HomeMy WebLinkAboutP_DrainagePlan_Meadow_View_Lot04_190208_v2YD1
4
LAND USE SUMMARY
CP H
ONSULTANT S
11431 Willows Rd. NE, Suite 120
Redmond, WA 98052
Phone: (425) 285-2390 | FAX: (425) 285-2389
www.cphconsultants.com
Site Planning • Civil Engineering
Land Use Consulting • Project Management
Copyright © 2018 CPH Consultants, LLC. All Rights Reserved.IN FEETPLAN
0
N
CONSTRUCTION NOTES
MEADOWVUE - LOT 4
STORM DRAINAGE PLAN
20
LEGAL DESCRIPTION
LEGEND
PR17000137
B19002102
V2
REVISION
Received: 05/31/2019 / aalexander
BUILDING DIVISION
APPROVEDBUILDING DIVISION
THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALLTIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BEOCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTONBUILDING DIVISION AND RECEIPT OF CERTIFICATE OFOCCUPANCY.
APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TOVIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,OR OTHER REGULATIONS ENFORCED BY THIS CITY.
DATE: 06/10/2019
MEADOWVUE - LOT 4
DETAILS AND NOTES
CP H
ONSULTANTS
11431 Willows Rd. NE, Suite 120Redmond, WA 98052
Phone: (425) 285-2390 | FAX: (425) 285-2389
www.cphconsultants.com
Site Planning • Civil Engineering
Land Use Consulting • Project Management
Copyright © 2018 CPH Consultants, LLC. All Rights Reserved.
LOT 4 STORM DRAINAGE SUMMARY
·
·
·
·
·
·
·
·
SPLASHBLOCK FOR BASIC DISPERSION
PLAN VIEW OF PARCEL
TO STORM DRAINSYSTEMRIGHT-
OF-WAYGENERAL
NOTES:1.INFILTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM SINGLE-FAMILY OR DUPLEX HOMES OR TO
CONTROL BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND
INJECTION CONTROL PROGRAM (UIC) FOR OTHER TYPES OF RUNOFF
MANAGEMENT.2.IMPERVIOUS AREAS LARGER THAN 10,000 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 35,000 SF MAY
REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL
ENGINEER.3.THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN
25%.4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT
REQUIREMENTS.24"
MIN.18"
MIN.MIN. 1' ABOVE SEASONAL
HIGH GROUNDWATER
TABLE 6"
MIN.1 1/2" - 3/4"
WASHED DRAIN
ROCK NON-WOVEN GEOTEXTILE FOR
SEPARATION ON TOP AND SIDES OF TRENCH PER
WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE
3 COMPACTED TOPSOIL OR OTHER CLEAN
FILL 6" MIN.
PVC PERFORATED
PIPE PER ASTM
D1785 10' MIN. LEVEL TRENCH
WITH PERFORATED PIPE, SEE NOTE
1 DOWNSPOUT WITH
CLEANOUT FILTER, SEE
DETAIL ASECTION
A
NOTES:1.TRENCH LENGTH TO BE 10 FEET IN LENGTH FOR EVERY 5,000 SF OF CONTRIBUTING IMPERVIOUS SURFACE, OR 35,000
SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTION
THEREOF.
5'
MIN.
5'
MIN.TO STORM DRAIN
SYSTEM
5'
MIN.
5'
MIN.
A DOWNSPOUT WITH CLEANOUT FILTER, SEE
DETAIL 10' MIN. LEVEL TRENCH
WITH PERFORATED PIPE, SEE NOTE
1 CONFIGURATION ON FLAT
GROUND CONFIGURATION ON SLOPING
GROUND UNDISTURBED NATIVE
SOIL CLEANOUT PER STD. PLAN 226.
00 CLEANOUT
PER STD. PLAN 226.
00 FILTER
SCREEN 2'-5'
TO
GROUND
SOLIDS/
LEAVES TYPICAL
DOWNSPOUT FILTER
DETAIL FOOTING DRAIN
BYPASS CLEANOUT
PER STD. PLAN 226.
00 PERFORATED STUB-
OUT
CONNECTION PUBLIC
WORKS
DEPARTMENT
APPROVED:DATEGregg
Zimmerman Public Works
Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (
NTS)STD. PLAN - 263.
40 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-