HomeMy WebLinkAboutP_Site_Plan_Earlington_180104_v1SITE PLAN1" = 30'Key LegendEntry DoorParking StallPrivate usable openspace. This providesno less that 225 squarefeet of usable open spacewith no dimension lessthan 8'Designated Waste & recycling pads 2'X6' SPACE FOR EACH UNITBollard = P5245-31Wall Sconce = P5642-31Spot Light =Fire HydrantGas MeterWater MeterHeat PumpElectric MeterSite SignFire LaneNOTE: LANES SHALL BE IDENTIFIED BY AFOUR INCH (4") WIDE LINE AND CURB PAINTEDBRIGHT RED. THE BLOCK LETTERS SHALL STATE,“FIRE LANE - NO PARKING”, BE EIGHTEEN INCHES(18") HIGH, PAINTED WHITE, LOCATED NOT LESSTHAN ONE FOOT (1') FROM THE CURB FACE, ATFIFTY FOOT (50') INTERVALS.S 132nd StRenton Ave. SLot CoverageTotal building footprints52,110.3 S.F.Lot Coverage 28.7%Landscaping AreaUnit CountUnit A-2029Unit E-163Unit E-20 28Number of Units 60Building Plate Height allowed =24'-0"Building Plate Height Provided =22'-758"Building Height Provided= 29'-1012"Building Height allowed = 30'-0"(including 6'-0" roof slopeallowance)Minimum Front Yard Setback=15'Side Yard Setback (unattached) = 5'Side Yard Setback Attached=0'Rear Yard Setback =10'Front yard setback provided = 15' +Side Yard Setback (unattached) Provided = 5' +Rear Yard Setback Provided (per PPUD) = 10' +Parking consists of private enclosed stalls at each individual unitand 4 parallel guest stalls.Private garage stalls are 8.5x16Guest parallel stalls are 9x23Parking: 3 Bedrooms Units 1.6 = 83.2 Spaces Required (104Provided)Parking: 2 Bedrooms Units 1.4 = 14 Spaces Required (20 Provided)Building Coverage InformationBuildingCountLot CoverageImperviousType 113,692.4SFEach4,166.0SFEachType 232,771.8SFEach3,120.4SFEachType 321,850.2SFEach2,119.8SFEachType 435,665.7SFEach6,405.4SFEachType 523,336.2SFEach3,855.8SFEachType 611,667.8SFEach2,012.5SFEachType 725,532.4SFEach6,049.5SFEachTotal Building Coverage52,110.3SFTotal Building Impervious58,806.1SFSITE INFORMATIONSite Address:8074 S 132nd Street Renton, WashingtonLegal Description:EARLINGTON ACRE TRS LESS CO RD LESS POR OF LOT 7 LYING WLYOF LN DAF - BEG AT SW COR OF SD LOT 7 TH S 87-30-06 E 8.15 FTALG S LN OF SD LOT TO TPOB OF SD LN TH N 00-22-46 E TO W LN OFSD LOT 7 & END OF DESC LN 07-2-33638-9 KNT REC 20071212000820Parcel Numbers:2144800285, 2144800295, 2144800500, 2144800488 & 2144800487Land Use Zone:ResidentialZoning:R-14Site Area: 181,297 SF 4.16 acresBuildingImpervious Area:58,806.1 SFUnit Count:Unit E16 3Unit E20 28Unit A2029Total 60 UnitsParking:Unit E16: 2 Bed @ 1.4 per unit = 4.2 stalls requiredUnit E20: 3 Bed @ 1.6 per unit = 46.4 stalls requiredUnit A20: 4 Bed @ 1.6 per unit = 46.4 stalls requiredRequired Stalls = 97 stalls required Proposed Stalls:Unit E16: 2 stalls per unit= 6 stallsUnit E20: 2 stalls per unit= 56 stallsUnit A20: 2 stalls per unit= 58 stallsAttached Garage Stalls= 120 stalls providedOn Street Parking= 4 Potential Parallel stallsTotal: = 124 Stalls ProvidedUnit InformationUnitTypebed/bathUnit Gross SFUnit Net SFUnit CountUnit E16Tuck Under2/2.51,3581,3153Unit E20Tuck Under3/2.51,7231,65516Unit E20 EndTuck Under3/2.51,7811,68812Unit A20Daylight Basement4/3.51,8671,79613Unit A20 EndDaylight Basement4/3.51,9081,81616E20A20A20A20E20E20E20E20E20E20E20E20A20E20E20E20E20A20A20A20E16A20A20A20A20A20A20A20A20A20A20A20A20A20A20A20A20A20A20A20BLDG 2TYPE 2BLDG 9TYPE 4BLDG 3TYPE IBLDG 1TYPE 2BLDG 7TYPE 7BLDG 10TYPE 5BLDG 11BLDG 4TYPE 3BLDG 8TYPE 7BLDG 5TYPE 4BLDG 6TYPE 4BLDG 14TYPE 6BLDG 12TYPE 2E20BLDG 13TYPE 5A20A20A20E20E20E20E16E20E20E20E20E16E20E20E20E20E20E20E20MAIL KIOSK18-P COMMERCIAL 4C PEDESTAL MAILBOXAverage Grade PlaneBuilding 1 Grade Plane CalculationsNorth246.9+246.90/2=246.9South236.2+236.20/2=236.2East246.9+236.20/2=241.55West246.9+236.20/2=241.55966.2/#=241.55Building 2 Grade Plane CalculationsNorth245.8+246.20/2=246South235.5+235.10/2=235.3East245.8+235.10/2=240.45West235.5+246.20/2=240.85962.6/#=240.65Building 3 Grade Plane CalculationsNorth245.6+246.50/2=246.05South235.8+235.30/2=235.55East235.8+246.50/2=241.15West245.6+235.30/2=240.45963.2/#=240.8Building 4 Grade Plane CalculationsNorth247.3+247.30/2=247.3South236.6+236.60/2=236.6East236.6+247.30/2=241.95West247.3+236.60/2=241.95967.8/#=241.95Building 5 Grade Plane CalculationsNorth255.5+253.90/2=254.7South245.61+247.43/2=246.52East247.43+255.50/2=251.465West253.9+245.61/2=249.7551002.44/#=250.61Building 6 Grade Plane CalculationsNorth254.1+255.00/2=254.55South246.94+245.90/2=246.42East245.9+254.10/2=250West255+246.94/2=250.971001.94/#=250.485Building 7 Grade Plane CalculationsNorth270.5+268.30/2=269.4South257.6+259.80/2=258.7East259.8+270.50/2=265.15West257.6+268.30/2=262.951056.2/#=264.05Building 8 Grade Plane CalculationsNorth267.5+266.80/2=267.15South256.1+256.10/2=256.1East256.1+266.80/2=261.45West267.5+256.80/2=262.151046.85/#=261.713Building 9 Grade Plane CalculationsNorth274.6+275.50/2=275.05South267.53+266.37/2=266.95East266.37+274.60/2=270.485West275.5+267.53/2=271.5151084/#=271Building 10 Grade Plane CalculationsNorth276.5+275.50/2=276South266.46+268.51/2=267.485East268.51+276.50/2=272.505West275.5+266.46/2=270.981086.97/#=271.743Building 11 Grade Plane CalculationsNorth270.3+270.30/2=270.3South280.1+280.10/2=280.1East280.1+270.30/2=275.2West270.3+280.10/2=275.21100.8/#=275.2Building 12 Grade Plane CalculationsNorth273+273.00/2=273South282.3+282.30/2=282.3East273+282.30/2=277.65West282.3+273.00/2=277.651110.6/#=277.65Building 13 Grade Plane CalculationsNorth290+291.00/2=290.5South283.11+280.80/2=281.955East280.8+290.00/2=285.4West291+283.11/2=287.0551144.91/#=286.228Building 14 Grade Plane CalculationsNorth288.3+288.30/2=288.3South280.35+279.04/2=279.695East279.04+288.30/2=283.67West288.3+280.35/2=284.3251135.99/#=283.998A2SITE PLAN
1" = 30'-0"Sheet Order: A B U F R E S D BEH:\1756\SITE PLAN.DWG
1-4-18 Copyright 2017 Milbrandt Architects, INC., P.S. All rights reserved.
EARLINGTON TOWNHOMES
A 62 Unit Townhome Development
City of Renton, Washington
Polygon Northwest Company17-56Date Plotted:Date:Drawn By:Scale:
C
DateNo.Sheet No.:Job No.:Web: www.milbrandtarch.comP: 425.454.7130 F: 425.658.1208Kirkland, Washington 9803325 Central Way, Suite 210M i l b r a n d tA r c h i t e c t sB18001196 (GREENHOUSE) / B18001509 SF HOUSE / PR17-000187 V.1RECEIVED03/27/2018kjpetersonBUILDING DIVISIONAPPROVEDBUILDING DIVISIONTHIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.DATE: 04/03/2018