HomeMy WebLinkAboutD-4017120+00 STA:-0+12.57, 11.46'RT POC (1) 12"X8" CUT-IN TEE (MJ X FL) (1) 12" GATE VALVE (MJ X MJ) (1) 8" GATE VALVE (FL X MJ) (3) 12" SPOOL (2) 12" TRANSITION COUPLING WITH THRUST BLOCKING NOTE: FIELD VERIFY OD OF STEEL PIPE PRIOR TO ORDERING TRANSITION COUPLING 0+00BID SETLAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS WATER UTILITY DETAILS 10' ± FINAL CONNECTION TESTING CONNECTION (1) 8" CROSS (MJ x FL) (1) BLIND FLANGE ON TOP WITH 2" TAP & 2" PLUG (1) BLIND FLANGE ON BOTTOM WITH TEMPORARY BLOCKING (1) 8" SPOOL (1) PLUG (MJ) WITH 2" TAP & 2" TEMPORARY BLOWOFF WITH TEMPORARY BLOCKING UPON COMPLETION OF TESTING, CLEANING BY POLYPIG, AND DISINFECTION, REMOVE CROSS, TEMPORARY BLOCKING, AND TEMPORARY BLOW-OFF ASSEMBLY; CONNECT TO EXISTING WATER LINE WITH SLEEVES (MJ) AND DI SPOOLS; FINAL CONNECTION BY CITY FORCES 8" DI LENGTH AS NEEDEDWTR - 27 - 4017(E) 12" X 4" STEEL TEE (E) 12" STEEL CONCRETE-LINED WATER MAIN (E) 4" STEEL WATER MAIN, TO BE ABANDONED (E) STORM DRAIN PIPE (E) SANITARY SEWER PIPE (E) 12" STEEL CONCRETE-LINED WATER MAINLAKE YOUNGS WAY SELAKE YOUNGS WAY SE(E) 12" STEEL WATER MAIN, ABANDONED (E) 6" STEEL WATER MAIN, ABANDONED (E) 12" STEEL WATER MAIN, ABANDONED N 3' MIN. COVER (10" DIAMETER AND UNDER)4' MIN. COVER (12" DIAMETER AND OVER) TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE INSTALL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG NEW WATER MAIN POLYPIG FINISHED GRADE ELEVATION VERTICAL CROSS FOR POLYPIGGING STATION: (1) 8" X 8" VERTICAL CROSS (MJ x FL) (1) BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW-OFF ASSEMBLY (REMOVE BLOW-OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING POLYPIG) (1) BLIND FLANGE ON BOTTOM OF CROSS (1) PLUG (MJ) ON END OF CROSS WITH TEMPORARY CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN I F HG E K L B M A J J 1' 4" 2'1' 2"-4" PER MANUFACTURER'SRECOMMENDATION 1' ASPHALT CONCRETE PAD 2' DIA. X 2" THICK ROADWAY OR NEAREST CHANNELIZATION36" MIN. COVER1' MIN. MAIN D C 1' MIN. A FIRE HYDRANT SHALL BE COMPRESSION TYPE SUCH AS CLOW MEDALLION, MUELLER SUPER CENTURION 250, AND AMERICAN DARLING B-62-B WITH 6" MECHANICAL JOINT INLET WITH LUGS, 5-1/4" MAIN VALVE OPENING, TWO 2-1/2" HOSE CONNECTIONS, NATIONAL STANDARD THREADS, 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON REGIONAL FIRE AUTHORITY. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT. TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT, VALVE NUT EXTENSION AS REQUIRED. SEE DETAIL 6, SHEET C502. 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT. MEGALUG JOINT RESTRAINT OR 2-3/4" CORTEN STEEL TIE RODS FOR DISTANCES OVER ONE PIPE LENGTH. 1/2 CUBIC YARD OF 1-1/4" WASHED DRAIN ROCK 1' ABOVE BOOT FLANGE. PLACE 8 MIL POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. 16" X 8" X 4" MIN. SIZE CONCRETE BLOCK UNDER HYDRANT AND VALVE. CONCRETE BLOCKING PER DETAILS 1-3, SHEET C502.. 3' MIN. RADIUS OF LEVEL GROUND AROUND OUTSIDE OF HYDRANT. 6' X 6' X 6" THICK CONCRETE PAD AROUND HYDRANT. FINISH TO MATCH SIDEWALK. RAISED PAVEMENT MARKER TYPE 88-A STIMSONITE TWO-WAY BLUE REFLECTIVE, PER DETAIL 5, SHEET C502. 4.875" X 5" STORZ ADAPTER. B C D E F G H I J K L M AA VALVE BOX LID WITH EARS IN DIRECTION OF WATER MAIN AND CAST WITH WORD "WATER" 2-PIECE CASE IRON VALVEBOX, RICH-SEATTLE TYPE OR OLYMPIC FOUNDRY 1/8" MIN. THICKNESS 1" STEEL LENGTH AS REQUIRED 4 14" DIA. 1/8" MIN. THICKNESS WHITE POST SEE DETAIL INSTALL 8" THICK HMA COLLARFOR VALVES IN PAVED AREAS PER STD PLAN 106 OR 6" THICK, 3' X 3' CONCRETE PAD IN UNPAVED AREAS 12" MIN.18" MAX. VALVE OPERATION NUT EXTENSION NOTES: EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN 3 FEET (3') BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF 1 FOOT (1') LONG. ONLY ONE EXTENSION TO BE USED PERVALVE. ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, AND PAINTED WITH TWO COATS OF METAL PAINT. VALVE MARKER NOTES: VALVE MARKERS SHALL BE EQUAL TO CARSONITEUTILITY MARKER. VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS. SECTION A–A VALVE OPERATING NUT EXTENSION VALVE MARKER POST 2 14" INSIDE MEASUREMENT 2 14" DEPTH 2" SQUARE OPERATING NUT 12" OF WATER MAIN PLAN VIEW 3 34" 38" 24" 62" 3" MIN. WIDTH HYDRANT MARKERS TWO LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LINE) ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAIN TRAVELED STREET, THE MARKER IS TO BE INSTALLED ON THAT MAIN STREET FOUR LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) FIVE LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) RAISED PAVMENT MARKER TYPE 88-A STIMSONITE TWO-WAY BLUE REFLECTIVE MARKER MARKER MARKER MARKERMARKER 0.7" 4" 1 NOT TO SCALE CONNECTION TO WATER MAIN 2 NOT TO SCALE HYDRANT MARKER LAYOUT 4 NOT TO SCALE VALVE BOX & OPERATING NUT EXTENSION 5 NOT TO SCALE POLYPIG STATION 3 NOT TO SCALE FIRE HYDRANT ASSEMBLY UPON FINAL CONNECTION OF NEW WATER MAIN TO EXISTING SYSTEM, CUT AND CAP EXISTING 4" STEEL WATER MAIN AND INSTALL (1) 4" MJ PLUG (1) 4" CAP MICHAEL J A MES MIT CHELLPROF ESSIONAL ENG IN EE RREGISTEREDSTATE OF WASHIN G TONEXP. 11/21/2019 WATER UTILITY agafour 05/16/2019AS-BUILTAS-BUILT1 BS 06/28 JM D-401712