Loading...
HomeMy WebLinkAboutD-401713BID SETLAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS WATER UTILITY DETAILSWTR - 27 - 401790° BEND SAFE BEARING LOADS IN LB./SQ.FT. THE SAFE BEARING LOADS GIVEN IN THE FOLLOWING TABLE ARE FOR HORIZONTAL THRUSTS WHEN THE DEPTH OF COVER OVER THE PIPE EXCEEDS TWO FEET (2'). SOIL * MUCK, PEAT, ETC. SOFT CLAY SAND SAND & GRAVELSAND & GRAVEL, CEMENTED WITH CLAY HARD SHALE SAFE BEARING LOADS IN LB./SQ.FT. 0 1,000 2,000 3,000 4,000 10,000 * IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATIONS OR BY REMOVAL OF MUCK OR PEAT AND REPLACEMENT WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. NOTES: 1.SQUARE FEET OF CONCRETE THRUSTS - BLOCK AREA BASED ON SAFE BEARING LOAD OF 2,000/(3,000) POUNDS PER SQUARE FOOT. 2.AREAS MUST BE ADJUSTED FOR OTHER SIZE PIPE, PRESSURES, AND SOIL CONDITIONS. 3.CONCRETE BLOCKING SHALL BE CAST IN PLACE AND HAVE MINIMUM 1/4 SQUARE FOOT BEARING AGAINST THE FITTING. 4.BLOCK SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. 5.CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. PRESSURE PSI A B C D E X (100 PSI)PIPE SIZE 4"200300 2/(1) 3/(2) 1/(NONE) 2/(2)NONENONE NONE1/(NONE) 2/(1) 1/(NONE) 1/(1) 6"200 300 4/(3) 6/(4) 8"200 300 7/(5) 11/(8) 10"200 275 11/(8) 16/(11) 16/(11) 24/(16)12"200 250 14"200 250 16"200 225 18"200 20"200 24"200 3/(2) 4/(3) 5/(3) 8/(5) 8/(6) 11/(7) 3/(1) 3/(2) 4/(3) 6/(4) 6/(4) 9/(6) 1/(1) 2/(1) 2/(2) 3/(2) 3/(2) 5/(3) 1/(NONE) 1/(NONE) 1/(1) 2/(1) 2/(1) 3/(2) NONE 3/(2) 4/(3) 5/(4)11/(8) 17/(11) 9/(6) 13/(9) 5/(3) 7/(5) 3/(2) 4/(3) 22/(13) 33/(22)7/(6)16/(11) 23/(16) 12/(8) 18/(12) 6/(4) 9/(6) 3/(2) 5/(3) 29/(19) 32/(21)10/(7)21/(14) 23/(16) 16/(11) 17/(12) 8/(6) 9/(6) 5/(3) 5/(3) 13/(9) 16/(11) 23/(16) 5/(4) 7/(4) 9/(6) 10/(7) 13/(8) 18/(12) 20/(13) 24/(16) 35/(23) 26/(17) 32/(21) 46/(30) 36/(24) 45/(29) 64/(43) MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL, IN SQUARE FEET THRUST BLOCK - TABLE CAP 22 1/2° BEND 45° BEND TEE 11 1/4° BEND A B C B D E VERTICAL BEND CU FT 11 1/4°* A D LV BPIPESIZE * * 16 2.5'3/4"2.0' * * 33 86 3.2' 4.4' * 13 64 141 4.0' 3.5'1"5.2' * 2.3' 22 1/2° 45° 90° 11 1/4° 22 1/2° 45° 90° 11 1/4° 22 1/2° 45° 90° 11 1/4° 22 1/2° 45° 90° 4" 6" 8" 10" 12" 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 2.3' 3.5' 13 43 * * 20 111 206 4.8' 5.9' 2.7' 1 1/8"4.0' 11 1/4° 22 1/2° 45° 90° VERTICAL BLOCKING SIZE W/RESTRAINED JOINTSSOIL TYPE = COHESIVE GRANULAR [GC+SC] SAND, GRAVEL, CLAY MIXTURE NOTES: 1.NO CHANGE IN PIPE DIRECTION OR DIAMETER SHALL OCCUR WITHIN 36 FEET OF THE VERTICAL BEND. BENDS, TEES, REDUCERS, ETC., BEYOND THE 36-FOOT LIMIT SHALL BE RESTRAINED BY STANDARD CONCRETE BLOCKING PER DETAILS 2 & 3, SHEET C502. 2.CONCRETE BLOCKING SIZES BASED ON: - 36 FEET OF PIPE RESTRAINED EACH SIDE OF BEND. - THRUST BLOCK AREAS BASED ON SAFE BEARING LOAD OF 1,000 PSF. - 2,500 PSI CONCRETE. - MINIMUM 3 FEET (3') OF COVER. - PIPE THRUST BASED ON 200 PSI PRESSURE. - PIPE AND FITTINGS ENCASED IN POLYETHYLENE. - VERTICAL BLOCK SIZE BASED ON CONCRETE WEIGHT OF 150 PCF. - TRENCH CONDITIONS BASED ON TYPE 2, FLAT BOTTOM TRENCH WITH LIGHTLY CONSOLIDATED BACKFILL, PER ANSI/AWWA C150/A21.50. - FACTOR OF SAFETY = 1.5. - SOIL FRICTIONAL RESISTANCE BASED ON COHESIVE GRANULAR SOIL TYPE (GC+SC), SAND, GRAVEL, CLAY MIXTURE. 3.BLOCKING DESIGN MUST BE ADJUSTED FOR OTHER SIZE PIPE, PRESSURES, AND SOIL CONDITIONS. 4.PIPE CLAMP (HOT DIPPED GALVANIZED), RODS (STAINLESS STEEL ALL-THREAD 316SS). SEE DETAIL 4, SHEET C502. 5.LINE SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100 FEET OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM COVER OF 3 FEET (3') OVER PIPE. 6.90° VERTICAL BENDS SHALL ONLY BE INSTALLED WHERE GIVEN PRIOR APPROVAL BY THE UTILITY. 7.BACKFILL TRENCH BEYOND 90° VERTICAL BLOCK WITH CRUSHED SURFACING TOP COURSE MATERIAL COMPACTED TO 95% MAXIMUM DENSITY. CRUSHED BACKFILL SHALL EXTEND 20 FEET BEYOND BLOCK OR TO FIRM BEARING TRENCH WALL, WHICHEVER IS LESS. 8.LEAVE BLOCK OPEN OR SHEETED 24 HOURS MINIMUM. 9.MEGALUG FITTINGS. A L A D PIPE CLAMPS & RODS (SEE NOTE 4) 45° SEE NOTE 9 (TYPICAL) VERTICAL BLOCKING FOR 90° BENDS (SEE NOTE 6) L A L A COMPACTED BACKFILL (SEE NOTE 7) D PIPE CLAMPS & RODS (SEE NOTE 4) 90° L A L A UNDISTURBEDEARTHD PIPE CLAMPS & RODS (SEE NOTE 4) SEE NOTE 9 (TYPICAL) L VERTICAL BLOCKING FOR 11 1/4° & 22 1/2° BENDS D PIPE CLAMP & RODS (SEE NOTE 4) A L A UNDISTURBEDEARTHD 45° SEE NOTE 3 (TYPICAL) L VERTICAL BLOCKING FOR 45° BENDS VERTICAL BEND A L A UNDISTURBEDEARTHD L VERTICAL BLOCKING FOR 11 1/4° & 22 1/2° BENDS D PIPE CLAMP & RODS (SEE NOTE 4) NOTES: 1.CONCRETE BLOCKING BASED ON 200 PSI PRESSURE AND 2,500 PSI CONCRETE. 2.LEAVE CLOCK OPEN OR SHEETED 24 HOURS MINIMUM. 3.JOINT RESTRAINT, SEE APPROVED MATERIALS LIST. 4.PIPE CLAMP (HOT DIPPED GALVANIZED), RODS (STAINLESS STEEL ALL-THREAD 316SS), SEE DETAIL 4, SHEET C502. CU FT 11 1/4°8 A D LV BPIPE SIZE 11 17 22 1/2° 30° 11 1/4° 22 1/2° 30° 4" 6" 8" 7/8"3.0' 1 1/4"4.0' 91 225 330 6.1' 6.9' 4.5' 1 3/8"4.5' 11 1/4° 22 1/2° 30° VERTICAL BLOCKING FOR 11 1/4°, 22 1/2°, & 30° BENDS 2.0' 2.2' 2.6' 3/4" 1.5' 2.0' 11 1/4°11 25 41 22 1/2° 30° 2.2' 2.9' 3.5' 3/4"2.0' 11 1/4°16 47 70 22 1/2° 30° 2.5' 3.6' 4.1' 3/4" 2.5' 2.0' 12" 11 1/4°32 88 132 22 1/2° 30° 3.2' 4.5' 5.1' 3/4"2.0' 3.0'7/8" 16" 70 184 275 4.1' 5.7' 6.5' 7/8"3.0' 4.0'1 1/8" 1 1/4" 20" 1"3.5' 1 3/8"4.5' 128 320 480 6.8' 7.9' 5.0' 1 5/8"5.5' 11 1/4° 22 1/2° 30° 24" 4" 6" 8" 12" 16" 20" 24" 45° 3/4"2.0'68 123 232 5.0' 6.1' 4.1' 3/4"2.5' 30 3.1' 1 1/8"4.0'1 1/4" 478 560 820 8.2' 9.4' 7.8' 1 3/8"4.5' VERTICAL BLOCKING FOR 45° BENDS HOST PIPE HEAVY DUTY PIPE CLAMP (COOPER B-LINE B3132 PIPE CLAMP OR EQUAL) HOT DIPPED GALVANIZED NUT WITH FLAT WASHER, TOP AND BOTTOM (TYP.) ASTM A588, GRADE B, CORTEN ALL THREADED ROD (2) NUTS WITH FLAT WASHER (TYP.) NOTES: 1.THREADED ROD DIAMETER: - PIPE DIAMETER LESS THAN OR EQUAL TO 6": 7/8" - PIPE DIAMETER EQUAL TO 6" OR 8": 1" - PIPE DIAMETER EQUAL TO 10": 1 1/4" - PIPE DIAMETER GREATER THAN 12": 1 1/2" 2.TIGHTEN TOP NUTS TO TENSION BOLTS. 3.TIGHTEN LOWER NUTS TO COMPRESS CLAMP SNUG. C C B A E D 18" 24" MIN. 30" MAX. COVER PRIVATE PLUMBING SHALL CONNECT HERE 1" GALV. PLUG PRIVATE PROPERTY PUBLIC R.O.W. 9-12" NEW DUCTILE IRON WATER MAIN 36" MIN.COVER A EPOXY OR NYLON COATED HIGH TENSILE DI SERVICE SADDLE W/ STAINLESS STEEL STRAP AND EPOXY COATED BOSS, 1" AWWA TAPERED THREAD (CC) TAP, FORD FC101 OR EQUAL, SIZE AS REQUIRED. (FOR ASBESTOS CEMENT PIPE ONLY) 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET (1" FB1000-4-Q) OR AY MCDONALD 4701B FOR COPPER. (DIRECT TAP DUCTILE IRON OR CAST IRON PIPE) 1" TYPE K SOFT COPPER TUBING METER SETTER FOR 1" METER: FORD VBH72-15W-44-44A, MCDONALD BRASS 21-415WCQQ44, OR MUELLER 1-B-2470-2.BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT. METER SETTER SHALL BE INSTALLED CENTERED AND PARALLEL WITH METER BOX. FOR 5/8" X 3/4" METER, PROVIDE METER ADAPTERS TO FIT WITHIN 1" METER SETTER. ARMORCAST PRODUCTS CO. METER BOX NO. A6001946TX18 AND CAST IRON READ LID, 13" X 24" X 2", PART NO. A6001969RCI-H7. B C D E NOTES: 1.SERVICE LINE SHALL BE PERPENDICULAR TO THE WATER MAIN, UNLESS OTHERWISE APPROVED BY THE ENGINEER. 2.APPROVED BACKFLOW PREVENTION MUST BE INSTALLED WITH IRRIGATION SERVICE PER D.O.H. REQUIREMENTS. IRRIGATION SYSTEM SHALL NOT BE PUT INTO SERVICE UNTIL THE BACKFLOW PREVENTION DEVISE IS APPROVED BY ACITY OF RENTON WATER QUALITY TECHNICIAN. 3.AMI WATER METER WITH RADIO & BATTERY UNIT TO BE SUPPLIED BY CITY OF RENTON PUBLIC WORKS DEPARTMENT. 4.IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE, INSTALL FORD C14-33 OR 44 FIPT x COMPRESSION COUPLING. 22 1/2° 12" MIN. RADIUS 1 NOT TO SCALE VERTICAL BLOCKING WITH RESTRAINED JOINTS 2 NOT TO SCALE CONCRETE BLOCKING 3 NOT TO SCALE CONCRETE BLOCKING FOR VERTICAL FITTINGS 4 NOT TO SCALE PIPE CLAMP AND ANCHOR RODS 5 NOT TO SCALE 1-INCH WATER SERVICE MICHAEL J A MES MIT CHELLPROF ESSIONAL ENG IN EE RREGISTEREDSTATE OF WASHIN G TONEXP. 11/21/2019 WATER UTILITY agafour 05/16/2019AS-BUILTAS-BUILT1 BS 06/28 JM D-401713