Loading...
HomeMy WebLinkAboutD-4017118645500170 8645500180 8645500190 8645500200 8645500210 8645500220 8645500230 8645500240 8645500250 8645600040 8645600030 8645500130 8645500140 8645500150 8645500160 RIGHT OF WAY (TYPICAL) L A K E YOUNG S W A Y S E LAKE Y O U N G S C T S E M MMMMMMM MMMMM-0+31 0+00 1+00 2+00 3 + 0 04+004+55STA:2+52.72, 23.40'LT STA:4+16.18, 40.86'RT (1) FIRE HYDRANT ASSEMBLY WITH 6' X 6' X 6" CONCRETE PAD STA:2+40.92, 4.68'RT (1) 45° BEND (MJ X MJ) WITH THRUST BLOCKING STA:2+92.77, 4.60'RT (1) 22.5° BEND (MJ X MJ) WITH THRUST BLOCKING (E) SANITARY SEWER PIPE (TYP.) (E) 4" STEEL WATER MAIN, TO BE ABANDONED IN PLACE (E) 4" STEEL WATER MAIN, TO BE ABANDONED IN PLACE STA:-0+12.57, 11.46'R POC (1) 12"X8" CUT-IN TEE (MJ X FL) (1) 12" GATE VALVE (MJ X MJ) (1) 8" GATE VALVE (FL X MJ) (3) 12" SPOOL (2) 12" TRANSITION COUPLING WITH THRUST BLOCKING STA:4+16.09, 9.07'RT (1) 8" X 6" TEE (MJ X FL) (1) 6" GATE VALVE (FL X MJ) WITH THRUST BLOCKING STA:1+05.79, 22.74'LT STA:1+73.61, 23.32'LT STA:2+19.15, 23.08'LT STA:2+21.84, 22.48'RT STA:3+80.11, 23.65'RT STA:4+42.01, 25.57'RT STA:4+42.97, 24.37'RT STA:3+27.19, 24.12'LT STA:4+14.31, 41.82'LT STA:4+42.36, 27.12'LT STA:0+44.38, 22.85'RT 2 STA:3+17.94, 23.29'LT 2 2 2 2 2 2 2 2 2 2 2 2 3 1 248 L F 8" DI PI P E 47 LF 8" DI P I P E120 LF8" D I P IPE (E) 2" STEEL PIPE, TO BE ABANDONED IN PLACE (E) 12" STEEL CONCRETE-LINED PIPE WATER MAIN (590 PRESSURE ZONE) (E) 12" STEEL CONCRETE-LINED PIPE WATER MAIN (590 PRESSURE ZONE) (E) SANITARY SEWER PIPE (TYP.) PROPOSED STORM DRAIN PIPE (TYP.)PROPOSED STORM DRAIN PIPE (TYP.) (E) UNDERGROUND TELECOMMUNICATIONS (E) UNDERGROUND ELECTRIC UTILITY (E) 2" BLOWOFF ASSEMBLY TO BE ABANDONED (E) 6" STEEL WATER MAIN, ABANDONED13' 12' (E) 6" STEEL WATER MAIN, ABANDONED 5.2' (E) FIRE HYDRANT ASSEMBLY 9' 14' 13' 9.5' (E) 12" STEEL WATER MAIN, ABANDONED (E) 12" STEEL WATER MAIN, ABANDONED (E) 6" STEEL WATER MAIN, ABANDONED 4 4 4 4 4 4 3' 5' (E) FENCE, PROTECT IN PLACE (E) FENCE, REMOVE AND RESTORE AS NEEDED 5 6(1) 4" PLUG (MJ) (1) 4" CAP 8 7 JOINT RESTRAINT SYSTEM BEGIN APPROX. STA 2+01.00 END APPROX. STA 3+32.00 SEE GENERAL NOTE 6BID SETLAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS 1.WATER MAIN SHALL BE CLASS 52 DUCTILE IRON PIPE WITH POLYETHYLENE ENCASEMENT. 2.WATER MAIN SHALL BE INSTALLED WITH NO LESS THAN THREE FEET (3') AND NO MORE THAN SIX FEET (6') COVER FROM FINISHED GRADE TO TOP OF PIPE. WATER MAIN SHALL BE INSTALLED NO LESS THAN SIX INCHES (6") ABOVE NEW AND EXISTING STORM DRAIN AND SANITARY SEWER PIPES, MEASURED FROM EDGE OF PIPE TO EDGE OF PIPE. 3.NEW WATER MAIN SHALL BE INSTALLED NO LESS THAN FOUR FEET (4') HORIZONTALLY FROM EXISTING (TO BE ABANDONED) WATER MAIN. 4.INSTALLATION OF CUT-IN TEE SHALL BE FACILITATED BY SHUTTING THE WATER VALVES (TO BE DONE BY CITY FORCES) AT THE FOLLOWING LOCATIONS: 4.1.APPROXIMATELY 405' NORTHWEST OF THE POINT OF CONNECTION, IN LAKE YOUNGS WAY SE, SOUTH OF THE INTERSECTION WITH SE ROYAL HILLS DRIVE. 4.2.APPROXIMATELY 245' SOUTHEAST OF THE POINT OF CONNECTION, AT THE NORTHERN CORNER OF THE INTERSECTION OF LAKE YOUNGS WAY SE AND SE 16TH STREET. 5.TRENCH REQUIREMENTS SHOWN ON DETAIL 2, SHEET C301. 6.RESTRAINT SYSTEM FOR PUSH-ON PIPES SHALL BE INSTALLED AT THE LOCATIONS INDICATED AND SHALL BE HARNESS-TYPE, MEGALUG SERIES 1700, ROMAC 600 SERIES, OR EQUAL. RESTRAINT SYSTEM SHALL BE INSTALLED A MINIMUM TWO JOINTS OR 36' FROM EACH FITTING. 7.ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE WEDGE-TYPE RESTRAINED RETAINER GLANDS EQUAL TO MEGALUG SERIES 1100 OR ROMAC ROMAGRIP. 8.INSTALL ALL CONCRETE THRUST BLOCKING PER CITY STANDARD PLANS; SEE DETAILS 1-3, SHEET C502. 9.INSTALLATION OF NEW WATER SERVICES SHALL BE PERFORMED VIA HOLE HOG METHOD BENEATH EXISTING SIDEWALK. 10.CONSTRUCTION AND TRANSFER OF DOMESTIC SERVICES SHALL BE PERFORMED SUCH THAT EACH SERVICE IS MINIMALLY DISRUPTED. 11.TRANSFER OF WATER SERVICES TO BE PERFORMED BY CONTRACTOR; METER SETTING TO BE PERFORMED BY CITY FORCES. 12.CONTRACTOR SHALL RESTORE DISTURBED AREAS TO ORIGINAL CONDITION OR BETTER. WATER UTILITY PLAN N KEY NOTES POINT OF CONNECTION TO EXISTING WATER MAIN. INSTALL 1" DOMESTIC WATER SERVICE AND METER BOX AND CONNECT TO EXISTING PRIVATE SERVICE LINE BEHIND ROW LINE. CITY FORCES TO REINSTALL EXISTING AMI METER TO NEW SETTER. REMOVE AND SALVAGE EXISTING METER BOX AND SETTER. INSTALL FIRE HYDRANT ASSEMBLY. EXISTING, ABANDONED STEEL WATER MAIN TO BE CUT AND CAPPED AS NEEDED FOR CONSTRUCTION OF NEW WATER MAIN AND STORM DRAIN IMPROVEMENTS. INSTALL WATER MAIN USING PIPELINE DEFLECTION PER MANUFACTURER GUIDELINES TO ACHIEVE DESIGN ALIGNMENT. UPON FINAL CONNECTION OF NEW WATER MAIN TO EXISTING SYSTEM AND TRANSFER OF ALL DOMESTIC SERVICES, CUT AND CAP EXISTING 4" STEEL WATER MAIN AND INSTALL 4" MJ PLUG ON EXISTING GATE VALVE. REMOVE LID AND TOP SECTION OF VALVE BOX. EXISTING SECTION OF ROADWAY TO BE REMOVED AND REPLACED. EXISTING 2" BLOW-OFF ASSEMBLY TO BE ABANDONED, LID AND TOP SECTION OF VALVE BOX TO BE REMOVED. EXISTING SECTION OF CONCRETE SIDEWALK TO BE REMOVED AND REPLACED. POLYPIG STATION. 1 2 3 4 5 6 7 8 GENERAL NOTES Feet 1" = 20' 4020010WTR - 27 - 40171 C501 5 C502 3 C501 2 C501 5 C501 4+11.6, 10.0' RT 4+13.4, 41.2' RT -0+11.7, 10.1' RTAS-BUILTAS-BUILT1 BS 06/28 JM D-401711