Loading...
HomeMy WebLinkAboutWWP273145As, 0� CITY OF RENTON ♦ ♦ 1055 S. GRADY WAY RENTON, WA 98055 INV VENDOR: 068180 RH2 ENGINEERING INC 12100 NE 195TH ST #100 BOTHELL, WA 98011-5111 FOB Point: Terms: net term Req_ Del. Date: Special Inst: IILL TO: Page 1 1 2/18/04 18/0000517 SHIP TO: Req. No.: Dept.: PLNG/BLDG/PUB WKS UTILITY SYS contact: PHELAN, TERESA Pre -Assigned PO#?: NO CAG-04-019, Water & WW SCADA Upgrade, CAG-04-019, Water & WW Scada Upgrade, /iQ_SL__1. " _ 51 ZU - v l C J�s1, , 7j F 18,101.35 7.000.00 SUBTOTAL 25,101.35 TAX 0.00 FREIGHT 0.00 TOTAL 25,101.35 E 421.000400.018.5960.0035.65.045065 I IMM 5065/5160 E 421.000500.018.5960.0034.65.055120 5121/5160 Authorized Signature Authorized Signature RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400 / (800) 720-8052 Fax: (425) 398-2774 ov'CD CITY OF RENTON Invoice uTu-T-Y SYS-, EIA4�q To: City of Renton Invoice Number 39240 1055 South Grady Way Invoice Date: October 11, 2004 Renton, WA 98055 Attention: Teresa Phelan Project: 104044 Water System SCADA Upgrade Project Manager: Mark Miller Professional Services for the Period: 8/30/2004 to 9/26/2004 Billing Group: 01 Water System SCADA Upgrades [103] HMI Changes Professional Services Billing Hours Billing Rate Amount Professional IV Lee Tumbleson DATE 17.00 103.36 1,757.12 M E INIo�ATFanalI ervices Total: 17.00 $1,757.12 Reimbursables Amount Mileage 64.13 Re rsables Total: $64.13 HMI Changes Totals: $1,821.25 [105] Project Management Professional Services Billing Hours Billing Rate Amount Professional V QWNIRW116, LAWS OF 1965 1.25 121.60 152.00 CITY OF RENTON CERTIFICATION I. THE UNDERSIGNED DO HEREBY CERTIFY UNDER PENALTY Professional Services Total: 1.25 $152.00 OF PERJURY, THAT THE MATERIALS HAVE BEEN KFAIM, THE SERVICES RENDERED OR THE LABOR PERFORM AS DESCRIBED HEREIN, AND THAT THE CLAIM IS JUST, Dt)EAND Project Management Totals: $152.00 UNPAID OQLIGATION AGAINST THE CITY OF RENTON, AND THAT !AMA THOR!ZED TO AUTHENTICATE ANC CERTIFY TO SAID CLAIM. & SIGNED: Moth/ Billing Group Total. $1,973.25 Billing Group: 02 Fixed Fee Page 1 RH2 Engineering, Inc. Project: 104044 Monday, October 11, 2004 Invoice. 39240 Project Totals: Contract Amount: Percent Complete: Fee Earned: Prior Fee Billings: Current Fee Total: Billing Group Subtotal: Billing Group Total. $2,646.36 85.00% $2,249.41 1,587.82 $661.59 661.59 $661.59 *** Total Project Invoice Amount. $2,634.84 Billing Summary, Budget Prior Billed Current Invoice Budeet Remaining $25,101.35 13,214.50 $2,634.84 $9,252.01 Page 2 R1-12 Engineering; Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400; (800) 720-8052 Fax: (425) 398-2774 Billing Documentation To: City of Renton Date: October 11, 2004 1055 South Grady Way Invoice: 39240 Renton, WA 98055 Project: 104044 Water System SCADA Upgrade Manager: Mark Miller Professional Services for the Period: 8/30/2004 to 9/26/2004 Billing Group: 01 Water System SCADA Upgrades Hours 103 - HMI Changes Lee Tumbleson 9/2/2004 Configuring new SCADA software. 3.00 9/20/2004 Configuring ActiveFactory clients at City Hall. Working with City IS staff to 9.00 enable firewall access to the SCADA server from City Hall. 9/21/2004 Completing ActiveFactory configuration after City IS staff completed firewall 3.00 configuration. 9/22/2004 Working with Wonderware to determine delta data retrieval and configuration 2.00 for eliminating NULL entries in data. Lee Tumbleson Total: 17.00 103 - HMI Changes Total: 17.00 105 - Project Management Mark Miller 9/9/2004 Discuss features of new software with City and Lee T. 1.00 9/10/2004 Draft invoice review. 0.25 Mark Miller Total: 1.25 105 - Project Management Total: 1.25 Total Professional Services 18.25 Billing Group: 02 Fixed Fee Hours Rh2 Engineering, Inc. Project: 104044 Invoice: 39240 October 1 I , 2004 O& " Or zr�t Page 2 of 2 Hours Systems Interface In c. 22125 17th Avenue SE Suite 111, Bothell, WA 98021 USA Phn: (425) 481-1225 Fax (425) 481-2115 Packing List S City of Renton S City of Renton O 1055 South Grady Way H 1055 South Grady Way p Renton, WA 98055 P Renton, WA 98055 T T Ph: 425-430-7206 O O Order Date: Customer Order: Sill Project Number: 02/03/09 18/0001623 S09B08 Ship Date: Shipped Via: Customer Job: 03/20/09 SII Truck uantity Prev Ship Item Ordered Ship Now B/O Description 1 1 1 CONTROLPANEL SII S/N S091308A 2 1 1 UPS, 750VA, 230V P/N PW5115 3 1 1 BATTERY, 12VDC, 7.2 AMPS, SEALED LEAD ACID P/N SLA1104 Signature Date Print Name 11.1AA^-- S09B08P1.doc Page 1 of 1 12-22-2008 Do you operate a Radio system under Part 90? Take Note! FCC Refarming activity began in 1996 and is soon coming to fruition. What is Refarming? This is a term referring to the reorganization of the Spectrum below 800 MHz with the goal of creating additional frequency channels. This comes at the expense of narrower channel bandwidth for current licensees however. So, if you are now operating 25KHz equipment on the old 25 KHz channels, you have until January 1, 2013 to convert to Narrowband equipment! Here is the timetable to follow: • January 1, 2011 — All new applications for frequency assignments must have a maximum bandwidth of 12.5 Kilohertz. • January 1, 2011 — All modifications to existing licenses that expand the service contour of existing licenses must have a bandwidth of 12.5 KHz or less • January 1, 2011— ALL manufacturing of 25 Kilohertz capable equipment is to cease. • January 1, 2013 —ALL current licensees must be fully operational on 12.5 Kilohertz equipment. Links to FCC Documents: hftp://hraunfoss.fcc.gov/edocs public/attachmatch/FCC-04-292A1.doc hftp://hraunfoss.fcc.gov/edocs public/attachmatch/FCC-04-292A1.pdf http://hraunfoss.fcc.gov/edocs public/attachmatch/FCC-04-292A1.txt What This Means To Users All existing Part 90 radio systems operating on frequencies between 150-512 MHz have 5 years to convert those systems either to 12.5 kHz bandwidth or to a technology that provides one voice path per 12.5 kHz of bandwidth or provides a data rate of 4800 bps/6.25 kHz. 12.5 kHz Conversion Deadline for Existing VHF/UHF Systems • January 1, 2013 - Industrial/Business Pool licensees conversion deadline. • January 1, 2013 - Public Safety Pool licensees conversion deadline. o After this date, all systems must have converted either to 12.5 kHz bandwidth or to a technology that provides one voice channel per 12.5 kHz or operates at a data rate 4800 bps per 6.25 kHz of bandwidth. Interim Deadlines for VHF/UHF Systems & Equipment • January 1, 2011 - New applications for 25 kHz bandwidth will be accepted until this date. o After this date, applications for greater than 12.5 kHz bandwidth will be accepted only if the equipment meets the efficiency standard of one voice channel/12.5 kHz bandwidth or 4800 bps/6.25 kHz (9600 bps for 12.5 kHz; 19.2 bps for 25 kHz) • January 1, 2011 - Modifications of existing 25 kHz systems will be accepted until this date. o After this date, applications to modifications to 25 kHz systems which result in an expanded service contour will be accepted only if the equipment meets the efficiency standard of one voice channel/12.5 kHz bandwidth or for data, 4800 bps/6.25 kHz (9600 bps for 12.5 kHz; 19.2 Kbps for 25 kHz) • January 1, 2011 - 25 kHz equipment can be manufactured and imported until this date. o After this date, equipment operating at greater than 12.5 kHz bandwidth must meet the efficiency standard of one voice channel/12.5 kHz bandwidth or 4800 bps/6.25 kHz. • 90.2030) has been amended to allow certification of equipment operating at 25 kHz after January 1, 2005 if it meets the efficiency standards listed above. Effective date of 90.203(j)(5) has been stayed until the FCC releases a decision on the Manufacturers Petition for stay. (See next article). The FCC also revised its rules to exempt Part 90 paging -only frequencies from the narrow -banding requirements. In effect, since 25 KHz equipment will no longer be available after January 1, 2011, systems that add mobiles will need to use 12.5 KHz units, forcing the entire system to accommodate narrow band at this point. THIS NEEDS TO BE PLANNED! Narrowband 12.5 KHz units will have difficulty receiving 25 KHz transmissions because the wider bandwidth units will modulate greater than the pass -band of the narrowband receivers. 12.5 KHz units talking to 25 KHz units will be low in volume compared to 25 KHz units. A scheme for phasing this all in needs to be developed in order to avoid system down time. This phasing in is easier to do if all of the equipment in the system share the same capabilities. This won't be possible after January 1, 2008 because of the lack of backward compatibility with 25 KHz systems. If you have any questions or wish to have ACCU-COMM aid in developing your transition plans, please call us and set up a time we can meet to discuss this issue. Michael J. Bingaman President, ACCU-COMM, Inc. Panasonic recommends Windows Vista® Business. toughbook 30 Powerful, Rugged and Wireless Daylight -readable Display 11 Full Magnesium Alloy Case with Handle Shock -mounted, Removable Hard Drive IM Sealed All-weather Design Mobile Broadband- and GPS-ready Design Panasonic DURABILITY FEATURES SOFTWARE CPU STORAGE & MEMORY DISPLAY AUDIO EXPANSION SLOTS MULTIMEDIA POCKET KEYBOARD & INPUT INTERFACE iItlXt�: POWER SUPPLY POWER MANAGEMENT SECURITY FEATURES WARRANTY DIMENSIONS & WEIGHT toughbook 30 Powerful, Rugged and Wireless Panasonic recommends Windows Vista® Business. • Designed using MIL-STD-81 OF test procedures • Full magnesium alloy case with handle • Moisture- and dust -resistant LCD, keyboard and touchpad • Sealed port and connector covers • Shock -mounted, removable hard drive in stainless steel case • Rugged, dust -resistant hinges • Vibration- , shock- and drop -resistant • Pre -installed replaceable screen film for touchscreen protection • Genuine Windows Vista° Business (with XP downgrade option) • Setup, Diagnostics, DMI Viewer, Online Reference Manual, Adobe® Reader, Panasonic Handwriting, Hard Disk Data Erase Utility, Recovery DVD • Inter Core" 2 Duo Processor L7500 - 4MB L2 cache - Processor speed 1.6GHz - 801 FSB • 1024MB SDRAM (DDR2) standard, expandable to 401 • 80GB hard drive (shock -mounted and user -removable) • 13.3" 1024 x 768 Q(GA) transmissive, daylight -readable TFT active matrix color LCD with touchscreen or withouttouchscreen • External video support up to 1280 x 1024 at 16 million colors (24-bit color depth) • InterGM965 integrated video controller max. 384MB (DVMT) VRAM on XP' • Anti -glare, anti -reflective coating • 1000 nit (touchscreen models), 500 nit (non-touchscreen models) LCD brightness • Sigmatel" STAC9751T AC-97 v2.1 Compliant Audio Codec • Intel' high definition audio compliant • Integrated front -facing speaker • Convenient keyboard volume and mute controls •PC card type 11x1 • Secure Digital (SDHC) card • ExpressCard/54 x 1 • Will accept optional Combo or DVD Super MULTI Drive, or 2nd Battery • 87-key with dedicated Windows® key • Pressure -sensitive touchpad with vertical scrolling support • Touchscreen LCD (only with touchscreen version) • Integrated stylus holder (only with touchscreen version) • External video Minim-D-sub 15-pin • Headphones/speaker Mini -jack stereo • Microphone/line in Mini -jack • Port replicator 80-pin (reinforced) • Serial D-sub 9-pin • Ext. antenna conn. 50 Ohm Coaxial • USB 2.0 (x 3) 4-pin • IEEE 1394a (Firewire) 4-pin • 10/100/1000 Ethernet RJ-45 • 56K Modem RJ-11 • Optional integrated mobile broadband (VtMrAN) • Inter Wireless WiFi Link 4965AG 802.11a/b/g • Bluetooth® v.2.0 + EDR • Security -Authentication: LEAP, WPA, 802.1 x, EAP-TLS, EAP-FAST, PEAP - Encryption: CKIP, TKIP, 128-bit and 64-bit WEP, Hardware AES • Slide on/off switch • Lithium ion battery pack (10.1 8550mAh) • Battery operation: 7 hours" • Battery charging time: 5 hours off, 8.5 hours on" • AC Adapter: AC 1 OOV-240V 50/60Hz, Auto sensing/switching worldwide power supply • Pop-up, on -screen battery status reporting • Suspend/Resume Function, Hibernation, Standby, ACPI BIOS • Password Security: Supervisor, User, Hard Disk Lock • Cable lock slot • Trusted platform module (TPM) security chip v.1.2 • Computrace® theft protection agent in BIDS — Fingerprint scanner (option) • SmartCard reader (option) • 3-year limited warranty, parts and labor • 2.8"(H) x 11.9"(W) x 11.3"(D) • 8.4 lbs. • Daylight -readable Display ® Full Magnesium Alloy Case with Handle ® Shock -mounted, Removable Hard Drive • Sealed All-weather Design • Mobile Broadband- and GPS-ready Design INTEGRATED OPTIONS — Mobile Broadband Solutions - EV-DO Rev. A - HSDPA • 120GB hard drive • Global positioning system (GPS) receiver • Backlit keyboard - sealed rubber or plastic emissive • SmartCard reader • Fingerprint scanner • ULI604 Class I, Division 2, Groups A, B, C, D certified model ACCESSORIES—* • AC Adapter (3-pin) CF-AA1653AM • MIL-461 Compliant AC Adapter CF-AA1653ASM • Battery Charger CF-VCBTBI W • Touchscreen Large Stylus with Tether Hole CF-VNP009U • ToughMate ComUniversal Carrying Case (large capacity) COMUNIV-P • ToughMate ComUniversal Jr. Carrying Case COMUNIVJR-P • ToughMate Sling 30 Case TM30-P • Desktop Port Replicator CF-VE8272A2W • Combo Drive (DVD-ROWCD-RWI CF-VDR301U • DVD Super MULTI Drive CF-VDM301 U • External USB Floppy Drive CF-VFDU03U • Lithium Ion Battery Pack CF-VZSU46U • Lithium Ion Battery Pack for Multimedia Pocket CF-VZSU1430U • Memory Cards - 1 GB CF-WMBA601 G - 2GB CF-WRBA602G • Vehicle -mount Port Replicator (USB 2,0) CF-WEB301 M • Vehicle -mount Port Replicator with Integrated Dual High -gain Antenna Pass -through (USB 2.0) CF-WEB30IMB • Vehicle -mount Port Replicator with Integrated Single High -gain Antenna Pass -through (USB 2.0) CF-WEB301MA • 13.3" LCD Protector Film CF-VPF05U 'Total usable memory will be less depending upon actual system configuration. Vista max. VRAM is 251 MB with 1 GB of memory, or 358MB wth 1.5GB or more of memory. "Battery performance features such as charge time and life span can vary according to the conditions under which the computer and battery are used. Battery operation and recharge times will vary based on many factors, including screen brightness, applications, features, power management, battery conditioning and other customer preferences. Battery testing results from MohileMark 2007. -"Requires software and activation to enable theft protection. ""Accessories and Integrated options may vary depending on your notebook configuration. Please consult your reseller or Panasonic representative before purchasing. For more information, call 1.800.662,3537 or visit us on the Web at !Danasonic.comitouQnbook. intel)! Panasonic is constantly enhancing product specifications and accessories. Specifications subject to change without notice. Trademarks are property of their respective owners. 02008 Panasonic tentrin0 Du? ideas for Ode- Corporation of North America. All rights reserved. I I E ss30mk2 02/08 Panasonic recommends Windows Vista® Business. toughbook 74 High Performance, Durable and Wireless • Daylight -readable LCD with Touchscreen • Full Magnesium Alloy Case with Handle • Shock -mounted, Removable Hard Drive Drop- and Spill -resistant IM Mobile Broadband -ready Design toughbook 74 High Performance, Durable and Wireless Panasonic recommends Windows Vista® Business. SOFTWARE • Genuine Windows' XP Professional SP2 or Genuine Windows Vista* Business • Setup, Diagnostics, DMI Viewer, Online Reference Manual, Adobe' Reader, Hard Disk Data Erase Utility, Recovery DVD, WinDVD 5, Bs Recorder GOLDS BASIC, B's CUP6 CPU • Intel' Core' 2 Duo Processor T7300 - 4MB L2 cache - Processor speed 2.OGHz - 800MHz FSB STORAGE & MEMORY • 1024MB SDRAM (DDR2) standard, expandable to 4O96MB' • 80GB hard drive (shock -mounted and user -removable) DISPLAY • 13.3" 1024 x 768 p(GA) transmissive, daylight -readable TFf active matrix color LCD with tuchscreen • External video support up to 2048 x 1536 at 16.7 million colors • Intel' GM965 integrated video controller max. 384MB (DVMT) VRAM • Anti -glare, anti -reflective coating • 460 nit LCD brightness AUDIO • Analog Devices AD1884 compliant audio codec • Inter high -definition audio compliant • Integrated stereo speakers • Convenient keyboard volume and mute controls EXPANSION SLOTS • PC card type II x 1 • Secure Digital (SD) card x 1 • ExpressCard/54 x 1 MULTIMEDIA POCKET • Combo Drive (DVD-ROM/CD-R/RW) standard • Accepts optional DVD Super MULTI Drive with Dual Layer Support KEYBOARD & INPUT • 87-key with dedicated Windows' key • Electrostatic touchpad with scrolling support • Touchscreen LCD • Integrated stylus holder INTERFACE • External video Mirti-D-sub 15-pin • Headphones/speaker Mini -jack stereo • Microphone/line In Mini -jack stereo • Mini dock box replicator Dedicated 65-pin • Serial D-sub 9-pin • USB 2.0 (x 2) 4-pin • 10/100/1000 Ethernet RJ-45 • 56K bps Modem RJ-11 WIRELESS • Optional integrated mobile broadband (WWAN) • Inter Wireless WiFi Link 4965AG 802.11a/b/g • Bluetooth' v.2.0 + EDR • Security - Authentication: LEAP, WPA, 802.1 x, EAP-TLS, EAP-FAST, PEAP - Encryption: CKIP, TKIP, 128-bit and 64-bit WEP, Hardware AES • Slide on/off switch POWER SUPPLY • Lithium ion battery pack (I I A V, 78OOmAh) • Battery operation: approx. 8 hours" • Battery charging time: approx, 4.5 hours" • AC Adapter: AC IOOV-240V 50/60Hz, Auto sensing/switching worldwide power supply • Intelligent power measurement for precise battery status reporting • Pop-up on -screen battery status reporting POWER MANAGEMENT • Suspend/Resume Function, Hibernation, Standby, ACPI BIOS SECURITY FEATURES • Password Security: Supervisor, User, Hard Disk Lock • Cable lock slot • Trusted platform module (fPM) security chip v.1.2 • Computrace theft protection agent*" • Fingerprint scanner (option) • SmartCard reader (option) WARRANTY • 3-year limited warranty, parts and labor DIMENSIONS & WEIGHT • 1.7-2.4"(H) x 12.0"(W) x 11.6'(D) • 5.95 lbs. For more information call 1.800.662.3537 or visit us on the Web at panasrcnic.com,/toughbook. Panasonic is constantly enhancing product specifications and accessories. To find the most up-to-date information on the-Ioughbook 74, please visit our welzsite. Specifications subject to change without notice. Trademarks are property of their respective owners. 02007 Panasonic Corporation of North America. All rights reserved. ss74 05/08 ® Daylight -readable LCD with Touchscreen • Full Magnesium Alloy Case with Handle ® Shock -mounted, Removable Hard Drive ® Drop- and Spill -resistant ® Mobile Broadband -ready Design INTEGRATED OPTIONS — Mobile Broadband Solutions - EV-DO Rev. A - HSDPA (available at a future date) • SmartCard reader • Fingerprint scanner ACCESSORIES'* • AC Adapter (3-pin) CF-AA1683AM • Battery Charger CF-VCBTBI W • ToughMate ComUniversal Carrying Case Oarge capacity) COMUNIV-P • ToughMate ComUniversal Jr. Carrying Case COMUNIVJR-P • Mini Dock Box Replicator CF-VEBUO6W • DVD Super MULTI Drive CF-VDM742U • External USB Floppy Drive CF-VFDU03U • Lithium Ion Battery Pack CF-VZSU43AU • Memory Cards - 1 GB CF-WMBA601 G - 2GB CF-WMBA602G • Touchscreen Large Stylus with Tether Hole CF-VNP009U • 13.3" LCD Protector Film CF-VPF05U • Large Venue DLP Projector PT-DW5100U • Mobile LCD Projector PT-LB60U 'Total usable mernory will be less depending upon actual system configuration. -Battery performance features such as charge time and life span can vary according to the conditions under which the computer and battery are used. Battery operation and recharge times vri9 vary based on many factors including screen brightness, applications, features, power management. battery conditioning and other customer preferences. Battery testing results from MobileMark 2005. "'F?eyuires software aid activation to enalie theft protection. —Accessories and Integrated Options may vary depending on your notebook configuration. Please censA your resdler a Panasonic representative before purchasing. r, sounic E:r [ore 2-ideas '°'fnside Denis Law, Mayor February 2, 2009 Rob Schommer Systems Interface Inc 22125 — 17`i'Avenue SE, Suite 111 Bothell, WA 98021-7406 CITY OF RENTON Public Works Department Gregg Zimmerman P.E., Administrator SUBJECT: CITY OF RENTON RADIO REPEATER CONTROL PANEL Dear Rob: You are authorized to construct the new radio repeater control panel per the attached proposal. Please coordinate the review of the panel design and any questions with Chris Roberts at RH2 Engineering, at 425-951-5400, ext. 5358. The panel will be paid under City of Renton Purchase Order #18/0001623. Please include the purchase order number on the invoice and submit it to the City of Renton Utility Systems, Attention Teresa Phelan. If you have any questions, please contact me at 425-430-7206 or mbenoit@rentonwa.gov. Sincerely, Michael A. Benoit Wastewater Utility Project Manager Attachment cc: Mark Miller, RH2 Engineering Chris Roberts, R112 Engineering H:\File Sys\W WP - WasteWater\WWP-22-0042 Sanitary Sewer Telemetry\SII-01.doc\MABtp 1055 South Grady Way - Renton, Washington 98057 ® 1his papa pomains SJ'' b re ycla 1 rnatenal, >0 % post cons irnr r RENTON AHEAD OF THE CURVE. Systems Interface Inc. t 4 (425) 481-1225 T (425)481-2115 F www.systems-interface.com 22125 17th Avenue SE - Suite 111 Bothell, WA 98021-7406 USA To: Chris Roberts Company: RH2 Engineering Re: City of Renton Radio Repeater Control Panel From: Rob Schommer Date: 2/2/2009 Hi Chris, QS09AO23 Thank you for the opportunity to provide a quotation to manufacture a Radio Repeater Control Panel for the Hazen Reservoir Site. This panel would be very similar to the telemetry panels Systems Interface has previously manufactured for the City. Our proposed scope of supply includes: 1) Engineering Services to revise the RH2 Panel design for this particular application and submit for review. 2) Manufacture one Radio Repeater Telemetry and Control Panel with the following features: • 24"x24"x8" Enclosure; Nema 4 rated, painted steel, with Key lock Handle • Custom White Paint on exterior of panel • 120 VAC Power Distribution with Circuit Breakers • 500 VA UPS (APC BE5000) for power isolation • TVSS surge protection and convenience GFCI receptacle (Tycor Aegis style) • 100 Watt Anti -condensate, forced -air, panel heater with thermostat. • Rugid 9 RTU with LCD Interface, two Modem cards, Battery Charger, and Inputs/Outputs as required. • Installation and wiring of Dataradio Radio Modem (provided by the Owner and drop -shipped to S11). • Radio cables and lightning protector (per City Standards). • 15 VDC Power Supply with Circuit Breaker power distribution (for Radio) • AC and DC Power Fail Monitoring Relays. • One 12VDC, 12 AmpHour Gel -Cell Battery (for battery backup) • Terminal Blocks, Wire Duct, Engraving, and misc. panel components. • UL 508 certification Our exclusions are: • The JSLM Analog Radio (provided by the City) • Spare Parts • On -site Testing, Calibration, Commissioning, or Training services (optionally available) • Field Instruments, Field Installation, Field Wiring, or Field Terminations • Bonding costs or any related taxes. TotalPrice............................................................................................................... $4,895 Proposed Terms: 100% upon delivery to the City, Net 30, Freight included. Estimated Delivery: Two to three weeks from Receipt of Purchase Order. Please call me with any questions or concerns. Sincerely, Systems Interface Inc. Robert Schommer, P.E. Vice President 1of1 Systems Interface Inc. (425) 481-1225 T (425) 481-2115 F www.systems-interface.com 22125 ffh Avenue SE - Suite 111 Bothell, WA 98021-7406 USA To: Chris Roberts Company: RH2 Engineering Re: City of Renton Radio Repeater Control Panel Date: 2/2/2009 From: Rob Schommer Pages: 1 Hi Chris, QS09AO23 Thank you for the opportunity to provide a quotation to manufacture a Radio Repeater Control Panel for the Hazen Reservoir Site. This panel would be very similar to the telemetry panels Systems Interface has previously manufactured for the City. Our proposed scope of supply includes: 1) Engineering Services to revise the RH2 Panel design for this particular application and submit for review. 2) Manufacture one Radio Repeater Telemetry and Control Panel with the following features: • 24"x24"x8" Enclosure; Nema 4 rated, painted steel, with Key lock Handle • Custom White Paint on exterior of panel • 120 VAC Power Distribution with Circuit Breakers • 500 VA UPS (APC BE5000) for power isolation • TVSS surge protection and convenience GFCI receptacle (Tycor Aegis style) • 100 Watt Anti -condensate, forced -air, panel heater with thermostat. • Rugid 9 RTU with LCD Interface, two Modem cards, Battery Charger, and Inputs/Outputs as required. • Installation and wiring of Dataradio Radio Modem (provided by the Owner and drop -shipped to SII). • Radio cables and lightning protector (per City Standards). • 15 VDC Power Supply with Circuit Breaker power distribution (for Radio) • AC and DC Power Fail Monitoring Relays. • One 12VDC, 12 AmpHour Gel -Cell Battery (for battery backup) • Terminal Blocks, Wire Duct, Engraving, and misc. panel components. • UL 508 certification Our exclusions are: • The JSLM Analog Radio (provided by the City) • Spare Parts 17 • On -site Testing, Calibration, Commissioning, or Training services (optionally available) r , ,l • Field Instruments, Field Installation, Field Wiring, or Field Terminations l • Bonding costs or any related taxes. At d TotalPrice............................................................................................................... $4,895 Proposed Terms: 100% upon delivery to the City, Net 30, Freight included. Estimated Delivery: Two to three weeks from Receipt of Purchase Order. Please call me with any questions or concerns. Sincerely, Systems Interface Inc. Robert Schommer, P.E. Vice President � Ps ti f �s l ?` ,P 1 of I \��ti N� 0'A �vv 4 Michael A Benoit From: Mark Miller [mmiller@RH2.com] Sent: January 30, 2009 11:01 AM To: Michael A Benoit Subject: FW: City of Renton Radio Repeater Panel Cost Estimate Attachments: rpt-d-elecOl .pdf FYI From: Chris Roberts Sent: Friday, January 30, 2009 10:53 AM To: Schommer, Rob H. Cc: Mark Miller; James Swanson Subject: City of Renton Radio Repeater Panel Cost Estimate Hi Rob, Can, you please provide us with a quote for the construction of a radio repeater panel for the City of Renton. Attached are plans for the proposed panel. Equipment with model numbers specifically not called out on the plans shall be provided based on previous City of Renton Wastewater panels that Systems Interface has constructed. Please include in your quote submittals to be reviewed by RH2 and also inspection and shop testing of the panel at your facility prior to shipment. Please also let us know approximately how long it will take to prepare the cost estimate. Please address and send the quote to Mike Benoit with the City of Renton (mbenoit@rentonwa.gov) and send a copy to myself as well. Please contact me with any questions or concerns. Thank you, Chris Roberts, P.E. Project Engineer Phone: (425) 951-5358 Fax: (425) 951-5359 croberts@rh2.com RH2 Engineering 12100 NE 195th St. Suite 100 Bothell, WA 98011 www.rh2.com INCOMING POWER CBl 120 VAC, 15 AMP I- L1 5 AMP 120 VAC N 11 N GIRD GIRD N 1 UPS UPS - 120VAC, 50OVA, 3 UPS eI AND 3 SURGE OUTLETS, UL GN) RATED APO MODEL BE5000 OR I , I EQUAL H (120 CH1 C83 C04 12P CR OPT C05 CB6 n CR DPF 12P L1 `- N LINE SURGE PROTECTOR L1 GMD N N 120 VAC AC POWER FAIL OR RP PF CR F PANEL GA DATER WITH THERMOSTAT. POWER SUPPLY 120 VAC TO 12 VDC 12N G9Q.:s OC POWER FAIL -0 TCR ^DPF RUG 9 PROPOSED DATA RAD10, MODEL JSLM2 ANALOG RADIO PROVIDED BY CITY. INSTALLED BY PANEL SHOP IN PROPOSED PANEL ANALOG RADIO 450-470 MHz, 25KHz BATTERY 12 VDC a [L w Qin w cc t: a O L)U w w U w L) w U ILWO V O O 2 L) G? a a a IL 2 g CL = IL to U1 0 rn O L) Z ❑ O 00 O J w - 0 O Do 00 O 0 00 O O PROPOSED DATA RADIO, MODEL JSW2 ANALOG RADIO PROVIDED PROPOSED CUSTOM COMMUNICATION BY CITY. INSTALLED BY PANEL CABLE. SEE COMMUNICATION CABLE SHOP IN PROPOSED PANEL CONNECTION DIAGRAM THIS SHEET. ANALOG RADIO LINE SURGE 450-470 MHz-25KHz PROTECTION UNIT 15 PIN D CONNECTION ENGRAVED RIGID LAMINATED PLASTIC LABEL WITH ADHESIVE BACKING AND TWO BRASS SCREWS (ONE EACH SIDE). COLOR SHALL BE BLACK WITH WHITE 12N LETTERING. LETTER HEIGHT SHALL BE 1/2-. LOOP 24' CHARGER MMMMUM BT+ GND 24+ TO DIGITAL INPUTS 24- TO DIGITAL INPUTS REPEATER PANEL POWER SUPPLY DIAGRAM — NOT TO SCALE NOT TO SCATS 24' MAXIMUM — — — — — — — , , — — — — — — — • HAZER R✓EPEATEA PARE I I I I I I KEY LOCK HANDLE I I I WARNING LABEL REPEATER PANEL ENCLOSURE NOT TO SCALE RUG 9, PLC OPERATOR INTERFACE ON FRONT OF CARD CAGE DISPLAY CABLE RUG 9, RUCD COMPUTER J PROPOSED OINI-DIRECTIONAL _ ANTENNA PROVIDED BY OTHERS. PROPOSED ANTENNA CABLE PROVIDED BY OTHERS. 12• DEEP, NEMA 4X STAINLESS STEEL ENCLOSURE PROPOSED POLYPHASER LINE SURGE PROTECTION UNIT MOUNTED TO SIDE OF PANEL WITH ANTENNA CONNECTION LOCATED ON PANEL EXTERIOR AND RADIO CONNECTION LOCATED IN PANEL INTERIOR. RADIO COMMUNICATIONS TO REMOTE SITES AND MASTER TELEMETRY UNIT TELEMETRY PANEL NOTES 1. THIS TELEMETRY BLOCK DIAGRAM IS SCHEMATIC N NATURE AND DOES NOT INCLUDE ALL ACCESSORIES AND APPURTENANCES NEEDED FOR A COMPLETE TELEMETRY SYSTEM. THESE DIAGRAMS ARE INTENDED TO ASSIST THE PANEL SHOP BY IDENTIFYING THE REQUIRED 1/0 FOR TH#S FACIUTY AND TO GIVE GENERAL GUIDELINES FOR THE TELEMETRY PANEL THE PANEL SHOP IS RESPONSIBLE FOR PROVIDING A COMPLETE TELEMETRY PANEL PACKAGE TO MEET THE REQUIREMENTS OF THE BID DOCUMENTS AND TO RESULT N A COMPLETELY OPERATIONAL SYSTEM THAT MEETS THE CITY OF RENTON STANDARDS. 2. THE FOLLOWING EQUIPMENT SHALL BE INCLUDED IN THE TELEMETRY ENCLOSURE: - ENCLOSURE HEATER - IRS (TO PROTECT 120 VOLT EQUIPMENT) - 24 UDC SURGE PROTECTION - OPERATOR INTERFACE - RADIO (MATCH TYPE AND FREQUENCY USED BY CITY OF RENTON) - BATTERY CHARGER AND BATTERY BACKUP - AC AND DC POWER FAIL INDICATION COMMUNICATION & POWER COLOR LEGEND F120 VOLT EQUIPMENT LOW VOLTAGE EQUIPMENT COMMUNICATIONS EQUIPMENT LLLL RUGID CPU AND 1\0 EQUIPMENT s7cFaa 01/30A9 YTL O t yol o+°♦ 2� so SxN8a 01/30A9 � a ma (+Amet).-4 cn MD1M232 Z a Q KEWOHzog d N CABLE, TYPICAL ANALOG RADIO W Z936* a 1 11��11 p: W RX-+1I� ❑ 7 O KE o 15 15 PIN CONNECTOR O W TX O Tx ❑ a BAn+ IRuao ® BATT- r�! W ~� V Z COMMUNICATIONS CABLE CONNECTION DIAGRAM N NO SCALE Q 2 F1 CR- CR-1 gl REPEATER PANEL DIGITAL INPUTS E N G I N R S PLANN R 5 .I EN'7I ST'S lw W167 ENGINEERING. INC. ^WDo�067 cr am 72C SM2 ZLAJNG+ oPPtce 360676 0036 �5' W"' Fate 4— mOTIliL OA10E 42595, 5400 12100 NE '950 Snot S.Ne '00 EAR MTMATGK[ OUP= 509 8N 2900 300 S— Steel. Su to 5 PORT ORCHARD 0" 360 676 7960 600 1.,— S—I. SCALE: SHOWN 0 1 2' DRAWING IS NOT TO SCALE IF BAR IS NOT 2' LONG w, 1 oR •n —DY E01 Eta MUM 0�2 Jm 30. 2009 RI �. 1 m R>; 107-112 t �ou1a RPT-D-ELEC0I.DWG Kathy Keolker, Mayor October 31, 2007 Mark Miller RH2 Engineering Inc 300 Simon Street SE, Suite 5 East Wenatchee, WA 98802 CITY OF RENTON Planning/Building/PublicWorks Department Gregg Zimmerman P.E., Administrator SUBJECT: MAINTENANCE OF TELEMETRY SYSTEM i�b2iC Dear Mr-MMer: As you may have heard, we had another incident where RH2's actions in updating our telemetry system have violated the City's Electronic Data Security Policy #250-16. We have met with our Information Services Department (IS) and have agreed on a new procedure for the maintenance of the telemetry system. Purchasing and repair of hardware will be coordinated through IS. At this time, the Utilities and our consultant remain responsible for the maintenance and operation of the telemetry. We will expect RH2 to continue to coordinate with the Maintenance Supervisors for the in-house work and complete the work logs to document what has been done and what may need to be done. An information copy of the work logs should be e-mailed to J.D. Wilson and me so we are aware of the system's status. Maintenance of the system that necessitates an Internet connection shall be coordinated through IS. Please contact the IS Help Desk at 425430-6870 or ISHelp(caci.renton.wa.us, at least one day before access is needed. At that time or with a follow-up call, they will authorize and confirm access. IS will then activate a port for your use. When finished with the work, please contact the help desk and let them know they may disable the port. If they do not hear back, they will automatically disable the port. Most likely, the port will be automatically disabled when staff leaves for the day around 5:00 p.m., or maybe as late as 6:00 p.m. Unless it is system critical, do not plan on having access after that time. If it is critical, discuss the need with IS so they may make arrangements for someone to stay to manage the system. If there is an after hours situation that cannot wait until the next working day, please contact IS at 206-300-0571 (on -call cell phone). If you have any questions, please let me know. Sincerely, Michael A Benoit Wastewater Utility Engineer cc: Lys Hornsby, Utility Systems Director George McBride, Information Services Contractor J.D. Wilson, Water Utility GIS/Engineer H:\File Sys\WWP - WasteWater\WWP-03-0000 Correspondence - Wastewater\MIKEBVU12 Telemetry0l.doc\M p 1055 South Grady Way - Renton, Washington 98057 E N T O N AHEAD OF THE CURVE This papercontains 50 % recycled material. 30 % post consumer Michael Benoit - SCADA Network Page 1 ; From: "Lee Tumbleson" <Iumbleson@RH2.com> To: <jwilson@ci.renton.wa.us>, "Michael Benoit' <Mbenoit@ci.renton.wa.us>, <rsled@ci.renton.wa.us>, <cscottie@ci.renton.wa.us> Date: 09/24/2007 10:41:45 AM Subject: SCADA Network It is our understanding that City staff are going to meet to discuss the network connectivity of the SCADA system. To assist you with this, the following is a brief summary of the chronology regarding the SCADA internet access. In September of 2004, the IS Department provided a limited -connectivity port to allow authorized personnel at City Hall to access the InSQL Server in the Water/Wastewater control system. The IS Department and RH2 attempted, until approximately February of 2005, to gain access to the internet from this connection. At that time, we abandoned the effort. The system was running and there was no immediate need to patch Windows. Hence, internet access was not necessary. We are currently working to upgrade the computers with new versions of software that require the operating system to be patched. Due to our unsuccessful efforts with IS to gain access to the internet in 2004/05, we took the initiative to temporarily gain access to the internet using another connection. We have attached the network diagrams. In both diagrams, the InSQL server has two network cards, attached to two different networks. You will notice, in the diagram, that the SCADA system was isolated by a firewall. From what we have been told, on September 14, the City IS staff disconnected both Ethernet cables that connect the SCADA LAN to the City. It also appears that IS staff may have changed configurations on the InSQL Server when they unplugged the network cable; the network adapter was disabled in Windows. I re -enabled the network adapter on September 18. The City IS staff restored the 172... connection on September 18, also. Currently, the system has been restored to the 2004 configuration. To enable proper maintenance of the SCADA system, we will periodically require internet access. Please advise as to the proper method by which we can gain internet access. L. Lee Tumbleson, P.E. Control Systems Project Manager Mic Benoit - SCADA Network Page 2 425.951.5330 425.951.5401 fax RH2 Engineering, Inc. 12100 NE 195th St Suite 100 Bothell, WA 98011 800.720.8052 This message contains confidential information and is intended only for the addressed recipients. If you are not the addressed recipient you should not disseminate, distribute or copy this e-mail. Any views or opinions presented in this email are those of the author and may not represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: "Mark Miller" <mmiller@RH2.com>, "Tony V. Pardi" <tpardi@RH2.com> 10... (DHCP) Druce September 2004 August 2007 QL Server ACP Host .168.100.X I Switch Water2 10... (DHCP) 172.25.1.64 IUI IIII II Linksys 5-Port Switch InSQL Server DHCP 10..... Linksys Router 4-Port FO-1 DHCP Host Druce 192.168.100.X DHCP RRQ�� ApA AA�R� Linksys 8-Port Switch Waste2 ham= I Wastel -. I Waterl I = . I Water2 The Dell Online Store: Build Your System http://configure.us.dell.conVdeiIstore/print_summary_detaiIs_popup.aspx... 0 'M Print Summary PowerEdge 860 rem $3,642 mwx $2,730 1 _ease frorr $731rno. (48 pmts) Estimate Payments ; Apply Dis;ro :r1t = e';aiis hf -.:!"Y:eluTunary Ship Date: 5/31/20072 My Selections All Options • PowerEdge 860 Print this paqe Close Afford the latest technology with a 0%24 Month Leaset3 'Offer available for best -qualified business customers. More Details Date 5/22/2007 11:19:48 AM Central Standard Time Catalog Number 4 Retail 04 Catalog Product Code SKU Id Number / Description PowerEdge 860: Dual Core Intel@ Pentium@D 935, 86D32 [222-7792] 1 3.2GHz, 2x2MB Cache, 800MHz FSB Memory: 1GB DDR2,667MHz, ixiGB Dual 1G1D6D [311-6323] 3 Ranked DIMMs Operating System: Windows Server@ 2003 R2, WSR2S [420-5796] 11 Standard Edition, Includes 5 CALs O/S Partition: Maximum Partition Size for MS MAXPART [420-4018] 37 Windows Factory Installed Operating Systems Primary Hard Drive Controller: SAS 51R internal RAID adapter, SAS51R [341-3874] 9 PCI-Express Hard Drive Configuration: Add -in SAS5iR (SATA/SAS ASR1 [341-3870] 27 Controller) which supports 2 Hard Drives - RAID 1 Primary Hard Drive: 300GB, SAS, 3.5-inch, 10K RPM 30OA10 [341-4201) 8 Hard Drive 2nd Hard Drive: 300GB, SAS, 3.5-inch, 10K RPM 300A10 [341-4201] 23 Hard Drive I of 3 5/22/2007 9:19 AM The Dell Online Store: Build Your System http://configure. us.dell.conVdelistore/pri nt_summary_detai ls_popup.aspx... Riser Card: Riser with 2 Slots: 1 PCI Express x8 slot and 1 PCI Express x4 slot Rack Rail Options: 2-Post Rails for Non -DELL Rack, center or flush mount Bezel: Bezel Network Adapter: On -Board Dual Gigabit Network Adapter, No TOE TCP/IP Offload Engine Enablement: Broadcom0 Dual Port TCP/IP Offload Engine Not Enabled RSRPCIE [320-4959) 2POST [310-67121 BEZEL [313-4428] OBNIC [430-20081 NTOEKEY [430-17651 Documentation: No Hard Copy Documentation, EDOCS E-Docs Only and OpenManage CD Kit Hardware Support Services: 3Yr BASIC SUPPORT: 5x10 U30S HW-Only, 5x10 NBD Onsite Installation Support Services: NOINST No Installation Assessment CD/DVD Drive: 24X IDE CD-RW/DVD ROM Drive CDRWDVD for PowerEdge Servers, All OS [310-81801 28 17 13 21 [960-5302] [970-0940] [985-1267][985-1317][985-13781 29 [900-99971 (313-4711 ] 32 16 Print Pricing, specifications, availability and terms of offers may change without notice, are not transferable and are valid only for new purchases from Dell Small Business for delivery in the 50 United States. Taxes, fees, shipping, handling and any applicable restocking charges extra, vary, and are not subject to discount. The Small Business site and offers contained herein valid only for end users and not for resellers and/or online auctions. Dell cannot be responsible for pricing or other errors, omissions, or consequences of misuse of site and its functions and reserves the right to cancel orders arising from such errors. Offers not necessarily combinable. Discounts cannot be retroactively applied. Orders subject to cancellation by Dell. Software & Accessories and Printers, Displays & Electronics offers do not apply to Recommended Solutions systems in the online system configuration pages (including PowerConnect switches); you must purchase eligible items through the separate Software & Accessories and Printers, Displays & Electronics online stores. Limit 5 systems and 5 discounted or promotional products per customer. In case of customers leasing under this promotion, please note that items leased will be subject to applicable end of lease options or requirements. All sales are subject to Dell's Terms and Conditions of Sale located at 'ratpJ%vn w.del l.ccm%terms unless you have a separate agreement with Dell. ' Monthly payment based on 48-month Fair Market Value ("FMV") QuickLease and does not include taxes, fees, shipping and handling charges. Your monthly payment may vary, depending on your creditworthiness. QuickLease arranged by Dell Financial Services L.P. ("DFS"), an independent entity, to qualified Small Business customers. Minimum transaction size of $500 required. At the end of the FMV QuickLease, you can: purchase the equipment for the then FMV, renew the lease or return the equipment to DFS. Please contact your DFS representative for further details. All terms subject to credit approval and availability, and are subject to change without notice. 2 The Preliminary Ship Date represents the estimated time it takes to process your order and custom build your computer based on approved credit card purchase. The Preliminary Ship Date is not intended to provide you with an actual estimated ship date. Your estimated ship date may vary based upon the payment method you choose and other factors. You will receive your Estimated Ship Date in your e-mail confirmation. Customers using E-Check as their method of payment should add 3 days to their Preliminary Ship Date. 3 0% 24 Month Fair Market Value Lease arranged by Dell Financial Services L.P. ("DFS"), an independent entity, to well -qualified Small Business customers. All terms are subject to credit approval and availability. 0 % 24-month Fair Market Value (FMV) lease offer only applicable for new hardware. 0 % Implicit lease rate, assuming lessee does not exercise a fair market value purchase option and timely returns the leased equipment to lessor at the end of the lease term, and disregarding any charges other than 24 rent payments (such as taxes, fees, shipping and handling charges). Minimum transaction size of $500 required. Terms are subject to change without notice. Not valid on past orders or leases. a, .ra 1999-2007 Dell Inc. Rc ,.:! About = e1 ;loncic ens o` Sa:; _ T:° 'vnresalved s a..: P ;. P ;:icy vor;tac* Us I Site Man. I eedha*, 2 of 3 5/22/2007 9:19 AM The Dell Online Store: Build Your System http://configure.us.dell.con/dellstore/print_summary_details_popup.aspx... sn CFG5 3 of 1 5/22/? i07 9: 1 y AM I� .�.ti� \Sb dth� SC2�Av �S-23z c.A3►� �"�''r`r ����� �1,.�_ 8 'P�y L-�•r�.ti�+.�-c_ �s� r.� oo•�, SC�.��b�� r�C- ti \� � `��:aC CAB�•i s �� SPL�•7��2 'Tt, W a.5cc:r '3c.T►►- ra �.J!rw 1 LZA'T MA- r Michael Benoit - RE: HMI Upgrade Hardware Page 1 From: "Lee Tumbleson" <Itumbleson@RH2.com> To: "Lee Tumbleson" <Itumbleson@RH2.com>, "J.D. Wilson" <Jwilson@ci.renton.wa.us>, "Michael Benoit" <Mbenoit@ci.renton.wa.us> Date: 05/22/2007 9:19:17 AM Subject: RE: HMI Upgrade Hardware Z 5 ! Q Here is an update list of equipment: r � r a) Part number R9MDM ($185), CBL232 ($15), both from RUGID, http://www.trianglecables.com/25db9mf.html <http://www.trianglecables.com/25db9mf.html> ($10) b) http://www.trianglecables.com/2waydb9mansw.htmi <http://www.trianglecables.com/2waydb9mansw.html> ($9),/ `J http://www.trianglecables.com/cbl58.html <http://www.trianglecables.com/cbl58.html> ($4x2) As you may recall, we will be connecting a cable directly from the Bristol to the server and directly from the Bristol to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. c) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 j <http://www.newegg.com/Product/Product.asp?Item=N82E16825104137> ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. d) Spare hard drive ($289 - the price of this has likely changed, but the part number is still valid - 340-9377), see attached for server spec ($2,730) e) Rack/cabinet research is ongoing; we wanted to present the rest of the equipment while we finish that research. f) http://www.trianglecables.com/2waydb9mansw.html <http://www.trianglecables.com/2waydb9mansw.html> ($9),--' http://www.trianglecables.com/cbl 58.html <http://www.trianglecables.com/cbl58.html> ($4x2) ✓✓ As you may recall, we will be connecting a cable directly from the RUGID to the server and directly from the RUGID to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. g) http:/ .neweg .com roduct/Pro ?Item=N82E1 5104137'�� <hfip://w*.ne gg.c /Produ Produ . asp? Item 82E16 5104137> ($35x2), standardvOohe cables a fitters should be ased to connect.both modems to the wall jack simultaneously. Lee k-t 4V Michael Benoit - RE: HMI Upgrade Hardware Page 2 From: Lee Tumbleson Sent: Thursday, February 15, 2007 8:26 AM To: J.D. Wilson; Michael Benoit Cc: James Swanson; Mark Miller Subject: RE: HMI Upgrade Hardware $289 for the spare hard drive. This is a quote for RH2; the price may vary slightly when your IS Department requests a similar quote. Lee From: Lee Tumbleson Sent: Wednesday, February 14, 2007 4:56 PM To: 'J.D. Wilson; 'Michael Benoit' Cc: James Swanson; Mark Miller Subject: RE: HMI Upgrade Hardware The RUGID will also need a COM cable and an extension to the PC. I updated item a) below. Lee From: Lee Tumbleson Sent: Wednesday, February 14, 2007 4:52 PM To:'J.D. Wilson; Michael Benoit Cc: James Swanson; Mark Miller Subject: HMI Upgrade Hardware Per the Scope of Work, Task 1, we submit for review the following: a) Provide City with specifications of RUGID Communications Board to purchase b) Specify Serial Communications switch box and cables for Water Bristol communications. c) Specify internal modems for Water SCADAlarm and cables and splitters for phone lines. d) Specify Spare Server for InSQL and RAID drive, these will sit on a shelf until needed. it Michael Benoit - RE: HMI Upgrade Hardware Page 3 e) Specify rack/cabinet equipment f) Specify Serial Communications switch box and cables for Wastewater RUGID communications. g) Specify internal modems for Wastewater SCADAlarm and cables and splitters for phone lines. h) Provide a report outlining equipment and labor for a fully hot backup for all system components. h) Part number R9MDM ($185), CBL232 ($15), both from RUGID, http://www.trianglecables.com/25db9mf.html ($10) i) http://www.trianglecables.com/2waydb9mansw.htmi ($9), http://www.trianglecables.com/cbl58.html ($4x2) As you may recall, we will be connecting a cable directly from the Bristol to the server and directly from the Bristol to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. j) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. k) Spare hard drive quote is coming (-$200?), see attached for server spec ($2,944) 1) Rack/cabinet research is ongoing; we wanted to present the rest of the equipment while we finish that research. m) http://www.trianglecab►es.com/2waydb9mansw.html ($9), http://www.trianglecables.com/cbl58.html ($4x2) As you may recall, we will be connecting a cable directly from the RUGID to the server and directly from the RUGID to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. n) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. o) Report is not complete L. Lee Tumbleson, P.E. Control Systems Project Manager 425.951.5330 425.951.5331 fax i Michael Benoit - RE: HMI Upgrade Hardware Page 4 RH2 Engineering, Inc. 12100 NE 195th St Suite 100 Bothell, WA 98011 800.720.8052 This message contains confidential information and is intended only for the addressed recipients. If you are not the addressed recipient you should not disseminate, distribute or copy this e-mail. Any views or opinions presented in this email are those of the author and may not represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: "James Swanson" <jswanson@RH2.com>, "Mark Miller" <mmiller@RH2.com> sd(-) ►ro" L�� HP Channel Services: Network Pagel of 2 t� http://h30l25.www3.hp.com/csn/salesmktg/elfpack/elf all_certificates.asp?code=ELEM:4:-USA&1... 6/7/2007 HP Channel Services Network , <1 .� f u, G 7 Page 2 of 2 Registration Information Product Serial Product product Description No. Number USE723N2VH 399524-B21 HP DL360R05 4M CTO Chassis HP Care Pack Serial Number GOOSUS013526 M Page 2 of 2 http://h30125.www3.hp.com/csn/salesmktg/elfpack/elf all certificates. asp?code=ELEM:4:-USA&1... 6/7/2007 _.f j Michael Benoit - Wastewater/Storewater SCADA System Review Page 1 From: "James Swanson" <jswanson@RH2.com> To: "Michael Benoit" <Mbenoit@ci.renton.wa.us> Date: 04/27/2007 2:08:17 PM Subject: Wastewater/Storewater SCADA System Review Mike, I have attached the Wastewater SCADA review documents to this email for your review. I have substantially rewritten and simplified this report based on new information that I learned over the last few months. The decommisioning by the City of a number of lift stations in the early part of 2008 will add 3-5 operational years to your current system by supplying it with spare control panels and spare parts. Other than a new repeater at the Hazen reservoir, there is no pressing need to start a second radio network unless the City decides to be pro -active by phasing out the Rugid equipment in a shorter period of time. Please refer to the communications section for most of the main issues regarding the SCADA system. I have also included a block diagram of your existing system and an upgraded version for your review. am also currently working with a number of other City's and Districts on identifying how they will transition from the Rugid controller platform to an open architecture platform in the future. The concept behind this is to allow any name brand controller to be implemented in much the same way modern computer networks are designed. Let me know if you have any questions or if you need more detail on any issue brought up in this report. James Swanson RH2 Engineering I SCADA Manager www.rh2.com I jswanson@rh2.com (main) 800.720.8052 x 5386 (cell) 206.794.6615 (direct) 425.951.5386 (fax) 425.951.5387 This message contains confidential information and is intended only for the addressed recipients. If you are not the addressed recipient you should not disseminate, distribute or copy this e-mail. Any views or opinions presented in this email are those of the author and may not represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: "Mark Miller" <mmiller@RH2.com> Draft Report Wastewater/Stormwater SCADA System Future Requirements Review and Recommendations Prepared for City of Renton April 2007 Table of Contents 1. Monitoring and Control Instrumentation ................. Monitoring and Control Instrumentation Conclusions 2. Facility Control Equipment ..................................... Facility Control Equipment Conclusions ..................... 3. Communications Network ....................................... Weak Signals in the Highlands .................................... Radio License Refanning............................................ Proprietary Protocol ..................................................... Current Radio Traffic .................................................. Communications Conclusions ..................................... 4. City Shops Backend HMI system ............................ HMI System Conclusions ............................................ ..............................................3 ..............................................4 ..............................................4 ..............................................4 ..............................................5 ..............................................5 .............................................. 5 ..............................................6 ..............................................6 ..............................................6 ..............................................7 ..............................................7 Overview The purpose of this memorandum is to review the city's wastewater/stormwater SCADA system and recommend future requirements. These recommendations will be based on specific criteria that will allow the city to maintain and improve the existing SCADA system in a cost effective process. The current WW/SW SCADA system consists of 4 fundamental areas: 1. Monitoring and Control Instrumentation 2. Facility Control Equipment 3. Communications 4. City Shops Backend HMI system When discussing each area of the existing SCADA system, the following items will be identified to help set priorities for future improvements. 1. Age of asset/Estimated life of asset 2. Current and future supportability of asset 3. Current or obsolete technology 1. Monitoring and Control Instrumentation The current monitoring equipment used at the city's WW/SW pumping stations consists of the following: • Level — Level pressure transducers, high/low/emergency run float switches. • Flow — Calculated based on level at older facilities. Siemens Mag flow meters at the newer facilities. • Flood — Flood switches. • Smoke — Smoke alarms. • Check Valves — Limit Switches. • Pump Status — Run, Overload, Overtemp, Seal Failures from motor control center units. • Intrusion — Intrusion switches and intrusion override locks. All facilities use liquid level sensors for control purposes with backup float switches in case of a level sensor or PLC controller failure. These instruments require regular cleaning maintenance but have shown themselves to be fairly robust compared to other level sensing technologies such as bubbler systems. The current level sensors are relatively easily to replace with dozens of different products available for many years in the future. All new facilities that have been built in the last 5 years have included Magnetic Flow Meters on the effluent force main for increasing the accuracy of the influent and effluent flow rates. Very little maintenance is required for these instruments other than to occasionally check on their flow rates to make sure they are within their normal operating range. All discrete (switch type) instruments such as pump/motor status, check valve limit switches, flood switches, smoke alarms and intrusion switches have all worked very well and should have long life spans with easy replacements in case of failure. Monitoring and Control Instrumentation Conclusions The main limitation to the existing instrumentation is accurate flow monitoring from facilities that use the Rugid 6 PLC controllers that were installed in the early 1990's. The influent and effluent flows at these facilities are calculated based on level changes during pumping and non -pumping control periods. Unfortunately, these flow calculations fall apart during peak flows when the pumps may run for long periods of time due to heavy influent. Although this information is not critical from an operations point of view, this type of information is sometimes essential for issues such as calibrating flow modeling or helping to identify system I/I. If the need arises, these sites can easily be retrofitted for effluent Magnetic Flow Meters. Facilities with effluent flow meters and wet well level sensors can also derive inflow rates during pump runs. 2. Facility Control Equipment The current facility control equipment is made up of a primary control PLC with backup relay control in case of PLC or level sensor failure. The primary PLC technology is based on the Rugid line of controllers. These intelligent controllers are made in Olympia Washington by Rugid Computer Inc. The original controllers installed in the early 1990's have consisted of Rugid 6 PLC's. This line of controllers has been phased out over the last 5 years and replaced by the Rugid 9 PLC. All of the city's remote PLC controllers handle the following purposes: 1. Event and alarm monitoring. 2. Instrument monitoring and totalizing of flows, pump starts and runtimes. 3. Pump control based on wet well levels. 4. Radio communications of collected data back to the City Shops. Facility Control Equipment Conclusions The City is currently reliant on the Rugid Computer series of controllers at all of the wastewater lift stations. The vast majority of these controllers are the obsolete Rugid 6 units although the City has started using the new Rugid 9 controllers over the last 5 years. The reasons the City has standardized on these controllers are mainly due to the type of radio communications protocol that these devices use. Because it is proprietary to the Rugid line of controllers, it is difficult to introduce new brands of controllers without creating a new radio network. The Rugid Computer company, however, is a small company out of Olympia, Washington and its future is unclear over the next 10-20 years. At some point, other brands of controllers should be introduced into the wastewater control system to help diversify the system in case Rugid goes out of business. In the meantime, new facilities can continue to use the Rugid 9 controllers because they are also capable of communicating using open protocols like MODBUS. This will allow them to be used in any future wireless network setup alongside other brands of controllers. Also, due to a number of lift stations that will be decommissioned in 2008, their will be extra controllers that can be used at new sites or integrated into existing Rugid 6 facilities. The Rugid 6 controllers that are salvaged from those sites can then be used as spare parts for the remaining Rugid 6 stations. This situation alone has probably added another 3-5 years before the City should start introducing new control brands into the wastewater lift station system. 3. Communications Network The existing communications network for the WW/SW SCADA system consists of a master controller at the city shops polling the remote facilities over a 450MHz radio network. This polling process that the master controller uses is a round robin process that polls all of the facilities over a period of about 2 % minutes and then starts over again. Some of the remote sites can communicate directly with the master controller and some of the sites use a repeater site as a way of direction communications back to the city shops through difficult topology (Diagram 1). A simplified topology of Renton consists of the low laying areas close to Lake Washington heading down 1671" to Auburn and a highlands area to the north and south of Maple Valley. When the original SCADA system was installed in the early 1990's, a repeater site was setup at on the West Hill reservoir to handle communications from the low lying areas near the lake back to the city shops that was located in the highlands area north of Maple Valley. Weak Signals in the Highlands This repeater site worked reasonably well for the original facilities but as new sites where added to the east in the Highlands, it has became more difficult to get communications to these areas. Many of the current remote facilities in the eastern highlands areas are using other remote facilities as repeaters to direct communications back to the city shops. Radio License Refarming The current radio technology is based on the RNET radios from the 1980's that use 450MHz Radios over a 25KHz bandwidth. During the 1990's the FCC started to cut the bandwidth allowed on these licenses from 25KHz to 12.5KHz and finally down to 6.25KHz. Because of capital costs in replacing radio systems and the inability of some radios in handling 6.25KHz due to topology and other environmental issues, the FCC has put off enforcing this regulation until 2013. Proprietary Protocol The Rugid units use a proprietary communications protocol standard with low overhead that allows up to three facilities to act as routers to reach any remote facility. This protocol is not available on any other controller brand. As mentioned in the facility control equipment section, the ability to use other brands of controllers is limited by this protocol. Open protocols such as MODBUS allow any brand of controller to be implemented on a radio network. This would require a second radio network to be setup as dual protocols cannot be easily implemented on one radio frequency. Current Radio Traffic The current radio network is running at about 2-3 minutes to complete one sweep of all of the remote wastewater facilities. With the decommissioning of a number of lift stations in 2008 and a possible second radio network in the next 5-10 years, this polling rate should only improve. Communications Conclusions • The most critical of the communications issues is the lack radio paths in the highlands area due to the only repeater existing to the far west of the City. This should be resolved with the new Hazen Reservoir repeater in 2008. This repeater will have a broad view of most of the northern highlands area of Renton and may even be able to reach facilities on the south side of Maple Valley. In the meantime, a number of radio changes have been made during the winter of 2007 to keep communications running until the repeater is completed. • The FCC frequency refarming issue may become a issue in the next 5 years. This issue this should be monitored carefully to identify how the FCC will proceed. It should be mentioned that the FCC has already moved this date forward twice in the last 10 years. The existing system will probably have some performance issues if it is required to use only a forth of the bandwidth it is currently using over analog radios. If a second radio network is implemented, the new radios will be required to meet the current FCC licensing standards. Some radio testing may be required to identify what digital technologies would work best with the City of Renton topology over 6.25KHz. • The Rugid protocol that is currently being used is not as much of an issue at this time but should be addressed in 5-10 years with the introduction of a new radio network running an open protocol. Rugid 9 controllers can continue to be used but the City will no longer be dependent on one brand at that time. 4. City Shops Backend HMI system The current backend HMI system for the WW/SW system consists of the following equipment: One master Rugid 9 PLC controller that is used to poll all of the remote WW/SW pumping stations. One primary and one backup HMI computer consisting of Wonderware InTouch software for viewing the system and SCADAlarm 5.04 for notifying operations staff of remote facility failures. One Industrial SQL server for collecting historical data and events for review by the operation or engineering staff. The existing master Rugid 9 PLC is about two years old and would still be required in any SCADA improvements for communicating with remote Rugid 6 and possibly Rugid 9 facilities on the original RNET 450MHz network. . HMI System Conclusions The Wonderware HMI software that is implemented on the wastewater and drinking water computers is considered one of the top brands in the world and will be supported for decades to come due to the large number of installed locations around the world and in the Pacific Northwest. Various software and hardware changes will be implemented in the near term to optimize this system even further. If a second radio communications network is implemented, another master PLC controller will probably be required to handle collecting data from the remote facilities. City Hall City Network City Shops Primary& Backup Wonderwale HMI Servers City Shops INSQL Firewall Server (Historical ° o Database) Existing Rugid 9 x< Master PLC fl"rirtT,e1"s -: I Report Printer Primary Autodialer RNET Radio Backup Autodialer 450MHz UHF Licensed Frequency (used by all facilities) � Lift Station I� Rugid 6 jUj West Hill (t�t) Repeater Rugid 6 Rugid 9 t� f i Lift Station (�) Rugid 6 � Lift Station((�'>� Rugidgid99 ' ,cvrrrcu� ' 17 ® +1 e Alarm Notification Voice, Pager City of Renton Wastewater SCADA System Block Diagrams 4-20-2007 .tile U +s Existing SCADA System CityHall City Shops Wonderware o HMI Server Report Printer p ---Alarm Notification �f ! .rd Voice, Pager Q. c•i \ih.>,.. Primary Auiodaler City �� ' City Shops INSCL r*, Network Firewall Server (Historical ° o m Backup AiA�dialer \ Database) RNET Radio t: ODI"t) N100BUS 450MHz UHF R _21 Ethernet New Radio Licensed Frequency rir„ Communications Equipment -" Existing Rugid 9 New Master PLC (unknown brand) Master PLC \, taia!s , L� MODBUS CornProtocol com Lift Station (r Lift Station ) Lift Station �) Rugid 6 Rugid 6 Rugid 6 0..__ . ry j Statio controls are New Lift I Lift Station n PLC New Lift Station PLC Rugid 9 Upgraded, they (unknown brand) (unknown brand) i R;lg'c+. 6 are moved from F�l t ,! :f old radio network MODBUS MODBUS o i _ I ;r k F.; to new radio network. Corn Protocol Con. Protocol Store &Forward Store & Forward SCADA Lift Station ( Lift Station ( ) ( ) ( ) Rugid6 Rugid6 System Upgrade Option New Lift Station PLC New Lift Station PLC (unknown brand) (unknown brand) I Michael Benoit HMI Upgrade Hardware Page 1 From: "Lee Tumbleson" <Iumbleson@RH2.com> To: "J.D. Wilson" <Jwilson@ci.renton.wa.us>, "Michael Benoit" <Mbenoit@ci.renton.wa.us> Date: 02/14/2007 4:53:12 PM Subject: HMI Upgrade Hardware Per the Scope of Work, Task 1, we submit for review the following: a) Provide City with specifications of RUGID Communications Board to purchase b) Specify Serial Communications switch box and cables for Water Bristol communications. c) Specify internal modems for Water SCADAIarm and cables and splitters for phone lines. d) Specify Spare Server for InSQL and RAID drive, these will sit on a shelf until needed. e) Specify rack/cabinet equipment f) Specify Serial Communications switch box and cables for Wastewater RUGID communications. g) Specify internal modems for Wastewater SCADAIarm and cables and splitters for phone lines. h) Provide a report outlining equipment and labor for a fully hot backup for all system components. a) Part number R9MDM ($185) b) http://www.trianglecables.com/2waydb9mansw.html ($9), http://www.trianglecables.com/cbl58.html ($4x2) As you may recall, we will be connecting a cable directly from the Bristol to the server and directly from the Bristol to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. c) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. d) Spare hard drive quote is coming (-$200?), see attached for server spec ($2,944) e) Rack/cabinet research is ongoing; we wanted to present the rest of the equipment while we finish that research. f) http://www.trianglecables.com/2waydb9mansw.html ($9), http://www.trianglecables.com/cbl58.htmi ($4x2) x Michael Benoit HM1-0 de Hardware Page 2 As you may recall, we will be connecting a cable directly from the RUG,ID to the server and directly from the RUGID to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. g) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. h) Report is not complete L. Lee Tumbleson, P.E. Control Systems Project Manager 425.951.5330 425.951.5331 fax RH2 Engineering, Inc. 12100 NE 195th St Suite 100 Bothell, WA 98011 800.720.8052 This message contains confidential information and is intended only for the addressed recipients. If you are not the addressed recipient you should not disseminate, distribute or copy this e-mail. Any views or opinions presented in this email are those of the author and may not represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: "James Swanson" <jswanson@RH2.com>, "Mark Miller" <mmiller@RH2.com> I-)bC C-ICL5r 0e,. 't t-tA,sT-1? tcc rz i307 0 P x-`ST Q.- -- " a •c a t- 3 A-2)O II I L "-' Go % -Z, v 't -v c 0 -- -5 -i ST N C 0'0 T&J J 2C r'C A-rc 2 s o .J 4+A Z,c J pg Page 1 chae( Benoit_ RE: HMI U rade Hardw are From: "Lee Tumbleson" <Itumbleson@RH2.com> To: "J.D. Wilson" <Jwilson@ci.renton.wa.us>, "Michael Benoit" <Mbenoit@ci.renton.wa.us> Date: 02/14/2007 4:56:34 PM Subject: RE: HMI Upgrade Hardware The RUGID will also need a COM cable and an extension to the PC. I updated item a) below. Lee From: Lee Tumbleson Sent: Wednesday, February 14, 2007 4:52 PM To:'J.D. Wilson; Michael Benoit Cc: James Swanson; Mark Miller Subject: HMI Upgrade Hardware Per the Scope of Work, Task 1, we submit for review the following: a) Provide City with specifications of RUGID Communications Board to purchase b) Specify Serial Communications switch box and cables for Water Bristol communications. c) Specify internal modems for Water SCADAIarm and cables and splitters for phone lines. d) Specify Spare Server for InSQL and RAID drive, these will sit on a shelf until needed. e) Specify rack/cabinet equipment f) Specify Serial Communications switch box and cables for Wastewater RUGID communications. g) Specify internal modems for Wastewater SCADAIarm and cables and splitters for phone lines. h) Provide a report outlining equipment and labor for a fully hot backup for all system components. a) Part number R9MDM ($185), CBL232 ($15), both from RUGID, http://www.trianglecables.com/25db9mf.html ($10) b) http://www.trianglecables.com/2waydb9mansw.html ($9), http://www.trianglecables.com/cbl58.htmi ($4x2) As you may recall, we will be connecting a cable directly from the Michael Benoit RE HMI Upgrade Hardware Page 2 Bristol to the server and directly from the Bristol to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. c) http://www.newegg.com/Product/Product.asp?Item=N82El6825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. d) Spare hard drive quote is coming (—$200?), see attached for server spec ($2,944) e) Rack/cabinet research is ongoing; we wanted to present the rest of the equipment while we finish that research. f) http://www.trianglecables.com/2waydb9mansw.htmi ($9), http://www.trianglecables.com/cbl58.htmi ($4x2) As you may recall, we will be connecting a cable directly from the RUGID to the server and directly from the RUGID to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. g) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. h) Report is not complete L. Lee Tumbleson, P.E. Control Systems Project Manager 425.951.5330 425.951.5331 fax RH2 Engineering, Inc. 12100 NE 195th St Suite 100 Bothell, WA 98011 800.720.8052 This message contains confidential information and is intended only for the addressed recipients. If you are not the addressed recipient you should not disseminate, distribute or copy this e-mail. Any views or opinions presented in this email are those of the author and may not represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: "James Swanson" <jswanson@RH2.com>, "Mark Miller" <mmiller@RH2.com> Michael Benoit RE HMI Upgrade Hardware . _ _ _ _ Page 1 From: "Lee Tumbleson" <Iumbleson@RH2.com> To: "J.D. Wilson" <Jwilson@ci.renton.wa.us>, "Michael Benoit" <Mbenoit@ci.renton.wa.us> Date: 02/15/2007 8:26:23 AM Subject: RE: HMI Upgrade Hardware $289 for the spare hard drive. This is a quote for RH2; the price may vary slightly when your IS Department requests a similar quote. Lee From: Lee Tumbleson Sent: Wednesday, February 14, 2007 4:56 PM To: 'J.D. Wilson'; 'Michael Benoit' Cc: James Swanson; Mark Miller Subject: RE: HMI Upgrade Hardware The RUGID will also need a COM cable and an extension to the PC. I updated item a) below. Lee From: Lee Tumbleson Sent: Wednesday, February 14, 2007 4:52 PM To: 'J.D. Wilson'; Michael Benoit Cc: James Swanson; Mark Miller Subject: HMI Upgrade Hardware Per the Scope of Work, Task 1, we submit for review the following: a) Provide City with specifications of RUGID Communications Board to purchase b) Specify Serial Communications switch box and cables for Water Bristol communications. c) Specify internal modems for Water SCADAlarm and cables and splitters for phone lines. d) Specify Spare Server for InSQL and RAID drive, these will sit on a shelf until needed. e) Specify rack/cabinet equipment f) Specify Serial Communications switch box and cables for Wastewater RUGID communications. Michael Benoit RELLHMI Upgrade Hardware r 4 _..._ _._ . _...__ Page 2 g) Specify internal modems for Wastewater SCADAlarm and cables and splitters for phone lines. h) Provide a report outlining equipment and labor for a fully hot backup for all system components. a) Part number R9MDM ($185), CBL232 ($15), both from RUGID, http://www.trianglecables.com/25db9mf.htmi ($10) b) http://www.trianglecables.com/2waydb9mansw.htmi ($9), http://www.trianglecables.com/cbl58.html ($4x2) As you may recall, we will be connecting a cable directly from the Bristol to the server and directly from the Bristol to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. c) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. d) Spare hard drive quote is coming (-$200?), see attached for server spec ($2,944) e) Rack/cabinet research is ongoing; we wanted to present the rest of the equipment while we finish that research. f) http://www.trianglecables.com/2waydb9mansw.htmi ($9), http://www.trianglecables.com/cbl58.html ($4x2) As you may recall, we will be connecting a cable directly from the RUGID to the server and directly from the RUGID to this switch box. The switch box will, in turn, be connected to both the primary and backup HMI computers. g) http://www.newegg.com/Product/Product.asp?Item=N82E16825104137 ($35x2), standard phone cables and splitters should be purchased to connect both modems to the wall jack simultaneously. h) Report is not complete L. Lee Tumbleson, P.E. Control Systems Project Manager 425.951.5330 425.951.5331 fax RH2 Engineering, Inc. 12100 NE 195th St Suite 100 Bothell, WA 98011 Michael Benoit RE HMI Upgrade Hardware Page 3 800.720.8052 This message contains confidential information and is intended only for the addressed recipients. If you are not the addressed recipient you should not disseminate, distribute or copy this e-mail. Any views or opinions presented in this email are those of the author and may not represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: "James Swanson" <jswanson@RH2.com>, "Mark Miller" <mmiller@RH2.com> Michael Benoit Quote 348322542.html Page 1-ill DELL QUOTATION QUOTE #: 348322542 Customer #: 897199 Quote Date: 2/15/07 Date: 2/15107 8:21:58 AM Customer Name: RH2 ENGINEERING TOTALQUOTE AMOUNT: Product Subtotal: $289.00 Tax: $25.87 Shipping & Handling: $4.99 Shipping Method: Ground Total Number of System Groups: 0 Product Quantity Unit Price Total 3GB 15K U320 SCSI Hard Drive,PV220, Customer Install (340-9377) 1 $289.00 $289.00 SALES REP: Jamie Grocki PHONE: 1800-901-3355 Email Address: Jamie_Grock!@Dell.com Phone Ext: 7958185 For your convenience, your sales representative, quote number and customer number have been included to provide you with faster service when you are ready to place your order. You may also place your order online at www.dell.com/quote This quote is subject to the terms of the agreement signed by you and Dell, or absent such agreement, Michael Benoit Quote 348322542.html is subject to the applicable Dell terms and conditions agreement. Prices and tax rates are valid in the U.S. only and are subject to change. Prices and tax rates are valid in the U.S. only and are subject to change. "Sales use tax is a destination charge, i.e. based on the "ship to" address on your purchase order. Please indicate your taxability status on your PO. If exempt, please fax exemption certificate to Dell Tax Department at 512-283-9239, referencing your customer number. If you have any questions regarding tax please call 800-433-9019. " All product and pricing information is based on latest information available. Subject to change without notice or obligation. LCD panels in Dell products contain mercury, please dispose properly. Please contact Dell's Asset Recovery Services group for EPA compliant disposal options at US_Dell_ARS_Requests@dell.com. Minimum quantities may apply. Dell recommends Windows Vista TM Business. View/Print Cart d� Print This Page PowerEdge 860 Date & Time: February 14,2007 6:20 PM CST PowerEdge 860 City Dual Core Intel® Pentium®D 915, 2.8GHz, 2x2MB Cache, 800MHz FSB, Windows Server® 2003 R2, Standard Edition, Unit Price $3,444.00 Includes 5 CALs Save $500 on select PowerEdge when priced $2,500 or - $500.0C above! Expires Thursday, February 22, 2007 Catalog Number: 4 BECWNK1 Module`' `Description Show Details PowerEdge 860 Dual Core Intel® Pentium®D 915, 2.8GHz, 2x2MB Cache, 800MHz FSB Operating System Windows Server® 2003 R2, Standard Edition, Includes 5 CALs Memory 1GB DDR2,533MHz, 1x1GB Dual Ranked DIMMs TCP/IP Offload Engine Broadcom® Dual Port TCP/IP Offload Engine Not Enablement Enabled Riser Card Riser with 2 Slots: 1 PCI Express x8 slot and 1 PCI Express x4 slot Primary Hard Drive 300GB, SAS, 3.5-inch, 1 OK RPM Hard Drive Primary Hard Drive SAS 51R internal RAID adapter, PCI-Express Controller Network Adapter On -Board Dual Gigabit Network Adapter, No TOE CD/DVD Drive 24X IDE CD-ROM Bezel Bezel Documentation No Hard Copy Documentation, E-Docs Only and OpenManage CD Kit 2nd Hard Drive 300GB, SAS, 3.5-inch, 10K RPM Hard Drive Hard Drive Configuration Add -in SAS5iR (SATA/SAS Controller) which supports 2 Hard Drives - RAID 1 Rack Rail Options No Rails Included Hardware Support 3Yr BASIC SUPPORT: 5x10 HW-Only, 5x10 NBD Services Onsite Installation Support No Installation Assessment Services 4, Sub -total $2,944.00 Shipping & Handling $19.99 Tax $260.85 Total Price $3,224.84 ' Afford the latest technology: Get More Details Estimate My Payments Pricing, specifications, availability and terms of offers may change without notice, are not transferable and are valid only for new purchases from this site for delivery in the 50 United States and the District of Columbia. Taxes, fees, shipping, handling and any applicable restocking charges extra, vary and are not subject to discount. This site and offers contained herei n valid only for end users and not for resellers and/or online auctions. Dell cannot be responsible for pricing or other errors, omissions, or consequences of misuse of site and its functions. Offers not necessarily combinable. Discounts cannot be retroactively applied. Orders subject to cancellation by Dell. Software and peripherals offers do not apply to software and pen pherals in the online system configuration pages ( including PowerConnect switches); you must purchase eligible items through the separate Software & Peripherals online store. Limit 5 systems and 5 discounted or promotional products per customer. If items purchased under these promotions are leased, items leased will be subject to applicable end of lease opti ons or requirements. If you have a separate purchase agreement with Dell the terms and conditions in that agreement are not applicable to purchases of ink, toner or other printer supplies made by you via www.dell.com/supplies; all such sales are subject to Dell's Terms and Conditions of Sale located at http://www.dell.com/terms, except for the provision(s) regarding separate purchase agreements. All other sales are subject to Dell's Terms and Conditions of Sale located at http://www.dell.com/terms. t Configuration, pricing, tax, shipping & handling and monthly payment information above is estimated and presented for your convenience only. All pricing, shipping and monthly payment information is subject to change without notice. Final order specifications and amounts, including tax and shipping & handling, will be communicated following receipt of your online order. Dell will not be responsible for typographical or other errors or omissions regarding prices or other information. Products displayed are available to US customers who take delivery in the 50 United States. All sales are subject to Dell's Term and Conditions of Sale. Copyright 1999-2007 Dell Inc. d Top Baff{ery Recall I About Dell I Conditions of Sale & Site Terms I Unresolved Issues I NEW Privacy Policy I Contact Us I Site Map I Visit ID t±) Large Text 1 1 f II I II 1 ' 2 �4•� lop,t ' �RiSTo` (c.> /aocs No vs� ctoUc �2 P2o�cs� C! ♦t � t2 A y `? F` INN RH2 ENGINEERING, INC http:llwww.rh2.com January 16, 2007 mailbox9rh2.com Mr. Mike Benoit 1.800.720.8052 City of Renton Planning/Building/Public Works 1055 S. Grady Way, 5th Floor Renton, WA 98055 WESTERN WASHINGTON 12100 NE 1951h St., Suite 100 Bothell, WA 98011 Sent Via: US Mail (tel) 425.951.5400 (tax) 425.398.2774 Subject: Wastewater/Stormwater SCADA System Review and Recommendations Dear Mike: 454 West Horton Road Bellingham, WA 98226 The attached memorandum is a basic review of the City's existing wastewater/stormwater —__(let)_360:676.0836_ __ SCADA-system-along-with various -recommendations:--Although-I--have-reviewed-most-of- (fax) 360.676.0837 the hardware/software used throughout the system, the main recommendations are communications related and how the City can become less dependent on Rugid PLC's. One Pacific Building The time -line Horizon and I are basing this review on, is over the next 10-20 years to help 621 Pacific Avenue, Suite 104 create an open SCADA system that is flexible, modular and inexpensive to upgrade and Tacoma, WA 98402 operate. If you have any questions, do not hesitate to contact me. (tel) 253.272.3059 Sincerely, 11­12 ENGINE NG, INC. EASTERN WASHINGTON 300 Simon Street SE, Suite 5 J 1 f East Wenatchee, WA 98802 i (tel) 509.886.2900 ames Swanson J (fax) 509.886.2313 CADA/Telemetry/Control Systems Manager JS/wr KITSAP PENINSULA Attachment: Wastewater/Stormwater SCADA System Memorandum 600 Kitsap Street, Suite 101 Port Orchard, WA 98366 (tel) 360.876.7960 (fax) 360.876.7988 01/16/07 6:48 AM JAdata\REN\l06-015\WW-SW SCADA Memorandum cover letter.doc City of Renton Wastewater/Stormwater SCADA System Future Requirements Review and Recommendations Memorandum The purpose of this memorandum is to review and recommend future requirements for the City's wastewater/stormwater SCADA system. These recommendations will be based on specific criteria that will allow the City to maintain and improve the existing SCADA system in a cost effective process. The current WW/SW SCADA system consists of four fundamental areas: 1. Monitoring and Control Instrumentation; 2. Facility Control Equipment; 3. Communications; and 4. City Shops Backend HMI System. When discussing each area of the existing SCADA system, the following items will be identified to help set priorities for future improvements. • Age of asset/Estimated life of asset • Current and future supportability of asset • Current or obsolete technology Monitoring and Control Instrumentation The current monitoring equipment used at the City's WW/SW pumping stations consists of the following. • Level - Level pressure transducers, high/low/emergency run float switches. • Flow - Calculated based on level at older facilities. Siemens Mag flow meters at the newer facilities. • Flood - Flood switches. • Smoke - Smoke alarms. • Check Valves - Limit Switches. • Pump Status - Run, Overload, Overtemp, Seal Failures from motor control center units. • Intrusion - Intrusion switches and intrusion override locks. All facilities use liquid level sensors for control purposes with back-up float switches in case of a level sensor or PLC controller failure. These instruments require regular cleaning maintenance but have shown themselves to be fairly robust compared to other level sensing technologies such as bubbler systems. The current level sensors are relatively easy to replace with dozens of different products available for many years in the future. All discrete (switch type) instruments, such as pump/motor status, check valve limit switches, flood switches, smoke alarms and intrusion switches have all worked very well and should have long life spans with easy replacements in case of failure. 1/16/2007 11:54 AM Page 1 of 5 1:\data\REN\106-0015\WW-SW SCADA System Memorandum.doc City of Renton Wastewater/Stormwater SCADA System Future Reauirements Review and Recommendations Memorandum The main limitation to the existing instrumentation is accurate flow monitoring from facilities that use the Rugid 6 PLC controllers that were installed in the early 1990s. The influent and effluent flows at these facilities are calculated based on level changes during pumping and non - pumping control periods. Unfortunately, these flow calculations fall apart during peak flows when the pumps may run for long periods of time due to heavy influent. Although this information is not critical from an operations point of view, this type of information is sometimes essential for issues such as calibrating flow modeling or helping to identify system I/I. If the need arises, these sites can easily be retrofitted for effluent Mag meters. Facility Control Equipment The current facility control equipment is made up of a primary control PLC with backup relay control in case of PLC or level sensor failure. The primary PLC technology is based on the Rugid line of controllers. These intelligent controllers are made in Olympia Washington by Rugid Computer Inc. The original controllers installed in the early 1990s have consisted of Rugid 6 PLCs. This line of controllers has been phased out over the last five years and replaced by the Rugid 9 PLC. All of the City's remote PLC controllers handle the following purposes. • Event and alarm monitoring. • Instrument monitoring and totalizing of flows, pump starts and run times. • Pump control based on wet well levels. • Radio communications of collected data back to the City Shops. The primary reason that the Rugid units were originally implemented for the wastewater system was their integral store and forward handling over low speed radio networks. This feature allows communications to be routed from the City Shops through multiple sites to reach facilities in difficult radio reception locations. At the time of the original installation, there were very few controllers that could handle this type of communication without extensive external equipment. Over the last 10 years, the most common approach to SCADA system design is to allow any brand of controllers to be added to the system by using standard communications protocols. The Rugid units; however, use a proprietary communications protocol standard with low overhead that allows up to three facilities to act as routers to reach any remote facility. This protocol is not available on any other controller brand. To this day, most standard communication r protocols that operate over low speed radio frequencies do not have this capability. ��•'`� c.{Sfi Although the current Rugid units are still easily supported by the vendor, the oldest Rugid 6 controllers will probably be difficult to replace or repair in the next 5-10 years. Also, by supporting more than one brand of controller, the City is not completely dependent on one tir a' manufacturer. It is recommended by this consultant that SCADA system changes should be r_� implemented in the next few years to allow other controller brands to be added to the WW/SW SCADA system. This will create a SCADA system that operates in much the way a modern F n computer network operates. Modern computer networks allow any type of equipment to be A'' added as long as it speaks a common network protocol. This will require changes in the current communications system that the WW/SW SCADA system is currently using. 1/16/2007 11:54 AM Page 2 of 5 JAdatalREM106-0151WW-SW SCADA System Memorandum.doc City of Renton Wastewater/Stormwater SCADA System Future Requirements Review and Recommendations Memorandum Communications Network The existing communications network for the WW/SW SCADA system consists of a master controller at the City Shops polling the remote facilities over a 450MHz radio network. This polling process that the master controller uses is a round robin process that polls all of the facilities over a period of about 21/2 minutes and then starts over again. Some of the remote sites can communicate directly with the master controller and some of the sites use a repeater site as a way of directing communications back to the City Shops through difficult topology. A simplified topology of Renton consists of the low laying areas close to Lake Washington heading down 167th to Auburn and a highlands area to the north and south of Maple Valley. When the original SCADA system was installed in the early 1990's, a repeater site was setup on the West Hill Reservoir to handle communications from the low lying areas near the lake back to the City Shops that was located in the highlands area north of Maple Valley. This repeater site worked reasonably well for the original facilities. As new sites where added to the east in the Highlands, it has became more difficult to get communications to these areas. Many of the Al current remote facilities in the eastern highlands areas are using other remote facilities as C"I 1L. repeaters to direct communications back to the City Shops. Phi J The current radio technology is based on the RNET radios from the 1980's and use frequency � %A.�� shift keying technology to send digital information via modulated radio signals. This type of �y c technology is somewhat obsolete for new 450 MHz radio networks that use more advanced communications technology that have been developed over the last decade. There are; however, so many RNET radios in use around the world that compatible radios should be available for at least a few decades. ,1,;',,�PO° yThe current radio network is also suffering from too many remote facilities using the same cs � � SG' frequency. As more facilities are added to this network, the time for the master controller to 10.) J+ -' complete a full poll of the remote sites has become fairly long for a typical SCADA system. A ;7 s It is the recommendation of this consultant that a second communications network be0's�'���p Y" 14 r. implemented in the near future that will host a standard PLC protocol If the new standard ° j a" ,< protocol is MODBUS, http://en.wikipedia.org/wiki/Modbus then any new controller or any of v �, �'� a x; the existing six Rugid 9 controllers can use this new communications network. P'n-m' � ,' V �''� > ` Most open standard protocols such as MODBUS do not inherently support the "Store and-° �an Forward technology that the Rugid units use to help with communicating to difficult locations. A New radio technology, however, has been implemented that takes this job away from the ,V*.> a1 w �L✓ controller and moves it directly into the radio network. If this network were to continue using the 450 MHz radio technology owned by the City, then a new repeater would be required at the West Hill Reservoir and another repeater should be implemented on the new Hazen Reservoir in the north highlands area. Each reservoir would then be able to host a repeater for the new standard PLC protocol. These changes would allow for any brand of controller to be used for future WW/SW lift stations while still supporting the existing Rugid controllers. If the existing Rugid 9 controllers in the eastern highlands area are not converted to the new MODBUS radio network, then another radio repeater similar to the existing West Hill repeater should be implemented on the new Hazen Reservoir. 1116n007 11:54 AM Page 3 of 5 J:\data\REMI06-015\WW-SW SCADA System Memormdum.doc City of Renton Wastewater/Stormwater SCADA System Future Requirements Review and Recommendations Memorandum Another option would be to use a leased radio communication medium such as WiMax, http://en.wikipedia.org/wiki/Wimax. If the City is hosting WiMax equipment on their reservoirs from companies such as Clearwire, they may be able to use their radio network for a lower cost than regular users. No mater what communications medium is selected, now or in the future, the City should choose the new PLC controllers that are flexible in their ability to interface with this technology. This flexibility consists of the following criteria. 1. Ability to communicate over a TCP/IP network either natively or with the use of converters. 2. Ability to communicate using the MODBUS protocol over a serial communications line or over a TCP/IP network. This is typically known as MODBUS/TCP. City Shops Back -end HMI system The current back -end HMI system for the WW/SW system consists of the following equipment. • One master Rugid 9 PLC controller that is used to poll all of the remote WW/SW pumping stations. • One primary and one back-up HMI computer consisting of Wonderware InTouch software for viewing the system and SCADAlarm 5.04 for notifying operations staff of remote facility failures. • One Industrial SQL server for collecting historical data and events for review by the operation or engineering staff. The existing master Rugid 9 PLC is about two years old and would still be required in any SCADA improvements for communicating with remote Rugid 6 and possibly Rugid 9 facilities on the original RNET 450 MHz network. If a second communications network is implemented, another master PLC controller will probably be required to handle collecting data from the remote facilities. The various Wonderware HMI software that is implemented on the wastewater and drinking water computers is considered one of the top brands in the world and will be supported for decades to come, due to the large number of installed locations around the world and in the Pacific Northwest. Various software changes will be implemented in the near term to optimize this system even further. Conclusion In conclusion, the primary recommendation of this SCADA system review is to add a second communications network that will host a standard PLC protocol such as MODBUS. This second communications network will at first open up the SCADA system to different PLC controller types and will take some of the workload off the existing radio network. The existing facilities can stay on the current 450 MHz radio network and new or upgraded facilities will use the new network. Also, the six existing Rugid 9 controllers can also communicate over any type of 1/16/2007 11:54 AM Page 4 of 5 J:\data\REN\106-015\WW-SW SCADA System Memorandum.doc City of Renton Wastewater/Stormwater SCADA System Future Requirements Review and Recommendations Memorandum communications network that hosts the MODBUS protocol. Eventually, this second communications network may end up replacing the existing radio network in 5 to 10 years. The amount of infrastructure necessary for this second network is dependent on the communications technology selected. At a minimum, a master unit and two radio repeater/router units at the West Hill and Hazen Reservoirs may be required. If no more Rugid 6 controllers are located to the east of the City Shops, then the existing radio repeater on the West Hill reservoir should be able to handle the existing radio network. 1/16/2007 11:54 AM Page 5 of 5 J:\data\REN\106-015\WW-SW SCADA System Memorandum.doc City Hall RNET Radio Network (used by all facilities) 450MHz Omni Directional Antenna Rugid 6 Com Protocol West Hill Repeater Rugid 6 Com Protocol " a 0 0 a I. C ass LOi i LOn ii Lift Station Repeater Rugid 6 Lift Station C> Rugid 6 Com Protocol City of Renton Shops Existing Rugid 9 Master PLC Lift Station All Remote Facilities use Yagi Antennas and 450MHz RNET Radios. Original Motorola Radios are crystal based units that are about 12 years old. New RNET radios are more advanced and come from Dataradio. MODBUS RS-232 Serial Communications =No As lift station controls are upgraded, they are moved from old radio network to new radio network. Wonderware HMI Servers MODBUS Ethernet Communications West Hill Reservoir Repeater City of Renton Wastewater SCADA Communications Upgrade Block Diagram New Master PLC (unknown brand) o MODBUS Com Protocol MODBUS \ Com Protocol All Remote Facilities use new radios with a new licensed frequency. All communications runs over MODBUS protocol. 1-20-2007 New Radio Equipment �c �) 450MHz Omni -Directional Antenna Hazen Reservoir Repeater Existing Rugid 9 I- Lift Station cc �r Existing Rugid 9 Lift Station New Lift Station PLC (unknown brand) New Lift Station PLC (unknown brand) C N I N C a. L N N C G f SCIC11 iSTi Exhibit A City of Renton Water and Wastewater Division HMI Upgrades at City Shops 2006 EXHIBIT A - Scope of Work The Scope of Work is expected to take place during December 2006. SCOPE OF WORK Task 1. SPECIFY EQUIPMENT FOR CITY TO PURCHASE a) Provide City with specifications of RUGID Communications Board to purchase b) Specify Serial Communications switch box and cables for Water Bristol communications. c) Specify internal modems for Water SCADAlarm and cables and splitters for phone lines. d) Specify Spare Server for InSQL and RAID drive, these will sit on a shelf until needed. e) Specify rack/cabinet equipment f) Specify Serial Communications switch box and cables for Wastewater RUGID communications. g) Specify internal modems for Wastewater SCADAlarm and cables and splitters for phone lines. h) Provide a report outlining equipment and labor for a fully hot backup for all system components. Task 2. INSTALL AND PROGRAM COMMUNICATIONS BOARD IN RUGID MASTER a) Install Communications Board into RUGID master PLC b) Program RUGID master PLC to use both communication boards Task 3. UPGRADE WATER HMI SOFTWARE a) Coordinate with Reid Instruments to enable additional (existing) communications port and configure runtime tags for pumps. b) Extend cable from Bristol secondary communications port to HMI computer communications switch box c) Configure SCADAlann modems and cables d) Install BSAP software on Primary and Backup Water HMI Computers e) Upgrade InTouch to 9.5 f) Configure InTouch. Change communication with the BSAP driver to the HMI computer (not the server). g) Set up combined flow rate tags and alarms for the wells per Ray's request on October 19, 2006. u/i6/o63:50 PM S:\DATA\REN\S40\2oo6 TELEMETRY AND SCADA SYSTEMS\RENTON HMI UPGRADE 2oo6 SCOPEDOC City of Renton Exhibit A - Scope of Work HMI Upgrades at City Shops 2006 Page 2 Task 4. UPGRADE WASTEWATER HMI SOFTWARE a) Extend cable from MODBUS secondary communications port to HMI computer communications switch box b) Configure SCADAlanm modems and cables c) Install MODBUS driver on Wastewater HMI computers d) Configure InTouch to communicate with the MODBUS driver on the HMI computer (not the server) Task 5. TESTING AND STARTUP e) Testing, startup, and commissioning of new equipment in the presents of the City. Includes testing the operation of the backup HMI server computer. f) Follow-up assistance. Schedule We propose to complete this work by the end of December 2006. n/16/2oo6, 3:50:36 PM S:\DATA\REN\S40\2oo6 TELEMETRY AND SCADA SYSTEMS\RENTON HMI UPGRADE 2oo6 SCOPE.DOC EXHIBIT B CITY OF RENTON Water and Wastewater Division HMI Upgrades at City Shops 2006 Estimate of Time and Expense Descri lion p Principal i Project I Computer i StaH Enginoor Engineering Engr. i Senior Planner Word Processor I 1 I Total Tercel Labor SubconsI' To. Total ' (.........................................................._._._............._......_...._._................_..._..._._._........_._..........._.............................. 1 .Manager Engineer i 1 Technician 1 Geologist i Hours Cost Classification Principal VII11 Professional VI Professional V Professional 11 1 Technician 11 1 Professional VI I Professional V 1 Administrable III Task 1 Specify Equipment for City to Purchase 1.1 Rugitl Comm Board ' 1.2 Water Switch Box and Cables - - - - - - - $ 8 - $ - 1.3 SCADAIarm Modems - - 0.5 - - 1 S 23 E - $ 1.4 Spare Server and RAID Drive .._}_.__.___...:...___....._}......._______________}...._....._._._..__........._} . .........'...._..._...__� _ .. 1 S 46 S - $ 15 Specify Rack/Cabinet Equipment - . 2 - - - - - 1.6 Wastewater Switch Box and Cables - - - - - - - .......____..........._:-.........._......_._.__.__.:..........._..._..___........:......._____._......_...F_____......_.______:-......___._-___.__.__ - 1.7 SCADAIarm Modems - - 0.5 i - - 1 $ 23 $ - S - 1.8 Provide Re ort to, Hot Backu .I .._._......_.___........ ......._._� .. ..._._._._..._.___�........_I........__._....__.______. 16 2 18 $ 736 $ - $ 18 SUbtotall 1 23 2 25 $ 1,0ss $ - S 18 Task J Upgrade Water HMI Software i i i 1 wd h R nstr nt 3. Coordination t e d I ume s _.____._..... _ ._._...._.___.__ _._.__.8 ...__... _._..._.........._.._.... _.._.__._.____. .._._...._.__.__._ ___...__._._._._._ _ _ .._...__ .._. .....I.._ _. _..}..... ........_. _._)._._ _._.}._._ ._...�_. ....... _ .. 8 $ 368 $ - $ 22 3.2 Configure BSAP switch box i - - 1 - ' _ ___ _ _ 1 $ 46 $ - S 3.3 ConBgure SCADAIarm motlems .._._._____.__....r...._____.".__.__.._..� - _ _ _ _.__.........I.._.__.__._.___._._.__r._._._._._._............_.__.(._.___._._._____.___I_____,..._._._._._.__...' ...._._.___..__...._._._... _ - 3.4 Install BSAP on HMI Computers r._._._._... Z 2 $ 92 $ ' $ 3.5 Upgrade In7ouch to 9.5 ............._._.............t........................................t..............._.......................1.................._.....................................__................t........................................I_._........................................................_................... - - 4 - ___._ .......___. }}....____..5....____...}....__.___............._......'..._._._._._._.__....___._._..__...___._____I_.___..____.__.........' ...... 4 S 184 S - E - 3.6 ConBgure InTouch 5 S 230 S $ 3.7 Screen Updates per RaySled Request ..__._.....:_._._.......r......._..__...-"'.__.._.._.'.(__._._._._..8.._..._._......I.._._.__......"................(....__...._._.'....__.._._._.}........_...._._._._._...................._...._...:_._._............(_......_._........: 8 $ 368 $ - $ 45 Subtotal 29 I 29 S 1,334 S - $ 67 Task 4 Upgrade Wastewater HMI Software 4.1 Configure MODBUS Switch box ... ... .............. .... _... - - - - - - t - �................._i........_.. .. .... 1 - 4.2 Configure SCADAIarm modem ............................._' ... .. ........ r.................. _.........._...._. .....1 - - 1 i - i - - - 4.3 Install MODBUS on HMI Computers - - 2 (. -( - . 4.4 Configure In7oucn ...r_................- ...................-......_..........i....._......._...-__._.__........_...._._........:__._.._....._ ..__.._.._._._...._._.i...._..._..__......................................................._.............._...._..................._.......i 5 5 S 230 $ $ Subtotal I S 4/4 1 S - S 22 Direct Salary Cost (DSC) 8 72 2 1 82 1 $ 3,694 1 S - I $ 152 OVERHEAD (OH Cost including Salary Additives OH Rate OH Rate x DSC 186.72% S 6,897 FIXED FEE (FF) FF Rate FF Rate x (DSC+OH) 12.00% S t,z71 SUBCONSULTANT TOTAL $ REIMBURSIBLES TOTAL I S 152 GRAND TOTAL 1 1 $ 12,014 Breakdown DSC OH Cost FF Rate Expense Total Wastewater $1,578 $2,946 S543 $76 $5,143 Water $2,116 $3,951 $728 $76 $6,871 $12,014 tcipal IX --__ _ S0.00 Technician IV _------_$0.00 tcipal Vlll_ Technician III___$0.00 tcipal — -- VII —___— _$66.75_ S0.00 Technician II _- S0.00 Technician 1 — --- — --_ $17.50 ----- — fessional V 1 $47.75 fessional V S46.00 Administrative V $0.00 fessional IV $3_.53 Administrative IV —_--_--_—$0.00 $0.00 ------^------ Administrative III fessional 111 S_31.60_ Administrative II -----------$11 $16.50 fessional 11-----------$26.85 --------------- ----- ------ Administrative 1 -------------------- 13 fessional I $21.75 use copies (each) 81/2" X I I" _ — use copies (each) 81/2" X_ 14"--__--_ S0.08_ use copies (each) 1 I" X 17" use copies (color) (each) 8 1/2" X 11" _ $0.85 use copies (color) (each) 8 1/2" X 14' SL50 use copies (color) (each) I I X 17' $1.70 (each sheet) ----- `__- _ $1.00__ use CAD System Per Hour $25.00 _ CAD Plots Lame ------- _____ $10.00 CAD Plots Full_Size $5.00 CAD Plots HalfSize _ $2.00 GIS System Per Hour $10.00 GIS Plots Per Plot S5.00 In-house Computer Per Hour $9 00 Mileage Per Mile _ Digital Camera Per Day -- —_$10.00 Digital Camera Per Week _S30.00 Digital Camera Per Month _ — $90.00 'Note: At project completion all digital photos can be supplied to the client on CD. upon request. 1 —T—H OA06+FwE-1— F.. Es NMI Sy—Upp .h El L-- EXHIBIT D City of Renton I I I I I I I Water and Wastewater Division HMI Upgrades at City Shops 2006 Project Costs Water Wastewater (Make/Model JCost JQuantity (Total JCost IQuantit (Total Internal Modems IConexant D15630-4 $ 25 1 2 $ 50 $ 25 1 2 1 $ 50 Telphone splitters/cables $ 20 1 $ 20 $ 20 1 $ 20 Serial Switch Box $ 10 1 $ 10 $ 10 1 $ 10 Serial Cables $ 10 2 $ 20 $ 10 2 $ 20 Standby SQL Server _ Dell PowerEdge SC440 $ 2,500 1/2 $ 1,250 $ 2,500 1/2 $ 1,250 Spare Server Hard Drive $ 300 1/2 $ 150 $ 300 1 1/2 $ 150 Server Cabinet $ 5,000 1/2 $ 2,500 $ 5,000 1/2 $ 2,500 Cabinet Fan/Filter $ 1,240 1/2 1 $ 620 $ 1,240 1/2 $ 620 RUGID Comm Board $ - $ 200 1 $ 200 Engineering/Programming $ 6,871 1 $ 6,871 $ 5,143 1 $ 5,143 I$ $ - I$ - I$ - $ 11,491 Mark Miller From: Lee Tumbleson Sent: Thursday, October 26, 2006 10:15 AM To: Raymond Sled Cc: J.D. Wilson; Mark Miller Subject: RE: Changes on Wonderware Ray, We can configure the instantaneous flow summaries in InTouch. However, yearly counters should be programmed at the facility, in Bristol. These counters will not be accurate if calculated at the Shops. Lee -----Original Message ----- From: Raymond Sled[maiIto: Rsled@ci..renton.wa.us) Sent: Thursday, October 19, 2006 10:42 AM To: Lee Tumba..eson Cc: J.D. Wilson; Mark Miller Subject: Changes on Wonder.ware Lee, I would like some screen changes. What I am locking for is to have all the flow rates from wells 1,2,&3 alarm if: they exceed 2200 gpm each. Then if the combinat:i.on of wells 1,2,&3 , 8,9, 11,12,17 flow rate exceed 11,400 it will send an alarm. Secondly I would l.i.ke to have run meters on all the well pumps and booster pumps that: would have a yearly run time and a total time that can be reset. Then can we have a spot for the reservoirs that will display the last time the reservoir was cleaned. It can be a manual input. If this is going to be costly please give me an estimate. Thanks Ray Ray Sled Wager Maintenance Manager City of Renton 425-430-7400 1 City of Renton HMI Architecture V City Network KVM RUGID Wastel IJ Waste2 A HMI HMI Printer HMI Network InTouch 9.5 _ ______(Private InTouch 9.5 (SCADA.net) SCADAIarm SCADAIarm 5.05 5.05 Existing HistData HistData Fr -I J. w - KVM RUGID t Wastel Waste2 HMI HMI InTouch 9.5 InTouch 9.5 Modbus Modbus SCADAIarm SCADAIarm 5.05 5.05 HistData HistData �s- Printer —_ Server Server _ Private HMI Network I_ (SCADA.net) InSQL 8 Shared Alternative Printer (City KVM w �l I Wastel Waste2 HMI HMI InTouch 9.5 InTouch 9.5 SCADAIarm SCADAIarm 5.05 5.05 HistData HistData ---- X RUGID a Printer Server A -----(Private HMI Networks (SCADA.net) Alternative IIIII IIIII !aa IIIII IIIII � � _�� Bristol InSQL 8 Bristol Modbus Shared Printer Water HMI [­ InTouch 9.0 SCADAIarm 5.05 HistData a f �s Water, HMI InTouch 9.0 SCADAIarm 5.05 HistData — —17 KVM - El - ;Ili IIIII ry Water2 Waterl llt Ilpl Bristol HMI HMI InTouch 9.5 InTouch 9.5 Bristol/BSAP Bristol/BSAP SCADAIarm SCADAIarm 5.05 5.05 HistData HistData IIIC 'IIII Illlf ills �-- -I Bristol KVM_ _ Water2 Waters Server B HMI HMI InSQL 8 InSQL 8 InTouch 9.0 InTouch 9.0 Bristol Bristol SCADAIarm SCADAIarm Modbus Modbus 5.05 5.05 Shared Shared HistData HistData Printer Printer 10/06/06 City of Renton HMI Architecture Waste1 HMI InTouch 9.5 InTouch 9.5 inbUL 6 InTouch 9.0 InTouch 9.0 SBristolCADAIarm 5.05 SCADAIarm 5.05 SCADAIarm-5.05 SCADAIarm 5.05 HistData HistData Existing Modbus HistData HistData Shared Printer in i oucn a.b in i oucn a.b in i oucn a.b in i oucn a.o Modbus Modbus InSQL 8 Bristol/BSAP Bristol/BSAP SCADAIarm 5.05 SCADAIarm 5.05 Shared Printer SCADAIarm 5.05 SCADAIarm 5.05 HistData HistData Proposed HistData HistData 10/06/06 Michael Benoit - Proposed Changes to HMI System located at City shops Page 1 From: "Mark Miller" <mmiller@RH2.com> To: <rshaffer@ci.renton.wa.us>, "Raymond Sled" <Rsled@ci.renton.wa.us>, <jwilson@ci.renton.wa.us>, "Michael Benoit" <Mbenoit@ci.renton.wa.us> Date: 10/27/2006 3:15:52 PM Subject: Proposed Changes to HMI System located at City shops Gentlemen, The attached Scope is to add redundancy and stability to the SCADA Back -end system in the City Shops. Ethernet is a communications protocol to move towards when upgrading PLC equipment, but at this time, it is much simpler to configure dual serial communications to the PLCs. Based on information from Reid Instruments, the Bristol has the necessary hardware to perform dual serial communications. The RUGID only requires a Comm Board which will cost about $200. The City will need to contract separately with Reid Instruments to enable communication on the second serial interface of the Bristol. As we discussed in the meeting, we will specify a backup hard drive for the RAID on the existing server and a backup server for InSQL. We will also provide a recommendation on a rack or cabinet configuration for all of the computers and equipment to provide a layer of protection from intrusion and environmental contaminants. A report will be created outlining the equipment and labor costs to provide a fully redundant hot backup for all system components. Cables and switch boxes will be introduced into the PLC and SCADAlarm cabling to switch from the Primary HMI computer to the Backup HMI computer without unplugging any cables. While performing these other upgrades, it is convenient to upgrade the Water InTouch software to the latest version, 9.5. If everyone agrees that this is how the City wishes to proceed please notify us that you wish us to proceed and how you would like to set up the contract. We could work under the two existing contracts that are related to telemetry projects. Those contracts are the Maplewood HMI upgrade and the 2004 Water Scada Improvements. We estimate a cost of $10,000 or less to complete the project. The $10,000 has 10 hours of extra time to deal with unforeseen issues. The scope and fee also has sufficient time to update the HMI screens has requested by Ray.l Thank you for the opportunity to continue to assist the City with their telemetry needs. We look forward to hearing back from you. Sincerely, MARK MILLER, P.E. I RH2 ENGINEERING, INC. PROJECT MANAGER Office 425.951.5372 1 Fax 425.951.5373 mmiller@rh2.com I www rh2.com <http://www rh2.com/> KC� Michael Benoit Proposed Changes to HMI System located at City shops Page 2 This message contains confidential information and is intended only for the addressed recipients. If you are not the addressed recipient you should not disseminate, distribute or copy this e-mail. Any views or opinions presented in this email are those of the author and may not represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: "Lee Tumbleson" <Itumbleson@RH2.com> Exhibit A City of Renton HMI UPGRADES 2006 EXHIBIT A — SCOPE OF WORK The Scope of Work is expected to take place during November 2006. SCOPE OF WORK Task 1. SPECIFY EQUIPMENT FOR CITY TO PURCHASES= a.. a) Provide City with specifications of RUGID Communications Board to purchase b) Specify Serial Communications switch boxes and cables for Water. (2) Switch boxes will be required, one for the Bristolland one for the SCADAIar�m modem. c) Spare Server for InSQL and RAID drivela d) Specify rack/cabinet equipment e) Specify Serial Communications switch boxes hand cables for Wastewater. (2) Switch boxes will be required, one for the RUGID and one for the SCADAIarm modem. x� s f) Provide a report outlining equipment and labor for a fullyhot backup for all system components.; Task 2. INSTALL AND PROGRAM COMMUNIC -IONS BOARD IN RUGID MASTER a) Install Communications Board into RUGID master PLC b) Program RUGID masterMkg to use bothilcommunication boards Task 3 ;.UPGRADE'�WATE atCoordinate with!Reid Instruments to enable additional (existing) communications port and configure runtime4tags for pumps. b) Etend cable from ° Bristol secondary communications port to HMI computer communications switch box c Configi&SCADA1arm modem switch box and cables d) Install BSWT, software on Primary and Backup Water HMI Computers e) Upgrade InTouch to 9.5 f) Configure InTouch. Change communication with the BSAP driver to the HMI computer (not the server). Set up combined flow rate tags and alarms for the wells. Task 4. UPGRADE WASTEWATER HMI SOFTWARE a) Extend cable from MODBUS secondary communications port to HMI computer communications switch box b) Configure SCADAlarm modem switch box and cables c) Install MODBUS driver on Wastewater HMI computers 10/27/o6 cos PM C:\DOCUDIENTS AND SETTINGS\MBENOIT\LOCAL. SETFINGS\TEMP\RE\TON HMI UPGRADE 20o6 SCC City of Renton Exhibit A - Scope of Work Wastewater SCADA Communications Analyses and Upgrades Page 2 d) Configure InTouch to communicate with the MODBUS driver on the HMI computer (not the server) Schedule We propose to complete this work by the end of November 2006. 10/30/2oo6, 8:26 AM C:\DOCUMENTS AND SETTINGS\MBENOIT\I.,OCAI. SE'ITINGS\TEMP\REN'TON HMI UPGRADE 20, Waste2 HMI KVM �witchl Box SCADAIarm Modem Faste l HMI InTouch 9.5 InTouch 9.5 SCADAIarm 5.05 SCADAIarm 5.05 Modbus Modbus HistData HistData Exhibit C City of Renton HMI Upgrade 2006 RH2 Engineering, Inc. Physical Diagram City Network 2j-_7 7 Printer IIIII :. 6na n7 Box IIIIIIIIII IIIIIIIIII Server Bristol Switch Box Private HMI Network (SCADA.net) InSQL 8 Bristol Modbus Shared Printer Red equipment is proposed -L Water. HMI Switch Box laterl HMI SCADAIarm Modem InTouch 9.0 InTouch 9.0 SCADAIarm 5.05 SCADAIarm 5.05 Modbus Modbus HistData HistData Michael Benoit RE telemetry question and status From: "Lee Tumbleson" <Iumbleson@RH2.com> To: "Michael Benoit' <Mbenoit@ci.renton.wa.us> Date: 09/11/2006 10:39:43 AM Subject: RE: telemetry question and status Before we installed the server, the only difference was that the MODBUS driver was installed on the HMI computer. We moved that to the server when the server was added. Lee -----Original Message ----- From: Michael Benoit[mailto:Mbenoit@ci.renton.wa.us] Sent: Monday, September 11, 2006 10:37 AM To: Lee Tumbleson Subject: RE: telemetry question and status What was the system before current (current being the layout instituted when we added the SCADA computer)? Ron is on the warpath because that is the point in time when "things changed and we started having problems" and he wants his control computers back to the way thing were pre SCADA. I would like to know what "that system" was just for the prospective of comparison for potential future changes and was it what Ron is remembering or closer to what our current is. Thanks Michael Benoit Wastewater Utility Engineer City of Renton (425) 430-7206 >>> "Lee Tumbleson" <Itumbleson@RH2.com> 09/11/06 10:24 AM >>> Jim and I have been brainstorming different options. We are now ready to schedule a meeting to discuss these options. The current system has the backup HMI computers networked to the primary computers. If the primary HMI failed, two cables needed to be moved from the primary to the backup and then the a desktop icon needed to be activated to initiate the backup. So, a manual swap. We also need to troubleshoot why the Rugid did not call out when the HMI failed. Lee -----Original Message ----- From: Michael Benoit[mailto:Mbenoit@ci.renton.wa.us] Sent: Monday, September 11, 2006 10:18 AM To: Lee Tumbleson Subject: telemetry question and status Just for my information, what is the status of the "future options of the telemetry" (based upon the bruha of the last few weeks) that laid Michael Benoit RE telemetry question and status µ _ Page 2 out the options and pros and cons of doing nothing, changing to what Shaffer had you working on, or other potential options? Before we added the scada computer to the mix, were the HMI computers linked such that if one went down the other kept operating the system? If so, was it automatic or a manual swap over? This seems to be the big sticking point in Shaffer's mind, so I would like to know how the world used to be. Thanks This message contains confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error -free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard -copy version. Any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the company. RH2 Engineering, Inc, www.rh2.com Michael Benoit Re Wonderware licenses Page 1 From: J.D. Wilson To: Lee Tumbleson Date: 08/23/2006 2:39:30 PM Subject: Re: Wonderware licenses Lee: We have these Licenses: In -Touch Development, 60K Tag, v9.5 License SN: 356605-4 / 39804 In -Touch Development, 60K Tag, v9.5 License SN: 356606-4 / 52137 InTouch Runtime, 60K Tag with 1/0 v9.5 License SN: 415909-4 Industrial SQL Server, Standard, 5000 Tag, v9.0 License SN: 746363-1 ActiveFactory Per Server, v9.1 = 2 Users License SN: 746364-1 InTouch Runtime, 3K Tag without 1/0 v9.5 License SN: 782025-2 SCADAIarm 6.0 License SN: 602638-1 SCADAIarm 6.0 License SN: 615688-1 When you complete doing the updates and before you leave Renton please call me so that I can verify the Active Factory Trends and Query still work on the desktops at City Hall. Thanks. J.D. J.D. Wilson, P.E. Utility / GIS Engineer Water Utility Engineering Section Utility Systems Division Planning /Building / Public Works Dept. City of Renton 5th Floor City Hall 1055 S. Grady Way Renton, WA 98055 425-430-7295 (V) 425-430-7241 (Fax) jwilson@ci.renton.wa.us F Michael Benoit Re Wonderware licenses Page 2 >>> "Lee Tumbleson" <Itumbleson@RH2.com> 08/23/06 2:07 PM >>> Do you have all of the latest licenses for InTouch(9.5) and SCADAlarm(6)? I'll be performing maintenance on both the Water and Wastewater HMI systems on Monday (include those tag descriptions that we discussed) and I'd like to apply those new licenses. If you have them, please email them to me. They are very small .lic files. — Thank you. - L. Lee Tumbleson, P.E. Project Manager 425.951.5330 425.951.5331 fax RH2 Engineering, Inc. 12100 NE 195th St Suite 100 Bothell, WA 98011 800.720.8052 This message contains confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error -free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard -copy version. Any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the company. RH2 Engineering, Inc, www.rh2.com CC: Abdoul Gafour; David Christensen; Michael Benoit; Raymond Sled; Ronald Shaffer J. ,Michael Benoit RET Onsite Service City of Renton 20070801 Page 1 From: "Jason Wagner"<jason.wagner@isswonderware.com> To: "Lee Tumbleson" <Itumbleson@RH2.com> Date: 08/01 /2006 1:53:15 PM Subject: RE: Onsite Service - City of Renton - 20070801 Hi Lee, There is no documentation that talks about the volume initialization string as far as I am aware. I found it on a search last night and the suggestion was provided by Multitech Technical Support. I cannot confirm whether or not this is a Multitech specific string, but seeing as it is an AT command, it most likely will apply to all modems. In the Scadalrm.ini file under the [Telephone Driver Parameters] header, there is a line called Phone Interface Options Bitmap=00000002. If you change the 2 to a 3, it will begin logging the modem command information to a file called vox_api.txt. Tech Note 431 has this information but a lot of the tech note is specific to Scadalarm 6.0. Jason From: Lee Tumbleson [mailto:ltumbleson@RH2.com] Sent: Tuesday, August 01, 2006 1:35 PM To: Jason Wagner Cc: cscottie@ci.renton.wa.us; rshaffer@ci.renton.wa.us; Evelyn Bundesmann; James Swanson; Mark Miller; jwilson@ci.renton.wa.us; Michael Benoit; rsled@ci.renton.wa.us Subject: RE: Onsite Service - City of Renton - 20070801 Thank you Jason. As for the script that you added to each tag, I'll be changing that to a QuickScript the next time I'm working on that system. The QuickScript will be called from each button and the QuickScript will perform those commands. X-0 � -0 CD �& /E//ƒJ ?E/%� %%2E $ \«> CEF 7E ? § 3 c 0-_-'=° gJ oaor = n-% x� n �. m= m=o J �. m C � g j = w m c o N)mom a e CD CD a_a_R° m CD ] m R n_.\ -0R&ƒ 5 �� $-\ CD_ � R°=nay cn �3 CDC) /kEf� /6Kc ® �// &a)_< /t �§\ S /0) 0 Cl(n0 o> �$ ww)3 e E_$ =J<$ »$ /�E \ a=ppf� �m Cn ��/7 % �0> �nmm mm o«5 5 E eE�t = 2= 2 CD x g/ �/ /\2CD \ \\ / \ \ \/CD 2 / \ / = a. « _ o g m CD _= a \ a 5] « . < \ƒ/f \ (n -. \$R $ ' $§/_\cc 0 c ] cr k] � / k\° 0 \ q a3 k- (_ < 7 om c CD ] § E2 0 mf e� \ o -S _ � �� / 7& (R ¢EJ\ \ �( 2 9 / C) \ /k / 2 \ / 3 k % k @$\J �\ CD 2 / / / 5' � n c 3 < ) 0 ƒ / o A > /R ' a ® R § § E 2 w a O 0 2 \ S � / $ % \ ° \ � \ \ = e § t = CD k_ ƒ> \ § CD k0/k / �� / A ° / § eR § t 2 § 0 ] m \ 6.0) _\ �0\k 7 m2 t S / k «S » = 3 o m = ) f § ° ~ 3 R</\ 07 e / c \$\ \/ < / / \ � / _ � q \ 2 I Michael Benoit RE: Onsite Service City of Renton 20070801 Page 3 iTrend ActiveX control had an issue and caused WindowViewer to fail. There was only one instance of this showing in the 20 days available in the Log. Other than this entry there isn't too much information that will help us narrow down the source of the problem. - In order to provide us with some additional information, I installed a Microsoft utility called Userdump. This utility will ,'monitor" any process and dump the contents of the memory when the process has an exception. I added view.exe and scalrm.exe to be monitored by this utility, so the next time that an exception occurs, we will have some additional information for Wonderware to look at. I put this utility on the primary Wastewater and the Water machines to be safe. When this issue occurs, please call into the Technical Support number and ask to speak with me so we can get those files. - Made a backup of the Water primary InTouch Application and placed it at C:\Scada20070801 - On the Water primary machine, as per our discussion on how the existing buttons work, I modified the window so that it can be toggled between appending the trend tags or replacing the trend tags. 0 1 added a button to the bottom right of the window that Toggles a discrete memory tag I created called WTR_AddToggle. Clicking this button will tell the other buttons whether to append the new trend tags or replace the existing. o On each of the existing buttons I added the following script portion before the existing action script. If WTR_AddToggle ==1 Then #iTrend Control 1.cleartagso ; Endif; - On the Water primary machine in order to increase the Scadalarm voice call volume, I added a modem initialization string AT#VGT=131 which will set the output volume of the modem higher (and from our test worked correctly.) - I enabled a logging option in the Scadalarm ini file that will log exactly what the modem is seeing and doing on both primary machines so that this can be compared against what is happening in the Michael Benoit RE Onsite Service City of Renton 20070801 _ Page 4 normal Scadalarm log file. This should give us more information the next time there is an issue with Scadalarm. - Lastly from both primary machines, I gathered the SMC Log File, the Windows Application Log file, the Scadalarm Log files so that I can review them further here. One thing that I did not do as I was not sure you wanted me to or even if I could, is copy the modified application from the primary water to the secondary water machine. If you would like the Append/Replace InTouch application changes on the secondary machine, yourself or Lee will need to copy the modified application over to the secondary machine. Also Evelyn had mentioned that you had mentioned some questions about Alarm filtering that I don't believe that we talked about. If you have questions about it still, please feel free to email me or give me a call. If you have any questions regarding any of this, please let me know. Thank you, Jason Wagner ISS Wonderware, Technical Department Technical Support: (425) 951-3262 General Phone: (425) 483-5111 Email: support@isswonderware.com Website: www.isswonderware.com <http://www.isswonderware.com/> For the most efficient responses, please direct all new technical Michael Benoit RE: Onsite Service - City of Renton 20070801 Page 5; support requests to: support@isswonderware.com or (425) 951-3262. This message contains confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. E-mail transmission cannot be guaranteed to be secure or error -free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard -copy version. Any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the company. RH2 Engineering, Inc, www.rh2.com <http://www.rh2.com> CC: <cscottie@ci.renton.wa.us>, <rshaffer@ci.renton.wa.us>, "Evelyn Bundesmann" <evelyn.bundesmann@isswonderware.com>, "James Swanson" <jswanson@RH2.com>, "Mark Miller" <mmiller@RH2.com>, <jwilson@ci.renton.wa.us>, "Michael Benoit" <Mbenoit@ci.renton.wa.us>, <rsled@ci.renton.wa.us> CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM DATE: May 6, 2004 TO: David Tibbojarware FROM: J.D. Wilson SUBJECT: Purchase of and Software for Water & Wastewater SCADA Uproject Please purchase the hardware and software described on the attached list for the Water & Wastewater SCADA Upgrade Project. Fund cites: Water: 421.000500.018.5960.0034.65.55120 / W.O.55121 Wastewater: 421.000400.018.5960.0035.65.045065 / W.O.45065 cc: Abdoul Gafour Dave Christensen Nenita Ching C:\Data Files\Projects\Upgrade SCADA HMI System\memo to Dave Tibbot 6 May 2004.doc\j List of Hardware & Software for IS to Order for Water and Wastewater SCADA Upgrade Server: Note from Lee Tumbleson at RH2: Please place this order over the phone to make sure that the drive controllers work with the drives in RAID 5 and that the tape drive has the proper controller and software. Please direct questions to Lee Tumbleson at 1-800-720-8052 ext 5330. Dell Server — PowerEdge 1600SC with the following features: • 3.06 GHz processor with 512 KB cache, 533 MHz FSB • 2.0 GB DDR SDRAM, 2 x 1 GB • Windows Server 2003 Standard Edition with 5 Client Licenses • Standard Windows Keyboard • No Monitor • Mouse • Electronic Documentation • 3.5 in, 1.44 MB Floppy Drive • 48X IDE CD-RW/DVD ROM Internal Drive • Primary Controller - PERC4-SC, 64MB, 1 Internal Channel (U320) (Call to verify!) • RAID Documentation - PERC4-SC, User Documentation — English • First Hard Drive: 73GB 1 OK RPM Ultra 320 68pin SCSI Hard Drive • Second Hard Drive: 73GB IOK RPM Ultra 320 68pin SCSI Hard Drive • Third Hard Drive: 73GB IOK RPM Ultra 320 68pin SCSI Hard Drive • Hard Drive Configuration: Cabled SCSI Drives (3 required) Connected to RAID Card, RAID 5 (Call to Verify!) • First Network Adapter — On Board Network Adapter • Second Network Adapter — Intel Pro I OOS w/ IPSEC Network Adapter • Tape Backup Unit - PV 1 IOT, DLT VS80, 40/80GB, Internal TBU, w/ Controller, w/ TapeWare Software (Call to verify!) • Tape Backup Media - DLVS80, 40/80G, 1 pack Tape Media • Tape Backup Software - TBU S/W TapeWare Enhanced Suite • Hardware Support Services - 3Yr Same Day 41-Ir Response Parts + Onsite Labor (7 Days x 24 Hours) Estimated cost: $7,388.48 + Tax = $8,038.67 Fund Cite: • Water: o Amount: $4,020 (Est) o Account: 421.000500.018.5960.0034.65.55120 / W.O. 55121 • Wastewater: o Amount: $4,020 (Est) o Account: 421.000400.018.5960.0035.65.045065 / W.O.45065 Page 1 of 2 Water System HMI Computer and Water System HMI Back-up Computer Dell Precision Workstation 360 Minitower (two systems) with the following features: • Intel@ Pentium@ 4 Processor 3.00GHz, 1MB / 800MHz FSB • MicrosoftO Windows@ XP Professional, SPl with Media and NTFS • 1GB,DDR400 SDRAM Memory, ECC (2 DIMMS) • 8OGB ATA-100 IDE, 1 inch (7200 rpm) • No Monitor • nVidia, Quadro NVS 280, 64MB, dual monitor VGA capable • Integrated Video • No Speakers • 48/32X CD-RW/DVD Combo with Roxio@ Easy CD Creator and DVD decode • 3.5 in, 1.44 MB Floppy Drive • 56K,v.92 data/fax modem, PCI • Keyboard: Enhanced Performance, USB (8 Hot Keys) • Mouse: Dell USB 2-Button Optical Mouse with Scroll • 3Yr Parts + Onsite Labor (Next Business Day) Estimated Cost: 2 x ($1,556.07 + Tax) = $3,386.00 Additional software to install on one box (installed by consultant): Microsoft Office Professional - $479.00 + tax = $522.00 Fund Cite: • Water: o Amount: $3,908.00 (Est) o Account: Account: 421.000500.018.5960.0034.65.55120 / W.O. 55121 Modems for SCADAlarm (2 for Water + 2 for Wastewater = 4 each): MultiTech MultiModem ZBA External Modem 56K V.90 data/fax modem - $150.00 + tax each Fund Cite: • Water: o Amount: $326.40 (Est) o Account: Account: 421.000500.018.5960.0034.65.55120 / W.O. 55121 • Wastewater: o Amount: $326.40 (Est) o Account: 421.000400.018.5960.0035.65.045065 / W.O.45065 Items for IS funded by Water and Wastewater: Fiber transceivers — 2 each: 2 x $700.00 + tax = $1,523.20 Simplex — 2 each: 2 x $700.00 + tax = $1,523.20 Fund Cite: • Water: o Amount: $1,523.20 (Est) o Account: Account: 421.000500.018.5960.0034.65.55120 / W.O. 55121 • Wastewater: o Amount: $1,523.20 (Est) o Account: 421.000400.018.5960.0035.65.045065 / W.O.45065 Page 2 of 2 Item Unit Cost Quantity SubTotal Tax Total Water Share Wastewater Share Dell PowerEdge 1600SC Server including OS and Tapebackup software $7,388.49 1 $7,388.49 $650.19 $8,038.67 $4,019.34 -- $4,019.34 Dell Precision 360 WorkStation $1,556.07 2 $3,112.14 $273.87 $3,386.01 $3,386.01 $0.1.00 External modems $150.00 4 $600.00 $52.80 $652.80 $326,40 $326.40 MS Office XP Pro $479.00 1 $479.00 $42.15 $521.15 $521.15 $0.00 Industrial SQL $10,795.00 1 $10,795.00 $949.96 $11,744.96 $5,872.48 $5,872.48 ActiveFactory $1,095.00 1 $1,095.00 $96.36 $1,191.36 $595.68 $595.68 Facto Suite FSCAL2000 $495.00 2 $990.00 $87.12 $1,077.12 $538.56 $538.56 Fiber Transceivers $700.00 2 $1,400.00 $123.20 $1,523.20 $761.60 _ $761.60 Fiber -Simplex $700.00 2 $1,400.00 $123.20 $1,523.20 $761.60 $761.60 Miscellaneous $200.00 1 $200.00 $17.60 $217.60 $108.80 $108.80 $29,876.07 $16,891.62 $12,984.46 raye i i .SY U�� CITY OF RENTON ♦ AM ♦ 1055 S. GRADY WAY RENTON, WA 98055 VENDOR: 068180 RH2 ENGINEERING INC 12100 NE 195TH ST #100 BOTHELL, WA 98011-5111 FOB Point: Terms: net term Req. Del. Date: Special Inst: -DATE = PO_ NUMBER 2/18/04 18/0000517 SHIP TO: Req. No.: Dept.: PLNG/BLDG/PUB WKS UTILITY SYS Contact: PHELAN, TERESA Pre -Assigned PO#?: NO .. CAG-04-019, Water & WW SCADA Upgrade, Water portion CAG-04-019, Water & WW Scada Upgrade, _ -— 18,101.35 7.000.00 t t c� 11 � � � • "' t ti c•• � - I s I - S e5 l 1 SUBTOTAL BILL TO: TAX FREIGHT TOTAL 25,101.35 0.00 0.00 25,101.35 E 421.000400.018.5960.0035.65.045065 5065/5160 — SF_t, �� "t } `, 0 E 421.000500.018.5960.0034.65.055120 5121 /5160 Authorized Signature Authorized Signature PFA iF S RECEIVED CCC ys�� __7 . T CITY OF RENTON ��IVSIL i i Y SYSTE-NIS —7 �� ( �"7nvoice To: City of Renton 1055 South Grady Way Renton, WA 98055 Attention: Teresa Phelan Project: 104044 Water System SCADA Upgrade Project Manager: Mark Miller Professional Services for the Period: 7/26/2004 to 8/29/2004 Billing Group: 01 Water System SCADA Upgrades CHARTER 116, LAWS OF 1965 [101] Specifications CITY OF RENTON CERTIFICATION I. THE UNDERSIGNED DO HEREBY CERTIFY UNDER PENALTY OF PERJURY, THAT THE MATERIALS HAVE BEEN FURNISHED, Reimbursables THE SERVICES RENDERED OR THE !.ABOR PERFORMED AS DEkMBED HEREIN, AND THAT CLAIM IS JUST, DUE AND In -House Computer UNPAID OBLIGATION AGA NST _ E CITY 0 RENTON, AND In -House Copies 8.5x 11 THAT I AM AUTH IZED T THENTI AT A CERTIFY TO SAID CLAIM. , imbursal SIGNED: h [102] PC Configurations Professional Services Professional IV Lee Tumbleson [103] HMI Changes Professional Services Professional IV Lee Tumbleson Administrative I Lea Littlefield RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400 / (800) 720-8052 Fax: (425) 398-2774 Invoice Number 39125 Invoice Date: September 14, 2004 CO Ct RRE CE DATE F N E rlf UDATE S o t Total: Specifications Totals: Billing Hours Billing Rate 33.00 103.36 Professional Services Total: 33.00 PC Configurations Totals: Billing Hours Billing Rate Amount 2.25 0.21 $2.46 $2.46 Amount 3,410.88 $3,410.88 $3,410.88 Amount 30.50 103.36 3,152.48 0.25 39.52 9.88 Professional Services Total: 30.75 $3,162.36 Page 1 RH2 Engineering, Inc. Project: 104044 [105] Project Management Professional Services Professional V Mark Miller Billing Group: 02 Fixed Fee Project Totals: Tuesday, September 14, 2004 Invoice: 39125 HMI Changes Totals: $3,162.36 BillingHours Billing Rate Amount 1.50 121.60 182.40 Professional Services Total: 1.50 $182.40 Project Management Totals: $182.40 Billing Group Total: $6,758.10 Contract Amount: $2,646.36 Percent Complete: 60.00% Fee Earned: $1,587.82 Prior Fee Billings: 529.27 Current Fee Total: $1,058.55 Billing Group Subtotal: 1,058.55 Billing Group T6tal. $1,058.55 * * * Total Project Invoice Amount. $7,816.65 Billing Summary Budge Prior Billed Current Invoice Budget Remaining $25,101.35 5,397.85 $7,816.65 $11,886.85 Page 2 £ N G t .c E. R g Billing Documentation To: City of Renton 1055 South Grady Way Renton, WA 98055 Project: 104044 Water System SCADA Upgrade Manager: Mark Miller Professional Services for the Period: 7/26/2004 to 8/29/2004 Billing Group: 01 Water System SCADA Upgrades 102 - PC Configurations Lee Tumbleson 7/26/2004 Configuring InSQL server. 8/3/2004 Configuring server. 8/4/2004 Configuring server. 8/10/2004 Configuring Server. 8/24/2004 Beginning on -site configuration of new hardware. 8/25/2004 On -site configuration on new hardware/software. 103 - HMI Changes Lee Tumbleson 7/27/2004 Configuring HMI PC. 7/28/2004 Configuring HMI PC. 7/29/2004 Configuring HMI PC. 8/12/2004 Configuring HMI PCs. 8/26/2004 On -site configuration of software and hardware. 8/27/2004 On -site configuration of software and hardware. RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400; (800) 720-8052 Fax: (425) 398-2774 Date: September 14, 2004 Invoice: 39125 Hours 4.00 4.00 4.00 4.00 7.00 10.00 Lee Tumbleson Total: 33.00 102 - PC Configurations Total: 33.00 4.50 4.00 4.00 4.00 9.00 5.00 Lee Tumbleson Total: 30.50 RH2 Engineering, Inc. Project: 104044 Lea Littlefield 8/24/2004 Filing 105 - Project Management Mark Miller 8/6/2004 Draft invoice review and project status review with staff. 8/12/2004 Project status update. 8/16/2004 Review project status with Lee. Billing Group: 02 Fixed Fee Invoice: 39125 September 14, 2004 Page 2 of 2 Lea Littlefield Total 103 - HMI Changes Total: Mark Miller Total 105 - Project Management Total: Total Professional Services Hours 0.25 0.25 30.75 0.50 0.50 0.50 1.50 1.50 65.25 Hours Reporting Period: RH2 Engineering, Inc. 6/28/2004 to 7/25/2004 RH2 Budget Report By Phase Selection: Project (Project ID Equal To'104044'?) City of Renton Budget Prior Current Budget 104044 Water System SCADA Upgrade Billed Charges Remaining Billing Group: [01] Water System SCADA Upgrade Phase: [101] Specifications Professional Services 1,315.22 1,133.06 0.00 182.16 Reimbursables 29.00 27.06 2.46 (0.52) SubConsultants 0.00 0.00 0.00 0.00 Phase 101 Total: 1,344.22 1,160.12 2.46 181.64 Phase: [102] PC Configurations Professional Services 8,443.55 3,410.88 3,410.88 1,621.79 Reimbursables 70.00 106.35 0.00 (36.35) SubConsultants 0.00 0.00 0.00 0.00 Phase 102 Total: 8,513.55 3,517.23 3,410.88 1,585.44 Phase: [103] HMI Changes Professional Services 6,154.53 0.00 3,162.36 2,992.17 Reimbursables 113.00 0.00 0.00 113.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 103 Total: 6,267.53 0.00 3,162.36 3,105.17 Phase: [104] Testing, Training Professional Services 4,031.77 9.62 0.00 4,022.15 Reimbursables 95.00 2.25 0.00 92.75 SubConsultants 0.00 0.00 0.00 0.00 Phase 104Total: 4,126.77 11.87 0.00 4,114.90 Phase: [ 105] Project Management Professional Services 2,107.92 179.36 182.40 1,746.16 Reimbursables 95.00 0.00 0.00 95.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 104 Total: 2,202.92 179.36 182.40 1,841.16 Billing Group 01 Totals Professional Services 22,052.99 4,732.92 6,755.64 10,564.43 Reimbursables 402.00 135.66 Z46 263.88 SubConsultants 0.00 0.00 0.00 0.00 22,454.99 4,868.58 6,758.10 10,828.31 Billing Group: [02] Fixed Fee Phase: [201] Fixed Fee Professional Services 2,646.36 529.27 1,058.55 1,058.54 Reimbursables 0.00 0.00 0.00 0.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 201 Total: 2,646.36 529.27 1,058.55 1,058.54 Billing Group 02 Totals Professional Services 2,646.36 529.27 1,058.55 1,058.54 Reimbursables 0.00 0.00 0.00 0.00 SubConsultants 0.00 0.00 0.00 0.00 2,646.36 529.27 1,058 55 1,058.54 Project 104044 Total: Professional Services 24,699.35 5,262.19 7,814.19 11,622.97 Reimbursables 402.00 135.66 2.46 263.88 SubConsultants 0.00 0.00 0.00 0.00 25,101.35 5,397.85 7,816.65 11,886.85 'SY U~s �T " CITY OF RENTON 1055 S. GRADY WAY RENTON, WA 98055 ��NTO VENDOR: 068180 RH2 ENGINEERING INC 12100 NE 195TH ST #100 BOTHELL, WA 98011-5111 FOB Point: Terms: net term Req. Del. Date: Special Inst: Page 1 1 Y WHOM wD- 2/18/04 18/0000517 SHIP TO: Req. No.: Dept.: PLNG/BLDG/PUB WKS UTILITY SYS contact: PHELAN, TERESA Pre -Assigned PO#?: NO CAG-04-019, Water & WW SCADA Upgrade, - 18,101.31,1 CAG-04-019, Water & WW Scada Upgrade, 7,000.0( t o (4 rz� . '-ts _156 BILL TO: SUBTOTAL TAX FREIGHT TOTAL 25,101 0 0 25,101 Account Number Work Order Function Number Amount E 421.000400.018.5960.0035.65.045065 5065/5160 18.141 E 421.000500.018.5960.0034.65.055120 5121/5160 Authorized Signature Authorized Signature NOV 0 8 2004 CITY OF RENTON UTILITY SYSTEMS To: City of Renton 1055 South Grady Way Renton, WA 98055 Attention: Teresa Phelan Project: 104044 DATE: YAME Invoice Water System SCADA Upgrade RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400 / (800) 720-8052 Fax: (425) 398-2774 1607o -h teeo--lf Invoice Number 39419 Invoice Date: November 05, 2004 Project Manager: Mark Miller CH/�RTER 116, LAWS OF 1965 Professional Services for the Period: 9/27/2004 to 10/24/2004 CITY OF RENTON CERTIFICATION 1 TUCpQH Billing Group: 01 Water System_.SCADA Upgrades OF PERJURY. THAT THE MATERE�18q ­RTIFY UNDER PENALTY HAVE BEEN FURNISHED, THE SERVICES RENDERED OR THE LABOR PERFORMED AS DESCRIBED HEREIN, AND THAT THE CLAIM IS JUST, DUE AND UNPAID OBAGAINST THE CITYTHAT I AM ALIRENTON AND [102] PC Configurations SAID CLAIMTHORI ED TO AUTHENTICATEOAND CERT TO SIGNED: SV Reimbursables N W' l a, U c zt Amount In -House Copies 8.5x11 0.91 [103] HMI Changes Professional Services Professional IV Lee Tumbleson [105] Project Management Professional Services Professional V Mark Miller Reimbursables Total: PC Configurations Totals: Billing Hours Billing Rate 6.50 103.36 Wvt $0.91 Amount 671.84 Professional Services Total: 6.50 $671.84 HMI Changes Totals: $671.84 Billing Hours Billing Rate 0.25 121.60 Professional Services Total: 0.25 Project Management Totals: Amoun 30.40 $30.40 $30.40 Page I RH2 Engineering, Inc. Project: 104044 Friday, November 05, 2004 Invoice: 39419 Billing Group: 02 Fixed Fee Billing Group Total. $703.15 Contract Amount: $2,646.36 Percent Complete: 90.00% Fee Earned: $2,381.72 Prior Fee Billings: 2,249.41 Current Fee Total: $132.31 Billing Group Subtotal: 132.31 Billing Group Total. $132.31 Project Totals: * * * Total Project Invoice Amount: Billing Summary Budget Prior Billed Current Invoice Budget Remaining $25,101.35 15,849.34 $835.46 $8,416.55 Outstanding Proiect Invoices Invoice Invoice Date Invoice Amt Payments/Credits Balance 39240 10/11/04 2,634.84 0.00 2,634.84 Total: 2,634.84 $835.46 Page 2 ti Y CITY OF RENTON ♦ '' ♦ 1055 S. GRADY WAY RENTON, WA 98055 INV VENDOR: 068180 RH2 ENGINEERING INC 12100 NE 195TH ST #100 BOTHELL, WA 98011-5111 FOB Point: Terms: net term Req. Del. Date: Special Inst: BILL TO: Page 1 1 DAT1 - PO<NUMB R- . ' 2/ 18/04 18/0000517 SHIP TO: PY Req. No.: Dept: PLNG/BLDG/PUB WKS UTILITY SYS Contact: PHELAN, TERESA Pre -Assigned POV: NO y Description CAG-04-019, Water & WW SCADA Upgrade, CAG-04-019, Water & WW Scada Upgrade, TTIIZZA Po may- ,R r` ��.tlds ► ' A-V v4,- _ A5 t � -, sAIM V 18,101.35 7,000.00 SUBTOTAL 25,101.35 TAX 0.00 FREIGHT 0.00 TOTAL 25,101.9 E 421.000400.018.5960.0035.65.045065 _ork Order Fcinctlon N_u_n 5065/5160 -- E 421.000500.018.5960.0034.65.055120 5121/5160 — u;fz�r - Authorized Signature Authorized Signature / RH2 Engineering, Inc 1 12100 NE ] 95th Street, Suite 100 Bothell, WA 98011 E 't. p y RECEIVED Phone: (425) 951-5400 / (800) 720-8052 ..,,..__........._ ___........... S I E N i ;: T S Fax: (425) 398-2774 �:. AUG 12 2.004 r CITY OF RENTON S&g�w ' 2,OOa .14 pSUfG 1 UTILITY SYSTEMS ` Invoice To: City of Renton 1055 South Grady Way Renton, WA 98055 Attention: Teresa Phelan Project: 104044 Water System SCADA Upgrade Project Manager: Mark Miller Professional Services for the Period: 6/28/2004 to 7/25/2004 Billing Group: 01 Water System SCADA Upgrades [102] PC Configurations Professional Services Professional IV Lee Tumbleson Reimbursables In -House Color Copies - 8.5x11 Mileage [105] Project Management Professional Services Professional V Mark Miller CHARTER 116, LAWS OF 1965 CITY OF RENTON CERTIFICATION I. THE UNDERSIGNED DO HEREBY CERTIFY UNDER PENALTY OF PERJURY. THAT THE MATERIALS HAVE BEEN FURNISHED, THE SERVICES RENCERED OR THE LABOR PERFORMED AS DESCRIBED HEREIN, AND "HAT T N_ , UNPAID OBLIGATION AGAINST Tyc CLAlly0, IS JUSTDUE AND CITY OF REN?ON, AND THAT I AM AUTHORIZED TO AUTHENTICATE AND C RTIFY TO SAID CLAIM. SIGNED: ►t/t/ 4 Invoice Number Invoice Date: DATE: 38958 August 10, 2004 Billing Hours Billing Rate Amount 33.00 103.36 3,410.88 Professional Services Total: 33.00 $3,410.88 Amount 68.85 18.00 Reimbursables Total: $86.85 PC Configurations Totals: $3,497 73 Billing Hours Billing Rate Amount 1.00 121.60 121.60 Professional Services Total: 1.00 $121.60 Project Management Totals: $121.60 Billing Group Total: $3,619.33 Page 1 RH2 Engineering, Inc. Project: 104044 Tuesday, August 10, 2004 Invoice: 38958 Billing Group: 02 Fixed Fee Project Totals: Contract Amount: $2,646.36 Percent Complete: 20.00% Fee Earned: $529.27 Prior Fee Billings: 132.32 Current Fee Total: $396.95 Billing Group Subtotal: 396.95 Billing Group Total: $396 95 *** Total Project Invoice Amount: Billing Summaa Budget Prior Billed Current Invoice Budeet Remaining $25,101.35 1,381.57 $4,016.28 $19,703.50 $4,016.28 Page 2 Billing Documentation To: City of Renton 1055 South Grady Way Renton, WA 98055 Project: 104044 Water System SCADA Upgrade Manager: Mark Miller Professional Services for the Period: 6/28/2004 to 7/25/2004 Billing Group: 01 Water System SCADA Upgrades 102 - PC Configurations Lee Tumbleson 7/l/2004 Preparing new HMI computer. 7/2/2004 Preparing InSQL server. 7/6/2004 Working on historical data import. 7/8/2004 Server configuration and tag list sorting. 7/12/2004 Sorting tag list and configuring server. 7/14/2004 Importing historical data. 7/22/2004 Importing historical data, configuring server. 105 - Project Management Mark Miller 7/6/2004 Coordinate work and schedule with programming team. 4 RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA P8011 Phone: (425) 951-5400; (800) 720-8052 Fax: (425) 398-2774 Date: Invoice: Lee Tumbleson Total: 102 - PC Configurations Total: Mark Miller Total: 105 - Project Management Total: Total Professional Services August 10, 2004 38958 Hours 6.00 6.00 3.00 4.00 4.00 4.00 6.00 �� Qi 33.00 1.00 1.00 1.00 34.00 Billing Group: 02 Fixed Fee Hours RH2 Engineering, Inc. Project: 104044 Invoice: 38958 August 10, 2004 Page 2 of 2 Hours Water System SCADA Upgrade REN 104.044 Erriployee ,_f_.,_,,,, , .,` Direct Salary Cost; OH Multiplier@204%;, : __,Billing Mark Miller $ 40.00 $ 81.60 $ 121.60 Lee Tumbleson $ 34.00 $ 69.36 $ 103.36 8/10/2004 4:48 PM CADocuments bKd Settings*roland\Desktop\REN 104044 Billing Rates.xls Reporting Period: RH2 Engineering, Inc. 6/28/2004 to.7/25/2004 RH2 Budget Report By Phase Selection: Project (Project ID Equal To'l04044'?) City of Renton 104044 Water System SCADA U Upgrade Budget Prior Billed Current Charges Budget Remaining Billing Group: [01] Water System SCADA Upgrade Phase: [101] Specifications Professional Services 1,315.22 1,133.06 0.00 182.16 Reimbursables 29.00 27.06 0.00 1.94 SubConsultants 0.00 0.00 0.00 0.00 Phase 101 Total: 1,344.22 1,160.12 0.00 184.10 Phase: [1021 PC Configurations Professional Services 8,443.55 0.00 3,410.88 5,032.67 Reimbursables 70.00 19.50 86.85 (36.35) SubConsultants 0.00 0.00 0.00 0.00 Phase 102 Total: 8,513.55 19.50 3,497.73 4,996.32 Phase: [103] HMI Changes Professional Services 6,154.53 0.00 0.00 6,154.53 Reimbursables 113.00 0.00 0.00 113.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 103 Total: 6,267.53 0.00 0.00 6,267.53 Phase: [1041 Testing, Training Professional Services 4,031.77 9.62 0.00 4,022.15 Reimbursables 950.00 2.25 0.00 947.75 SubConsultants 0.00 0.00 0.00 0.00 Phase 104 Total: 4,981.77 11.87 0.00 4,969.90 Phase: [105] Project Management Professional Services 2,107.92 57.76 121.60 1,928.56 Reimbursables 95.00 0.00 0.00 95.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 104 Total: 2,202.92 57.76 121.60 2,023.56 Billing Group 01 Totals Professional Services 15,913.30 1,200.44 3,532.48 11,180.38 Reimbursables 212.00 48.81 86.85 76.34 SubConsultants 0.00 0.00 0.00 0.00 16,125.30 1,249.25 3,619.33 11,256.72 Billing Group: [02) Fixed Fee Phase: [201) Fixed Fee Professional Services 2,646.36 132.32 396.95 2,117.09 Reimbursables 0.00 0.00 0.00 0.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 201 Total: 2,646.36 132.32 396.95 2,117.09 Billing Group 02 Totals Professional Services 2,646.36 132.32 396.95 2,117.09 Reimbursables 0.00 0.00 0.00 0.00 SubConsultants 0.00 0.00 0.00 0.00 2,646.36 132.32 396.95 2,117.09 Project 104044 Total: Professional Services 18,559.66 1,332.76 3,929.43 13,297.47 Reimbursables 212.00 48.81 86.85 76.34 SubConsultants 0.00 0.00 0.00 0.00 18,771.66 1,381.57 4,016.28 13,373.81 Page 1 1 U~ �� CITY OF RENTON ♦ 'y ♦ 1055 S. GRADY WAY RENTON, WA 98055 VENDOR: 068180 RH2 ENGINEERING INC 12100 NE 195TH ST #100 BOTHELL, WA 98011-5111 FOB Point: Terms: net term Req. Del. Date: Special Inst: -DATE PO NUMBER , 2/18/04 18/0000517 COPY Req. No.: Dept.: PLNG/BLDG/PUB WKS UTILITY SYS contact: PHELAN, TERESA Pre -Assigned POV: NO CAG-04-019, Water & WW SCADA Upgrade, CAG-04-019, Water & WW Scada Upgrade, tm - 18,101.35 7,000.00 IRMs OWN RMA SUBTOTAL 31LL TO: TAX FREIGHT TOTAL 25,101.35 0.00 0.00 25,101.35 MA Number, 7- Work Order Function Number E 421.000400.018.5960.0035.65.045065 5065/5160 E 421.000500.018.5960.0034.65.055120 5121/5160 Authorized Signature Authorized Signature APR 0 6 2 j14 �� iuk-C�'►' 4 �60. 65 GtMSE uska�J �2�5. �� t To: City of Renton 1055 South Grady Way Renton, WA 98055 Attention: Teresa Phelan Project: 104044 Water System SCADA Upgrade Project Manager: Mark Miller Professional Services for the Period: 2/23/2004 to 3/28/2004 Invoice Billing Group: 01 Water System SCADA Upgrades [101] Specifications Professional Services Professional IV Lee Tumbleson Reimbursables Mileage Billing Group: 02 Fixed Fee CHARTER 116, LAWS O'- - 965 CITY OF RENTON CERTIFICATP0114 I. THE UNDERSIGNED DO HEREBY CERTIFY UNDER FEPIAITl' OF PERJURY, THAT THE MATERIALS HAVE BEEN FURN' SHE1, THE SERVICES RENDERED OR THE LABOR PERFORMED AS DESCRIBED HEREIN, AND THAT THE CLAIM IS JUST, DUE AND UNPAID OBLIGATION .AGAINST THE CITY OF RENTON, AND THAT I AM AUTHORIZED TO AUTHENTICATE AND C^ IFY TO SAID CLAI SIGNED. S-0, 1411u0� RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400 / (800) 720-8052 Invoice Number: 38257 Invoice Date: April 05, 2004 Billing Hours Billing Rate 9.50 100.72 Professional Services Total: 9.50 Reimbursables Total: Specifications Totals: Billing Group Total: Contract Amount: Percent Complete: Fee Earned: Prior Fee Billings: Amount 956.81 $956.81 Amount 20.26 $20.26 $977.07 S977. 07 $2,646.36 3.00% $79.39 0.00 Page 1 RH2 Engineering, Inc. Project: 104044 Project Totals: Monday, April 05, 2004 Invoice: 38257 Current Fee Total: $79.39 Billing Group subtotal: 79.39 Billing Group Total: $79.39 *** Total Project Invoice Amount: $1,056.46 Billing Summary Budget Prior Billed Current Invoice Budget Remaining $25,101.35 $0.00 $1,056.46 $24,044.89 Page 2 RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400; (800) 720-8052 Fax: (425) 398-2774 Billing Documentation To: City of Renton Date: April 05, 2004 1055 South Grady Way Invoice: 38257 Renton, WA 98055 Project. 104044 Water System SCADA Upgrade Manager: Mark Miller Professional Services for the Period: 2/23/2004 to 3/28/2004 Billing Group: 01 Water System SCADA Upgrades Hours 101- Specifications Lee Tumbleson 2/4/2004 SCADA Upgrade coordination meeting with City 2.00 2/17/2004 SCADA-InSQL: compiling quotes and specs for hardware and software 3.00 purchase 2/26/2004 Meeting with Ron Hansen regarding network connectivity between City Hall 3.00 and SCADA SQL Server. 3/l/2004 Preparing the specficiations for equipment purchase. 0.50 3/3/2004 Preparing the specficiations for equipment purchase. 1.00 Lee Tumbleson Total: 9.50 101- Specifications Total: 9.50 Total Professional Services 9.50 Billing Group: 02 Fixed Fee Hours Page 1 1 Y CITY OF RENTON ♦ ♦ 1055 S. GRADY WAY RENTON, WA 98055 VENDOR:068180 RH2 ENGINEERING INC 12100 NE 195TH ST #100 BOTHELL, WA 98011-5111 FOB Point: Terms: net term Req. Del. Date Special Inst: 2/18/04 18/0000517 SHIP TO: Copy Req. No.: Dept: PLNG/BLDG/PUB WKS UTILITY SYS Contact: PHELAN, TERESA Pre -Assigned PO#?: No tran r ,_ ow ...P. CAG-04-019, Water & SCADA Upgrade, � _ . -_. - -x� s 18,101.35 :VVW CAG-04-01�9, Water & Scada Upgrade, 7.000.00 r tt O •, l SUBTOTAL ;ILL TO: TAX FREIGHT TOTAL 25,101.35 0.00 0.00 25,101-35 � Account Number Work Order Function Number E 421.000400.018.5960.0035.65.045065 5065/5160 E 421.000500.018.5960.0034.65.055120 5121 /5160 — 7, I O (_D , lQ� 5 Authorized Signature AutGo ze- _d�i_g nature u"hR FER 116, LAWS Ur 19605 RH2 Engineering, Inc. CITY OF RENTON CERTIFICATION 12100 NE 195th Street, Suite 100 I THE UNDERSIGNED DO HEREBY CERTIFY UNDER PENALTY Bothell, WA 98011 OF PER;URY, THAT THE MATERIALS HAVE BEEN FURNISHED, Phone: (425) 951-5400 / (800) 720-8052 THE SERVICES RENDERED OR THE DESCRIBED HEREIN. AND THAT THE CLAIM M OR is JUST,, DUCE AND AS Fax: (425) 398-2774 UNPAID OBLIGATION AGAINST THE CITY OF RENTON, AND THAT I AM RECEIVE® SAID CLAIM Y TO UTHORIZED TO AUTHENTICATE AND CERTIFY �C"S3 MAY 7 e 2004 :,iGNED: 4 G��S��alo�' 1 �` � t �� CITY OF RENTON unLOY sysTEW Invoice To City of Renton 1055 South Grady Way Renton, WA 98055 Attention: TeresaPhelan Project: 104044 Water System SCAM; Upgrade Project Manager: Mark Miller Professional Services for the Period: 3/29/2004 to 4/25/2004 Billing Group: 01 Water System SCADA Upgrades [101] Specifications Professional Services Professional IV Lee Tumbleson Reimbursables In -House Color Copies - 8.5x11 [102] PC Configurations Reimbursables Mileage [104] Testing, Training Professional Services Administrative I Lea Littlefield Invoice Number: 38417 Invoice Date: May 06, 2004 DATE ` lK AME VI)AUDATE 7AA% ho Billin¢ Flours Billing Rate Amount 1.75 100.71 176.25 Professional Services Total: 1.75 $176.25 Amount Reimbursables Total: Specifications Totals: Reimbursables Total: PC Configurations Totals: Billing Hours Billin¢ Rate 0.25 38.48 $183.05 Amount 19.50 $19.50 $19.50 Amount 9.62 Page 1 RH2 Engineering, Inc. Project: 104044 Testing, Trainin_g Continued... Reimbursables In -House Computer [1051 Project Management Professional Services Professional V Mark Miller Billing Group: 02 Fixed Fee Project Totals: Thursday, May 06, 2004 Invoice: 38417 Professional Services Total: 0.25 $9.62 Reimbursables Total: $2.25 Testing, Training Totals: $11.87 Billing Hours Billing Rate Amount 0.50 115.52 57.76 Professional Services Total: 0.50 $57.76 Project Management Totals: $57.76 Billing Group Total: $272.18 Contract Amount: $2,646.36 Percent Complete: 5.00% Fee Earned: $132.32 Prior Fee Billings: 79.39 Current Fee Total: $52.93 Billing Group Subtotal: Billing Group Total: 52.93 $52.93 *** Total Project Invoice Amount: $325.11 Page 2 RH2 Engineering, Inc Project: 104044 Billing Summary Bud et $25,101.35 Outstanding Project Invoices Thursday, May 06, 2004 Invoice: 38417 Current Invoice Budget Remaining $325.11 $23,719.78 Invoice Invoice Date Invoice Amt Payments/Credits Balance 38257 Total: 04/05/04 1,056.46 �60—_` 1,056.46 OStr4C`, ` Page 3 RH2 Engineering, Inc. 12100 NE 195th Street, Suite 100 Bothell, WA 98011 Phone: (425) 951-5400; (800) 720-8052 Fax: (425) 398-2774 Billing Documentation To: City of Renton Date: May 06, 2004 1055 South Grady Way Renton, WA 98055 Invoice: 38417 Project: 104044 Water System SCADA Upgrade Manager: Mark Miller Professional Services for the Period: 3/29/2004 to 4/25/2004 Billing Group: 01 Water System SCADA Upgrades Hours 101 - Specifications Lee Tumbleson 4/22/2004 Meeting at the City to determine the firewall requirements for remote access to 1.75 the SQL data from Pulic Works at City Hall. Lee Tumbleson Total: 1.75 101 - Specifications Total: 1.75 104 - Testing, Training Lea Littlefield 3/31/2004 Filing. 0.25 Lea Littlefield Total: 0.25 104 - Testing, Training Total: 0.25 105 - Project Management Mark Miller 4/5/2004 Draft invoice review for accurancy. 0.50 Mark Miller Total: 0.50 105 - Project Management Total: 0.50 Total Professional Services 7 en RH2 Engineering, Inc. Project: 104044 Invoice: 38417 May 06, 2004 Page 2 of 2 Hours Billing Group: 02 Fixed Fee Hours Reporting Period: RH2 Engineering, Inc. 3/29/2004 to 4/25/2004 RH2 Budget Report By Phase Selection: Project (Project 1D Equal To'104044'?) City of Renton Prior Current Budget _104044 Water System SCADA Upgrade Budge: Billed Charges Remaining Billing Group: [01] Water System SCADA Upgrade Phase: [ 101 ] Specifications Professional Services 1,315.22 956.81 176.25 182.16 Reimbursables 29.00 20.26 6.80 1.94 SubConsultants 0.00 mWm y1,344.22� 0.00 - 0.00 0.00 Phase 101 Total: 977.07 183.05 ^ 184.10 Phase: [102] PC Configurations Professional Services 8,443.55 0.00 0.00 8,443.55 Reimbursables 70.00 0.00 19.50 50.50 SubConsultants 0.00 0.00 0.00 0.00 Phase 102 Total: 8,513.55 0.00 19.50 8,494.05 Phase: [103] HMI Changes Professional Services 6,154.53 0.00 0.00 6,154.53 Reimbursables 113.00 0.00 0.00 113.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 103 Total: 6,267.53 0.00 0.00 6,267.53 Phase: [104] Testing, Training Professional Services 4,031.77 0.00 9.62 4,022.15 Reimbursables 95.00 0.00 2.25 92.75 SubConsultants _ 0.00 -- 0.00 0.00 0.00 Phase 104 Total: 4,126.77 0.00� _ 11.87 4,114.90 Phase: [105] Project Management Professional Services 2,107.92 0.00 57.76 2,050.16 Reimbursables 95.00 0.00 0.00 95.00 SubConsultants 0.00 0.00 0.00 0.00 Phase 105 Total: 2,202.92 0.00 57.76 2,145.16 Billing Group 01 Totals Professional Services 21,052.99 956.81 243.63 20,852.55 Reimbursables 402.00 20.26 28.55 353.19 SubConsultants 0.00 0.00 0.00 0.00 22,454.99 977.07 272.18 21,205.74 Billing Group: [02] Fixed Fee Phase: [201] Fixed Fee Professional Services 2,646.36 79.39 52.93 2,514.04 Reimbursables 0.00 0.00 0.00 0.00 SubConsultants 0.00 0.00 0.00_ 0.00 Phase 201 Total: 2,646.36 79.39 52.93 2,514.04 Billing Group 02 Totals Professional Services 2,646.36 79.39 52.93 2,514.04 Reimbursables 0.00 0.00 0.00 0.00 SubConsultants 0.00 0.00 0.00 0.00 2,646.36 79.39 52.93 2,514.04 Project 104044 Total: Professional Services 24,699.35 1,036.20 296.56 23,366.59 Reimbursables 402.00 20.26 28.55 353.19 SubConsultants ---0.00 0.00 0.00 0.00 25,101.35 1,056.46 325.11 23,719.78 • : f .. .. _... }... ....... .. .. .. ...�. ... :....:....:.... _ .. ,� ............. rJ/` :... ...:... ...:... ...: ... ... ... ... ... .......... :(1......:........:......... ... ...:... ...:... .........................:.........:.........:............... ......................... .. ................... ... ... :... ...:......:......:... H a rn :F i ..LAJJ ........:........:.........:........?.........:........:........:................ ... ... ... ... .. ... ... ... ... ... ... ... ... ... ... ... .. ... ... ... ... ... ... ...... i-wo.:5 . .�.... ....... i :.........:........:.................:........:........:........ ?........:.........:...... ... ... L :... i i i... :p .. .. .. .................................... .................. ... ................... ... ... ... .. .................................................................:......... ...:......:... ......:......:......: ......:... ............ ............ ........... i :....:....:.... _... :�.. .. .. .. _ r .....:......:.....:.....:...... :......:......:... ..........:A►..........................................................................................�.... �i i �-_.-i;-- Page 1 1 CITY OF RENTON 1055 S. GRADY WAY RENTON, WA 98055 VENDOR: 037302 ISS WONDERWARE 18939 120TH AVE NE - STE 111 BOTHELL, WA 98011 FOB Point: Terms: net term Req. Del. Date: Special Inst: DATE PO NUMBER 6/11 /2004 18/0000604 SHIP TO: copy Req. No.: Dept.: PLNG/BLDG/PUB WKS UTILITY SYS Contact: PHELAN, TERESA Pre -Assigned PO#?: No Quantity Unit Description Unit Price Ext Price THIS IS A REVISED PURCHASE ORDER Water/WW Telemetry Hardware, 7,604.32 IndustrialSQL, ActiveFactory, FactorySuite, #Q306127-3 Water/WW Telemetry Hardware, 7,604.32 lndustrialSQL, ActiveFactory, FactorySuite, #0306127-3 "'. _ AM SUBTOTAL 15 208.64 O.00 BILL TO: TAX 0.00 FREIGHT 15,208.64 TOTAL Account Number Work Order Function Number Amount E 421.000400.018.5960.0035.65.045065 5065/5160 7,604.32 E 421.000500.018.5960.0034.65.055120 5121/5160 7,604.32 Authorized Signature Authorized Signature INDUSTRIAL SOFTWARE SOLUTIONS ISS-Wonderware 18939 -120th Avenue NE, Suite 111, Bothell WA 98011 (Phone)425-483-5111 (Fax) 425-483-5789 Sold To: City of Renton 1055 South Grady Way Renton, WA 98055 0 -, . C 6 INVOICE NUMBER: 306127 U- INVOICE DATE: Jun 18, 2004 Ship to: City of Renton J.D. Wilson 425-430-7295 1055 South Grady Way Renton, WA 98055 RECEIVED 1 2004 p, T`i OF RENTON � {Ttt I-ry SYSTcMS Customer ID Customer PO Payment Terms City of Renton 18-0000604 Net 30 Days Sales Rep ID Shipping Method Ship Date Due Date WA-W UPS Ground 6/18/04 7/18/04 Quantity Item Description Unit Price Extension 1.0 17-0134 1nSQL Server-5K Tag, V8.0 10,795.00 10,795.0 License SN:746363-0 2.0 17-1009 ActiveFactory Per Server/Concurrent, V8.5 1,095.00 2,190.0 License SN:746364-0 2.0 17-0092 SCAL2000, Single 495.0 990.0 Paper License SN:746365-0, 746366-0 1.00 Shipping 3.53 3.53 e above referenced licenses have been added to your current support contract, # 30756 expiring 12/31/04. 'JUN 2 2004 City of Renton Accoun% Subtotal 13,978.53 Sales Tax 1,230.11 Make checks payable to: ISS-Wonderware Payment Received 0.00 Remit to: 18939 -120th Avenue NE, Suite 111, Bothell WA 98011 TOTAL Amount Due 15,208.64 Lost or stolen software licenses incur replacement costs of 80% of original purchase price. We suggest that you insure them against theft, loss and damage. All Wonderware products and services are provided with the specific understanding that your use ofthe software shall be in strict accordance with the terms and conditions of the Wonderware Corporation License Agreement including the restrictions on copying use, transfer, assignment, modification, installation, sublicense, upgrades, and limitation ofwarmn ties and liabilities. Without in anyway limit mgany of the other provisions ofthis order, you agree that in using the software you shad comply with, be bound by and liable for all the obligations ofevery kind and description contained in the Wonderware Corporation License Agreement. ISS-Wooderw are liability and obligations to you are likewise expressly con fined by the limitations contained in the Wonderware License Agreement You are cautioned to read such Agreement before installing or using the software. INDUSTRIAL SOFTWARE SOLUTIONS LA 18939 - 120th Avenue NESuite 111 ' Bothell, WA 98011 (Phone) 425-483-5111 (Fax) 425-483-5789 Sold To: City of Renton 1055 South Grady Way Renton, WA 98055 V 9 V Packinq List Number: 306127 Packinq List Date: Jun 18, 2004 Ship To: RECEIVED City of Renton J.D. Wilson 425-430-7295 J U N 2 12004 1055 South Grady Way CITY OF RENTON Renton, WA 98055 UTILITY SYSTEMS Customer ID PO Number Sales Rep Name City of Renton 18-0000604 Evelyn Bundesmann Customer Contact Shipping Method Pavment Terms J. D. Wilson UPS Ground Net 30 Days Quantitv Item Description This Shipment Backorder 1.00 17-0134 InSQL Server-5K Tag, V8.0 License SN:746363-0 2.00 17-1009 ActiveFactory Per Server/Concurrent, V8.5 License SN:746364-0 2.00 17-0092 FSCAL2000, Single Paper License SN:746365-0, 746366-0 1,00 Shipping The above referenced licenses have been added to your current support contract, # 30756 expifing 12/31/04. Lost or stolen software licenses incur replacement costs of 80% of original purchase price. We suggest that you insure them against theft, loss and damage. All Wonderware products and services are provided with the specific understanding that your use ofthe software shall be in strict accordance with the terms and conditions of the Wonderw are Corporation License Agreement, including the restrictions on copying, use, transfer, assignment, modification,: installation, sublicense, upgrades, and limitation of warranties and liabilities. Without in anyway limiting any of the other provisions ofthis order, you agree that in using the software you shall comply with, be bound by and liable for all the obligations ofevery kind and description contained in the Wonderware Corporation License Agreement. ISS-Wouderw are liability and obligations to you are likewise expressly confined by the limitations contained in the Wonderware License Agreement. You are cautioned to read such Agreement before installing or using the software. Wonderware® Corporation License Certificate City of Renton Water Utility Renton, Washington 98055 UNITED STATES WWOrder# 136622/ Dist: 000069/ PO# 51571 License Certificate # 140293 IMPORTANT - READ CAREFULLY: This License Certificate represents a Wonderware license to use the software listed below (collectively the "Software") on the respective number of computer nodes, terminal servers, or web servers, and/or for the respective number of client licenses, server sessions, or concurrent user licenses listed below. Unless explicitly approved by Wonderware Corporation in writing, all such use must be at the above designated location. Any and all use of the Software pursuant to this License Certificate is subject to the terms, conditions and limitations contained in the Wonderware Corporation License Agreement (the "Agreement"), a paper copy of which is enclosed with the software and an electronic copy of which is displayed in connection with the install program prior to the initial installation of the Software. Read the Agreement before installing or using any of the software, if you do not agree to the terms of the Agreement, promptly return the Software and this License Certificate within thirty (30) days of purchase to the place from which you obtained it for a full refund. By using the Software, you signify that you have read the Agreement and agree to be bound by its terms. Third party software included herein is licensed pursuant to license agreements displayed in connection with the install program a paper copy which is available upon request from Wonderware. Save this License Certificate. It represents proof of your legal license to run the below fisted software. Software: FSCAL2000 - Single License; Part: 17-0092; Version: FS2000 2 License(s) Software: FactorySuite Client Access License 2000 (FSCAL2000) Microsoft@ SQL Server 2000 Client Access License (Microsoft SQL Server2000CAL) restricted use License Mode: Per Seat Number of physical devices license applies to: I Software: FactorySuite Client Access License 2000 (FSCAL2000) Microsoft® SQL Server 2000 Client Access License (Microsoft SQL Server2000CAL) restricted use License Mode: Per Seat Number of physical devices license applies to: I Serial Number Hardware Key 746365-0 746366-0 Software: IndustrialSQL Server - 5,000 Tag; Part: 17-0134; Version: 8.0 1 License(s) Software: Microsoft® SQL Server version 7.0 or Software: Microsoft@ SQL Server version 2000 FactorySuite Client Access License 2000 (FSCAL2000) Microsoft@ SQL Server 2000 Client Access License (Microsoft SQL Server2000CAL) restricted use License Mode: Per Seat Number of physical devices license applies to: I Software: Microsoft® SQL Server version 7.0 or —"Software: Microsoft® SQL Server version 2000 FactorySuite Client Access License 2000 (FSCAL2000) Microsoft@ SQL Server 2000 Client Access License (Microsoft SQL Servef2000CAL) restricted use License Mode: Per Seat Number of physical devices license applies to: I Serial Number Hardware Kev 746363-0 Software: ActiveFactory Per Server; Part: 17-1009; Version: 8.5 1 License(s) Wonderware ActiveFactory License Installation Procedure Wonderware ActiveFactory License Installation Procedure Serial Number Hardware Key 746364-0 2 UPGRADES: The following applies to any or the above Licenses from an Upgrade programs: The above Wonderware Licenses are upgrades to your existing Wonderware licenses and not additional Licenses. You may choose to continue to use the existing Licenses, but if you do, you may not use these upgrade Licenses. You may not use the existing Licenses on one computer and the upgrade Licenses on a second computer. Page I of 1 _,.rd a—At!H 33y 33}2y[ -4."t1 W i:�— �� Wii.,3'$' �l�[F!4i�4►� tJ?.+� IS IT GENUINE? This document has a multi colored background, a teal colored Wonderware logo and a band of holographic silver foil. If you believe this certificate may be counterfeit. please email Wonderware at piracy@wonderware.com .. .. C .. ':... .. .. ... :.. Cr`.. .... .. .. .. .. .. .. .... : . . ........................ ... .. .. .. .. .. .. .. .. .. .. .. .. C.!? .5� �2 : w �s�►c arc�t:. : v .� �^'�''� . � ... ` .. ........ .. .. .. .. .. .. R. ... ... ... :. :. .. ...5 . Cd --Dfl J Cs t C .. .. .. .. 7..... :.........:.........:.........:........... ......................... ...:....................................... ....................................... .:....................................... :...................................................................... ....... tj .. .. ..... ...... .. :.. .. .. .. .. .................. ,. .. .. .. .. .. ....................................... :....................................... :....................................... :............................. .......... :.......................................:.......................... ............ . :.........:.........:............................................... :........ ............................... :............................................................................... :.......................................:........................... ............ Cell phone SCADAlarm! City of Renton SCADA Network Topology woo Home Computers Field/Home Laptops pcAnywhere Lj InTouch InTouch a Cell phone i SCADAlarm! Home Computers Field/Home Laptops pcAnywhere InTouch InTouch Public Works Workstation Public Works Workstation I Michael Benoit Water '& Wastewater SCADA Upgrade Page 1 From: J.D. Wilson To: Abdoul Gafour; David Christensen Date: 03/26/2004 2:20:38 PM Subject: Water & Wastewater SCADA Upgrade Abdoul / Dave: Here are the hardware and software costs for the Water & Wastewater SCADA upgrade (attached in As file). Water share: $15,620.00 - Wastewater share: $11,910.00 Please provide me with the fund cites and I will get these items on order. J.D. CC: John Thompson; Michael Benoit; Raymond Sled; Ronald Shaffer Item Dell PowerEdge 600SC Server including OS and Tapebackup software Dell Precision 630 WorkStation External modems MS Office XP Pro Industrial SQL ActiveFactory FactorySuite FSCAL2000 Miscellaneous Unit Cost Quantity SubTotal Tax Total Water Share Wastewater Share $7,221.47 1 $7,221.47 $635.49 $7,856.96 $3,928.48 $3,928.48 $1,750.77 2 $3,501.54 $308.14 $3,809.68 $3,809.68 $0.00 $121.99 4 $487.96 $42.94 $530.90 $265.45 $265.45 $460.00 1 $460.00 $40.48 $500.48 $500.48 $0.00 $10,795.00 1 $10,795.00 $949.96 $11,744.96 $5,872.48 $5,872.48 $1,095.00 1 $1,095.00 $96.36 $1,191.36 $595.68 $595.68 $495.00 2 $990.00 $87.12 $1,077.12 $538.56 $538.56 $200.00 1 $200.00 $17.60 $217.60 $108.80 $108.80 $26,929.06 $15,619.61 $11,309.45