HomeMy WebLinkAboutD_Administrative_Decision_Sierra_Homes_Short_Plat_230807_FINDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Project Location Map
D_Sierra Homes Short Plat Decision_20230726_FIN
A. ADMINISTRATIVE REPORT & DECISION
Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED
Report Date: August 7, 2023
Project File Number: PR22-000352
Project Name: Sierra Homes Short Plat
Land Use File Number: LUA22-000427, SHPL-A, MOD
Project Manager: Alex Morganroth, Senior Planner
Owner: Awesome Yah Church, 702 Nile Ave NE, Renton, WA 98059
Applicant/Contact: Ian Dahl, Encompass Engineering & Surveying /165 NE Juniper St, Ste 201, Issaquah
WA 98027/ idahl@encompasses.net
Project Location: 702 Nile Ave NE (APN 1123059002)
Project Summary: The applicant is requesting preliminary short plat approval and a street modification
to subdivide one existing parcel into three (3) new lots and one (1) stormwater tract.
The subject property is located at 702 Nile Ave NE (APN 1123059002) near the
intersection of Nile Ave NE and NE 7th Pl. The parcel totals approximately 31,996 sq.
ft. (0.74 acres) in size. Two (2) existing structures are located on the parcel: a
residence and an associated accessory structure. The applicant is proposing to
remove both buildings as part of the project. The site has a Comprehensive Plan Land
Use of Designation of Residential Low Density (RLD) and a zoning designation of
Residential-4 (R-4) dwelling units per net acre (du/ac). The size of the proposed lots
range from 9,214 to 9,733 sq. ft. Access to the three (3) lots is proposed via individual
driveways off of NE 7th Pl. According to COR Maps, no critical area s are present on
the project site. An off-site Category III wetlands is mapped to the southeast of the
site. The lot proposed for subdivision was created as part of the Weston Heights
North Short Plat approved in 2017 (LUA16-000140). The applicant identified five (5)
trees on the project site, of which they're proposing to remove all five (5) trees. The
applicant submitted a geotechnical report, drainage report, arborist report, and
wetlands assessment with the application.
Site Area: 0.74 acres
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 2 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
B. EXHIBITS:
Exhibit 1: Administrative Decision
Exhibit 2: Preliminary Plat Plan
Exhibit 3: Neighborhood Detail Map
Exhibit 4: Civil Plan Set
Exhibit 5: Landscape Plan, Tree Retention Plan, and Worksheet
Exhibit 6: Arborist Report, prepared by Layton Tree Consulting, LLC, dated April 14, 2022, revised
October 26, 2022
Exhibit 7: Technical Information Report (TIR), prepared by Jacobson Consulting Engineer, dated
April 24, 2023
Exhibit 8: Geotechnical Report, prepared by Cobalt Geosciences, dated October 4, 2021
Exhibit 9: Wetland Reconnaissance, prepared by Altmann Oliver Associates, LLC, dated
December 10, 2021
Exhibit 10: Modification Request
Exhibit 11: Advisory Notes
Exhibit 12: Public Comment, Wilson
C. GENERAL INFORMATION:
1. Owner(s) of Record: Awesome Yah Church, 702 Nile Ave NE, Renton, WA
98059
2. Zoning Classification: Residential-4 (R-4)
3. Comprehensive Plan Land Use Designation: Residential Low Density (LD)
4. Existing Site Use: Existing single-family residence and associated
detached accessory structure to be demolished
5. Critical Areas: None
6. Neighborhood Characteristics:
a. North: Single family; Residential-4 du/ac (R-4) zone
b. East: Single family; Residential-4 du/ac (R-4) zone
c. South: Single family; Residential-4 du/ac (R-4) zone
d. West: Single family; Residential-4 du/ac (R-4) zone
7. Site Area: 0.74 acres
D. HISTORICAL/BACKGROUND:
Action Land Use File No. Ordinance No. Date
Shamrock Annexation A-09-001 5459 07/05/2009
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 3 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
Comprehensive Plan N/A 5758 06/22/2015
Zoning N/A 5758 06/22/2015
Weston Heights North
Short Plat
LUA16-000140 N/A 04/07/2016
E. PUBLIC SERVICES:
1. Existing Utilities
a. Water: Water service will be provided by King County Water District 90.
b. Sewer: Sewer service will be provided by the City of Renton. There is an existing 8-inch gravity
wastewater main located in NE 7th Pl north of the proposed site. There is an existing 8-inch gravity
wastewater main located in Nile Ave NE starting near the southwest corner of the property. There is
an existing PVC sewer stub serving the existing home on the property.
c. Surface/Storm Water: The site is slightly sloped from the northeast to the southwest. There is an
existing 15-inch public stormwater main on the south side of NE 7th Pl. There is an existing 15-inch
public stormwater main on the east side of Nile Ave NE. An existing gravel trench running along the
west edge of the parcel connects to a 6-inch PVC pipe that runs north and connects into a public
catch basin located at the intersection of Nile Ave NE and NE 7th Pl.
2. Streets: The proposed development fronts NE 7th Pl along the north property line. NE 7th Pl is classified as
a Residential Access street with an existing ROW of approximately 53-67 feet, however the centerline is
offset and approximately 26.5 – 36.5 feet of ROW fronts the property. The proposed development fronts
Nile Ave NE along the west property line. Nile Ave NE is classified as a collector arterial street with an
existing ROW of approximately 66.5 feet, however the centerline is offset and approximately 36.5 feet of
ROW fronts the property.
3. Fire Protection: Renton Regional Fire Authority (RRFA)
F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE:
1. Chapter 2 Land Use Districts
a. Section 4-2-020: Purpose and Intent of Zoning Districts
b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations
c. Section 4-2-110: Residential Development Standards
d. Section 4-2-115: Residential Design and Open Space Standards
2. Chapter 4 City-Wide Property Development Standards
3. Chapter 6 Streets and Utility Standards
a. Section 4-6-060: Street Standards
4. Chapter 7 Subdivision Regulations
a. Section 4-7-070: Detailed Procedures for Short Subdivision
5. Chapter 9 Permits Specific
a. Section 4-9-250: Variances, Waivers, Modifications, and Alternates
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 4 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
6. Chapter 11 Definitions
G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN:
1. Land Use Element
2. Utilities Element
H. FINDINGS OF FACT (FOF):
1. The Planning Division of the City of Renton accepted the above master application for review on January
4, 2023 and determined the application complete on the same day. The project was placed on hold
January 24, 2023 and taken off hold on March 24, 2023. The project was placed on hold again on May 5,
2023 and taken off hold on July 1, 2023. The project complies with the 120-day review period.
2. The project site is located 702 Nile Ave NE (APN 1123059002).
3. The project site is Lot 1 of the Weston Heights North Subdivision. Per RMC 4-7-070.C.2, no application for
a short subdivision shall be approved if the land being divided is held in common ownership with a
contiguous parcel that has been subdivided in a short subdivision within the preceding five (5) years. Such
applications shall be processed as preliminary plat, rather than a short plat. The Weston Heights North
Subdivision was recorded in 2017 and therefore the subject project exceeds the five (5)-year limit and
does not need to utilize the preliminary plat process.
4. The project site is currently developed with a single-family home and detached accessory building.
5. Access to the site would be provided via three (3) new driveways, one for each lot, off of NE 7th Pl.
6. The property is located within the Residential Low Density (LD) Comprehensive Plan land use designation.
7. The site is located within the Residential-4 (R-4) zoning classification.
8. There are five (5) trees located on-site, of which the applicant is proposing to remove all five (5) trees.
9. No critical areas are mapped on the project site. The applicant submitted a Wetlands Reconnaissance
survey prepared by Altmann Oliver Associates, LLC, dated December 10, 2021 (Exhibit 9). The report
identifies an off-site Category III wetlands to the southeast of the site. The Category III depressional
hydrogeomorphic wetlands is located in a tract created as part of the Weston Heights North Subdivision
(LUA16-000140). Neither the wetlands or required buffer extend onto to the project site and no impacts
to the wetlands are proposed.
10. Approximately 10 cubic yards of material would be cut on-site and approximately 10 cubic yards of fill is
proposed to be brought into the site.
11. The applicant is proposing to begin construction in fall of 2023.
12. Staff received one public comment letter (Exhibit 12) which included concerns related to ROW landscaping
impacts.
13. Representatives from various city departments have reviewed the application materials to identify and
address issues raised by the proposed development. These comments are contained in the official file,
and the essence of the comments has been incorporated into the appropriate sections of this report and
the Departmental Recommendation at the end of this report.
14. Comprehensive Plan Compliance: The site is designated Residential Low Density (LD) on the City’s
Comprehensive Plan Map. The purpose of the MD designation is to allow a variety of single-family and
multi-family development types, with continuity created through the application of design guidelines, the
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 5 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
organization of roadways, sidewalks, public spaces, and the placement of community gathering places
and civic amenities. The proposal is compliant with the following Comprehensive Plan Goals and Policies
if all conditions of approval are met:
Compliance Comprehensive Plan Analysis
✓ Policy L-3: Encourage infill development of single-family units as a means to meet
growth targets and provide new housing.
✓
Goal L-I: Utilize multiple strategies to accommodate residential growth, including:
• Development of new single-family neighborhoods on large tracts of land outside
the City Center,
• Development of new multi-family and mixed-use in the City Center and in the
Residential High Density and Commercial Mixed Use designations, and
• Infill development on vacant and underutilized land in established neighborhoods
and multi-family areas.
✓
Policy L-24: Manage urban forests to maximize ecosystem services such as stormwater
management, air quality, aquifer recharge, other ecosystem services, and wildlife
habitat.
✓ Goal L-BB: Maintain a high quality of life as Renton grows by ensuring that new
development is designed to be functional and attractive.
✓ Goal L-FF: Strengthen the visual identity of Renton and its Community Planning Areas
and neighborhoods through quality design and development.
✓ Policy L-48: Address privacy and quality of life for existing residents by considering
scale and context in infill project design.
15. Zoning Development Standard Compliance: The site is classified Residential-4 (R-4) on the City’s Zoning
Map. The R-4 designation serves as a transition between rural designation zones and higher density
residential zones. It is intended as an intermediate lower density residential zone. The proposal is
compliant with the following development standards, as outlined in RMC 4-2-110.A, if all conditions of
approval are met:
Compliance R-4 Zone Develop Standards and Analysis
✓
Density: There is no minimum density required in the R-4 zone. The maximum density
permitted is 4.0 dwelling units per net acre. Net density is calculated after the
deduction of sensitive areas, areas intended for public right-of-way, and private access
easements.
Staff Comment: The applicant submitted a Density Worksheet with the application.
Based on the site’s net area of 31,996 sq. ft. (0.74 acres), the proposal would result in
a net density of 4.08 du/ac (3 dwelling units/0.74 acres). Per RMC 4-11-040 Definitions
D ‘Density’, all fractions which result from net density calculations shall be truncated
at two (2) numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations for
minimum or maximum density which result in a fraction that is one -half (0.50) or
greater shall be rounded up to the nearest whole number. Thos e density calculations
resulting in a fraction that is less than one-half (0.50) shall be rounded down to the
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 6 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
nearest whole number. Therefore, the proposal is compliant with the density
requirements for the R-4 zone.
✓
Lot Dimensions: The minimum lot size permitted in the R-4 zone is 9,000 sq. ft. A
minimum lot width of 70 feet is required (80 feet for corner lots) and a minimum lot
depth of 100 feet is required.
The following table identifies the proposed approximate dimensions for Lots 1-3:
Proposed Lot Lot Size (sq. ft.) Lot Width (ft.) Lot Depth (ft.)
Lot 1 9,214 80.78 108.6*
Lot 2 9,417 70.05 145
Lot 3 9,733 87.41 104.10
Tract 3,634 N/A N/A
Staff Comment: Proposed Lots 1, 2, and 3 are oriented with front yards facing north
towards NE 7th Pl and have lot areas and dimensions that exceed the minimum lot size,
width, and depth requirements of the R-4 zone.
*Lot depth for proposed Lot 3, an irregularly shaped lot, was calculated by measuring
the distance between the midpoint of the front property line (north) and the midpoint
of the two rear property lines (south, including both arc and straight line).
Compliant if
Condition of
Approval is
met
Setbacks: The required setbacks in the R-4 zone are as follows: front yard is 30 feet,
side yard is combined 20 feet with not less than 7.5 feet on either side, secondary front
yard (applies to corner lots) is 30 feet, and the rear yard is 25 feet.
Staff Comment. If retained, the existing residence and accessory structure on the site
would not comply with Residential-4 (R-4) setback requirements upon recording of the
short plat. Therefore, staff recommends as a condition of approval, the applicant shall
obtain a demolition permit and complete a final inspection from the City for the
removal of the residence and garage on future Lots 1, 2, and 3 in order to comply with
Residential-4 (R-4) setbacks of the zone prior to final plat approval.
Upon completion of the building demolition, the three (3) proposed lots would provide
adequate area for compliance with the required setback areas for three (3) new single-
family homes. Setbacks for the new structures would be verified at the time of building
permit review.
Compliance not
yet determined
Building Standards: The R-4 zone has a maximum building coverage of 35% and a
maximum impervious surface coverage of 50%. In the R-4 zone, a maximum building
height of 3 stories with a wall plate height of 32 feet is permitted . Roofs with a pitch
equal to or greater than 4:12 may project an additional six (6) vertical feet from the
maximum wall plate height. If the height of wall plates on a building are less than the
states maximum the roof may project higher to account for the difference, yet the
combined height of both features shall not exceed the combined maximums. Common
rooftop features, such as chimneys, may project an additional four (4) vertical feet
from the roof surface. Non-exempt vertical projections (e.g., roofs pitched less than
4:12, decks, railings, etc.) may extend up to six (6) vertical feet above the maximum
wall plate height if the projection is stepped back one-and-a-half (1.5) horizontal feet
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 7 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
from each minimum building setback line for each one (1) vertical foot above the
maximum wall plate height.
Wall plates supporting a primary roof surface that has only one (1) sloping plane (e.g.,
shed roof) may exceed the stated maximum if the average of wall plate heights is equal
or less than the maximum wall plate height allowed.
Staff Comment: Building height, building coverage, and impervious surface coverage
for the new single-family residences would be verified at the time of building permit
review.
Compliant if
conditions of
approval are
met
Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot
landscape strip along all public street frontages. Minimum planting strip widths
between the curb and sidewalk are established according to the street development
standards of RMC 4-6-060. Street trees and, at a minimum, groundcover shall be
planted within planting strips pursuant to the following standards, provided there shall
be a minimum of one street tree planted per lot.
A. Trees shall be selected from the City’s Approved Street Tree List based on the width
of the planting strip and the presence or lack of overhead power lines; provided, the
Administrator and City arborist shall each retain the right to reject any proposed
cultivar regardless of whether or not the cultivar is on the City’s Approved Street Tree
List.
b. Street trees shall have a minimum caliper of two inches (2”), and be planted
pursuant to the standards promulgated by the City, which may require root barriers,
structured soils, or other measures to help prevent tree roots from damaging
infrastructure.
c. Street trees shall be planted in the center of the planting strip between the curb and
the sidewalk at the following intervals; provided, that, where right-of-way is
constrained, irregular intervals and slight increases or decreases may be permitted or
required. Additionally, trees shall be planted in locations that meet required spacing
distances from facilities located in the right-of-way including, but not limited to,
underground utilities, street lights, utility poles, traffic signs, fire hydrants, and
driveways; such spacing standards are identified in the City’s Approved Tree List.
Generally, the following spacing is required:
i. Small-sized maturing trees: thirty feet (30’) on center;
ii. Medium-sized maturing trees: forty feet (40’) on center; and
iii. Large-sized maturing trees: fifty feet (50’) on center.
Such landscaping shall be at least ten feet (10’) in width as measured from the street
right-of-way. Standards for planting shall be as follows:
a. Trees shall be two inches (2”) in diameter at breast height (dbh) for multi-
family, commercial, and industrial uses at an average minimum rate of one
tree per thirty (30) lineal feet of street frontage.
b. Shrubs at the minimum rate of one per twenty (20) square feet of landscaped
area. Up to fifty percent (50%) of shrubs may be deciduous.
c. Ground cover in sufficient quantities to provide at least ninety percent (90%)
coverage of the landscaped area within three (3) years of installation
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 8 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
All of the landscaped area that is not planted with trees and shrubs or covered with a
tree grate must be planted in ground cover plants, which may include grasses. Mulch
must be confined to areas underneath plants and is not a substitute for ground cover
plants.
Ground cover plants, other than grasses, must be at least the four-inch (4”) pot size,
provided such plants have well-developed roots and are not root bound or J-rooted;
alternative standards may be applied pursuant to RMC 4-4-070C. Area planted in
ground cover plants, other than grass seed or sod, must be planted in triangular
spacing. Ground cover plants must be planted at a density that will cover the entire
area within three (3) years.
All shrubs must be of sufficient size and number to meet the required standards within
three (3) years of planting. Shrubs must be at least a two (2) gallon container size at
planting. Shrubs shall be in beds that include a layer of mulch at least two inches (2”)
in depth.
Broadleaf trees must be a minimum of two-inch (2”) caliper. Conifer trees at the time
of planting must be fully branched and a minimum of six feet (6’) in height.
Except for trees with a tree grate, trees shall include a mulch ring that has a depth of
at least three inches (3”) and is at least three feet (3’) in radius around the tree.
For stormwater ponds, a landscaping strip with a minimum fifteen feet (15’) of width
shall be located on the outside of the perimeter fence, unless otherwise determined
through the site plan review or subdivision review process.
Staff Comment: A Conceptual Landscape Plan prepared by Varley Varley Varley was
submitted with the project application materials (Exhibit 5). Two (2) main elements are
proposed as part of the landscape plan including the modification of an existing 10-
foot wide on-site landscape strip along the street frontage of NE 7th Pl and Nile Ave NE,
and the modification of the existing 8-foot wide off-site planter strip between the
existing sidewalk and the street. The existing parcel proposed for subdivision was part
of the part of the Weston Heights North Short Plat (LUA16-000140) approved in 2016.
As such, frontage improvements were recently installed in the NE 7th Pl and Nile Ave
NE ROWs adjacent to site as part of the earlier short plat. Improvements installed along
the subject parcel frontage include a five-foot (5’) sidewalk with ADA ramps, three (3)
street lights, and an eight-foot planter strip with approximately eleven (11) trees of
various species. Due to the need for new curb cuts and utility connections for the
planned single-family homes, the applicant has proposed the removal of four (4)
deciduous street trees in the ROW. If the recommended condition of approval under
FOF 15: Zoning Development Standard Compliance, Parking is approved, one less tree
would need to be removed (in front of proposed Lot 3) resulting in the removal of three
(3) total trees. As shown in the Landscape Plan, no street trees would be located in
front of proposed Lot 1 if the single existing tree is removed. Therefore staff
recommends, as a condition of approval, the applicant shall install one new street in
the ROW adjacent to proposed Lot 1. The tree species shall be selected from the City
of Renton’s Approved Street Tree list and be approved by the Current Planning Project
Manager at the time of civil construction permit review. Alternatively, the applicant
may retain the existing street tree located in front of proposed Lot 1.
A Plant Schedule included on the Landscape Plan identifies a variety of trees, shrubs,
and ground cover the applicant intends to install within the 10-foot onsite landscape
strip in order to supplement the existing landscaping. Species proposed includes
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 9 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
Viburnum, Evergreen azalea, Maiden grass, and Kinnikinic grass. The plan also
identifies two (2) Serbian spruce, eight (8) Honey locust, two (2) Flowering pear, and
one Red maple to be installed in the front yards of the three (3) new lots. Once the new
plants are installed, the project is anticipated to comply with the on -site landscape
requirements. Landscaping compliance for each lot would be reviewed at the time of
individual building permit application review.
The proposed vault would be fully underground and therefore would not be required
to provide perimeter landscaping. However, the applicant shall concentrate
replacement trees within the tract if feasible in order provide better prote ction and
increase the chances of surviving. Shrubs and other ground cover should also be
provided in order to increase the vegetation on the site and provide a level of screening
between the vault area and the properties to the south. Therefore, staff recommends,
as a condition of approval, the applicant shall install replacement trees within the tract
if feasible, and shall plant shrubs and other ground cover around the perimeter of the
tract where feasible. An updated landscape plan incorporating the additional
vegetation shall be submitted with the civil construction permit application for review
and approval by the Current Planning Project Manager.
Compliant if
condition of
approval is met
Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations (4-
4-130) require the retention of 30 percent of trees in a residential development. Tree
credit requirements shall apply at a minimum rate of thirty (30) credits per net acre.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy;
significant trees on slopes greater than twenty percent (20%); significant trees
adjacent to critical areas and their associated buffers; and significant trees over sixty
feet (60') in height or greater than eighteen inches (18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved;
other significant native evergreen or deciduous trees; and other significant non- native
trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have
been evaluated for retention and are not able to be retained, unless the alders and/
or cottonwoods are used as part of an approved enhancement project within a critical
area or its buffer.
Staff Comment: An Arborist Report, prepared by Layton Tree Consulting., dated April
14, 2022, (Exhibit 6) was submitted with the land use application materials. The City’s
adopted Tree Retention Regulations require a retention percentage of thirty percent
(30%) of onsite significant trees (after the deduction of trees within areas of public
right-of-way dedication and critical areas and buffers). According to the submitted
arborist report, there are a total of five (5) significant trees on the project site, all of
which are rated as “fair” condition. The trees range in size from 10 to 23-inch diameter
DBH and include three (3) apple, one (1) cherry, and one (1) pear tree. During review,
staff discovered that the arborist report contains discrepancies regarding the specific
number of trees on the site. For example, while the arborist report and tree retention
worksheet (Exhibit 5) identify a total of five (5) trees on the site, the tree retention plan
appears to identify at least six (6) additional trees located along the north side of the
site that were installed as part of the Weston Heights North subdivision, with five (5)
proposed for removal. However, the Tree Retention Plan (Exhibit 5) identifies a total of
seven (7) trees for retention. If the Tree Retention Plan is accurate, the proposal would
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 10 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
include the removal of nine (9) total trees, with two (2) trees retained. A proposal to
retain two (2) significant trees would result in a retention percentage of eighteen
percent (18%), which is less than the 30% on-site retention rate required for residential
developments. Retained trees within a subdivision are required to preserved in the
priority order listed in RMC 4-4-130.H.2.a., which includes four (4) specific tiers of
preservation. As such, staff recommends, as a condition of approval, the applicant shall
submit an updated tree retention plan, arborist report, and tree retention worksheet
that correctly identify the number of existing trees on the site and demonstrate
compliance with the Tree Retention and Land Clearing Regulations in RMC 4 -4-130.
The applicant shall utilize the tree preserv ation priority tiers outlined in RMC 4-4-
130.H.2.a to identify the specific trees to be retained. The applicant shall submit a
narrative describing how all reasonable efforts have been taken to preserve trees
utilizing the highest priority tier possible. The updated documents and narrative shall
be reviewed and approved by the Current Planning Project Manager prior to issuance
of the civil construction permit.
The City’s Tree Retention Regulations also require that a minimum tree density of 30
credits per net acre. Due to the discrepancies in the arborist report identified above,
staff could not confirm compliance with the minimum tree density requirement.
Therefore, staff recommends, as a condition of approval, the applicant shall submit an
updated arborist report and tree retention plan that clearly identifies the trees
proposed for retention and demonstrates compliance with the minimum tree density
requirement for residentially zoned lots. The updated arborist report and tree retention
plan shall be reviewed and approved by the Current Planning Project Manager prior to
issuance of the civil construction permit.
Compliant if
Condition of
Approval is
Met
Parking: Parking regulations require that a minimum of two (2) parking spaces be
provided for each detached dwelling.
Driveway cuts are required to be a minimum of 5 feet from property lines and new
driveways may be a maximum of 16 feet in width at the property line. Maximum
driveway slopes shall not exceed fifteen percent (15%); provided, that driveways
exceeding eight percent (8%) shall provide slotted drains at the lower end with
positive drainage discharge to restrict runoff from entering the garage/residence or
crossing any public sidewalk.
Staff Comment: The proposed lots would provide adequate area to accommodate the
two (2) required parking spaces. The applicant proposes to access the three (3) new
lots via individual driveways off of NE 7th Pl. An existing curb cut is located on off of
Nile Ave NE and is currently utilized to access the existing home. Utilizing the existing
curb cut off of Nile AVE NE for access to proposed Lot 3 would reduce the impact to
established landscaping in the frontage improvements along NE 7th Pl constructed in
2016 as part of the neighboring Weston Heights short plat and limit the impact to the
existing sidewalk in NE 7th Pl. In addition, locating the garage off of Nile Ave NE
adjacent to the curb cut allows for greater design flexibility for the future home on Lot,
which will need to meet the corner lot residential design requirements. Therefore, staff
recommends, as a condition of approval, the applicant shall utilize the existing curb cut
off of Nile Ave NE to access the single-family home on proposed Lot 3.
Compliance with the driveway standards for the new lots would be verified at the time
of formal building permit application review.
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 11 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
Compliance
not yet
demonstrated
Fences and Retaining Walls: In any residential district, the maximum height of any
fence, hedge or retaining wall shall be seventy two inches (72"). Except in the front
yard and side yard along a street setback where the fence shall not exceed forty eight
inches (48") in height.
There shall be a minimum three-foot (3') landscaped setback at the base of retaining
walls abutting public rights-of-way.
Staff Comment: No new retaining walls or fences were identified on the submitted
plans (Exhibit 2) included with the short plat application materials. An existing six-foot
tall wood fence is located around the perimeter of the property and is proposed for
partial retention. It appears that portions of the fence may exceed the forty-eight inch
(48”) height limit in the front yard setback. New or existing fences would be evaluated
for compliance with the code at the time of formal building permit review.
16. Design Standards: Residential Design and Open Space Standards (RMC 4-2-115) are applicable in the R-4,
R-6, R-8 zone. The Standards implement policies established in the Land Use Element of the
Comprehensive Plan. Compliance with Site Design Standards must be demonstrated prior to approval of
the subdivision. Compliance with Residential Design Standards would be verified prior to issuance of the
building permit for the new single-family homes. The proposal is consistent with the following design
standards, unless noted otherwise:
Compliance Design Standards R-4 and Analysis
N/A
Lot Configuration: Staff Comment: Lot configuration standards are not applicable in
the R-4 zone.
✓
Lots shall be configured to achieve both of the following:
1. The location of stormwater infiltration LID facilities is optimized, consistent
with the Surface Water Design Manual. Building and property line setbacks are
specified in the Surface Water Design Manual for infiltration facilities.
2. Soils with good infiltration potential for stormwater management are
preserved to the maximum extent practicable as defined by the Surface Water
Design Manual.
Staff Comment: See drainage discussion below under FOF 19.
Compliance
not yet
demonstrated
Garages: If an attached garage is wider than twenty six feet (26’), at least one (1) garage
door shall be recessed a minimum of four feet (4’) from the other garage door.
Additionally, one of the following is required:
1. The front porch projects in front of the garage a minimum of five feet (5’), and
is a minimum of twelve feet (12’) wide, or
2. The roof extends at least five feet (5') (not including eaves) beyond the front of
the garage for at least the width of the garage plus the porch/stoop area, or
3. The garage is alley accessed, or
4. The garage entry does not face a public and/or private street or an access
easement, or
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 12 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
5. The garage width represents no greater than fifty percent (50%) of the width
of the front facade at ground level, or
6. The garage is detached, or
7. The garage doors contain a minimum of thirty percent (30%) glazing,
architectural detailing (e.g. trim and hardware), and are recessed from the
front façade a minimum of five feet (5’), and from the front porch a minimum
of seven feet (7’).
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Primary Entry: The entry shall include a porch or stoop with a minimum depth of five
feet (5') and minimum height of twelve inches (12") above grade.
Exception: in cases where accessibility (ADA) is a priority, an accessible route may be
taken from a front driveway.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Facade Modulation: One of the following is required:
1. An offset of at least one story that is at least ten feet (10') wide and two feet
(2') in depth on facades visible from the street, or
2. At least two feet (2') offset of second story from first story on one street facing
facade.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Windows and Doors: Windows and doors shall constitute twenty-five percent (25%) of
all facades facing street frontage or public spaces.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Scale, Bulk, and Character: A variety of elevations and models that demonstrate a
variety of floor plans, home sizes, and character shall be used. All of the following are
required:
1. A variety of elevations and models that demonstrate a variety of home sizes,
character, and a diverse streetscape.
2. Abutting, adjacent, and diagonal houses must have differing architectural
elevations.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Roofs: A variety of roof forms appropriate to the style of the home shall be used.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 13 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
Compliance
not yet
demonstrated
Eaves: Both of the following are required:
1. Eaves projecting from the roof of the entire building at least twelve inches (12")
with horizontal fascia or fascia gutter at least five inches (5") deep on the face
of all eaves, and
2. Rakes on gable ends must extend a minimum of two inches (2") from the
surface of exterior siding materials.
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Architectural Detailing: If one siding material is used on any side of the dwelling that is
two stories or greater in height, a horizontal band that measures at least eight inches
(8") is required between the first and second story.
Additionally, one of the following is required:
1. Three and one half inch (3 1/2") minimum trim surrounds all windows and
details all doors, or
2. A combination of shutters and three and one half inches (3 1/2") minimum trim
details all windows, and three and one half inches (3 1/2") minimum trim
details all doors.
Staff Comment: Compliance for this standard would be verified a t the time of building
permit review.
Compliance
not yet
demonstrated
Materials and Color: For subdivisions and short plats, abutting homes shall be of
differing color. Color palettes for all new dwellings, coded to the home elevations, shall
be submitted for approval.
Additionally, one of the following is required:
1. A minimum of two (2) colors is used on the home (body with different color
trim is acceptable), or
2. A minimum of two (2) differing siding materials (horizontal siding and shingles,
siding and masonry or masonry-like material, etc.) is used on the home. One
alternative siding material must comprise a minimum of thirty percent (30%)
of the street facing facade. If masonry siding is used, it shall wrap the corners
no less than twenty four inches (24").
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
17. Compliance with Subdivision Regulations: RMC 4-7 Provides review criteria for the subdivisions. The
proposal is consistent with the following subdivision regulations if all conditions of approval are complied
with:
Compliance Subdivision Regulations and Analysis
Compliant if
condition of
approval
under FOF 15:
Access: Each lot must have access to a public street or road. Access may be by a shared
driveway per the requirements of RMC 4-6-060 Street Standards.
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 14 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
Zoning
Compliance,
Parking is met
The maximum width of single loaded garage driveways shall not exceed nine feet (9')
and double loaded garage driveways shall not exceed sixteen feet (16').
Staff Comment: The applicant is proposing to access each lot with individual driveways
off of NE 7th Pl. Driveways shall be designed in accordance with RMC 4-4-080. See FOF
15 ‘Parking’ for additional driveway analysis and one (1) recommended condition of
approval related to location of the driveway for Lot 3.
N/A
Blocks: Blocks shall be deep enough to allow two (2) tiers of lots.
Staff Comment: Not applicable, no blocks are proposed.
✓
Lots: The size, shape, orientation, and arrangement of the proposed lots comply with
the requirements of the Subdivision Regulations and the Development Standards of the
R-4 zone and allow for reasonable infill of developable land.
All of the proposed lots shall meet the requirements for minimum lot size, depth, and
width.
Width between side lot lines at their foremost points (i.e., the points where the side lot
lines intersect with the street right-of-way line) shall not be less than eighty percent
(80%) of the required lot width except in the cases of (1) pipestem lots (or flag lot),
which shall have a minimum width of twenty feet (20') and (2) lots on a street curve or
the turning circle of cul-de-sac (radial lots), which shall be a minimum of thirty five feet
(35').
No residentially zoned lot shall have a depth-to-width ratio greater than four-to-one
(4:1).
Flag lots may be permitted for new plats to achieve the minimum density within the
Zoning Code when there is no other feasible alternative to achieving the minimum
density.
Staff Comment: Proposed Lots 1, 2, and 3 meet the minimum lot dimensional
requirements in the R-4 zone. All three (3) lots have a depth-to-width ratio of less than
four-to-one and no flag lots are proposed. Lastly, the distance between the side lot lines
at their foremost points exceed 80% of the required lot width (80% of 70 feet = 64 feet)
for all three (3) lots, which range from 70 feet to 87.4 feet wide at the ROW.
✓
Streets: The proposed street system shall extend and create connections between
existing streets per the Street Standards outlined in RMC 4-6-060 Street Standards.
Staff Comment: Primary access to the site is proposed via NE 7th Pl, an existing public
street with an existing ROW width of approximately 53 to 67 feet. The street meets the
City’s complete street standards for a residential access street and no new
improvements or dedication is required.
Payment of a transportation impact fee would be required for the construction of each
new single-family home prior to building permit issuance.
✓
Relationship to Existing Uses: The proposed project is compatible with existing
surrounding uses.
Staff Comment: The proposed lots are generally rectangular in shape and would provide
adequate area to allow for the construction of single-family residences consistent with
other existing residences within the surrounding R-4 zone. The proposal is similar to
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 15 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
18. Modification Analysis: The applicant is requesting an Administrative Modification from RMC 4-6-090
Utility Lines – Underground Requirements in order grant relief from the requirement to underground all
overhead utilities along the site’s frontage (Exhibit 10). The applicant has proposed to retain the existing
overhead utility lines in the Nile Ave NE ROW. The proposal is compliant with the following modification
criteria, pursuant to RMC 4-9-250, if all conditions of approval are met. Therefore, staff is recommending
approval of the requested modification:
Compliance Street Modification Criteria and Analysis
✓
a. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and the
proposed modification is the minimum adjustment necessary to implement these
policies and objectives.
Staff Comment: The Land Use Element has applicable policies listed under a separate
section labeled Promoting a Safe, Healthy, and Attractive Community. These policies
address walkable neighborhoods, safety, and shared uses. The intent of the policies is to
promote new development with walkable places that support grid and flexible grid street
and pathway patterns, and are visually attractive, safe, and he althy environments. The
requested modification is consistent with these policy guidelines.
✓
b. Will meet the objectives and safety, function, appearance, environmental
protection, and maintainability intended by the Code requirements, based upon
sound engineering judgment.
Staff Comment: The applicant contends that the existing power poles on Nile Ave NE are
fully functional, easily accessible, and provide no safety or environmental danger to the
public. The poles are part of larger two -mile section of overhead power poles along Nile
Ave NE that extends north of the site to SE May Valley Rd. Staff concurs with the
applicants justification.
✓
c. Will not create substantial adverse impacts to other property(ies) in the vicinity
Staff Comment: The applicant contends that the modified improvements proposed by the
applicant are consistent with the existing utility pattern along Nile Ave NE, which
primarily consists of overhead lines. In addition, the applicant contends that temporary
construction and traffic impacts created by the undergrounding work would be more
impactful to the surrounding residents than retention of the overhead lines. While staff
does not concur that the undergrounding construction work would be particularly
impactful to the neighbors, the retention of the overhead lines that have been in place
for a significant period of time would not be injurious to properties in the vicinity as it
would not change the urban landscape.
✓
d. Conforms to the intent and purpose of the Code.
Staff Comment: The applicant acknowledges that the intent of the undergrounding
requirements in RMC 4-6-090 is to lower maintenance costs for the providers as well as
to improve street aesthetics, but contends that the site’s minimal street frontage along
Nile Ave NE (approximately 140 feet) compared to the larger stretch of ROW with
overhead lines on Nile Ave NE between NE 7th Pl and SE May Valley Rd limits the
modifications impact to both maintenance and aesthetics. The applicant contends that
existing development patterns in the area and is consistent with the Comprehensive
Plan and Zoning Code, which encourage residential infill development.
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 16 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
the requirement to underground a small section of roadway, a section that has recently
been improved with new sidewalk and street trees as part of a different project (Weston
Heights North Short Plat, LUA16-000140), would have a minimal impact to future
maintenance or aesthetics and therefore conforms to the intent and purpose of the code.
Staff concurs with the applicant’s justification and finds that the proposed modification
conforms to the intent and purpose of the Code.
✓
e. Can be shown to be justified and required for the use and situation intended; and
Staff Comment: See comments under criterion ‘b’.
19. Availability and Impact on Public Services:
Compliance Availability and Impact on Public Services Analysis
✓
Police and Fire: Police and Fire Prevention staff indicates that sufficient resources exist
to furnish services to the proposed development; subject to the condition that the
applicant provides Code required improvements and fees. The 2023 Fire impact fees
are applicable at the rate of $829.77 per single-family unit and is calculated and paid at
time of building permit issuance.
✓
Schools: It is anticipated that the Issaquah School District can accommodate any
additional students generated by this proposal at the following schools: Apollo
Elementary, Maywood Middle School and Liberty High School. Any new students from
the proposed development would be bussed to their schools. The stop is located
directly in front of the project site at the intersection of Nile Ave NE and NE 7th Pl., which
contains a sidewalk and planter strip.
A School Impact Fee, based on new single-family lots, will be required in order to
mitigate the proposal’s potential impacts to the Issaquah School District. The fee is
payable to the City as specified by the Renton Municipal Code. The 2023 School Impact
fee is assessed at $11,377.00 (+5% administrative fee) per single-family residence and
is calculated and paid at time of building permit issuance.
✓
Parks: A Park Impact Fee would be required for the future houses. The 2023 Park Impact
Fee is assessed at $3,276.44 per single-family residence and is calculated and paid at
time of building permit issuance.
Compliance
not yet
demonstrated
Storm Water: An adequate drainage system shall be provided for the proper drainage
of all surface water.
Staff Comment: A preliminary technical information report (TIR) prepared by Encompass
Engineering, dated November 2, 2022 and revised March 1, 2023, was submitted by the
applicant. Based on the City of Renton’s flow control map, the site falls within the Flow
Control Duration Standard- Matching Forested and is within the Lower Cedar River
Drainage Basin. The report is based on a Full drainage review and Core Requirements 1
thru 9 and the six (6) Special Requirements have been discussed in the Technical
Information Report.
The applicant also submitted a Geotechnical Evaluation prepared by Cobalt Geosciences
and dated October 4, 2021. The results of the evaluation found that full infiltration was
not feasible on the site due to the presence of weathered and unweathered glacier till in
various areas of the site. However, the consultant determined that limited infiltration is
feasible due to the presence of loamy sand on the site, provided an overflow system is
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 17 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
provided. To allow for infiltration, the applicant has proposed three (3) 100 sq. ft. gravel
filled trenches, or one on each of the three (3) new lots.
Non-infiltrating stormwater runoff from the three (3) lots will be collected and conveyed
to an 88-foot by 16-foot CMP Detention Tank with a 78-inch diameter, to be located
within a stormwater tract in the southwest corner of the site. Water collected in the tank
will be discharged via a control structure to a proposed manhole located on Nile Ave NE .
Compliance with the 2022 Renton Surface Water Design Manual would be verified at
the time of formal building permit review for the new single-family homes civil
construction permit application
✓ Water: Water service is provided by the King County Water District 90. A water
availability certificate was provided by the applicant.
✓
Sanitary Sewer: Wastewater service is provided by the City of Renton. Two new sewer
stubs connecting to the existing 8’’ sewer main in NE 7th Pl are proposed to serve Lots 2
and 3. An existing sewer stub serving the existing house on proposed Lot 1 would be
utilized by the new home on future Lot 1.
The 2023 fee for a 1-inch meter install is $3,500.00 per meter. In addition, the project
will be subject to the East Renton Interceptor Special Assessment District fee. The fee is
assessed at $316.80 per lot. The SAD fee for the existing lot has already been paid,
therefore one of the new lots will be credited.
I. CONCLUSIONS:
1. The subject site is located in the Residential Low Density (LD) Comprehensive Plan designation and
complies with the goals and policies established with this designation, see FOF 14.
2. The subject site is located in the Residential-4 (R-4) zoning designation and complies with the zoning and
development standards established with this designation provided the applicant complies with City Code
and conditions of approval, see FOF 15.
3. Compliance of the proposed Short Plat with the Residential Design and Open Space Standards could not
be demonstrated at this time, but would be verified during review of the single-family building permit
application, see FOF 16.
4. The proposed Short Plat complied with the subdivision regulations as established by City Code and state
law provided the project complies with all advisory notes and conditions contained herein, see FOF 17.
5. The proposed Short Plat complied with the street standards as established by City Code, provided the
project complies with all advisory notes and conditions of approval contained herein, see FOF 18 and 19.
6. There are safe walking routes to the school bus stop, see FOF 19.
7. There are adequate public services and facilities to accommodate the proposed single-family homes, see
FOF 19.
8. Key features which are integral to this project include the retention and preservation of existing ROW
landscaping, limiting new driveway curb cuts, and protecting off-site trees from impacts during
construction.
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 18 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
J. DECISION:
The Sierra Homes Short Plat, File No. LUA22-000427, SHPL-A, MOD, as depicted in Exhibit 2, is approved and is
subject to the following conditions:
1. The applicant shall obtain a demolition permit and complete a final inspection from the City for the
removal of the residence and garage on future Lots 1, 2, and 3 in order to comply with Residential -4 (R-4)
setbacks of the zone prior to final plat approval.
2. The applicant shall install one new street in the ROW adjacent to proposed Lot 1. The tree species shall
be selected from the City of Renton’s Approved Street Tree list and be approved by the Current Planning
Project Manager at the time of civil construction permit review. Alternatively, the applicant may retain
the existing street tree located in front of proposed Lot 1.
3. The applicant shall install replacement trees within the tract if feasible, and shall plant shrubs and other
ground cover around the perimeter of the tract where feasible. An updated landscape plan incorporating
the additional vegetation shall be submitted with the civil construction permit application for review and
approval by the Current Planning Project Manager.
4. The applicant shall submit an updated tree retention plan, arborist report, and tree retention worksheet
that correctly identify the number of existing trees on the site and demonstrate compliance with the Tree
Retention and Land Clearing Regulations in RMC 4-4-130. The applicant shall utilize the tree preservation
priority tiers outlined in RMC 4-4-130.H.2.a to identify the specific trees to be retained. The applicant shall
submit a narrative describing how all reasonable efforts have been taken to preserve tr ees utilizing the
highest priority tier possible. The updated documents and narrative shall be reviewed and approved by
the Current Planning Project Manager prior to issuance of the civil construction permit.
5. The applicant shall submit an updated tree retention plan, arborist report, and tree retention worksheet
that clearly identifies the trees proposed for retention and demonstrates compliance with the minimum
tree density requirement for residentially zoned lots. The updated documents shall be reviewed and
approved by the Current Planning Project Manager prior to issuance of the civil construction permit.
6. The applicant shall utilize the existing curb cut off of Nile Ave NE to access the single -family home on
proposed Lot 3.
DATE OF DECISION ON LAND USE ACTION:
SIGNATURE:
Matt Herrera, Acting Planning Director Date
TRANSMITTED on August 7, 2023 to the Owner/Applicant/Contact:
Owner: Applicant/Contact:
Awesome Yah Church
702 Nile Ave NE
Renton, WA 98059
Ian Dahl, Encompass Engineering & Surveying
165 NE Juniper St, Ste 201
Issaquah WA 9802
idahl@encompasses.net
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
8/7/2023 | 1:26 PM PDT
City of Renton Department of Community & Economic Development
Sierra Homes Short Plat
Administrative Report & Decision
LUA22-000427, SHPL-A, MOD
Report of August 7, 2023 Page 19 of 19
D_Sierra Homes Short Plat Decision_202308012_FIN
TRANSMITTED on August 7, 2023 to the Parties of Record:
Will Wilson
Wrwilson801@gmail.com
5717 NE 7th Pl
Renton, WA 98059
TRANSMITTED on August 7, 2023 to the following:
Vanessa Dolbee, Interim CED Administrator
Brianne Bannwarth, Development Engineering Director
Gina Estep, Economic Development Director
Nate Janders, Development Engineering Manager
Anjela Barton, Fire Marshal
K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION:
The administrative land use decision will become final if the decision is not appealed within 14 days of the decision
date.
APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing
Examiner on or before 5:00 PM on August 21, 2023. An appeal of the decision must be filed within the 14 -day
appeal period (RCW 43.21.C.075(3); WAC 197-11-680). Appeals must be submitted electronically to the City Clerk
at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee,
normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted
electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals
to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process
may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov.
EXPIRATION: The Administrative Short Plat decision will expire five (5) years from the date of decision. A single
one (1) year extension may be requested pursuant to RMC 4-7-070.M.
RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by
the approval body. The approval body may modify his decision if material evidence not readily discoverable prior
to the original decision is found or if he finds there was misrepresentation of fact. After review of the
reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will
be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal
within the 14-day appeal time frame.
THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may
occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the
Hearing Examiner as well. All communications after the decision/approval date must be made in writing through
the Hearing Examiner. All communications are public record and this permits all interested parties to know the
contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of
this doctrine could result in the invalidation of the appeal by the Court.
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129
CITY OF RENTON
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT
ADMINISTRATIVE REPORT & DECISION
EXHIBITS
Project Name:
Sierra Homes Short Plat
Land Use File Number:
LUA22-000315 SHPL-A
Date of Report
Error! Reference
source not found.
Staff Contact
Alex Morganroth
Senior Planner
Project Contact/Applicant
Ian Dahl, Encompass
Engineering & Surveying /165
NE Juniper St, Ste 201,
Issaquah WA 98027/
idahl@encompasses.net
Project Location
702 Nile Ave NE (APN
1123059002)
The following exhibits are included with the Administrative report:
Exhibit 1: Administrative Decision
Exhibit 2: Preliminary Plat Plan
Exhibit 3: Neighborhood Detail Map
Exhibit 4: Civil Plan Set
Exhibit 5: Landscape Plan, Tree Retention Plan, and Worksheet
Exhibit 6: Arborist Report, prepared by Layton Tree Consulting, LLC, dated April 14, 2022, revised
October 26, 2022
Exhibit 7: Technical Information Report (TIR), prepared by Jacobson Consulting Engineer, dated
April 24, 2023
Exhibit 8: Geotechnical Report, prepared by Cobalt Geosciences, dated October 4, 2021
Exhibit 9: Wetland Reconnaissance, prepared by Altmann Oliver Associates, LLC, dated
December 10, 2021
Exhibit 10: Modification Request
Exhibit 11: Advisory Notes
Exhibit 12: Public Comment, Wilson
DocuSign Envelope ID: E8F3519A-7ED6-45DC-9D09-CCC7C7005129