Loading...
HomeMy WebLinkAboutS-411503Docu5ign Envelope ID:3B1B34D3-7EOA-476C-ADB3-4329FFEOC1QB Docu5ign Envelope 10: 3B1B34D3-7EOA476C-ADB3-4329FFEOC1O8 Dur.c6on Envelope ID 345B681D-914F-4F2D-AR59-7C1921)3B78A3 v J O J 0- LLJ C/ `L O O N N Z J L, SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT, HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT Ti-E REMANING NOTES. IF ADDITIONAL NOTESARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALLBE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1 BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUC DON MEETING SMALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY. THE APPLICANT, AND THE APPLICANTS CONTRACTOR- 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WFFH THE LATEST EDITEON OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL ($RENTON SWDM), RENTON MUNICIPAL CODE (RMCI, AND THE STANDARD SPFCIRCATIONS FOR ROAD, BRIDGE AND MUNICIPAL pDNSTRUCTIpN PREPARED {1Y WSppT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA}. IT 5!-FALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TQ CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL 13E AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAWGE PLAN DOES NOT CONSTIYUtE AS APPROVAL OF ANY OCHER. CON5TRUCTION (E.G. WATER, SEWER GAS- ELECTRICAL- ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. S. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS S. THE LOCATIONS OF ALL EXISTING LMUTES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT FS THE SOLE RESPON5151LFTY OF THE APPLICANT AND THE APPLICANTS CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EWTS. 7- VERTIM DATUM $HALL BE NAVD 80 AND HORIZRNTAL R DATUM SHALL BE MAD B3 (WA STATE PLANE, NORTH}. UNLESS OTHERWISE APPROVED BY THE CY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. B. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95%MMMUM DRY DENSITY PER SECTION 2.03.N14)O - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATTDN AREAS, ALL TRENCH RACKPILL SHALL SE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. A OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CFTY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TC THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHEOLE$, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE ALE STAKED- t 1 ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12. ALL PIPE AND APPURTENANCES SHALL 13E LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHENOTON STANDARD SPECI FIGATIGN FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE T NCH BOTTOM OR THE TOP OF THE FOUNDATION AL I7E RE MATERIAL, A$ WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE. UNYIELDING BABE ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 2N.10. AND 220,20 79. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1.2. OR 5 INS3DE AND OUTSIDE. m. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FFFMO WITH DUCTILE IRON. BOLT-LOCKINCy LID$ PER THE CITY STANDARD PLAN 204 M 204.20. 204.30. 204.40, AND 204 50 STRUCTURES SHALL HAVE: RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. . ROUND, SOLID DDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY. BUT OtFTSDE OF THE CURWGUTTER LINE . ROUND, SOLID LIDS 'DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHTOF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. SUILOINGS AND OTHER STRUCTURE$ SHALL BE PLACED IN ACCORDANCE WFIH TABLE 4.1 EASEMENT WIOTHS AND BUILDING SETBACKS LINES OF THE RENTON 5WDM 15. LIDS OF MANHOLESIGATCH BASINS WITHIN PUBLIC RIGHT-0E-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE+CATCH BASIN RIMS SHALL BE ADJUSTF-O TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN 17. ALL ORNEWAY CULVERTS LOCATED WITHIN CFTY $lIF. T-OP-WAY $HALLBE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3.T SLOPE FROM t HE EDGE OF 1+15 DRIVEWAY TO THE BOTTOM OF THE DITCH, AdlnbL STD. PLAN - 267.00 PUBLIC WORKS SURFACE WATER STANDARD PLAN La�rtin U DEPARTMENT NOTES (1 ❑F 2) Pastucha$/13/2020 DATE Encompass, ENGINEERING & SURVEYING Western Washington Division 165 NE Juniper Street, Suite 20l • IssaQuah, WA 98027 • Phone: (425) 392-0250 Eastern Washington Division 407 Swiftwater Blvd. ■ Cle Elum, WA 98922 ■ Phone: (509) 674-7433 18:4f SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING 13 A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN TFIE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRER TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT, HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTESARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18. ROCKS FOR EROSION PROTECTION OF ROADSIflE DITCHES, WHERE REQUIRED. SHALL BE OF SOUND QUARRY ROCK PLACED TG A MINIMUM DEPTH OF ONE 11) FOOT AND SHALL MEET THE FOLLQWING SPECIFICATIONS; • 4 - B INC H ROCK 141) 4IM PASSING; . 2. 4 INCH ROCK i M - 4n PASSING; AND • LESS THAN 2 INCH ROCK (TO - 20% PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTE3tCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY, FOOTING DRAINS SHALL NOT BE CONNECTED TOONSITE BMPS. 2U THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT,LOCKING LID MARKED "STORM' OR "DRAIN* SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE PRINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 21. ALL STORM SYSTEM EXTENSIONS SHALL 8E STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDEL TO THE CITY PRIOR TO CONSTRUCTION. 22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED Qv MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTAL I. PROJECT CURBS- GUTTERS ANDIOR PAVEMENT 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 74D4.3I1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CFTY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED 24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED. GRADED. LANDSCAPED, ETC.) DF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE ESA"NG DUFF LAYER AND fiATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 2G4.0D 25 ISSUANCE OF THE SULLDIA* OR CONSTRUCTION PERMITS BY THE C17Y DOES NOT RELIEVE THE APPWCANT OF THE CONTINUING LEGAL OBLIGATION ANDIOR L11131LITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT AGGEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AMC, MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT. FLAGGERS, AND ANY OTHER AC-IDNS NEEDED TO PROTECTTHE LIFE, HEAL-TH, AND SAFETY OF THE PUUUIC, ANI) TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PRGVIQEO. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAYTHAT MAY INTERRUPT NORMAL TRAFFIC FLAW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CFTY ALL SECTIONS OF THE W,%WT STANDARD SPECIFICATIONS I -ID TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CnY'S AOUIFER PROTECTION AREA {APR} SHALL COMPLY WITH SPECIAL REQUIREMENT 46 OF THE RENTON SWDM AND AOUIFER PROTECTION REGULATIONS (RMC 4-3-MO). 29. PLACEMENT OF SURFACE APPURTENANCES {CATCH BASIMMANHOLE LIDS, CLEANOLFTS, INLETS, ETC,I IN THE STREET TRAVEL LANE WHEEL PATH. INTERSECTIONS OF STREET TRAVEL LANES. BIKE LANES, SIDEWALKS, AND GROSSWALKS SHALL BE AVOIDED WHENEVER POSS18LE ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA. REQUIREMENTS 2S. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWIM. S1. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS SEEN WETTED CONTINUCUSLY FOR AT LEAST 10 MINUTES- COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAYBE CHECKED USING A SIMPLE 9UCK�T TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALLAT ONCE, IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ARSORPTI¢N. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,DBO SQUARE FEET # PERMEABLE PAVEMENT- IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS IE G., PARKING AREAS). TESTING OBSERVATION MAYBE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO T11E BUCKETTEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TD SCALE INTS) STD. PLAN - 267.10 PUBLIC WORKS SURFACE WATER STANDARD PLAN [WOULMIN-7 DEPARTMENT NOTES (2 OF 2) arfin Pastuchk13/2020 MtEgglF iF3i LLU ^,w. 04"D DATE I 8:48 WASTEWATER UTAITV STANDARD NDTES 1 ALL WORK AND MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE VV800TIAFVVA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON STANDARD PLANS & SPECIFICATIONS A SET OF APPROVI=D PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION 2 CA-RJM FOR VERTICAL CONTROL SHALL 13E NORTH AMERICAN VERTICAL DATl1M 1988 HORIZONTAL CONTROL $HIAL-L BE NORTH AMERICAN DATUM igOT1991 UNLESS OTHERWISE APPROVED BY THE CITY BENCHMARKS AND MONUMENTS SHAM_ BE REFERENCED ON THE APPROVED PLANS 3 A PRE -CONSTRUCTION CONFERENCE AND A 24-HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS. INi�UDING STREET USE PEIRMITS, PRIOR TO STARTING CONSTRUCTION INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF TH£ CITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUSIAC WORKS INSPECTOR 24 HOURS IN ADVANCE OF SACKFILLING ALL CONSTRUCTION 4 THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY 5 CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND CTHEA-S ON THE CONSTRUCTION SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. B. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR OISTURBANCE THE CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF RCW 19 122 A DIG TICKET SHALL BE OBTAINED A MINIMUM OF TWO BUSINESS DAYS PRIOR TO STARTING ANY EXCAVATION THE CONTRACTOR SHALL HAVE ACOPY OF THE DIG TICKET ON SITE AT ALL TIMES 7- BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 12-INCHES, MAXIMUM DEPTH 1&INCHES. THOROUGHLY COMPACTING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO COMPLETE THE FILL OVER THE PIPE SHALL BE ECUIVALENT TO BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19). 8 SA4 fTARY SEWER PIPE SHALL BE POLYwNYL CHLORIDE (PVC) RUBBER-GASKETED ASTM D 3034. SOR 35, CWCJC905 OR DUCTILE IRON CLASS So, UNLESS OTHERWISE APPROVED BY THE CITY 9 SANITARY SEWER PIPES SHALL NOT BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC) UNLESS APPROVED 8Y THE CITY IF A SANITARY SEWER IS TO BE LOCATED UNDER ANY STRUCTURE (WALL, BUILDING FOUNDATION, ETC.), IT SHALL BE DESIGNED HY A PROFESSIONAL ENGINEER LICENSED IN T-HE STATE OF W HIN T AS G ON IN ACCORDANCE WITH stANDARo DETAIL 412 10. OPEN -CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAYS SHALL BE BACKFILLED WITH CRUSHED SURFACING AGGREGATE I WSDOT SPECIFICATION 9-039(3) AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY t1 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANOA.RDS AND SPECIFICATION OF THE CITY AND THE LATEST EDITION OF THE WSDOTIAPWA STANDARDS AND SPECIFICATION AS APPROVED AND MODIFIED BY THE CITY IN THE RENTON STANOARD PLANS 8 SPECIFICATIONS THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL TO A UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE PIPE BEI)MNG SHALL BE IN ACCORDANCE WITH STANDARD PLAN 405 12 ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE CITY FOR THE PREVENTION OF OWSME EROSION BOTH DURING CONSTRUCTION ANDAFTERTHE COMPLETION OF CONSTRUCTION IN ACCORDANCE WITH THE CURRENT SURFACE WATER DESIGN MANUAL 13 THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH A RECORD DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR • PUBLIC W OAKS WASTEWATER UTILITY STP.- PLAN - 413 Arr arnrta DEPARTMENT Martin Pastucha�olz6l2 STANDARD NOTES .,,." .,.......,�.n. DATE 6 REVISED PER ASBUILT SURVEY CP 04/17/2024 SURVEYED: SDM z 5 REVISIONS PER FIELD CONDITIONS CP 0911512023 DESIGNED: 4 REVISIONS PER FIELD CONDITIONS CP 0912812022 NEM 3837�5 �'v 3 REVISIONS PER CITY COMMENTS DATED 6/23/2021 CP 07/01/2021 DRAWN:TLK p S`SjONAL � 2 REVISIONS PER CITY COMMENTS DATED 410712021 CP 0410812021 CHECKED: 0510112024 N0. REVISION BY DATE APPR EDM APPROVED: CA SCALE: N/A ONE INCH AT FULL --.- IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M 10 1 1 Know what's below. Call before you dig. CITY OF RENTON Planning/Building/Public Works Dept. S411503 R-411510 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SKYHORSE SHORT PLAT PR 17- 000438 ASBUILT CONSTRUCTION NOTES DATE: 0611712024 FIELDBOOK: PAGE: 22587 SHEET: OF: 12 20 7 ON u• 0 Z