HomeMy WebLinkAboutD-403003FACILITY ID: MH2087 EX WASTEWATER MANHOLE RIM: 66.31 IE: 61.58-EX 8" (N) IE: 61.58-EX 8" (E) IE: 61.58-EX 8" (S) 12" CONC STORM 24" ABANDONED STORM 40 LF - 24" CMP STORM PHONE SIDE SEWER (NOT FOUND DURING LOCATE) SIDE SEWER (NOT FOUND DURING LOCATE) 8" SEWER WATER METER (TYP.) FIRE HYDRANT GAS (NOT FOUND DURING LOCATE) 3/4" WATER STACKED: 4" AC WATER 2-4" PHONE 12" STORM 8" WATER 4" GAS 2" GAS 10" WATER 8" STORM 42" STORM TAYLOR AVE NW3+34-0+050+00 1+00 2+003+00BP: -0+05.00 EP: 3+34.01 PI: 0+60.09 PI: 1+13.30 PI: 1+57.18 PI: 2+18.60 MH#2 NEW 48" CATCH BASIN TYPE II STA:1+13.30 RIM: 66.82 IE: 63.32-EX 12" (W) IE: 58.50 24" (S) IE: 58.50 24" (N) MH#1 NEW 48" CATCH BASIN TYPE II STA:0+60.09 RIM: 65.36 IE: 63.47-EX 8" (W) IE: 57.97 24" (S) IE: 57.97 24" (N) FACILITY ID: 136670 EX 48" CATCH BASIN TYPE II STA: 0+00.00 RIM: 65.95 IE: 57.37 24" (N) IE: 54.45-EX 42" (W) IE: 54.44-EX 42" (E) MH#3 NEW 48" CATCH BASIN TYPE II STA:2+27.18 RIM: 67.99 IE: 63.99 24" (S) IE: 63.99 24" (N) NEW 43 LF 24" POLYPRO @ 4.83% NEW 71 LF 24" POLYPRO @ 4.82% 1-2" WATER 1-2" ABANDONED WATER SIDE SEWER (NOT FOUND DURING LOCATE) WATER VALVE (TYPICAL) 8" SEWER COM FIBER 3-4" CONDUIT SIDE SEWER (NOT FOUND DURING LOCATE) 12" ABANDONED STORM CITY OF RENTON ROW NEW 60 LF 24" POLYPRO @ 1.00% MH#4 NEW 48" CATCH BASIN TYPE II STA:3+29.01 RIM: 71.92 IE: 67.72-EX 12" (N) IE: 67.72 24" (S) NEW 53 LF 24" POLYPRO @ 1.00% NEW 102 LF 24" POLYPRO @ 3.66% 42" STORM 50 55 60 65 70 75 50 55 60 65 70 75 0+0065.9565.570+5065.3665.451+0065.9367.441+5067.8167.912+0067.9067.992+5068.8970.703+0071.1671.87SIDE SEWER STA: 0+05.08 ELEV: NOT LOCATED 2" WATER STA: 0+45.00 T.O.P. EL: 61.90 2" ABANDONED WATER STA: 0+45.00 T.O.P. EL: 62.10 SIDE SEWER STA: 0+65.78 ELEV: NOT LOCATED 4" GAS STA: 1+05.00 T.O.P. EL: 61.50 8" WATER STA: 1+22.00 T.O.P. EL: 63.00 2-4" PHONE STA: 1+59.18 T.O.P. EL: 64.28 4" AC WATER STA: 1+59.18 T.O.P. EL: 65.37 SIDE SEWER STA: 3+09.84 ELEV: NOT LOCATED SIDE SEWER STA: 2+31.89 ELEV: NOT LOCATED GAS STA: 2+04.18 ELEV: NOT LOCATED 3/4" WATER STA: 1+78.18 T.O.P. EL: 67.67 FACILITY ID: 136670 EX 48" CATCH BASIN TYPE II STA: 0+00.00 RIM: 65.95 IE: 57.37 24" (N) IE: 54.45-EX 42" (W) IE: 54.44-EX 42" (E) NEW 60 LF 24" POLYPRO @ 1.00% MH#1 NEW 48" CATCH BASIN TYPE II STA:0+60.09 RIM: 65.36 IE: 63.47-EX 8" (W) IE: 57.97 24" (S) IE: 57.97 24" (N) NEW 53 LF 24" POLYPRO @ 1.00% MH#2 NEW 48" CATCH BASIN TYPE II STA:1+13.30 RIM: 66.82 IE: 63.32-EX 12" (W) IE: 58.50 24" (S) IE: 58.50 24" (N) NEW 43 LF 24" POLYPRO @ 4.83% NEW 71 LF 24" POLYPRO @ 4.82% MH#3 NEW 48" CATCH BASIN TYPE II STA:2+27.18 RIM: 67.99 IE: 63.99 24" (S) IE: 63.99 24" (N) NEW 102 LF 24" POLYPRO @ 3.66% MH#4 NEW 48" CATCH BASIN TYPE II STA:3+29.01 RIM: 71.92 IE: 67.72-EX 12" (N) IE: 67.72 24" (S) APPROXIMATE GRADE APPROXIMATE GRADE STORM DRAINAGE PLANSWP - 27 - 4030TAYLOR AVE NW STORM IMPROVEMENTS H:\CAD\_PROJECTS\SWP\27-4030_TAYLOR\DWGKEY NOTES CONNECT EXISTING STORM UTILITY TO NEW STRUCTURE. PROVIDE SLIGHT BEND IN 24" POLYPROPYLENE PIPE TO FOLLOW EXISTING STORM ALIGNMENT. 3-4" LUMEN COM FIBER TO BE RELOCATED APPROXIMATELY 3' TO EAST BY LUMEN BETWEEN STATION 0+00 AND STATION 1+15. CONTRACTOR TO EXCAVATE TRENCH 3' WIDER THAN TYPICAL TO EAST TO ALLOW LUMEN TO SHIFT 3-4" FIBER OUT OF STORM ALIGNMENT. CONTRACTOR RESPONSIBLE FOR EXCAVATION AND BACKFILL PER CITY OF RENTON STANDARD PLAN 220.20. RECTANGULAR VANED GRATE PER CITY OF RENTON STANDARD PLAN 204.20 RECTANGULAR BI-DIRECTIONAL VANED GRATE PER CITY OF RENTON STANDARD PLAN 204.30 ROUND FRAME AND COVER PER CITY OF RENTON STANDARD PLAN 204.50 SEE SHEET C200 FOR ADDITIONAL ABANDONMENT DETAILS EXISTING STORM SWALE FROM STATION 1+57.18 TO STATION 2+18.6 TO BE FILLED IN WITH GRAVEL BORROW PER WSDOT STD. SPEC 9-03.14(1), COMPACTED TO 95% OF MAXIMUM DENSITY. GRADES TO MATCH ADJACENT ROADWAY PROFILE AND PROVIDE ADEQUATE DRAINAGE TO NEW PROPOSED STORM SYSTEM. 1 2 3 4 5 6 7 8 Feet 0 40 80 N STORM DRAINAGE NOTES 1.ALL IMPROVEMENTS SHALL FOLLOW CITY OF RENTON CITY STANDARDS. 2.POLYPROPYLENE PIPE SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. MINIMUM OF 1' OF COVER REQUIRED. 3.ALIGNMENT OF NEW SYSTEM FOLLOWS ALIGNMENT OF EXISTING SYSTEM. STATIONS SHOWN ARE FOR DESIGN PURPOSE ONLY. CONTRACTOR TO VERIFY LOCATIONS OF NEW MANHOLES WITH ENGINEER PRIOR TO CONSTRUCTION. 4.CONSTRUCTION OF NEW STORM SYSTEM WILL IMPACT EXISTING SITE FEATURES INCLUDING BUT NOT LIMITED TO SIDEWALKS, CURB AND GUTTER, CONCRETE DRIVEWAY, HMA DRIVEWAY, ETC. ALL EXISTING SITE FEATURES SHALL BE REPLACED TO MATCH EXISTING SITE FEATURES PER CITY OF RENTON STANDARD PLANS UNLESS OTHERWISE NOTED. 4.1.COR STANDRAD PLAN 101 & 103: CEMENT CONCRETE TRAFFIC CURB AND GUTTER 4.2.COR STANDARD PLAN 102: CEMENT CONCRETE SIDEWALK 4.3.CR STANDARD PLAN 104.1: CEMENT CONCRETE DRIVEWAY 1 1 1 2 1 1 PLAN VIEW PROFILE VIEW 1"=20' HORIZONTAL 1"=4' VERTICAL 3 44 65 7 8 3+24.01 71.65 67.62 67.57 101 2+23.18, 3.00L 68.99 IE: 66.01 4" (NW) 64.05 58.60 65.62 58.05 CONCRETE INLET #1 VANED GRATE RIM: FIELD FIT TO LOW SPOT IE: RIM ELEVATION - 1.66' 8" (N) HMA PATCH AROUNDSTRUCTURE CONCRETE INLET #2VANED GRATERIM: MATCH EXISTING IE: RIM ELEVATION - 2.04' 8" (S) IE: RIM ELEVATION - 2.04' 8" (S) HMA PATCH AROUND STRUCTURE APPROXIMATELY 40 LF 8" DUCTILE IRON @ MIN1.0% APPROXIMATELY 6 LF 8" DUCTILE IRON @ MIN1.0% 4 30 65.62 58.05 58.60 2+23.18, 3.00L 68.99 IE: 66.01 4" (NW) 64.05 3+24.01 71.65 67.62 67.57 0.85% 101 4.78% 4.78% 3.49%AS-BUILTAS-BUILT1 BS 07/12 JM D-403003