OR BE DISPOSED 33 4 4 5 5 6 6 A A B B C C D D E E F F M112 2 M601 C2 200 (3 TYP) C2 400 A2 200 VAV1-131 (2 TYP) C2 250A2 240VAV1-503 10"ø 12"ø8"ø VAV1-502 VAV1-501 (2 TYP) VAV1-141 N1 135 10"ø 14"ø 12"ø 10"ø (4 TYP) FCU1-511 FCU1-513 12"x12"SL26"x12"SL18"x12"SL (4 TYP)(2 TYP) (2 TYP) 1 M601 A1 100 A1 100 T 12"x10"SLSHOWERS 165 TOILETS 163 SAUNA/CYRO 146HEAD PERFORMANCE 139 EXAM 144 ALTITUDE / RECOVERY 140 HEAD MEDICAL 143 EQUIPMENT 159 HYDRO 145 MEDICAL TRAINING 138 MEDICAL AND PERFORMANCE 147 WEIGHT ROOM 137 BARBER 135 PLAYER LOUNGE 136 COACHES WORK 150 ? ?? ? COACH LOCKER 152 EQUIPMENT 155 RR 142 GROOMING 162 PLAYER PATIO 223 SECONDARY BOOT 148 STORAGE 160 CORRIDOR 126 SHAFT 127 WOMEN 129 DATA 130 ELEC 131 CONTROLS 125 STAIR 1 128 BOOT CLEANING 134 BOOT ENTRY 132 LOUNGE ENTRY 133 CORRIDOR 124 ? ? CORRIDOR 158 JAN 164 CORRIDOR 157 JAN. 152B JAN 110 PRINT ROOM 153 HEAD EQUIP 156 LAUNDRY 154 ALTITUDE BOH 141 G1 150 (4 TYP)10"ø 8"ø A2 120 A2 120 A2 185 G3 430 12"x8"26"x18"24"x16"SL (2 TYP)14"x12"A1 100 G1 130 12"x12" (4 TYP) A1 75 A1 100 A1 60 14"x12"6"ø 6"ø 12"x10"SL(2 TYP)26"x18"24"x16"SLA1 100 A2 180 (5 TYP) 12"x8" 12"x10" 12"x10" 12"x12" T T T T T T T TT T T T T G1 200 (3 TYP) G3 400 G1 250 10"x10" G1 180 E1 50 (2 TYP) 10"ø 10"ø 28"x16"36"x12"16"ø12"ø 12"x12"20"x12"22"x16"12"ø TERMINATE 10" DUCT WITH 1/2" MESH TERMINATE 12" DUCT WITH 1/2" MESH E1 50 PROVIDE 12"x12" OPENING IN THE PARTITIAN EF1-100 E2 (2 TYP) (2 TYP) E3 G2 300 14"ø FCU1-512 E4 300 DH1-141 18"x14"G5 800 G5 800 18"x14"E9 140 LOCATE GRILLE 6" ABOVE DECK VAV1-402 12"x10" C1 65 C1 150 A1 100 VAV1-403S 8"ø FCU1-411 B1 100 T ACCESS DOOR FOR LINT TRAP (TYP) LINT TRAP AND BOOSTER FAN DUE TO LENGTH LIMITATION. 6' VERTICAL 40' HORIZONTAL (2) ELBOWS E8 (4 TYP) BDD-1-01 C2 50 48"x38" OPENING COVER WITH 1/2" MESH (TYP BOTH SIDES) 48"x38" OPENING COVER WITH 1/2" MESH (TYP BOTH SIDES) FCU1-412 12"x10"SL(2 TYP) CC1-100 SF1-100 14"x10"10"x10" C1 8"x8" 12"x10" VAV1-451S 8"ø A1 100 E3 150 12"x12" (2 TYP) G3 400 18"x12"SL FT1-501 10"ø 8"ø FT1-451 FT1-351 FT1-45212"ø30"x14"E9 DBF1-3 DBF1-2 DBF1-1 8"ø L1-100 L1-101 L1-102 HWHU1-100 E1 50 (2 TYP) C1 (2 TYP) C1 (2 TYP) C1 E2 (2 TYP) (2 TYP) C1 E8 C1 E8 C1 E8 C1 E8 C1 E8 (2 TYP) C1 (2 TYP) E3 (2 TYP) C1 (2 TYP) C1 COVER WITH 1/2" MESH 12"x8" C2 E2 (2 TYP) (2 TYP) E3 C4 500 C4 260 EXISTING RELOCATED FCU. COORDINATE IN FIELD SIDE OF SERVICE CLEARANCE PRIOR TO RE-INSTALLATION. GC TO PROVIDE TEMPORARY COOLING. FCU-2106 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:34 AM3/13/2023 9:14:34 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M111 LEVEL 1 - MECHANICAL SOUTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL NORTH PLAN 1 NORTH DRAWING NOTES: INSTALL NEW DIFFUSER AND REMOTE REGULATOR BALANCE TO EXISITING FLOWS INSTALL ALDES CAR-II AIRFLOW REGULATING ELEMENT, PART #18112 FOR 20 CFM. TYPICAL ALL LOCKERS (TOTAL 31) INSTALL LINT TRAPS UPSTREAM OF THE DRYER EXHAUST FANS 1 1 1 1 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 50% DD 02/27/2023 2 22 3 3 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 M111 M113 8"ø 8"ø8"ø VAV1-111 (2 TYP) VAV1-123 A2 100 (2 TYP) A2 125 (2 TYP) VAV1-121 A1 75 A2 160 VAV1-122 (3 TYP) C2 200 (3 TYP) C2 230 C2 180 C2 275 C2 200 C2 175 C2 190 1 M601 A2 220 26"x18" 26"x18" 18"ø 12"ø8"ø A2 185 (4 TYP) A1 100 A1 100 (4 TYP) A2 120 8"ø 8"ø 10"ø 10"ø 8"ø (2 TYP) A2 150 8"ø (2 TYP) A1 100 A1 100 12"ø 8"ø TTT T T T T T TT T 12"x8" 12"x10" 12"x8" 12"x8" 12"x8" 24"x16"SL 22"x16"SL 22"x14"SL 12"x10"SL12"x10"SL12"x10"SLT FCU1-211 26"x12"SL ? ? ? ? ? ? ? ? ? ? ? ? ? ? CLASSROOM 103 TRAINING 104 DEFIANCE/ACADEMY WEIGHT ROOM 105 ? ? ? ? ENTRY LOBBY 101 ? ? MEN 123 WEST ELEVATOR LOBBY 123JAN 125 CORRIDOR 126 SHAFT 127 STORAGE 124 CORRIDOR 102 CORRIDOR 111 JAN 110 STAFF LOCKER 109 DEFIANCE LOCKER 106ACADEMY LOCKER 107 WOMEN LOCKER 108 ? ? G5 1200 44"x16"44"x16"16"x10" E1 50 8"ø 8"ø10"ø 28"x16"28"x14"24"x14"18"x14"(2 TYP) 8"ø 8"ø 8"ø 16"x14" VAV1-124 14"x14" VAV1-112 14"x14" E9 1200 10"ø 18"x14"FCU1-111 18"x12"SL (2 TYP) G3 400G2 200(4 TYP) A2 250 (4 TYP) 10"ø A2 140 N1 200 G1 150 14"x12" 36"x24" OPENING FT1-701 FT1-704 8"ø FT1-201 FT1-251 6"ø FT1-301 FT1-302 FT1-100 12"x10"SL (2 TYP) C2 C2 18"x8"COVER WITH 1/2" MESH (2 TYP) C1 7 M401 C1 (2 TYP) C1 (2 TYP) C1 (2 TYP) C1 (2 TYP) C1 COVER WITH 1/2" MESH 12"x8" C2 COVER WITH 1/2" MESH 12"x8" C2 16"x32" 16"x32" (2 TYP) E3 (2 TYP) C1 (2 TYP) E3 C6 700 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:44 AM3/13/2023 9:14:44 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M112 LEVEL 1 - MECHANICAL NORTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL NORTH PLAN 1 NORTH 3 3 3 3 DRAWING NOTES: GENERAL CONTRACTOR TO COORDINATE EXISTING DUCT WITH NEW WALL. FURR OUT NEW WALL AS NECESSARY. CONFIRM TSTAT LOCATION. RELOCATE IF NECESSARY. FIELD COORDINATED. INSTALL NEW DIFFUSER AND REMOTE REGULATOR BALANCE TO EXISTING FLOWS. RECONNECT LOW/LIN VOLTAGE CONTROL WIRES FROM THE EXISITING THERMOSTAT TO THE NEW FT 1 2 3 REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 4 SHEET NOTES 1. PROVIDE REMOTE DAMPER ACTUATORS AT EACH DIFFUSER ABOVE GWB CEILING 2. PROVIDE 24x24 ACCESS PANEL FOR EACH CONCEALED EQUIPMENT ABOVE GWB CEILING 3. PROVIDE ACCESS TO THE DISCONNECT SWITCHES ABOVE GWB. COORDINATE LOCATION WITH ELECTRICAL CONTRACTOR. 4 4 4 4 5 5 6 6 G G H H J J K K L L STORAGE 172 26"x26" UP 28"x32" FSD-2001 3 M601 FSD-1-102 FSD-1-101 16"x32" 16"x32" (2 TYP) © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:47 AM3/13/2023 9:14:47 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M113 LEVEL 1 - MECHANICAL EAST PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL EAST PLAN 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 33 4 4 5 5 6 6 A A B B C C D D E E F F M122 M111 LARGE CONFERENCE 205 RAVE GREEN 221 GM 217 SOCCER SVP 218 WAR ROOM 219 CONFERENCE 209 STORAGE 202 OFFICE 230 SOCCER OPS WORKSPACE 216 PATIO 224 COPY/PRINT 204 CORRIDOR 201 CAFE/BREAK 222 MDF 215 PLAYER PATIO 223 CORRIDOR 126 STAIR 1 128 BOOT ENTRY 132 LOUNGE ENTRY 133 CORRIDOR 158 JAN. 152B CONFERENCE 203 OFFICE 207 OFFICE 212 OWNER 220 CONFERENCE 213 OPEN WORK 214 WOMENS 225 PRINT ROOM 153 HEAD EQUIP 156 LAUNDRY 154 HEAD COACH 149 VIDEO 151 DATA 231 ELEC 232 CONTROLS 233 OFFICE 211 VESTIBULE 148b CONFERENCE 210 FT2-301 B3 250 B2 70 B2 70 B2 140 B2 90 FT2-507 OFFICE 2088"ø10"øA2 75 A4 400 A2 170 A3 330 6"ø FT2-504 A3 325 A3 325 A2 200 A3 325 10"ø8"ø12"ø A3 275 A3 275 A2 130 G3 250 G3 250 G3 250 16"ø G3 200 FT2-401 G3 200 G3 200 G3 200 G3 200 G3 200 12"ø OWNER 220 FCU1-200 36"x12" 22"x14" 22"x14" COVER OPENING WITH 1/2" MESH 20"x12" SL T 10"ø 10"ø FT2-602 FT2-601 24"x16" SL16"ø 12"ø 8"ø 14"øT20"x12" SL14"ø10"ø 10"ø T T FT2-501 20"x12" SL G3 250 16"ø14"øFT2-502 12"ø 10"ø 6"ø8"x8" SL8"ø FT2-503 T T C2 T 6"x6" SL 8"ø C1 C1 C1 T 16"x14" SL 20"x12" SLFT2-60314"ø24"x16" SL 20"ø 16"ø T FT2-604 G1 200 14"x12" SL G1 200 G1 200 G1 200 10"ø G1 200 14"x12" SL G1 20010"øG1 200 G1 200 14"ø 10"ø OWNER 220 OWNER 220 G1 200 14"x10" SL G1 200 G1 200 G1 200 14"ø 10"ø T T T 12"øT 8"x8" SLA2 75 A2 150 8"ø 8"øC1 C1 C1 T A2 150 A2 150 C1 T C1 C1 C1 16"ø B2 90 T FT2-302 12"x10" SL12"x10" SLB3 250 T12"ø10"ø 10"ø8"øC1 C1 C1 C1 C1 16"ø10"ø8"ø8"ø8"ø14"ø 14"ø14"ø14"øB5 500 B5 500 B5 500 12"ø A2 150 10"ø 8"x8" SL6"ø8"øFT2-505 FT2-402 10"ø 10"ø FT2-506 CAP EXISTING DUCT 48"x24" WALL OPENING WITH 1/2" MESH 66"x28" OPENING. COVER WITH 1/2" MESH PROVIDE 24"x12" OPENING IN WALL AND COVER WITH MESH (BOTH SIDES) TYP. © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:14:57 AM3/13/2023 9:14:57 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M121 LEVEL 2 - MECHANICAL SOUTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL SOUTH PLAN 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR DRAWING NOTES: PROVIDE REMOTE DAMPER ACTUATORS AT EACH DIFFUSER ABOVE GWB CEILING. PROVIDE FLEX CONNECTED AT INTAKE AND DISCHARGE FOR EACH FAN TERMINAL UNIT. PROVIDE 24"x24" ACCESS PANEL FOR EACH CONSEALED EQUIPMENT ABOVE GWB CEILING. PROVIDE ACCESS PANEL TO THE DISCONNECT SWITCHES ABOVE GWB. COORDINATE LOCATION WITH ELECTRICAL CONTRACTOR. 1 2 3 4 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 M111 OFFICE 230 ENTRY LOBBY 101 VESTIBULE 100 WEST ELEVATOR LOBBY 123JAN 125 CORRIDOR 126 STORAGE 124 CORRIDOR 102 CORRIDOR 111 MENS 226 CONFERENCE 227 OFFICE 228 CONFERENCE 229 FT2-202 A2 125 B3 260 A2 125 A2 125 A2 125 FT2-201 10"ø8"øB3 260 FT2-301 B2 90 FT2-3028"ø16"x14" SL 14"x10" SL G1 130 G1 130 G1 130 G1 130 16"ø 8"ø 10"ø 14"ø10"ø10"ø 12"øC1 C1 C1 T C1 T 8"ø16"x14" PROVIDE 24"x12" OPENING IN WALL ANG COVER WITH MESH (BOTH SIDES) TYP. © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:02 AM3/13/2023 9:15:02 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M122 LEVEL 2 - MECHANICAL NORTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL NORTH PLAN 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 50% DD 02/27/2023 DRAWING NOTES: PROVIDE REMOTE DAMPER ACTUATORS AT EACH DIFFUSER ABOVE GWB CEILING. PROVIDE FLEX CONNECTED AT INTAKE AND DISCHARGE FOR EACH FAN TERMINAL UNIT. PROVIDE 24"x24" ACCESS PANEL FOR EACH CONSEALED EQUIPMENT ABOVE GWB CEILING. PROVIDE ACCESS PANEL TO THE DISCONNECT SWITCHES ABOVE GWB. COORDINATE LOCATION WITH ELECTRICAL CONTRACTOR. 1 2 3 4 33 4 4 5 5 6 6 G G H H J J K K L L FOR CONTINUATION SEE SHEET M144 3 M601 MOD-R-01 MOD-R-02 RUN DUCTS BELOW EXISTING. BOD OF EXISTING DUCTS 42" AFF 26"x26"26"x26"26"x26" DN 4 M601 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:05 AM3/13/2023 9:15:05 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M133 PENTHOUSE - MECHANICAL EAST PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE SCALE: 1/8" = 1'-0" PENTHOUSE - MECHANICAL SECTORS PLAN - NEW - EAST 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 DOAS-R-1 FOR CONTINUATION SEE SHEET M133 5 M601 26"x26" RA 26"x26" SA 54"x12" SA MOD-R-01 MOD-R-024 M601 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:12 AM3/13/2023 9:15:12 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M142 ROOF - MECHANICAL NORTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE SCALE: 1/8" = 1'-0" ROOF - MECHANICAL PARTIAL PLAN - NORTH 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 33 4 4 5 5 6 6 A A B B C C D D E E F F MDP112 MDP121 1 M601 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:15 AM3/13/2023 9:15:15 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MDP111 LEVEL 1 - MECHANICAL PIPING SOUTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL PIPING SOUTH PLAN - DEMO 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 MDP121 MDP113 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:18 AM3/13/2023 9:15:18 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MDP112 LEVEL 1 - MECHANICAL PIPING NORTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL PIPING NORTH PLAN - DEMO 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 50% DD 02/27/2023 4 4 5 5 6 6 G G H H J J K K L L © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:21 AM3/13/2023 9:15:21 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MDP113 LEVEL 1 - MECHANICAL PIPING EAST PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL PIPING EAST PLAN - DEMO 1 NORTH REV DESCRIPTION DATE KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 33 4 4 5 5 6 6 A A B B C C D D E E F F MDP122 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:24 AM3/13/2023 9:15:24 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MDP121 LEVEL 2 - MECHANICAL PIPING SOUTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL PIPING SOUTH PLAN - DEMO 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 MDP121 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:26 AM3/13/2023 9:15:26 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MDP122 LEVEL 2 - MECHANICAL PIPING NORTH PLAN - DEMO 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL PIPING NORTH PLAN - DEMO 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 33 4 4 5 5 6 6 A A B B C C D D E E F F MP112 SHOWERS 165 TOILETS 163 SAUNA/CYRO 146HEAD PERFORMANCE 139 EXAM 144 ALTITUDE / RECOVERY 140 HEAD MEDICAL 143 EQUIPMENT 159 HYDRO 145 MEDICAL TRAINING 138 MEDICAL AND PERFORMANCE 147 WEIGHT ROOM 137 BARBER 135 PLAYER LOUNGE 136 COACHES WORK 150 COACH LOCKER 152 EQUIPMENT 155 RR 142 GROOMING 162 PLAYER PATIO 223 SECONDARY BOOT 148 STORAGE 160 CORRIDOR 126 SHAFT 127 WOMEN 129 DATA 130 ELEC 131 CONTROLS 125 STAIR 1 128 BOOT CLEANING 134 BOOT ENTRY 132 LOUNGE ENTRY 133 CORRIDOR 124 CORRIDOR 158 JAN 164 CORRIDOR 157 JAN. 152B JAN 110 PRINT ROOM 153 HEAD EQUIP 156 LAUNDRY 154 ALTITUDE BOH 141 HEAD COACH 149 VIDEO 151 TEAM LOCKER 161 VESTIBULE 148b FCU1-511 FCU1-512 VAV1-501 VAV1-502 FCU1-513 VAV1-503 FCU1-412 VAV1-451S VAV1-403S VAV1-402 FCU1-411 VAV1-141 VAV1-131 CC1-100 FT1-451 FT1-501 FT1-452 FT1-351 HWHU1-100 1 1/2" CHWS/R 3/4" CHWS/R 3/4" CHWS/R 1 1/4" CHWS/R 3/4" CHWS/R 3/4" CHWS/R 3/4" CHWS/R 3/4" CHWS/R 1" CHWS/R 2" CHWS/R 1/2" HWS/R 1/2" HWS/R 3/4" HWS/R 1/2" HWS/R 1/2" HWS/R 1/2" HWS/R 3/4" HWS/R 1/2" HWS/R 1" HWS/R 1/2" HWS/R 1/2" HWS/R 3/4" HWS/R 3/4" HWS/R 3/4" HWS/R 3/4" HWS/R3/4" HWS/R 2" HWS/R TERMINATE CONDENSATE AT SINK 3/4" CD 3/4" CD 3/4" CD 3/4" CD TERMINATE CONDENSATE AT MOP SINK 3/4" CD 3/4" CD BTU METER ONICON 10 FCU-2016 1 1/4" CHWS 3/4" CHWS/R TO OWNER PROVIDED BRAIN UNIT TERMINATE WITH ISOLATION VALVE © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:33 AM3/13/2023 9:15:33 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MP111 LEVEL 1 - MECHANICAL PIPING SOUTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL PIPING SOUTH PLAN 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 MP111 MP113 CLASSROOM 103 TRAINING 104 DEFIANCE/ACADEMY WEIGHT ROOM 105ENTRY LOBBY 101 MEN 123 WEST ELEVATOR LOBBY 123JAN 125 CORRIDOR 126 SHAFT 127 STORAGE 124 CORRIDOR 102 CORRIDOR 111 JAN 110 STAFF LOCKER 109 DEFIANCE LOCKER 106 ACADEMY LOCKER 107 WOMEN LOCKER 108 TEAM LECTURE 118 COACHES WORKSPACE 1123RD PARTY PRESS 117 STUDIO 115 INTERNAL CONTENT 119 WORK 113 WORK 114 ADMIN WORK 120 IDF 116 WORK 121 WORK 122 FCU1-211 VAV1-124 VAV1-111 VAV1-112 FCU1-111 FT1-301 FT1-251 FT1-302 FT1-201 FT1-100 FT1-704 FT1-701 VAV1-121 VAV1-122 VAV1-123 1" 1" CHWS/R 2" HWS/R 1/2" HWS/R 1/2" HWS/R 1" HWS/R 2" HWS/R 3/4" HWS/R 1/2" HWS/R 3/4" HWS/R 3/4" HWS/R 1/2" HWS/R 1/2" HWS/R 3/4" HWS/R 1" HWS/R 1/2" HWS/R 3/4" CD 3/4" CD TERMINATE CONDENSATE AT SINK BTU METER ONICON 10 EXISTING RELOCATED UNIT WITH HW BTU METER ONICON 10 3/4" CHWS/R 3/4" CHWS/R © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:40 AM3/13/2023 9:15:40 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MP112 LEVEL 1 - MECHANICAL PIPING NORTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL PIPING NORTH PLAN 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 50% DD 02/27/2023 4 4 5 5 6 6 G G H H J J K K L L STORAGE 172 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:42 AM3/13/2023 9:15:42 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MP113 LEVEL 1 - MECHANICAL PIPING EAST PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 1 - MECHANICAL PIPING EAST PLAN 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 33 4 4 5 5 6 6 A A B B C C D D E E F F MP122 LARGE CONFERENCE 205 RAVE GREEN 221 GM 217 SOCCER SVP 218 WAR ROOM 219 CONFERENCE 209 STORAGE 202 OFFICE 230 SOCCER OPS WORKSPACE 216 PATIO 224 COPY/PRINT 204 CORRIDOR 201 CAFE/BREAK 222 MDF 215 PLAYER PATIO 223 CORRIDOR 126 STAIR 1 128 BOOT ENTRY 132 LOUNGE ENTRY 133 CORRIDOR 158 JAN. 152B CONFERENCE 203 OFFICE 208 OFFICE 207 OFFICE 212 OWNER 220 CONFERENCE 213 OPEN WORK 214 WOMENS 225 PRINT ROOM 153 HEAD EQUIP 156 LAUNDRY 154 HEAD COACH 149 VIDEO 151 OPEN WORK 206 DATA 231 ELEC 232 CONTROLS 233 OFFICE 211 VESTIBULE 148b CONFERENCE 210 FT2-301 FT2-401 FT2-504 FT2-507 1" HWR1" HWS3/4" HWR3/4" HWS1" HWR1" HWS BTU METER ONICON 10 1" CHWS 1" CHWR 1/2" CD FCU1-200 BTU METER ONICON 10 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:47 AM3/13/2023 9:15:47 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MP121 LEVEL 2 - MECHANICAL PIPING SOUTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL PIPING SOUTH PLAN 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 MP121 OFFICE 230 ENTRY LOBBY 101 VESTIBULE 100 WEST ELEVATOR LOBBY 123JAN 125 CORRIDOR 126 STORAGE 124 CORRIDOR 102 CORRIDOR 111 MENS 226 OPEN WORK 206 CONFERENCE 227 OFFICE 228 CONFERENCE 229 FT2-301 FT2-201 FT2-202 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:50 AM3/13/2023 9:15:50 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MP122 LEVEL 2 - MECHANICAL PIPING NORTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" LEVEL 2 - MECHANICAL PIPING NORTH PLAN 1 KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR REV DESCRIPTION DATE 50% DD 02/27/2023 NORTH 33 4 4 5 5 6 6 G G H H J J K K L L 3 M601 CHWS/R AND HWS/R FOR CONTINUATION SEE SHEET MP142 1-1/2" HWR 1-1/2" HWS 2" CHWS 2" CHWR RUN CHILLED AND HOT WATER PIPES ABOVE EXISTING AHU 2" HWS 2" HWR 2" CHWR 2" CHWS BTU METER 4 M601 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:15:53 AM3/13/2023 9:15:53 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MP133 PENTHOUSE - MECHANICAL PIPING EAST PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE SCALE: 1/8" = 1'-0" PENTHOUSE - MECHANICAL SECTORS PLAN - NEW - PIPING - EAST 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR CONSTRUCTION NOTES 1. HOT TAP CONNECTIONS SHALL BE COORDINATED WITH BUILDING EENGINEER PRIOR TO INSTALLATION. 2. INSTALL MANUAL AIR VENTS AT EACH HIGH POINTS,.. 1 1 2 2 33 B B C C D D E E F F G G 2.5 2.5 HT-2 FOR CONTINUATION SEE SHEET MP133 2" HWS 2" HWR 2" CHWR 2" CHWS DOAS-R-1 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:00 AM3/13/2023 9:16:00 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MP142 ROOF - MECHANICAL PIPING NORTH PLAN 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE SCALE: 1/8" = 1'-0" ROOF - MECHANICAL SECTORS PLAN - NEW - PIPING - NORTH 1 NORTH KEY PLAN NORTH SECTOR SOUTH SECTOR EAST SECTOR CU-01 SEF-02 AC-01 EUH-02 SEF-01 SL-03 SL-01 SL-02 SBDD-01 SEF-03 EUH-03EUH-01 1/4" RL AND 1/2"RS TRANSFER GRILLES (TYP) 48"x24"x6" HOUSEKEEPING CONCRETE PAD TERMINATE CONDENSATE OUTSIDE BUILDING SL-02 SL-01 SL-03 CU-01 CU-01 1/4"RL 1/2"RS SEF-03 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:06 AM3/13/2023 9:16:06 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt MS111 MAINTENANCE SHED MECHANICAL PLANS & ELEVATIONS 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: 1/8" = 1'-0" MAINTENANCE SHED MECHANICAL PLAN 1 SCALE: 1/16" = 1'-0" MAINTENANCE SHED ROOF MECHANICAL PLAN 2 SCALE: 1/8" = 1'-0" MAINTENANCE SHED NORTH ELEVATION 3 SCALE: 1/8" = 1'-0" MAINTENANCE SHED WEST ELEVATION 4 REV DESCRIPTION DATE 50% DD 02/27/2023 1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR PENTHOUSE/ROOF PENTHOUSE ROOF DOAS-R-1 SA 6,000 CFM EA 6,000 CFM 26"x26"26"x26"OA EA DRYER (TYP. 3) C.O. 8" 10" 12" LINT TRAP L1-100 2,400 CFM EA SA L1-102 2,400 CFM EA SA © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:08 AM3/13/2023 9:16:08 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M301 MECHANICAL PIPING DIAGRAM 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE 50% DD 02/27/2023 SCALE: NTS 1 DOAS UNIT SUPPLY AND EXHAUST AIR RISER DIAGRAM CEILING DIFFUSER NOTE: ALL SUPPLY AIR DUCTWORK TO BE INSULATED DOWN TO AND INCLUDING DIFFUSER NECK, UNLESS OTHERWISE INDICATED. DIFFUSER NECK, SIZE AS NOTED ON SCHEDULE/PLAN. SUPPORT HANGER BAND FROM STRUCTURE CEILING, SEE ARCH PLANS0'-3"DRAWINGS CEILING- SEE ARCHITECTURAL CEILING RA GRILLE SECURE RA BOOT TO STRUCTURE WITH WIRE CONICAL TAPEXHAUST PLENUM SIZE TO MATCH CEILING GRILL NECK SIZE PROVIDE 1/2" SOUNDLINED SHEETMETAL PLENUM INDICATED IS A GENERIC SLOT DIFFUSER.DURING CD PHASE, PROJECT SPECIFIC DETAILS MAY BE REQUIRED TO MATCH ARCHITECTURAL APPLICATION CEILING, SEE ARCHITECTURAL PLANS LOW PRESSURE FLEXIBLE DUCT (MAX 7-FT LENGTH) BRANCH DUCT - REFER TO GRD SCHEDULE FOR SIZE SHEETMETAL COLLAR. COLLAR CONNECTION SIZE SAME AS FLEX DUCT FLEXIBLE DUCT CLAMP DCAULK CAULK BIRDSCREEN MOTORIZED DAMPER (SEE NOTE 1) SLEEVE 16 GA SHEETMETAL LOUVER OPENING PERIMETER WALL WALL PENETRATION, CUT & PATCH BY G.C. NOTE: 1. MOTORIZED DAMPER REQUIRED IN SOME JURISDICTIONS 2. SIZE EXH LOUVER @ 500 CFM & 50% FREE AREA EXHAUST LOUVER EXPOSED SPIRAL SUPPLY DUCTWORK. (SEE MECH PLANS FOR SIZE)HANGER ROD STRUCTURE ABOVE TURN IN SHEETMETAL COLLAR TO CREATE MOUNTING FLANGE DOUBLE DEFLECTION SUPPLY GRILLE. (SEE PLANS FOR SIZE, CFM & DIRECTION) MOUNT GRILLE TO FLANGE W/SCREWS, (SIMILAR IN COLOR AS SA GRILLE) MANUAL VOLUME DAMPER SEISMIC BRACING AS REQUIRED BY SMACNA 1" THICK DUCT BOARD TRANSFER BOOT (TYP, UNO) SOUND LINING - INSIDE CLEAR DIMENSION SAME SIZE AS GRILLE NECK - SHEET METAL BOOTS ONLY SECURE RA BOOT TO STRUCTURE WITH WIRE 1.TRANSFER DUCT INSIDE DIMENSION TO MATCH GRILLE NECK SIZE NOTES: OPEN DUCT CEILING - SEE ARCHITECTURAL DRAWINGS CEILING RA GRILLE SEE NOTE 1 SOUND LINING-INSIDE CLEAR DIMENSION SAME SIZE AS GRILLE SECURE FROM STRUCTURE WITH WIRE SOUND LINED TRANSFER DUCT CEILING (SEE ARCH PLANS) WALL CEILING (SEE ARCH PLANS) NOTES: 1. TRANSFER DUCT INSIDE DIMENSION TO MATCH GRILLE NECK SIZE CLEVIS HANGER CLEVIS HANGER HANGER ROD HEAVY DUTY CLEVIS HANGER LOCKING NUT PIPE LOCKING NUT INSULATION, WHERE SPECIFIED, SHALL BUTT AGAINST PIPE HANGERS SINGLE HORIZONTAL RUNS NO VAPOR BARRIER INSULATION HANGER ROD HEAVY DUTY CLEVIS HANGER LOCKING NUT PIPE VAPOR BARRIER INSULATION 16 GAGE ZINC COATED SHEET STEEL SADDLE AT LEAST 12" LONG LOCKING NUT SINGLE HORIZONTAL RUNS WITH VAPOR BARRIER INSULATION I-BEAM SIZED BY GC AND SIZED BY STRUCTURAL ENGINEER DOAS SPRING ISOLATION CURB BY MANUFACTURER 15"ROOFING MEMBRANE INSULATION © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:10 AM3/13/2023 9:16:10 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M401 MECHANICAL DETAILS 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: NTS 1 CEILING DIFFUSER DETAIL SCALE: NTS 2 CEILING EXHAUST GRILLE DUCTED CONNECTION SCALE: NTS 5 LINEAR SLOT DIFFUSER SCALE: NTS 4 LOUVER INSTALLATION DETAIL SCALE: NTS 3 TYPICAL SIDEWALL SUPPLY GRILLE DETAIL SCALE: NTS 6 CEILING RETURN PLENUM BOOT SCALE: NTS 7 CEILING TRANSFER GRILLE SCALE: NTS 8 PIPE SUPPORT DETAILS REV DESCRIPTION DATE SCALE: NTS 9 DOAS INSTALLATION CONNECTION DETAIL 7'-0" MAXFLEX DUCT1.MINIMUM 5'-0" SOUND LINING 3'-0" SOUND LINING FOR UNITS SERVING OPEN OFFICE, PRIVATE OFFICES, AND MOTHER'S ROOMS. 2.THE FIRST BRANCH SHOULD NOT BE LOCATED WITHIN THE LINED SECTION OF DUCTWORK. 3.BRANCH CONNECTION FROM MEDIUM PRESSURE MAIN TO BE 30-DEG BOOT TEE. 4. 5. MINIMUM OF 3'-0" STRAIGHT DUCT ON BOX INLET. MAXIMUM OF 5'-0" OF FLEXIBLE DUCT. INSULATE ALL PRIMARY SUPPLY AIR DUCTS BELOW 55 DEG. SHEET METAL DIFFUSER RUNOUT. SIZE TO MATCH DIFFUSER NECK SIZE. DETAIL NOTES: SEE NOTE 4 SLSM DISCHARGE SEE NOTE 1 VAV BOX SEE NOTE 5(TYP) PRIMARY SYSTEM SUPPLY AIR AVOID DIFFUSER TAPS AT END OF DISCHARGE PLENUM SPIN-IN OR EQUIV. FITTING WITH VOLUME DAMPER (TYP) LOW PRESSURE FLEX DUCT TO MATCH DIFFUSER NECK SIZE SEE SA DIFFUSER CONNECTION DETAIL (TYP) AIRFLOW DIRECTION SEE NOTE 3SEE NOTE 2 APPLY TO CONCSEALED INSTALLATION ONLY 1.DDC CONTROLS BY CONTROLS CONTRACTOR. 2.PROVIDE SERVICE CLEARANCE FOR TERMINAL UNIT CONTROLS AND COIL PIPING ACCESS. 3.COORDINATE LOCATION OF TERMINAL UNITS WITH CEILING GRID AND OTHER TRADES. LOCATE TERMINAL UNIT CONTROLS OVER REMOVABLE CEILING TILE. 4.DETAIL APPLIES TO ALL TERMINAL UNITS UNLESS NOTED OTHERWISE DETAIL NOTES: SERVICE ACCESS AREA - MAINTAIN MINIMUM CLEARANCE ACCESS PER NEC AND MANUFACTURERS RECOMMENDATIONS TERMINAL UNIT INLET CONNECTION SIZE SAME AS INLET COLLAR SIZE. SEE SCHEDULE FOR INLET SIZE SUPPLY DUCT TO BE ONE DUCT SIZE LARGER THAN TU INLET SIZE CONTROL PANEL TERMINAL UNIT HEATING COIL 15-DEG TRANSITION MINIMUM (3) DUCT DIAMETERS OR 3'-0" TERMINAL UNIT OUTLET CONNECTION SIZE SAME AS OUTLET COLLAR DISCHARGE AIR DUCT. SEE PLANS FOR SIZE. MAINTAIN (3) DUCT DIAMETERS OR 36" BETWEEN TRANSITION AND FIRST VOLUME DAMPER MINIMUM (4) DUCT DIAMETERS OR 5'-0" FLEX CONNECTOR 36" MINIMUM SECONDARY CONDENSATE DRAIN, PROVIDE EZ- TRAP DRAIN PAN OVERFLOW KIT PROVIDE SECONDARY DRAIN PAN UNDER FCU'S WHERE COOLING IS INSTALLED. (REFER TO EQUIPMENT SCHEDULE) COOLING COIL; SEE DETAIL 6 FOR COIL CONNECTION PRIMARY CONDENSATE DRAIN PROVIDE MINIMUM 5-FT OF 1" SOUND LINER ON DISCHARGE DUCT FLEX CONNECTION (TYPICAL) STRUCTURE ABOVE THREADED ROD (TYP) FILTER RACK RETURN DUCT WITH 1" INTERNAL LINER; DUCT ID TO MATCH FAN COIL RETURN AIR CONNECTION SIZE 1/2" HANGER ROD RETURN AIR OPENING VENTILATION CONNECTION REQUIRED IN IDF ROOM 3 M403 HEATING COIL (REFER TO EQUIPMENT SCHEDULE); SEE DETAIL 5 FOR COIL CONNECTION SPRING ISOLATOR (TYP) NOTE: VALVE (TYP) (SEE NOTE 2) STRAINER (SEE NOTE 4) HOSE-END DRAIN VALVE NC VALVE; SEE NOTE 5 BELOW CIRCUIT BALANCING VALVE UNION (TYP) CONTROL VALVE (SEE NOTE 3) PRESSURE TEMPERATURE PORT (TYP) MANUAL AIR VENT FLEX FTG. 12" MIN (TYP) HOT WATER HEATING COIL 5.- COPPER PIPE SYSTEMS (2"DIAMETER AND LESS) : INSTALL PERMANENT BYPASS VALVE / TEE AT COIL CONNECTIONS. - CARBON STEEL PIPE SYSTEMS (2 1/2" DIAMETER AND GREATER) :BUILD JUMPER SPOOLS IN LIEU OF PERMANENT AS SHOWN, REMOVE JUMPER SPOOLS AFTER TESTING AND FLUSHING, MAKE FINAL COIL CONNECTIONS AND SERVICE TEST JOINTS DOWNSTREAM OF BYPASS JUMPER LOOPS. 4. PROVIDE STRAINER ON COIL PIPING WHERE CONTROL VALVE IS 1" OR SMALLER 3. CONTROL VALVE PROVIDED & WIRED BY CONTROL CONTRACTOR, INSTALLED BY MECHANICAL CONTRACTOR 2. 2" & SMALLER - BALL VALVE 2 1/2" & LARGER - BUTTERFLY VALVE 1. PROVIDE MANUAL AIR VENTS ON ALL HIGH POINTS OF PIPING. PITCH LINES UP IN DIRECTION OF FLOWHWRHWSJEJE 6. LOCATE UNION TO ALLOW COIL REMOVAL WITHOUT DEASSEMBLING THE PIPING 7. MAINTAIN MINIMUM 5 STRAIT DIA UPSTREAM OF CONTROLS VALVE NOTES: BALL VALVE (<2"∅) BUTTERFLY VALVE (2"∅& ABOVE) CIRCUIT SETTER MANUAL AIR VENT w/ SHUT OFF VALVE AT HIGH POINT FLEX FTG. 12" MIN UNION (2 TYP. SEE NOTE 1.) NC; SEE NOTE 5 BELOW FLEX FTG. 12" MIN PRESSURE TEMPERATURE PORT (TYP) CONTROL VALVE (SEE NOTE 2.) BALL VALVE (<2"∅) BUTTERFLY VALVE (2"∅& ABOVE) SEE CONDENSATE DRAIN TRAP 1. USE DIELECTRIC UNIONS AT JUNCTION OF DISSIMILAR METALS. 2. 2-WAY CONTROL VALVE FURNISHED BY CONTROL CONTRACTOR. 3. THIS DETAIL IS TYPICAL FOR ALL FAN COIL UNITS, AIR HANDLERS AND HEAT RECOVERY COILS. 4. HEAT RECOVERY COILS TO BE PROVIDED W/O DRAIN PAN. DUCT TO SLOPE TO EXTERIOR LOUVER. 5.- COPPER PIPE SYSTEMS (2"DIAMETER AND LESS) : INSTALL PERMANENT BYPASS VALVE / TEE AT COIL COIL CONNECTIONS. - CARBON STEEL PIPE SYSTEMS (2 1/2" DIAMETER AND GREATER) : BUILD JUMPER SPOOLS IN LIEUOF PERMANENT BYPASS AS SHOWN, REMOVE JUMPER SPOOLS AFTER TESTING AND FLUSHING,MAKE FINAL COIL CONNECTIONS AND SERVICE TEST JOINTS DOWNSTREAM OF BYPASS JUMPER LOOPS X MX.0X HOSE-END DRAIN VALVE 6. LOCATE UNION TO ALLOW COIL REMOVAL WITHOUT DEASSEMBLING THE PIPING AxB X = A/4 R = A/2 AxB Y = R AxB R3 = E AxB R4 = R3+E W 15° (MAX) X = W/4, 4"(MIN) = 45° (TYP) 30° (MAX) 30° (MAX) MAIN SUPPLY DUCT TURNING VANES VD AIRFLOW TURNING VANES MANUFACTURED BY AIR DIFFUSION EQUIPMENT MANUFACTURER (NOT SHOP FABRICATED) R1 = C R2 = R1+C PROVIDE SMACNA 4-1/4" VANES OR H.E.P VANES BY AERO/DYNE WHERE LARGER VANES SHOWN VANES (2 GAGES HEAVIER THAN DUCT GAGE) 40% (MAX) OF MAIN SUPPLY DUCT CFM. SQUARE OR ROUND ELBOW AS SHOWN ON PLANS. A (MAX) = 45° DIVERGING, 60° CONVERGING (LOW VELOCITY, RETURN AIR, EXHAUST AIR ONLY) MAIN SUPPLY DUCT R2 = R1+A R1 = 3A/4 DUAL RADIUS 90° ELBOW RADIUS 90° TEE FITTING SQUARE THROAT 90° ELBOW AxBAxBFULL RADIUS 90° ELBOW AxBRR = A CxDSHORT RADIUS 90° ELBOWXYRR2R1CxDR2R1CxDR4R3ExFAxBBRANCH DUCT TAKE-OFFXANGLED OFFSETAxB AxBMITERED OFFSET AxBCONCENTRIC TRANSITION A ECCENTRIC TRANSITION SPLIT TYPE DUCT TAKE-OFF VD VD 0 0 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:12 AM3/13/2023 9:16:12 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M402 MECHANICAL DETAILS 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: NTS 1 SERIES FAN TERMINAL UNIT DETAIL SCALE: NTS 2 SINGLE DUCT TERMINAL UNIT DETAIL SCALE: NTS 3 ALTITUDE FAN COIL UNIT DETAIL SCALE: NTS 4 HOT WATER HEATING COIL DIAGRAM (2-WAY VALVE) SCALE: NTS 5 CHILLED WATER COIL PIPING DETAIL 2-WAY VALVE REV DESCRIPTION DATE 50% DD 02/27/2023 SCALE: NTS 6 TYPICAL DUCT FITTINGS PRIMARY INTAKE DUCT THREE DIAMETERS IN LENGTH MINIMUM, SEE SCHEDULE FOR SIZE. TRANSITION FLEXIBLE CONNECTION BRANCH DUCT SEE SCHEDULE FOR SIZE, PROVIDE IF LINEAL FEET FROM MAIN DUCT TO FTU'S GREATER THAN THREE PRIMARY INTAKE DUCT DIAMETERS. FLOOR OR ROOF ABOVE (4) 1/2"∅HANGER RODS NEOPRENE ISOLATOR (TYP) VAV BOX DISCHARGE PLENUM REMOVABLE BOTTOM ACCESS PANEL INSTALL VAV BOX HIGH AS POSSIBLE. DON'T LOCATE UNIT ABOVE LIGHT FIXTURE SEE ARCHITECTURAL PLANS FOR CEILING TYPE SERIES FAN POWERED (VAV) BOX SEE NOTE 1 CONTROLS ENCLOSURE 1.HEATING COIL, SEE PLANS AND SCHEDULES. CONFIRM CLEAR ACCESS REQUIREMENTS. DETAIL NOTES: FILTER INDUCED AIR OPENING PRIMARY AIR DUCT TRANSITION TO EQUIPMENT COLLAR SIZE (TYP) SEE PLAN FOR DUCT SIZE STRUCTURE ABOVE THREADED ROD (TYP)OPTIONAL SOUND LINED DISCHARGE, SEE PLANS MOTOR ON ADJUSTABLE BASEOPTIONAL SOUND LINED INTAKE, SEE PLANS SEE PLAN FOR DUCT SIZE (TYP) FLEX CONNECTION (TYP) SPRING ISOLATOR (TYP) SEE DEATILL 3 SEE ISOLATOR SCHEDULE (TYP.) MOTOR/BELT GUARD AIR FLOW AIR FLOW PRIMARY INDUCTION ELECTRICAL CONTROL ENCLOSURE HW COIL 6x6 J-BOX WITHOUT CONTROL ENCLOSURE LEFT HAND AIR FLOW INLET PLENUM WITH 1" THICK FIBERGLASS TAW FILTER AND RADIATED SOUND DAMPER HEATING WATER PIPING CONNECTIONS PRIMARY INDUCTION ELECTRICAL CONTROL ENCLOSURE HW COIL 6x6 J-BOX WITHOUT CONTROL ENCLOSURE INLET PLENUM WITH 1" THICK FIBERGLASS TAW FILTER AND RADIATED SOUND DAMPER HEATING WATER PIPING CONNECTIONS AIR FLOW AIR FLOW AIR FLOW RIGHT HAND NOTE: SIMILAR INSTALLATION FOR: TRANSFER FANS (T.F.) AND INLINE EXHAUST FANS (E.F.). MOUNTING BRACKET W/ LOCK WASHERS DOUBLE NUT SWAY BRACE EXPANSION SHIELD1/2"∅HANGER ROD REFERENCE SCHEDULE FOR VIBRRATION ISOLATOR TYPE (4 REQ'D) CEILING- SEE ARCHITECTURAL DRAWINGS CEILING RA GRILLE SOUND LINING- INSIDE CLEAR DIMENSION SAME SIZE AS GRILLE NECK - SHEET METAL BOOTS ONLY SECURE RA BOOT TO STRUCTURE WITH WIRE RETURN PLENUM WALL MOUNTED DUCT BOARD TRANSFER BOOT AND CEILING RA GRILLE TO BE LOCATED ON OPPOSITE SIDES OF THE ROOM FROM EACH OTHER PROVIDE DUCT BOARD TRANSFER BOOT ON CEILING RA GRILLES IF CEILING GRILLE IS LOCATED WITHIN 48" OF FTU INLET OR AS INDICATED ON PLANS WALL SLEEVE TO MATCH GRILLE NECK SIZE OPEN DUCT12" MINPLAN VIEW SECTION VIBRATION ISOLATOR (TYP) ATTACH SECURELY TO STRUCTURE HANGER ROD SLACK CABLES TO ANCHOR NUMBER OF PIPES VARIES ANGLE OR CHANNEL ANGLE OR CHANNEL LOCKING NUT (TYP) "U" BOLT (TYP) PIPE ACCESS SECTION DETAIL NOTES: HW VFD SPP VFD 1 2 3 4 5 6 Right View 7 8 9 49.2" 25.6"96.5" 171.3"5.9"47.2"88.6"49.2" 25.6" 33.5"41.3"10.8"19.7"12.2"14.6"14.6" 26.1"14.6" 26.1"HWVFDSPP VFD Front View 80.7"38.0"12.2"38.0"43.0"6.0"1 COMBINED FILTER2 HEAT RECOVERY3 WATER COOLING + WATER HEATING4 SUPPLY PLUG FAN5 OUTLET SECTION6 EXHAUST PLUG FAN7 PRIMARY FILTER8 ACCESS SECTION9 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:15 AM3/13/2023 9:16:15 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M403 MECHANICAL DETAILS 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER SCALE: NTS 2 SERIES FAN POWERED (VAV) BOX DETAIL SCALE: NTS 1 IN LINE CENTRIFUGAL EXHAUST FAN SCALE: NTS 4 FAN TERMINAL UNIT ARRANGEMENTS SCALE: NTS 3 ISOLATOR HANGER SCALE: NTS 5 TRANSFER BOOT DETAIL WALL INSTALLATION SCALE: NTS 7 TRAPEZE PIPE HANGER REV DESCRIPTION DATE 50% DD 02/27/2023 SCALE: NTS 6 DOAS DETAIL CT EC 1 2 3 H C TS SA TSTS HWSHWRCO2 TL PRIMARY AIR RA M 4 1 FILTER 2 SUPPLY FAN 3 HEATING COIL 4 PRIMARY AIR VALVE CT EC 1 2 TS SA CO2 TL PRIMARY AIR RA M 3 1 FILTER 2 SUPPLY FAN 3 PRIMARY AIR VALVE 1 TS SA CO2 TL PRIMARY AIR M 1 PRIMARY AIR VALVE 2 VAV TERMINAL 3 HOT WATER COIL H CHWR HWR3 TSTS 2 CT EC 1 2 3 C C TS SA TSTS CHWSCHWRTL RA 1 FILTER 2 SUPPLY FAN 3 COOLING COIL 13 CO2 CARBON DIOXIDE ALARM X X X 60 X AUTO CO2 LEVEL OUT OF RANGE X X 1 Equip FPVAVX-XXX FPVAVX-XXX FAN POWERED VAV START/STOP X X X X 2 FPVAVX-XXX FAN POWERED VAV STATUS X X X X 3 FPVAVX-XXX FAN POWERED VAV SPACE TEMPERATURE SET POINTS X X X 4 FPVAVX-XXX FAN POWERED VAV PRIMARY AIR POSITION X X X 60 5 FPVAVX-XXX FAN POWERED VAV HOT WATER CONTROL VALVE POSITION X X X 60 6 FPVAVX-XXX HOT WATER CONTROL VALVE X X X X X CONTROL VALVE FAILURE X X 7 8 Sensors TS SPACE TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X X 9 TL SPACE TEMPERATURE OVERRIDE X X X X 10 TS SUPPLY HOT WATER TEMPERATURE X X X 60 AUTO 11 TS RETURN WATER TEMPERATURE X X X 60 AUTO 12 CT CURRENT TRANSMITTER X X X X X MOTOR FAILURE X X ANALOG DIGITAL INPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE #Type System POINT NAME FAN POWERED VARIABLE AIR FLOW UNITS WITH HOT WATER REHEAT COIL POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail Operator3 FPVAVX-XXX FAN POWERED VAV SPACE TEMPERATURE SET POINTS X X X 4 FPVAVX-XXX FAN POWERED VAV PRIMARY AIR POSITION X X X 60 9 CO2 CARBON DIOXIDE CO2 X X X 60 X AUTO CO2 LEVEL OUT OF RANGE X X 5 6 Sensors TS SPACE TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X X 1 Equip FPVAVX-XXX FPVAVX-XXX FAN POWERED VAV START/STOP X X X X 2 FPVAVX-XXX FAN POWERED VAV STATUS X X X X 7 TL SPACE TEMPERATURE OVERRIDE X X X X 8 CT CURRENT TRANSMITTER X X X X X MOTOR FAILURE X XINPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE # Type System POINT NAME FAN POWERED VARIABLE AIR FLOW UNITS WITHOUT HOT WATER REHEAT COIL POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL CONTROL LOOPS - FAN POWERED VARIABLE FLOW TERMINALS SPACE TEMPERATURE AND PRIMARY AIR FLOW CONTROL - SINGLE DUCT VARIABLE AIR FLOW TERMINALS SPACE TEMPERATURECONTROL - 2-PIPE AND 4-PIPE FAN COIL UNITS SPACE TEMPERATURE AND PRIMARY AIR FLOW CONTROL - ERV/DOAS UNIT TEMPERATURE AND AIR FLOW CONTROL MORNING WARM UP AND COOL DOWN MORNING WARM UP AND COOL DOWN SHALL BE PROVIDED USING CONTROL ALGARIPHM TO MINIMIZE TIME FOR HEATING OR COOLING FROM UNOCCUPIED TEMPERATURE SET POINT TO OCCUPIED. - HEAT TRACE FOR EXPOSED TO AMBIENT PIPING - ALTITUDE ROOM TEMPERATURE AND AIR FLOW CONTROL - HYDROTHERAPY ROOM TEMPERATURE, HUMIDITY AND AIR FLOW CONTROL - SAUNA TEMPERATURE AND AIR FLOW CONTROL - CRYO TEMPEARURE AND AIR FLOW CONTROL GENERAL ALL EQUIPMENT SERVING CONDITIONED SPACES EXCEPT SPECIAL SPACES SHALL RUN ON BUILDING’S SCHEDULE – OCCUPIED/UNOCCUPIED (HOURS ARE ADJ.) WITH OVERRIDE FUNCTION. TEMPERATURE SET POINTS UNOCCUPIED COOLING - 85⁰F (ADJ.) UNOCCUPIED HEATING - IS 64⁰F (PER EXISTING BUILDING CONTROL SEQUENCE AND ADJ.). OCCUPIED COOLING - 72⁰F (ADJ.). OCCUPIED HEATING - 69⁰F (ADJ.). OUTSIDE AIR TEMPERATURE – REFERENCE TO GLOBAL BUILDING OA SENSOR FAN POWERED VARIABLE AIR VOLUME TERMINAL UNITS (FPVAV) TERMINALS WITH HOT WATER REHEAT COILS DURING UNOCCUPIED HOURS TERMINAL UNIT SHALL BE OFF. PRIMARY AIR VALVE IS CLOSED. COOLING – DURING UNOCCUPIED MODE HOT WATER CONTROL VALVE IS CLOSED, PRIMARY AIR VALVE IS CLOSED AND FAN IS OFF. WHEN ZONE TEMPERATURE RISES ABOVE SET POINT BY 2⁰F AND ZONE CALLS FOR COOLING, FPVAV SHALL START. PRIMARY AIR VALVE MODULATES TO FULLY OPEN POSITION. HOT WATER CONTROL VALVE REMAINS CLOSED. HEATING – UNIT TO REMAIN OFF, PRIMARY AIR VALVE AND HOT WATER CONTROL VALVE MODULATE TO CLOSED POSITION. WHEN ZONE TEMPERATURE DROPS BELOW TEMPERATURE SET POINT BY 2⁰F FAN STARTS AND HOT WATER CONTROL VALVE MODULATES TO FULLY OPEN POSITION. PRIMARY AIR VALVE REMAINS CLOSED. DURING OCCUPIED HOURS FPVAV UNIT SHALL RUN CONTINUOUSLY. COOLING –DURING OCCUPIED MODE HOT WATER CONTROL VALVE REMAINS CLOSED. PRIMARY AIR VALVE MODULATES BETWEEN MINIMUM AND MAXIMUM POSITION. WHEN SPACE TEMPERATURE FALLS BELOW SET POINT BY 2⁰F AND PRIMARY AIR VALVE IS AT MINIMUM POSITION HOT WATER CONTROL VALVE MODULATES TO MAINTAIN SET POINT (2% OPENS EACH 5 MINUTES). HEATING –DURING OCCUPIED MODE FAN RUNS CONTINUOUSLY, PRIMARY AIR VALVE MODULATES TO MINIMUM POSITION UNLESS CO2 SENSOR CALLS FOR INCREASE PRIMARY AIR. REFER TO DRAWINGS FOR CO2 SENSOR LOCATIONS. HOR WATER CONTROL VALVE MODULATES TO MAINTAIN TEMPERATURE SET POINT. TERMINALS WITHOUT HOT WATER REHEAT COILS DURING UNOCCUPIED HOURS TERMINAL UNIT TO SHALL BE OFF. PRIMARY AIR VALVE IS CLOSED. COOLING – DURING UNOCCUPIED MODE PRIMARY AIR VALVE IS CLOSED AND FAN IS OFF. WHEN ZONE TEMPERATURE RISES ABOVE SET POINT BY 2⁰F AND ZONE CALLS FOR COOLING, MAIN AHU ON THE ROOF SHALL START (THIS SHALL BE INTEGRATED INTO BUILDING CONTROL SYSTEM) AND FPVAV UNITS FOR THE EXTERIOR ZONES CALLING FOR COOLING SHALL START. PRIMARY AIR VALVE MODULATED TO FULLY OPEN POSITION. HEATING –UNIT TO REMAIN OFF AND PRIMARY AIR VALVE MODULATES TO CLOSED POSITION. DURING OCCUPIED HOURS FPVAV UNIT SHALL RUN CONTINUOUSLY. COOLING –DURING OCCUPIED MODE PRIMARY AIR VALVE MODULATES BETWEEN MINIMUM AND MAXIMUM POSITION. WHEN SPACE TEMPERATURE FALLS BELOW SET POINT BY 2⁰F AND PRIMARY AIR VALVE IS AT MINIMUM POSITION HOT WATER CONTROL VALVE MODULATES TO MAINTAIN SET POINT (2% OPENS EACH 5 MINUTES). HEATING – OCCUPIED HEATING TEMPERATURE SET POINT IS 69⁰F (ADJ.). DURING OCCUPIED MODE FAN RUNS CONTINUOUSLY, PRIMARY AIR VALVE MODULATES TO MINIMUM POSITION UNLESS CO2 SENSOR CALLS FOR INCREASE PRIMARY AIR. REFER TO DRAWINGS FOR CO2 SENSOR LOCATIONS. SINGLE DUCT VARIABLE AIR VOLUME TERMINAL UNITS (VAV) ALL SINGLE DUCR VAV RETMINALS SHALL BE PRESSURE INDEPENDENT UNITS AND FURNISHED WITH HOT WATER COILS NO MORNING WARM UP AND COOL DOWN FOR VAV. SINGLE DUCT VAV TERMINALS CONNECTED TO DOAS UNIT SINGLE DUCT VAV TERMINAL PRIMARY AIR VALVE SHALL BE INTERLOCKED WITH DOAS UNIT. VAV TERMINALS SERVING AREAS WITH FCU SHALL BE CONSTANT FLOW TERMINALS. ALL EXHAUST VAV TERMINALS SHALL CONTROL SPACE PRESSURE OF 0.03" WC TO 0.05" WC. VAV TERMINALS SERVING OTHER SPACES SHALL MODULATE TO MAINTAIN SPACE TEMPERATURE BETWEEN MAX AND MINIMUM FLOWS. HOT WATER CONTROL VALVES SHALL MODULATE WHEN PRIMARY AIR VALVE IS AT MINIMUM POSITION SINGLE DUCT VAV TERMINALSERVING HYDROTHERAPY SINGLE DUCT VAV TERMINAL PRIMARY AIR VALVE SHALL BE INTERLOCKED WITH DEHUMIDIFICATION UNIT AND BE A CONSTANT FLOW UNIT. SINGLE DUCT VAV TERMINALSERVING ALTITUDE SINGLE DUCT VAV TERMINAL PRIMARY AIR VALVE SHALL BE INTERLOCKED WITH HYPOXICO EQUIPMENT AND BE A CONSTANT FLOW UNIT. TERMINALS WITH HOT WATER REHEAT COILS DURING UNOCCUPIED HOURS TERMINAL UNIT SHALL BE OFF. PRIMARY AIR VALVE IS CLOSED AND HOT WATER CONTROL VALVE SHALL BE AT CLOSED POSITION. HEATING – DURING UNOCCUPIED MODE HOT WATER CONTROL VALVE SHALL BE CLOSED. MORNING WARM UP AND COOL DOWN 9 TS RETURN WATER TEMPERATURE X X X 60 AUTO 1 Equip VAVX-XXX VAVX-XXX PRIMARY AIR VALVE POSITION X X X 60 2 VAVX-XXX VAV SPACE TEMPERATURE SET POINTS X X X 7 TL SPACE TEMPERATURE OVERRIDE X X X X 8 TS SUPPLY HOT WATER TEMPERATURE X X X 60 AUTO 5 6 Sensors TS SPACE TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X X 3 VAVX-XXX VAV HOT CONTROL VALVE ALARM X X X X X CONTROL VALVE FAILURE X X 4 VAVX-XXX VAV HOT WATER CONTROL VALVE POSITION X X X 60INPUTOUTPUTINPUTOUTPUTINPUTOUTPUT HIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE # Type System POINT NAME VARIABLE AIR FLOW UNITS POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL 10 CT CURRENT TRANSMITTER X X X X X MOTOR FAILURE X X 4 FCUX-XXX FAN COIL UNIT CHILLED WATER CONTROL VALVE ALARM X X X X X CONTROL VALVE FAILURE X X 5 6 Sensors TS SPACE TEMPERATURE X X X 60 X AUTO SPACE TEMP OUT OF RANGE X X 7 TL SPACE TEMPERATURE OVERRIDE X X X X 8 TS SUPPLY WATER TEMPERATURE X X X 60 AUTO 9 TS RETURN WATER TEMPERATURE X X X 60 AUTO 1 Equip FCUX-XXX FCUX-XXX FAN COIL UNIT START/STOP X X X X 2 FCUX-XXX FAN COIL UNIT STATUS X X X X 3 FCUX-XXX FAN COIL SPACE TEMPERATURE SET POINTS X X X ANALOG DIGITAL INPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE #Type System POINT NAME 2-PIPE FAN COIL UNITS (REFER TO EQUIPMENT SCHEDULE)POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail Operator2-PIPE FCU TO SERVE IDF AND MDF ROOMS IN THE MAIN BUILDING FURNISHED WITH CHILLED WATER COIL ONLY. 2-PIPE FAN COIL UNITS (FCU) FCU SHALL RUN CONTINUOUSLY. CHILLED WATER CONTROL VALVE SHALL MODULATE TO MAINTAIN SPACE TEMPERATURE SET POINT OF 85⁰F (ADJ.). © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:20 AM3/13/2023 9:16:20 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M501 CONTROL DIAGRAM AND SEQUENCE 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE CT EC 1 2 4 H C TS SA TSTS HWSHWRTL RA 1 FILTER 2 SUPPLY FAN 3 COOLING COIL 4 HEATING COIL 3 C C TSTS HWSHWR3 6 H C TS SA TSTS FM EA 1 OUTSIDE AIR HOOD 2 ACCESS SECTION 3 FILTER 4 HEAT RECOVERY WHEEL C C CT1 VFD 7 M ES1 PS FS4 TS TS 5 DP 2ES3 M 1 M ES4 VFD CT2 CT3 DP 98 RA M ES2 PSTSFM 10 5 COOLING COIL 6 HEATING COIL 7 SUPPLY FAN 4 EXHAUST FAN 9 PRIMARY FILTER 10 ACCESS SECTION 4 FCUX-XXX FAN COIL UNIT CHILLED WATER CONTROL VALVE POSITION X X X 60 5 FCUX-XXX FAN COIL UNIT HOT WATER CONTROL VALVE POSITION X X X 60 6 FCUX-XXX FAN COIL UNIT CHILLED WATER CONTROL VALVE ALARM X X X X CONTROL VALVE FAILURE X X 1 Equip FCUX-XXX FCUX-XXX FAN COIL UNIT START/STOP X X X X 2 FCUX-XXX FAN COIL UNIT STATUS X X X X 3 FCUX-XXX FAN COIL SPACE TEMPERATURE SET POINTS X X X 10 TL SPACE TEMPERATURE OVERRIDE X X X X 11 TS HOT WATER SUPPLY TEMPERATURE X X X 60 AUTO 12 TS HOT WATER RETURN TEMPERATURE X X X 60 AUTO 7 FCUX-XXX FAN COIL UNIT HOT WATER CONTROL VALVE ALARM X X X X CONTROL VALVE FAILURE X X 8 9 Sensors TS SPACE TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X X 13 TS CHILLED WATER SUPPLY TEMPERATURE X X X 60 AUTO 14 TS CHILLED WATER RETURN TEMPERATURE X X X 60 AUTO 15 CT CURRENT TRANSMITTER X X X X X MOTOR FAILURE X X ANALOG DIGITAL INPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE # Type System POINT NAME 4-PIPE AND (REFER TO EQUIPMENT SCHEDULE)POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUA L BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail Operator4-PIPE FAN COIL UNITS (FCU) 4-PIPE FCU TO SERVE TO SERVE EXTERIOR ZONES IN THE MAIN BUILDING AS SHOWN ON THE DRAWINGS. FCU ARE FURNISHED WITH CHILLED AND HOT WATER COILS. FCU SHALL RUN ONLY WHEN ZONE THERMOSTAT CALLS FOR COOLING OR HEATING. REFER TO THE SPACE TEMPERATURE SET POINTS DESCRIBED IN GENERAL. DURING UNOCCUPIED HOURS TERMINAL UNIT SHALL BE OFF. CHILLED WATER AND HOT WATER CONTROL VALVES SHALL BE CLOSED. COOLING – WHEN ZONE TEMPERATURE RISES ABOVE SET POINT BY 2⁰F AND ZONE CALLS FOR COOLING, FCU SHALL START. CHILLED WATER VALVES MODULATES TO FULLY OPEN POSITION. HOT WATER CONTROL VALVE REMAINS CLOSED. HEATING – WHEN ZONE TEMPERATURE DROPS BELOW TEMPERATURE SET POINT BY 2⁰F FAN STARTS AND HOT WATER CONTROL VALVE MODULATES TO FULLY OPEN POSITION. CHILLED WATER CONTROL VALVE REMAINS CLOSED. DURING OCCUPIED HOURS FCU UNIT SHALL BE ENERGIZED AND RUN WHEN SPACE TEMPERATURE SET POINT IS NOT SUATISFIED FOR HALF AN HOUR (ADJ.). COOLING –DURING OCCUPIED MODE FCU SHALL BE OFF AND CHILLED AND HOT WATER CONTROL VALVES REMAIN CLOSED. WHEN SPACE TEMPERATURE RISES ABOVE SET POINT BY 2⁰F AND PRIMARY AIR VALVE OF ASSOCIATED VAV IS AT FULLY OPEN POSITION FCU STARTS. CHILLED WATER CONTROL VALVE MODULATES TO MAINTAIN TEMPERATURE SET POINT (2% OPENS EACH 5 MINUTES). HEATING –DURING OCCUPIED MODE FCU SHALL BE OFF AND CHILLED AND HOT WATER CONTROL VALVES REMAIN CLOSED. HEATING SHALL BE PROVIDED BY ASSOCIATED VAV. MORNING WARM UP AND COOL DOWN MORNING WARM UP AND COOL DOWN SHALL BE PROVIDED USING CONTROL ALGARIPHM TO MINIMIZE TIME FOR HEATING OR COOLING FROM UNOCCUPIED TEMPERATURE SET POINT TO OCCUPIED. DOAS UNIT DURING UNOCCUPIED HOURS TERMINAL UNIT SHALL BE OFF. CHILLED AND HOT WATER COIL VALVES SHALL BE CLOSED. COOLING MODE IS DESABLED. HEATING MODE IS DISABLED. DURING OCCUPIED HOURS DOAS UNIT SHALL RUN CONTINUOUSLY. SUPPLY FAN SHALL MAINTAIN MINIMUM VENTILATION AIR PER DUCT PRESSURE IN THE SUPPLY DUCT SET BY TAB SPECIALIST. MORNING WARM UP AND COOL DOWN MORNING WARM UP AND COOL DOWN SHALL BE PROVIDED USING CONTROL ALGARIPHM TO MINIMIZE TIME FOR HEATING OR COOLING FROM UNOCCUPIED TEMPERATURE SET POINT TO OCCUPIED. EXHAUST AIR FAN SHALL TRACK SUPPLY FAN. EXHAUST AIR SHALL BE EQUAL SUPPLY AIR AND MEASURED BY SUPPLY AND RETURN AIR FLOW METERS. COOLING –DURING OCCUPIED MODE HOT WATER CONTROL VALVE REMAINS CLOSED. CHILLED WATER CONTROL VALVE SHALL MODULATE TO MAINTAIN SUPPLY AIR TEMPERATURE AT 55⁰F. HEATING –DURING OCCUPIED MODE CHILLED WATER CONTROL VALVE SHALL BE CLOSED. HOT WATER VALVE SHALL MODULATE TO MAINTAIN 80⁰F SUPPLY AIR TEMPERATURE. TERMINALS WITHOUT HOT WATER REHEAT COILS DURING UNOCCUPIED HOURS TERMINAL UNIT TO SHALL BE OFF. PRIMARY AIR VALVE IS CLOSED. COOLING –DURING OCCUPIED MODE PRIMARY AIR VALVE MODULATES BETWEEN MINIMUM AND MAXIMUM POSITION. WHEN SPACE TEMPERATURE FALLS BELOW SET POINT BY 2⁰F AND PRIMARY AIR VALVE IS AT MINIMUM POSITION HOT WATER CONTROL VALVE MODULATES TO MAINTAIN SET POINT (2% OPENS EACH 5 MINUTES). HEATING – OCCUPIED HEATING TEMPERATURE SET POINT IS 69⁰F (ADJ.). DURING OCCUPIED MODE FAN RUNS CONTINUOUSLY, PRIMARY AIR VALVE MODULATES TO MINIMUM POSITION UNLESS CO2 SENSOR CALLS FOR INCREASE PRIMARY AIR. REFER TO DRAWINGS FOR CO2 SENSOR LOCATIONS. COOLING – DURING UNOCCUPIED MODE PRIMARY AIR VALVE IS CLOSED AND FAN IS OFF. WHEN ZONE TEMPERATURE RISES ABOVE SET POINT BY 2⁰F AND ZONE CALLS FOR COOLING, MAIN AHU ON THE ROOF SHALL START (THIS SHALL BE INTEGRATED INTO BUILDING CONTROL SYSTEM) AND FPVAV UNITS FOR THE EXTERIOR ZONES CALLING FOR COOLING SHALL START. PRIMARY AIR VALVE MODULATED TO FULLY OPEN POSITION. HEATING –UNIT TO REMAIN OFF AND PRIMARY AIR VALVE MODULATES TO CLOSED POSITION. DURING OCCUPIED HOURS FPVAV UNIT SHALL RUN CONTINUOUSLY. 30 ES4 DAMPER END SWITCH X X X X X EXHAUST AIR DAMPER FAILURE X X 5 DOAS1-0011-001 OUTSIDE AIR DAMPER POSITION X X X 6 DOAS1-001 SUPPLY AIR DAMPER POSITION X X X 7 DOAS1-001 RETURN AIR DAMPER POSITION X X X 8 DOAS1-001 EXHAUST AIR DAMPER POSITION X X X 9 DOAS1-001 CHILLED WATER CONTROL VALVE POSITION X X X # Type System POINT NAME 1 Equip DOAS1-1 DOAS1-001 SUPPLY FAN START/STOP X X X X 2 DOAS1-001 EXHAUST FAN START/STOP 3 DOAS1-001 SUPPLY FAN STATUS X X X X 4 DOAS1-001 EXHAUST FAN STATUS X X X X 15 DOAS1-001 BACNET NETWORK INTERFACE X X X 300 16 17 Sensor TS SUPPLY AIR TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X X 18 TS RETURN AIR TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X X 19 SD DUCT SMOKE DETECTOR X X X X X MANUAL SMOKE DETECTOR IN ALARM X X 20 FM SUPPLY AIR FLOW X X X 60 X X AUTO 21 FM RETURN AIR FLOW X X X 60 X X AUTO 22 PS SUPPLY AIR DUCT PRESSURE X X X 60 X X AUTO 23 FS FREEZESTAT X X X 60 X X AUTO TEMP OUT OF RANGE X X 24 CT1 CURRENT TRANSMITTER X X X X X SUPPLY FAN MOTOR FAILURE X X 25 CT2 CURRENT TRANSMITTER X X X X X EXHAUST FAN MOTOR FAILURE X X 26 CT3 CURRENT TRANSMITTER X X X X X HEAT RECOVERY MOTOR FAILURE X X 27 ES1 DAMPER END SWITCH X X X X X SUPPLY AIR DAMPER FAILURE X X 28 ES2 DAMPER END SWITCH X X X X X RETURN AIR DAMPER FAILURE X X 29 ES3 DAMPER END SWITCH X X X X X OUTSIDE AIR DAMPER FAILURE X X 10 DOAS1-001 CHILLED WATER CONTROL VALVE X X X X X AUTO CHILLED WATER VALVE FAILURE X X 11 DOAS1-001 HOT WATER CONTROL VALVE POSITION X X X 12 DOAS1-001 HOT WATER CONTROL VALVE X X X X X AUTO HOT WATER VALVE FAILURE X X 13 DOAS1-001 PRIMARY FILTER X X X X X X AUTO PRIMARY FILTER PRESSURE X X 14 DOAS1-001 FINAL FILTER X X X X X X AUTO FINAL FILTER PRESSURE X X DOAS UNIT POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL INPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:24 AM3/13/2023 9:16:24 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M502 CONTROL DIAGRAM AND SEQUENCE 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE 1 2 TS SA TL RA 1 INDOOR AIR HANDLER 2 OUTDOOR CONDENSING UNIT D XRL RSCT CT CT H SA TL RA TL HEAT TRACE HEAT TAPE SHALL BE SELF REGULATED AND MAINTAIN WATER TEMPERATURE IN THE CONTROLLED PIPES BETWEEN 50⁰F AND 55⁰F WHEN OUTSIDE AIR TEMPERATURE FALLS BELOW 40⁰F. 1 Equip DOASX-XXX DOASX-XXX SUPPLY FAN START/STOP X X X X DOASX-XXX EXHAUST FAN START/STOP 2 HEAT TRACE ALARM X X X X X AUTO HEAT TRACE FAILURE X X 2 DOASX-XXX SUPPLY FAN STATUS X X X X 1 HEAT TRACE HEAT TRACE STATUS X X X XINPUTOUTPUTINPUTOUTPUTINPUTOUTPUT HIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE # Type System POINT NAME HEAT TRACE POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL 3 SPLIT SYSTEM SPACE TEMPERATURE SET POINTS X X X 2 Sensors TS SPACE TEMPERATURE X X X 60 X AUTO SPACE TEMP OUT OF RANGE X X TL TEMPERATURE OVERRIDE X X X X 1 Equip SPLIT CU/AC IDF ROOM (MAINTENANCE SHED) X X X X SPLIT SYSTEM ALARM X X X X X AUTO SPLIT SYSTEM FAILURE X XINPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE #Type System POINT NAME SPLIT SYSTEM HEAT PUMP (REFERENCE ONLY, FOR FUTURE)POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANAL OG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL SPLIT SYSTEM SHALL BE ENABLE 24/7 AND CONTROLLED BY SPACE TEMPERATURE SENSOR. SPLIT SYSTEM SHALL MAINTAIN SPASE TEMPERATURE SET POINT OF 85⁰F (ADJ.) SPLIT SYSTEM (CUX-XXX/ACX-XXX) EXHAUST FAN FOR HYDROTHERAPY EXHAUST FAN SHALL RUN CONTINUOUSLY WHEN DEHUMIDIFIER IS ON. 3 4 Sensor CT HYDROTHERAPY EXHAUST FAN ALARM X X X X X AUTO EXHAUST FAN FAILURE X X 1 Equip EF1-100 HYDROTHERAPY EXHAUST FAN START/STOP X X X X 2 HYDROTHERAPY EXHAUST FAN STATUS X X X X XINPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE # Type System POINT NAME EXHAUST FANS POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL 3 DEHUMIDIFIER SPACE TEMPERATURE SET POINTS X X X 4 1 Equip DH1-001 DEHUMIDIFIER START/STOP X X X X 2 DEHUMIDIFIER FAN STATUS X X X X X 7 TL SPACE TEMPERATURE OVERRIDE X X X X 8 CT CURRENT TRANSMITTER X X X X X MOTOR FAILURE X X 5 Sensor H SPACE HUMIDITY HUMIDISTAT X X X 60 6 TS SPACE TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X XINPUTOUTPUTINPUTOUTPUTINPUTOUTPUTHIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE # Type System POINT NAME DEHUMIDIFIER POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL 3 SPACE TEMPERATURE SET POINTS X X X 4 7 CT CURRENT TRANSMITTER X X X X X MOTOR FAILURE X X 1 Equip UH-001 UNIT HEATER START/STOP X X X X 2 UNIT HEATER STATUS X X X X X 5 Sensor TS SPACE TEMPERATURE X X X 60 X X AUTO SPACE TEMP OUT OF RANGE X X 6 TL SPACE TEMPERATURE OVERRIDE X X X XINPUTOUTPUTINPUTOUTPUTINPUTOUTPUT HIGH ALARMLOW ALARMHYSTERISYSWhen ActiveWhen InactiveALARM MESSAGE # Type System POINT NAME UNIT HEATER POINT TYPE GRAPHICS TRENDS ALARM TRIGGERS ALARM ACTIONS ANALOG DIGITAL VIRTUAL BuildingSystemUnit DetailSTATE CHANGEVALUE CHANGESAMPLE RATE [SEC]ARCHIVETHRESHOLD TIME DELAYFAULT CLEAR: "AUTO", "MANUAL" OPERATOR AT BMS, "HARDWARE" LATCHAlarm LogPC Pop-upE-mail OperatorANALOG DIGITAL TOILET EXHAUST FAN IN MAITENANCE SHED EXHAUST FAN SHALL BE INTERLOCKED WITH THE LIGHT SWITCH DEHUMIDIFIER DEHUMIDIFIER SHALL BE CONTROLLED BY INTEGRAL CONTROLLER UNIT HEATER IN MAITENANCE SHED UNIT HEATER TO BE CONTROLLED BY LOCAL THERMOSTAT © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC, INC. 11611 49TH PL W, MUKILTEO, WA 98275 (206) 364-9900 MECHANICAL AND PLUMBING UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER 3/13/2023 9:16:28 AM3/13/2023 9:16:28 AM C:\Users\tdender\OneDrive - University Mechanical Contractors, Inc\Documents\21032_Sounders FC - MECH_Tigi_Dender.rvt M503 CONTROL DIAGRAM AND SEQUENCE 8833 SEATTLE SOUNDERS FC HQ & TRAINING 07.15.2022 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER REV DESCRIPTION DATE