Loading...
HomeMy WebLinkAboutzD-04017Set8645500170 8645500180 8645500190 8645500200 8645500210 8645500220 8645500230 8645500240 8645500250 8645600040 8645600030 8645500130 8645500140 8645500150 8645500160 LAKE Y O U N G S C T S E LA K E YO UNG S W AY S EBID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS COVER SHEET Sheet Index Sheet Number Sheet Number Sheet Title 1 C100 COVER SHEET 2 C101 STANDARD PLAN NOTES & CONSTRUCTION SEQUENCE 3 C200 TESC & DEMO PLAN 4 C201 GENERAL NOTES, CONSTRUCTION SEQUENCE NOTES, TESC & DEMO DETAILS 5 C300 PAVING & RESTORATION PLAN 6 C301 PAVING & RESTORATION DETAILS 7 C400 STORM DRAINAGE PLAN 8 C401 STORM DRAINAGE PROFILE & DETAILS 9 C402 STORM DRAINAGE DETAILS 10 C403 STORM DRAINAGE DETAILS 11 C500 WATER SYSTEM PLAN 12 C501 WATER SYSTEM DETAILS 13 C502 WATER SYSTEM DETAILS 14 SHT#1 TOPOGRAPHIC MAPPING GENERAL NOTE BASIS OF BEARING VERTICAL DATUM ALL RESIDENTIAL PROPERTY LINES SHOWN ARE APPROXIMATE BASED UPON CITY OF RENTON GIS MAPS WASHINGTON STATE PLANE COORDINATE SYSTEM NORTH ZONE (4601), NAD83(91), US SURVEY FOOT (GRID) N 65° 39' 57" E [SET MAG ( 1-ALLIANCE #102) TO SET MAG (1-ALLIANCE #100]] MEASUREMENT ARE US SURVEY FEET. NAVD88 NSITE MAP LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS VICINITY MAP N PROJECT LOCATION CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE DATE DATE SW: W: MAINT:JARE D MCDON A L DPRO FESSIONAL ENG I N E ERREGISTEREDSTATE OF WASHIN GTON05/09/19Richard W Marshall 05/09/2019 05/09/2019 WATER UTILITY agafour 05/16/2019 MICHAEL J A MES MIT C HELLPR O F ESSIONAL ENG I N E ERREGISTERE DSTATE OF WASHIN GT ONEXP. 11/21/2019AS-BUILTAS-BUILT1 BS 06/28 JM D-401701 BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS STANDARD PLAN NOTES & CONSTRUCTION SEQUENCE GENERAL PROJECT NOTES 1.ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS AND SPECIFICATIONS AND WASHINGTON STATE DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION", 2018 AND AS AMENDED BY THE CITY OF RENTON SUPPLEMENTAL SPECIFICATIONS AND THE CONTRACTSPECIAL PROVISIONS. 2.ALL WORK SHALL BE SUBJECT TO THE INSPECTION OF THE CITY ENGINEER OR DESIGNATED REPRESENTATIVE. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF TRAFFIC CONTROL PLANS.CONTRACTOR SHALL SUBMIT PLANS TO THE ENGINEER FOR APPROVAL PRIOR TO IMPLEMENTATION. EXCEPT FOR AS SPECIFICALLY NOTED, CONTRACTOR SHALL MAINTAIN A MINIMUM OF ONE LANE OPEN IN EACH DIRECTION AT ALL TIMES ON ALL ROADS WITHIN THE PROJECT AREA. 4.SITE CONSTRUCTION LIMITS (PRESERVATION LINES) COINCIDE WITH CITY RIGHT-OF-WAY UNLESS SHOWN OTHERWISE. 5.NO STAGING AREA IS PROVIDED TO THE CONTRACTOR. ALL STAGING AREAS SHALL BE ON A CONTRACTOR SECURED AREA. ALL TESC REQUIREMENTS APPLY TO THE CONTRACTOR'S OBTAINED STAGING AREA. CONSTRUCTION SEQUENCE NOTES 1.CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN, TESC PLAN, STAGING PLAN, UTILITY PROTECTION PLAN AND MATERIALS SUBMITTALS. 2.WATER SERVICES TO LOCAL RESIDENTS MUST REMAIN OPERATIONAL DURING CONSTRUCTION. TRANSFER OF SERVICES SHALL BE IMPLEMENTED PER NOTES ON SHEET C500-C503. CONTRACTOR SHALL SUBMIT A CONSTRUCTION SEQUENCE PLAN PRIOR TO CONSTRUCTION. 3.CONTRACTOR SHALL ATTEND A PRE CONSTRUCTION CONFERENCE. 4.CONTRACOTR SHALL IMPLEMENT DEWATERING SYSTEM IF NEEDED. 1 NOT TO SCALE EROSION AND SEDIMENT CONTROL STANDARD PLAN NOTES 2 NOT TO SCALE SURFACE WATER STANDARD PLAN NOTES WATER UTILITY GENERAL NOTES 1.ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS, THE CITY OF RENTON DEVELOPER EXTENSION AGREEMENT, AND WSDOT STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. 2.THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILYCOMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. 3.ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 OR 811 TO VERIFY UTILITY LOCATIONS A MINIMUM OF 72 HOURS BEFORE BEGINNING EXCAVATION. 4.ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND “CATALOG CUTS” FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON-SITE. 5.ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT-LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C151AND C104 STANDARDS. PIPE JOINTS SHALL BE PUSH-ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82 STANDARDS. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE-TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 6.ALL PIPE AND FITTINGS NOT TO BE DISINFECTED IN PLACE SHALL BE SWABBED WITH 1% AVAILABLE CHLORINE SOLUTION PRIOR TO INSTALLATION. 7.IN CUT AND FILL AREAS, THE WATER MAIN SHALL BE INSTALLED ONLY AFTER THE TRENCH AND ROADWAY SUBGRADE MATERIALS HAVE BEEN GRADED AND COMPACTED. 8.BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR SHALL PROVIDE CATCH BASIN INSERTS FOR ALL CATCH BASINS THAT WILL RECEIVE RUNOFF FROM THE PROJECT SITE. THE CONTRACTOR SHALL PERIODICALLY INSPECT THECONDITION OF ALL INSERTS AND REPLACE AS NECESSARY. 9.MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES (36") FOR PIPE DIAMETER OF 10 INCHES (10") OR LESS AND 48 INCHES (48") FOR PIPE DIAMETER OF 12 INCHES (12") AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 72 INCHES (72"). ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED ASNECESSARY TO CLEAR CONFLICTS AND TO PROVIDE 12-INCH (12") MINIMUM VERTICAL CLEARANCE BETWEEN UTILITIES AND MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 10.CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED, AND POURED INTO PLACE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS, AND BASE OF HYDRANTS. MEGALUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 11.ALL SERVICES SHALL BE 1-INCH BY 1-INCH (1" X 1") PER STANDARD DETAILS UNLESS OTHERWISE SPECIFIED. ADAPTERS FOR 3/4-INCH BY 5/8-INCH (3/4" X 5/8") METERS SHALL BE USED WHERE APPLICABLE. 12.UNIFORM PLUMBING CODE REQUIRES THE INSTALLATION OF PRIVATELY OWNED AND OPERATED PRESSURE REDUCING VALVES WHERE THE OPERATING PRESSURE EXCEEDS 80 PSI. 13.WHERE NEW UTILITY LINE CROSSES BELOW AN EXISTING ASBESTOS CONCRETE (AC) MAIN, THE AC PIPE SHALL BE REPLACED WITH DUCTILE IRON (DI) PIPE TO 3 FEET (3') PAST EACH SIDE OF THE TRENCH AS SHOWN ON CITY OF RENTON STANDARD PLAN 330.8. WRAP DI PIPE AND COUPLINGS WITH 8-MIL POLYETHYLENE CONFORMING TO AWWA C105.ALTERNATIVELY, WHERE DIRECTED BY THE ENGINEER, THE TRENCH SHALL BE BACKFILLED WITH CONTROLLED DENSITY FILL (CDF, FLOWABLE FILL) FROM BOTTOM OF TRENCH TO THE INVERT OF THE AC MAIN. 14.WHEN WORKING WITH ASBESTOS CEMENT PIPE, THE CONTRACTOR IS REQUIRED TO MAINTAIN WORKERS' EXPOSURE TO ASBESTOS MATERIAL AT OR BELOW THE LIMIT PRESCRIBED IN WAC 296-62-07705. 15.AVOID CROSSING WATER MAINS AT HIGHLY ACUTE ANGLES. THE SMALLEST ANGLE MEASURE BETWEEN UTILITIES SHOULD BE 45 TO 90 DEGREES. 16.WHERE WATER MAIN CROSSES ABOVE OR BELOW SANITARY SEWER, ONE FULL LENGTH OF WATER PIPE SHALL BE CENTERED FOR MAXIMUM JOINT SEPARATION. 17.AT POINTS WHERE EXISTING THRUST BLOCKING IS FOUND, MINIMUM CLEARANCE BETWEEN THE CONCRETE BLOCKING AND OTHER BURIED UTILITIES OR STRUCTURES SHALL BE 5 FEET (5'). 18.ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL, AND REMOVE PLUGS, CORPORATION STOPS, BLOW-OFF ASSEMBLIES, AND THRUST RESTRAINT/BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET-TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM-PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 19.NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSIPRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY A CITY OF RENTON UTILITY INSPECTOR. 20.AFTER DISINFECTING THE WATER MAIN, DISPOSE OF CHLORINATED WATER BY DISCHARGING TO THE NEAREST OPERATING SANITARY SEWER. 21.THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS A MINIMUM OF 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. WATER MAIN SHUTOFFS SHALL NOT BE SCHEDULED TO OCCUR ON FRIDAYS, CITY HOLIDAYS, NOR ON THE FIVE DAYS OR ONE DAY AFTER A CITY HOLIDAY, UNLESS APPROVED BY THE CITY OF RENTON WATER UTILITY. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE CLOCKING, AND COMPLETE SURFACE RESTORATION. SEE SECTION 3-08 CONNECTIONS TO EXISTING SYSTEM OF THE CITY OF RENTON GENERAL DESIGN AND CONSTRUCTION STANDARDS FOR WATER MAIN EXTENSIONS. 22.ABANDONMENT OF EXISTING WATER SERVICES SHALL BE ACCOMPLISHED AS FOLLOWS: A.REMOVE EXISTING SERVICE SADDLE FROM WATER MAIN AND REPLACE WITH NEW STAINLESS STEEL REPAIR BAND, ROMAC SS2, FORD SERVICE SADDLE FC101, CC THREADED SADDLE AND A CC THREAD BRASS PLUG, OR APPROVED EQUAL (WILL NOT BE REQUIRED WHEN WATER MAIN IS TO BE ABANDONED). B.REMOVE AND DISPOSE OF EXISTING SETTER AND METER BOX. C.CAP OR CRIMP (IF COPPER) EXISTING SERVICE LINE TO BE ABANDONED IN PLACE, EACH END. D.RETURN EXISTING METER TO CITY OF RENTON UTILITY INSPECTOR. 23.THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO REMOVE DUST AND DEBRIS FROM PAVEMENT AREAS AS DIRECTED BY THE ENGINEER. FLUSHING OF STREETS SHALL NOT BE PERMITTED WITHOUT PRIOR CITY APPROVAL. 24.TRENCH BACKFILL AND SURFACE RESTORATION OF EXISTING ASPHALT PAVEMENT SHALL BE AS REQUIRED BY THE RIGHT-OF-WAY USE PERMIT. 25.THE CONTRACTOR SHALL RESTORE THE RIGHT-OF-WAY AND EXISTING PUBLIC UTILITY EASEMENT(S) AFTER CONSTRUCTION TO A CONDITION EQUAL OR BETTER THAN CONDITION PRIOR TO ENTRY. THE CONTRACTOR SHALL FURNISH A SIGNED RELEASE FROM ALL AFFECTED PROPERTY OWNERS AFTER RESTORATION HAS BEEN COMPLETED. 26.WHEN WORK IS TO OCCUR IN EASEMENTS, THE CONTRACTOR SHALL NOTIFY THE EASEMENT GRANTOR AND THE CITYOF RENTON WATER UTILITY IN WRITING A MINIMUM OF 48 HOURS IN ADVANCE OF BEGINNING WORK (NOT INCLUDING WEEKENDS OR HOLIDAYS). FAILURE TO NOTIFY GRANTOR AND THE CITY OF RENTON WATER UTILITY WILL RESULT IN A STOP WORK ORDER BEING POSTED UNTIL THE MATTER IS RESOLVED TO THE SATISFACTION OF THE CITY OF RENTON WATER UTILITY. A WRITTEN RELEASE FROM THE EASEMENT GRANTOR SHALL BE FURNISHED TO THE CITY OF RENTON UTILITY INSPECTOR PRIOR TO PERMIT SIGN-OFF. 27.WORKERS MUST FOLLOW CONFINED SPACE REGULATIONS AND PROCEDURES WHEN ENTERING OR DOING WORK IN CITY OF RENTON OWNED CONFINED SPACES. 28.MANHOLES, CATCH BASINS AND VAULTS ARE CONSIDERED TO BE PERMIT-REQUIRED CONFINED SPACES. ENTRY INTO THESE SPACES SHALL BE IN ACCORDANCE WITH CHAPTER 296-809 WAC.JARED MCDON A LDPROFESSIONAL ENG IN EE RREGISTEREDSTATE OF WASHIN GTON05/09/19AS-BUILTAS-BUILT1 BS 06/28 JM D-401702 L A K E Y OU NG S W A Y S E LAKE Y O U N G S C T S E 8645500170 8645500180 8645500190 8645500200 8645500210 8645500220 8645500230 8645500240 8645500250 8645600040 8645600030 8645500130 8645500140 8645500150 8645500160 RIGHT OF WAY (TYPICAL) 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 5 4 4 4 44 4 4 4 4 2 4 4 4 4 4 6 6 4 4 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 99 9 8 8 8 3 3 2 1 2 8 5 5 3 2 2 10 4 5 11 12 4 14 13 4 2BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS N Feet1:240 4020010 TESC & DEMOLTION LEGEND CLEARING LIMITS INLET SEDIMENT PROTECTION SAWCUT: APPROX. 2" TO 3" DEPTH REMOVE SIDEWALK/DRIVEWAY REMOVE ASPHALT REMOVE CURB AND GUTTER KEY NOTES PRESERVE AND PROTECT EXISTING ASPHALT. PROVIDE NEAT SAWCUT. PRESERVE AND PROTECT EXISTING SIDEWALK AND/OR DRIVEWAY. PRESERVE AND PROTECT EXISTING UTILITY. PLUG PIPE(S) PER 2018 WSDOT STANDARD SPEC 7-08.3(4) PRESERVE AND PROTECT EXISTING TREE. KEYNOTE NOT APPLIED PRESERVE AND PROTECT EXISTING CURB AND GUTTER. ABANDON IN PLACE EXISTING WATER MAIN AND EXISTING WATER LATERALS UPON TRANSFER OF DOMESTIC SERVICES. SAWCUT TO BE DONE AT EXISTING JOINT. EXISTING NEWSPAPER STAND SHALL BE PERMANENTLY RELOCATED ACROSS THE STREET. SEE SHEET C300 FOR MORE INFORMATION. EXISTING MAILBOX STAND SHALL BE TEMPORARILY RELOCATED ACROSS THE STREET DURING CONSTRUCTION AND THEN RETURNED ONCE THE PROPOSED SIDEWALKS HAVE BEEN CONSTRUCTED. SEE SHEET C300 FOR MORE INFORMATION. EXISTING 2" BLOW-OFF ASSEMBLY TO BE ABANDONED, LID AND TOP SECTION OF VALVE BOX TO BE REMOVED. ENCASE ASSEMBLY WITH CDF. EXISTING SECTION OF CONCRETE SIDEWALK TO BE REMOVED AND REPLACED. EXISTING 4" GATE VALVE ON STEEL WATER MAIN, TO BE ABANDONED, LID AND TOP SECTION OF VALVE BOX TO BE REMOVED, UPON COMPLETION OF NEW WATER MAIN; SEE SHEET C500. ENCASE GATE VALVE WITH CDF. EXISTING SECTION OF ROADWAY TO BE REMOVED AND REPLACED. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 TESC & DEMOLITION NOTES 1.ALL EXISTING IMPROVEMENTS WITHIN CLEARING LIMITS SHALL BE DEMOLISHED AND REMOVED FROM THE SITE UNLESS OTHERWISE IDENTIFIED. 2.THE WORK UNDER THE CONTRACT INCLUDES ALL CLEARING NECESSARY TO COMPLETE ALL WORK ASSOCIATED WITH THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY REVIEW THE SITE CONDITIONS AND TO CORRELATE THESE OBSERVATIONS WITH THE PROJECT WORK AND INCLUDE ALL NECESSARY DEMOLITION, WHETHER SHOWN OR NOT, AND INCLUDE ALL SUCH COSTS IN THE SCOPE OF THE WORK. 3.CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED AND REMOVED MATERIALS FROM THE SITE UNLESS OTHERWISE NOTED. 4.ALL EXISTING WATER METER BOXES TO BE REMOVED UPON TRANSFER OF DOMESTIC SERVICES. 5.THE TEMPORARY EROSION AND SEDIMENT CONTROL (TESC) PLAN OUTLINED HEREIN IS CONCEPTUAL. THE CONTRACTOR IS REQUIRED TO SUBMIT A FINAL TEMPORARY WATER POLLUTION AND EROSION CONTROL PLAN IN ACCORDANCE WITH SPECIAL PROVISIONS SECTION 1-07.15. 6.THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION , MAINTENANCE, REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE APPLICANT/ESC SUPERVISOR UNTIL ALL CONSTRUCTION IS APPROVED. 7.THE ESC FACILITIES SHOWN ON THESE PLANS ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE BE UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND MODIFIED TO ACCOUNT FOR CHANGING SITE CONDITIONS (E.G., ADDITIONAL SUMP PUMPS, RELOCATION OF DITCHES AND SILT FENCES, ETC.). 8.THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/ESC SUPERVISOR AND MAINTAINED TO ENSURE CONTINUED PROPER FUNCTIONING. WRITTEN RECORDS SHALL BE KEPT OF WEEKLY REVIEWS OF THE ESC FACILITIES DURING THE WET SEASON (OCT. 1 TO APRIL 30) AND OF MONTHLY REVIEWS DURING THE DRY SEASON (MAY 1 TO SEPT. 30). 9.PUBLIC STREETS SHALL BE CLEANED ONCE PER DAY OR AS DIRECTED BY THE CITY. FLUSHING OF STREETS WITH WATER WILL NOT BE ALLOWED. 10.IN ACCORDANCE WITH DEPARTMENT OF ECOLOGY REQUIREMENTS, WASTEWATER FROM CEMENT CONCRETE MASONRY, OR ASPHALT CONCRETE CUTTING, OR POURING OPERATIONS SHALL NOT BE DISCHARGED INTO STORM DRAINAGE SYSTEMS OR SURFACE WATERS. IMPERVIOUS SURFACES CONTAMINATED WITH SEDIMENT FROM GRIT AND CUTTING, PLANNING OR PULVERIZING OPERATIONS SHALL BE VACUUM-CLEANED TO PREVENT CONTAMINANTS FROM ENTERING THE STORM DRAINAGE SYSTEM OR SURFACE WATERS. 11. ALL DEWATERING WATER AND RUNOFF WITHIN CONSTRUCTION AREAS SHALL BE TREATED VIA SEDIMENTATION, FILTRATION THROUGH VEGETATION IN APPROVED AREAS, OR PORTABLE FILTRATION SYSTEMS (UTILIZING TANKS AND FILTERS), AS NEEED, PRIOR TO DISCHARGE TO DOWNSTREAM SYSTEM IN ORDER TO MEET ALL APPLICABLE LOCAL, STATE AND FEDERAL WATER QUALITY REGULATIONS. CONTRACTOR MAY ALSO DISCHARGE TO THE SANITARY SEWER SYSTEM AFTER OBTAINING APPLICABLE PERMITS AND MEETING PRETREATMENT REQUIREMENTS. 1 C201 TESC & DEMO PLAN GENERAL NOTES 1.SEE DRAWING C300 FOR PAVING AND RESTORATION IMPROVEMENTS. SEE DRAWING C400 FOR STORM IMPROVEMENTS. SEE DRAWING C500 FOR WATER IMPROVEMENTS. 2.SEE DRAWING C101 FOR ADDITIONAL TESC NOTES 1 C101 JARE D MCDON A LDPROF ESSIONAL ENG I N E ERREGISTER EDSTATE OF WASHIN G TON05/09/19AS-BUILTAS-BUILT1 BS 06/28 JM D-401703 BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS 1 NOT TO SCALE CATCH BASIN INSERT GENERAL NOTES, CONSTRUCTION SEQUENCE NOTES, TESC & DEMO DETAILSJARED MCDON A L DPRO FESSIONAL ENG I N E ERREGISTEREDSTATE OF WASHIN GTON05/09/19AS-BUILTAS-BUILT1 BS 06/28 JM D-401704 8645500170 8645500180 8645500190 8645500200 8645500210 8645500220 8645500230 8645500240 8645500250 8645600040 8645600030 8645500130 8645500140 8645500150 8645500160 RIGHT OF WAY (TYPICAL) L A K E YO UN G S W A Y S E LAKE Y O U N G S C T S E -0+31 0+00 1+00 2+00 3+ 0 04+0 0 4+ 5 5 BP: -0+3 0 .79 EP: 4 + 5 4. 8 5 PI: 4+ 0 9. 8 5 PI: 0+00 .0 0 PC: 2+13 . 85 PT: 3 + 1 9. 8 5 CB#8 CB#7 CB#5 CB#6 CB#3 CB#2 S61° 1 0' 1 4. 0 0 " W 2 1 3 . 8 5 0'N3 2 ° 0 4 ' 08 . 00 "W 9 0 .0 00 ' S61° 10' 14.00"W 30.793'N32 ° 0 4 ' 0 8 .0 0 "W 45 . 000 ' L=106.00' R=70.00'Δ=86°45'44" N 173433.27 E 1306703.80 CGCG3 C301 CG CG CG3 C301 3 C301 3 C301 M MMMMMMM MMMMMMATCH EXISTING CROWN (TYPICAL) CB#9 CB#10 EX. CB#1 EX. MH#1 CG CG3 C301 CB#4 CO#1 CO#2 CO#3 CO#4 CO#5 EX. CB#2 18.00' RELOCATED NEWSPAPER STAND. FOUNDATION AND STAND TO BE INSTALLED IN-KIND TO EXISTING CONDITION. PROVIDE SMOOTH TRANSITION FROM BACK OF SIDEWALK TO EXISTING GROUND. MAXIMUM SLOPE ALLOWED IN VEGETATED AREA IS 33% RELOCATED MAILBOX STAND TO BE INSTALLED IN-KIND. SIDEWALK SHALL BE WIDENED AROUND MAILBOX TO PROVIDE A 4' MIN. CLEAR ZONE TO MEET ADA STANDARDS.4.89' EX. CB#3 RIGHT OF WAY CB#1BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS PAVING & RESTORATION PLAN N Feet 1" = 20' 4020010 PAVING & RESTORATION LEGEND RESTORED CEMENT CONCRETE TRAFFIC CURB AND GUTTER RESTORED CEMENT CONCRETE SIDEWALK RESTORED UTILITY PATCH FOR FLEXIBLE PAVEMENT RESTORED CONCRETE DRIVEWAY PAVING & RESTORATION NOTES 1.ALL PROPOSED WORK IS TO MATCH EXISTING GRADES UNLESS OTHERWISE NOTED. 2.LANDSCAPED AREAS IMPACTED BY CONSTRUCTION WORK SHALL BE FULLY RESTORED TO EXISTING CONDITION. 3.CENTERLINE ALIGNMENT LAYOUT SHOWN ON SHEET C300 TO BE USED FOR LOCATING PROPOSED UTILITES ON SHEETS C400 - C502 4.UNLESS NOTED OTHERWISE, RESTORE AND ADJUST ALL UTILITY CASTINGS TO FINAL GRADE. RESTORE PAVEMENT MARKINGS WITHIN AREAS DISTURBED BY CONSTRUCTION. 5.ALL EXISTING PAVEMENT MARKINGS THAT ARE DISTURBED ARE TO BE REPLACED IN KIND PER THE CONTRACT DOCUMENTS. 6.SEE DRAWING C400 FOR STORM IMPROVEMENTS. SEE DRAWING C500 FOR WATER IMPROVEMENTS. CG 1 C301 2 C301 4 C301 5 C301 6 C301 JARE D MCDON A L DPRO FESSIONAL ENG I N E ERREGISTEREDSTATE OF WASHIN GTON05/09/19AS-BUILTAS-BUILT1 BS 06/28 JM D-401705 BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS PAVING & RESTORATION DETAILS 1 NOT TO SCALE CEMENT CONCRETE TRAFFIC CURB AND GUTTER 2 NOT TO SCALE CEMENT CONCRETE SIDEWALK 3 NOT TO SCALE CEMENT CONCRETE CURB INSTALLATION AT CATCH BASINS 4 NOT TO SCALE CURB AND GUTTER REPLACEMENT DETAIL 5 NOT TO SCALE UTILITY PATCH FOR FLEXIBLE PAVEMENT 6 NOT TO SCALE RESTORED CONCRETE DRIVEWAY OMIT JOINT OMIT JOINT OMIT JOINT OMIT JOINT 4" 4" CEMENT CONCRETE CLASS 4000 CRUSHED SURFACING PER WSDOT 9-03.9(3) COMPACTED SUBGRADE JARE D MCDON A LDPROFESSIONAL ENG I N E ERREGISTERE DSTATE OF WASHIN GTON05/09/19AS-BUILTAS-BUILT1 BS 06/28 JM D-401706 L A K E YOU NG S W A Y S E LAKE Y O U N G S C T S E M MMMMMMM MMMMM-0+31 0+00 1+00 2+00 3 + 0 04+004+558645500170 8645500180 8645500190 8645500200 8645500210 8645500220 8645500230 8645500240 8645500250 8645600040 8645600030 8645500130 8645500140 8645500150 8645500160 RIGHT OF WAY (TYPICAL) CB#8 CB#7 CB#5 CB#6, BI-DIRECTIONAL VANED GRATE CB#3 CB#2 EX. MH#1 STA:2+55.98, 15.60'LT STA:3+08.39, 15.02'LT STA:3+86.97, 11.63'LT STA:3+85.72, 19.33'LT STA:3+93.05, 25.75'RT STA:4+33.68, 24.99'LT CB#9, SOLID LID CB#10, SOLID LID EX. CB#1 RIM: 367.44 IE: 365.9 8" (E) IE: 365.7 EX. 6" (W) STA:4+38.10, 33.03'LT STA:4+09.34, 43.00'LT 9 LF 8" C900 @ 1.00% MIN. 20 LF 8" C900 @ 1.00% MIN. 1 1 7 C402 CB#4, SOLID LID STA:3+23.07, 22.28'LT 10 LF 8" @ 1.00% MIN. 27 LF 8" @ 1.00% MIN. 24 LF 8" @ 1.00% MIN. CO#1 STA:2+61.13, 23.52'LT CO#2 STA:2+80.60, 23.44'LT CO#3 STA:2+98.25, 22.51'LT CO#4 STA:3+22.89, 13.41'LT CO#5 STA:4+10.00, 22.19'LT 8 LF 8" @ 1.00% MIN. 1 1 2 2 BP: -0+30 .79 EP: 4 + 5 4. 8 5 PI: 4 + 0 9. 8 5 PI : 0+00 .00PC: 2+13 .85 PT: 3 + 1 9. 8 5 EX. CB#2 RIM: 367.58 IE: 366.1 8" (SW) 33.35 LF 8" C900 @ 3.60% 16.07 LF 8" C900 @ 8.71% EX. CB#3 RIM: 367.36 IE: 365.9 8" (NE) 29.50 LF 8" C900 @ 4.75% 3 4 5 NEW 12" STORM NEW 12" STORM NEW 12" STORM NEW 12" C900 STORMNEW 12" STORM 5 C401 5 C401 5 C401 2 C402 2 C402 2 C402 2 C402 NEW 12" STORM CB#1 ROUND FRAME AND COVER STA:0+72.81, 2.40'RT 1 C403 6 1 375 380 385 390 375 380 385 390 -0+50388.19387.910+00387.76387.77CB#8 RIM: 388.22 IE: 385.55 8" (SE) IE: 383.68 8" (NE) CB#7 RIM: 387.46 IE: 384.50 12" (NE) IE: 384.83 8" (NW) CB#5 RIM: 387.76 IE: 384.15 12" (SW) IE: 384.15 12" (SE) IE: 384.15 12" (NE) CB#6 RIM: 387.53 IE: 384.53 12" (SW) 48 LF 8" @ 1.50% 8 LF 12" @ 4.51% 38 LF 12" C900 @ 1.00% EX. 4" WATER EST. LOCATION 8" WATER IE: 382.70 EX. 8" SEWER IE: 379.86 CO#5 RIM: 388.06 IE CONNECTION: 385.20 8" (SW) 1" WATER IE: 384.16 EX. WATER EST. LOCATION EX. 6" SEWER IE: 382.00 2 C401 PROPOSED GRADE (TO MATCH EXISTING) PROPOSED GRADEEXISTING GRADE EX. 4" WATER EST. LOCATION 1.00' MIN.BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS STORM DRAINAGE PLAN N Feet 1" = 20' 4020010 STORM DRAINAGE LEGEND STORM DRAIN CATCH BASIN TYPE I 48" CATCH BASIN TYPE II STORM CLEANOUT SUBSURFACE UNDERDRAIN KEY NOTES CONNECT EXISTING 3" STORM DRAIN(S) TO CATCH BASIN. CONNECT EXISTING 3" STORM DRAIN(S) TO NEW STORM SYSTEM. RELOCATED NEWSPAPER STAND, SEE SHEET C300 FOR MORE INFORMATION. RELOCATED MAILBOX STAND, SEE SHEET C300 FOR MORE INFORMATION. CONNECT NEW STORM DRAIN TO EXISTING MANHOLE. PROVIDE 1.00' MIN VERTICAL SEPARATION BETWEEN WATER AND STORM. 1 2 3 4 5 6 STORM DRAINAGE NOTES 1.SEE SHEET C101 FOR ADDITIONAL STORM NOTES. 2.ALL PIPES TO BE POLYPROPYLENE PIPE UNLESS OTHERWISE NOTED. 3.EXISTING OUT OF SERVICE WATER LATERALS IN CONFLICT WITH PROPOSED STORM ARE TO BE CUT AND PLUGGED OR REMOVED PER WSDOT STANDARD SPECIFICATION 7-08.3(4). SEE PROFILE FOR POTENTIAL LOCATIONS OF CONFLICT. 4.SEE SHEETS C500-C502 FOR WATER IMPROVEMENTS. 5.ALL EXISTING UTILITIES INTERSECTING WITH PROPOSED IMPROVEMENT SHALL BE VERIFIED HORIZONTALLY AND VERTICALLY PRIOR TO CONSTRUCTION. CONTRACTOR TO PROVIDE THE PROJECT MANAGER WITH A PLAN SHOWING LOCATION OF EXISTING UTILITIES THAT INTERSECT WITH PROPOSED IMPROVEMENTS. 6.SEE STORM PROFILES FOR ADDITIONAL INFORMATION. 7.CATCH BASINS SHALL BE INSTALLED PER 8.ALL GRATES SHALL BE RECTANGULAR VANED GRATES UNLESS OTHERWISE NOTED. 9.STORM SEWER LENGTHS ARE MEASURED BETWEEN CENTERS OF MANHOLES AND CATCH BASINS UNLESS OTHERWISE NOTED. 10.EXCEPT AS OTHERWISE NOTED, CATCH BASIN AND MANHOLE RIM ELEVATIONS GIVEN WITHIN PAVED AREAS ARE APPROXIMATED. FINAL ELEVATIONS SHALL MATCH FINAL GRADE. 11.FOR BEDDING AND BACKFILLING AROUND EXISTING OR NEW UTILITIES USE CDF WHERE STANDARD METHODS DO NOT PERMIT COMPACTION REQUIREMENTS TO BE MET, AS SHOWN ON THE DWGS, OR AS DIRECTED BY ENGINEER. 12.TEMPORARY SHORING IS REQUIRED FOR ALL STORM DRAIN WORK AND ASSOCIATED MANHOLES. MINIMUM SHORING TECHNIQUE SHALL BE USE OF TRENCH BOX. SPECIAL SHORING TECHNIQUES ARE REQUIRED WHERE WORKING IN CLOSE PROXIMITY TO UTILITIES. SEE SPECIAL PROVISIONS SECTION 7-08. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL SUBMIT TO CITY PROJECT MANAGER, A SHORING AND UTILITIES PROTECTION PLAN. 1 C401 3 C402 8 C402 4 C402 2 C401 1 SCALE: 1"=20'H, 1"=5'V STORM PROFILE CB#6 TO CB#8 1 C402 2 C101 1 C400 1 C401 1 C400 2 C403 384.75 1.58% 387.99387.63 384.43 384.38 4.45% 0.4%46 388.00 384.26 384.26 4+31.1 26.8 3+91.1 23.4 4+11.1 43.8 366.26 0+74.1 2.8 19.5 12.0 3+23.4 19.4 3+09.71 2+95.2 28.7 2+82.90 26.9 2+62.8 23.6 2+56.5 CO#4 RIM: 389.70 IE: 385.65 8" (NE)AS-BUILTAS-BUILT1 BS 06/28 JM D-401707 350 355 360 365 370 375 380 385 390 350 355 360 365 370 375 380 385 390 CB#5 RIM: 387.76 IE: 384.15 12" (SW) IE: 384.15 12" (SE) IE: 384.15 12" (NE) CB#3 RIM: 386.95 IE: 383.34 12" (NW) IE: 383.34 12" (SE) CB#2 RIM: 386.82 IE: 383.05 8" (SW) IE: 382.72 12" (NW) IE: 382.72 12" (NE) EX. MH#1 RIM: 367.93 IE: 361.20 12" (SW) IE: 364.7 8" (NW) IE: 364.7 8" (NE) IE: 364.5 8" (SW) IE: 355.2 EX. 60" (NW) IE: 354.9 EX. 60" (SE) 190 LF 12" @ 9.41% 81 LF 12" @ 1.00% 62 LF 12" @ 1.00% 0+00367.93368.150+50368.93370.541+00373.00375.961+50379.02382.002+00384.60386.282+50386.75387.073+00387.24386.953+50387.21387.434+00387.70EX. 8" SEWER IE: 360.16 EX. GAS EX. WATER EST. LOCATION 1" WATER IE: 370.00 EX. POWER EST. LOCATION EX. COMM EST. LOCATION EX. WATER EST. LOCATION 1" WATER IE: 378.79 1" WATER IE: 382.99 EX. WATER EST. LOCATION EX. 8" SEWER IE: 377.10 1" WATER IE: 383.77 EX. WATER EST. LOCATION 1" WATER IE: 382.37 EX. WATER EST. LOCATION EX. WATER EST. LOCATION 1" WATER IE: 382.47 PROPOSED GRADE (TO MATCH EXISTING) PROPOSED GRADEEXISTING GRADE EX. WATER EST. LOCATION CO#4 RIM: 387.13 IE CONNECTION: 383.68 8" (SW) 73 LF 12" @ 5.05% CB#1 48" CATCH BASIN TYPE II RIM: 370.38 IE: 364.88 12" (SW) IE: 364.88 12" (NE)BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS STORM DRAINAGE PROFILE & DETAILS 3 NOT TO SCALE TRENCH AND BACKFILL 4 NOT TO SCALE PIPE ZONE BEDDING & COMPACTION 2 NOT TO SCALE SUBSURFACE UNDERDRAIN 1 SCALE: 1"=20'H, 1"=5'V STORM PROFILE EX. MH#1 TO CB#5 6 NOT TO SCALE UNDERDRAIN AGGREGATE A A SECTION A - A UNDERDRAIN AGGREGATE, SEE NOTE 1 SLOTTED UNDERDRAIN PIPE, SEE NOTE 2 CB#7 SEE PLAN AND PROFILE FOR MORE INFORMAITON CB#8 SEE PLAN AND PROFILE FOR MORE INFORMAITON SURFACE RESTORATION PER SHEET C300 SUBGRADE UNDERDRAIN AGGREGATE 2.5' MIN. WIDTH UNDERDRAIN AGGREGATE 2' MIN. DEPTH CENTERED ON PIPE NOTES 1.UNDERDRAIN AGGREGATE SHALL MEET STD. PLAN 262.60 2.UNDERDRAIN TO BE 8" SLOTTED PVC PER ASTM D1785 SCH 40. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS OF THE PIPE AND BE 0.04 TO 0.069 INCHES BY 1 INCH LONG AND BE SPACED 0.25 INCHES APART (SPACED LONGITUDINALLY). SLOTS SHOULD BE ARRANGED IN FOUR ROWS SPACED ON 45-DEGREE CENTERS AND COVER 12 OF THE CIRCUMFERENCE OF THE PIPE. SLOPE PIPE PER PLAN. 3.LOCATE UNDERDRAIN BELOW STRUCTURAL PAVEMENT BASE DEPTH. 6 C401 5 NOT TO SCALE RECTANGULAR SOLID METAL COVER 365.00 365.00 5.21% 9.26% 1.10% 1.10% 382.60 382.60 382.67 386.90 387.03 383.28 383.28 387.99 AS-BUILTAS-BUILT1 BS 06/28 JM D-401708 BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS STORM DRAINAGE DETAILS 3 NOT TO SCALE CATCH BASIN INSTALLATION 4 NOT TO SCALE CATCH BASIN TYPE 1 5 NOT TO SCALE PREFABRICATED LADDER & RECTANGULAR ADJUSTMENT 6 NOT TO SCALE RECTANGULAR FRAME 7 NOT TO SCALE RECTANGULAR BI-DIRECTIONAL VANED GRATE 8 NOT TO SCALE RECTANGULAR VANED GRATE 1 NOT TO SCALE STORM CLEANOUT 2 NOT TO SCALE STORM UNDERDRAIN JARED MCDON A LDPRO FESSIONAL ENG IN EE RREGISTEREDSTATE OF WASHIN GTON05/09/19AS-BUILTAS-BUILT1 BS 06/28 JM D-401709 BID SETSWP - 27 - 4017LAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS STORM DRAINAGE DETAILS 1 NOT TO SCALE STORM ROUND FRAME AND COVER 2 NOT TO SCALE CATCH BASIN TYPE II JARE D MCDON A L DPRO FESSIONAL ENG I N E ERREGISTEREDSTATE OF WASHIN GTON05/09/19AS-BUILTAS-BUILT1 BS 06/28 JM D-401710 8645500170 8645500180 8645500190 8645500200 8645500210 8645500220 8645500230 8645500240 8645500250 8645600040 8645600030 8645500130 8645500140 8645500150 8645500160 RIGHT OF WAY (TYPICAL) L A K E YOUNG S W A Y S E LAKE Y O U N G S C T S E M MMMMMMM MMMMM-0+31 0+00 1+00 2+00 3 + 0 04+004+55STA:2+52.72, 23.40'LT STA:4+16.18, 40.86'RT (1) FIRE HYDRANT ASSEMBLY WITH 6' X 6' X 6" CONCRETE PAD STA:2+40.92, 4.68'RT (1) 45° BEND (MJ X MJ) WITH THRUST BLOCKING STA:2+92.77, 4.60'RT (1) 22.5° BEND (MJ X MJ) WITH THRUST BLOCKING (E) SANITARY SEWER PIPE (TYP.) (E) 4" STEEL WATER MAIN, TO BE ABANDONED IN PLACE (E) 4" STEEL WATER MAIN, TO BE ABANDONED IN PLACE STA:-0+12.57, 11.46'R POC (1) 12"X8" CUT-IN TEE (MJ X FL) (1) 12" GATE VALVE (MJ X MJ) (1) 8" GATE VALVE (FL X MJ) (3) 12" SPOOL (2) 12" TRANSITION COUPLING WITH THRUST BLOCKING STA:4+16.09, 9.07'RT (1) 8" X 6" TEE (MJ X FL) (1) 6" GATE VALVE (FL X MJ) WITH THRUST BLOCKING STA:1+05.79, 22.74'LT STA:1+73.61, 23.32'LT STA:2+19.15, 23.08'LT STA:2+21.84, 22.48'RT STA:3+80.11, 23.65'RT STA:4+42.01, 25.57'RT STA:4+42.97, 24.37'RT STA:3+27.19, 24.12'LT STA:4+14.31, 41.82'LT STA:4+42.36, 27.12'LT STA:0+44.38, 22.85'RT 2 STA:3+17.94, 23.29'LT 2 2 2 2 2 2 2 2 2 2 2 2 3 1 248 L F 8" DI PI P E 47 LF 8" DI P I P E120 LF8" D I P IPE (E) 2" STEEL PIPE, TO BE ABANDONED IN PLACE (E) 12" STEEL CONCRETE-LINED PIPE WATER MAIN (590 PRESSURE ZONE) (E) 12" STEEL CONCRETE-LINED PIPE WATER MAIN (590 PRESSURE ZONE) (E) SANITARY SEWER PIPE (TYP.) PROPOSED STORM DRAIN PIPE (TYP.)PROPOSED STORM DRAIN PIPE (TYP.) (E) UNDERGROUND TELECOMMUNICATIONS (E) UNDERGROUND ELECTRIC UTILITY (E) 2" BLOWOFF ASSEMBLY TO BE ABANDONED (E) 6" STEEL WATER MAIN, ABANDONED13' 12' (E) 6" STEEL WATER MAIN, ABANDONED 5.2' (E) FIRE HYDRANT ASSEMBLY 9' 14' 13' 9.5' (E) 12" STEEL WATER MAIN, ABANDONED (E) 12" STEEL WATER MAIN, ABANDONED (E) 6" STEEL WATER MAIN, ABANDONED 4 4 4 4 4 4 3' 5' (E) FENCE, PROTECT IN PLACE (E) FENCE, REMOVE AND RESTORE AS NEEDED 5 6(1) 4" PLUG (MJ) (1) 4" CAP 8 7 JOINT RESTRAINT SYSTEM BEGIN APPROX. STA 2+01.00 END APPROX. STA 3+32.00 SEE GENERAL NOTE 6BID SETLAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS 1.WATER MAIN SHALL BE CLASS 52 DUCTILE IRON PIPE WITH POLYETHYLENE ENCASEMENT. 2.WATER MAIN SHALL BE INSTALLED WITH NO LESS THAN THREE FEET (3') AND NO MORE THAN SIX FEET (6') COVER FROM FINISHED GRADE TO TOP OF PIPE. WATER MAIN SHALL BE INSTALLED NO LESS THAN SIX INCHES (6") ABOVE NEW AND EXISTING STORM DRAIN AND SANITARY SEWER PIPES, MEASURED FROM EDGE OF PIPE TO EDGE OF PIPE. 3.NEW WATER MAIN SHALL BE INSTALLED NO LESS THAN FOUR FEET (4') HORIZONTALLY FROM EXISTING (TO BE ABANDONED) WATER MAIN. 4.INSTALLATION OF CUT-IN TEE SHALL BE FACILITATED BY SHUTTING THE WATER VALVES (TO BE DONE BY CITY FORCES) AT THE FOLLOWING LOCATIONS: 4.1.APPROXIMATELY 405' NORTHWEST OF THE POINT OF CONNECTION, IN LAKE YOUNGS WAY SE, SOUTH OF THE INTERSECTION WITH SE ROYAL HILLS DRIVE. 4.2.APPROXIMATELY 245' SOUTHEAST OF THE POINT OF CONNECTION, AT THE NORTHERN CORNER OF THE INTERSECTION OF LAKE YOUNGS WAY SE AND SE 16TH STREET. 5.TRENCH REQUIREMENTS SHOWN ON DETAIL 2, SHEET C301. 6.RESTRAINT SYSTEM FOR PUSH-ON PIPES SHALL BE INSTALLED AT THE LOCATIONS INDICATED AND SHALL BE HARNESS-TYPE, MEGALUG SERIES 1700, ROMAC 600 SERIES, OR EQUAL. RESTRAINT SYSTEM SHALL BE INSTALLED A MINIMUM TWO JOINTS OR 36' FROM EACH FITTING. 7.ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE WEDGE-TYPE RESTRAINED RETAINER GLANDS EQUAL TO MEGALUG SERIES 1100 OR ROMAC ROMAGRIP. 8.INSTALL ALL CONCRETE THRUST BLOCKING PER CITY STANDARD PLANS; SEE DETAILS 1-3, SHEET C502. 9.INSTALLATION OF NEW WATER SERVICES SHALL BE PERFORMED VIA HOLE HOG METHOD BENEATH EXISTING SIDEWALK. 10.CONSTRUCTION AND TRANSFER OF DOMESTIC SERVICES SHALL BE PERFORMED SUCH THAT EACH SERVICE IS MINIMALLY DISRUPTED. 11.TRANSFER OF WATER SERVICES TO BE PERFORMED BY CONTRACTOR; METER SETTING TO BE PERFORMED BY CITY FORCES. 12.CONTRACTOR SHALL RESTORE DISTURBED AREAS TO ORIGINAL CONDITION OR BETTER. WATER UTILITY PLAN N KEY NOTES POINT OF CONNECTION TO EXISTING WATER MAIN. INSTALL 1" DOMESTIC WATER SERVICE AND METER BOX AND CONNECT TO EXISTING PRIVATE SERVICE LINE BEHIND ROW LINE. CITY FORCES TO REINSTALL EXISTING AMI METER TO NEW SETTER. REMOVE AND SALVAGE EXISTING METER BOX AND SETTER. INSTALL FIRE HYDRANT ASSEMBLY. EXISTING, ABANDONED STEEL WATER MAIN TO BE CUT AND CAPPED AS NEEDED FOR CONSTRUCTION OF NEW WATER MAIN AND STORM DRAIN IMPROVEMENTS. INSTALL WATER MAIN USING PIPELINE DEFLECTION PER MANUFACTURER GUIDELINES TO ACHIEVE DESIGN ALIGNMENT. UPON FINAL CONNECTION OF NEW WATER MAIN TO EXISTING SYSTEM AND TRANSFER OF ALL DOMESTIC SERVICES, CUT AND CAP EXISTING 4" STEEL WATER MAIN AND INSTALL 4" MJ PLUG ON EXISTING GATE VALVE. REMOVE LID AND TOP SECTION OF VALVE BOX. EXISTING SECTION OF ROADWAY TO BE REMOVED AND REPLACED. EXISTING 2" BLOW-OFF ASSEMBLY TO BE ABANDONED, LID AND TOP SECTION OF VALVE BOX TO BE REMOVED. EXISTING SECTION OF CONCRETE SIDEWALK TO BE REMOVED AND REPLACED. POLYPIG STATION. 1 2 3 4 5 6 7 8 GENERAL NOTES Feet 1" = 20' 4020010WTR - 27 - 40171 C501 5 C502 3 C501 2 C501 5 C501 4+11.6, 10.0' RT 4+13.4, 41.2' RT -0+11.7, 10.1' RTAS-BUILTAS-BUILT1 BS 06/28 JM D-401711 0+00 STA:-0+12.57, 11.46'RT POC (1) 12"X8" CUT-IN TEE (MJ X FL) (1) 12" GATE VALVE (MJ X MJ) (1) 8" GATE VALVE (FL X MJ) (3) 12" SPOOL (2) 12" TRANSITION COUPLING WITH THRUST BLOCKING NOTE: FIELD VERIFY OD OF STEEL PIPE PRIOR TO ORDERING TRANSITION COUPLING 0+00BID SETLAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS WATER UTILITY DETAILS 10' ± FINAL CONNECTION TESTING CONNECTION (1) 8" CROSS (MJ x FL) (1) BLIND FLANGE ON TOP WITH 2" TAP & 2" PLUG (1) BLIND FLANGE ON BOTTOM WITH TEMPORARY BLOCKING (1) 8" SPOOL (1) PLUG (MJ) WITH 2" TAP & 2" TEMPORARY BLOWOFF WITH TEMPORARY BLOCKING UPON COMPLETION OF TESTING, CLEANING BY POLYPIG, AND DISINFECTION, REMOVE CROSS, TEMPORARY BLOCKING, AND TEMPORARY BLOW-OFF ASSEMBLY; CONNECT TO EXISTING WATER LINE WITH SLEEVES (MJ) AND DI SPOOLS; FINAL CONNECTION BY CITY FORCES 8" DI LENGTH AS NEEDEDWTR - 27 - 4017(E) 12" X 4" STEEL TEE (E) 12" STEEL CONCRETE-LINED WATER MAIN (E) 4" STEEL WATER MAIN, TO BE ABANDONED (E) STORM DRAIN PIPE (E) SANITARY SEWER PIPE (E) 12" STEEL CONCRETE-LINED WATER MAINLAKE YOUNGS WAY SELAKE YOUNGS WAY SE(E) 12" STEEL WATER MAIN, ABANDONED (E) 6" STEEL WATER MAIN, ABANDONED (E) 12" STEEL WATER MAIN, ABANDONED N 3' MIN. COVER (10" DIAMETER AND UNDER)4' MIN. COVER (12" DIAMETER AND OVER) TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE INSTALL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG NEW WATER MAIN POLYPIG FINISHED GRADE ELEVATION VERTICAL CROSS FOR POLYPIGGING STATION: (1) 8" X 8" VERTICAL CROSS (MJ x FL) (1) BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW-OFF ASSEMBLY (REMOVE BLOW-OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING POLYPIG) (1) BLIND FLANGE ON BOTTOM OF CROSS (1) PLUG (MJ) ON END OF CROSS WITH TEMPORARY CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN I F HG E K L B M A J J 1' 4" 2'1' 2"-4" PER MANUFACTURER'SRECOMMENDATION 1' ASPHALT CONCRETE PAD 2' DIA. X 2" THICK ROADWAY OR NEAREST CHANNELIZATION36" MIN. COVER1' MIN. MAIN D C 1' MIN. A FIRE HYDRANT SHALL BE COMPRESSION TYPE SUCH AS CLOW MEDALLION, MUELLER SUPER CENTURION 250, AND AMERICAN DARLING B-62-B WITH 6" MECHANICAL JOINT INLET WITH LUGS, 5-1/4" MAIN VALVE OPENING, TWO 2-1/2" HOSE CONNECTIONS, NATIONAL STANDARD THREADS, 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON REGIONAL FIRE AUTHORITY. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT. TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT, VALVE NUT EXTENSION AS REQUIRED. SEE DETAIL 6, SHEET C502. 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT. MEGALUG JOINT RESTRAINT OR 2-3/4" CORTEN STEEL TIE RODS FOR DISTANCES OVER ONE PIPE LENGTH. 1/2 CUBIC YARD OF 1-1/4" WASHED DRAIN ROCK 1' ABOVE BOOT FLANGE. PLACE 8 MIL POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. 16" X 8" X 4" MIN. SIZE CONCRETE BLOCK UNDER HYDRANT AND VALVE. CONCRETE BLOCKING PER DETAILS 1-3, SHEET C502.. 3' MIN. RADIUS OF LEVEL GROUND AROUND OUTSIDE OF HYDRANT. 6' X 6' X 6" THICK CONCRETE PAD AROUND HYDRANT. FINISH TO MATCH SIDEWALK. RAISED PAVEMENT MARKER TYPE 88-A STIMSONITE TWO-WAY BLUE REFLECTIVE, PER DETAIL 5, SHEET C502. 4.875" X 5" STORZ ADAPTER. B C D E F G H I J K L M AA VALVE BOX LID WITH EARS IN DIRECTION OF WATER MAIN AND CAST WITH WORD "WATER" 2-PIECE CASE IRON VALVEBOX, RICH-SEATTLE TYPE OR OLYMPIC FOUNDRY 1/8" MIN. THICKNESS 1" STEEL LENGTH AS REQUIRED 4 14" DIA. 1/8" MIN. THICKNESS WHITE POST SEE DETAIL INSTALL 8" THICK HMA COLLARFOR VALVES IN PAVED AREAS PER STD PLAN 106 OR 6" THICK, 3' X 3' CONCRETE PAD IN UNPAVED AREAS 12" MIN.18" MAX. VALVE OPERATION NUT EXTENSION NOTES: EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN 3 FEET (3') BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF 1 FOOT (1') LONG. ONLY ONE EXTENSION TO BE USED PERVALVE. ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, AND PAINTED WITH TWO COATS OF METAL PAINT. VALVE MARKER NOTES: VALVE MARKERS SHALL BE EQUAL TO CARSONITEUTILITY MARKER. VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS. SECTION A–A VALVE OPERATING NUT EXTENSION VALVE MARKER POST 2 14" INSIDE MEASUREMENT 2 14" DEPTH 2" SQUARE OPERATING NUT 12" OF WATER MAIN PLAN VIEW 3 34" 38" 24" 62" 3" MIN. WIDTH HYDRANT MARKERS TWO LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LINE) ON SIDE STREETS WHERE THE HYDRANT IS WITHIN 20' OF A MAIN TRAVELED STREET, THE MARKER IS TO BE INSTALLED ON THAT MAIN STREET FOUR LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) FIVE LANE ROAD OFFSET MARKER TO INDICATE WHICH SIDE OF STREET HYDRANT IS ON (4" FROM DOTS OR PAINTED LANE DIVIDER) RAISED PAVMENT MARKER TYPE 88-A STIMSONITE TWO-WAY BLUE REFLECTIVE MARKER MARKER MARKER MARKERMARKER 0.7" 4" 1 NOT TO SCALE CONNECTION TO WATER MAIN 2 NOT TO SCALE HYDRANT MARKER LAYOUT 4 NOT TO SCALE VALVE BOX & OPERATING NUT EXTENSION 5 NOT TO SCALE POLYPIG STATION 3 NOT TO SCALE FIRE HYDRANT ASSEMBLY UPON FINAL CONNECTION OF NEW WATER MAIN TO EXISTING SYSTEM, CUT AND CAP EXISTING 4" STEEL WATER MAIN AND INSTALL (1) 4" MJ PLUG (1) 4" CAP MICHAEL J A MES MIT CHELLPROF ESSIONAL ENG IN EE RREGISTEREDSTATE OF WASHIN G TONEXP. 11/21/2019 WATER UTILITY agafour 05/16/2019AS-BUILTAS-BUILT1 BS 06/28 JM D-401712 BID SETLAKE YOUNGS CT SE STORM & WATER IMPROVEMENTS WATER UTILITY DETAILSWTR - 27 - 401790° BEND SAFE BEARING LOADS IN LB./SQ.FT. THE SAFE BEARING LOADS GIVEN IN THE FOLLOWING TABLE ARE FOR HORIZONTAL THRUSTS WHEN THE DEPTH OF COVER OVER THE PIPE EXCEEDS TWO FEET (2'). SOIL * MUCK, PEAT, ETC. SOFT CLAY SAND SAND & GRAVELSAND & GRAVEL, CEMENTED WITH CLAY HARD SHALE SAFE BEARING LOADS IN LB./SQ.FT. 0 1,000 2,000 3,000 4,000 10,000 * IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATIONS OR BY REMOVAL OF MUCK OR PEAT AND REPLACEMENT WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. NOTES: 1.SQUARE FEET OF CONCRETE THRUSTS - BLOCK AREA BASED ON SAFE BEARING LOAD OF 2,000/(3,000) POUNDS PER SQUARE FOOT. 2.AREAS MUST BE ADJUSTED FOR OTHER SIZE PIPE, PRESSURES, AND SOIL CONDITIONS. 3.CONCRETE BLOCKING SHALL BE CAST IN PLACE AND HAVE MINIMUM 1/4 SQUARE FOOT BEARING AGAINST THE FITTING. 4.BLOCK SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. 5.CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. PRESSURE PSI A B C D E X (100 PSI)PIPE SIZE 4"200300 2/(1) 3/(2) 1/(NONE) 2/(2)NONENONE NONE1/(NONE) 2/(1) 1/(NONE) 1/(1) 6"200 300 4/(3) 6/(4) 8"200 300 7/(5) 11/(8) 10"200 275 11/(8) 16/(11) 16/(11) 24/(16)12"200 250 14"200 250 16"200 225 18"200 20"200 24"200 3/(2) 4/(3) 5/(3) 8/(5) 8/(6) 11/(7) 3/(1) 3/(2) 4/(3) 6/(4) 6/(4) 9/(6) 1/(1) 2/(1) 2/(2) 3/(2) 3/(2) 5/(3) 1/(NONE) 1/(NONE) 1/(1) 2/(1) 2/(1) 3/(2) NONE 3/(2) 4/(3) 5/(4)11/(8) 17/(11) 9/(6) 13/(9) 5/(3) 7/(5) 3/(2) 4/(3) 22/(13) 33/(22)7/(6)16/(11) 23/(16) 12/(8) 18/(12) 6/(4) 9/(6) 3/(2) 5/(3) 29/(19) 32/(21)10/(7)21/(14) 23/(16) 16/(11) 17/(12) 8/(6) 9/(6) 5/(3) 5/(3) 13/(9) 16/(11) 23/(16) 5/(4) 7/(4) 9/(6) 10/(7) 13/(8) 18/(12) 20/(13) 24/(16) 35/(23) 26/(17) 32/(21) 46/(30) 36/(24) 45/(29) 64/(43) MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL, IN SQUARE FEET THRUST BLOCK - TABLE CAP 22 1/2° BEND 45° BEND TEE 11 1/4° BEND A B C B D E VERTICAL BEND CU FT 11 1/4°* A D LV BPIPESIZE * * 16 2.5'3/4"2.0' * * 33 86 3.2' 4.4' * 13 64 141 4.0' 3.5'1"5.2' * 2.3' 22 1/2° 45° 90° 11 1/4° 22 1/2° 45° 90° 11 1/4° 22 1/2° 45° 90° 11 1/4° 22 1/2° 45° 90° 4" 6" 8" 10" 12" 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 3/4"2.0' 2.3' 3.5' 13 43 * * 20 111 206 4.8' 5.9' 2.7' 1 1/8"4.0' 11 1/4° 22 1/2° 45° 90° VERTICAL BLOCKING SIZE W/RESTRAINED JOINTSSOIL TYPE = COHESIVE GRANULAR [GC+SC] SAND, GRAVEL, CLAY MIXTURE NOTES: 1.NO CHANGE IN PIPE DIRECTION OR DIAMETER SHALL OCCUR WITHIN 36 FEET OF THE VERTICAL BEND. BENDS, TEES, REDUCERS, ETC., BEYOND THE 36-FOOT LIMIT SHALL BE RESTRAINED BY STANDARD CONCRETE BLOCKING PER DETAILS 2 & 3, SHEET C502. 2.CONCRETE BLOCKING SIZES BASED ON: - 36 FEET OF PIPE RESTRAINED EACH SIDE OF BEND. - THRUST BLOCK AREAS BASED ON SAFE BEARING LOAD OF 1,000 PSF. - 2,500 PSI CONCRETE. - MINIMUM 3 FEET (3') OF COVER. - PIPE THRUST BASED ON 200 PSI PRESSURE. - PIPE AND FITTINGS ENCASED IN POLYETHYLENE. - VERTICAL BLOCK SIZE BASED ON CONCRETE WEIGHT OF 150 PCF. - TRENCH CONDITIONS BASED ON TYPE 2, FLAT BOTTOM TRENCH WITH LIGHTLY CONSOLIDATED BACKFILL, PER ANSI/AWWA C150/A21.50. - FACTOR OF SAFETY = 1.5. - SOIL FRICTIONAL RESISTANCE BASED ON COHESIVE GRANULAR SOIL TYPE (GC+SC), SAND, GRAVEL, CLAY MIXTURE. 3.BLOCKING DESIGN MUST BE ADJUSTED FOR OTHER SIZE PIPE, PRESSURES, AND SOIL CONDITIONS. 4.PIPE CLAMP (HOT DIPPED GALVANIZED), RODS (STAINLESS STEEL ALL-THREAD 316SS). SEE DETAIL 4, SHEET C502. 5.LINE SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100 FEET OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM COVER OF 3 FEET (3') OVER PIPE. 6.90° VERTICAL BENDS SHALL ONLY BE INSTALLED WHERE GIVEN PRIOR APPROVAL BY THE UTILITY. 7.BACKFILL TRENCH BEYOND 90° VERTICAL BLOCK WITH CRUSHED SURFACING TOP COURSE MATERIAL COMPACTED TO 95% MAXIMUM DENSITY. CRUSHED BACKFILL SHALL EXTEND 20 FEET BEYOND BLOCK OR TO FIRM BEARING TRENCH WALL, WHICHEVER IS LESS. 8.LEAVE BLOCK OPEN OR SHEETED 24 HOURS MINIMUM. 9.MEGALUG FITTINGS. A L A D PIPE CLAMPS & RODS (SEE NOTE 4) 45° SEE NOTE 9 (TYPICAL) VERTICAL BLOCKING FOR 90° BENDS (SEE NOTE 6) L A L A COMPACTED BACKFILL (SEE NOTE 7) D PIPE CLAMPS & RODS (SEE NOTE 4) 90° L A L A UNDISTURBEDEARTHD PIPE CLAMPS & RODS (SEE NOTE 4) SEE NOTE 9 (TYPICAL) L VERTICAL BLOCKING FOR 11 1/4° & 22 1/2° BENDS D PIPE CLAMP & RODS (SEE NOTE 4) A L A UNDISTURBEDEARTHD 45° SEE NOTE 3 (TYPICAL) L VERTICAL BLOCKING FOR 45° BENDS VERTICAL BEND A L A UNDISTURBEDEARTHD L VERTICAL BLOCKING FOR 11 1/4° & 22 1/2° BENDS D PIPE CLAMP & RODS (SEE NOTE 4) NOTES: 1.CONCRETE BLOCKING BASED ON 200 PSI PRESSURE AND 2,500 PSI CONCRETE. 2.LEAVE CLOCK OPEN OR SHEETED 24 HOURS MINIMUM. 3.JOINT RESTRAINT, SEE APPROVED MATERIALS LIST. 4.PIPE CLAMP (HOT DIPPED GALVANIZED), RODS (STAINLESS STEEL ALL-THREAD 316SS), SEE DETAIL 4, SHEET C502. CU FT 11 1/4°8 A D LV BPIPE SIZE 11 17 22 1/2° 30° 11 1/4° 22 1/2° 30° 4" 6" 8" 7/8"3.0' 1 1/4"4.0' 91 225 330 6.1' 6.9' 4.5' 1 3/8"4.5' 11 1/4° 22 1/2° 30° VERTICAL BLOCKING FOR 11 1/4°, 22 1/2°, & 30° BENDS 2.0' 2.2' 2.6' 3/4" 1.5' 2.0' 11 1/4°11 25 41 22 1/2° 30° 2.2' 2.9' 3.5' 3/4"2.0' 11 1/4°16 47 70 22 1/2° 30° 2.5' 3.6' 4.1' 3/4" 2.5' 2.0' 12" 11 1/4°32 88 132 22 1/2° 30° 3.2' 4.5' 5.1' 3/4"2.0' 3.0'7/8" 16" 70 184 275 4.1' 5.7' 6.5' 7/8"3.0' 4.0'1 1/8" 1 1/4" 20" 1"3.5' 1 3/8"4.5' 128 320 480 6.8' 7.9' 5.0' 1 5/8"5.5' 11 1/4° 22 1/2° 30° 24" 4" 6" 8" 12" 16" 20" 24" 45° 3/4"2.0'68 123 232 5.0' 6.1' 4.1' 3/4"2.5' 30 3.1' 1 1/8"4.0'1 1/4" 478 560 820 8.2' 9.4' 7.8' 1 3/8"4.5' VERTICAL BLOCKING FOR 45° BENDS HOST PIPE HEAVY DUTY PIPE CLAMP (COOPER B-LINE B3132 PIPE CLAMP OR EQUAL) HOT DIPPED GALVANIZED NUT WITH FLAT WASHER, TOP AND BOTTOM (TYP.) ASTM A588, GRADE B, CORTEN ALL THREADED ROD (2) NUTS WITH FLAT WASHER (TYP.) NOTES: 1.THREADED ROD DIAMETER: - PIPE DIAMETER LESS THAN OR EQUAL TO 6": 7/8" - PIPE DIAMETER EQUAL TO 6" OR 8": 1" - PIPE DIAMETER EQUAL TO 10": 1 1/4" - PIPE DIAMETER GREATER THAN 12": 1 1/2" 2.TIGHTEN TOP NUTS TO TENSION BOLTS. 3.TIGHTEN LOWER NUTS TO COMPRESS CLAMP SNUG. C C B A E D 18" 24" MIN. 30" MAX. COVER PRIVATE PLUMBING SHALL CONNECT HERE 1" GALV. PLUG PRIVATE PROPERTY PUBLIC R.O.W. 9-12" NEW DUCTILE IRON WATER MAIN 36" MIN.COVER A EPOXY OR NYLON COATED HIGH TENSILE DI SERVICE SADDLE W/ STAINLESS STEEL STRAP AND EPOXY COATED BOSS, 1" AWWA TAPERED THREAD (CC) TAP, FORD FC101 OR EQUAL, SIZE AS REQUIRED. (FOR ASBESTOS CEMENT PIPE ONLY) 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET (1" FB1000-4-Q) OR AY MCDONALD 4701B FOR COPPER. (DIRECT TAP DUCTILE IRON OR CAST IRON PIPE) 1" TYPE K SOFT COPPER TUBING METER SETTER FOR 1" METER: FORD VBH72-15W-44-44A, MCDONALD BRASS 21-415WCQQ44, OR MUELLER 1-B-2470-2.BOTH INLET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON INLET ANGLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET. ALL FITTINGS SHALL BE WITH QUICK JOINT. METER SETTER SHALL BE INSTALLED CENTERED AND PARALLEL WITH METER BOX. FOR 5/8" X 3/4" METER, PROVIDE METER ADAPTERS TO FIT WITHIN 1" METER SETTER. ARMORCAST PRODUCTS CO. METER BOX NO. A6001946TX18 AND CAST IRON READ LID, 13" X 24" X 2", PART NO. A6001969RCI-H7. B C D E NOTES: 1.SERVICE LINE SHALL BE PERPENDICULAR TO THE WATER MAIN, UNLESS OTHERWISE APPROVED BY THE ENGINEER. 2.APPROVED BACKFLOW PREVENTION MUST BE INSTALLED WITH IRRIGATION SERVICE PER D.O.H. REQUIREMENTS. IRRIGATION SYSTEM SHALL NOT BE PUT INTO SERVICE UNTIL THE BACKFLOW PREVENTION DEVISE IS APPROVED BY ACITY OF RENTON WATER QUALITY TECHNICIAN. 3.AMI WATER METER WITH RADIO & BATTERY UNIT TO BE SUPPLIED BY CITY OF RENTON PUBLIC WORKS DEPARTMENT. 4.IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE, INSTALL FORD C14-33 OR 44 FIPT x COMPRESSION COUPLING. 22 1/2° 12" MIN. RADIUS 1 NOT TO SCALE VERTICAL BLOCKING WITH RESTRAINED JOINTS 2 NOT TO SCALE CONCRETE BLOCKING 3 NOT TO SCALE CONCRETE BLOCKING FOR VERTICAL FITTINGS 4 NOT TO SCALE PIPE CLAMP AND ANCHOR RODS 5 NOT TO SCALE 1-INCH WATER SERVICE MICHAEL J A MES MIT CHELLPROF ESSIONAL ENG IN EE RREGISTEREDSTATE OF WASHIN G TONEXP. 11/21/2019 WATER UTILITY agafour 05/16/2019AS-BUILTAS-BUILT1 BS 06/28 JM D-401713