HomeMy WebLinkAboutCA_Structural Calcs_Earlington_Shoring_171013_v1 DIBBLE ENGINEERS INC | 1029 Market Street, Kirkland WA 98033 | 425.828.4200 | dibbleengineers.com STRUCTURAL CALCULATIONS EARLINGTON SHORING 8074 132nd Street Renton, WA Prepared for Blue Fern Project # 17-052 October 13, 2017 10/13/2017 DIBBLE ENGINEERS INC | 1029 Market Street, Kirkland WA 98033 | 425.828.4200 | dibbleengineers.com STRUCTURAL CALCULATIONS TABLE OF CONTENTS Earlington Shoring & DEI Job #17-052  Design Criteria and Loads 1-XX  Shoring XX-XX o Pile o Timber Lagging DIBBLE ENGINEERS INC | 1029 Market Street, Kirkland WA 98033 | 425.828.4200 | dibbleengineers.com DESIGN CRITERIA Earlington Shoring & DEI Job #17-052 35 (H+D) PSF FOR UNRESTRAINED CONDITIONS AND LEVEL BACKSLOPE 50 (H+D) PSF FOR RESTRAINED AT REST ACTIVE PRESSURE ACTS OVER SOLDIER PILE SPACING ABOVE EXCAVATION LEVEL AND ONE PILE DIAMETER BELOW THE EXCAVATION LEVEL HBASE OF EXCAVATION GROUND SURFACE 300 (D) PSF PASSIVE PRESSURE ACTS OVER TWICE PILE DIAMETER PASSIVE PRESSURE BASED ON DEPTH BELOW BASE OF EXCAVATION 250 PSF TRAFFIC SURCHARGE ROAD / SIDEWALK SURCHARGE SEISMIC SURCHARGE 5H PSF ACTIVE 10H PSF AT REST D = VARIES2’ NOTES: 1. SOLDIER PILE EMBEDMENT DEPTH “D” SHOULD CONSIDER NECESSARY VERTICAL CAPACITY, KICKOUT, AND OVERTURNING RESISTANCE. 2. PASSIVE PRESSURE INCLUDES A FACTOR OF SAFETY OF 1.5. 3. DIAGRAM DOES NOT INCLUDE HYDROSTATIC PRESSURES AND ASSUMES WALLS ARE SUITABLY DRAINED TO PREVENT BUILDUP OF HYDROSTATIC PRESSURE. 4. DIAGRAM IS ILLUSTRATIVE AND NOT REFERENCED TO A PARTICULAR LOCATION. 5. LAGGING MAY BE DESIGNED USING 50 PERCENT OF THE ACTIVE EARTH PRESSURE. 6. SLOPE ABOVE SHORING WALL SHALL BE NO STEEPER THAN 1.5H:1V. 7. SURCHARGE SHOULD BE ADDED FOR ANY ROADS, FOUNDATIONS, MATERIAL STOCKPILES, ETC., NOT SHOWN ABOVE, IN ACCORDANCE WITH FIGURE 4. MINTER PROPERTY RENTON, WASHINGTON 160641 Minter \ 160641 F3 Soldier 4-17.cdrPERMANENT SOLDIER PILE WALL DESIGN CRITERIA PROJ NO.DATE:FIGURE: 160641E001 4/17 3 a s s o c i a t e d e a r t h s c i e n c e s i n c o r p o r a t e dDRAFT MINTER PROPERTY RENTON, WASHINGTON 160641 Minter \ 160641 F4 Pressure.cdrSURCHARGE PRESSURE ON ADJACENT WALLS PROJ NO.DATE:FIGURE: 160641E001 4/17 4 a s s o c i a t e d e a r t h s c i e n c e s i n c o r p o r a t e d LEGEND: EXCAVATION DEPTH BELOW FOOTING IN FEET LATERAL SOIL PRESSURE IN PSF UNIT LOADING PRESSURE IN PSF RADIANSb sh D q a b q b/2 sh DGROUND SURFACE BASE OF EXCAVATION ISOLATED FOOTING abbsh= 0.64q ( - SIN COS2 ) sh DGROUND SURFACE BASE OF EXCAVATION X = mDq LINE LOAD PRESSURE z = nDCONTINUOUS FOOTING PARALLEL TO EXCAVATION (FOR m>0.4) sh =1.28q D 2m n 2 2 2(m + n ) sh =q D 0.2 n 2 2(0.16 + n ) (FOR m<0.4) UNIFORM LOAD DISTRIBUTION sh q = VERTICAL PRESSURE IN PSF = 0.4q BASE OF EXCAVATION sh UNIFORM LOAD q DRAFT DIBBLE ENGINEERS INC | 1029 Market Street, Kirkland WA 98033 | 425.828.4200 | dibbleengineers.com SHORING Earlington Shoring & DEI Job #17-052