Loading...
HomeMy WebLinkAboutD-401708350 355 360 365 370 375 380 385 390 350 355 360 365 370 375 380 385 390 CB#5 RIM: 387.76 IE: 384.15 12" (SW) IE: 384.15 12" (SE) IE: 384.15 12" (NE) CB#3 RIM: 386.95 IE: 383.34 12" (NW) IE: 383.34 12" (SE) CB#2 RIM: 386.82 IE: 383.05 8" (SW) IE: 382.72 12" (NW) IE: 382.72 12" (NE) EX. MH#1 RIM: 367.93 IE: 361.20 12" (SW) IE: 364.7 8" (NW) IE: 364.7 8" (NE) IE: 364.5 8" (SW) IE: 355.2 EX. 60" (NW) IE: 354.9 EX. 60" (SE) 190 LF 12" @ 9.41% 81 LF 12" @ 1.00% 62 LF 12" @ 1.00% 0+00367.93368.150+50368.93370.541+00373.00375.961+50379.02382.002+00384.60386.282+50386.75387.073+00387.24386.953+50387.21387.434+00387.70EX. 8" SEWER IE: 360.16 EX. GAS EX. WATER EST. LOCATION 1" WATER IE: 370.00 EX. POWER EST. LOCATION EX. COMM EST. LOCATION EX. WATER EST. LOCATION 1" WATER IE: 378.79 1" WATER IE: 382.99 EX. WATER EST. LOCATION EX. 8" SEWER IE: 377.10 1" WATER IE: 383.77 EX. WATER EST. LOCATION 1" WATER IE: 382.37 EX. WATER EST. LOCATION EX. WATER EST. LOCATION 1" WATER IE: 382.47 PROPOSED GRADE (TO MATCH EXISTING) PROPOSED GRADEEXISTING GRADE EX. WATER EST. LOCATION CO#4 RIM: 387.13 IE CONNECTION: 383.68 8" (SW) 73 LF 12" @ 5.05% CB#1 48" CATCH BASIN TYPE II RIM: 370.38 IE: 364.88 12" (SW) IE: 364.88 12" (NE)BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS STORM DRAINAGE PROFILE & DETAILS 3 NOT TO SCALE TRENCH AND BACKFILL 4 NOT TO SCALE PIPE ZONE BEDDING & COMPACTION 2 NOT TO SCALE SUBSURFACE UNDERDRAIN 1 SCALE: 1"=20'H, 1"=5'V STORM PROFILE EX. MH#1 TO CB#5 6 NOT TO SCALE UNDERDRAIN AGGREGATE A A SECTION A - A UNDERDRAIN AGGREGATE, SEE NOTE 1 SLOTTED UNDERDRAIN PIPE, SEE NOTE 2 CB#7 SEE PLAN AND PROFILE FOR MORE INFORMAITON CB#8 SEE PLAN AND PROFILE FOR MORE INFORMAITON SURFACE RESTORATION PER SHEET C300 SUBGRADE UNDERDRAIN AGGREGATE 2.5' MIN. WIDTH UNDERDRAIN AGGREGATE 2' MIN. DEPTH CENTERED ON PIPE NOTES 1.UNDERDRAIN AGGREGATE SHALL MEET STD. PLAN 262.60 2.UNDERDRAIN TO BE 8" SLOTTED PVC PER ASTM D1785 SCH 40. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS OF THE PIPE AND BE 0.04 TO 0.069 INCHES BY 1 INCH LONG AND BE SPACED 0.25 INCHES APART (SPACED LONGITUDINALLY). SLOTS SHOULD BE ARRANGED IN FOUR ROWS SPACED ON 45-DEGREE CENTERS AND COVER 12 OF THE CIRCUMFERENCE OF THE PIPE. SLOPE PIPE PER PLAN. 3.LOCATE UNDERDRAIN BELOW STRUCTURAL PAVEMENT BASE DEPTH. 6 C401 5 NOT TO SCALE RECTANGULAR SOLID METAL COVER 365.00 365.00 5.21% 9.26% 1.10% 1.10% 382.60 382.60 382.67 386.90 387.03 383.28 383.28 387.99 AS-BUILTAS-BUILT1 BS 06/28 JM D-401708