Loading...
HomeMy WebLinkAboutWWP273473Statement of Qualifications & Proposal Summerwind/Stonegate Lift Station Consolidation and Field Avenue Interceptor City of Renton, Washington ck 46 December 2006 CNS ENGINEERS. LLC 12507 Bel -Red Road, Suite 101, Bellevue, Washington 98005-2500 I I L1 I F1 CHS ENGINEERS, LLC l 1 December 2006 David Christensen City of Renton Attn: SOQ/Proposal — Surrunerwind/Stonegate Lift Station Consolidation and Field Avenue Interceptor Design 6,h Floor Customer Sen-ice Center 1055 Grade Way Renton, WA 98055 Dear Mr. Christensen: CHS Engineers is pleased to submit our Statement of Qualifications and Proposal to the City of Renton for the Summerwind/Stonegate Lift Station Consolidation and Field Avenue Interceptor project. We are thoroughly committed to providing the City with excellence in predesign, planning, design and construction management. CHS will- ur most experienced and qualified staff for the City's project. The managing members of our firm are senior professionals whose careers have focused on municipal engineering. The majority of our clients are cities and special districts. We are familiar with municipal design standards and we understand the need to address your operational requirements and constraints. Our attached statement of qualifications will demonstrate that CHS's engineers, technicians, inspectors, surveyors and our subconsultant specialists have exceptional knowledge of lift station projects. In particular, we have completed predesign reports and designs and have prepared plans, specifications, bid documents and cost estimates for many similar sewer pump station projects. These predesign reports typically include evaluation of alternatives and preparation of preliminary cost estimates. Collectively, we have undertaken pre -design assessment of at st 65 sewer pump or lift stations. A summary tabulation of these stations is attac e m Section C fo owing. A majority of these projects w ere,.re-habilitation or replacement of e_,dsting stations. CHS also has in-depth experience in the planning, analysis, design, bidding and construction engineering of sewer main infrastructure including interceptors and gravity sewers. Recently, CHS has completed lift station and/or gravity sewer design projects for the cities of Arlington, Bellevue, Edmonds, Lake Stevens and Ivrkland and several special purpose districts, including Ronald Wastewater District, Olympic View Water and Sewer District, Birch Bay Water and Sewer District and Southwest Suburban Sewer District. In every project, we have worked directly with the client's engineering and operations staff to -collaboratively develop a scope of recommended improvements that best satisfies the community's needs and meets the operator's preferences. 12507 BEL-RED ROAD SUITE 101 BELLEVUE, WA 98005-2500 TEL (425) 637-3693 FAX (425) 637-3694 tWe have assembled a comprehensive and skilled team of professionals for this important project. ' CHS Primary Contact: CHS Alternative Contacts: I I fl 1 1 �I H Rodney Langer, P.E., Project Manager Scott Christensen, P.E., Principal -in -Charge Evan Henke, P.E., Project Engineer We have worked with our subconsultant team on many projects, including many lift station and other water and wastewater projects. Our subconsultant team includes: Richard Sample Engineering Electrical Engineering Key Personnel — Bob Casne, P.E. and Richard Sample, P.E. HWA GeoSciences Geotechnical Engineering Key Personnel — Ralph Boirum, P.E. and Erik Andersen, P.E. DCI Engineers Structural Engineering Key Personnel — Tom Xia, P.E., S.E. and Mark Moorleghen, P.E., S.E. We have organized our Statement of Qualifications and Proposal according to your RFQ: • Section A — Project Approach • Section B — Project Management • Section C — Project Team Members • Section D — References • Appendix — Resumes for Key Tearn Members CHS Engineers will provide the City of Renton with a comprehensive assessment that will result in a fully functional and useable project - on time and within budget. We look forward to hearing from you. Sincerely, CHS Engineers, LLC --Scott Christensen, E. President/Principal Rodney Langer, P.E. Project Manager/Principal CHS ENGINEERS, LLC D n I� i ' Section A iPROJECT APPROACH TASK No. 1 Pre -Design Report — Alternatives and Design Criteria RATIONALE: The goal of this task will be to prepare a document that will set forth all of the recommendations for the primary design elements. The completed report will ensure that both the City and CHS share the same understanding of the elements of the project prior to beginning the formal design. tACTION OUTLINE: �• Discussions with the City Engineering and Operations staff to identify flow 1 rates, desired features, emergency operations, telemetry requirements and / equipment compatibility with existing practices. V• Discussions with the City to identify the critical factors for evaluating pipeline alternatives (e.g.; cost vs. least disturbance, permitting issues, maintaining service, etc.) • An evaluation of the two or three most feasible discharge force main routing alternatives. �• An evaluation of the transmission (gravity) sewer main and applicable alternatives for increased capacity, including open cut replacement / extension and pipe bursting. • Summarize permit requirements. C: /• Participate in public meeting, present recommended design and discuss anticipated impacts and proposed mitigation with stake holders. TASK LEAD: Rodney Langer, P.E. TASK No. 2 Project Design and Bid Documents RATIONALE: The goal of this task will be to prepare the construction plan sheets, specifications and related contract documents into a comprehensive set that ' will be used to solicit and evaluate bids from prospective contractors. ACTION OUTLINE: • Lift Station site and pipeline survey (horizontal and vertical and existing utility research) will be performed to prepare base sheets of existing conditions. 1 • Lift Station site, structural and mechanical design. • Lift Station electrical design and coordination with mechanical features. • Plan and Profile design of discharge Force Main. • Plan and Profile design of gravity Sewer Main. • Temporary erosion and sediment control measures. t • Frequent review of CHS Lift Station Design Checklist and PreDesign Report to ensure that all elements have been addressed. • Submittals to the City at 50%, 90% and Final. • Preparation of Engineer's Estimate of construction cost. TASK LEAD: Rodney Langer, P.E. TASK No. 3 Project Bidding RATIONALE: The goal of this task will be to secure a competent and competitive contractor through the public bidding process. ACTION OUTLINE: • Prepare Advertisement For Bid. • Distribute Bid Packages. • Document and respond to contractor's questions. • Prepare and distribute Addendums (if any). • Attend Bid Opening. • Prepare and certify Bid Tabulation, research low bidder and issue Recommendation for Award. TASK LEAD: Rodney Langer, P.E. TASK No. 4 Construction Management RATIONALE: The goal of this task will be to ensure the timely, complete and successful construction of the lift station and pipelines ACTION OUTLINE: • Lead pre -construction conference. • • Review, route and approve shop drawings. Review and approval of phasing plan. • Construction staking. • Part time construction observation. • Documentation of pay quantities and progress. • Documentation of testing results. 1 • Monitor schedule compliance. • Coordination with impacted home owners. • Compilation of O&M Manual. Prepare drawings. • as -built • Project close out. TASK LEAD: Rodney Langer, P.E. t �1 I ij 1 1 I I RM CHS ENGINEERS, L L C City of Renton Summerwind / Stonegate Lift Station Preliminary Schedu e n'07 Feb'07 Mar'07 A r'07 Ma '07 Jun Jul Aug'07 Se '07 Oct'07 Nov' ID Task Name Duration 1/14 1/21 1/28 2/4 2/11 2/18 2/25 3/4 3/11 3/18 3/25 4/1 4/8 4/15 4/22 4/29 5/6 5/13 5/20 5/27 6/3 6/10 6117 6/24 7/1 7/8 7115 7/22 7/29 8/5 8/12 8/19 8/26 9/2 9/9 9/16 9/23 9/30 10/7 10/14 10/21 10/28 11/4 11/11 1 1. Pre -Design Station Style & OPR FM Alignment Service Phasing Gravity Sewer Alignment 2. Bid Documents Site(s) Survey & Topo 50% Design &Review Elect Coordination Structural Coordination 90% Design & Review Final P&S Engineers Estimate Permitting 3. Bidding Advertisement Questions Bid Opening Recommendation 4. Construction Management Contract NTP Shop Drawings Observation Startup Record Drawings 20 days 4 wks 7 days 2 days 8 days 76 days 2 wks 4 wks 1 wk 1 day 4 wks 2 wks 1 wk 3 wks 17 days 12 days 12 days 0 days 1 wk 93 days 3 days 0 days 1 wk 60 days 1 wk 2 wks a 1 �T ; ---=-=---- 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Project: LS Prelim Schedule Date: Mon 12/11/06 Task Split Progress Milestone Summary Rolled Up Split Rolled Up Progress ♦ Rolled Up Task Rolled Up Milestone «` External Tasks Project Summary Page 1 PRELIMINARY STAFF HOURS ESTIMATE Task PR PM I PE DS I CAD CL I Total 1. Pre -Design .......... ._............_....._......................- ......................& OPR 6..................... 12...... 18 ......... ........ 2StatonSt�le ....................... ......................... 2..................... 86 .... FM Alignment .--------...----....... -_... 1._ _._. _ 2 _............_ 4 -....__ 6 ._ .._._......_..._.8 _......... 0 21 ---.._.. -- -Phasing .. ....................- - - ..........._. -_._ ................ 4 ..._._..... �....................-1--- -.. 0 __ .._� .._ ......... ..... 24 Gravity.._Sewer Alignment....._... 1 .............._..............._....._._._........_..........._.._. 2 10 ................._8...... _ ..... ..........._.._-_..__ _........ 4 0 ........_......_......_..........__.._................ 25 Permitting__..-__.__..._.._.._. 0 2 0 6 0 0 8 Final Rem ----_.....____......___. �....._ 6 12 3 8 8 39 - - -........._Public Meeting .. ................._....--- .. ._.._..._�.....- 4_ ....__._..... 4 ----- -0 --- 4- -...._.._ _- _. ........_.._............----._...- ---------........_........_......__._ 2. Design & Bid Documents ._._......... ... .......... ._.._.._.__....... .._.............. . ------..... ................ .... _...... _........ ---.............. _. SiteD-Survey & To - --- . - 0 -. ........ 0 __.............. _... 0 --- 16 _...-- ....._............_.._.... 0 -- -- - .... ... - - 0 -- -- - - 16 -- ---- ......................._50%Design ......_.__._....._......... _. _ ._ .__..._..._12....................78_..............._32._......._......_84 96 ........ 24- ._........_326 Elect. Coordination 0 4 6 4 0 0 14 ---............ --.._.__..__ ._........__ 90% Design & Review - ----..... --- . 16 ._.....-._..- -52 --- - 16 --- 44 - ....._.. - 48 -- 12 -- - - - .. 188 -..... _...... Final Plans & Specs ...................... _........ .................-_-...................._._._...__ ........._...._.6 16 6 20 ..._......._..................._.._..----....._.............__...._._. 24 6 78 _.._._...................... -Engineer's Estimate . 4 .._....._..__.............-_._.. 21 40 _. _._....._._ 0 .-_.._....._......._...__...._......_._....__..._ 0 0 65 _...................__.. Permitting 0 18 40 0 24 6 88 ---.......... _................................ _...................... ............... ..._..__.._.................. 3. Bidding ._. _._ . __. _ . Advertisement 0 1 2 4 0 ....... .... -- Questions ........... . -- -----....................... _ .........................._..._Bid._OPe''.g..............................................._.._......._..............._�...... 1 ................_. ..........__....._�_.._..._........._�.._................_.._�.................._......_3.... Recommendation 1 2 0 4 0 0 7 ................. _....... _...__.._ ............ --- ... _........... - --.. - 4. Construction Management -- - _.......................... .............-----.._....................._ --._.._... _.._ ... _.............._.._.. ....... -- ......... _.-..._.__.. --- ........... _..... -- ----..._. Preconstruction Conference 0 4 4 4 0 0 12 -- - .._.. - -----Shop Drawings--.............._..__.....---..._.0...........-12--._ _.._.._... ......-- .................._....- 60.._.........._20 - - - --- 0 ..............._...-- ---0 ..... - ........ _ 92 --..._Progress Meetings......_......_........_.............._..........._0......_......__i_6�...... 6 0 .... _._......................._. Inspection-_..._.__._...___.-_.._.__..__0..... 8 16 160 0 0 184 _..._............_Pay Estimates ._....._................- --.....__..._ - 0 6 - 24 0 -._.._....- 0 0 -- 30 - - ----- ..................................._Record Drawings ............... _........_....._..._..... .... _..........._�.._.-.._._..._.. ............... 1 - --- -� ..._._...._20.._......._... __34... O&M Manuals 1 6 24 0 12 8 51 Totals 52 281 346 441 264 66 1450 Note: The man hour estimate does not include the services provided by sub -consultants or the survey. Staff Key: PR - Principal -in -Charge PM - Project Manager PE - Project Engineer DS - Design Engineer CAD - CAD Technician CL - Clerical Staff m E7 n F', L Section B PROJECT MANAGEMENT Project Management Methodology. CHS utilizes proven and effective management methods in executing all projects which includes the fundamental elements of planning, staging resources, directing tasks, monitoring progress and concluding the work. Of particular importance is the planning phase during which the details of the project scope and schedule are developed. A well -planned project can be accomplished efficiently, on schedule and without unnecessary or additional cost. Of key importance is a well -developed scope of work, prepared to meet the project objectives and structured with some flexibility to adapt to aspects of the project that may require variable level of effort. As a modest sized firm, CHS is able to easily react and respond to unexpected issues or other direction from the City. Cost Tracking Methodology: The CHS Project Manager is responsible for monitoring the project progress and costs while the Principal -in -Charge will also track the project status. An important relationship between schedule and cost control is that "time is money" for both CHS and the City. CHS recognizes the importance of meeting project deadlines thus minimizing project costs caused by scope - creep and cost escalation. Managing Subconsultants: CHS is adept at working with other professionals and firms as subconsultants, both large and small. The CHS Project Manager will be responsible for managing the subconsultants and will assure that the key personnel named for the team will be utilized for the actual project assignments. Subconsultants are an extension of the CHS engineering staff and generally have the same level of interaction and participation as CHS employees. Geotechnical Engineering Ralph Boirum ' L:rik Andersen HWA ORGANIZATIONAL CHART CITY OF RENTON Dave Christensen Rodney Langer Scott Christensen Project Manager QA/QC CHS CHS Project Engineer Evan Henke CHS Electrical Structural Engineering Engineering Bob Casne I Tom Xia I Rich Sample Mark Moorleghen RSE DCI 1 0 �l r Section C ' 1 FIRM PROFILE AND KEY PROJECT STAFF For 14 years CHS Engineers, LLC (CHS) has specialized in providing engineering services ' for public agencies, particularly municipalities and special purpose districts. Our offices are located in Bellevue, Washington and we serve clients throughout the Puget Sound and Central Washington regions. Our staff of 24 civil engineers, land surveyors, and technicians ' has extensive experience in working with the unique engineering and construction project needs that challenge agencies on a regular basis. We also strive to be proactive and current on new construction methods and materials. CHS Engineers, LLC (CHS) has a core group of engineers who specialize in and have extensive knowledge of wastewater transmission and treatment. We have in-depth ' experience in the planning, analysis, design, bidding and construction engineering of sewer main infrastructure and pump stations. CHS currently provides engineering services for sewer system design and/or review for Ronald Wastewater District, Southwest Suburban Sewer District, Birch Bay Water and Sewer District, Skagit County Sewer District No. 2, Woodinville Water District, Olympic View Water and Sewer District and the Cities of ' Arlington, Bellevue, Blaine, Carnation, Edmonds, Everett, La Conner, and Lake Stevens. Scott Christensen, CHS Principal -in -Charge for the Renton Lift Station and Interceptor Project, has managed, planned, designed and provided construction engineering for many sewerage facilities, including wastewater treatment plants, lift stations, force mains, gravity sewers and related facilities for a number of municipalities and special purpose districts for more than 30 years. He has performed lift station evaluation and design, including analysis of erosion and settlement, inadequate hydraulic sizing, updating equipment, corrosion protection, inadequate ventilation, noise abatement, electrical control problems and the addition of emergency generators. Lift stations Scott has designed include submersible, wet well/dry well, duplex grinder, renovation of existing stations, in -plant pumping systems, and grinder pump systems. Rodney Langer, CHS Project Manager for the Renton Lift Station and Interceptor Project, has over 17 years' experience in planning, design and construction observation of water and ' sewer facilities. He has worked with all components of municipal water and sewer systems, including comprehensive and facility plans, wells and booster stations, storage facilities, transmission/distribution mains, pump and lift stations and collector and interceptor systems. Several projects have involved the expansion or rehabilitation of existing facilities or installation of new pipeline in utility -crowded public right-of-way. Rodney is very capable in the preparation of engineering reports, cost estimates, plans, specifications and contract ' documents. His communication skills and organized project approach assure the client that the project is addressed in an efficient and complete manner. ' Evan Henke, CHS Project Engineer for the Renton Lift Station and Interceptor Project, has over 15 years' experience, including the planning, design, project management and construction observation of water, sewer, storm water drainage and site development ' projects. In addition, Evan has experience in construction management and materials quality control. Evan is skilled in the preparation of plans, specifications, cost estimates, assessments and computer modeling. Wastewater Pump/Lift Stations Experience 11 Station Name Owner Year Capactty Mr. Type Genaet Rehab New Scott Rodney Evan RSE PS No. 3 Rehab BBWSD 2005 2,300 Custom Submersible X X X X LS No 2 Rehab SCSD#2 2005 310 Myers WW Mtd. X X X LS No. 7 Rehab SCSD#2 2005 450 Myers WW Mtd. X X X Forest Glen PS OVWSD 2005 290Custom WW/DW X X X X X LS No. 7 Rehab SWSSD 2005 Custom Submersible X X LS No. 2 COLS 2004 700 Smith & Loveless WW/DW X X X X X LS No. 8 COLS 2004 600 1 Smith & Loveless WW/DW X X X X X LS No. 12 COB 2004 750 Custom WW/DW X X X Sunrise LS WWD 2004 300 Custom Submersible X X X X Baalev PS Odor COB 2004 n/a Custom WW/DW X X X Good Samaritan LS Sammamis 2003 50 Package Grinder X X LS No. 1 RWD 2002 250 Smith & Loveless WW/DW X X X X X LS No. 2 RWD 2002 200 Smith & Loveless WW/DW X X X X LS No. 3 RWD 2002 40 Smith & Loveless Ejector X X X X LS No. 5 RWD 2002 600 Smith & Loveless WW/DW X X X X X LS No. 7 RWD 2002 50 1 Smith & Loveless Ejector X X X X BP Refinery PS BBWSD 2002 153 Custom Submersible X X RAS PS P BBWSD 2002 700 Custom WW/DW X X X X PS No.16 LFP 2002 100 Custom WW/DW X X PS No.17 LFP 2002 100 Custom WW/DW X X LSNo. 1 COB 1999 425 Custom WW/DW X X X X LSNo. 2 COB 1999 300 Custom WW/DW X X X X X FS No. 9 COB 1999 375 Custom Dry Well X X X X X FS No. 10 COB 1999 375 Custom Dry Well X X X X X LS No. 4 RWD 19991 250 1 Smith & Loveless WW/DW X X X X X LS No. 6 RWD 1999 125 Custom WW/DW X X X X LS No. 11 RWD 1 1999 137 Usemoo WW/DW X X X X RAS PS WWTP LAC 1999 250 Custom Above Gr. X X Influent PS WWTP LAC 1999 970 Custom WW/DW X X X X LS No. 1 COLS 1998 705 Smith & Loveless WW/DW X X X X X LS LIHI 1998 125 Custom Submersible X X X LS LIHI 1998 125 Custom Submersible X X X Emergency RWD 1997 2,100 Custom Submersible X X X Blaine Road PS BBWSD 1997 450 Custom Submersible X X X X X Pleasure Point PS COB 1997 300 Custom WW/DW X X X X LS No. 13 RWD 1996 500 Smith & Loveless WW/DW X X X X X X Cozy Cove PS Blower COB 1996 n/a Custom WW/DW X X X PS No. 8 SWSSD 1995 1,500 Custom WW/DW X Lake Hills No. 16 PS COB 1995 400 Smith & Loveless WW/DW X X X X X Midlakes PS COB 1995 800 Smith & Loveless WW/DW X X X X X X Palisades PS COB 1995 165 Smith & Loveless JWWIDW X X X X X Bagley PS COB 19951 300 Custom WW/DW X X X X Killarney PS COB 1995 350 Custom WW/DW X X X X Me denbauerPS COB - 1995 300 Custom WW/DW X X X X Loomis Trail PS BBWSD 1993 450 Custom Submersible X X X X X LS No. 12 RWD 1992 400 Custom WW/DW X X X X LS No. 8 RWD 1990 100 Smith & Loveless WW/DW X X X Lake Hills 94 COB 1990 400 Custom WW/DW X X Newport Lift Genset COB 1990 n/a X X X Trails West LS Arizona 1989 500 Custom Submersible X X PS No. 3 Upgrade BBWSD 1988 1,800 Custom Submersible X X Phantom Lake PS No. 6 COB 1988 180 Custom Submersible X X Phantom Lake PS No. 7 COB 1 1988 230 Custom Submersible X X Cozy Cove PS COB 1988 350 Custom WW/DW X X Fairweather PS COB 1988 350 Custom WW/DW X X Newport Lift Station COB 1988 325 Custom WW/DW X X Newport PumStation COB 1988 700 Custom WW/DW X X LS No. 9 RWD 1987 95 1 Smith & Loveless WW/DW X X X Skagit Sdwa WCWD12 19851 100 H dromatic Submersible X X LS No. 9 SCSD#2 19821 47 H dromatic Grinder X X PS No. 1 SCSD#2 19801 430 Smith & Loveless WW/DW X X LS No. 2 SCSD#2 19801 240 Smith & Loveless WW Mtd. X X LS No. 3 SCSD#2 19801 225 Smith & Loveless WW Mtd. X X LS No. 4 SCSD#2 1980 120 Smith & Loveless WW Mtd. X X LS No. 5 SCSD#2 1980 20 Smith & Loveless WW Mid. X X LS No. 6 SCSD#2 1980 150 Smith & Loveless WW MIA. X X LS No. 7 SCSD#2 1980 270 Smith & Loveless JWW Mtd. X X LS No. 8 SCSD#2 1980 & Loveless WW Mtd. X X �265Smith Evaluation Reports RWD 2005 Predesi n report for rehabilitation of lift stations #14 and #15. City of Edmonds 2003 Evaluated 14 wastewater IhVpump stations and developed dviUmechanicaUelectircal rehabilitation cost estimates City of Bellevue 1992 Evaluated 8 wastewater lift/pumpIffUpump stations and developed civil/mechanicaUelectircal rehabilitation cost estimates City of Bellevue 1986 Evaluated 25 wastewater IhVpump stations and developed dviUmechanicaUelectircal rehabilitation cost estimates SWSSD 2002 Evaluated 7 wastewater lifUpump stations with respect to seismic hazard vulnerability. City of Kirkland Evaluated standby r needs for 5 wastewater lift/pumplift/pump stations. OVWSD 2005 Evaluated ejectors a wastewater station for replacement with submersible, for PVJTF application scope/cost development C' of Bellevue 1987 Develo Municipal PUMP Station Standards Key Scott = Scott Christensen, Rodney = Rodne Lan er, Evan = Evan Henke, RSE = Richard Sam le Engineering LS = Lift Station, PS = PumpStation, FS =Flush Station COB = City of Bellevue, RWD = Ronald Wastewater District, COLS = City of Lake Stevens, SWSSD = Southwest Suburban Sewer District, BBWSD = Birch Bay Water and Sewer District, LAC = Town of LaConner, OVWSD = Olympic View Water and Sewer District, W WD = Woodinville Water District SCSD#2 = Skagit County Sewer District No. 2 LFP = Lake Forest Park COK = City of Kirkland LIHI - Low Income Housing Institute PROJECT BRIEF 11 I 1-1 I Pump Station #3 Rehabilitation Birch Bay Water & Sewer District The rehabilitation of the 2300 gpm Pump Station #3 involved the complete replacement of the electrical system including adding variable frequency drive (VFD) for 110 hp submersible pumps. The VFD was incorporated to minimize surges to the wastewater treatment plant and to reduce energy costs. Telemetry, motor controls and a standby generator were raised from a below -grade vault to a new above -grade masonry building. A detailed bypass specification was also prepared to bypass flows during construction. Mitigation for placement of a new above -ground facility in a residential shoreline area included private street improvements, stream buffer enhancements, and noise attenuation features. Dates: Design in 2005, Construction in 2006. Contractor: Strider Construction, Bellingham, WA CHS Staff: Rodney Langer, P.E., Project Manager Eli Zehner, P.E., Project Engineer Owner/Client: Birch Bay Water & Sewer District Dan Eisses, P.E. (360) 371-7100 CHS ENWME" LLC PROJECT BRIEF J Lift Station #8 Improvements City of Lake Stevens Following identification of future capacity needs in the northeastern part of the City, including the partially developed industrial area, force main and lift station improvements were completed for this facility. Lift Station #8 was initially constructed with over -sized wet well and dry well to accommodate future expansion, and discharged 200 gpm through a four -inch force main to the sewer basin tributary to the City's overloaded Lift Station #1. This project included completion of a 10-inch diameter force main, which terminated in a temporary 8-inch extension to an interim point of discharge (a future downstream interceptor is planned for the ultimate upgrade of this station). Pump assemblies and electrical equipment, including replacement of the standby generator set, were upgraded to accommodate 600 gpm. The pumps and force main sizing and electrical system upgrades were designed to provide for a future upgrade to ultimate capacity of 1,200 gpm. A magnetic flow meter was installed on the force main at the station for data collection for future system planning. The interim upgrade allowed completion of other collection system modifications to transfer portions of the area served by Lift Station #1 to Lift Station #8, further reducing the load on Lift Station #1. CHS provided pre -design, design and construction support services, and prepared a successful application for Washington State Public Works Trust Fund low -interest loan for this project. CHS Staff: Rodney Langer, P.E., Project Principal and Manager Owner/Client: City of Lake Stevens, Jan Berg, Finance Director (425) 377-3230 Construction: SRV Construction, Oak Harbor (Lift Station) and B&L Utility, Snohomish (Force Main) Date: Planning and Design, 2002/2003 - Construction, 2003/2004 CHS-Ar4NEERS, Li 11 PROJECT BRIEF Sewer Lift Stations No. 1, 2, 3, 5 and 7 Rehabilitation Ronald Wastewater District, Shoreline, Washington This project resulted in the rehabilitation of five wastewater lift stations that were each approximately 30 years old. The project began with evaluation of each station and development of a predesign report. The findings and estimates in the predesign study supported preparation of a successful application for a low -interest Public Works Trust Fund loan. CHS completed the predesign report and loan application, then prepared contract and construction documents and provided construction management services for the District. Lift stations ranged in size from approximately 100 gpm to 725 gpm. Stations 1, 2 and 5 were wet well/dry well type and Stations 3 and 7 were compressor type. All stations were analyzed to ensure proper capacity was available for the drainage basin they served. The pumps, compressors, valves, electrical systems and telemetry were replaced on all stations. Ventilation and safety platforms were updated to meet current standards. To preserve the steel dry well structure at Lift Stations 1, 2, 3, 5 and 7 an active cathodic protection system was designed and installed at each station. The project was successful in lowering required maintenance and increasing the life of the stations by at least another 30 years. CHS Staff: Scott Christensen, P.E., Project Principal Rodney Langer, P.E., Project Manager/Engineer Owner/Client: Ronald Wastewater District Michael Derrick, General Manager 206-546-2494 Construction: Prospect Construction, Pacific, WA Date: Planning, Design, Construction, PWTF Administration 2000-2003 CHSEWSIMfRS, a PROJECT BRIEF Sunrise Lift Station Woodinville Water District This project involved the replacement of an undersized wet well — dry well pump station with a caisson con- structed submersible pump station rated for 300 gpm @ 80 TDH. The caisson design eliminated shoring issues on the narrow construction site. The project included a self -draining storage well to respond to power outages and also provided for convenient controls. Other improvements included the addition of wet well ventilation, emergency power switching, and pump diversion piping. The station was designed for minimal maintenance requirements. Sewer service was successfully maintained throughout construction. Dates: Design in 2003, Construction in 2004. Construction: Omega Contractors, Duvall, WA CHS Staff: Evan Henke, P.E., Project Manager Owner/Client: Woodinville Water District Ken McDowell, P.E., (425) 487-4104 CHS ENGINEERS. UC SUBCONSULTANTS ' Richard Sample Engineering (RSE) — Electrical Engineering RSE has provided electrical engineering services as a sub -consultant on over 75 new or ' extensively renovated sewer or water pump stations. All projects involved complete design, bid and construction support services as required for either complete new lift stations or major renovations to existing lift stations. The following is a partial list of relevant projects: I• City of Bellevue — 20 lift stations, 7 flush stations, 1 booster pump station • City of Issaquah — 2 lift stations • City of Lake Stevens — 3 lift stations • Cedar River Sewer District — 2 lift stations • Eastgate Sewer District (now City of Bellevue) — 3 lift stations, 2 flush stations • Ronald Wastewater District — 6 lift stations HWA GeoSciences (HWA) — Geotechnical Engineering HWA specializes in geotechnical engineering, hydrogeology, geoenvirontnental services, and construction inspection and materials testing services. Typical services for sewer facilities ' include subsurface explorations, engineering analyses and recommendations pertaining to excavation and shoring, dewatering, foundation design, and pipe bedding and backfill. HWA has also worked on more than 40 pump/lift stations for various local agencies ' including Strander Boulevard Pump Station for the City of Tukwila; Lift Stations 7 and 8 Upgrades for the City of Edmonds; Lift Station No. 2 for Northshore Utility District; Lift Station 3 for the NE Sammammish Sewer & Water District; and North Creek, Sweyolocken, Kenmore and Lakeland Hills pump stations for King County. In addition, HWA has worked on numerous pipeline projects and has considerable experience with trenchless technologies such as pipe jacking, microtunneling, and directional drilling. Notable projects ' include the NE Sunset Boulevard Interceptor Phase III for the City of Renton; Perrinville Water Replacement for the City of Edmonds; Lift Station 10 Bypass and Sewer Main D Replacement projects for the City of Everett; and the North Creek Diversion Project, Denny Way/Lake Union CSO, South Lake Union Pipelines, Elliott West Pipelines, Eastside Interceptor Restoration and Swamp Creek Trunk Sewer Extension for King County. DCI Engineers (DCI) — Structural Engineering DCI provides civil and structural engineering services on new and remodel governmental, residential, medical, industrial, educational, and commercial projects. Our staff members' experience and expertise enables the firm to produce economical designs — without compromising quality. Some of DCI's relevant project experience includes: ' • Sunrise Lift Station — Wet/Dry Well Structure, Woodinville, Washington Birch Bay Wastewater Treatment Plant Improvements, Birch Bay, Washington, Birch Bay Water and Sewer District • La Conner Wastewater Treatment Plant, La Conner, Washington • Miller Creek Wastewater Treatment Plant — Grit Chamber Replacement, Des Moines, Washington • Grand Ridge Pump Station, Issaquah, Washington An r 1 Section D REFERENCES Firm Performance On Similar Projects Mr. Michael Derrick General Manager Ronald Wastewater District 206-546-2494 2005 15th Ave Sewer Rehabilitation ' 2003 Lift Stations 1, 2, 3, 5 & Improvements 1999 Lift Stations 4, 6 & 11 Rehab 1997 Shoreline Washout Emergency ' Bypass Sewer Pump Station 1995 Lift Station #13 Replacement Mr. Paul Richart, P.E. Senior Engineer City of Arlington 360-403-3512 ' 2004 67th Ave NE Compost Facility Offsite Sewers & Sewer Force Main 2002 59th Drive NE Sewer Phase II ' 2001 59th Drive NE Sewer Phase I 1997 Sewer Outfall Repair Mr. David Voigt, P.E. Senior Engineer Cityty of Everett 425-257-8983 2005 Northend Basement Flood Reduction Sewer Replacements 2004 Sewer Replacements Schedule "A" 2004 Sewer Replacements Schedules "B" & "C" 2003 Combined Sewer Replacement Schedule "E" Mr. Ken McDowell, P.E. Engineering Services Supervisor Woodinville Water District 425-487-4104 2004 Sunrise Lift Station 2001 Northshore Pump Station #16 Bypass 2000 NE 145th St Sewer Upgrade 2000 Redhook Brewery Sewer Project Manager's Performance On Similar Projects ' Mr. Dan Eisses, P.E. Engineering Services Mana er Birch Bay Water and Sewer istrict 360-371-7100 1 1 2006 Pump Station #3 Rehabilitation 2006 Birch Bay View Community Sewer 2000 Wastewater Treatment Plant Improvements 1997 Blaine Road Pump Station 1994 Loomis Trail Pump Station Mr. Don Fiene, P.E. Assistant City Engineer City of Edmonds 426-771-0220 2004 SR104 Sewer Main Rehab 2004 Daley Street Pipebursting 2003 Admiral Way Sewer Rehab 2000 2000 Perrinville Sewer LID 215 & 216 Ms. Jan Berg Finance Director City of Lake Stevens 425-377-3230 2004 Lift Station #8 & #2 Improvements 2004 Grade Road Sewer Main/Lift Station 7 Elimination 2002 Sewer Capital Improvements 1997 Lift Station #1 Improvements and Force Main Replacement Mr. Roger Eberhart, P.E. General Manager Olympic View Water & Sewer District 42-774-7769 2005 Forest Glen Lift Station Rehab 2004 Westgate Lift Station Predesign 2000 Sherwood Forest Sewer Rehab RESUMES m �� m m m m m m am m m m m m M40M SCOTT CHRISTENSEN, P.E., PRINCIPAL ' EDUCATION B.S., Civil Engineering University of Washington A.A.S. Civil Engineering Technology Green River College REGISTRATION Professional Engineer: Civil Washington 1977 Alaska 1981 Scott has managed, planned, designed and provided construction engineering support for public works projects in water, storm water and sewerage facilities, including wastewater ' treatment plants, pump stations, force mains, gravity sewers, water mains, reservoirs, detention systems and related facilities for a number of municipalities and special purpose districts for more than 30 years. He has performed pump station evaluation and design, including analysis of erosion and settlement, inadequate hydraulic sizing, updating equipment, corrosion protection, inadequate ventilation, noise abatement, electrical control problems and the addition of emergency generators. Sewage pump stations Scott has engineered include submersible, wet well/dry well, duplex grinder, renovation of existing stations, in -plant pumping systems, and grinder pump systems. Scott has provided design and construction engineering for water transmission and distribution lines, major pipelines, water supply pump stations, constant pressure pump systems, fire pump systems, well pumps, pressure reducing valve stations, reservoirs and other related facilities. I Representative Project Experience Project Principal Water Supply Improvements —161" Avenue Pump and Flow Control Station City of Bellevue Bellevue, Washington Provided construction services for this new water pumping and flow control station that will become part of the City of Bellevue system. This fully -automatic station is part of a new sub -regional water conveyance system that transfers water from Seattle Public Utility t through Bellevue and eventually to Issaquah. Mechanical equipment includes two variable - speed high -efficiency pumps rated at 5 mgd each and a motor -operated butterfly control valve. The building is mostly underground, with aesthetic site improvements, state-of-the- art controls and telemetry and two standby emergency power generators. CHS also prepared as -built drawings and O&M manuals. Project Principal —Water Supply Improvements — Holly Street No. 2 Pump Station Port Blakely Communities Issaquah, Washington t Part of the City of Issaquah water system, this facility receives water from either wells or from Bellevue and working in tandem with an existing pump station (Holly Street No. 1), CHSENGINEERS. LLC 11 ' Scott Christensen, P.E. Page 2 fills a water reservoir at the 742 zone elevation in Issaquah Highlands. Major mechanical equipment includes three vertical turbine pumps rated at 1,000 gpm, 200 horsepower each ' and surge suppression tanks on both suction and discharge piping. The project also included a 350kw trailer -mounted generator. ' Project Principal — Sewer Pump Station No. 12 Pump Replacement and Odor Abatement City of Bellevue ' Bellevue, Washington Provided predesign, design and construction management services to replace two existing sewage pumps that were inefficient and unreliable due to hydraulic problems and outdated electrical equipment. The construction involved replacing two existing 125 HP single -stage pumps with four new high -efficiency 50 HP variable speed pumps in two -stage arrangements. Rated for 750 gpm at 120 psi, the new pumps provide significantly lower ' operating power cost. Because this pump station is very close to homes, a carbon canister odor scrubber with ducts, fan and appurtenances was installed to control odors. In addition, special pump control valves were installed to solve a chronic check valve clogging problem. Project Principal - Biofilter For Odor Abatement At Bagley Sewer Pump Station ' City of Bellevue Bellevue, Washington Based on a detailed evaluation of numerous alternatives for odor control, a mineral media, in -ground biofilter was selected for this facility. Because of the close proximity to nearby Lake Washington residences (approximately 40 feet away) and the propensity (history) of the pump station to emit sewage odors, a reliable odor control technology had to be ' implemented. Furthermore, placing new equipment and structures underground to mitigate visual impacts and noise preserved the aesthetic character of the site (residential waterfront at Newcastle Beach Park). A 3-HP variable speed fan in an underground vault draws odorous air from the pump station wet well and conveys it to the biofilter bed where it is dispersed through perforated pipes and purified by microorganisms in the sand media. The biofilter system is equipped with instrumentation and devices to monitor and control sand moisture and to measure air flow and backpressure. The biofilter operates automatically without the need for frequent maintenance, inspections or chemical deliveries. ' Project Principal — Sewer Lift Stations No. 4, 6 and 11 Rehabilitation Ronald Wastewater District Shoreline, Washington ' This project resulted in the rehabilitation of three wastewater lift stations that were each approximately 30 yeas old. The project began with evaluation of each station and development of a predesign report. The findings and estimates in the predesign study ' supported preparation of a successful application for a low -interest Public Works Trust Fund loan. CHS Engineers completed the predesign report and loan application, then prepared contract and construction documents and provided construction management services for the District. The work at Lift Station No. 4 included replacement pumps and confined space ventilation equipment, replacement electrical service equipment and addition ' Miffl CHS ENGINEERS, L L C Scott Christensen, P.E. Page 3 ' of a 50 kW standby power diesel generator set in an underground vault. Lift Station No. 6, situated in an eight -foot inside dimension cube, was converted from an ejector type system to a wet well/dry well station. This work was accomplished within the existing concrete structure. Lift Station No. 11 was also an ejector type station but in a buried steel structure. The station was ultimately replaced entirely with a new wet well -dry well station installed ' nearby. Project Principal — Ronald Emergency Bypass Sewer Pump Station ' Ronald Wastewater District Sborrline, Washington Fast -track design and construction engineering of a 3,300 gpm sewer pump station and 650 feet of 12— and 16-inch diameter polyethylene force main to bypass the 175th and 6th Avenue Shoreline "Washout". The station was designed and constructed in 20 days. The "washout" occurred in the late evening of December 31, 1996, and pump station was up and ' running on morning of January 20, 1997. Project Principal — Sewer Pump Station No. 8 Upgrade ' Southwest Suburban Sewer District Federal Way, Washington Directed engineering team which completed design, specifications and construction oversight for replacement of pumps, motors and controls for an existing large -capacity sewer pump station. Two 100 HP pumps and two 65 HP pumps rated for 2,500 gpm replaced three old pumps. Outdated electrical systems, lighting, water supply and plumbing systems were all ' replaced. Seismic bracing and joint restraint was added to mechanical piping and equipment. Because of the large variation in flow at the station, two discharge force mains were also installed. The new 16" and 10" force mains can handle a wide range of flows from any ' combination of the four pumps operating. The station also has an existing 10" inverted siphon passing through it which was reconnected to the new discharge force mains ' Project Principal — Horizon View Pump Station #3 Water Main Replacement City of Bellevue Bellevue, Washington This project was expedited because some existing buried DI pipes were developing leaks due to corrosion. CHS provided design and construction inspection services for work that required a precise construction sequence so that water service to thousands of customers was not interrupted. A specialized line -stopping procedure using cryogenic freezing methods was done successfully to install a new 12-inch isolation valve on a 32 million gallon reservoir supply pipe. A new vault with control valves and about 200 LF of new DIP was ' also installed. These improvements maximized operating flexibility and will enable a total replacement/rehabilitation of the pump station at a future time with minimum and risk and impact to water customers. CHS ENGINEERS, LLC IPump Station Listing City of Bellevue — 40 S , 5 M 45 Ronald Wastewater District — 14 S , UP 2 PS S 16 Olympic View Water and Sewer District — 1 2 S 3 Birch Bay Water and Sewer District — 4 , 8(S) 12 Port Blakely — 3 M, 2 SS 5 City of Issaquah, 1 S 1 City of Blaine — 3 S 3 Skagit County Sewer District #2 — 6 S 6 Town of La Conner — 2 S , 2 SS 4 City of Burlington — 1 (SS) 1 City of Edmonds —14 S , 1 15 Coal Creek Utility District — 3 3 City of Auburn — 1 2 3 Town of Forks — 1 1 Glacier — 1 1 City of Wrangell —1 (W) 1 (S) City of Bethel — 1 , 1 S 2 2 Whatcom County Water District No. 12 — 1 S 1 Shelter Bay Community —1 S , 1 2 City of Kirkland — 5 S 5 Total 130± Scott Christensen, P.E. Page 4 CHS ENGINEERS. 1[C I, u RODNEY C. LANGER, P.E., PROJECT MANAGER EDUCATION B.S., Civil Engineering University of Arizona Graduate Certificate, Project Management City University PROFESSIONAL REGISTRATION Professional Engineer: Civil Washington California PROFESSIONAL EXPERIENCE Rodney Langer has 17 years' experience in planning, design and construction observation of water and sewer facilities. In particular, Rodney has extensive experience in evaluation and design of municipal wastewater pump stations including new facilities or rehabilitation of existing stations. He has worked on over 30 lift station projects. These evaluation, pre - design, design and construction support services have included consideration of flows from 100 gpm to 3,300 gpm, various station configurations including wet well/dry well, submersible, and wet well mounted, a wide range of control systems and level sensing devices and provision for onsite or portable standby power equipment. Additionally Rodney has worked with all components of municipal water and sewer systems, including comprehensive and facility plans, wells and booster stations, storage facilities, transmission/distribution mains, pump and lift stations and collector and interceptor systems. Several projects have involved the expansion or rehabilitation of existing facilities or installation of new pipeline in utility -crowded public right-of-way. Rodney is very capable in the preparation of engineering reports, cost estimates, plans, specifications and contract documents. Rodney has led or participated in several public meetings and presentations to public officials. His communication skills and organized project approach assure the client that the project is addressed in an efficient and complete manner. Rodney has worked with special purpose districts and cities in western Washington for 15 years. Representative Project Experience Project Manager - Pump Station No. 3 Rehabilitation Birch Bay Water and Sewer District Birch Bay, Washington Rodney was the project manager for this successful rehabilitation of the primary station in ' the District's system. The project team completed predesign and design services and supportted construction management. Pump Station #3 is the main station in the system, effectively acting as the WWTP influent pump station. This submersible pump station was upgraded from 2.5 mgd capacity to 3.3 mgd capacity. A subsequent force main replacement project may allow future increase to 4.4 mgd capacity. The electrical equipment including standby power generator was replaced to include variable frequency drives for power savings and reduced peak loading at the WW'fP, and all electrical equipment was relocated from an underground vault to an at -grade equipment building. The station is located on a narrow CMS EAVNEM, L L C H Rodney Langer, P.E. Page 2 spit between a tidally influenced salmon stream and Birch Bay. Permitting necessary for this project included zoning and shoreline conditional use approval and shoreline setback variance. Wastewater flow bypassing of up to 3 mgd capacity was necessary for portions of this work and CHS has prepared a detailed specification for the equipment and redundancy requirements for this risky operation. Project Manager - Lift Stations 2 and 7 Replacement Skagit County Sewer District #2 Big Lake, Washington Completed predesign and design services and supported construction for the replacement of these two stations. The existing stations were vacuum -prime solids handling wet well mounted type stations, constructed in 1980 on the shoreline of Big Lake. Operation and maintenance of the vacuum -prime systems is labor-intensive and costly. Rodney compared the benefits and feasibility of converting each station (300 to 400 gpm capacity) to submersible pumps or wet well mounted self -priming solids handling pumps. Primary considerations in this evaluation were the visual and noise impacts to adjacent lakefront properties and ease of maintenance for the District operator. The District selected the self - priming units. Rehabilitation consisted of a complete factory -built package of mechanical and electrical equipment, all contained within an enclosure. ' Project Manager - Forest Glen Lift Station Upgrade Olympic View Water and Sewer District Edmonds, Washington ' Rodney was the Project Manager for the upgrade of a 37-year old wastewater pump station and force main. A pre -design report, plans, specifications and cost estimate were prepared for modifications included increased capacity pumps (up to 290 gpm) and other ' improvements. The project included addition of an onsite diesel standby generator in an underground vault and replacement pumps, piping, valves, ventilation system and access hatches. Services included construction management services such as shop drawing and pay ' estimate review, construction observation and operation and maintenance manual preparation. ' Project Manager — Lift Stations No. 2 and 8 Improvements City of Lake Stevens Lake Stevens, Washington ' Project Manager for design and construction support services to increase capacity at two existing stations. Work at Lift Station No. 2 included replacement pumps and wet well ladder and electrical equipment. Lift Station No. 8 work included replacement pumps, addition of magnetic flow meter and replacement/upgrade of electrical power and standby power system for 100 and future 150 HP pumps. ' Project Manager - Lift Station No. 6 Replacement Ronald Wastewater District Shoreline, Washington Completed predesign, design and construction support to convert this ejector style life station to a conventional wet well/dry well solids handling wastewater pump station. The CHSENGINEEAS. LLC ' Rodney Langer, P.E. Page 3 ' existing structure was an 8' x 8' x 8' concrete cube below grade between two residences, all situated at the top of Boeing Creek ravine. The force main was routed from the station ' along the property line to the street above. The station serves about 10 homes below the road. No vehicular access is available to the station site. Working with the adjacent property owners and the District's operation staff, Rodney developed a rehabilitation plan for ' ongoing reliable operation with minimal permanent changes in the station at the ground surface. The existing vault was split into wet well and dry well spaces and all pumps, piping and controls were installed in the vault. The station electrical service and portable generator ' connection equipment was installed at the street level in an enclosure and screened from the adjacent residential properties. The force main was pipeburst for replacement with HDPE piping. Project Manager - Cherry Point Refinery Wastewater Pump Station Birch Bay Water and Sewer District ' Bich Bay, Washington Rodney developed the design criteria and led the review for this new lift station to provide domestic wastewater collection service to a nearby refinery. The project included a new ' duplex 125 gpm submersible pump station, controls telemetry and a two-mile 5 inch diameter force main and 8" gravity sewer extension. An operation and maintenance manual was prepared for the pump station. Project Manager - Lift Station Pre -design Evaluation Ronald Wastewater District ' Shoreline, Washington Prepared pre -design evaluation and report for rehabilitation of three 25+ year old lift stations. Design included addition of onsite standby power system at Lift Station No. 4 and ' replacement of sewage ejector systems with wet well/dry well pump systems at Lift Stations No. 6 and No. 11. ' Project Manager - Modifications To Lift Stations No. 1 and 2 & Flush Stations No. 9 and 10 East ate Sewer District (now City of Bellevue) ' Bellevue, Washington Lift Station No. 1 and No. 2 included electrical, ventilation, mechanical and pump modifications. Flush station work included piping, ventilation, and controls modification. ' Operation and maintenance manuals were prepared for existing stations and were updated for new equipment at completion of modifications. Construction management services included construction observation and shop drawing and pay estimate review. ' Project Manager — Lift Station No. 1 Improvements and Force Main Replacement City of Lake Stevens ' Lake Stevens, Washington Project included replacement of standby generator, electrical service, one larger pump and AC force main with PVC force main. CNS ENGINEERS. LLC 1 Rodney Langer, P.E. Page 4 Project Manager — Emergency Bypass Sewer Pump Station Ronald Wastewater District Shoreline, Washington Fast track design and construction engineering of a 3300 gpm sewer pump station and 650 feet of 12- and 16-inch diameter polyethylene force main to bypass the 175`s and 6'h Avenue Shoreline "washout". The station was design and constructed in 20 days. The "washout" occurred on December 31, 1996, and the pump station was up and running on January 20, 1997. Lift Station No. 13 Replacement Ronald Wastewater District Shoreline, Washington Project Manager for the replacement of a 25-year old wastewater pump station and force main. A pre -design report, plans, specifications and cost estimate were prepared for a new wet well/dry well type station with 450 gpm duplex pump capacity. The project included addition of an onsite diesel standby generator in an underground vault and 1,200 feet of new 8-inch force main. Services included construction management services such as shop drawing and pay estimate review, construction observation and operation and maintenance manual preparation. Also prepared application to secure funding for the project with a low - interest Public Works Trust Fund loan. Pleasure Point Pump Station Rehabilitation City of Bellevue Bellevue, Washington Assisted with plan and specification preparation for rehabilitation of existing underground pump station. Rehabilitation included replacement of pumps, piping, valves, power and control equipment, ventilation systems, wet well ladders and grating and access doors. Operation and maintenance manuals were also prepared for the station. Project Manager - Pump Station Rehabilitation, Bagley, Killarney & Meydenbauer City of Bellevue Bellevue, Washington Assisted with plan and specification preparation for rehabilitation of three existing underground pump stations. Rehabilitation included replacement of pumps, piping, valves, power and control equipment, ventilation systems, wet well ladders and grating and access doors. Operation and maintenance manuals were also prepared for each station. Project Engineer - Loomis Trail Golf Course Offsite Sewer Developer Extension Birrh Bay Water and Sewer District Birrb Bay, Washington Plans and specifications were prepared for 4,200 feet of 18" gravity sewer, a wastewater pump station and 7,200 feet of 10-inch force main to connect the golf course clubhouse and maintenance facilities to the District's collection system and to bring sewer service to a previously unsewered portion of the District. Assistance was provided for the Developer in obtaining several permits including COE Section 10 and 404, Hydraulic Project Approval, Shoreline Use and Conditional Use. Assistance was provided for the District for CHSENCW££RS, LLC Rodney Langer, P.E. Page 5 1 construction management by reviewing shop drawings and periodic/final inspections, especially for pump station. An operation and maintenance manual was prepared for the ' pump station. Project Manager - Lake Hills No. 16, Midlakes, and Palisades Pump Stations City of Bellevue Bellevue, Washington Plans and specifications were prepared for rehabilitation of three of the City's wet well -dry well type wastewater pump stations. The stations, approximately 20 years old, were each in need of ventilation systems, replacement pumps, valves and piping, wet well improvements and replacement electrical power and control systems. A standby diesel generator in an ' underground vault was added to one station. Following design, construction assistance was provided for the City in the form of progress meetings, shop drawing review and final inspections. Project Engineer - Pump Station Evaluation And Design Recommendation Report City of Bellevue Bellevue, Washington Prepared evaluation report for seven pump stations and one flush station. Report included updated discussion of condition of an additional four pump stations and eight flush stations t that had been evaluated five years prior. Each station was evaluated for safety, reliability and improved maintenance issues and design criteria established by regulatory agency or high industry standard. Design recommendations and project cost estimates were presented for each station, ranging from complete removal of the station and replacing with gravity sewer connection to several small improvements to repair deteriorated equipment or material. Basic station data and photographs of each station were included. Sunday Harbor Sewer Utility Local Improvement District (ULID), Double R Ranch Sewer ULID And Holeman Avenue Sewer ULID Birch Bay Water & Sewer District Birch Bay, Washington Preliminary engineering, preparation of SEPA checklists and estimation of project costs were completed for each of these ULID's followed by preparation of preliminary assessment rolls. Plans and specifications were prepared for a combined total of over 20,000 feet of gravity sewer mains and a wastewater pump station with standby generator. The projects required permitting at the local, state and federal level due to wetlands or proximity to shorelines. Services included preparation of construction documents, construction cost estimate, pre -construction conference, shop drawing and pay estimate review, operation and maintenance manual and periodic/final construction observation. Project Engineer - Modifications To Lift Station No. 12 Ronald Wastewater District ' Shoreline, Washington Prepared Operation and Maintenance Manual in conjunction with the rehabilitation of this station. OHS ENGINEERS, L L C EVAN HENKE, P.E., PROJECT ENGINEER ' EDUCATION B.S., Civil Engineering Arizona State University REGISTRATION Professional Engineer: Civil ' Washington Evan has 16 years of experience. Evan Henke's professional experience includes 14 years of ' planning, design, project management and construction observation of water, sewer, storm water drainage and site development projects. In addition, Evan has 2 years of pre - professional experience in construction management and materials quality control. Evan is skilled in the preparation of plans, specifications, cost estimates, assessments and computer modeling. Evan also performs well as a field engineer responsible for operations, personnel and reports. Representative Project Experience ' Sunrise Lift Station Woodinville Water District Woodinville, Washington ' Replacement of an undersized wet well — dry well station with a caisson constructed submersible station. The project included a self -draining storage well to respond to power outages. The project was constrained by a narrow site and the need to maintain sewer service throughout construction. Lift Station No. 13 Replacement Ronald Wastewater District Shoreline, Washington Plans and specifications were prepared for a new wet well/dry well sewer lift station, onsite standby power and 1,700± LF of 8" force main. This project replaced an older, undersized station. Bidding, award and construction management were performed. Grand Ridge Booster Station & Reservoir Issaquah Highlands Issaquah, Washington This project included the design of an 88,000 gallon below ground concrete reservoir with an adjacent two level pump station. The pump station incorporated two separate pumping systems, one for domestic water up to 1500 gpm, and one for irrigation supply up to 500 gpm. The station surface features were minimized and consisted of only two access hatches and an emergency generator in a sound enclosure. 11 CHS ENGINEERS, LLC ' Evan Henke, P.E. Page 2 South Hollywood Booster Station Woodinville Water District Woodinville, Washington Design and Construction Management of a booster pump station included public meetings to address neighborhood concerns, special sound attenuation measures and an interior ' emergency generator. The pumping consisted of four PLC and VFD controlled pumps rated up to 3000 gpm. ' Lake Hills #16, Midlakes, Palisades Pump Station Rehabilitation City of Bellevue Bellevue, Washington Design engineering of pump station wet well -dry well entry replacement. Analysis, design and detailing of blower vaults to provide required air exchange rate. ' Stormwater Pump Station Town of La Conner La Conner, Washington ' This project included the re -design of a drainage basin pump station after the original consultant was removed from the project and the structure had failed. The design included structural bracing and pump, piping and controls modifications to allow for site conditions. 1 2004 Water Main Replacement City of Lynnwood Lynnwood, Washington This project included the replacement and reconnection of 80001f of 6" to 16" water main. Several water meters were moved and reconnected to facilitate access. Special attention and detailing was done to provide phased connections and maintain emergency vehicle access. Richmond Beach Park Directional Drills For Water And Sewer ' City of Shoreline Shorrline, Washington Provided plans and WSDOT based specifications for two drillings for water and sewer lines to the beach facilities on lower Richmond Beach Park. Bores went under wetlands, steep slope and railroad tracks. Construction consulting was also provided. Bid in 1999 and constructed in 2000. Project No. 5/6 Water System Improvements Birch Bay Water and Sewer District Birrh Bay, Washington Plans and specifications were prepared for the construction of 9,000 LF of 8" water main. The new construction replaced an older system of 2" to 6" pipes, included 20 new fire hydrants and required detailed directions for over 150 service reconnections. CHS ENWNEERS. L L C I 1� J 1 Evan Henke, P.E. Page 3 Aspenwood Transmission Main Woodinville Water District Woodinville, Washington Plans and specifications were prepared for the construction of 5,000 LF of 12" water main. The main is adjacent to an old landfill site and required special detailing to prevent methane gas or leachate migration Pressure Reducing Station No. 1 Rehabilitation Woodinville Water District Woodinville, Washington Plans and specifications were prepared for a new 6", 500 GPM PRE' station to be located in an underground vault. The new vault was located within confinements that required special detailing of all connections. Perrinville Sewer LID 215/216 City of Edmonds Edmonds, Washington Plans and specifications were prepared, and full project management including inspection, was performed for the construction of a sewer collection system to serve approximately 230 existing homes. The project involved LID formation, easements, public meetings and critical directional drilling. 10' Avenue Sewer Main Replacement Ronald Wastewater District Shorrline, Washington Plans and specifications were prepared for a 600 LF directional drill installation of 6-inch HDPE. Construction was performed in an existing neighborhood to parallel an over- capacity pipe and remove the risk of sewage backups into existing homes. ULID No. 15 Holeman Avenue Sewer Extension Birch Bay Water & Sewer District Birrh Bay, Washington Plans and specifications where prepared for 3100 LF of 8" sewer main. A high ground water table prompted special details to prevent the sewer trench from acting as a hydraulic conduit. Low lying properties will be required to use individual sewage pumps. Aurora Village Sanitary Sewer Ronald Wastewater District Shorrline, Washington Plan review and onsite inspection of over 2500 feet of 8" sewer. The project included 11 manholes, of which 5 required special construction due to onsite conflicts. CHS ENGINEERS: L L C ' Evan Henke, P.E. Page 4 ' Southfield P.U.R.D Skagit Solutions La Conner, Washington Plans and specifications were prepared for infrastructure for a 3.2 acre, 30 housing unit planned urban residential development. The project included a 700 foot extension of Park Street and onsite paved parking areas. The storm drainage aspect included permitting for wetland mitigation, creation of bio-swale, control structure with orifice outlets, and a stormwater separator. Off site improvements included adding a wet well and submersible ' pumping to an existing storm water pump station. The project included a temporary stormwater control plan to be used during construction. ' Infiltration And Inflow Program Phase I And II Ronald Wastewater District Shoreline, Washington Phase I of the District's I&I Program included review of previous studies, delineation and prioritization of study basins, selection of flow monitoring equipment and recommendations for commencement of flow data collection and analysis. Phase II included onsite flow monitor deployment, trouble shooting and data management. Loomis Trail Golf Course Offsite Water Developer Extensions Birch Bay Water and Sewer District Birch Bay, Washington Preliminary engineering of 7,200 feet of 16-inch water main included computer modeling ' using CYBERNET to analyze effects on general supply and fire flows through out the Birch Bay Distribution System. Developed design criteria for pump stations, pipe sizing and check valves. CHS ENGINEERS. LLC FIB ri RS Richard Sample Engineer 1197 Magnolia Ave Redding, CA 96001 (530) 242-1134 Fax (530) 242-1136 email rse@integrity.com RICHARD SAMPLE, P.E. EDUCATION B.S. Electrical Engineering, California State University, Los Angeles, CA 1976 REGISTRATION Professional Engineer, Electrical; States of California, Oregon, Washington EMPLOYMENT HISTORY 2001 to Present Richard Sample Engineering, Redding CA; Owner/Engineer 1990 to 2001 Richard Sample Engineering, Bellevue WA; Owner/Engineer 1986 to 1990 Casne Engineering, Inc., Bellevue WA; Municipal Group Supervisor 1982 to 1985 Coffman/VFT Engineers, Bellevue WA; Senior Project Engineer 1978 to 1982 Thompson, Miller & Lyons Engineers, Seattle WA; Project Engineer 1976 to 1978 C.F. Braun Consulting Engineers, Los Angeles CA; Project Engineer 1972 to 1975 Southern California Edison Co., Los Angeles CA; Engineer Trainee PROFESSIONAL EXPERIENCE Twenty-nine years of experience in electrical consulting engineering, specializing in municipal project design during the last nineteen years. Extensive experience in the design of water and wastewater pump stations, treatment facilities, water wells, reservoirs and desalinization facilities. Knowledgeable in the design of instrumentation and control systems involving programmable and relay logic, soft start and variable speed pump control and telemetry interface. Experienced in designing equipment and systems to meet the requirements of state and national electrical codes and corrosive / hazardous environments. Responsible for all project elements including contract negotiations, preliminary engineering report preparation, final design drawing and specifications, construction cost estimating, bid and construction support, O & M manual preparation and final inspection. SELECTED PROJECT EXPERIENCE Municipal Pump Stations Over 75 new or extensively renovated sewer or water pump stations. Sewage Treatment Plants (22) new or extensively renovated facilities. Water Treatment Plants (2) seawater desalinization plants, (1) ozone treatment facility, (1) manganese reduction facility. Standby Power (48) projects involving a diesel generator ranging from 20 to 1000 KVA Industrial Facilities Texaco Anacortes Refinery oil separator system Reynolds Metals Co. storm water filtration system Fort Wainwright boiler plant control renovation Landfill Facilities (3) King County, WA landfill leachate or gas handling systems Electrical Utilities Tennessee Valley Authority Hartsville nuclear plant Chief Joseph Dam electrical renovation University of Alaska 10KW turbine generator Miscellaneous 2500 seat Seattle Fifth Avenue theater remodel, Boeing Renton wing paint facility, Paccar Headquarters, 132K SF Administration building, (7) North Slope Alaska fire stations, 70 bed hospital, remodeled (6) historic libraries banks, office buildings, (3) corporate computer data centers, Navy supply center, auto ferry terminal, (4) public park lighting projects. RSE resume (11-1-05) ROBERT J. CASNE, P.E EDUCATION • BSEE, Montana State University, 1964 REGISTRATION Electrical Engineer: Washington, California, Oregon, Montana, Nevada, Arizona, Hawaii, Alaska, Idaho, ' Virginia, New Mexico • Control Systems Engineer: California, Oregon PROFESSIONAL SOCIETIES • The Institute of Electrical and Electronics Engineers, Inc. • The Electric League, Codes Committee 1 EXPERIENCE SUMMARY Robert Casne has served the electrical industry for the past 40 years. The majority of that time has I been in the water and wastewater consulting industry for municipal clients. His experience began at the project engineer level and expanded to include single project management and progressed to management of multiple projects simultaneously. Mr. Casne has a wide range of expertise in with ' respect to electrical, SCADA and telemetry systems for wastewater and water pumping and treatment projects. In addition to his electrical expertise he is familiar with issues concerning electrical interface with other engineering disciplines, which adds to his value in the role of ' electrical project manager. Mr. Casne has excellent communication skills, both oral and written, another essential skill in successful project management. Mr. Casne is also familiar with MS Project and other software used in project management. A summary of projects for which Mr. Casne served as project manager or project engineer include the following. MOSES LAKE CENTRAL OPERATIONS FACILITY, SEWAGE PLANT, AND PUMP STATIONS I Mr. Casne served as Senior Design Engineer for the electrical and control systems design for the project. This project involved the complete electrical renovation of 11 pump stations. Work included new service, new motor controls, wet well level sensing, and telemetry. Five large 1 capacity pumping stations were modified to include on -site standby power generators. Six smaller stations were modified to accept connection to a portable generator. The project involved the construction of a new central operations facility and pumping station at the site of the old sewage ' treatment plant. The new pumping station pumped to a new sewage treatment plant via a new pipeline under Moses Lake. A large generator was located at the Central Operations Facility with a new SCADA and control system for the entire collection and treatment system. RENTON PRIMARY SERVICE CONSOLIDATION STUDY, RENTON, WA Mr. Casne served as Project Manager in negotiating with the Puget Sound Power & Light Company to purchase the primary lines throughout the City of Renton's Cedar River Park. The project extended the primary metered service from Well # 8 to the Community Center, Theater and ' Well #9. 11 CEDAR RIVER WATER AND SEWER DISTRICT, RENTON, WA Mr. Casne served as Project Manager for the SCADA system study for Cedar River Water and Sewer District. Effort included site evaluations, alternative analysis, cost estimates, and final ' report. BELLEVUE PUMP STATION NO. 12, CITY OF BELLEVUE, WA Mr. Casne served as Senior Design Engineer for the electrical and control system for Lift Station No. 12 modification. This project involved a high head sewage pumping application. An innovative technique was used to accomplish high head pumping. Four pumps with two pumps operating in tandem were replaced with two 200hp sewage pumps, each controlled with a variable frequency drive unit. The motors were driven at two set speeds, 60 hertz and 72 hertz. The 72 hertz speed was used for high flow, high head pumping conditions. A programmable logic controller was used to control the operation of the pump station based on wet well level. A pressure transducer was used to sense wet well level with float switch back-up. The project included a standby generator and an RTU for interface with the City's telemetry system. KING COUNTY WASTEWATER DIVISION, 53RD AVENUE PUMP STATION MODIFICATIONS, SEATTLE, WA Mr. Casne served as the electrical and instrumentation and control engineer for this project. This station was completely rehabilitated. The project involved removal of two 150 hp motors and ' pumps and the installation of two 150 hp two speed two winding motors. The motors were started using autotransformer starters. The station operated at 480Y/ volts. A complete new level sensing system replaced the existing bubbler system. An ultra -sonic level sensor system was used with ' float switches for alarm conditions and back up controls. A Texas Instruments PM 550 programmable controller was used for logic and control. SNOHOMISH WASTEWATER TREATMENT PLANT TELEMETRY EXPANSION, SNOHOMISH, WA Mr. Casne served as Project Manager of the expansion of the City of Snohomish Wastewater ' Treatment Plant. This project included design of a SCADA system for monitoring and control of the City's treatment plant and all of the City's 11 lift stations. The lift stations are monitored using a graphic programming software by Wonderware on a PC located at the treatment plant and data is transferred via radio telemetry. BOOSTER PUMP STATION 297, SAMMAMISH WATER & SEWER DISTRICT, WA Mr. Casne was Project Manager of this project. The Project involved the electrical and control systems design for two 450hp and one 150 hp booster pumps. The two large pumps use solid-state starters for soft starting and soft stopping and the 150 hp pump reused an existing auto transformer starter. The station has provisions for an emergency generator and employs a PLC control system tied into the District's telemetry system with radio communications. RALPH BOIRUMPE 1, Geotechnical Engineer, Principal MS, Civil Engineering, University of Illinois BS, Civil Engineering. University of Illinois Registration —Professional Engineer Washington 1976, Alaska 1980, Oregon 2003, Illinois 2003 Affiliations —American Council of Engineering Companies of Washington (President) Society of American Military Engineers Mr. Boirum has a masters degree in civil engineering and 34 years of geotechnical consulting experience in the Northwest. During those years, he acquired well-rounded experience working on more than 4000 geotechnical engineering projects ranging from small residential jobs to large transportation projects and heavy industrial plants. These projects have included field explorations, design studies, contract drawings and specifications, and report preparation. He has followed many of these projects through construction and has extensive experience in foundation and earthwork construction, including construction management and construction monitoring. He has managed geotechnical studies and provided design recommendations for more than 50 Water and Sewer Systems, Treatment Plants, Reservoirs, Tanks and Lift Stations in the Pacific Northwest. In addition to his geotechnical consulting work, Mr. Boirum taught courses in soil mechanics and foundation engineering at Seattle University for 13 years, and has been teaching geotechnical engineering at the University of Washington for the past three years. Waterworks Project, Renton Wastewater Treatment Plant, Renton, Washington. Managed geotechnical studies for the design of a nature trail / park, including a series of ponds, walkways and wetlands at the northwest corner of the treatment plant site. Eastside Interceptor Project, Renton Washington. Managed geotechnical studies to restore capacity lost in a 108-inch diameter sewer line as a result of pipeline displacement during an earthquake. Soil liquefaction during the 1965 earthquake caused the pipeline to float several feet upward reducing its flow capacity. Provided assistance with studies to restore the lost capacity, which resulted in design of a new 72-inch ID 1900-foot long pipeline to bypass the damaged section. The new pipeline averaged 28 feet deep through soft wet soils in a business and residential neighborhood. Conditions dictated that the new pipeline be installed by jacking an earth -pressure - balance (EPB) tunneling machine. Swamp Creek Trunk Sewer, Kenmore, Washington. Project manager for geotechnical investigation for design of a 4200-foot sewer line. 48 inches in diameter, to replace an existing smaller line. Approximately 1200 feet of the pipeline was greater than 20-feet deep, and was installed by bore -and -jack tunneling. Another bore and jack tunnel was used to install the sewer beneath Swamp Creek at the south end of the project alignment. The remainder of the sewerline was installed by conventional open trenching. Several 8-inch laterals and manholes were installed and connected to the new 48-inch pipeline. Provided design and construction recommendations for open trench and trenchless construction, construction dewatering, shoring for jacking and receiving pits, excavation, pipe bedding and backfill, and pavement reconstruction. Prepared a geotechnical Baseline Report and assisted in preparation of plans and specifications. Reviewed submittals and provided monitoring and consultation services during construction. Denny Way CSO Project, Design Studies, Seattle Washington. Managed geotechnical investigation for design ' of five connector tunnels, ranging from 72 to 96 inches inside diameter. Three of these tunnels crossed beneath multiple sets of active railroad tracks at depths ranging from 5 to 55 feet. The other two tunnels were 72-inch ID pipelines approximately 710 and 1800 feet long extending beneath city streets and utilities. Directed exploration ' programs and geotechnical engineering studies for all five tunnels as well as pump tests and dewatering studies for these tunnels and the 14.5 foot diameter 6200-foot long Mercer Street storage tunnel. Design studies included review of plans and specifications and preparation of geotechnical reports, geotechnical baseline reports, and geotechnical data reports for all tunnels. Also provided analyses and consultation during construction. Tolt Pipeline No. 2, Phase IV, King County, Washington. Managed the geotechnical investigation for a proposed 6.5-mile, 54-inch diameter pipeline extending from Woodinville to Lake Forest Park, Washington. Provided geotechnical recommendations relating to construction issues including the use of trenchless methods for stream and roadway crossings. North Creek Pump Station and Pipeline, King and Snohomish Counties, Washington. Managed geotechnical investigation for design of a pumping and conveyance facility for the diversion of wastewater flows within the King County Metro sewer system. The dual -pipeline is approximately four miles in length, extending from Bothell southward to the York Pum ing Station at the northern boundary of Redmond, Washington. The alignment included Y H1wAGEOSCIENCES INC Geotechnical & Pavement Engineering . Environmental Engineering & Ground Water Geology . Material Testing & Inspection J �1_ crossings of the SR 522 freeway, the Sammamish River, three sections of railroad, two major roadways, and a major water supply pipeline (Tolt Pipeline). Evaluated alternative methods of construction along sections of the alignment, including open -cut, pipe -jacking, microtunneling, directional drilling, and sheet pile cofferdams. Special recommendations were provided for sections of the alignment traversing highly compressible organic soils. The necessity and extent of dewatering was evaluated along the pipeline route. Geotechnical studies also included settlement and uplift potential, seismic issues, lateral earth support, preloading and evaluation of alternative foundation types for the proposed pumping station. During construction, provided evaluation of the site preload and consultation on various geotechnical issues. Sweyolocken Pump Station, Bellevue, Washington. Principal -in -Charge of geotechnical study for pump station upgrades which included construction of a new wet well, generator room, and pipelines to new structures that will require crossing of Bellevue Way SE. Design recommendations were provided for the concrete mat foundations; to address potential liquefaction of the subsurface soils, uplift and buoyancy concerns for the structures; temporary shoring for both the shallow and deep foundations; and to provide dewatering information for the contractor during construction. Everett Lift Station 10 Bypass, Everett, Washington. Managed the geotechnical investigation for an approximately 1350-foot long pipeline in an active landslide area. Directional drilling recommendations were provided for installation of the 12-inch diameter pipe, which connects Lift Station No. 10 with the middle segment of the South End Interceptor. Slope stability issues including drainage considerations, potential slope movement and the use of flexible connections were discussed. Performed building crack evaluations prior to construction and provided geotechnical consultation during construction of the pipeline. King County Conveyance System Improvements, King County, Washington. Managing preliminary geotechnical investigation for the proposed Hidden Lake Service Area sewer and pump station improvements. Engineering analyses include evaluating two separate routes for the 7000-foot pipeline and both open cut and tunneling approaches. Lakeland Hills Pump Station, Auburn, Washington. Principal -in -Charge of geotechnical investigation for upgrades to the existing pump station, which included a new dry well, electrical room, generator room and odor and corrosion control room. Recommendations were provided for foundation design, liquefaction, uplift and buoyancy of the wet well, temporary shoring for excavations, and dewatering. Infiltration testing was performed to assist in design of a stormwater infiltration system. Kenmore Pump Station, Kenmore, Washington. Managed geotechnical study for a new generator building and chemical injection tank. Recommended a pile -supported foundation to design for the loose liquefaction prone fill soils that dominated the site. Also recommended pre -drilling the timber piles to minimize the vibrations caused by pile driving and using fixed lead to minimize the lateral component of the hammer blows. West Camas and South Prune Hill Pump Stations, Camas, Washington. Oversaw the geotechnical investigation for two pump stations approximately 2,000 feet apart in Camas, Washington. Both structures were required to replace existing structures and consisted of 8-foot diameter concrete shafts to depths of about 30 feet below ground. The main feature of the project, identified in the exploratory rotary core borings, was the presence of hard fractured bedrock from shallow depth at both locations. Investigated various approaches for excavating the bedrock and supporting the excavations sides. ' Stanwood Pump Station Renovation, Stanwood, Washington. Principal -in -Charge of geotechnical investigation for pump station improvements. Upgrades included a one-story above -grade structure over an existing below -grade structure and replacement of a section of force main between the pump station and the street. Recommendations ' were provided for foundation design and dewatering for pipeline excavation. Lake Stevens Wastewater Treatment Plant, Lake Stevens, Washington. Principal -in -Charge of geotechnical investigation for treatment plant improvements, which included access road rehabilitation, a new waterline, a ' canopy over the existing headworks building, chlorine contact tank conversion to a UV exposure basin, and a new vehicle ramp to the tank. Geotechnical recommendations were provided for the use of steel plates on the road to distribute the load from heavy truck traffic, the use of horizontal directional drilling to probe the waterline alignment, ' the use of bottom ash to partially fill the existing chlorine contact tank so that the UV exposure basin could be placed within it without overloading the pile foundations, and the use of bottom ash contained between two rows of mechanically stabilized earth (MSE) walls attached by geogrid to build the ramp. 1 VVV HWA GEOSCI ENCES INC. Geotechnical & Pavement Engineering • Environmental, Engineering, & Ground Water Geology • Material Testing & Inspection ERIK O. ANDERSEN, PE Geotechnical Engineer MS. Civil Engineering, University of Washington BS, Civil Engineering, California State Polytechnic University, San Luis Obispo Registration —Professional Engineer Washington 2000 Affiliations —American Society of Civil Engineers (ASCE) Mr. Andersen has a masters degree in civil engineering and 10 years of geotechnical consulting experience in the Pacific Northwest. A significant proportion of Mr. Andersen's geotechnical work experience has been on water and sewer projects. He has been involved in projects ranging from distribution and collection lines, new pump stations, and new treatment plant facilities, and upgrades to existing treatment facilities. Several of these projects involved pipelines installed by open cut or trenchless methods below ' the ground water table. He has also worked on submarine outfall projects, and has been involved in pipeline capacity improvement projects using methods such as pipe bursting, and CIPP (cured in place pipe) lining. ' Eastside Interceptor Section 1 Capacity Restoration Project, Renton, Washington. Project Engineer for the project that involved the installation of an approximately 1850-foot long 6-foot diameter wastewater pipeline, with an average depth of about 25 feet beneath the ground surface. Serving as project geotechnical engineer, Mr. Andersen performed the field explorations, evaluated laboratory test results, and developed subsurface geologic profiles. He co-authored the design geotechnical reports, geotechnical baseline report (GBR), and geotechnical data report (GDR). Recommendations pertaining to excavation support, dewatering, tunneling, foundation support conditions, pipe bedding and backfill, and seismic considerations, were provided. Challenging soil conditions included loose/soft silty alluvium with high ground water levels. Construction dewatering was not allowed during ' construction because significant settlements were likely. Prior to construction, Mr. Andersen conducted a detailed pre -construction photo -survey of existing residences along the project alignment. The pipeline was installed by EPB slurry tunneling methods. LOTT Wastewater Project, Lacey, Washington. Project Engineer for the facilities that consist of a new Hawks Prairie Satellite Reclamation Plant, improvements to the existing Martin Way Pump Station, and conveyance lines. The raw sewage conveyance line from the pump station to the plant will traverse along East Martin Way beneath a wetland area, and may require trenchless construction methods for a significant part of its length. The reclaimed water conveyance line from the plant to the outfall site will have trenchless road crossings at East Martin Way, and at the intersections of Britton Parkway and Marvin Road. A preliminary geotechnical engineering assessment of ' the general area of the facilities was performed and a brief report was prepared outlining geotechnical conditions and design considerations for the siting and design of the facilities. Site and location -specific geotechnical investigations for the facilities were then performed. Separate reports were prepared for the Hawks Prairie Satellite Reclamation Plant site and various plant components, for the proposed improvements to the Martin Way Pump ' Station, and for the conveyance lines between the pump station and plant and from the plant to the outfall location. Recommendations were provided for foundation support for the various structures and treatment facility units on both the plant and pump station sites. Earth and potential ground water pressures and dewatering needs for buried facilities were discussed, and recommendations and guidelines for site grading and drainage considerations, for open -trench and trenchless construction of the underground conveyance lines, and for roadway and parking lot pavement development, were also provided in the reports. As project geotechnical engineer, Mr. Andersen conducted geotechnical engineering analyses in support of design and construction of a pile -supported pipeline bridge over Woodland Creek, along Martin Way. Sweyolocken Pump Station, Bellevue, Washington. Project Manager for pump station upgrades which included construction of a new, wet well, generator room, and pipelines to new structures that will require crossing of Bellevue Way SE. Design recommendations were provided for concrete mat foundations, uplift and buoyancy concerns for the structures; temporary shoring for both the shallow and deep foundations; and construction dewatering. ' Lift Stations 7 and 8 Improvements, Edmonds, Washington. Project manager for geotechnical studies for a sewer lift station, and over 1,500 feet of new gravity sewer lines. The new lift station is located in close proximity to the existing BNSF railroad, and it will be founded below the ground water table. A detailed geotechnical investigation will be completed so that engineering analyses can be performed and recommendations made for design and construction of the temporary excavation for the lift station and for the new sewer lines. Challenges include a high ground water table, highly compressible, very soft organic soils, and the proximity of the project to ' the BNSF railroad tracks. V M11 Getechnical & Pavement Engineering . Environmental, Engineering N & Ground Water Geology • Material Testing & Inspection r Tom C. Xia PhD, P.E., S.E. ' Principal/Technical Director EDUCATION PhD. Civil Engineering. University of Michigan, 1990 M.S. Civil Engineering. Taiyuan University of Technology, 1985 ' B.S. Civil Engineering. Taiyuan University of Technolop .1981 11 I 1 REGISTRATION Civil & Structural: Washington, Oregon PROFESSIONAL SOCIETIES American Socict\ of Civil Engineers (ASC1 ) American Concrete Institute Structural Engineers Association of Washington (SEAW) Tau Beta Pi Honorary Society DCI ENGINEERS EXPERIENCE Tom Xia has worked as project manager and senior structural engineer on a wide variety of projects, including medical and office buildings, high-rise buildings, condominiums and retirement centers, tilt -up warehouses, multi -story parking structures, large screen theaters, airplane hangers, wastewater treatment plants and paper mills. He has conducted seismic analysis of complex structures, special foundation design, evaluation and retrofit of existing structures, long span roof truss analysis and design, floor vibration study, built-up member and special connection designs. His working experience also includes project development and management, preliminary design, cost estimation, value engineering, field investigation and construction support. He serves on numerous local and national technical committees for building code and standard development. Xia is a creative, hard working, team member who has solid skills and extensive experience to design and manage projects efficiently and economically for his clients. In 1996, his team on the NPIC project won the Excellence in Concrete Construction Award given by the Washington Aggregate and Concrete Association. The South Park Commercial Development Project has won the 2001 Excellent in Construction Award by Associated Builders and Contractors. His recent project, the 5`h and Jackson Building, has won the 2003 Outstanding Project Award by National Council of Structural Engineers Associations. SELECTED PROJECT EXPERIENCE Sunrise Lift Station — Wet/Dry Well Structure, Woodinville, Washington, CHS Engineers, Inc. Grand Ridge Water System, Issaquah, Washington, CHS Engineers, Inc. Timberlake Pump Station, Shelton, Washington, CHS Engineers, Inc. LaConner Wastewater Treatment Plant, LaConner, Washington, CHS Engineers, Inc. LaConner Water Tank, LaConner, Washington, CHS Engineers Clinton Water Reservoir No. 2, Clinton, Washington, CHS Engineers, Inc. Clinton Water District Hilltop Reservoir, Clinton, Washington, CHS Engineers, Inc. Pump Station Remodel #12, Bellevue, Washington, CHS Engineers, Inc. Miller Creek Wastewater Treatment Plant, Des Moines, Washington, CHS Engineers, Inc. Edmonds Meter A Vault, Edmonds, Washington, CHS Engineers, Inc. Three Lakes W.A. Pump Station, Everett, Washington, CHS Engineers, Inc. Snohomish Wastewater Treatment Shoring, Snohomish County, Washington, McClure and Sons Safeway — Water Treatment Enclosure, Bellevue, Washington, Safeway Beverage Plant SELECTED PERSONAL EXPERIENCE JGC Waste Water Treatment Facility, Hanford, Washington 1 Mark Moorleghen EXPERIENCE P. S.E. Mark Moorleghen's diverse design and project engineering experience spans more than Associate, Senior 20 years including four in a fast -track, design -build environment. He has managed both design engineering and project engineering in the commercial, industrial and public Project Manager works sectors, and knows how to manage, scope, schedule, and budget to achieve value for clients. As a structural engineer, Moorleghen has designed structures in concrete, steel, EDUCATION masonry, and timber. He has also designed architectural elements of buildings and civil B.S.. Civil elements as required. The result has been products that were delivered on time and lEngineering.tcis Virginia Polytechnic constructed in a cost-effective and efficient manner. Institute. 1980 Moorleghen's recent experience includes water tank inspection and repair, wastewater treatment facilities, petrol -chemical, mixed -use, residential, multi -family, office, and REGISTRATION medical buildings. He also has experience in semiconductor, aerospace and metals Civil & Structunjl manufacturing, transportation infrastructure, institutional boiler plant, shipyard, and Washington pulp and paper facilities. An effective team leader and player, Moorleghen asks the right questions at the right time. SELECTED PROJECT EXPERIENCE Pump Station #12, Bellevue, Washington, CHS Engineers, Inc. Birch Bay Waste Water Treatment Plant Headworks, Birch Bay, Washington, Birch Bay Water and Sewer District, CHS Engineers, Inc. Birch Bay Water and Sewer District Reservoirs — Steel Water Tank Seismic Analysis, Birch Bay, Washington, CHS Engineers, Inc. Safeway -Water Treatment Enclosure, Bellevue, Washington, Safeway Beverage Plant — Bellevue Tank Foundation — WestFarm, Seattle, Washington, WestFarm Foods K and N Meats — Boiler Remodel and Addition, Renton, Washington, CollinsWoerman NPPI (Fishery Processing Plant) — Fire Damage Reconstruction, Cordova, Alaska, BK Roberts and Associates Simpson Timber Mill (Kiln Foundations, Ship Loader Foundations), Tacoma, Washington, Simpson Timber Company Simpson Paper — Bleach Plant, Tacoma, Washington, Simpson Timber Company SELECTED PERSONAL EXPERIENCE Renton Treatment Plant III- C — Dissolved Air Flotation Thickeners (Underground Tanks), Renton, Washington, King County METRO Waste Oil Tank Installation — Kaiser (Tank Foundations, Containment Structures, Pipe Racks), Spokane, Washington Oil House Tank Farm — Kaiser Aluminum (Tank Foundations, Containment Structures, Pipe Racks, Underground Trenches), Spokane, Washington D C 1 ENGINEERS Sedimentation Tanks — Conoco, St. Charles, Louisiana 1 Summerwind and Stonegate � Lift Station Consolidation and � Field Avenue Interceptor I Statement of Qualifications and Proposal ' Prepared by: rAIPACE 11255 Kirkland Way, Suite 300 ' Kirkland, WA 98033 425.827.2014 L LETTER m= m m m= s= m m m= m m m i 1 1 PACE An Engineering Services Company December 12, 2006 1 Mr. David Christensen, P.E. Wastewater Utility Engineering Section 1 City of Renton 1055 South Grady Way Renton, Washington 98055 Engineers Planners Surveyors 1 RE: Summerwind/Stonegate Lift Station Consolidation and Field Avenue Interceptor 1 Dear Mr. Christensen: Thank you for the opportunity to propose on your project for consolidating the Summerwind and 1 Stonegate Lift Stations. We have reviewed the material forwarded with the RFP as well as additional information 1 obtained from the City of Renton in order to craft a proposal that truly meets the needs of the project. 1 PACE certainly has the technical capability to provide an efficient, effective, and constructible design for the lift station. We have recently completed several similar stations and will bring that fresh experience to bear. We will apply our many years of successful project work to completing ' a custom design that is both timely and economical. We think that the real opportunity for increasing value on this project in comparison to a typical design is in reaching early agreement with the City and other stakeholders on the scope and ' design criteria that will be used. The most important task that the design team can undertake is to define the technical standards applicable to this project in detail early in the project, codify them in a written document that is accepted by all of the stakeholders, and avoid changes mandated by 1 review comments made in the middle of the design process. The greater the level of early detail the greater the level of certainty regarding actual construction costs. 1 We are confident that we can offer you a truly best -value solution based on our technical and management experience and we look forward to working with you. Please contact me if you have questions or require additional detail. 1 Sincerely, ' PACE Engineers, Inc. ' Gareth A. Grube, P.E. Project Manager PACE Engineers. Inc. Kirkland Office 11255 Kirkland Way I Suite 300 1 Kirkland, WA 98033 /, 425.827.2014 1 1 425.827.5043 paceengrs.com TABLE OF CONTENTS TABLE OF CONTENTS ProjectApproach................................................................................................................1 ProjectSchedule.................................................................................................................5 Project Management...........................................................................................................6 Project Team Members......................................................................................................7 References.........................................................................................................................14 LiabilityInsurance.............................................................................................................14 Additional Information RESUMES: - Marty Penhallegon, P.E., Principal -in -Charge - Gareth Grube, P.E., Project Principal - Dave Hutley, P.E., Sr. Project Manager - John McAlpine, P.E., Design Engineer - David Fulton, P.L.S., Survey Manager - Steven Wright, P.E., Geotechnical Engineer - Sam Casne, Senior Environmental Specialist - Vince Follett, Electrical Engineer rR�E� City of Renton Design of Summerwind/Stonegate Lift Station Consolidation PROJECT APPROACH m m m m m m m w m w m m m m m m m m m PROJECT APPROACH 1 PACE has examined the available project conception documentation and development of the City of Renton's Summerwind/Stonegate Lift Station Consolidation project. Based on this analysis we have organized a project approach that responds to each of the key elements identified in the RFQ and expands on them as necessary to incorporate our own recent experiences on what seems to work and what does not in wastewater lift station design. A - PROJECT APPROACH Task 1— Alternative Analysis Rationale: Population growth in the service area for the pump stations has exceeded expectations. Increasing the lift station capacity is clearly required. This increase could entail significant construction before embarking on a major construction project, a reevaluation of alternatives for meeting wastewater conveyance and disposal needs is mandatory. A part of this analysis will be development of a defined set of general lift station standards for the City. Particular areas of interest include maximizing use of existing facilities where feasible to contain project construction costs and ensuring that existing service is maintained as transparently as possible through a detailed bypass and switchover plan for the new facilities incorporates input from all stakeholders — the public, engineering staff, and maintenance personnel. Action Outline: Subtasks within this task include: C_(_'1a. Data Gathering/Criteria Development: This subtask will include organizing and validating/confirming (as necessary) the assumptions and stakeholder expectations surrounding the construction of a new facility in this location. Regulatory and permitting standards and applicable codes will be identified and listed to ensure that there are no key requirements missed and no surprises as the project proceeds. Some of the key areas of consideration are environmentally sensitive integration of the wastewater conveyance function into the neighborhood including stormwater management, visual/aesthetic impacts and their mitigation, and site security. In addition to the City of Renton's published standards, this task will also become the forum for establishing any unwritten preferences generated by the operations staff through recent similar project experience in the City. b. Define Alternatives: This subtask will result in an array of alternatives that meet the necessary wastewater conveyance function and will flesh out the parameters and issues surrounding each. C. Preliminary Engineering: Each alternative will need to be developed to a level that will capture all cost and environmental impacts for equitable comparison. Economic and non- economic factors will be quantified so that fair comparison of alternatives is possible. For those issues that have significant public impact, public participation will be solicted. d. Cost Estimating: Recent volatility in construction costs has had a major impact on infrastructure markets. PACE maintains a portfolio of estimating results as well as routine communication with contractors to keep our estimates reflective of current trends and responsive to material and equipment cost changes. e. Design report: This subtask will result in a written document comparing the alternatives available to the City and will present in matrix form the key differentiators between alternatives. The Design Report will contain our recommendation for project design and will clearly identify any remaining unknowns or areas requiring further investigation. Gareth Grube will draw on PACE's extensive experience in the wastewater pumping arena to City of Renton Design of Summerwind/Stonegate Lift Station Consolidation 9 Page 1 PROJECT APPROACH 1 �I ensure that the City of Renton receives the benefit of similar experience in each of the key areas. Task Lead: Gareth Grube, P.E. Task 2 - Project Design Rationale: After review by the stakeholders and a decision about which alternative is preferred, the PACE team will produce a technically responsive and cost-effective wastewater pumping and conveyance design. Action Outline: Subtasks within this task include: a. Criteria Confirmation: PACE will confirm the applicability and acceptability of the design criteria developed during the preliminary engineering subask and make any necessary modifications for wide distribution to the design team and City stakeholders. b. Topographic Survey: PACE will develop the mapping and property ownership information to prepare a detailed base map. (Subtask Lead: David Fulton) C. Public Involvement: Under the current baseline alternative, construction and operation of the pumping and conveyance facilities will have an impact on an existing developed residential area. Resident and public input to alternative selection, construction approach, and construction timing will be obtained and incorporated into the design. d. Geotechnical Exploration: Landau Associates will conduct the necessary field exploration and laboratory testing to characterize the soils along the pipeline routes and at the selected lift station sites. The PACE team will ensure that design selections recognize the nature of the soils that will be encountered during construction. Design: PACE will organize and direct the design process to iteratively develop a technically superior design product that offers a balance between innovation and tried-and-true J techniques, and delivers maximum operational flexibility, optimal mai nce efficiency, and truly cost -sensitive solutions to the City of Renton. We will develop the design in egr ing existinc reaulatory guidelines, City mandated preferences, and our professional experience considering structura in - c evalue maintenance, ease of operation, potential for future modification, pending regulatory changes, and myriad other issues and considerations that contribute to a successful product. As a part of both the negotiation of scope and preparation of the basis of design, we will clearly define the extent of deliverables that are anticipated for each of the submittal stages (35, 65, and 95 percent. 1. Lift Station Design: (Subtask Lead: Dave Hutley) Dave will be responsible for implementing the criteria determined in the alternative analysis phase and implementing that criteria in design of the station. 2. Interceptor and Force Main Design: (Subtask Lead: John McAlpine) John will handle the engineering and design of the conveyance piping including the Field Avenue Interceptor enlargement, the new gravity line from the Summerwind Station to the upstream end of the Stonegate influent sewer, and the new force main from Stonegate (or other site) Lift Station to the Field Avenue Interceptor. ` Deliverable Quality Assurance: This task will define the positive actions taken to ensure that we deliver a "no -problems", trouble -free design to the City of Renton. We will take advantage of the more than 35 years of experience Marry Penhallegon offers in dealing with reservoir design in general and the City of Renton in particular to create a functional design that exceeds stakeholder expectations. (Subtask Lead: Marty Penhallegon) Task Lead: Gareth Grube, P.E. City of Renton Design of Summerwind/Stonegate Lift Station Consolidation E Page 2 PROJECT APPROACH ask 3 - Bid Document Preparation Rationale: The clearest possible documents and instructions to the contracting community are essential to prevent and mitigate confusion in the field and create adversarial relationships. Action Outline: PACE will assemble the design documentation and organize it in a way that is clear, comprehensive, and constructible. Task Lead: John McAlpine, P.E. Task 4 - Permit Assistance Rationale: Close attention to the requirements and processes for permit acquisition from the internal and external overseeing agencies will minimize project duration, eliminate repetitive submittals, and prevent surprises. Action Outline: Many of the required permits have been determined. During the development of the Design Report document, PACE and the project team will identify any potential permits and their detailed requirements with an eye toward making any mandatory decisions early in the process. Any opportunities to incorporate permit mitigations into the ongoing design process will be considered and acted on. Task Lead: John McAlpine, P.E. ' Task 5 — Assistance During Bidding Rationale: Presenting the finished design to the construction community, ensuring a common level of understanding among the bidders, and receiving proposals must be organized and carefully recorded. ' Action Outline: This task will result in the identification of a responsive and responsible bidder following existing contract and municipal procurement guidelines. PACE has systems in place to assist the City or to support existing City of Renton processes for distribution of bid documents bidder ' responses, clarifications, bid receipt and other technical and administrative tasks. Task Lead: John McAlpine, P.E. Task 6 - Construction Period Services Rationale: Project oversight at a number of levels is important to ensure that the selected contractor understands the intent and letter of the construction documents. Action Outline: Subtasks within this task include: a. Construction Progress Assistance: PACE is comfortable with provision of on -site personnel if required or other specified arrangements to have the appropriate staff on site at the necessary times to ensure that oversight. We provide such services on a regular basis to a number of utility agencies and have established both internal inspection and review standards and detailed construction reporting models for the City's consideration. Review of submittals, contractor RFIs and change order negotiation are well within our professional capabilities and expertise. PACE has any necessary field survey capability in-house and ready on relatively short notice to support the construction management effort. b. Engineering Support: Dealing with the changes that inevitably occur during construction require personnel experienced in evaluating the technical merits of the proposed change as well as recognizing the ripple impacts of change on the design and construction contract. PACE is skilled in meeting this challenge. C. Startup and Initial Operations Assistance: PACE's work during this subtask includes directing changeover efforts, overseeing staff training, and field testing to confirm satisfactory __�peration. — City of Renton Design of Summerwind/Stonegate Lift Station Consolidation 6;i_=7E) Page 3 PROJECT APPROACH F] d. Record Drawings: This subtask includes modification of the construction drawings to reflect the- -c. Lions encountered in the field and to incorporate changes that may have occurred during construction. e. Operation and Maintenance Manual: The assumptions, operating conditions, and special characteristics that are inherent in the new lift station and force main system must be recorded and made available for operator review or new operator training. Task Lead: John McAlpine, P.E. Task 7 — Project Coordination & Management Rationale: Effective management will optimize the planning, design, and construction effort and create a successful win -win project for the City, ratepayers, and locally affected citizens. Action Outline: This task includes the big -picture look at the project and developing and understanding the expectations and objectives of the City of Renton and directing a team of professionals to deliver to meet those objectives. Communication (both internal and external to the team), record keeping, contract administration, subconsultant management, schedule monitoring and revision, and formulating necessary adaptive responses to change will be paramount activities under this task. Task Lead: Gareth Grube, P.E. A2 - TIME SCHEDULE The schedule that appears on page 6 represents our best estimate of the project delivery process. A3 - TEAM MEMBER TIME SCHEDULE We estimate that the team members we have identified will be committed to this project in accordance with the following table: Marty Members Gareth EstimatedTeam Dave H. Hours John for Project David F. Support CAD Subconsultants Alternative Analysis 8 16 32 24 40 40 24 Design 16 40 150 120 200 240 240 160 Construction Documents 16 24 24 40 40 40 Permit Assistance 24 24 80 40 40 Bid Assistance 8 8 40 40 24 Construction Services 40 16 80 200 120 80 Project Management 24 80 8 8 Total Hours 64 232 262 392 400 280 520 368 City of Renton Design of Summerwind/Stonegate Lift Station Consolidation A E Page 4 PROJECT SCHEDULE CITY OF RENTON SUMMERWIND/STONE GATE LIFT STATION CONSOLIDATION PROJECT SCHEDULE 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 1st Quarter 2nd Quarter 3rd Quarter ID Q JTask Name Duration Jan Feb Mar Apr May .Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep I 1 E3 Notice to Proceed 0 days 1/29 2 Alternative Analysis 25 days 3 Data Gathering 10 days 7 4 Alternative Definition 5 days 5 Preliminary Engineering 15 days I _ 6 Cost Estimating 5 days 7 Submit Design Report 10 days 8 City of Renton Review 15 days 9 Project Design 125 days 10 Prepare 35% Design 30 days 11 Submit 35% Design 0 days 5/4 12 City Review 10 days 13 Design Development 30 days 14 Submit 65% Design 0 days 6/29 15 City Review 10 days 16 Design Completion 30 days 17 Submit 95% Design 0 days 8/24 18 City Review 15 days 19 Bid Document Preparation 15 days 20 Permits and Approvals 120 days 21 Bidding and Award 30 days i 22 Construction Period Services 210 days 23 Services During Construction 180 days 24 Startup and Commissioning 30 days 25 Q Project Management 365 days . 9/ 26 Project Completion 0 days Task ♦ External Tasks Project: City of Renton Summerwind : Split Summary External Milestone Date: Fri 12/8/06 Progress Project Summary �� Deadline Page 1 PRO) ECT MANAGEMENT PROJECT MANAGEMENT ' B1 - PROJECT APPROACH ' In completing more than 100 lift station projects in this region during our firm history, we have learned some valuable lessons about the process of wastewater project delivery. We have established contacts within the regulatory and permitting agencies. We have a history with most of the major contractors and ' suppliers. Our management approach will build on this bank of knowledge and association to the benefit of the City of Renton. Management is based on some relatively simple principles of communication (learn to listen as well as speak, make sure that information is widely disseminated) and accountability (own up to and learn from your mistakes) as well as on modern tools, techniques, and software. PACE will bring both the latest electronic management and reporting tools as well as this proven professional philosophy to our work for the City of Renton. We anticipate that the following organization chart will offer the maximum of efficiency and communication with all members of the PACE team: ' B2 - ORGANIZATIONAL CHART t Dave Christensen, P.E , Project Manager ' City of Renton ' Marty Penhallegon, Gareth Grube, P.E., P.E., Project Manager Principal -in -Charge PACE ' PACE Dave Hutley, P.E., David Fulton, P.L.S Steven Wright, P.E., ' Project Engineer Survey Manager Geotechnical Lift Station Design PACE Engineer PACE Landau Associates r i asne Vince Follett Senior ' Electrical IEC Environmental Follett Engineering Specialist Landau Associates John McAlpine, P.E., Design Engineer Pipeline Design PACE City of Renton Design of Summerwind/Stonegate Lift Station Consolidation E Page 6 PROJECT TEAM MEMBERS PROJECT TEAM MEMBERS C1 - PROJECT TEAM MEMBERS PACE Engineers, Inc. (PACE) is an employee -owned company providing quality professional structural and civil engineering, planning, surveying, and construction management services from offices in Kirkland and Seattle, Washington and Oregon City, Oregon. We have successfully completed projects for a wide range of clients in both the public and private sectors throughout the Northwest. PACE offers an outstanding team to assist the City of Renton with the design of the Summerwind/Stonegate Lift Station Consolidation project. The PACE team brings together the required project management, lift station design, site civil design, electrical, survey, support services and other disciplines that will be essential for a successful project. PACE has extensive experience in wastewater lift station design and construction engineering. PACE staff have been responsible for over 100 different lift station projects throughout western Washington. Working with the City's staff and the public in providing mitigation and addressing other issues up -front is key to a successful project. We have team staff experience in all facets of lift station design from site planning, foundation, and structural design, screening, site security, piping control system, development of detailed plans and specifications, project estimating, permits, and environmental reviews. At PACE, we believe your project deserves our complete commitment. Our professional pride ensures that you receive the most responsive service possible. The key PACE team members whose talents are committed to this project are as follows. Martin L. Penhallegon, P.E., Principal -in -Charge. Marty Penhallegon has 35 years of consulting experience and is currently President and Principal -in -Charge of PACE. He was educated at the University of Washington, where he received a Bachelor of Science in Civil Engineering and completed post -graduate work in sanitary engineering. Marty has a diverse and interesting range of engineering experience, which includes all aspects of planning and engineering for municipal clients. As Engineer for a number of water and sewer purveyors, Marty has become fully aware of the problems and issues facing water utilities today. Project Role: Marty will personally oversee this project and be responsible for personnel assignments and quality assurance. Gareth A. Grube, P.E., Project Principal. Gareth has more than 35 years of experience in the field of consulting engineering including project management, facility design, and construction management. He has been responsible for the completion of projects involving site development; stormwater management; water distribution, transmission, and storage; wastewater collection and treatment systems; residuals management; and solid waste transfer and disposal. His project experience encompasses all aspects of public facility development, from planning through design, construction, and operations. Gareth's major emphasis has been in wastewater pumping and conveyance facilities. He has served as Project Manager for the design of pump station upgrades ranging in size from 35 gpm to 68 mgd, design of conveyance pipelines ranging up to 60" diameter, the addition of emergency generators at multiple pump stations, and retrofit of stations with confined spaces personnel access. He recently managed the design for the Point Edwards Lift Station for the City of Edmonds and Lift Station #36 Improvements for the City of Everett. Project Role: Gareth will serve as PACE's Project Manager. Dave Hutley, P.E., Sr. Project Manager. Dave has worked exclusively with utility purveyors for more than 20 years. His design and management experience with these municipalities has given him a broad City of Renton PACE Design of Summerwind/Stonegate Lift Station ConsolPa to n 9 I PROJECT TEAM MEMBERS understanding of design and construction of capital projects as well as the many related issues and constraints as well. As projects impact the public, a variety of complex problems are identified that require ' early and equitable resolution. Dave currently acts as the client engineer for several of our municipal clients and provides design and consultation not only on the larger projects but on the day-to-day engineering issues as well. Dave served as the PACE project manager for design of the Olympus Pump ' Station and the Upper May Creek Lift Station for the Coal Creek Utility District. Project Role: Dave will contribute to alternative analyses and will lead the lift station design subtask. ' John McAlpine, P.E., Design Engineer. John has 16 years of professional experience in civil and environmental engineering. His work experience includes facilities planning and design, project engineering during construction and contract administration for a wide variety of projects. John recently ' completed the design and construction for the International Boulevard Pipe Replacement and 161h Avenue Pipe Replacements projects for Midway Sewer District. Project Role: John will be the project design engineer for the interceptor improvements, and detailed project design coordination. David Fulton, P.L.S., Survey Manager will provide survey direction, should this be requested. David currently manages the Kirkland survey group and ensures that project work receives the required staff and resource support to meet the quality and time requirements. He has 19 years of experience and has been ' involved in many projects requiring GPS. David has factual and imaginative ways to apply GPS to real world applications at the same time reconfirming the importance of good survey techniques in every application. Project Role: David will be the Survey Manager. C2 - RELATED PROJECT EXPERIENCE PACE has worked with the City of Renton for a number of years. Recent projects for which we have provided services include engineering for the Elliot Avenue Bridge Sewer Design and survey for the Sunset ' Interceptor Sewer project. Projects that reflect our skills in lift station design include: ' Lift Station 36, City of Everett, Washington. The City of Everett operates a number wastewater lift stations serving several fast-growing areas near its southern limits that are nearing their capacities. Stepwise expansion of the system service area resulted in a sanitary sewer system that links pump stations ' in series with wastewater flowing through the stations via a roundabout route to the treatment plant absorbing system capacity along the way. Lift Station No. 24, downstream of the project area receives flow from LS No. 25 and LS No.36, and is currently nearing capacity. Alternatively capacity is currently ' available in the South End Interceptor, a 30-inch diameter conveyance pipeline northeast of the project areas. This project created design documents for diverting flow from a portion of the Lift Station No. 36 tributary area and Lift Station No. 25 to the South End Interceptor, thereby relieving pressure on the ' downstream portions of the system. ' The project included a study phase in which flow measurement and basin analysis were conducted and a series of pipeline routing and pumping alternatives were subjected to a life -cycle cost analysis. Following review by the City, a preferred alternative was selected and the resulting design was prepared and bid. The project is currently under construction and will be completed in 2006. Key Team Members: Gareth Grube, P. E., Project Manager City of Renton ' Design of Summerwind/Stonegate Lift Station Consolidation PACE Page 8 PROJECT TEAM MEMBERS 1 Point Edwards Lift Station, Triad Development, Edmonds, Washington. A developer constructed ' 300 high -value view condominiums on the Edmonds shoreline. In order to provide sewer service to the site, he was required to upgrade and enlarge an existing lift station owned by the City of Woodway and maintained by the Olympic View Water & Sewer District. Upon completion of construction, the station would become the property of the City of Edmonds. All work, therefore, would need to be completed to City of Edmonds standards. An existing casing under a heavily traveled state highway (SR 104) was re- used. This wet well/drywell station was constructed to replace an existing vacuum -primed package unit on a ' constrained site. The dry well fits into a single circular concrete structure below grade (including electrical and instrumentation). The station capacity is 300 gallons per minute against a head of 45 feet. An emergency generator and emergency storage tank are also included. A 1000 LF force main crosses under ' SR 104. The existing station was kept in service during the construction on the narrow site except for a carefully ' scheduled and monitored switchover. Site constraints included high seasonal groundwater, restricted staging areas, and sensitive neighbors. ' Vince Follett worked with PACE on the project and was responsible for design of all electrical systems: power, control, instrumentation and communications systems for the City of Edmonds Pt. Edwards WWPS. ' System electrical features included: • PLC control system for all equipment automatic operations ' New motor control center lineup for all power distribution and motor starters. • Heating, interior and site lighting, and ventilation power and controls. • New level control instrumentation in the wet well ' Telemetry communications via telephone for remote monitoring and alarm indication. • Standby generator and automatic transfer switch for automatic back up power. • Construction administration including inspection of all electrical installations and testing of ' all systems controls, alarming, interlocks and monitoring. Key Team Members: Gareth Grube, P. E., Project Manager, Vince Follett, Electrical Engineer ' Olympus Lift Station, Coal Creek Utility District, Newcastle, Washington. PACE prepared the design modifications to relocate and upsize Coal Creek Utility District's Olympus Pump Station. This station ' required relocation due to widening of Coal Creek Parkway, and was also upsized to accommodate build - out flows within its service area. The new custom -designed station is sized to handle flows of 2,500 gpm and includes three pumps, standby emergency power, a 100,000-gallon overflow wetwell, and state-of- the-art controls. The existing 8" forcemain was also upsized to 12" to handle increased flows. PACE conducted various hydraulic studies and models to simulate flow through this station. Key Team Members: Dave Hutley, P. E., Project Manager; John McAlpine, P. E., Project Engineer City of Renton ' Design of Summerwind/Stonegate Lift Station Consolidation PACE Page 9 PROJECT TEAM MEMBERS ' Wastewater Pump Station Upgrades Val Vue Sewer District, Tukwila Washington. Vince Follett was responsible for design of all electrical systems: power, control, instrumentation and communications ' systems for the Val Vue Sewer District. The project involved rebuilding three existing pump stations. Providing all new power and control systems and new standby generators. System design included: • Demolition of the existing control system and motor control center. • New control system for all equipment automatic operations • Integration of the new power system to the existing heating, interior and site lighting, and ' ventilation power and controls. • New level control instrumentation in the wet well • Telemetry communications via radio for remote monitoring and alarm indication. ' On site standby generator and automatic transfer switch. • Construction administration including inspection of all electrical installations and testing of all systems controls, alarming, interlocks and monitoring. ' Key Team Members. Dave Hutley, P.E., Project Manager International Boulevard Pipe Bursting, SeaTac, Washington. This project for the Val Vue Sewer ' District was required because the City of Seatac proposed widening International Blvd. The road widening incorporated a retaining wall in close proximity to Val Vue Sewer District's sewer main. The proposed wall would have blocked access to a sewer manhole. In addition, the old concrete main was in the zone of ' influence of the wall, with a possibility of the pipe settling or crushing. To solve the problem, PACE proposed installing a new sewer main by pipe bursting. The 8" HDPE line was pulled through the manhole to be abandoned. Due to the smooth interior of the high density pipe material, the grade change was ' accomplished without a manhole. The work proceeded with no impacts to the traveling public and a minimum of environmental disturbance. Key Team Members: John McAlpine, P. E., Project Manager ' Carkeek Pump Station, Seattle, Washington While this project is much larger than the project you anticipate, we include it because it represents a "high -head" condition, a situation that must be addressed in the design of the Kersey 3 lift station. The project addresses excessive flows discharged from King County's Carkeek CSO facility, which came on-line ' in 1995 to treat and discharge combined sewer overflows (CSO) to Puget Sound. The facility is meeting its permit discharge limits except for the volume of CSO discharged. The study included review of the City of Seattle's upstream system, King County's system upstream and downstream, the Carkeek Pump Station, ' and drainage issues in the watershed. The study was completed in June 2000. Recommendations included upgrading the pump station facility to ' 9.2 MGD capacity, and transferring more flow to West Point for treatment. Issues included the impact of further transfers on city and county CSO's at filth Avenue Northwest and the Ballard Siphon, and the impact of moving up the North Beach CSO project. Since the completion of the Task 200 study an ' independent expert in rotation equipment has evaluated the existing pumps to determine if they can be reused at a higher speed. PACE worked with King County staff to determine the suitability of the existing ' rotating equipment for reuse, and is currently preparing plans and specifications for both an equipment purchase contract and an installation contract for new flywheels and pump parts. Key Team Members. Gareth Grube, P. E., Project Manager City of Renton PACE Design of Summerwind/Stonegate Lift Station ConsPa eion 9 10 PROJECT TEAM MEMBERS 1 King County East Division Pump Station Upgrade, King County, Washington. System test ' engineer for power, Instrumentation and controls upgrade for three existing waste water pump stations. The pump station must first be transferred to a temporary power and control system and all system functions tested. The existing power and control systems are then demolished and new systems are ' installed and tested. The test engineer's responsibilities include writing detailed testing plan for verifying all control, monitoring and alarm systems functions, monitoring, and alarming and to witness and - supervise all system testing and transfer of equipment to the temporary and permanent control systems. ' Key Team Members. Vince Follett, Project Manager City of Edmonds Pump Stations 2 & 13; Edmonds, WA. Landau Associates provided geotechnical ' engineering services for the City of Edmonds' proposed Pump Station No. 2 Rehabilitation/Pump Station No. 13 Elimination project. Geotechnical engineering services include assessing site subsurface conditions at each project location and developing preliminary geotechnical conclusions and recommendations ' suitable to support the selection of a preferred design alternative for each project. Also evaluated the suitability of using trenchless construction methods to install the new force main for Pump Station No. 2 and the new gravity sewer for Pump Station No. 13. ' Key Team Members: Steven Wright, P. E., Project Manager C3 - SUB -CONSULTANTS ' We have selected several specialist sub -consultants to complete our team. These are firms whose professional approach has proven itself on numerous teaming efforts. ' Landau Associates - Geotechnical Engineer Landau Associates is a Pacific Northwest consulting firm, established in 1982. The firm specializes in geotechnical engineering, natural resources, and environmental engineering and science services. Their main office is located in Edmonds, Washington with other locations in Tacoma, Spokane, and Portland. ' Their geotechnical engineering services are typically performed to support site development or redevelopment, transportation, and infrastructure improvements. Their natural resources and environmental permitting services are provided in support of site and infrastructure development; ' permitting for waterfront and in -water repairs; stream and habitat restoration; and regulatory compliance with shoreline, fisheries, resource, and habitat issues. Landau Associates has worked on a number of projects directly for the City of Renton. Landau Associates staff members have conducted geotechnical investigations, hydrogeologic surveys, and environmental site assessments for the City of Renton in support of development or redevelopment of public facilities. Some of the firm's recent experience with the City of Renton includes the following: City of Renton Transfer Station Maintenance Facility — Geotechnical and Environmental Engineering Services City of Renton New Structure at Tiffany Park — Geotechnical Engineering Services City of Renton Craig Property (near SE Carr Road) — Phase I Environmental Site Assessment Services City of Renton Design of Summerwind/Stonegate Lift Station Consolidation PACE Page 11 PROJECT TEAM MEMBERS ' City of Renton Former Edlund Farm Property — Phase I Environmental Site Assessment and Focused Soil and Groundwater Sampling Services ' The firm's experience also includes dozens of lift station and sanitary sewer projects throughout the Puget Sound Region. Landau Associates has provided both geotechnical engineering and natural resource and ' permitting services for these projects from predesign through construction monitoring. The firm's recent geotechnical engineering services for lift stations have included seismic vulnerability assessments, developing recommendations related to open trenching, trenchless construction, construction on and ' adjacent to steep slopes and/or high groundwater, foundation support, excavation backfill and compaction, earth pressures on below -grade walls, buoyancy and uplift, and construction monitoring. Landau Associates also routinely provides natural resource services for lift station projects including addressing ' necessary permitting requirements (NEPA, SEPA, and DARPA), Endangered Species Act compliance, wetland delineation, cultural resource assessments, coordination with resource agencies, biological assessments and evaluations, and Essential Fish Habitat (EFH) evaluations. The following projects ' demonstrate Landau Associates' recent experience on lift station projects. • Skyway Water & Sewer - Geotechnical Services '0 City of Tukwila Strander Boulevard Stormwater Pump Station — Natural Resource, Permitting and Geotechnical Services • City of Olympia Percival Pump Station - Environmental Documentation, Geotechnical Engineering, ' and Wetland Delineation and Assessment Services • City of Mountlake Terrace Ridge Lift Station - Geotechnical Engineering Services • City of Edmonds Pump Station No. 2 Rehabilitation/Pump Station No. 13 Elimination Project — ' Preliminary Geotechnical Engineering Services • City of Tacoma — Hylebos Waterway Pump Station — Cultural Resource Technical Memorandum Services ' Steven Wright, P.E., Geotechnical Engineer. Project Role: Geotechnical Engineer, will be responsible for geotechnical design and specifications for the project. Steven will address all current codes and seismic design requirements. Sam Casne, Geotechnical Engineer. Project Role: Senior Environmental Specialist, will be responsible ' for environmental documentation and permitting services. Follett Engineering — Electrical Design, Instrumentation & Control Follett Engineering, PLLC provides electrical engineering design, consulting and construction management services as a sub -consultant to civil engineering firms and directly to municipalities for their projects involving water and wastewater facilities. ' Experience includes design and construction management of over 80 projects involving: water reservoirs, wastewater treatment plants, water treatment plants, wastewater pump stations, and water pump ' stations. Project design typically includes all phases of electrical design including power distribution, standby generators, automatic or manual transfer switches, motor control centers, VFD application, instrumentation, controls, communications, SCADA, and telemetry. Follett Engineering, PLLC strives to ' City of Renton Design of Summerwind/Stonegate Lift Station Consolidation PACE Page 12 PROJECT TEAM MEMBERS ' design power and control systems using modern technology while maintaining simplicity for easy operations and maintenance. PACE and Follett Engineering are currently working on five projects together. Vince Follett, Follett Engineering. Project Role: Provide detailed design for lift station electrical and ' supervisory controls. Mr. Follett has 19 years of experience in all aspects of design and construction management of power, controls, instrumentation and communications systems for water and wastewater facilities. Mr. Follett has managed and designed many projects involving instrumentation and control ' systems including hard -wired logic, PLCs, telemetry, HMI and SCADA system applications and design. Also, power system design, 12.47kV and 480-volt systems, motor control centers, VFDs, and emergency generation systems. City of Renton PACE Design of Summerwind/Stonegate Lift Station ConsPa eion 9 13 REFERENCES REFERENCES AND LIABILITY INSURANCE D - REFERENCES Referencesconcerning Client Contact Project City of Everett Ms. Jennifer Galatas, Project Lift Station #36 Manager, 425.257.7215 Coal Creek Utility District Tom Peadon, Manager, Olympus Lift Station 425.235.9200 Triad Development Mr. Ross Woods, Project Manager, Point Edwards Lift Station 206.617.7155 concerning Project Manager's Performance Client ContactReferences Project City of Everett Ms. Jennifer Galatas, Project Lift Station #36 Manager, 425.257.7215 City of Black Diamond Dan DalSanto, Public Works Water System Improvements Director, 360.886.2560 Triad Development Mr. Ross Woods, Project Manager, Point Edwards Lift Station 206.617.7155 ' E - LIABILITY INSURANCE PACE currently carries Errors and Omissions insurance in the amount of $2,000,000 per claim and in ' aggregate. PACE has never had an at -fault claim against our insurance. In those instances where issues come up that cause additional costs outside the ordinary care standard to occur, PACE will sit down with the client to discuss the situation and will simply make good on the costs. Situations resulting in costs ' beyond what we determine to be in our capacity to pay would be submitted to our insurance carrier. In any event, PACE has a history of owning up to mistakes and correcting the situation so that the client is not harmed. ' City of Renton Design of Summerwind/Stonegate Lift Station Consolidation rMVE Page 14 RESUMES I MARTIN L. EXPERIENCE PENHALLEGON, Marty has 35 years of experience in the design and management of major public works projects throughout the P.E. Northwest. As principal engineer for the 100-person President/Principal engineering and surveying firm, he oversees and is responsible Engineer for all work in the office. Marty has extensive experience in nearly every aspect of street, water, sewer, storm, and water quality engineering. Having this experience and knowledge EDUCATION and working for various municipalities and special purpose Bachelor of Science districts, Marty provides an insight that has proven invaluable University of Washington to our clients. His duties include promotion of the firm, client Seattle, Civil Engineering, liaison, and managing PACE's engineering, planning and 1971 drafting staff on major civil engineering projects. He has provided testimony at public meetings, council meetings, University of Washington meetings in support of various projects and has successfully Post Graduate Studies in assisted clients through the maze of permits required for Sanitary Engineering today's projects. REGISTRATION Shady Lake ULID, Cedar River water & Sewer District. Professional Engineer, Civil, PACE completed the design of a major sewer improvement Washington, 1976 system for the Shady Lake area. This project had been Professional Engineer, Civil, proposed for a number of years but costs were excessive for Oregon, 1986 local support. PACE devised a gravity design concept that resulted in projects costs that were acceptable to the PROFESSIONAL community and supported by nearly 90 percent of the property owners in the ULID. The design included two District -owned AFFILIATIONS pump stations and a gravity collection system circling Shady American Society of Civil Lake. Engineers American Water Works ULID 7S, Coal Creek Utility District. This was a $3.1 Association million project which was a very difficult local sewer Washington State improvement project. It involved the installation of sewers Association Water & through 64 private easements, through a project stabilized Wastewater slide area and on steep slopes. The work included design, Washington State Sewer & public participation, easement acquisition, environmental Water Association support and construction management, all accomplished by PACE. This project was funded by ULID assessment against the benefited properties. (PACE Upper May Creek Sewer Lift Station, Coal Creek Utility District. This is a regional sewer lift station intended to serve the majority of the south half of Coal Creek Utility District. It is a wet well/dry well station, approximately 26 feet deep with an initial capacity of 500 gpm. Future capacity upgrade to over 1,100 gpm can be achieved by simply changing out the pumps. The station included construction of over 4,000 lineal feet of 10" forcemain; an on -site generator housed in a building with an electrical/control room and storage area for the District's flush truck. Lower May Creek Sewer Improvements, Coal Creek Utility District. The Lower May Creek Sewer Improvements project is intended to provide sanitary sewer service to a MARTIN L. previously unsewered area within Coal Creek Utility District. It I PENHALLEGON consists of a lift station with 2400 feet of 6" force main and approximately 4800 lineal feet of 8" gravity sewer main. The P.E. new improvements will pick up existing dry sewers constructed ' Page Two in the 1970's that were originally intended to be connected to a King County/Metro interceptor, which has not been constructed. These general facilities will provide direct service to approximately 90 properties, but will eventually serve ' upwards of 300 lots in the southwest portion of the District. The project is being partially funded by a USDA Rural Development loan. PACE prepared the Federal loan application and will be providing all design and construction administration services on the project. 1 '11PAce GARETH EXPERIENCE GRUBS, P.E. Gareth has more than 30 years of experience in the field of Principal Engineer consulting engineering including project management, facility design, and construction management. He has been responsible for the completion of projects involving site EDUCATION development; stormwater management; water distribution, Bachelor of Science transmission, and storage; wastewater collection and University of Alaska, Civil treatment systems; residuals management; and solid waste Engineering, 1967 transfer and disposal. His project experience encompasses all Master of Science aspects of public facility development, from planning through University of Alaska, design, construction, and operations. Gareth has been Environmental Engineering, professionally licensed in the State of Washington since 1974. 1968 Gareth s professional career has been spent dealing with municipal agencies in the management and design arena. He is knowledgeable in agency policy, legal, and regulatory settings. REGISTRATION He is also familiar with planning and zoning regulations, Professional Engineer, Civil, building codes, guidelines and standards established by Washington, 1974 professional societies and organizations, state and federal Professional Engineer, Civil, mandates, and other regulatory requirements. Alaska, 1982 City of Everett, Lift Station #36, 2002. Gareth served as project manager for this project. The work included a basin PROFESSIONAL analysis, pump station evaluation, and creation of a hydraulic AFFILIATIONS model for a 500-acre drainage basin adjacent to Silver Lake American Public Works south of Everett. The design report considered alternatives Association aimed at transferring flows from the 1.2 mgd pump station American Water & away from an overloaded downstream station and diverting Wastewater them to a new force main. The new force main was Association constructed as part of highway improvements underway for SR Water Environment 527. The project required close coordination with the highway Federation design team to ensure that the pump station and force main were integrated and functional. Following approval of the design report, PACE was asked to prepare the necessary design for the lift station improvements including a detailed survey of an existing ductile iron force main that was to be converted from pressure flow to gravity flow. In this unique situation, calculation of pipeline capacity required a detailed topographic survey as well as non-destructive excavation at certain points along the existing alignment to confirm elevations for manhole design and installation. Point Edwards Wastewater Lift Station, (2004) Edmonds, Washington. This project reflects PACE's technical skill at meeting site and continuous service challenges for a wastewater facility as well as our ability to work with multiple agencies (private developer, two cities, and a wastewater district) to achieve a win -win outcome. The value of this contract was about $100,000. A developer constructed 300 high -value view condos on the Edmonds shoreline. In order to provide sewer service to the site, he was required to upgrade and enlarge an existing lift station owned by the City of Woodway and maintained by the (PAC J GARETH Olympic View Water & Sewer District. Upon completion of GRUBS P.E. construction, the station would become the property of the City of Edmonds. All work, therefore, would need to be completed Page Two to City of Edmonds standards. An existing casing under a heavily traveled state highway (SR 104) was re -used. This wet well/drywell station was constructed to replace an existing vacuum -primed package unit on a constrained site. The dry well fits into a single circular concrete structure below grade (including electrical and instrumentation). The station capacity is 300 gallons per minute against a head of 45 feet. An emergency generator and emergency storage tank are also included. A 1000 LF force main crosses under SR 104. The existing station was kept in service during the construction on the narrow site except for a carefully scheduled and monitored switchover. Site constraints included high seasonal groundwater, restricted staging areas, and sensitive neighbors. rPACE ) Everett Lift Station Assessment (2004) Everett, Washington. Gareth assisted the City of Everett in negotiations with a federal agency that desired to transfer operation and maintenance of 5 wastewater pump stations to the City. The stations ranged in size from small submersible stations at 150 gallons per minute up to complex wet well/dry well stations with 1200 gpm pumps. Specific work tasks included condition assessments of the facilities, maintenance record analysis, creation of a lift station standard for the City, and interviews with City operations personnel to ensure that operator concerns were addressed. York Pump Station, (1999) King County, Washington. As a part of the Blanket Services contract (below), Gareth managed the upgrade of the York Pump Station for the Wastewater Treatment Division increasing the capacity of the station to its 68 mgd capacity. The work involved adding new pumping equipment to recapture capacity lost during the original construction when excessive vibration caused the station to be de -rated. Blanket Services Contract, King County, Washington. (1997-2001) This project for the Wastewater Treatment Division of King County is a key example of his ability to meet client expectations and achieve a successful outcome. The blanket services contract involved more than 70 individual work orders and 20 specialized subconsultants, a complex leadership challenge with the potential for significant management headaches. To meet the challenge, early in the project Gareth developed a detailed plan for work order organization that addressed issues like project schedule and scope definition. By diligently applying this planning tool during the scope development phase of each work order and demanding clarity from project team members and other ' GARETH stakeholders on issues impacting scope, budget, and metrics GRUBS P.E. for success, he was able to deliver each work order on time, within its agreed -upon budget, and without unmet expectation. Page Three There were certainly management and technical challenges — ' staff changes, unexpected field conditions, reprioritization by upper -level management, budget limits, and technical risks, to name a few — but these were successfully met by personal commitment to client expectations, perseverance, and clear and frequent communication. Water System Improvements, City of Black Diamond, Washington. (2004-2006)Private development master plans have been proposed that would increase the population of the City of Black Diamond to more than 18,000 people over the next twenty years. Gareth has recently served as Project Manager helping the City meet this challenge. The current project involves siting and design of an intertie connection with the City of Tacoma system, a 4.3 million gallon storage reservoir, about 8,000 feet of new water pipe ranging up to 20-inches in diameter, a new pump station to deliver flow to the existing reservoir, and modifications at numerous points within the system to revise and improve the existing service pressure zones. The value of the improvements is estimated to be in excess of $5,000,000. The project is ongoing and will be completed in 2006. rPA�CE DAVE HUTLEY, P.E. Senior Project Manager EDUCATION ' Bachelor of Science Civil Engineering, 1983 Oregon State University REGISTRATION Professional Engineer, Civil, Washington, 1989 EXPERIENCE Dave has more than 21 years of municipal/public works experience. Although he has past experience in many facets of civil engineering, he has specialized over the past 18 years in utility planning, design and construction engineering. As an associate of PACE, Dave performs client liaison duties with a number of our municipal clients. He also performs his work assignments both as a principal engineer and a project manager depending on the client and project requirements. Dave provided sewer design and design review as District Engineer for various municipal sewer districts including Coal Creek Utility District, Cross Valley Water District, and Midway Sewer District. This work has included the design of more than a dozen lift stations and many miles of sanitary sewer improvements. His experience in utility planning and design is extensive as evidenced by the following sample list of some of his accomplishments. Coal Creek Utility District, Olympus Lift Station. Dave coordinated the preparation of the design modifications to relocate and upsize Coal Creek Utility District's Olympus Lift Station. This station required relocation due to widening of Coal Creek Parkway, and was also upsized to accommodate build -out flows within its service area. The new custom - designed station is sized to handle flows of 2,500 gpm and includes three pumps, standby emergency power, a 100,000- gallon overflow wetwell, and state-of-the-art controls. The existing 8" forcemain was also upsized to 12" to handle increased flows. PACE conducted various hydraulic studies and models to simulate flow through this station. Pump Station, Bryn Mawr-Lakeridge Water & Sewer District. Project Manager for the design of a new pump station intended to pump water from a new reservoir on the site to the District's two existing elevated reservoirs. The pump station consisted of a concrete building with metal roof, a three -pump domestic system, a 1,500 gpm fire pump and a diesel generator. The station was situated on a fairly steep site creating interesting foundation and site work designs. All mechanical elements of the pump station design were provided by PACE. Midway Sewer District, South 2601h Street Lift Station Upgrade. This project involved the design and installation of a new wet well and new electrical components at an existing lift station site. The improvements included a new 37-foot deep, 10-foot diameter wet well that had to be installed by drilling within an encasement due to space constraints. The soil conditions around the existing wet well provided an interesting challenge on this project, including the necessity to provide temporary pumping facilities to maintain service. The sloughing of existing sand backfill forced the removal of all DAVE HUTLEY, existing discharge piping. Alternate piping arrangements were P.E. made to discharge the sewer. Page Two Coal Creek Utility District, Lower May Creek/Windtree Sewer Improvements. This project, currently nearing the bidding phase, will provide sewer service to the southwest portion of Coal Creek Utility District's service area. It includes two submersible lift stations, 75 gpm and 500 gpm, approximately 300 feet of 3" force main, 2,800 feet of 6" force main and 4,000 feet of gravity sewer. Aspects of this project include preparation of plans and specifications in accordance with USDA Rural Development loan guidelines, a community involvement and notification program and the acquisition of various easements from residents and the City of Newcastle. The two lift stations and gravity facilities were designed to provide buildout capacity for the drainage basins they serve. Coal Creek Utility District, ULID 7S. This was a $3.1 million project which was a very difficult local sewer improvement project. It involved the installation of sewers through 64 private easements, through a project stabilized slide area and on steep slopes. The work included design, public participation, easement acquisition, environmental support and construction management, all accomplished by PACE. This project was funded by ULID assessment against the benefited properties. City of Issaquah, Sycamore Basin Sewer. As Project Manager, Dave worked on the design of approximately 11,000 feet of 8-inch PVC sewer main improvements in previously unsewered neighborhoods. The sewer design project included preparation of plans and specifications for sewers ranging from 8 to 17 feet deep, a dosing siphon and pipe boring across Issaquah Creek and approximately 22 individual lift stations for those properties lying too low to be served by gravity. Clearview Local Facilities Pump Station, Cross Valley Water District. PACE provided the design for this pump station, which is intended to provide water to the District from the Clearview Project, a joint project between Cross Valley Water District, Alderwood Water and Wastewater District and Silver Lake Water District. The station, a CMU building on an existing District standpipe site, houses three pumps with additional space for a fourth pump in the future. Also included in the design were provisions for a standby generator and alternate inlet piping to the existing standpipe to provide for better water turnover. The pump station is currently capable of providing 2,500 gpm to the District, with a future capacity of 4,500 gpm. ACE ) H JOHN M. McALPINE, P.E. Project Engineer EDUCATION Bachelor of Science Washington State University Civil Engineering, 1988 ' REGISTRATION Professional Engineer, Civil Washington, 1994 1 EXPERIENCE John McAlpine has more than 14 years of professional experience in civil and environmental engineering. His work experience includes facilities planning and design, project engineering during construction and contract administration for a wide variety of projects. John's design experience includes watermains ranging in size from 6 to 30-inch; pressure reducing valves, and pump stations. John has been the construction manager on several watermain improvements projects and has a strong field management background. His four years as a project engineer working for a water district provides a valuable asset in that John understands the day-to-day operation within a water district. SR96 - 8-Inch Water Main Replacement, Cross Valley Water District. Cross Valley Water District is replacing an existing 6-inch AC water main with a new 8-inch DI water main within SR96. PACE was contracted to obtain the WSDOT franchise permit and prepare plans and specifications. The permit was approved June 28, 2004. PACE prepared and submitted the 'Application for Utility Permit or Franchise' and 'Utility Facility Description' Permits. A traffic control plan was prepared and approved. PACE worked closely with the WSDOT Utility Accommodation Engineer to expedite the permit. Immediate approval was required to accommodate the District and an on -site contractor. Webster Lake Transmission Main, Cedar River Water and Sewer District. Prepared plans and specifications for 10,200 linear feet of 12-inch and 2,500 linear feet of 8-inch ductile iron watermain. Design included connection to two (2) existing reservoirs, one altitude value vault and watermain appurtenances. Low Pressure Area Improvements, Adlerwood Water and Wastewater District. John prepared plans and specifications for 2,800 LF of 8-inch, 8,400 LF of12-inch and 4,700 LF of 18-inch ductile iron watermain, Project entailed coordination with AWWD, WSDOT, Department of Fisheries, City of Everett and Snohomish County. Obtained franchise for jack and bore of 120 LF of steel casing under SR-522 and HPA for directional drilling of 14-inch HDPE under a salmon bearing stream. Design included connections to existing system, 80 single family PRV's and watermain appurtenances. 742 Booster Pump Station, City of Issaquah. Prepared plans and specifications for this pump station, intended to serve the Issaquah Highlands development. Design includes two 250 h.p. vertical turbine pumps each capable of conveying 1,425 gpm at 550 of head and one 500-gallon surge tank to control pressure transients within the 12-inch discharge line. Special design considerations were required to provide water to three different I 1 1 JOHN M. pressure zones. In addition, the design incorporates the ability to McALPINE, P.E. reverse flows through the pump station to lower pressure zones. Page Two Holly II Pump Station, City of Issaquah. Prepared plans and specifications for the City of Issaquah's Holly II Pump Station intended to convey flow to the 742 Booster Pump Station and 1000 pressure zone. The pump station is capable of conveying flows in the range of 300 gpm to a maximum of 3,800 gpm. Design includes 250 hp, 150 hp and 60 hp vertical turbine pumps and one 500-gallon surge tank. Special design considerations included the ability to work concurrently with the existing Holly I Pump Station to ensure all flow ranges are achieved. Combined Sewer Overflow Pump Station, City of Snohomish. Prepared preliminary and final plans and specifications for the CSO pump station. Prepared specifications for installation of pipe and construction of associated pump station. In addition, Mr. McAlpine prepared plans for the upsizing of approximately 1,000 feet of gravity sewer conveyed to the pump station. Duwamish Area Improvements, Val Vue Sewer District. Prepared plans and specifications for approximately 6,000 LF of 6- inch and 8-inch PVC sewer mains, 3,500 LF of 8-inch ductile iron watermain and one submersible sewage lift station. Project included the acquisition of a shoreline and Jarpa permit. Coordination for the project included the Department of Health, City of Tukwila and Department of Fisheries. 2001 Sewer and Storm Improvements, City of Bothell. Prepared plan and specifications for approximately 1,500 linear feet of 8" PVC sewer with manholes. In addition Mr. McAlpine designed 700 linear feet of 8" HDPE SDR-11 for directional drilling of an unstable hillside. 46th Avenue South Sewer Extension, Midway Sewer District. Prepared preliminary and final plans and specifications. Mr. McAlpine's work entailed the design of 2,400 feet of gravity sewer with manholes and side sewers. 24th Avenue South Sewer Relocation, Midway Sewer District. Prepared preliminary and final plans and specifications for the relocation of approximately 1,500 feet of gravity sewer. Work entailed raising and lowering existing manholes and new manholes and sewer lines. DAVID R. FULTON, P.L.S., ASSOCIATE Survey Manager EDUCATION ' Bachelor of Science Geology Utah State University, 1986 REGISTRATION Professional Land Surveyor 1 Washington, 1995 Professional Land Surveyor Idaho, 2001 1 L EXPERIENCE David Fulton has been involved with surveying for 17 years. In that time he has been involved with everything from large control networks and mapping projects to individual lot and hydrographic surveys. David has also been involved with GIS parcel and utility mapping projects delivering high accuracy geometry and utility data to various clients. David has been actively applying new survey procedures to utilize the full range of advances in GPS technology and to maximize the systems potential. Throughout his career David has been fortunate to have been involved with current advances in technology and is always open to new ideas and processes to aid in the ability provide quality survey products to clients. City of Issaquah, Intersection Improvements, East Lake Sammamish Parkway & SE 56"' Street. PACE surveyors were responsible for the mapping of 2000 feet of East Lake Sammamish Parkway up to six lanes wide and 1000 feet of SE 56"' Street also six lanes wide. The project was controlled by static GPS and conventional traverse survey methods. The survey included the locatable utilities and surface features plus wetland flags and a portion of the abandoned railroad grade now a trail. The main challenge on this project was defining the existing right of way. There were few monuments to measure from and discrepancies in the historical data. Bellevue Direct Access, Parsons Brinkerhoff Quade Douglas. Project surveyor for surveying and mapping the I- 405 corridor and surface streets through Bellevue. All utilities were added to the base map from field located lines and as - built records. The right-of-way and alignment lines were calculated for the ramps and main lines of I-405 as were the surface right-of-ways. The base map was done in the metric system and delivered in MicroStation. GPS was used to tie the project to NAD '83 '91 horizontal datum. Full width of adjoining right of ways and all utilities were included in the mapping. Sunnyhills Water Main Mapping, Sammamish Plateau Water & Sewer District. The project involved the full width right-of-way mapping of 24, 000 feet of roadway, through the suburban neighborhood located in the City of Sammamish. Project control was established from King County Survey points using Real Time Kinematic procedures. The field survey was accomplished using conventional total stations, which were used to radially survey the utilities, planimetric features and elevation changes. The field data was compiled using AutoCAD 14 and Softdesk 8, into a single base map depicting all of the elements of the field survey in a 3d model. DAVID R. Juanita Bay Pump Station and Forcemain, King County. FULTON P.L.S. PACE, as a sub to Brown and Caldwell, provided professional > > survey services for the design and development of a new ASSOCIATE sewer pump station and forcemain. The area covered by the ' Page Two project included the pump station site at NE Juanita Drive and 93rd Avenue NE, portions of Juanita Beach Park and a route running southerly and easterly to the sewer interceptor along the BNSF rail line at about Forbes Creek Drive and 111th Court ' NE for a total alignment of about 9500 feet. The project required significant research and recovery of monuments to define the right-of-way and boundaries of properties that may be affected by the pump station and conveyance structures. PACE is continuing to provide surveying services in the form of settlement monitoring throughout construction. Renton Sunset Interceptor, City of Renton. The project goal was to design a new sewer line along Sunset Blvd. The mapping covered the full right-of-way of 12,000 feet of Sunset Blvd. and intersecting streets. The project control was tied to City of Renton Survey Control Points by conventional traverse methods. The utilities along the route were located and the field survey followed, locating the physical features, grade changes and utility structures. The base map showed the surveyed features, boundaries, tax parcel number and owners name. LJ t—J �1 F� STEVEN WRIGHT, P.E. Senior Associate Expertise Steve brings 19 years of experience conducting geotechnical investigations and Geotechnical Engineering providing related solutions throughout the Pacific Northwest. His project Geologic Hazards experience includes conducting geotechnical investigations and providing during - Construction Oversight construction monitoring and problem solving for buildings, bridges, roadways, transit facilities, waterfront structures, underground utilities, and large commercial, industrial, and residential land development projects. Steve's experience also includes providing geotechnical engineering design for residential and industrial redevelopment projects and preparing the earth section of programmatic and project specific Environmental Impact Statements. City of Renton Corrosion Control Treatment Facilities; Renton, WA. Provided geotechnical engineering recommendations for the design of two separate corrosion control treatment facilities that were constructed to reduce corrosivity of groundwater from the City's Downtown Wellfield and artesian spring water from Springbrook Springs. Tasks included reviewing available geotechnical and geologic data for the area in the vicinity of the proposed sites and performing a geotechnical reconnaissance of each site. Based on the results of the geotechnical reconnaissance, literature review, and engineering analyses performed, geotechnical engineering recommendations pertaining to site preparation and earthwork, foundation support, concrete slab -on -grade floors, underground utilities, below -grade detention vaults, pavements, and site drainage and erosion control were provided. City of Edmonds Pump Stations 2 & 13; Edmonds, WA. Project manager overseeing preliminary geotechnical engineering services for the City of Edmonds' proposed Pump Station No. 2 Rehabilitation/Pump Station No. 13 Elimination project. Geotechnical engineering services include assessing site subsurface conditions at each project location and developing preliminary geotechnical conclusions and recommendations suitable to support the selection of a preferred design alternative for each project. Also evaluated the suitability of using trenchless construction methods to install the new force main for Pump Station No. 2 and the new gravity sewer for Pump Station No. 13. Crownwood Lift Station Replacement; Port Orchard, WA. Project manager responsible for providing geotechnical field and laboratory testing services for the Karcher Creek Sewer District's proposed Crownwood Lift Station Replacement project in Port Orchard, Washington. The new lift station, which will be founded about 16 ft below existing grades, will be about 10 ft by 10 ft in plan dimension. Services provided included advancing an exploratory boring within the area of the new lift station, recording observed subsurface soil and groundwater conditions, conducting limited laboratory testing, and submitting a letter report summarizing the results of the geotechnical field and laboratory testing services that were performed. Terrace Ridge Lift Station Replacement; Mountlake Terrace, WA. Project manager for a geotechnical engineering study conducted in support of the design of the City of Mountlake Terrace's proposed Terrace Ridge Lift Station Replacement project. The new lift station, which will be founded about 15 ft below existing grades, will include a 4- to 6-ft diameter wet well and a 9-ft diameter steel package station. Scope of services provided included advancing an exploratory boring within the area of the new lift station, conducting laboratory testing, and developing conclusions and specific geotechnical engineering recommendations regarding foundation support, excavation backfill and compaction criteria, earth. pressures on below -grade walls, buoyancy and uplift, and construction monitoring. L.I.D. No. 3 Sanitary Sewer Improvement Project; Pacific, WA. Geotechnical engineer responsible for conducting a geotechnical engineering study and providing geotechnical engineering recommendations for the construction of a 25-foot deep lift station, installation of new manholes, and the installation of about 120,000 lineal feet of gravity sewers and force mains. Performed engineering evaluations and provided geotechnical recommendations related to the use of lightweight trench backfill to mitigate settlement of new pipelines located above deep peat deposits that were not practical to remove. Also developed recommendations related to excavation and temporary shoring, dewatering, pipe bedding and support, trench backfill, buoyancy and uplift, pavement restoration, and wet weather earthwork. Allentown Water and Sewer Replacement Project; Tukwila, WA. Geotechnical engineer responsible for conducting a subsurface investigation and providing geotechnical engineering recommendations for the installation of new water and sewer lines, and a lift station. Performed engineering evaluations and provided geotechnical recommendations related to pipe bedding and support, trench backfill, excavation shoring, and dewatering. Also provided pavement design recommendations for the reconstruction of the streets along the project alignment. South Interceptor Parallel, Phase II; Renton, WA. Project engineer responsible for conducting a geotechnical investigation for the installation of about 4,200 feet of 108-inch diameter pre -cast concrete pipe, with invert elevations approximately 18 to 20 feet below the ground surface. Performed geotechnical engineering evaluations and provided recommendations related to pipe bedding and support, trench backfill, and earth pressures on buried pipes. Also provided recommendations related to excavation shoring, site seismicity and liquefaction potential, dewatering, and pipe jacking at a creek and railroad under -crossing. Renton Transit Center Expansion; Renton, WA. Project manager responsible for conducting a geotechnical investigation related to the expansion of the temporary Renton Transit Center facility. The project consisted of constructing a permanent two-way transit facility on Burnett Avenue and a new transit -only road mid -block between Logan Avenue South and Burnett Avenue South. New parking areas and passenger loading platforms were proposed on either side of the new transit -only road. Provided recommendations related to site preparation and earthwork, concrete slabs -on -grade, structural pavement design, underground utilities, and site drainage requirements. Mount Vernon Wastewater Treatment Plant Improvements; Mount Vernon, WA. Project engineer for pre -design level geotechnical engineering services for the proposed improvements at the Mount Vernon WWTP. The WWTP improvements included a new influent pump station and pipeline, primary clarifiers, aeration basins, dissolved air floatation thickener, and digester structures. Services provided included collecting and reviewing existing geotechnical data for the project area, conducting a geotechnical investigation and laboratory testing program to further characterize subsurface soil and groundwater conditions at the proposed structure locations, conducting engineering analyses, and providing pre - design geotechnical engineering recommendations related to site preparation and earthwork, temporary excavation shoring and dewatering, a combined excavation shoring and groundwater cutoff wall for the deep influent pump station, site surcharging, seismic design considerations, buoyancy and uplift considerations, and foundation support for the planned structures Education B.S., Civil Engineering, University of Washington, 1987 Registrations/ Professional Engineer (Civil): 1995/Washington (#32250) Certifications SAM CASNE Senior Associate Expertise Sam, a senior associate in the Natural Resource Group, has 30 years of experience Environmental Documentation in fisheries, wetlands, permitting, and natural resource management. He has five ' Threatened Endangered years experience with King County Surface Water Management where he managed the environmental aspects of numerous surface water CIP's, and 10 years Species Studies udies experience with the Regulatory Branch at the Seattle District Corps of Engineers Salmon Habitat Evaluation where he analyzed permit applications for impacts to the aquatic environment. ' Permitting Sam has worked as a consultant assisting clients with endangered species studies, Wetland Delineation stream restoration design, stream habitat and classification studies, wetland Stream & Wetland delineation, wetland inventories, and project permitting. His experience includes Mitigation/Restoration stream restoration in conjunction with stormwater management projects. Sam has ' Resource Agency Coordination prepared numerous biological assessments (BAs) for projects that required compliance with the Endangered Species Act. Strander Boulevard Stormwater Pump Station; Tukwila, WA. Project manager for environmental documentation and permitting services for the City of Tukwila Strander Boulevard Stormwater Pump Station design. This project will replace 1200 linear feet of inefficient stormwater conveyance and design a pump station to pump stormwater into the Green River to eliminate flooding of Strander Boulevard. Sam coordinated with resource agency biologists during the design of ' the outfall to determine mitigation requirements for the project. He prepared the DARPA for the federal and state permits for the new outfall into the Green River and managed application for all environmental permits required for the project. He prepared the Biological Evaluation (BE) and the Essential Fish Habitat (EFH) evaluation for compliance with the Endangered Species Act and the Magnuson - Stevens Act. The Corps of Engineers agreed with the findings of the BE and ' conducted Section 7 consultation with the "Services." The Services agreed with Sam's determinations and the Corps issued the required Section 404 permit. Sam also coordinated with Washington State Department of Ecology to assure that the project met their requirements for the water quality certification. When completed, this project will eliminate flooding of Strander Boulevard and the unsafe and hazardous driving conditions during storm events. City of Olympia Percival Pump Station; Olympia, WA. Senior Biologist for ' environmental documentation and permitting a new potable water pump station in Percival Cove, Olympia. Reviewed alternatives that included new water lines parallel and crossing Percival Creek as well as several wetlands. Worked with project engineers to develop an alterative that would minimize impacts to Percival Creek and wetlands, thus reducing lengthy and expensive permitting and environmental documentation. The preferred alternative for the new line will follow existing streets. Prepared SEPA checklist and Corps nationwide permit for utility crossing over navigable waters (Percival Cove) and City of Olympia ' Shoreline permit. Bayview Community Sewer Extension, Birch Bay Water & Sewer District; Blaine, WA. Task manager for preparation of an Effects Determination ' (ED) and EFH evaluation for the federally funded sewer extension project. The analyses were required to gain compliance with the ESA and the Magnuson - Stevens Act. The project included extension of a sewer line to 171 residential lots in the Bayview community that were on septic systems. Mr. Casne concluded that the project would have no effect on listed species and would not adversely affect essential fish habitat. When the federal reviewing agencies concur with the determinations, the federal funds can be released and the project constructed. This ' will eliminate the ecological and human health problems of 171 residential lots on failing septic systems. ' City -Wide Sewer System - Natural Resource Inventory; Carnation, WA. Task manager for a Biological Assessment (BA) and Essential Fish Habitat (EFH) Evaluation of the vacuum system to determine impacts of the project on threatened and endangered species for a citywide sanitary sewer vacuum conveyance sewer system. While the BA detailed project impacts on Puget Sound chinook salmon, bull trout, and bald eagle, other species considered were gray wolf, Canada lynx, ' Northern spotted owl, grizzly bear, and marbled murrelet. The BA also discussed project impacts on proposed critical habitat for bull trout. The BA concluded the project will have "no effect" on listed species or their proposed critical habitat. ' The EFH discussed impacts on Pacific salmon habitat and concluded no adverse effects. These studies will allow the City to obtain the funding to construct the vacuum system in conjunction with the proposed new treatment plant being designed by King County. This will allow residents and business in Carnation to ' convert from the existing septic systems onto the new sewer system and help the City of Carnation meet the requirements of the Growth Management Act. Environmental Documentation, King County I/I Studies; King County, WA. Senior manager responsible for assisting project team and King County in determining environmental documentation required for potential projects proposed by the King County infiltration and inflow study. Projects included several alternatives throughout King County designed as pilot studies to determine the feasibility of several options to reduce infiltration and inflow into wastewater systems. Assisted King County with SEPA evaluation, Endangered Species Act compliance, and identification of permit requirements for the projects. Additional flow studies were required to determine which projects would be carried forward to ' design and construction. North Stream Storm Repair; Edmonds, WA. Project biologist responsible for evaluating several alternatives for culvert replacement on Northstream in Edmonds ' and advised design engineer as to permitting and environmental documentation required for each alternative. Conducted stream survey to determine fish habitat and prepared critical habitat stream report per local Critical Areas Ordinance Requirements. Evaluated project impacts on species listed under the ESA. ' Preferred alternative included directional trenchless techniques in the dry to avoid lengthy permit procedures and the project will be permitted by a Corps of Engineers nationwide permit. ' Biological Assessments; King County, WA. Program manager for the King County Department of Natural Resources on -call environmental and professional services contact. Managed the preparation of two Biological Assessments (BAs) under the Endangered Species Act. One BA addressed the impacts of a new storm ' drain outfall from street drainage improvements. The outfall is into the Snoqualmie River in the town of Snoqualmie. The primary species addressed in the BA were bull trout, and Puget Sound chinook salmon. The second BA was for ' a culvert replacement at the confluence of Gold Creek and the Sammamish River in King County. Species addressed in the BA were chinook salmon, bull trout and bald eagle. These BA's satisfied the requirements of the National Marine Fisheries Services and the U.S. Fish & Wildlife Services, which allowed the county to construct the projects. Education M.S., Fisheries Science, University of Washington, 1975 B.S., Mathematics, Montana State University, 1968 FOLLETT ENGINEERING. PLLC ' ELECTRICAL ENGINEERING & CONSULTING 23316 NE Redmond -Fall Cite Rd 4602 Redmond, WA 48053-8376 Office: 425-836-3333 Mobile: 425-765-6304 Fax: 425-836-5517 E-mail VincevFollettEngincering.com II FIRM PROFILE • Water Facilities Design • Waste Water Facilities Design • Power distribution systems • Raceway systems • Switchgear • Motor Control Centers • Standby Generators • VFD Applications • Control Systems • PLC Control • Telemetry Systems • SCADA • Process Control • Instrumentation Systems • Fire Alarm Systems • Lighting Systems Follett Engineering, PLLC provides electrical engineering design, consulting and construction management services as a sub -consultant to civil engineering firms and directly to municipalities for their projects involving water and wastewater facilities. Experience includes design and construction management of over 100 projects involving: wastewater treatment plants, water treatment plants, wastewater pump stations, water pump stations, & water reservoirs. Project design typically includes all phases of electrical design including power distribution, standby generators, automatic or manual transfer switches, motor control centers, VFD application, instrumentation, controls, communications, SCADA, and telemetry. Follett Engineering, PLLC strives to design power and control systems using modern technology while maintaining simplicity for easy operations and maintenance. Follett Engineering, PLLC is registered as an SEDB under King County's Contracting Opportunities Program. Certification number is: 454. Follett Engineering, PLLC is a licensed Washington Engineering Company (LIBI 602-174-602). Tax identification number is 73-1625544 I FOLLETT ENGINEERING, PLLC ELECTRICAL ENGINEERING & CONSULTING 23316 NE Redmond -Fall Cite Rd #602 Redmond, WA 98053-8376 Office: 425-836-3333 Mobile: 425-765-6304 Fax: 425-836-5517 E-mail Vinceii'.FollettEngineering.com VINCENT M. FOLLETT, P.E. PRESIDENT Education: Bachelor of Science - Electrical Engineering (Power Systems Emphasis) University of Washington, Seattle, Washington - Awarded June 1985 Professional Licenses Professional Electrical Engineer - February 1988 - Washington, Oregon, California Journeyman Plumber - July 1983 Project Experience: Responsible for the power and control systems design, project management and construction management for: • 11 new waste water treatment plants (full design of all power and I&C systems). • 5 MBR waste water treatment plants (full design of all power and I&C systems) • 9 major upgrades to waste water treatment plants. • 29 waste water pump stations (up to 500 hp). • 13 water treatment plants (filtration and chemical treatment) • 10 water reservoirs. • 28 water pump stations and wells (up to 500 hp). • 2 major fire alarm systems. • 35 projects with emergency generators up to 2,000KW. • 24 projects with variable frequency drives (VFDs). • 19 projects with chemical treatment, sodium hydroxide, hypochlorite, gaseous chlorine, sulfur dioxide, fluoride. • 39 projects with telemetry systems. • 33 projects with PLCs. • 9 projects with full SCADA system designs. Summary of Professional Experience: Mr. Follett has over 20 years of experience in all aspects of design and construction management of power, controls, instrumentation and communications systems for water and wastewater facilities. Mr. Follett has managed and designed many projects involving instrumentation and control systems including hard wired logic, PLCs, telemetry, HMI and SCADA system applications and design. Also, power system design, 12.47kV and 480-volt systems, motor control centers, VFDs, and emergency generation systems. ' Mr. Follett is experienced in design of both water and wastewater treatment processes: primary and secondary treatment and solids handling. Extensive experience in project management including major design projects and coordination with Civil, mechanical, and ' architectural disciplines; Including construction supervision and field support services, problem diagnosis, and system testing. References: • Jim Konigsfeld — Lead Engineer — Sammamish Plateau Water and Sewer District — 425-392-7807 x217. • Kirk Hunkeler — Field Superintendent, Cedar River Water & Sewer District - 425-255-6370 • Vicky Epp — Lead Engineer — Firgrove Mutual Water Company — 253-845-1542 • Steve Brewer, Chief Operator — Stevens Pass WWTP 360-973-2804 • Dana Dick — District Manager- Valvue Sewer District 206-255-2473 Relevant project experience LOTT — Satellite MBR WWTP Brian Topolski PE - Engr. Manager — LOTT 360-753-8386 Completion Date: Current Mr. Follett was responsible for design of all electrical power system and associated controls systems for a 1 MGD membrane bioreactor wastewater treatment plant. The purpose of the satellite plant is to take raw waste water from LOTT's Martin Way Pump station and treat the water for re -use by commercial customers and for ground water recharge. The system design included: • a 2500 amp 480volt, 3 phase utility service and a 1250 kW standby generator with automatic transfer switch. • Motor control centers and equipment communications via Device -net. • VFD's up to 250 horse power, all VFDs over 50 hp provided as 18 pulse to mitigate harmonics. • Instrumentation for flow, pressure, level, dissolved oxygen, and turbidity • Hazardous area classification and design issues • In plant SCADA system • PLC control with Ethernet communications. Stevens Pass MBR WWTP Owner/Contact: Steve Brewer, Chief Operator — Stevens Pass WWTP 360-973-2804 Completion Date: September 2005 Mr. Follett was responsible for design of all electrical power, control, instrumentation and communications system and associated controls systems for a 200,000 gallon per day membrane bioreactor wastewater treatment plant for the Stevens Pass Resort. The purpose of the project was to provide a very high quality water for the WWTP discharge to a small creek. The MBR system manufacturer for this project is US Filter. The project design and construction included: ' • An 800 amp 480volt, 3 phase utility service and a 250 kW standby generator with a closed transition automatic transfer switch. • Motor control centers and equipment ' • 18 motors with VFD's and harmonic mitigations techniques. • Instrumentation for flow, pressure, level, dissolved oxygen, and turbidity Hazardous are classification and design issues ' • In plant SCADA system • 3 PI -Cs networked via Ethernet communications. ' Telemetry system with radio repeater for communications to the remote flow equalization basin site. • Remote access system configuration for operations and monitoring of plant from any remote dial in location. • Follett Engineering in coordination with Evolution Controls also provided PLC programming of all systems outside of the US Filter system and provided all SCADA and communications system programming and operator interface programming for the project. • Construction administration including inspection of all electrical installations and ' testing of all systems controls, alarming, interlocks and monitoring. Lummi Nation MBR WWTP ' Owner/Contact: Bill McCourt 360-758-7167 Completion Date: Current Mr. Follett was responsible for design of all electrical power, control, instrumentation and ' communications system and associated controls systems for a 200,000 gallon per day membrane bioreactor wastewater treatment plant for the Lummi Nation. The purpose of the project is to provide waste water treatment for a new casino and for the north part of the district. The plant will also be used as a teaching facility at the school that is being built at the same site. The MBR system manufacturer for this project is Kubota: ' • A 600 amp 480volt, 3 phase utility service and a 200 kW standby generator with a closed transition automatic transfer switch. • Motor control centers and equipment ' 8 motors with VFD's and harmonic mitigations techniques. • Instrumentation for flow, pressure, level, dissolved oxygen, and turbidity • Hazardous area classification and design issues 1 In plant SCADA system • 2 PI -Cs networked via Ethernet communications. ' • Headquarters SCADA system for future communications and control for the districts water system and monitoring of the waste water pump stations. • Telemetry system with radio communications ' • Remote access system configuration for operations and monitoring of plant from any remote dial in location. • Follett Engineering in coordination with Evolution Controls will also provide PLC ' programming of all systems outside of the Kubota system and provided all SCADA and communications system programming and operator interface programming for the project. ' Sammamish Plateau Water & Sewer District Well 2 & Chemical Treatment ' Owner/Contact: Jim Konigsfeld — Lead Engineer — Sammamish Plateau Water and Sewer District — 425-392-7807 x217. Completion Date. November 2004 ' Mr. Follett was responsible for design of all electrical control, instrumentation and communications systems for a chemical treatment facility for two wells. Chemical treatment included sodium hydroxide for pH control, filtration system for iron and ' manganese removal. Also include is an on site hypo -chlorite generation system and chemical feed pumps for disinfection. The system design included: • 480V, 3 phase power service with Kirk -key interlocked manual transfer switch for ' connection of a portable generator. • Motor control center with solid state "soft" starters for the two well pumps • Deep well pump controls integrated with waste and line control valves. • Chemical feed pump controls for addition of hypo chlorite and sodium -hydroxide • Monitoring and control of the iron/manganese filtration system. ' • Control system for dilution of 50% sodium hydroxide to 25% solution in day tank. System includes level monitoring of 50% and 25% sodium hydroxide tanks magnetic flow meters for monitoring and control. ' • Integrated telemetry system for monitoring and control of the station from the district office. • Backwash pump station power and controls ' • Heating, interior and site lighting, and ventilation power and controls. • Follett Engineering in coordination with Evolution Controls also provided all PLC and operator interface programming for the project. ' Construction administration including inspection of all electrical installations and testing of all systems controls, alarming, interlocks and monitoring. TETRA TECH KCM, INC. December 12, 2006 ' David Christensen Wastewater Utility Engineering Section, 5th Floor City of Renton 1055 South Grady Way Renton, WA 98055 Subject: Proposal for Summerwind/Stonegate Lift Station Consolidation and Field Avenue Interceptor Dear Dave: ' We are pleased to provide the attached proposal for engineering services for the City's planned sewer project in the Summerwind and Stonegate neighborhoods. ' We've assembled a project team that fits this project well. Kevin Goss will be the project manager. He managed the predesign portion of the Sunset Interceptor, Phase 3 which studied sewer routing for these basins and recommended diverting portions of Summerwind and Stonegate flows to Field Avenue. ' He and I are working together on a lift station for the City of Mercer Island with many similarities to this one. It is a submersible station in a high -end residential neighborhood next to a sensitive area (shoreline). It has a small, detached building housing the electrical and control panels as well as a standby generator. ' We've rounded out the team with subconsultants based upon their past successful work for the City of Renton and upon our own recent work with them. Many of them are currently working with us on the Mercer Island project, which is scheduled to advertise in February. We will apply the working relationships and knowledge developed there to your project. Thank you for your time in discussing this project with us. We hope we have demonstrated that we are the best team ' to complete this project and that you will award it to us. Sincerely, ' ;TeTech, Ipc. ykken, P.E. pal KRG: kg.8730001 KCM, Inc. c1ba Tetra Tech/KCM, Inc 1420 Fifth Avenue, Suite 600, Seattle, WA 98101 Tel 206.883.9300 Fax 206.883-9301 A. PROJECT APPROACH Tetra Tech has assembled a project team with a clear understanding of the project background, the experience to ask the right questions throughout design, and established working relationships amongst the team members. Our proposed Project Manager, Kevin Goss, managed the predesign portion of the Sunset Interceptor, Phase 3, which recommended the flow diversions sought under the current request for proposals. We expect to be able to engage City staff on key project issues on day one and efficiently guide the project forward through design and construction. Alternatives Analysis The preliminary engineering report for Phase 3 of the Sunset Interceptor took a comprehensive look at sewer service routes in the basins tributary to the Sunset Interceptor. It recommended diverting flows away from Duvall Ave in order to preserve the capacity of that sewer. A significant and growing portion of these flows come from the north and east sides of the Plat of Summerwind, from the Plat of Stonegate, and from newer developments upstream of Stonegate. The current project would collect all of these flows at a new lift station adjacent to the existing Stonegate lift station and build a new force main to Field Avenue, allowing the abandonment of the existing Summerwind and Stonegate lift stations. A new gravity sewer on Field Avenue would convey the flows to Sunset Boulevard. The existing Sunset system would be upsized as far west as the new sewer built at the intersection of Sunset Boulevard and Duvall Avenue. This reconfigured system would carry flows from the currently developing areas inside the Urban Growth Boundary, and in the future from other areas within the gravity basin served by the new Stonegate lift station. The system would be sized for build -out of the logical service basin based upon City planning criteria. Within this proposed basin, there are still alternatives to be considered for the most serviceable and cost-effective system configuration. Consideration should be given to: * Existing system configuration and capacity relative to anticipated growth patterns. * Diversion of upstream service areas away from current routes if capacity is preserved and cost is saved. * Proximity of new construction to existing utilities. * Availability of space within existing roadways and easements for both existing and proposed pipelines. * Reduction of typical water/sewer separation requirements based upon construction materials and methods. * Impact to existing easement areas and number of times entry is required to accomplish the required work. * Alternative alignments of the force main between the new Stonegate lift station and the high point on Field Avenue that address the above complexities. Use of the existing City -owned emergency access tract between the Plats of Summerwind and Stonegate is one alternative. * Maintaining public and emergency vehicle access to all properties throughout construction. During roadway construction in Stonegate, it may be possible to utilize the existing emergency access driveway to Summerwind during the daytime for local access, and close it at night when the roadway is reopened. City of Renton TETRA TECH, INC. 1 * A dedicated bypass sewer on Field Avenue in lieu of reconstructing the existing gravity system to handle higher flows. A bypass would be smaller and shallower and would not require reconnection of side sewers. It would be much faster to build and have much less impact on the neighborhood. * Sensitive areas and permitting implications of alternative alignments. * Pump Station and supporting equipment configuration, to the extent that some elements (such as an above -grade control/generator building) could be impacted by sensitive areas, permitting requirements, or by strong public opposition. The alternatives analysis is a collaborative effort with the City's staff. The final report establishes a record of the alternatives considered and choices made by the team. City staff will help define and confirm the alternatives to be studied and will help narrow the choices prior to preparation of a final recommendation. Design of the Project Tract A FE11A 1wy.1 LEGEND F�ooepam�\ --tic" LEGEND • Existing Gravity Sewer • Existing Force Main Existir g — construct Maw . vsF- • Existing Manhole Lift gate Lirt Station Existing Lift Station Proposed Improvement Abandon Proposed NE 2W S. Proposed Gravity SewSummerwind Gravityer Lm Station Sewer - - - + Proposed Force Main 1' NE ST W2i�st i �m NE 21.1 ST. i �7 Discharge to f / NE21stQ Gravity Manhole 1�" NE 2qh St / Possible Face Main Proposed Shallow Alignment Gravity Bypass for Stonegale Discharge < Leave Existirg ravity and S' Sewers on gE flth sr. Field Avenue in Place N "E "08106 # >w 3W Proposed Upsizedd ter. 1•.Iw Gravity Interceptor ICommunity Meetings The proposed project will impact local residents and will require entry to private property in limited areas. A limited public involvement campaign will allow the City to explain the upcoming work to interested residents. It may be appropriate to send a mailing and hold a public open -house following the alternatives evaluation. Such activity would notify residents of upcoming survey and geotechnical work, help explain the types of impacts to be expected, and provide contact information. Mailings and/or web page updates will allow interested parties to follow the progress of the project. We do not propose to use a public involvement subconsultant on this project. We feel we can supplement the efforts of City staff to implement a public involvement campaign that will help reduce the impacts this project will have on the neighborhoods. Topographic Survey A topographic survey is necessary to collect existing site data prior to design. In general, there is enough information available from as-builts and existing mapping to conduct the alternatives analysis without a complete topo survey. It may be appropriate to supplement this on a limited basis with information on sensitive areas. The bulk of the topographic survey can likely be deferred until the alignment is settled, which will eliminate wasted survey effort. TETRA TECH, INC. 2 City of Renton ' ' Geotechnical Analysis Geotechnical exploration and analyses are needed to prepare project plans and opinions of probable construction ' cost that are appropriate for actual site conditions. Unless the assessment of existing geotechnical data suggests that soil conditions may vary significantly between alternative alignments, geotechnical field exploration can be deferred until the alignment is settled, which will eliminate wasted effort. To assess subsurface soil conditions, 4WA Geosciences nticipates drilling ten borings to depths of between 10 and 15 feet. One additional boring at the proposed i site would extend 5 to 10 feet below the bottom of the proposed structure. Along Sunset Avenue NE, the boring information obtained previously by HWA for the Sunset ' Interceptor Phase III Improvement project will be used. Standpipe piezometers will be installed at five locations to determine and monitor ground water levels along the alignment and at the new lift station location. ' There is the possibility that portions of the project work may occur within or near steep slopes that exceed height exemptions from critical areas regulations. If so, the impacts of the proposed construction will be assessed and specific design recommendations will be developed as appropriate for both the contract and project permitting. The new gravity sewer downstream from the existing Summerwind lift station will be partially within the berm of the existing detention facility. Reconstruction of the berm must maintain its structural and water -tight integrity in order to safeguard not only the pond itself, but downstream homes and utilities. There may be permitting implications to construction within this embankment. ' Where only force main and shallow gravity bypass pipeline are being constructed, it may be appropriate to eliminate or significantly reduce the extent of geotechnical exploration. In areas where differential settlement would not effect ' system performance, the cost of the geotechnical exploration and analyses may be better spent on contingencies for foundation gravel or restrained joint pipe. Civil / Structural / Mechanical / Architectural Design ' Tetra Tech staff will prepare: plan, profile, elevation, and detail drawings; specifications; and opinions of probable construction cost for pipelines, the lift station site, buried lift station facilities, and an above -grade electricallgenerator building. Structural design will likely in nts to the extent they are ' appropriate for the project. hamcal design will ased upon existing City standar out for submersible PUMP stations. Architectural a fnc y mto tfighborhood. Electrical / Control / Telemetry Design Electrical and controls design will include the development of plans, details, one -line diagrams, calculations and schedules, and control panel configurations. To the extent practical and as the City desires, we would re -use electrical installation details that have been used on previous City lift station projects to help reduce design cost and to increase maintenance consistency ama facilities. The telemetry design will include final coordination with the City's preferred telemetr sup lier (TS ther tasks include coordination with Puget Sound Energy for the installation of -a- new a ectrical service adequate to serve the station. ' Easements The project will impact the local residents during construction. The City already has an easement for the likely ' gravity sewer route. It appears that the possible force main alignment shown in the figure on page 2 is on a City - owned tract. If additional easement width is needed or if other easements are required, Tetra Tech staff can coordinate with City staff and Triad Associates to prepare easement documents. Lan a Architecture arker Landsca Architects will prepare plans and details for landscape elements needed to restore existing f_JQeatures isturbed during construction and to blend the proposed lift station facilities into the neighborhood. JAcoustical Evaluating the noise exposure levels at the residential neighbors is an important part of reducing the impact of this project, given that the proposed location of the new permanent generator will be in close proximity to residential ' City of Renton TETRA TECH, INC. 3 property lines. The Greenbusch Group proposes to make 24 hour measurements to document the existing, pre - construction ambient noise characteristics at the site as a baseline for evaluating the noise impact of the project for the SEPA checklist. Greenbusch will predict noise exposure levels from the operation of the new generator and will compare these levels with Code requirements and also with the existing noise levels at t ite. It is our understanding that the City may wish to pursue meeting the nighttime permissible C.Qdp imits of 45dB Recommendations for silencing of the generator noise will be developed. This typically invo ves ination with design disciplines to specify building elements such as walls, ceilings, doors, louvers and exhaust silencers to provide appropriate levels of sound mitigation. Bid Documents The respective design team members will incorporate interdisciplinary comments, discipline lead comments, quality control and quality assurance review comments, and City comments at each design submittal stage and will prepare bid -ready documents and an opinion of probable construction costs. Permitting and Project Approval Assistance We understand that the bulk of the construction work for this project will occur within improved rights -of -way or exist' ee d that the level of environmental permitting will be minimal. However, we will work with lfson Associ sctively manage this aspect of the project to reduce the project risk associated with environmental permits. We will accomplish this through the following: * Develop a Permit Plan with key milestones and submittal dates that parallel various design stages of the project. * Meet early in the process with the City's project manager and key design team members to identify key technical issues and critical path items. * A critical element to insure timely implementation of this project is to identify and locate wetlands that may occur adjacent to the work area. Direct impacts to wetlands are not anticipated as part of this project, but the early identification of wetlands and other regulated sensitive areas is important for determining specific permit submittal requirements and timetables, particularly if regulated buffers occur within proposed clearing limits. * Once existing sensitive areas are identified and classified per the City's Critical Areas regulations, staff biologist and planners will work with the design team to review anticipated design criteria to avoid as many permit triggers as possible. * Where permit triggers cannot be avoided in a cost effective manner, environmental staff will coordinate with design staff to insure that the specific thresholds and standards required for use of these streamlined approval processes is understood by all designers. * Because no direct wetland or stream impacts are anticipated and the project is not anticipated to utilize any federal funding, we anticipate that the City will be the primary lead for key environmental permits. Once the initial design effort is complete, we will prepare clear, simple, technically complete and accurate SEPA materials and permit materials, where applicable, per the City's standards and code requirements. * Coordinate with City's permit staff following submittal to insure that they have a complete understanding of the project so that they can complete their reviews. Assistance During Bidding The Tetra Tech team will coordinate with City staff during the bidding period to answer bidders' questions. If appropriate, addenda will be prepared to clarify document issues and/or provide a consistent response to all plan holders. TETRA TECH, INC 4 City of Renton Services During Construction Onsite Construction Progress Assistance We understand that City staff will lead construction inspection and administration efforts and wihl call upon tYhe c nQ sultant team -needed basis. OuLprqiqqLmanager will attend the preconstruction meeting. He or a representative of one of the respective disciplines will attend onsite meetings during construction, as appropriate to the stage of construction and the current project issues. Tetra Tech will lead conformance review for structural, mechanical, and electrical construction of the new Lift Station. The majority of this work will not require full-time onsite observation, b it. v ' uire more frequent visits than during the pipeline construction. eosciences will observe soil conditions beneath the foundation�o both the lift station and the electrical / generator building prior to placement of fill materials and/or the base slab. Barker Landscape_ Architects will conduct plan/specification conformance reviews during construction. Engineering Support The team will provide submittal reviews and respond to RFIs. Deferred submittals will be coordinated with the City's building official as required under the building permit. We understand the City will handle telemetry tartup through an existing contract with a control system integrator. \/ Assistance Following Construction The team will provide assistance during startup and testing of mechanical and electrical systems as generally ' coordinated by the City's lead inspector. We will prepare construction record drawings based upon markups provided by the contractor, City staff, and our own staff. We will review O&M Manuals prepared by the contractor based for consistency with the constructed facilities and for conformance with contract requirements. Triad Associates will conduct limited survey after construction to verify sewer inverts and the locations of key 1it station atures. Coordination and Management Tetra Tech will coordinate with the City throughout design and construction. h ve desi nated a project manager who wi v point of contact throughout the pro'eur project manager is responsi a or all aspects of our efforts. We have considered this project carefully and developed a schedule that represents a reasonable timeline for both the alternatives analysis and design phases of the project. Further, it shows a timeline for construction of one possible system configuration. We have also thought out the level of effort required to complete the various portions of the field work, explorations, analyses, design, and construction support necessary to complete this project. The Level of Effort spreadsheet follows the project schedule. i u n Lj TETRA TECH, INC ' City of Renton 5 City of Renton Summerwind / Stonegate Lift Station Consolidation Tetra Tech and Field Avenue Interceptor ID Task Name Duration Start Finish Predecessors Februal March I Aril I May June IJulv I August I Septeml Octobed Novem I Decem I Januaryl Februa I March I Aril I May June I July I August I Septeml Octobe'd Novem 1 Notice to Proceed Coordination and Management Alternatives Analysis Research and Develop Alternatives Meeting w/ City Staff Final Memo and Costs Final Design 30% Design Topo Survey Geotechnical Analysis Initial Layouts Coordination w/ Modeler 30% Submittal w/ Costs 60% Design Pothole and Pickup Survey Easements Permit Drawings 60% Submittal w/ Outline Specs & Costs 95% Design 95 % Submittal w/ PSE & Sched. Preparation of Bid Documents Permitting and Project Approval Sensitive Areas Review and Summary SEPA City Permitting Assistance During Bidding Services During Construction Construction Contract Award Notice to Proceed New Sunset Gravity Sewer New Field Avenue Bypass New Stonegate Lift Station New Gravity Sewer (NE 26th and Lyons) New Force Main Testing and Startup Start new Lift Station and Force Main Side Sewers Connections (NE 26th and Lyons) New Gravity Sewer (NE 24th and Easement) Abandon Stonegate LS Paving Final Connection and Abandon SW LS Final Cleanup and Restoration 1 day 474 days 41 days 25 days 1 day 15 days 120 days 40 days 25 days 25 days 15 days 15 days 10 days 60 days 5 days 50 days 20 days 10 days 20 days 20 days 10 days 191 days 20 days 15 days 90 days 25 days 258 days 231 days 30 days 20 days 10 days 15 days 120 d� av_ s �. 15 days 30 days 15 days 1 day 10 days 15 days 5 days 10 days 10 days 10 days 2/5/07 2/6/07 2/6107 2/6/07 3/13/07 3/14/07 4/4107 4/4/07 4/4/07 4/4/07 4/4/07 4/25/07 5/16/07 5/30/07 5/30/07 5/30/07 5/30/07 8/8/07 8/22/07 8/22/07 9/19/07 2/6/07 2/6/07 5/30/07 6/27/07 10/31/07 12/5/07 12/5/07 12/5/07 1/16/08 2/13/08 2/27/08 2/13/08 3/12/08 3/12/08 7/30/08 8/20/08 8/21/08 9/4/08 8/21/08 9/25/08 9/25/08 10/9/08 2/5/07 11/28/08 1 4/3/07 3/12/07 1 3/13/07 4 4/3/07 5 9/18/07 5/29/07 5/8/07 6 5/8/07 6 4/24/07 6 5/15/07 11 5/29/07 12 8/21/07 6/5/07 13 8/7/07 13 6/26/07 13 8/21/07 15,16 9118/07 9/18/07 18 10/2/07 20 10/30/07 3/5/07 1 6/19/07 13 10/30/07 17 12/4/07 21,25 11/28/08 26 10/22/08 1/15/08 26 2/12/08 29 2/26/08 30 3/18/08 31 7/29/08 30 4/1/08 33SS+20 days 4/22/08 33SS+20 days 8/19/08 33,34,35,31,32 8/20/08 36 9/3/08 37 9/24/08 38 8/27/08 37 10/8/08 31,32,34,35,38,39 10/8/08 39 10/22/08 42 2/5 2 3 3/13 8/20 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33` 34 35 36 37 38 39 40 41 42 43 Page 1 11 11 11 City of Renton LEVEL OF EFFORT STAFF TIME ESTIMATE FOR: SUMMERWIND / STONEGATE LIFT STATION CONSOLIDATION AND FIELD AVENUE INTERCEPTOR Task Description Jeff Lykken PE Principal in Charge Kevin Goss PE PM & Pump Station Lead Barry Scott PE Pump Station QC David Scott PE Pipeline Lead Bryan Kawamura PE Electrical Lead Seth Orgain Architectural Lead Allen Bellew PE QA/QC Lead Civil Engineer CADD / Graphics Clerical Subconsultants HWA Triad Assoc. Adolfson Assoc. Barker Landscape Greenbusch Task 1 Alternatives Analysis Development of Alternatives Planning Level Cost Estimates Hydraulic Evaluation Coordination w/ Hydraulic Modeler Draft and Final Report TASK SUBTOTAL Task 2 Design Topographic Survey Public Involvement Geotechnical Evaluation Acoustical Evaluation & Design Landscape Architecture Cost Estimating Engineering Design 30% Design PS&E 60% Design PS&E 95% Design PS&E TASK SUBTOTAL Task 3 Preparation of Bid Documents Final Drawings & Specs Probable Construction Cost TASK SUBTOTAL Task 4 Permitting and Project Approval Assistance SEPA Support Local Permitting Geotechnical Report Submittal to King County TASK SUBTOTAL Task 5 Assistance During Biddding Pre -bid Site Visit Respond to Bidders Questions Prepare Addenda TASK SUBTOTAL Task 6 Services During Construction On -Site Construction Progress Support Engineering Support Start-up and Operational Assistance Record Drawings O & M Manual TASK SUBTOTAL Task 7 Coordination and Management Project Management TASK SUBTOTAL TOTAL 8 60 4 80 20 20 4 80 80 24 400 80 4 20 24 12 8 2 12 2 24 2 24 2 8 12 4 24 2 32 12 4 4 24 40 18 2 136 8 8 172 24 44 32 8 12 116 16 120 32 24 4 8 32 12 24 4 8 20 32 2 16 4 200 1 8 2 4 12 24 1 8 4 12 24 120 4 20 2 16 16 12 2 36 2 12 12 80 10 100 40 40 4 120 180 241 8 12 80 6 80 80 40 4 120 180 24 20 12 60 24 80 336 40 4 24 4 80 344 60 80 220 24 40 156 24 8 20 8 120 440 60 140 580 80 36 98 40 16 8 40 4 12 8 8 2 16 8 4 4 8 32 2 48 16 6 76 16 32 28 12 68 80 40 2 40 2 24 12 32 2 40 80 16 12 60 40 4 2 4 8 4 2 200 4 4 1 2 24 60 24 40 6 64 8 2 52 12 32 3 44 80 20 4 16 16 16 4 6 2 12 12 12 4 12 6 36 48 0 28 48 28 24 4 24 4 0 90 0 18 12 24 40 4 40 40 12 4 60 8 24 24 4 4 60 8 4 4 16 40 24 40 8 32 24 12 24 60 140 220 8 96 90 164 36 12 198 72 56 80 60 220 0 90 0 0 0 0 0 80 2061 980 481 8581 500 2881 63 8661 9321 33611 4441 4601 2041 204 96 Total Tetra Tech 5077 Total Subconsultants 1408 u B. PROJECT MANAGEMENT Management Approach The key phrase which expresses our project management philosophy is that we strive to "make decisions in the right order." We structure the process of design so that timely decisions are made at the right time in the project. In this way, deadlines are met and wasted effort is avoided. Tetra Tech has a rigorous project management system, and we will use proven management tools to ensure your project meets established schedule milestones and work is performed within the agreed -upon budgets and scope of work. The tools include the following: * A Project Management Plan will be prepared at the start of the project for use by the entire team. The Plan will outline the scope of work; the responsibilities of the staff, the budget for each work element; the staffing requirements for each task; a tasking matrix to track work elements; a decision log to chronicle key decisions made on the project and whether they affect the scope of work, schedule or budget; and the schedule milestones, both internal and external, for the project. The Plan will be web based so that it is easily accessible by team members and can be updated regularly, as required by the Project Manager. * An Internal Startup meeting will be conducted with team members to provide an understanding of the project objectives and to confirm an understanding and buy -in of task assignments and budgets; deliverable and due dates; and the overall project schedule. Contractual requirements, health and safety risks and assumptions used to prepare the scope of work and budget will also be reviewed with the team. * An External Startup meeting will be conducted with the City to confirm the scope of work, schedule and project objectives. Resources and information needed from the City will be confirmed. * Regular Progress Meetings will be held between the Tetra Tech team and City Project Manager. Monthly Progress Reports will be submitted with each invoice. ' * Cost forecasting will be performed on a regular basis to ensure that the costs required to complete the project are in sync with the project budget. * The scope of work, budget and schedule will be monitored for changes from the project baseline throughout the course of the project. Where a change has be identified, the City will be immediately notified, the change will be documented and it's impact will be defined, and the Tetra Tech Project Manager will work with the City to mitigate the change and negotiate an acceptable solution. i� * Quality Control is an integral part of the Tetra Tech approach. Senior staff from the appropriate technical disciplines are assigned at the beginning of the project to work with the technical team throughout the effort, as well as at designated review points. Using these management tools, the entire Tetra Tech team will: * Be continuously aware of the project status * Be able to identify potential problem areas before they significantly affect the project budget or schedule * Be able to shift resources as necessary to respond to issues as they arise * Have the ability to adjust the project schedule to reflect changing priorities * Be able to maintain tight control throughout the project �( * Assure "unpleasant surprises" will not occur. TETRA TECH, INC. 8 City of Renton Quality Assurance Procedures Quality Control is an integral part of the Tetra Tech approach. Each discipline has a senior staff member designated to oversee the design staff and conduct a discipline -specific QC check prior to each submittal. Tetra Tech has asked that each subconsultant use this same structure by designating a specific QC r-resentative fl their_scinlme Overall QA checking will be complete �%bYAllen Be ew, who administers the company's Quality Assurance program. Team Organization ±!^ City of Renton Dave Christensen 8, Assigned Project Manager Principal -In -Charge Quality Assurance Jeff Lykken, PE (1) Allen Bellew, PE (1) Quality Control Pjanager Discipline Leads (1-6) kKeroneft!s,PE(1) Project Engineer/Pipeline Design ,,........ David Scott, PE (1) Pump Station Design.... ................... Kevin Goss, PE (1) Electrical/Controls Design__ ....Bryan Kawamura, PE (1) Architectural Design _... ...... . _ _ ...Seth Orgain (1) Survey Manager ..................... Brad Freeman, PLS (6) I La John Barker, RLA 3 Geotechnical Design................Steve Greene, RG (5) Acoustical Design ........................... Adam Jenkins (4) EnvironmentaUPermttting....._ .. __Bens Burke (2) Legend t l Tetra Tech - 2) AdoMson - 3) Barker Landscape - 4) Greenbusch - 6) HWA - 6) Triad Availability of Key Staff CAPACITY of Kev Personnel for Assignments between Jan 2007 and Dec 2007 Availability by Quarter % of Billable Hours Q1 Q2 Q3 Q4 Key Personnel '07 '07 '07 '07 Current Project Commitments/Date Concluded Kevin Goss 30 40 50 50 KC -Kirkland Pump Station (12/09); Mercer Island Pump Station (3/07); SCWSD-Lake Desire Water&Sewer (12/07); Kirkland — NE 80th Water&Sewer (12/07) JeffLykken 20 40 40 40 Blaine Storage (01/07); Mercer Island Lake Line (03/07); King County CSO (12/08) David Scott 25 25 35 35 Kirkland NE 80th St Sewer & Water (3/07), SPU CSO Retrofit (3/07), AWWD Sewer Comp Plan Modeling (6/07), SPU CSO Plan (12/08), Kirkland Pump Station (12/09) Bryan 50 75 80 80 SPU Reservoir Burying Program (2009) Kawamura Baker River Fish Trap (2008) Steve Greene 25 25 25 25 Deception Pass State Park (12/2006); SR 518 (01 /07) HWA Benn Burke 20 10 30 30 Coal Creek Bank Stabilization (12/0 7 ); Log Boom Park Adolfson Feasibility Study (4/07); Brightwater Regional Reclaimed Water (8/07); Brightwater Conveyance Permitting (12/07), Tacoma Water Wetland Monitoring (12/11) City of Renton TETRA TECH, INC 9 I C. PROJECT TEAM MEMBERS 1 I I Firm Profile Established in Seattle in 1943, Tetra Tech (Tetra Tech) is a consulting firm of engineers, architects, and planners. We have a strong multidiscipline team of professionals ready to serve the City of Renton. These include sanitary, civil, structural, electrical and mechanical engineers; hydrologists and GIS specialists. Among our overall staff of 111 there are 34 civil engineers, 14 electrical and control systems engineers, 7 architects, 5 structural engineers, 6 mechanical engineers, 6 GIS specialists, and 4 hydrologists. The majority (72) work out of the Seattle office, with additional offices in Bothell, Stanwood, Portland, Spokane, and Juneau, Alaska. A major component of our professional practice has included design and construction of numerous treatment, sewerage and pumping systems for clients throughout the Pacific Northwest. In addition to new system designs for sewer and water, we are experienced in rehabilitation and upgrade work. We will manage and execute this work from our Seattle and Bothell offices. Qualifications and Roles Pump Station (TT ): Kevin Goss, PE —Project Manager/ Design; Barry Scott, PE—QA Kevin Goss has over ten years of experience in civil engineering and has managed projects ranging from thousands of dollars up to approximately $9M. His design experience includes extensive collection and distribution piping design and both design and management of water and wastewater pumping projects. He has served as a construction observer for both pump station and pipeline projects. While with his previous employer he managed the predesign study of sewer replacements for several mini -basins in the Renton Highlands area (Sunset Sewer Interceptor, Phase 3). He is currently Project Manager for reconstruction of King County's Kirkland pump station and force main, an 8-mgd facility in downtown Kirkland. For the City of Mercer Island, he is designing a submersible sewage pump station in conjunction with a sewer line beneath Lake Washington. Barry Scott, Vice President, has designed pumping systems ranging in size from very small flows to those in excess of 2,000 cfs. His experience includes predesign, design, and value engineering review of pump stations, storage reservoirs, and pressure and level control systems. Working with our quality assurance staff, Barry developed design criteria for Tetra Tech's wastewater pump station work and has been involved with every major lift station design prepared by the Seattle office in the last 30 years. Jeff Lykken, PE (TT) — Principal in Charge Manager of the Water Resources Group, Jeff has over 18 years of professional experience managing a wide variety of projects. Jeff was Lead Engineer on King County's recently completed In pilot projects, North Creek Storage Facility and the Swamp Creek Trunk Sewer Extension and is currently managing Mercer Island's Sewer Lake Line and Pump Station No. 4 replacement. Jeff has provided extensive design and construction services within the City of Renton, as project manager and engineer of the Kennydale lakeline replacement, construction engineer for King County's Eastside Interceptor, and design of numerous drainage and paving projects for the Boeing Company. Pipeline (TT): David Scott, PE —Design; Doug Genzlinger, PE---QA David Scott has 12 years of civil engineering experience focused on detailed design and planning for force mains, pump station layouts, marine outfalls, gravity sewers, storm sewers and watermains. He is currently project coordinator for expansion of King County's Kirkland Pump Station and the design engineer for the associated force main and influent sewer work. He is also project engineer for the upgrade of the NE 80th Street sewer and watermain for the City of Kirkland. David was a team member for the detailed design of 16,000 linear feet of twin 24-inch HDPE force main for the City of Marysville; and design of 6,000 linear feet of gravity sewer for the South Snoqualmie Hills Sewer Project in Snoqualmie. He has expertise in sewer modeling and planning, currently supervising the modeling team for the capacity analysis associated with the Alderwood Water and Wastewater District Sewer Comprehensive Plan and the City of Seattle CSO Plan Update. Doug Genzlinger is a senior civil engineer with 30 years experience in design and construction management. He has been District Engineer for several local sewer and water districts, overseeing all engineering aspects for each TETRA TECH, INC. 10 City of Renton district. Many projects in which he is involved are unique pipeline and tunnel projects, including restoration of , existing pipeline systems using trenchless technology. Doug was Project Manager for the City of Fife's five wastewater pump stations, 3 miles of forcemain and 2.5 miles of gravity interceptor. ' Electrical/Controls (TT): Bryan Kawamura, PE —Design; David Bloxom, PE—QA Bryan Kawamura has 8 years experience in electrical and control system design and implementation. This includes design development of the electrical and control system for the Mercer Island Lake Line. His responsibilities have included: field investigation; control system panel layout; control 1/0 wiring development; system testing; startup; and as -built drawing development. Bryan works with projects focusing on PLC, and SCADA software development and trouble shooting. David Bloxom oversees all electrical projects at Tetra Tech, with a primary focus on technical direction. His project experience ranges from small facility studies to full-scale design and implementation projects. He has also been responsible for designing, testing, and supervising the installation and start up of electrical, instrumentation, telemetry, control and data management information systems. Most of these projects were for water and wastewater treatment facilities. Architecture (TT): Seth Orgain—Design; Tom Roth, RA—QA Seth Orgain has been practicing architecture for over 5 years and has gained experience in architectural design, documentation, permitting, and construction management while working on a broad range of project types. He is currently preparing architectural drawings for the Mercer Island Pump Station #4. Tom Roth has a long history of working with public agencies. His client experience includes design work for a variety of local organizations such as the City of Mercer Island, Issaquah Public Works Department, King County Parks and Recreation, Pike Place Market PDA, Covington Water District and the City of Seattle. He is currently managing Tetra Tech's architectural design of the Pump Station No. 4 Control Building on our Mercer Island project. Relevant Projects LID 98-2 Sewer Extension City of Fife, Washington Tetra Tech completed design of five wastewater pump stations, approximately three miles of force main and nearly 2.5 miles of gravity interceptor for the City of Fife. Flow is pumped to the Tacoma Wastewater Treatment Facility. The initial task was to determine the most economical and feasible alternative to sewer almost two- thirds of Fife. Alternatives considered a variety of force main alignments with pump station scenarios. Design and construction was completed in four contract phases: #1 — force mains; #2 — pump stations; #3 — the CMC Heartland and South Oxbow gravity sewers; and #4 — 70th Avenue E gravity sewer. For ease of maintenance, all pump stations are submersible, installed in either a 10-foot diameter manhole or large cast -in -place structure, depending on pumping requirements. Pump station challenges included selection of common pump sizes to accept a wide range of flows. The $11 million project was constructed as an LID, with the first construction contract beginning in the summer of 2000 and the last contract completed in April 2003. Completion of the project lifted a 4-year building moratorium. Challenges included construction of large diameter HDPE pipe in a heavily traveled roadway with a substantial number of utilities. Contract 3 constructed deep sewers in soft soil conditions using precast concrete slabs to stabilize the trench bottom. Tetra Tech services provided: Project management; civil, structural, hydraulic, mechanical design of pipeline and pump stations; construction management assistance; permitting acquisition. Proposed staff involvement (including subconsultants): Barry Scott, Principal -in -Charge & Mechanical Engineer; Doug Genzlinger, Project Manager; Allen Bellew, QA Manager; Dave Bloxom, Electrical QA; Bryan Kawamura, Electrical Engineer City of Renton TETRA TECH, INC. 11 Sewer Lake Line and PumpStation No. 4 Replacement current p (current) City of Mercer Island, Washington Tetra Tech is responsible for the preliminary design development, permitting and final design documents to replace approximately 9,000 feet of sewer line located in Lake Washington and relocation of an existing sewer pump station. The initial project phase included the development and analysis of alternatives to rehabilitate or reconstruct ' the line in the lake, or relocate the line along a new upland alignment. Preparation of the environmental documentation and permit applications for implementation were prepared following the decision to build a new line in the lake. Permitting and environmental requirements included preparation of an EIS, Corps of Engineers 404(b)1 analysis, a shoreline characterization, JARPA permit, biological assessment, and a mitigation plan. The pump station will be cast -in -place with submersible pumps. A small building will house electrical and control equipment as well as a standby generator. Tetra Tech is currently preparing plans, specifications and cost estimates for construction of the improvements. Construction is estimated to begin in mid-2007 and projected to cost approximately $12 million. ' Tetra Tech services provided: Project management; civil, structural, hydraulic, mechanical, electrical design of pipeline and pump stations; construction management assistance; permitting acquisition. Proposed staff involvement (including subconsultants): Jeff Lykken, Project Manager; Kevin Goss, Pump Station Design; Tom Roth, architecture lead; Seth Orgain, architect; Barry Scott, Pump Station QA; Dave Bloxom, Electrical QA; Bryan Kawamura, Electrical and Controls Design; Lorne Balanko of HWA, geotechnical; John ' Barker, Landscape Architect; Julie Wiebusch, Acoustical Consultant. Soos Creek Area Pump Station D and Pipeline Predesign (2004) King County DNRP Wastewater Division, Washington Tetra Tech led a multidisciplinary team for the planning of a 26 mgd wastewater pump station and 22,000 feet of force main through high traffic area of Covington, wetlands, and other sensitive areas. Preliminary design concluded that the facility should be designed to handle a wide range of flows, from 5 mgd to 26 mgd. Under consideration were the number of force mains and operation required to minimize solids deposition, corrosion and odor generation. The pump station was to be designed for the ultimate 26 mgd flow, but in the early years to have pump and support equipment to pump around 10 mgd. Inline storage was proposed to shave peaks, reduce station capacity, ' and improve system performance at lower flows. Both single and two -stage pumping were evaluated. The facility was to include standby power, odor control equipment, and chemical injection for corrosion control and downstream odor control. The project looked at a number of routes for the proposed twin force main system, requiring a thorough review and analysis of the permits, easements and associated costs for each alignment. A number of meetings were held with the public and affected jurisdictions to inform them of the project and to receive input to the various pipeline ' alignments. Following submittal of the preliminary design report (which was prepared on time and within budget), the project was put on hold without resolving the pipeline routing issue, pending funding and further collection of flow data. ' Tetra Tech services provided: Project management; civil, structural, hydraulic, mechanical design of pipeline and pump stations; public involvement, permitting, easement, and right-of-way acquisition. Proposed staff involvement (including subconsultants): Barry Scott, Principal in Charge; Doug Genzlinger, Project Manager; Kevin Goss, pump station design and system hydraulics; Dave Bloxom, electrical QA; Lisa Adolfson, environmental analysis; Julie Wiebusch, Greenbusch, acoustical consultant. Kennydale Lakefront Sewer Replacement (2002) City of Renton, Washington The Kennydale lakefront sewer line was installed in 1972 to serve approximately 52 waterfront homes. It is located approximately 40 feet from the shoreline, often under boat docks, and is partially buried for 4,700 feet from a fresh water flush station to a sewage lift station. The 8-inch diameter ductile iron pipe has been difficult to clean and maintain for many years due to numerous sags, bends and limited access points. Tetra Tech performed a predesign TETRA TECH. INC. ' 12 City of Renton analysis of alternatives and completed construction documents for three precast concrete manholes to be placed at existing low points. Predesign consisted of a review and evaluation of alternatives for rehabilitating or replacing the facility. Alternative identification and evaluation was performed using a workshop approach in which key stakeholders were assembled to ensure that all project goals and constraints were identified before moving ahead in the evaluation effort. Workshop participants included City of Renton engineering, operations and maintenance staff; a marine contractor to address constructability issues; the Department of Fish and Wildlife Area Habitat Biologist to identify regulatory constraints; and key design team members to address construction, permitting and community involvement issues. Because the cost of replacement alternatives was so great, and the remaining service life of the lake line uncertain, the recommendation was to implement interim measures to better maintain the line and assess its condition. All construction was completed "wet" using divers to cut the existing pipeline and to assist placement of manholes using a barge -mounted crane. Access to each manhole required a custom -fit portable access shaft for dewatering and cleaning. Tetra Tech services provided: Predesign analysis; construction documents; construction observation. Prepared an Environmental Checklist and Biological Assessment and obtained HPA, Corps Nationwide, and Shoreline Substantial Development permits. Proposed staff involvement (including subconsultants): Jeff Lykken, Project Manager; Benn Burke, Adolfson, environmental documentation. Subconsultants Geotechnical (HWA): Steven Greene, LG, LEG— lead investigator; Lorne Balanko, PE—QA Steven Greene has a masters degree in geology and 25 years of experience as an economic geologist/engineering geologist. Water, wastewater, and stormwater projects have formed a major part of his consulting endeavors. He has conducted geologic investigations and evaluations for projects including plants, pump stations, pipelines, urban infrastructure, and landslides. Steve worked with Kevin Goss as lead of the geotechnical evaluation for Phase 3 of the Sunset Interceptor for Renton. Recently, he worked with Tetra Tech on Kirkland's NE SOth Street Sewer Replacement (with Kevin Goss) and the Winslow Wastewater Treatment Plant. Lorne Balanko has 40 years experience encompassing a broad variety of geotechnical engineering. Projects involving sewer and water systems have formed a major part of Mr. Balanko's work experience and range from distribution and collection pipelines and pumping stations for municipal water and sewer works to major treatment plant facilities and facilities upgrades. He provided senior review and/or project management for NE Sunset Boulevard Improvements with Kevin Goss and the City of Renton and for the Mercer Island Lake Line with Jeff Lykken and Kevin Goss. Acoustical (Greenbusch): Adam Jenkins —Design; Julie Wiebusch, INCE—QA Adam Jenkins received his bachelor degrees in Electrical Engineering and Physics in 2004 from Seattle Pacific University, where he placed an emphasis on researching acoustical phenomenon. Since joining Greenbusch as an acoustician, Adam has participated in numerous wastewater projects, including the Mercer Island Pump Station #4 and Bainbridge Island Wastewater Treatment Plant with Tetra Tech; Klineline Pump Station; Blaine Water Reclamation Facility; and Columbia Boulevard Digester Expansion (Oregon). Julie Wiebusch has specialized in the field of acoustics since 1974 and is a respected leader of acoustics in the Pacific Northwest. Julie's extensive experience in design, as well as her ease with translating complex ideas into tangible designs, have been instrumental in the successful completion of numerous projects. Her wastewater experience includes over 30 pump station and treatment plant acoustical designs and upgrades. Julie regularly performs forensic studies to identify the source of noise or vibration and development of appropriate mitigation; authors reports and technical memos, including the noise sections of EIS and specifications; and represents the City of Renton TETRA TECH, INC 13 tdesign team at Community meetings, presenting environmental noise studies to non -technical audiences. Julie has teamed with Kevin Goss and Tetra Tech on Soos Creek PS D, Kirkland PS, and Mercer Island PS #4. ' Environmental/Permitting (Adolfson): Benn Burke —Analysis; Lisa Adolfson — QA Berm Burke is a Senior Fisheries Biologist with more than 14 years of experience who has prepared biological assessments, salmonid stream analysis, wildlife inventories, and mitigation planning and designs for wetlands and streams to support a wide range of public and private sector projects. He has assisted numerous clients with Endangered Species Act compliance and successfully obtained numerous State, Federal, and local permits. He has teamed with Tetra Tech on the City of Renton's Kennydale Lake Line Sewer Replacement (for which he provided permitting support) and King County's Swamp Creek Interceptor (Biological Assessment and environmental monitoring during construction) . His work in Renton includes stream restoration design of Honey Creek. Lisa Adolfson has extensive experience preparing environmental documents including SEPA/NEPA impact ' statements checklists and assessments, as well as environmental permit applications, for wastewater treatment and distribution projects. She has over 18 years experience developing and implementing surface water, ground water and stormwater monitoring projects. She has frequently teamed with Tetra Tech and served as the environmental ' task lead for King County's Soos Creek Pump Station D and Pipeline predesign project. She provided EIS analysis for Tetra Tech's design of the seven -mile pipeline corridor along Swamp Creek in Snohomish County, which abutted large areas of wetlands. ' Landscape (Barker Landscape Architects ): John Forrest Barker —Design / QA; Amber Hadenfeldt—Design Founder and Principal of the firm, John Forrest Barker is a registered Landscape Architect in Washington State and holds a Masters degree in Landscape Architecture from the University of Washington. John has over 25 years experience in public landscape architecture and site development, and has received dozens of awards for public park and playground projects throughout Washington State. John's primary objective is to create places that are treasured ' by the community. He is currently working with Tetra Tech on Mercer Island's Pump Station #4. Amber Hadenfeldt will assist John Barker in the public design process and all aspects of the project. Amber holds a Bachelor's Degree in Landscape Architecture from the University of Washington. She assists with project management, design, and drafting on a variety of projects. Amber is a very proficient garden designer with an excellent knowledge of native and ornamental plants. Brad Freeman, Triad Associates — Survey Project Manager Brad Freeman has over 30 years of surveying experience in the Pacific Northwest, with expertise in boundary, topographic, GPS, utility route mapping and ALTA/ACSM Land Title surveying. His experience includes the City of Renton's Downtown and Edmonds Avenue Sewer Extension Projects. In addition to work with the City of Renton on many types of projects, his firm has recently designed a substantial amount of roadway and utility infrastructure within the City for private land developers. TETRA TECH, INC. 14 City of Renton D. REFERENCES We take great pride in the work we do and the satisfaction of our clients. We hope our references will confirm our dedication to those goals. Tetra Tech Steve Banham Russ Blount, PE Erika Herrin Director of Public Works Director of Public Works Water Quality Planner II City of Blaine City of Fife King County DNRP/WTD (360)332-8820 (253)922-9315 206-684-1138 sbanham@cityofblaine.com rblount@cityoffife.org Erica.Herrin@metrokc.gov Project Manager Dave Snider Dave Dittmar Anne Tonella-Howe Senior Project Engineer Capital Project Manager IV Assistant City Engineer City of Kirkland King County DNRP/WTD City of Mercer Island 425-587-3832 206-684-1813 206-236-7687 dsnider@ci.kirkland.wa.us david.dittmar@metrokc.gov anne.tonella-howe@ci.mercer- island.wa.us E. INSURANCE TUCKM can meet the City's requirement for $1,000,000 of Professional Liability Insurance. City of Renton TETRA TECH, INC. 15 ' TETRA TECH, INC. KEVIN GOSS, P.E. Title: Senior Civil Engineer Kevin has over ten years of experience in civil engineering. As a Project project Role: Manager, he provides utility design and coordination, planning, cost projections, ' and construction contract administration services for sewer and water systems. As Project Manager a Design Engineer, he leads pumping station and pipeline projects for both water Education: and sewer system. BS, Civil Engineering, ' EXPERIENCE University of Washington, 1998 Sunset Sewer Interceptor, Phase 3, City of Renton, 2004 Registration/Certification: Kevin was the project manager for the predesign study of upgrades to the current professional Engineer: WA, Sunset Interceptor east of Union Avenue. The study ultimately recommended 2001 diverting pumped Summerwind and Stonegate flows to Field Avenue to preserve capacity of the system on Duvall Avenue. Office: Juanita Lift Station Elimination and Emergency Response Connection, City Seattle, Washington of Kirkland, 2003 Years of Experience: Kevin was lead designer for this gravity sewer project. The City initially 10 ' undertook a siting study for relocating the lift station out of a wetland. Early in design, Kevin devised a solution wherein 2,300 linear feet of 18-inch gravity Years with Tetra Tech: interceptor sewer, at depths up to 20 feet, could drain the basin instead. The 2 gravity sewer, with several hundred linear feet constructed on steel piles for structural support, extends under a salmon -bearing stream and across a wetland. Key Areas of Experience: Portions of the lift station yard area were restored to wetland conditions to offset ■ First hand experience with limited wetland impacts elsewhere. Permits were secured on the local, state and sewer planning for federal levels. Kevin helped to coordinate provided survey, design, permitting Summerwind/Stonegate including two Corps of Engineers nationwide permits, coordination with wetlands area of Renton biologist, geotechnical and structural engineering subconsultants, preparation of contract documents, and engineering support during construction. ■ Project Management and Construction ' Sewer Lakeline Replacement, City of Mercer Island, current Administration Kevin is the lead engineer coordinating the efforts of the design team for the pump station and is conducting the hydraulic and mechanical design. The facility a Sewage Collection, consists of. a cast -in -place wet well with submersible pumps; vaults for valving, Pumping System, and flow metering, and ventilation (including provisions for future odor control); and Force Main Systems a detached control building housing electrical/control systems, a standby a Water Distribution Piping, generator set, fuel storage, and an wash water system. He is working with many pump Station, of the same team members proposed for the Summerwind/Stonegate project, Flow/Pressure Control, and including the principal in charge, architects, landscape architects, and acoustical Intertie Systems consultant. The project is expect to advertise in February 2007 and be in construction for two years. Total Project Cost: $15M. I K. Goss, Page TETRA TECH, INC. King County WTD Pump Station, Kirkland, WA, current Kevin is the project manager and lead engineer for wet well, raw sewage pumps, and process piping for the County's upgrade of this pump station. The design process is evaluating impacts to existing system operations (hydraulic transients, force main operating parameters) resulting from changes to pump units. The in -station process piping and pump foundations are being modified and a flow meter will be added. The project involves extensive coordination with County engineers and operations and maintenance staff and the development of solutions to address input from varied perspectives. Total Project Cost: $6M. King County WD #90 Steel Water Main Replacements (May Valley Road / SR900), 2002/2003 Kevin was the lead engineer and primary client representative for King County Water District No. 90's PWTF-funded replacement of two plus miles of aging steel water mains on May Valley Road east of SR900 and on SR900 east of 148th Ave SE. Kevin developed the scope, schedule, budget and amendments thereto. He managed the entire project team and coordinated all deliverables for both projects. Kevin conducted contruction administration services and served as the primary client contact with the Owner for this project. He reviewed all invoicing to the owner and met monthly with the elected board and staff. Total Project Cost: $1.4M. King County WTD Soos Creek Area Pump Station D, Southeast King County, Washington, 2005 Kevin was the lead pump station designer for the predesign phase of this project. The 26 mgd station would pump 26 mgd through over four and a half miles of 10- and 30-inch force mains at approximately 230 feet of head. Kevin was responsible for coordinating Tt/KCM and subconsultant staff for the pump station design portion of the project, including project deliverables. The project considered an online influent storage system, the wet well, two sets of raw sewage pumps (four total), and station process piping. He also coordinated the site civil and ancillary mechanical systems design. He worked extensively with County planning staff to determine not only relevant peak flows, but also diurnal and seasonal flow variations that set important boundary conditions on the design of this facility. Total Project Cost: $29M, approximately $10.5M for pump station Soos Creek W&S District Lift Station 10B, Southeast King County, 2004 Kevin was Assistant Project Manager for the replacement of Soos Creek WSD's LS l0A with a new 14.4 MGD sewage pump station. The project involved the development of a preliminary engineering report presenting alternatives and recommending a project approach. It also involved the evaluation of the existing 30+ year old lift station for the possibility of upgrading it and incorporating it into the system operation. He worked closely with the team to develop the initial project scope, schedule, and budget and amendments thereto. Kevin managed the seven subconsultants from scope development to invoicing. He developed and managed the overall project schedule and the weekly tasking of the prime consultant's and all subconsultant teams. Kevin also coordinated all engineering support to the project permitting team and represented the District in meetings with permitting agencies. Total Project Cost: $9M. K. Goss, Page I N TETRA TECH, INC. JEFFREY W. LYKKEN, P.E. Manager of the Water Resources Group, Jeff has over 18 years of professional experience managing a wide variety of projects. His expertise includes utilities design for sanitary and storm sewers, CSOs, and water transmission mains. Many of his projects include the design of large diameter pipelines for sewage and stormwater conveyance. He has been involved in the design of numerous trunk pipeline projects ranging in size from 36-inch to 84-inch diameter, often involving installation using trenchless technology techniques. He has participated in all phases of the project development process, from planning, alternatives analysis and predesign; through permitting, final design and construction. His experience includes hands-on design and construction services within the City of Renton, as project manager and engineer of the Kennydale lakeline replacement, King County's Eastside Interceptor, and numerous drainage and paving projects for the Boeing Company. EXPERIENCE Sewer Lake Line Replacement, City of Mercer Island, WA, current Project Manager for the preliminary design development, permitting and final design documents to replace approximately 9,000 feet of sewer line located in Lake Washington and relocation of an existing sewer pump station. The initial project phase included the development and analysis of alternatives to rehabilitate or reconstruct the line in the lake, or relocate the line along a new upland alignment. Preparation of the environmental documentation and permit applications for implementation were prepared following the decision to build a new line in the lake. Permitting and environmental requirements included preparation of an EIS, Corps of Engineers 404(b)l analysis, a shoreline characterization, JARPA permit, biological assessment, and a mitigation plan. Tt/KCM is currently preparing plans, specifications and cost estimates for construction of the improvements. Construction is estimated to begin in 2007 and projected to cost approximately $12 million. Kennydale Lakeline Replacement, City of Renton, WA, 2001 ' Project Manager for the rehabilitation design of a flush station sewer system and 8-inch diameter sanitary sewer located in Lake Washington. The project began with a predesign study to investigate replacement and rehabilitation alternatives for the system. The preferred alternative was to rebuild the existing flush station and rehabilitate the existing sewer line. Design included preparation of PS&E and regulatory documentation to meet ESA requirements, application for permits and regulatory approvals required for construction, and providing administration and community involvement support to the City during construction. Title: Principal/Senior Project Manager Project Role: Principal in Charge Education: B.S., Civil Engineering, University of Washington, 1987 Registration/Certification: Civil Engineer, WA, 1992 Office: Seattle, Washington Years of Experience: 19 Years with Tetra Tech: 16 Key Areas of Experience: ■ Project Management ■ Pipeline Design ■ Drainage System Design ■ Water and Wastewater Analysis & Design ■ Hydrologic and Hydraulic Analysis ■ Oil -Water Separator Design ■ Cost Estimating ■ Permit Application and Coordination ■ Construction Management J. Lykken, Page 1 TETRA TECH, INC. ' King County Eastside Interceptor Section 1 Capacity Upgrade, Renton, Washington, 2002 ' Project Manager for the construction support for the restoration of capacity to the 108" diameter Eastside Interceptor in Renton, WA. This interceptor was damaged in a magnitude 6.4 earthquake in 1965. The repairs undertaken at that time , reduced the capacity of the interceptor by about 20%. This project restored the lost capacity by construction of a 72" diameter tunnel to bypass most of the affected portion of the pipeline. The tunnel invert is about 30 feet below grade, 20 feet below ground water, and in loose soils. Construction cost was approximately $5.4 million. , King County Swamp Creek Trunk Sewer Extension, Kenmore, WA, 2002 Project engineer for the development of plans, specifications and cost estimates for 4,300 feet of 36-inch to 72-inch diameter King County trunk sewer. The trunk sewer was constructed using both open cut and tunneling methods. Two sections of the trunk sewer totaling approximately 1,100 lineal feet were constructed using tunneling methods: One 48- inch tunnel is beneath the existing Swamp Creek Bridge at NE 92nd Street and installed between existing bridge piles spaced at approximately 6 feet on center. A second section of the trunk sewer is a 72-inch diameter line to be installed using a Lovat TBM. The project includes installation of approximately 1,500 feet of 8-inch diameter collector sewer for the Northshore Utility District along the same alignment as the trunk sewer. Final design included preparation of a Risk Analysis that addressed anticipated risks for tunneling, access shaft construction, dewatering, and open cut construction. The Risk Analysis was developed in conjunction with County staff and documents the decisions and action taken for each risk identified. Construction cost was approximately $5.9 million. King County North Creek Storage Facility, Bothell, Washington, 2003 Project Engineer, assisted in the preparation of plans, specifications and cost estimates for a 6-million gallon underground equalization storage basin for raw sewage that was constructed adjacent to the North Creek Pump Station in Bothell, WA. The facility includes control gates for filling and emptying storage chambers within the facility, odor control, and flushing (cleaning) devices. Design was performed on a fast -track schedule, allowing only 9 months for predesign and design. King County Regional Infiltration/Inflow Control Program, 2005 South County Local Area Manager for the 5-year regional I/1 study in which thirty-four special purpose districts and municipalities joined together with King County to reduce III in accordance with the Regional Wastewater Service Plan. Responsibilities included daily communications, coordination and project oversight for the entire south county area, and leading the effort to develop sewer standards for I/1 control to be used by each of the 34 agencies discharging to the King County system. Lead design engineer for the development of plans, specifications and cost estimates for 10 pilot projects that totaled approximately $8 million in construction cost. Central Storm Drainage Improvements, City of Auburn, WA, 2000 Project Manager for the preliminary design development and final design documents for storm drainage upgrades in Auburn's 444-acre Subbasin E. Storm drainage upgrades included replacement of nearly two miles of 18- to 60-inch diameter pipeline. The improvements were constructed under three separate construction contracts over a four-year period. The construction included a tunneled 48-inch diameter crossing of the Burlington Northern Railroad using an Akkerman TBM. J. Lykken, Page 2 Fj NTETRA TECH, INC. DAVID SCOTT, P.E. David has 10 years of civil engineering experience focused on sewer and culvert network rehabilitation in both Washington and the United Kingdom. He has undertaken detailed design for force mains, pump station layouts, marine outfalls, gravity sewers, and storm sewers. His infrastructure capabilities include network planning for combined and separate sewer networks, sewer network computer modeling, and structural/hydraulic assessment of existing pipe networks. He is currently lead engineer for expansion of the City of Kirkland's Pump Station force main and influent sewer work. For the Mill Creek Sanitary Sewer Project in Stayton, OR, he undertook surge analysis for a proposed 4 mgd sewage pump station and 8,600-1f force main, which included investigation of pump trip conditions and recommendation of surge mitigation measures. David was a team member for King County's Soos Creek Pump Station No. D; preliminary pipeline alternatives analysis for the Mercer Island lake line rehabilitation; 16,000 linear feet of twin 24-inch HDPE force main for the City of Marysville; and 6,000 linear feet of gravity sewer for the South Snoqualmie Hills Sewer Project in Snoqulamie. EXPERIENCE Soos Creek Pump Station Predesign, King County, Washington Design team member for predesign of 21 mgd sewage pump station. Responsible for coordinating site development, force main material selection and surge analysis and preparation of associated report chapters. Title: Civil Engineer Project Role: Project Engineer Education: Queen's University of Belfast/M[Eng Civil Engineering, (with Distinction) 1994 Registration/Certification: Civil Engineer: WA, 2003 Office: Seattle, Washington Years of Experience: 10 Years with Tetra Tech: 2 Key Areas of Experience: ■ Sewer Network and Culvert Hydraulic Analysis Mill Creek Sanitary Sewer Project Surge Analysis, Stayton, Oregon Undertook surge analysis for proposed 4 mgd sewage pump station and 8,600 • I&I Investigation linear feet force main, including investigation of pump trip conditions and m Wastewater Collection and recommendation of surge mitigation measures. Conveyance Design South Snoqualmie Hills Sewer Project, Snoqulamie, Washington ■ Marine Outfall Design Design team member responsible for specifications and cost estimation for sewer extension and rehabilitation project. Scheme included 6,000 linear feet of gravity sewer, with pipe diameters ranging from 8 to 18 inch, and replacement of approximately 500 linear feet of water main. Effluent Transfer Pipeline, Marysville, Washington Team member for design of 16,000 linear feet of twin 24 inch HDPE force main responsible for the vertical profile, design of piping appurtenances, and preparation of specifications. D. Scott, Page 1 TETRA TECH, INC. ' 1 Lake Line Rehabilitation, Mercer Island, Washington Assisted in development of preliminary pipeline alternatives for rehabilitation of gravity sewer and force main ' conveyance of lake front properties adjacent to Lake Washington. Brightwater Influent Pump Station, King County, Washington Design team member for predesign of 150 mgd Influent Pump Station. Responsible for coordination and compilation of ' the Conditional Use Permit drawing set. In addition, examined potential reuse water applications, considering cross connection control and other feasibility issues, and prepared associated technical memorandum. Also, coordinated with design to technical to ' other engineers prepare a memorandum related standby power supply options. Ross Avenue Water Main Extension, Everett, Washington Design team member for 7,800 linear feet HDPE water main extension responsible for modification of existing standard details for application with PE, recommendation of pipe coating technologies for ductile iron fittings in corrosive soil conditions, and preparation of specifications. WWTW Upgrading Scheme, Stevens Pass Sewer District, Washington Responsible for design of nonpotable water distribution system and scum suppression system for treatment works serving the ski resort and surrounding residential properties. Cal Anderson Park Phase 4, Seattle, Washington Team member providing subconsulting services for design select elements of the final phase improvements at Cal Anderson Park (Lincoln Reservoir). Responsible for review and design of drainage at park entrances and children's play area. Helen's Bay Sewer Rehabilitation, Water Service (NI) Project Manager for sewer rehabilitation of suburban combined sewer network adjacent to recreational beaches. Responsible for the coordination of the multi -disciplinary design team, coordination with goverriment and private stakeholders, authoring/compiling electronic contract documentation and providing bid assistance. Project included 31,000 linear feet of reinforced concrete sewer; 6,500 linear feet of PE force main; 3,000 linear feet of PE water main; rehabilitation of one existing pump station; and design of three new pump stations with 12,500, 140,000, and 240,000 gallon storm storage tanks. Kilkeel Habor Sewer Rehabilitation, Water Service (NI) Senior Design Engineer/Project Manager for 3,000 linear feet of force main installation, sewer system extension, and water main upgrade through Harbor estate. The project included application of no-dig/lining technique for river crossing and liaison with local industry and harbor representatives for permitting and community relations. North Antrim Marine Outfalls, Water Service (NI) Design Engineer for four PE marine outfalls ranging from 500 to 3,300 linear feet in length with diameters between 10 and 20 inches. Undertook diffuser port flow balancing analyses and buoyancy collar design. Produced associated buoy maintenance contract and supervised bid process. D. Scott, Page 2 1 TETRA TECH, INC. ALLEN C. BELLEW, P.E. Title: Associate/Quality Assurance Allen Bellew has over 32 years professional experience in mechanical Manager engineering. He has extensive engineering experience in pump and piping Project Role: systems, design of maintenance shops, and office buildings for water resource Quality Assurance related projects such as wastewater, and water and storm water treatment facilities. He also has experience in HVAC design, including heat loss/gain Education: tcalculations, duct sizing, heat pump units, hot water boiler installations, University of Washington, B.S. ventilation equipment and heat recovery systems and controls. Allen has Mechanical Engineering, 1973 participated in value engineering and predesign studies as well as design of school and hospital facility HVAC, plumbing and fire protection systems. His areas of Registration/Certification: expertise are supplemented by a thorough background in writing specifications, Mechanical Engineer: ' preparing cost estimates, reviewing contractor's equipment submittals and WA, 1978; HI, 1984; CO, providing onsite construction observation. 1988; AK, 1989 As quality assurance manager, Allen is involved in all phases of projects as an Office: ' independent reviewer. At project startup, he provides guidance to the project Seattle, Washington manager in setting up a quality control program to ensure that the completed Years of Experience' project will meet the client's goals and expectations with regard to ' documentation, schedule, and cost. In concert with the Discipline Lead 32 appropriate to the project, Allen participates in the interim quality control Years with Tetra Tech: ' reviews. Prior to the release of final documents, either a report of study results or 31 design and construction drawings, Allen reviews the documents for consistency with design criteria and standards as well as contractual obligations. Key Areas of Experience: ' EXPERIENCE ■ Mechanical engineering (QUALITY ASSURANCE ■ Pump and Piping Systems ' Quality Assurance: Review of Construction Documents ■ Quality AssuranceHVAC —Brightwater Conveyance System, King County, Washington Systems ' —Blaine Wastewater Treatment Plant, Blaine, Washington ■ Energy Conservation —College Place Wastewater Treatment Plant, College Place, Washington Analyses and Design —Warm Springs Wastewater Treatment Plant, Warm Springs, Oregon ' —Wastewater Treatment Plant, Government Camp Sanitary District, Oregon ■ Heat Recovery —Wilburton Siphon Upgrade Project, Bellevue, Washington —Kimball Creek Pump Station, Snoqualmie, Washington ■ Hydraulics and —Eastside Interceptor, Bellevue, Washington Compressed Air —Stanwood Sewage Pump Station, Stanwood, Washington —Columbia Slough Consolidation Conduit, Portland, Oregon ■ Value Engineering ' —West 650 Pressure Zone transmission/distribution system piping, reservoir, and ■ Wastewater Treatment booster pump, Aberdeen, WA Facilities ■ Bus Maintenance Facilities ■ Office Buildings 1 TETRA TECH, INC. Approximately 220 additional project construction document reviews as of 8/l/06. Quality Assurance: Reviews of Engineering Reports —Wastewater Treatment Plant Study, Coupeville, Washington —Wastewater Treatment Plant Engineering Report, Olympus Terrace Sewer District, Washington —Sewer Facilities Plan, Aberdeen, Washington —Northgate Thornton Creek Modeling, Seattle, Washington —Spiritbrook Park Drainage Improvements, Bellevue, Washington — Approximately 90 additional project engineering report reviews as of 8/l/06. MECHANICAL DESIGN Snoqualmie Ridge/Kimball Creek Pump Station, City of Snoqualmie, WA,1999 Lead Mechanical Engineer, provided HVAC design for a new 10 mgd pump station. The station includes two 3500 gpm pumps at 90 feet of head with room for a third pump for future expansion. King County Kenmore Interceptor, Kenmore, WA,1987 Mechanical Engineer, provided hydraulic design for sluice gates and operators for 2,900 linear feet of two parallel 132- inch-diameter storage/conveyance lines. King County Juanita Bay Force Main and Pump Station Modifications, Kirkland, WA,1984 Mechanical Engineer, provided design and PS&E for 13.8-mgd pump station modifications. Harbor Resorts Wastewater Treatment Plant Upgrade, Stevens Pass, Washington, 2002 Lead HVAC designer for facility upgrade that included complete replacement of all process, mechanical and electrical ' systems. HVAC work included electric boilers, hydronic pump/piping system, unit heaters and air handlers for approximately $4 million total construction cost upgrade. ' Glenwood Area Sanitary Sewer Improvements Design, City of Eugene, Oregon,1994 Mechanical Engineer for an 18 mgd pump station, 4,000 feet of 24-inch gravity sanitary sewer and 500 feet of 60-inch gravity sanitary sewer and 24-inch and 14-inch force mains. The pump station included variable speed drives, standby ' power, odor control, chemical storage and noise control. Wastewater Treatment Plant, City of Blaine, WA,1999 Lead Mechanical Engineer, provided design of heating and ventilating system including odor control for 5-mgd treatment plant. Ventilation designed per NFPA 820. The 9,280 cfm odor control system utilizes wet, single stage, I packed bed absorption system. Chemicals used included sodium hydroxide and sodium hypochlorite. Wastewater Facilities Improvements, City of Hoquiam, WA,1983 ' Lead Mechanical Engineer, provided design of nine pump stations ranging in capacity from 0.3 to 3.9 mgd, including piping systems, ventilation and odor control. LJ A. Bellew, Page 2 1 ITETRA TECH, INC. DAVID BLOXOM, P.E. Title: Vice President Electrical Dave Bloxom is responsible for overseeing the design and management of all Division design of electrical and control systems for our engineering projects. Duties Project Role: ' include providing technical direction on projects for municipal clients. Dave's projects have ranged from small studies to full-scale design and implementation, Project Manager including over 45 wastewater and over 30 water system projects. He has also Education: been responsible for designing, testing, supervising the installation and start up of Perry Institute of Technology, electrical, instrumentation, telemetry, control and data management information Instrumentation and Industrial ' systems for water and wastewater treatment facilities in Washington, Oregon, Idaho, Montana, California, Texas, Arizona, Arkansas, Virginia, and Florida. Electronics, 1981 Oregon State University, In each of the following projects, Dave was responsible for the project Transfer Program, 1985 -1986 ' management and quality control for complete design of the electrical and Registration/Certification: instrumentation systems. He managed staff that conducted site visits to verify equipment conditions, verified accuracy of as -built drawings, and Professional Engineer: WA, 1992 'existing reviewed the condition of existing wiring as well as all existing electrical equipment. Professional Engineer: OR, 1993 On each of these project, Dave also directed the design of the facilities to confirm conditions that would require specific electrical system designs to comply with Office: NEC, NFPA 820, and other Codes. Bothell, Washington Years Experience: EXPERIENCE of 25 King County Matthews Park Pump Station Flow Meter Upgrade, Seattle, ' WA, 2001 Years with Tetra Tech: David was the Principal -in -charge for the designs to replace two existing flow- 11 measuring devices with electromagnetic flow meters. The design involved specification of instrument mounting, connection, and cabling. Also involved, Key Areas of Experience: was the interfacing analog flow rate and pulse totalization signals to the existing ■ Design of electrical and ' control panel and SCADA system. In addition, the design added two new flow control systems totalization displays to the existing control panel. ■ Wastewater and water Sewer Lift Station and Telemetry System, City of Fife, WA, 2003 system projects David was the principal in charge of the design of a fiber optic communication based PLC telemetry system expansion. The project required ECS to design a • Testing, supervising the PLC based SCADA and control system for 5 new sewer lift stations. These lift installation and start up of stations will communicate over a new city wide fiber optic network with City Hall electrical, instrumentation, and the Public Works Shops. telemetry, control and data management information Inglewood Corridor Lift Station; Sammamish Plateau Water/Sewer District, systems 1998 ' - D.Bloxom, Page TETRA TECH, INC. David was responsible for the electrical, instrumentation, and telemetry design for this 4 pump, dry well/wet well sewage lift station. The lift station was designed to pump peak flows of 8.0 MGD, utilizing dry -pit submersible pumps of two sizes to handle varying flow ranges. The electrical design included a new service into the station and a stand- by- generator. The controls design included the installation of a new PLC based control panel, which was connected to a new telemetry RTU, expanding the District's existing water/sewer telemetry system. King County Lake Ballinger Pump Station Vibration & Temperature Monitoring Equipment Replacement, Richmond Beach, WA, 2002 David served as the Principal -in -charge for the instrumentation and installation designs for the replacement of the sensors and monitoring equipment at the two pump station sites. ECS was responsible for the specification of temperature and vibration sensing probes to be mounted on pump and motor bearing housings for the purpose of monitoring bearing wear and predicting eminent bearing failure. The team proposed a state of the art vibration and temperature monitoring equipment to interface with the sensing devices, analyze the input signals, and provide alarm signals to existing annunciation equipment and SCADA systems. The system was designed to provide two programmable alarm levels, WARN and TRIP, as well as individual display, for each point monitored. Pumping Station Upgrade; City of West Linn, OR,1999 David served as principal -in -charge for the electrical design of the upgrade to an existing water pumping station, and the electrical design of a new pumping station. The existing pumping station required a complete electrical and telemetry system upgrade. The new pumping station required a new electrical service, stand-by power generator, and a feeder system to power the existing station. Wastewater Treatment Plant; Town of Mattawa, WA,1998 David served as principal -in -charge for the electrical design of the new wastewater treatment plant for the Town. The plant included a new influent pumping station, influent screen facility, aeration system, sludge processing, and effluent disinfection. The electrical design included a new stand-by power generator to operate the plant in the event of a utility power outage. D.Bloxom, Page :- r TETRA TECH, INC. DOUGLAS D. GENZLINGER, P.E. Doug Genzlinger is a senior civil engineer with a pipeline emphasis and 29 years experience at Tt/KCM. He has managed the design and construction of wastewater, Title: water, and drainage improvement projects. During the late 1990s he was Lead Associate/Senior Civil Engineer Engineer and Project Manager for several on -call contracts as well as major sewer rehabilitations and extensions for the Southwest Suburban Sewer District and has Project Role: been District Engineer for several local sewer and water districts, overseeing all QC: Pipeline engineering aspects for each district. Education: Doug was Project Manager and Lead Engineer on the City of Fife's LID 98-2, B.S., Civil Engineering, which provided sewer infrastructure to service two-thirds of the City and was University of Washington, 1975 recently Project Manager for Washington State Parks Dash Point pump station upgrades. He was Project Manager for design and construction of eight miles of Post -graduate study, trunk sewer in the Alderwood Water & Sewer District, a $10 million project that Mechanical Engineering, included 40-foot deep open cut pipelines, micro -tunneling, pile -supported pipelines, University of Washington, 1976 and extensive construction and restoration work within Snohomish County wetland Registration/Certification: areas. Other significant projects include the Lander CSO for King County and the City of Seattle's South Hanford Street/ Bayview Street Tunnel and Diagonal CSO. Civil Engineer: WA, 1981 EXPERIENCE Office: Seattle, Washington LID 98-2, City of Fife, Washington, 2003 Project Manager for design of 5 wastewater pump stations, 3 miles of forcemain and Years of Experience: 2.5 miles of gravity interceptor. The $11 million project provides sewer 30 infrastructure to service two-thirds of the City of Fife and lifted a 4-year building moratorium. The project included multiple contracts, dewatering, and high traffic Years with Tetra Tech: areas. Challenges included construction of large -diameter HDPE pipe in a heavily 29 traveled roadway with a substantial number of utilities. Contract 3 constructed deep sewers in soft soil conditions using precast concrete slabs to stabilize the trench Key Areas of Experience: bottom. ■ 30 years of Pipeline Design King County Soos Creek Area Pump Station D and Pipeline D Project, 2005 ■ Open -cut, micro -tunneling, Project Manager for predesign of approximately 4 miles of forcemain/gravity sewer pile -supported pipelines and a 26 mgd pump station. The project included survey and geotechnical explorations, permit and easement assistance, community relations, a LEED ■ Extensive construction charette, validation of flow information, and preparation of design documents to engineering experience 30%. South Snoqualmie Hills Sewer, City of Snoqualmie, Washington, 2004 Project Manager for design of 5,400 feet of sewers, including 2,850 feet of 10-inch sewer in the South Snoqualmie Hills and 2,550 feet of replacement 15-inch sewer in ' D. Genzlinger, Page 1 TETRA TECH, INC. Historic Snoqualmie. Included was the demolition of pump station #5 and the sealing of 10 manholes. Alderwood WWD Swamp Creek Trunk Sewer Project, Kenmore, WA,1996 Project Manager for the predesign report, design, preparation of contract documents, and construction administration and inspection of an 8 mile sewage interceptor along a critical wetland area. Many utilities in the street had to be removed and replaced in areas where the trench depth exceeded 30 feet. Unique aspects of the project included construction of pile supported pipelines, 40-foot deep open cut construction, and two 42-inch microtunnels under I-5 and I-405. King County Swamp Creek Trunk Sewer Extension, Kenmore, WA, 2002 Project Manager for design and construction of 4,300 feet of 36-inch to 72-inch diameter King County trunk sewer. Of the 4,300 feet of trunk sewer, 1,100 feet was tunneled in three sections. The first section was a 48-inch tunnel beneath the existing Swamp Creek Bridge at NE 92nd Street. The 48-inch tunnel bisected between existing bridge piles spaced approximately 6 feet on center with only three feet of cover below the stream bed. Two other sections of 72-inch diameter line were installed using a Lovat TBM. Design included the use of ground penetrating radar to locate logs and detect changes in ground characteristics. Southwest Suburban SD Sewer Rehabilitation, Burien, WA,1999 Project Manager for the evaluation of the District's existing sanitary sewer collection system, preparation of a Preliminary Engineering Report and the design of Phase I Plans, Specifications, and Engineer's Estimate (PS&E). The analysis included a review of pipeline videos, as -built design records, geotechnical data, and survey mapping. The Preliminary Engineering Report proposed the rehabilitation or replacement of 17,000 if of sewer mains ranging from 8- to 24-inch-diameter. Design constraints included wetlands, peat deposits, high groundwater, buildings, and landscaping improvements over the existing sewer main, and pipeline segments over 15 feet deep. The design varied to fit the problem, using conventional open trenching, pipe burst replacement, and cured -in -place pipe rehabilitation. Both construction phases included three rehabilitation methods in the construction specifications. King County Lander Combined Sewer Overflow (CSO) Separation Project, Seattle, WA,1991 Mr. Genzlinger was Project Leader for this $18 million project. Design elements included a route study, flow projection, and pipe sizing for sanitary collectors and interceptors ranging in size from 24- to 96-inch diameter. The SWMM model was used to optimize pipeline design and network storage through flow -diversion structures interconnecting parallel trunk sewer systems for the maximum reduction in combined sewer overflows (CSOs). Phase I of the project included 3,700-ft of 96-inch dia sanitary trunk sewer, an outflow regulator station, and a flow -diversion siphon. Construction included 1,500-ft of 48-inch interconnect sewer between the Lander trunk and the Hanford Street sewer to maximize storage between the two basins. The work required extensive street restoration and utility I coordination, as all sewer improvements followed street rights -of -way. Southwest Suburban SD Sewer Rehabilitation Project, Burien, WA,1999 ' Project Manager overseeing the rehabilitation design for 2 miles of 8" to 36" sewer lines in the White Center area. Rehabilitation methods included pipe bursting and cured -in -place liners. D. Genzlinger, Page 2 ' ' TETRA TECH, INC. B RYAN KAWAM U RA, P.E. Title: ' Electrical Engineer Bryan has been involved in electrical and control systems engineering since 1997. project Role: Bryan has experience in electrical and control system design and implementation ' for a wide variety of municipal and industrial projects. This experience includes Project Manager development of electrical, control system and software projects, and has included Education: field investigation, as -built drawing, control system panel layout, control UO BS, Electrical Engineering, ' wiring development, system check out, and production. Washington State University, EXPERIENCE 1997 ' Water and Sewer SCADA System; Alderwood Water District, year Registration/Certification: Engineer: WA, Bryan was responsible for the PLC/VFD communications design for the study of 2003 ' the District's water and sewer SCADA system. The system was installed to monitor and control all of the District's water pump stations, reservoirs, and water Office: master meters. The system was also designed to monitor the sewerage system, Bothell, Washington ' including the Wastewater Treatment Plant. ECS was involved in several workshops with the Districts during the course of this project. Years of Experience: ' Sewer Lift Station PLC Programming, Cross Valley Water District, 9 Bryan was responsible for the PLC and telemetry software development, system Years with Tetra Tech: configuration, start-up and commissioning for a new duplex lift station for the 8 District. The PLC controlled the pump and wet well level as well as monitoring all of the station parameters including the stand-by generator. The telemetry Areas of Experience: system communicated with the District SCADA computer that was also m Wastewater and water programmed by Bryan. The approximate cost of this project was $150,000. system projects City of Tacoma — Pump Station PLC/SCADA Standards, 2001 Bryan was responsible for the technical input for this ECS project. The City was Design control systems of electrical and ' working with a design consultant to prepare Design and Construction standards for all new City sewage pump stations. Bryan assisted the City by attending ' meetings with the City staff and consultant and providing the technical review of the station standards proposed by the City's consultant. Bryan's comments advised the City on the applicability of the consultant's recommendation as it ' applied to the SCADA master computer upgrade, being accomplished by ECS, and future projects being considered by the City. Transfer Station and Cedar Hills Monitoring SCADA System, 2004 Bryan was responsible for the programming and construction administration for the a new countywide SCADA system for the Solid Waste Division of King County Department of Natural Resources. The project goal was to develop a SCADA system using multiple communications methods such as radio, Ethernet, and cellular that would allow County personnel to monitor remote sites throughout the Cedar Hills Landfill, remote landfills, and remote transfer stations ' B. Kawamura, Page 1 TETRA TECH, INC. for process and security alarm conditions. The Master Plan included SCADA system hardware and software options, implementation options, cost estimates comparing options and a recommended final system configuration. Wastewater SCADA Graphic User Interface Whatcom County Water District No. 10,1999 Bryan was responsible for the software development, system configuration, start-up and commissioning of the District's SCADA system. The SCADA system monitored the District's 24 lift stations, as well as their water system. The original cost of the telemetry system was over $250,000. The cost of the upgrade accomplished by Bryan was $35,000. King County South Plant/Pump Station Communcations Predesign, 2001 Bryan was responsible for the technical study of potential communications pathways between the existing South Plant SCADA system and all of the remote PLCs using the available communications protocols and current technology. Some of the options that were explored during the study were DSL/ISDN Ethernet connections and Ethernet over standard 2 or 4 wire leased telephone lines. Necessary hardware was identified, and a cost analysis was done for each option. A predesign report recommendation was made based on the overall costs and the expected reliability of each option. HVAC and Electrical Upgrades to the King County East Pine Pumpstation, 2004 , Bryan contributed to the design of a complete power, instrumentation, and controls upgrade to a 1970's era pump station. He reviewed County design standards, developed schematic diagrams, layout drawings, and P&ID's. King County opted after the 60% submittal to complete the remainder of the design in house. , Sewer Lift Station and Telemetry System; City of Fife, WA, 2000 Bryan was responsible for the design of an ethernet spread spectrum radio communication based PLC telemetry system expansion. The project required ECS to design a PLC based SCADA and control system for 5 new sewer lift stations. ' These lift stations will communicate over a new city wide network with City Hall and the Public Works Shops. 1 B. Kawamura, Page,- 1 1 ' TETRA TECH, INC. i SETH ORGAIN Title: ' Architectural Designer Seth has been practicing architecture for over 5 years. Seth has gained experience project Role: in architectural design, project coordination, documentation, permitting, and ' construction management while working on a broad range of project types. This Architectural Production experience includes single family homes, multi -unit residential, commercial Education: ' interiors, government facilities buildings, and museums. Bachelor of Architecture, EXPERIENCE Virginia Polytechnic Institute and State University, 1999 ' King County Metro Atlantic/Central Base Expansion, King County DOT, Registration/Certification: Washington NA Multi -phased, multi -facility bus base expansion project. This $94 million project ' includes maintenance facilities, operations and communication building, whole Office: site programming and planning, and full street right-of-way improvements. Seth Seattle, Washington has been providing project support on the Operations Building, a multi -tenant facility including driver dispatch, driver support, training, and Metro Police Years of Experience: station functions. Seth has been responsible for production of conceptual design 5 documents including 30% submittal drawings, conceptual sketches, cost estimates, and progress summaries. Seth has also provided research and analysis Years with Tetra Tech: of multiple sustainable building systems in concert with project and LEED 1 requirements. Seth is currently responsible for coordinating the mechanical Key Areas of Experience: ' engineers, energy modelers, and architects in pursuit of advanced energy efficiency goals. ■ Construction and Sewer Lake Line and P.S. No. 4 Replacement Project, City of Mercer Island, permitting documentation Washington ■ Multi -disciplinary Tetra Tech is responsible for the preliminary design development, permitting and final design documents to replace approximately 9,000 feet of sewer line located coordination and collaboration in Lake Washington and relocation of an existing sewer pump station. u LEED analysis and ' Construction is estimated to begin in mid-2007 and projected to cost approximately $12 million. Seth is working with the structural and civil documentation engineers to design the Controls Building which will house the electrical and m Architectural design control equipment as well as a standby generator. Seth is responsible for ' production of all architectural documents and estimating. Juneau Seawalk, City of Juneau, Alaska The Juneau Seawalk is a pedestrian way that will provide access along the entire length of Juneau's waterfront and link disparate neighborhoods. Seth worked closely with the Juneau based project manager and lead architect to develop the Seawalk's guardrail and lighting design. Seth then produced civil, structural, and architectural construction drawings for the first phase of construction. I S. Orgain, Page 1 ' TETRA TECH, INC. THOMAS ROTH, R.A. Title: ' Senior Architect Tom Roth has a long history of working with public agencies. His client project Role: experience includes design work for a variety of local organizations such as the City of Mercer Island, Issaquah Public Works Department, King County Parks QA: Architecture and Recreation, Pike Place Market PDA, Covington Water District and the City Education: of Seattle. His work for the City of Seattle includes several projects for Parks and Master of Architecture, Univ. ' Recreation such as the Cal Anderson Park Shelterhouse, the sister project to of Washington, 1976 Tt/KCM's design for the undergrounding of the park's reservoir. BAED Architecture, North ' Since joining Tetra Tech Tom acted as project architect for a new 25,000 sf Carolina State University, 1972 Administrative Office and Laboratory Building to be constructed at King County DNR's Renton Treatment Plant. This significant project is expected to receive a Registration/Certification: ' LEED Silver rating. It incorporates many innovative sustainable design concepts Architect: WA, 1978 including the use of reclaimed water and the pre -heating of air using a metal solar Office: wall system. Tom was project manager for the design of renovations to the historic Building 50 at the Puget Sound Naval Shipyard, a future naval museum. Seattle, Washington He also has assisted in Tetra Tech's planning effort for the City and Borough of Years of Experience: ' Juneau, Alaska's new Consolidated Public Works Facility. He is currently 28 working on the design of a major project for Travis Air Force Base. Years with Tetra Tech: EXPERIENCE 1 ' Sewer Lakeline and Pump Station Replacement, Mercer Island, WA, current Key p Areas of Experience: Owner/Project Manager: City of Mercer Island, Anne Tonella-Howe, (206) 236-7687 ■ Public agency architecture Tom is managing Tetra Tech's architectural design of the project's Control n Renovation design Building. Located in a city park in a residential area, much of the effort is focused ' on providing an aesthetically -appropriate structure that is both utilitarian and a good neighbor, with an emphasis on sound control and appearance. ' King County South Treatment Plant Administration Building, Renton, WA, current Project architect for this 25,000 sf new office and laboratory building designed to achieve a Silver LEED standard. The building will accommodate several different departments, host business meetings, provide spsace for educational programs and tour groups and will include a state-of-the-art wastewater laboratory. The innovative steel and brick building features numerous green building technologies including a Solarwall pre -heating system, flushing of toilets with reclaimed water, interior natural daylighting, utilization of process waste -heat, high thermal performance, and environment -friendly materials. IT. Roth, Page 1 TETRA TECH, INC. Renovations to Building 50, Puget Sound Naval Shipyard, Bremerton, WA, 2006 Project Manager for renovations in design/build contract with JKT/PCL to an historic structure. Tom worked closely with the contractor and Navy personnel to plan improvements. Work included roof replacement and restoration or replacement of selected architectural details, installation of a new internal structural steel support system, fire sprinkler system, lighting and plumbing, external foundation drainage system and other improvements. With construction complete, the building has been turned over to the City of Bremerton for use as a Naval museum. Alki & Licton Springs Comfort Stations, Seattle, WA, 2005 Tom was architect with Thomas Roth & Associates (TRA) for these two projects located in different Seattle Parks. The Licton Springs project involved a complete renovation and partial expansion of the park's shelterhouse, including new restrooms and volunteer work crew area. The Alki project included the design of new park restroom facilities and the attached garage for the Parks Department's new beach -sweeper. All of this work was coordinated with the construction of the Alki's new Whale Tail Park Covington Water District Headquarters, Covington, WA 1998 Project architect with Thomas Roth & Associates (TRA) for this new 10,000SF office building with separate fleet vehicle facility and fuel station. In addition to providing district offices, the project included space for a commissioner's hall, cafeteria and kitchen, telemetry center and demonstration garden. Work also involved master planning. City Light South Service Center Remodel, Seattle, WA, 2002 Working with City Light administration and representatives of the staff and union, Tom (TRA) planned and designed extensive "gut -rehab" improvements to the line -workers locker rooms, shower and restroom facilities at this sound -end industrial shop and warehouse facility that serves over half of the City Light field crews. In addition to the tenant improvement work, the project included planning for temporary facilities, utilities and resolving seismic retrofit issues. Cal Anderson Park Shelterhouse Project, Seattle, WA, 2004 Tom (TRA) was architect and project manager for this important public project located in the landmark Olmstead - designed Cal Anderson Park. The subject of numerous public workshops and community meetings, the successful project created a focal point and activity center that was badly needed in a troubled park. The design included three half-timbered style buildings, two linked by a curved plaza covered by rows of garden trellis. Fire Station 22 Remodel, Seattle, WA, 2002 Tom (TRA) was architect for the renovation of this Capitol Hill neighborhood fire station. Work included design of temporary facilities used during construction. This project required construction phasing and the addition of temporary facilities to keep fire services in operation throughout construction. His design included the gut -remodel of bunk, locker and shower facilities to accommodate privacy and separate facilities for men and women firefighters; as well as beanery/kitchen renovations and additional storage. New computer work stations, lounge, and weight room for the crew were squeezed into the existing station. It also added new passive solar elements. Seattle Police Department IIS Offices Tenant Improvements, 2005 Tom was responsible for the design and planning of offices for the Seattle Police Department's IIS (internal affairs) Unit. The project, located in Seattle's new Municipal Justice Center, involved department space planning, electronic security systems, reception desk force protection, mechanical and electrical systems improvements and interior design. T. Roth, Page 2 ' TETRA TECH, INC. BARRY A. SCOTT, P.E. ' Barry Scott oversees all water, wastewater, pipeline and pump station engineering performed at Tetra Tech's Northwest offices and has served as lead Title: ' hydraulic/mechanical engineer responsible for all mechanical, electrical, and Vice President hydraulic engineering projects. He has broad experience in the planning, design, and construction of water and wastewater treatment facilities, as well as process layout Project Role: ' and hydraulic structures including outfalls and intakes in lakes, streams, and ocean QC: Pumps environments. His expertise includes corrosion in piping, valves, and pumping systems. Bany's experience has included preliminary design, design, and value Education: ' engineering review of pump stations, storage reservoirs, and pressure and level M.S., Sanitary Engineering, control systems. He has designed pumping systems ranging in size from very small California State University at ' flows to those in excess of 2,000 cfs. Working with our quality assurance staff, he San Jose, 1971 developed design criteria for wastewater pump stations. Prior to joining our firm in 1977, Barry was a senior hydraulics engineer for Bechtel, Inc. His responsibility B.S., Civil Engineering, included design, steady state and hydraulic transient analyses for turbines, pumps California State University at ' San Jose, 1970 and pipingsystems. ystems. EXPERIENCE 40-hour Value Engineering ' Training Workshop King County Brightwater Conveyance System Predesign and Final Design, Registration/Certification: Woodinville, WA, current Tetra Tech Principal in Charge and Senior Engineer; pump station predesign lead. Civil Engineer: Washington, The 170 mgd Influent Pump Station (IPS) is a major component of the Brightwater 1978; California, 1976 ' Conveyance System, which includes a 4 mile long 14-foot influent tunnel and 2.8 miles of force main system to convey wastewater to the WWTP. Tt/KCM led the Office: predesign of odor control for the conveyance system, preliminary hydraulics and Seattle, Washington layout and design of hydraulic structures and pump station. Odor and corrosion Years of Experience: ' control work involved defining odor control criteria, odor control and chemical injection equipment selection, and predesign documents for odor control facilities at 35 four different locations. As part of the Predesign, Tt/KCM civil engineers defined Years with Tetra Tech: the proposed hydraulic connections for the local conveyance systems to the new Brightwater tunnels. 29 King County Regional Inflltration/Inflow Control Program, 2006 Key Areas of Experience: Tt/KCM is part of the Earth Tech Team for the County's 5-Year Regional ■ Pump station, reservoirs, & ' Infiltration /Inflow Control Project. Thirty-two special purpose districts and pressure & level controls municipalities within King County have joined together to reduce 1/I in accordance with the Regional Wastewater Services Plan. Work includes 1/I flow monitoring, Hydraulic transient analysis system modeling, design and construction of pilot demonstration projects, and n VE review of pump development of I/I control policies and design standards. Barry is Deputy Project stations throughout US Manager of this $25.7 million project responsible for design aspects and managing ' local area managers. ■ Wastewater treatment I B. Scott, Page 1 TETRA TECH, INC. North Creek Diversion Project, Bothell, WA, 1999 and 2003 Pump Station and Pipeline: Project Manager responsible for concept development, predesign, and design of a 36 mgd pumping station and five miles of twin 30-inch-diameter force mains. The pump system includes 500 hp pumps, variable speed drives, a complete carbon odor control system, ferric chloride chemical injection system, standby power, lifting equipment and public art. The project included three contracts, preload, pipeline, and pump station totaling over $39 M in construction. Key issues included railroad crossings and paralleling the railroad for approximately 4,000 feet. North Creek Storage Facility: Project Manager for the fast track design and permitting of the associated 6 mg underground sewage storage facility which includes odor control, cleaning systems, and automated controls. Sweyolocken Pump Station, Bellevue, WA, 2005 Principal -in -Charge for Tt/KCM work as subconsultant on the renovation of an existing pump station built in 1963. Tt/KCM provided development of alternatives, predesign of the facility and final design of the odor control, structural, architectural, and technical assistance design services. Pump station capacity will be expanded from 21- to 26-mgd. Improvements include a new wetwell, pumps and motors, electrical power and control systems, and an odor scrubber system. A new emergency generator will be provided in a separate building, and the entire facility will meet Bellevue's sound attenuation requirements. LID 98-2, City of Fife, WA, 2003 Principal -in -Charge for design of five wastewater pump stations, 3 miles of force main and 2.5 miles of gravity interceptor. The area was under a building moratorium until sewage service capacity was increased. King County Soos Creek Area Pump Station D and Pipeline D Project, 2004 Principal -in -Charge for preliminary design of approximately 4 miles of forcemain/gravity sewer and a 26-mgd pump station. The project included preliminary survey and geotechnical explorations, permit and easement assistance, community relations, a LEED charette, validation of flow information, and preparation of preliminary design documents to 30 percent. Kimball Creek Pump Station, City of Snoqualmie, WA 1997 Principal in Charge and lead pump designer. Pumping station pumps flow from new Snoqualmie Ridge development to the WWTP using Hidrostal pumps installed in prerotation basins. Fanno Pump Station and Force Main, City of Portland, OR,1999 Project Manager. The Fanno Pump Station and Force Main Project was designed to replace five existing pump stations and included construction of a gravity bypass sewer to connect the existing gravity sewer to the pump station and construction of a forcemain extending from the pump station site approximately 16,200 feet in length. Tt/KCM's involvement was full design of the pump station and review of the pipeline. B. Scott, Page 2 u f� I I u LORNE BALANKO, PE w� Principal MSc, Civil Engineering (Geotechnical), University of Alberta, 1968 BSc. Civil Engineering, University of Alberta, 1966 Registration —Professional Engineer: Washington 2001. Montana 2001, British Columbia 1974, Alberta 1968 Affiliations —American Society of Civil Engineers. Society of American Military Engineers, Canadian Geotechnical Society, International Society of Soil Mechanics and Geotechnical Engineers American Public Works Association Mr. Balanko has 40 years experience encompassing a broad variety of geotechnical engineering projects and involving terrain and climatic conditions ranging from the Canadian Arctic, Central Plains, Cordillera and Pacific West Coast. The setting of projects in which he has provided geotechnical engineering consultation has ranged from pristine wilderness to heavily developed urban environment. He has used his broad background in terrain assessment, slope stability evaluation, site preparation, and foundation design to provide design and construction guidance for all aspects of public and private developments, both as project engineer and geotechnical project manager of larger project teams. Projects involving sewer and water systems have formed a major part of Mr. Balanko's work experience and range from distribution and collection pipelines and pumping stations for municipal water and sewer works to major treatment plant facilities and facilities upgrades. Many of these conveyance pipeline facilities have involved crossings of water bodies and bog terrain, wherein design and construction considerations for submerged and buoyant conditions applied, and a number have involved large -diameter tunnels installed by both open -cut trench and trenchless methodologies. Recent projects in which he has been involved in a senior review and/or project management capacity include: NE Sunset Boulevard Improvements with Kevin Goss and the City of Renton, the Mercer Island Lake Line with TetraTech/KCM; the Renton Treatment Plant—Dewatering Building Expansion; Lacey Olympia Tumwater Thurston (LOTT) Wastewater Alliance Hawks Prairie satellite treatment plant project, with associated conveyance system and upgrades to the Martin Way Pump Station, the Friday Harbor Wastewater Treatment Plant Improvements; the Pe Ell Water Treatment Plant Improvements; the Chelan Wastewater Treatment Facility Improvements, and the West 540 and West 650 Pressure Zone water mains for the Bremerton Water system. NE Sunset Boulevard Interceptor —Phase II Improvements, Renton, Washington. Mr. Balanko served as the Principal -in -Charge and Review Engineer for the geotechnical engineering investigation that HWA provided for the design and construction of new Phase II Improvements to the NE Sunset Boulevard Interceptor in Renton, Washington. Project limits extended along NE Sunset Boulevard between Union Avenue NE and Ilwaco Avenue NE (a distance of about 4,800 feet), and along Duvall Avenue NE from Sunset Boulevard to SE 100th Street (a distance of about 3,000 feet). The project included the design and construction of sewer improvements comprising replacement and upsizing of the system, and extending the system northward on Duvall Avenue NE, a total length in excess of 7,800 feet. Since all sewer alignments extend along busy streets comprising from 2 to 5 lanes of roadway, construction -period traffic disruptions were a significant consideration, along with the costs of dewatering and restoration of trenched areas if conventional open excavation methods were to be employed. In consideration of reduction of these potential adverse impacts, HWA's investigation was tailored to evaluate trenchless technology methods such as pipe -bursting, directional drilling, and pipe jacking. Thirteen borings were completed along the alignment segments employing hollow -stem auger drilling methods and sampling via the Standard Penetration Test method. A number of the borings were situated within the old trench limits to permit evaluation of the backfill properties in regard to pipe -bursting considerations. Piezometers were installed in a couple of the borings to permit measurement of long-term ground water conditions and variations with respect to construction considerations. A variety of subsurface materials were encountered in the borings, ranging from pavement structure overlying trench backfill (typically sand and gravel) materials to native recessional outwash, Vashon till, and advance outwash native deposits. Our detailed geotechnical report summarized the subsurface conditions along the alignment sections, and provided recommendations for pipe -bursting methods, open -cut trenching, construction dewatering, pipeline bedding and backfill materials, compaction requirements, pipe loading and design considerations, and jacking and recovery pit design. Mercer Island Sewer Lake Line —Phase III, Mercer Island, Washington. Lorne served as senior design engineer for HWA in provision of geotechnical engineering services in support of the proposed Sewer Lake Line Phase III replacement project in Mercer Island, Washington. For this project the City of Mercer Island plans to replace V, HWAGEOSCIENCES INC Geotechnical & Pavement Engineering . Environmental, Engineering. & Ground Water Geology . Material Testing & Inspection sanitary sewer lake lines along the north and west shores of the island, and will comprise a combination of gravity and force mains in water depths ranging from 10 to 25 feet. The project is anticipated to go to construction in 2007 and will entail some 7, 500 feet of gravity sewer main pipeline, 5,750 feet of sewer force main, and 6,900 feet of side sewers tying in residential properties along the shoreline. A new pump station is also planned and will be constructed on WSDOT property adjoining the 1-90 Bridge. The pump station will extend to in excess of 50 feet in depth, because of gravity flow considerations, and the lines will be buried typically 4 to 5 feet below lake bottom. The lines are anticipated to comprise ductile iron pipe ranging in size from 8 inches for side sewers to 16 inches for the gravity sewer main. Following a preliminary report regarding seismic vulnerability assessment of the proposed improvements, based on available geotechnical information in the area, HWA performed a geotechnical investigation of soil conditions along the proposed alignment and at the pump station location. The investigation was largely undertaken from a barge with hollow -stem auger equipment and entailed 13 boreholes spaced relatively uniformly along the pipeline alignment. Additionally, 7 Vibracore sampling locations of lake bottom sediments were performed to characterize materials and assess potential contaminant presence relative to offshore disposal regulations in Puget Sound. HWA's report included discussions of soil liquefaction potential, submarine slope stability, potential settlement issues for localized areas of lake bottom comprising peat/organic deposits, and trenching and backfilling issues and requirements. Because of the very substantial depth of the pump station, considerable design review and input was required with respect to deep excavation, shoring and dewatering considerations and tie-in of lines between the pump station and offshore lines. LOTT Wastewater Project, Lacey, Washington. Principle -in -charge of a geotechnical study for a wastewater treatment facilities project by the Lacey Olympia Tumwater Thurston (LOTT) Wastewater Alliance. The proposed facilities consist of a new Hawks Prairie Satellite Reclamation Plant, improvements to the existing Martin Way Pump Station, and conveyance lines. The raw sewage conveyance line from the pump station to the plant traverses along the East Martin Way roadway embankment adjoining a wetland area, and included a trenchless crossing. The reclaimed water conveyance line from the plant to the outfall site also entailed trenchless road crossings at East Martin Way, and at the intersections of Britton Parkway and Marvin Road. A preliminary geotechnical engineering assessment of the general area of the facilities was performed and a report was prepared outlining general geotechnical conditions and design considerations for the siting and design of the facilities. Detailed site and location -specific geotechnical investigations for the facilities were then performed. Separate reports were prepared for the Hawks Prairie Satellite Reclamation Plant site and various plant components, for the proposed improvements to the Martin Way Pump Station, and for the conveyance lines between the pump station and plant and from the plant to the outfall location. Recommendations were provided for foundation support for the various structures and treatment facility units on both the plant and pump station sites. Earth and potential ground water pressures and dewatering needs for buried facilities were discussed, and recommendations and guidelines for site grading and drainage considerations, for open -trench and trenchless construction of the underground conveyance lines, and for roadway and parking lot pavement development, were also provided in the reports. Marysville Trunk F to A Sewer Intertie, Marysville, Washington. The City of Marysville planned to install approximately 5,000 feet of new sewer paralleling a stream channel, and crossing at two locations near the ends of the project. Served as project manager for a detailed geotechnical engineering investigation delineating subsurface soil and ground water conditions along the alignment, and undertook preliminary dewatering evaluation for construction of the sewer pipeline. Results of the investigation and evaluation was included in a comprehensive report, with recommendations for alignment setback from the stream, trench evaluation and dewatering requirements, trenchless installation considerations for the crossings, and recommendation for pipe bedding and backfill. Bremerton Water System Improvements, Bremerton, Washington. Principal in charge of geotechnical investigations and engineering analyses for proposed 1 MG above -ground reservoir, pump station, and over 5,000 feet of transmission line, comprising part of the West 540 and West 650 Pressure Zones of the Bremerton Water System. The investigations comprised both test pit and boring explorations, which revealed that the site is underlain by glacial soils and bedrock; the latter at shallow depth in places. Recommendations were provided for seismic considerations, reservoir and pump station foundations, trench dewatering and excavation including excavation in bedrock. Potential for slope instability was assessed and recommendations provided for suitable mitigation measures, where the lines might be adversely influenced. R� Ii1NA GEOSCIENCES INC. Geotechnical & Pavement Engineering . Environmental, Engineering, UM, 1 & Ground Water Geology 9 Material Testing & Inspection I 1 L� LI STEVEN E. GREENE, LG, LEG Senior Engineering Geologist MS, Geology, University of Idaho BA. Geology, University of the Pacific BS, Business Administration, University of the Pacific Registration —Licensed Geologist: Washington 2002; Licensed Engineering Geologist: Washington 2002 Affiliations —Northwest Mining Association (NWMA), Association of Environmental and Engineering Geologists (AEG) Mr. Greene has a masters degree in geology and 25 years of experience as an economic geologist/engineering geologist. Water, wastewater, and stormwater projects have formed a major part of his consulting endeavors. He has conducted geologic investigations and evaluations for projects including plants, pump stations, pipelines, dams, buildings, highway improvements, urban infrastructure, and landslides. Recently, he has worked with Tetra Tech/KCM on the NE 80th Street Sewer Replacement and the Winslow Wastewater Treatment Plant. Steve also worked on the NE Sunset Interceptor with Kevin Goss and the City of Renton. NE Sunset Interceptor, Renton, Washington. Managed and conducted subsurface exploration program in support of the design for new sewer lines along Sunset Blvd in Renton, Washington. Work consisted of a series of shallow borings that were conducted inside and outside of the existing sewer trenchline so that the native soils and the exiting trench backfill could be characterized. This data was used in developing construction design parameters for open cut trenching and pipe -bursting construction methods. NE 80th Street Sewer Replacement, Kirkland, Washington. Managed and conducted subsurface exploration program in support of the design for new sanitary sewer and water lines along NE 80th Street in Kirkland, Washington. Work consisted of a series of shallow borings that were conducted along the proposed alignment to characterize the subsurface soil and groundwater conditions. This data will be used in developing construction design parameters for open cut trenching construction methods. Lake Stevens Wastewater Treatment Facility, Lake Stevens, Washington. Managed and conducted subsurface exploration, and prepared the Earth section of the EIS for a new wastewater treatment facility to be constructed in Lake Stevens, Washington. Work included borehole logging, fault trench mapping , site reconnaissance, and reporting. CSI Brightwater, King and Snohomish Counties, Washington. Participated in the subsurface exploration program along various proposed pipeline routes. Work included bore hole logging and conducting internal quality control on laboratory and field data. Lakehills Pump Station, King County, Washington. Managed and conducted subsurface infiltration testing for the design of an infiltration trench to accommodate facility roof and access area runoff. Work included test pit logging, field scale infiltration testing, and data reporting. Prairie Creek Pipeline Alignment Evaluation, Buckley, Washington. Conducted geologic route reconnaissance to evaluate present alignment conditions and provide recommendations for maintenance, repairs, or reconstruction. ' In addition, a photo -mosaic of the alignment was created for evaluation prior to conducting the ground survey. Denny Way/Lake Union CSO, Seattle, Washington. Participated in subsurface exploration program, logged ' borings and monitored the installation of piezometers. Metro Brick Sewer Rehabilitation, Seattle, Washington. Conducted several sewer lining coring programs as part of the geotechnical investigation of the existing structure prior to renovation. Integrity of the liner materials were evaluated by compressive and tensile strength tests. Where ground water conditions permitted, subsoils adjacent to the sewer were sampled through the liner and evaluated in terms of their engineering properties. ' Black Diamond Wastewater Treatment Plant, Black Diamond, Washington. Participated in the geotechnical investigation along the sewer alignment. Performed on -site monitoring of soil, aggregate and ACP placement during construction of a 10-mile long effluent pipeline connection with Metro. ' Edmonds Wastewater Treatment Plant, Edmonds, Washington. Performed on -site monitoring of soil, aggregate and ACP placement during the construction of a new secondary treatment facility and related inlet/outfall pipelines. V I n H�VA GFOSCIFNCFS INC Geotechnical & Pavement Engineering • Environmental, Engineering. ' & Ground Water Geology • Material Testing & Inspection 11 I I 1 TRIAD ASSOCIATES Bradley T. Freeman, PLS Survey Project Manager Brad Freeman has over 30 years of surveying experience in the Pacific Northwest, six of which included managing his own firm. He has expertise in boundary, topographic, GPS, utility mapping and ALTA/ACSM Land Title surveying. Brad has been with Triad Associates for 18 years and is an Associate of the firm. He is currently the Survey Project Manager for our work with Lake Washington School District, City of Kirkland, Snohomish County PUD No. 1, and RH2 Engineering. Brad is a member of the Land Surveyors Association of Washington and the National Society of Professional Surveyors. Professional Specialties ' Project Management Boundary and Topographic Surveying Public Land Survey System ' GPS Surveying Utility Route Surveys ' Project Experience City of Renton Downtown and Edmonds Avenue Sewer Extension Projects Lake Washington School District Projects, Redmond, WA City of Kirkland Real Property Data Development, Kirkland, WA Asarco Remediation Project, Tacoma, WA Snohomish County Public Works, On -call Services Snohomish County PUD No. 1, On -call Services RH2 Engineering Misc. Projects, King and Snohomish Counties, WA Beaver Crest Residential Development, King County, WA ' PCC Aerial Mapping Project, Black Diamond, WA Education AAS, Forestry Technology, Green River Community College, Auburn, WA Advance Cadastral Workshop — BLM / US Forest Service course Employment History Triad Associates - 18 years Industry Experience - 32 years Professional Registration and Affiliations Registered Professional Surveyor: WA, ID, MT and AK National Society of Professional Surveyors Land Surveyors Association of Washington ESAAdolfson i LISA ADOLFSON ' Senior Project Manager ' Lisa has extensive experience preparing environmental documents including SEPA/NEPA impact statements checklists and assessments, as well as environmental permit applications. She has over 18 years experience developing and implementing surface water, ground water and stormwater monitoring projects. Lisa has significant experience evaluating impacts associated with all types of municipal projects including transportation, wastewater management, housing development, and ground water management projects. She has also managed restoration projects that utilize funds from liable parties, grants, and volunteer labor. Relevant Experience Education B.A., Geology, Western Soos Creek Area Pump Station D and Pipeline Project, King County, Washington University, 1987 Washington. Lisa served as environmental task lead, assisting King County Wastewater Treatment Division with the development of the Soos Creek Pump Professional Affiliations Station D and Pipeline project. As part of these efforts, Lisa assisted with ' National Ground Water Association alternative screening and development. ment. Environmental considerations such as P wetlands, critical wildlife habitat areas, sensitive stream crossings, and land use Washington State regulations and policies were evaluated for each alternative. The findings of Environmental Health ' Association these efforts were presented at public meetings and documented in the Predesign report. 18 Years of Experience• ' SEPA and NEPA Matthews Beach Pump Station and Force Main Rehabilitation Project, Documentation King County, Washington. Lisa served as project manager, providing Environmental Permitting. environmental documentation and permitting support for both the Matthews Surface and Ground Water Beach Pump Station upgrades and the force main rehabilitation projects. As part ' Quality. of these efforts, Adolfson prepared a SEPA checklist for the force main Construction Monitoring upgrades and identified the permitting considerations associated with the rehabilitation effort. Force main upgrades consist of slip lining the pipeline from a number of insertion points along the pipeline. The force main is located in a residential area adjacent to Matthews Beach Park, the Burke Gilman Trail, and Thornton Creek. For the pump station upgrade, Lisa prepared technical ' memoranda for King County in support of the checklist preparation and assisted with permitting issues. Carnation Wastewater Treatment Facilities EIS, Washington. The town of Carnation contracted with King County to look for suitable locations for a wastewater treatment plant, conveyance pipes and effluent discharge. Lisa ' assisted the City and County with selecting site and routing options for these facilities, as well as preparation of an EIS. River outfall, upland infiltration, and several wetland enhancement alternatives were evaluated for discharge. In addition, Lisa assisted with the preparation of the NEPA Environmental ' Assessment prepared for the project. CI Lisa Adolfson Page 2 Relevant Experience (Continued) Chehalis Wastewater Facilities Plan Environmental Documentation, Washington. Lisa served as project manager for the preparation of the environmental documentation for the Wastewater Facilities Plan for the City of Chehalis. This project included the preparation of an environmental checklist in accordance with the Washington State Environmental Policy Act (SEPA) guidelines, the preparation of an Environmental Report to satisfy the requirements of the Coordinated Environmental Review Process (CERP), as well as the National Environmental Policy Act (NEPA). Key elements to the success of this project included early coordination with regulatory agencies; including the Department of Ecology, determining lead agency status; and determining the potential for a federal nexus. Conveyance System Improvement Project, King County, Washington. As part of the Conveyance System Improvement (CSI) team, Lisa served as project manager evaluating the environmental implications of proposed CSI improvements throughout the King County wastewater service area. As a part of these efforts, Adolfson evaluated the environmental conditions for several conveyance route alternatives in the Hidden Lake and Lake Sammamish Basins. Technical memorandums were prepared describing the current environmental setting, as well as discussing potential environmental and permitting constraints related to construction. Additional technical memorandums have been prepared to address the potential implications of Endangered Species Act (ESA) regulations. Wastewater Resources Management Plan EIS for Cities of Lacey, Olympia, Tumwater, and Thurston County (LOTT), Washington. Lisa served as technical lead for the preparation of the programmatic EIS, which evaluated nine potential options for wastewater management and disposal. Alternatives ranged from on -site sewage systems to reclamation, re -use and marine and freshwater disposal. She assisted with an extensive public information and involvement program for this project, including public workshops, surveys, newsletters, hearings and outreach to community and business leaders. Lisa later served as project manager for the project -specific EIS for the implementation of a reclaimed water treatment plant and groundwater recharge/constructed wetlands polishing in the Hawks Prairie Basin. The Hawks Prairie satellite treatment plant is currently under construction. Swamp Creek Trunk Sewer Project EIS for Alderwood Water District, Washington. Lisa prepared sections of a SEPA EIS for the proposed seven - mile pipeline corridor along Swamp Creek in Snohomish County. She conducted environmental analyses related to surface and ground water quality. Key issues included water quality, fishery, wetland and growth impacts. 11 ESAAd®Ifs®n BENN BURKE Senior Scientist Benn is a Senior Fisheries Biologist with more than 14 years of experience. Benn manages Adolfson's Fish and Wildlife Program. Scientists in Adolfson's Fish and Wildlife Program support a wide range of public and private sector projects by preparing biological assessments, salmonid stream analysis, wildlife inventories, and mitigation planning and designs for wetlands and streams. Benn has been the lead author for dozens of Biological Assessments and has assisted numerous clients with Endangered Species Act compliance. Benn is well versed in stream habitat and analytical procedures and Bern is also trained in wetlands delineation and mitigation design. He has successfully obtained numerous State, Federal, and local permits for a variety of public and private sector clients. Benn is highly experienced working closely and directly with clients, staff from regulatory agencies, the public, and representatives of local governments on large and complex projects. Relevant Experience Education B.S., Fisheries Biology, Honey Creek Stream Restoration, Renton, Washington. Benn served as the University of Vermont project manager for a project for the City of Renton to design and permit a proposed streambank restoration and stabilization project for a reach of Honey Reg Fisherie fScienns Creek that was damaged during a high flow event. The streambank restoration Associate Associate Fisheries Scientist, American Fisheries Society was considered an emergency action due to the potential for damage to the g Y P g existing sewer line and required attaining an emergency HPA to conduct the 14 Years of Experience Fork. Benn prepared the design criteria and mitigation plan for the repair work Fisheries Biology Wetlands Mitigation Planning SEPA and NEPA Documentation Skills and Qualifications Proven project manager for both fisheries and wetlands ' projects. Experienced conducting stream surveys, salmonid habitat studies, and biological assessments for Threatened &Endangered ' fish. Skilled in performing wetland delineations and mitigation design, as well as observing construction activities and permit compliance. Kennydale Lakeline Sewer Replacement Project, City of Renton, Washington. Benn served as the lead fisheries biologist and project manager for the permitting support to replace sections of the existing for in -lake pipeline in Renton's Kennydale neighborhood. The project included significant in -lake fisheries concerns, as well as neighborhood construction considerations. Benn was the primary author of the biological assessment and Corps of Engineers permit materials for this project. Brightwater Wastewater Treatment System Predesign, King County, Washington. Benn coordinated natural resource and fisheries issues for system- wide permits for the Brightwater Treatment System project. He prepared the Corps 404 and Ecology (JARPA) permit application, and coordinated the development of wetland mitigation plans at the treatment plant site. Merrill Ring Creek Regional Stormwater Facility, City of Everett, Washington. Benn served as project manager and senior scientist for the environmental review and documentation for a feasibility study for a planned regional detection factory the Merrill and Ring Creek Basin. Study elements included wetland delineation, electrofishing survey and permit review. J Benn Burke Page 2 Relevant Experience (Continued) Swamp Creek Trunk Sewer Construction Support, King County, Washington. Benn was project manager for environmental support and monitoring conducted during construction of the Swamp Creek Trunk Sewer for King County Department of Natural Resources and Parks Wastewater Services Division. The project involved crossing Swamp Creek. A HPA and ESA requirements required pre -construction snorkel surveys to assess fish use, pre - construction spawning surveys, fish removal and salvage during de -watering and on -going construction monitoring. Madsen Creek Trunk Sewer Biological Assessment, King County, Washington. Benn served as project manager and senior scientist for the preparation of a Biological Assessment for emergency repairs to stabilize a King County trunk sewer line located within the Madsen Creek riparian corridor. Species included chinook salmon, coho salmon, and bull trout. On -call services for Tolt River Filtration Plant for Seattle Public Utilities, Washington. Benn provided on -call professional services in support of ongoing construction at the Seattle Public Utilities Tolt Filtration Plant facility near Carnation, Washington. Benn provided technical assistance regarding implementation of the various mitigation plans and permit conditions for construction and prepared and conducted a site -specific training program for SPU staff that included an overview of permit conditions, wetlands and wildlife resources in the project areas, and temporary erosion and sedimentation control requirements. Swamp Creek Trunk Sewer Biological Assessment, Kenmore, Washington. Benn prepared a Biological Assessment for a proposed 36-inch trunk sewer within the City of Kenmore, Washington for the King County Wastewater Treatment Division. The project includes a crossing under Swamp Creek and construction impacts within a mile -long corridor. Species of interest included chinook salmon, bald eagle, bull trout, and coho salmon. Benn also provided pre -construction surveys and construction monitoring support. Summary of Selected Biological Assessments. Since April 1999, Benn has been project manager and/or senior scientist for over 80 ESA -related biological assessment projects involving the analysis and mitigation of impacts to many ESA regulated species. Projects have included:. • Sound Transit Regional Express Lynnwood Park -and -Ride Project, Washington. • Two City of Everett, Washington Capital Projects • Six Capital Projects for the City of Tacoma, Washington. • Six Capital Projects for the Walla Walla County Department of Public Works, Washington. • 16th Ave South Slide Repair and Culvert Replacement, Des Moines, Washington 1 E LF1 ±E JOHNBARKER Principal Landscape Architect John Barker is a registered Landscape Architect in Washington State. John has ag B A R K E R years experience in landscape architecture and site development and has served as LANDSCAPE manager for large and small public and private projects, as well as a design ARCHrrECTS, PS. project 8e g , P P P 1 8n team project manager on multi disciplinary teams. John has worked with many communities, Parks & Recreation Departments in Washington State, and permitting agencies for approval of sensitive -area trails, recreation, environmental education and wildlife and wetland enhancement projects. Mr. Barker has a strong background in natural area enhancement. Education MLA University of Washington, 1984 Landscape Architecture BS University of Montana, 1973 Geography & Art Experience • Experienced in all aspects of design and construction of schools, playgrounds, trails, neighborhood parks, waterfront parks, public facilities, shoreline enhance- ment/access and site planning projects. • Experienced in a variety of roles ranging from project designer/manger of multi -agency projects to facilitator for community presentations and neighborhood workshops and liaison between volunteer efforts and park municipalities. • Experienced in design of accessible, barrier -free site plans conforming to the Washington State Building Code and the federal guidelines of The Americans with Disabilities Act. • Experienced in integration of architecture and landscape design, and working in multi -discipline design groups. • Extensive shoreline, wetland enhancement and trail experience. Selected Projects O • Mercer Slough Nature Park, Bellevue • McAullife Park Master Plan, Kirkland • Edmonds Waterfront Park and Trail, Edmonds • Meadowdale Neighborhood Park, Lynnwood • Newcastle Beach Park, Bellevue • Baker Park, Seattle • Lawton School Secret Garden, Seattle • Trolley Hill Park & MacLean Park, Seattle • Bradner Gardens, Seattle • CWU Planning & Design Projects, Ellensburg J McElroy Park, Ellensburg w Gleneden Park, Spokane • Ward Springs Park, Seattle • Blaine School Playground, Seattle • Maple Leaf Gardens, Seattle Professional Registration: Washington State License #486 CLARB Certificate #1017 1 11 Years Experience Employed by firm: 16 Total professional experience: 32 Education Post -Baccalaureate Certificate, Noise Control Engineering, Penn State University, 2001 BA, Interior Design, Washington State University, 1973 Registrations and licenses NA Relevant Areas of Experience * 32 years experience in acoustical consulting * 30+ pump stations — variousr upgrades and renovations & new * 3 wastewater odor control facility designs * 4 sewage treatment plant designs Key Projects Soos Creek Pump Pipeline D Julie Wiebusch, INC[ President Role in project: Acoustician Julie has specialized in the field of noise control since 1974 and is a respected leader of acoustics in the Pacific Northwest. Julie regularly performs forensic studies to identify the source of noise or vibration and development of appropriate mitigation; authors reports and technical memos, including the noise sections of EIS and specifications; and represents the design team at Community meetings, presenting environmental noise studies to non -technical audiences. Julie's professional affiliations include: Institute of Noise Control Engineers (INCE), National Council of Acoustical Consultants (NCAC), Acoustical Society of America (ASA), Audio Engineering Society (AES), and the International Communications Industries Association (ICIA). Julie is on the Faculty at Marylhurst University and is also an invited lecturer on Architectural Acoustics at the UW, and for local contractors, architects and professional conferences. Project Experience Soos Creek Pump Station D & Pipeline D; King County, WA, current King County WWTD, David Dittmar (206) 684-1813 Acoustician. Greenbusch evaluated noise impacts associated with potential sites for this new Pump Station. Upon completion of siting, Greenbusch provided the acoustical designs for mitigation of equipment noise, to ensure compliance with WISHA noise exposure levels, and local noise codes. Generator Replacement at 6 Pump Stations; Olympia, WA, current City of Olympia. Thomas Meade (360) 753-8762 Acoustician. Project consists of installation of new on grade generators to replace the generators currently in underground vaults. Recommendations include treatment necessary to mitigate noise and vibration associated with the new generators. • Sweyolocken Pump Station Sweyolocken Pump Station Upgrades; Bellevue, WA, current • Pump Station Acoustical Upgrades King County WWTD, David Dittmar (206) 684-1813 Acoustician. This project was a renovation of an existing pump station located in • Generator Replacement at 6 Pu Bellevue, Washington. Requirements for increased flow at this station resulted in Stations, Olympia the addition of a large generator as well as new pumps and motors. Greenbusch completed a study to document existing neighborhood ambient conditions. Mitigation was then designed to insure community noise levels were not increased due to the renovation project. Recommendations were also provided to mitigate interior noise levels and reduce staff noise exposure levels where possible. Julie Wiebusch was Project Manager for this project. King County Wastewater Acoustical Upgrades, WA, 2003 King County WWTD. John Komorita (206) 296-1423 Acoustician. Greenbusch evaluated noise levels within nine existing King County Pump Stations and developed mitigation treatments to reduce noise levels within each facility to within WISHA 8-hour exposure standards of 85 dBA, where possible. The project was in response to King County's desire to reduce noise exposure levels for staff and to improve radio communication among staff within the facilities. Mitigation treatments included surface finishes and partial barriers around noisier processes. Julie Wiebusch was Project Manager for this project. Julie Wiebusch, INCE - 2 South Treatment Plant Power Co -Generation; Renton, WA, 2005 King County WWTD, Joe Fernandez (206) 263-4670 Acoustician. Greenbusch conducted a survey of the existing ambient noise conditions to establish pre -construction conditions. Noise levels associated with the operation of the co -generation facility were evaluated and community exposure levels were predicted. Mitigation treatments were developed to ensure not only compliance with the City of Renton noise codes, but also minimal impact on the community above ambient conditions. Julie Wiebusch was Project Manager for this project. Work Order -Based Mechanical, Electrical & Process Engineering Services for Minor Asset Management Program; King County, WA, 2005 King County WWTD, Sarah Draper, (206) 684-1299 Acoustician. Greenbusch analyzed community noise exposure and developed mitigation for compliance with applicable Noise Codes. Greenbusch also evaluated noise levels from equipment and developed mitigation to ensure compliance with WISHA noise exposure levels. Included were Matthews Park and Kirkland Pump Stations. Julie Wiebusch was Project Manager for this project. Pacific Pump Station; Pacific, WA, 2005 King County WWTD, Calvin Locke (206) 296-1431 Acoustician. Greenbusch provided the acoustical design for the relocation of the Pacific Pump Station in Pacific, Washington. A noise study was conducted at the proposed site of the Pacific Pump Station Project to establish a pre - construction background noise level for the community surrounding the site. Areas of concern, acoustically, for this project were the environmental noise levels produced by the operation of the new generator. Noise levels within the Pump Station were also evaluated and mitigation measures proposed to reduce staff exposure levels and improve communications. Julie Wiebusch was Project Manager for this project. Juanita Bay Pump Station and Force Mains Upgrade; Kirkland, WA, 2005 King County WWTD, Chris Okuda (206) 684-1285 Acoustician. Greenbusch provided the acoustical design for the relocation of the Juanita Bay Pump Station in Kirkland, Washington. A noise study was conducted at the proposed site of the Juanita Bay Pumping Station Project to establish a pre -construction background noise level for the community surrounding the site. Areas of concern, acoustically, for this project were the environmental noise levels produced by the operation of the new generator. Noise levels within the Pump Station were also evaluated and mitigation measures proposed to reduce staff exposure levels and improve communications, Julie Wiebusch was Project Manager for this project. West Point Treatment Plant Power Co -Generation; Seattle, WA, 2005 King County WWTD, Susan Hildreth (206) 684-1101 Acoustician. Greenbusch conducted a survey of the existing ambient noise conditions to establish pre -construction conditions. Noise levels associated with the operation of the co -generation facility were evaluated and community exposure levels predicted. Mitigation treatments were developed to ensure not only compliance with the applicable noise codes, but also minimal impact on the community above ambient conditions. Julie Wiebusch was Project Manager for this project. South Plant De -watering Building; Renton, WA, current King County WWTD. Joe Fernandez (206) 263-4670 Acoustician. Greenbusch provided the acoustical design for the installation of high solids de -watering centrifuges. Noise levels from similar equipment were measured and formed the basis of our analysis of community impact and internal noise exposure levels. Special glazing was designed to provide adequate mitigation for staff within the control room. Julie Wiebusch was Project Manager for this project. 1 ri Years Experience Employed by firm: 1 Total professional experience: 3 Education BS, Electrical Engineering, Seattle Pacific University, 2004 Adam C. Jenkins Acoustician Role in project: Acoustician Adam Jenkins is an Acoustician with The Greenbusch Group. Adam received his bachelor degrees in Electrical Engineering and Physics in 2004 from Seattle Pacific University. While at Seattle Pacific University, Adam placed an emphasis on researching acoustical phenomenon. This research included his senior paper entitled "Jet Engines: Beyond the Natural Harmonics," which included a detailed analysis of frequency domain sum and difference phenomenon with respect to low- pressure compressors in the modern turbine jet engine. BS, Physics, Seattle Pacific University, Project Experience 2004 Registrations and licenses NA Relevant Areas of Experience 5+ wastewater facilities — various upgrades and renovations & new Key Projects * Mercer Island Pump Station * Klineline Pump Station *Blaine Water Reclamation Facility Bainbridge Island Wastewater Treatment Plant Mercer Island Pump Station; Mercer Island, WA, current Acoustician. Adam is currently conducting a survey of the existing ambient noise conditions to establish pre -construction conditions for this pump station. Noise levels associated with the operation of a new stand-by generator will be evaluated and community exposure levels predicted to determine whether the addition of sound from the generator will increase existing levels to the point of "impact" as defined by the EPA. Recommendations for silencing of the generator noise will be furnished, as appropriate. Greenbusch will participate in a meeting with the City of Mercer Island to discuss the findings and strategize implementation of any required mitigation. Klineline Pump Station; Clark County, WA, current Acoustician. Greenbusch reviewed previous studies to establish baseline, pre -construction conditions at the site. Adam provided the acoustical designs for mitigation of equipment noise, to ensure compliance with WISHA noise exposure levels, and local noise codes. Plant equipment included two stand-by generators, outdoor air condensing unit, pumps, odor control fans, and various HVAC equipment. Blaine Water Reclamation Facility; Blaine, WA, current Acoustician. Greenbusch is currently performing the acoustical design for this project to be located in a noise -sensitive park area within the City of Blaine. The design will include both interior treatment and exterior mitigation recommendations to insure compliance with governing noise codes and WISHA noise exposure levels. Bainbridge Island Wastewater Treatment Plant; Bainbridge Island, WA, current Acoustician. Greenbusch documented the existing wastewater facility's noise sources, through on -site measurements, and created a computer noise model of the site. Potential equipment relocations, replacements, and additions were incorporated into the noise model to predict the resulting noise exposure levels and to guide mitigation recommendations. F, �e �r f� � S U M M E R W I N D / S T 0 N E G A T E LIFT STATION CONSOLIDATION FIELD AVENUE INTERCEPTOR .r, DECEMBER 12, 2006 4010 STONE WAY NORTH, SUITE 300 SEATTLE, WA 98103-8090 www.hcwl.com HAMMOND COLLIER WADE LIVINGSTONE December 12, 2006 Mr. David Christensen Wastewater Utility Engineering Section City of Renton 1055 South Grady Way, 6t' Floor Customer Service Center Renton, WA 98055 TEL: 206.632.2664 FAX: 206.632.0947 ' RE.- SOQ / Proposal for Summerwind & Stonegate Lift Station Consolidation and Field Avenue Interceptor Design ' Dear Mr. Christensen: HAMMOND COLLIER WADE LIVINGSTONE is pleased to submit our proposal to provide the City of Renton ' professional services on your Capital Improvement Project for the Summerwind and Stonegate Lift Stations. We have assembled a successful team comprised of experienced HAMMOND COLLIER professionals with additional staff support from our Subconsultants: ' 0 Landau & Associates will provide Geotechnical Engineering Services Z-Engineering will provide Electrical & Controls Design Applied Professional Services will provide utility Locating Our team is highly qualified to provide analysis, survey, otechnica� utility easements, PS&E, and construction management needed for all phases of this project. Combined, our team has successfully completed over 40 similar integration and rehabilitation projects for lift stations throughout the region. This is demonstrated by our lift station design experience for the Cities of Marysville, Entiat, Auburn, and Bellevue, as well as the Olympus Terrace Sewer District. This experience allows us to apply valuable knowledge to the defined elements of your project, while recognizing that the Summerwind and Stonegate Lift Stations will have unique characteristics and project challenges. Our goal is not only to provide timely technical expertise but also to coordinate effective communication between City staff and our team members so that the final design complies with the City's expectations. HAMMOND COLLIER recognizes the importance of clear and timely communication with the client in all phases of work. From developing a thorough scope of work to conducting a project closeout workshop, we strive to keep clients completely informed of our activities and the progress of your project. ' We appreciate the opportunity to present our qualifications and look forward to serving you in the near future. If you have any questions, please feel free to contact me directly at 800.562.7707 or 206-632-2664. ' Sincerely, HAMMOND COLLIER W E LIVINGSTONE bin Neleon,P.E. ' President SEATTLE WENATCHEE OMAK WINTHROP LAKEWOOD I TABLE OF CONTENTS A. PROJECT APPROACH 1. PROJECT TASKS.........................................................1 2. PRELIMINARY SCHEDULE ........................................ 6 3. MAN HOURS ESTIMATE ........................................... 7 B. PROJECT MANAGEMENT 1. PROJECT MANAGEMENT APPROACH ....................... 8 2. ORGANIZATIONAL CHART ....................................... 8 i ' C. PROJECT TEAM MEMBERS 1. ROLE &EXPERTISE ................................................. 9 2. RELEVANT EXPERIENCE........................................10 3. SUBCONSULTANTS..................................................14 ' D. REFERENCES / E. INSURANCE D1. SEWER LIFT STATION REFERENCES ....................15 ' D2. PROJECT MANAGER REFERENCES ......................15 P, E1. INSURANCE COVERAGE........................................15 HAMMOND COLLIER WADE LIVINGSTONE qp PROJECT APPROACH m m S m m ' m ' m m m m m m m m m m m 1 1 A. PROJECT APPROACH 1. PROJECT TASKS TASK NO. 1— ENGINEERING REPORT RATIONALE: This Engineering Report will evaluate and determine an appropriate solution to provide sufficient wastewater capacity within the infrastructure for buildout, at current land use densities, within the Stonegate and Summerwind lift station service areas. ACTION OUTLINE: The Engineering report willinclude the following subtasks for the development of innovative alternatives that will provide efficient operation and maintenance and include durable, robust and cost effective solutions. Co Determine existing and future service area based upon jurisdictional boundary, site topography and ' municipal code. 0 Develop current land use inventory within the future service area and determine future build out I n I densities for developed and under developed areas within service area boundary consistent with current land use designations approved by City of Renton. Determine low flow, average daily flow and peak flow rates based upon build out conditions and current land use utilizing City of Renton's General Sewer Plan unit flow. Corroborate flows with available hydraulic modeling information provided by the City of Renton. Conduct a brainstorming workshop to develop alternatives to provide sewer service. This workshop would facilitated by consultant and include the proposed design team and City staff. ■ The brainstorming workshop would be a one day meeting conducted at the consultant's office. ■ It will establish goals and objectives for the proposed project. ■ An open sharing of concepts and alignments will be conducted. ■ Then the concepts will be reduced to three feasible alternatives in addition to the City's current alternative. ■ Trenchless Technologies will be evaluated where pipe replacement is proposed. Since much of the existing sewer is within developed roadways, Pipe Bursting may be appropriate but will depend on the number of sidesewer connections along the alignment. All four alternatives and alignments will be appropriated sized to accommodate the build out design flows. Cost estimates will be generated for the four alternatives. A decision matrix will be generated to develop a solution which provides the greatest cost/benefit to the City. The process, facts and findings, conclusions, and recommendations will be summarized in a written report for the City's consideration. TASK LEAD: Robin Nelson, P.E. — Hammond Collier HAMMOND COLLIER i WADE UVINGSTONE QP �J L A. PROJECT APPROACH TASK NO. 2 — DESIGN DEVELOPMENT RATIONALE: This task will provide the necessary physical characteristics, site constraints, and design engineering to develop 30% PS&E. ACTION OUTLINE: The Design Development phase will include all necessary field work and investigations to accurately depict topography, existing utility locations and depths, soils characteristics, and right of way. This work will include the following: Provide geotechnical support to evaluate sub surface conditions at the proposed pump station site. These services would include one boring at the proposed pump station site and provide random borings along the proposed forcemain alignment ' and gravity sewer improvements to provide data on soil type and presence of groundwater. The Geotechnical consultant will prepare a boring log with characterization of soils column, presence of ' groundwater, and pertinent observations during drilling. The geotechnical consultant will prepare a technical memorandum discussing findings and conclusions developed from site observations, underlying materials characterization, and surrounding area. IProvide detailed utility locates to determine location and depth of underground utilities within the right of way within the project limits. This work will be provided by Applied Professional Services. This ' subcontractor will locate and idntify utilities upon the ground surface and expose utility to determine size, depth and pipe material. The excavation will be conducted with a vactor to expose utility and minimize pavement restoration. A detailed spreadsheet will be provided by the subconsultant ' summarizing their subsurface utility explorations. Provide topographical survey along proposed piping alignment and proposed pump station site. The services will be completed by Hammond Collier and include the following: ■ Research and obtain background mapping, and recorded surveys. 0 Utilizing City orthographic aerial photographs and GIS data, Hammond Collier will coordinate with the City's project engineer for "Right -of -Entry", establishing logistics, determining a contact person, permission ' for project site entry, determination of property lines and rights -of -ways. 0 Determine and provide base line for utility locates. ■ Complete field survey to accomplish the topographic mapping within project limits. ■ Compile field data in preparation for AutoCAD and acquire utility record drawings. ■ Prepare base mapping. drawing scale will be 1" = 20' for half sizing to 1" = 40'. ■ Evaluate easement acquisition needs, if any, and report findings to the City. ' TASK LEAD: Russ Snow, P.E. — Senior Project Engineer, Hammond Collier Steve Wright, P.E. — Geotechnical Sub Consultant - Landau Assoc. Dave Enright — Utilities Locates — Applied Professional Engineering 1 HAMMOND COLLIER 2 WADE L.IVINGSTONE �� A. PROJECT APPROACH TASK NO.3 — FINAL DESIGN ENGINEERING A,RATIONALE: Hammond Collier proposes to use Flygt packaged submersib s�tin or " valent" be insta�eTto pump the sewage. We propose the Miltrorucs ti-Ranger series controller and pressure sensors along with redundant bulb type level sensors for high/low alarms and pump shut off. Hammond Collier will also use the services of Z Engineering to provide the necessary new electrical service, pump controls integration, emergency generator, and coordinate with power utility for location of power drop. Hammond ' Collier will also coordinate with the City of Renton's telemetry contractor to movide the necessary telemetry components and programming for monitoring status of e pump station. The alignment for the forcemain and gravity sewer replacement will be refined and final engineering provided. 1 1 ACTION OUTLINE: The scope of work for this project includes providing all necessary engineering, analysis, coordination, and documentation for the following: fo Research and determine appropriate pump and manufacture to meet system demands. Size forcemain and confirm alignment. Complete plan and profile of connection to sewer pressure main and connection to new gravity sewer collection improvements. Evaluate and propose alignment for gravity bypass of pump station. Size electrical service, motor controls, pump controls, and emergency power appurtenances. Coordinate and specify telemetry requirements in accordance with City of Renton standards. Conduct site visit with client staff to confirm available site for new package pump station. Coordinate with client design alignment of new gravity sewer bypass and confirm that conflicts do not exist with other pertinent underground utilities. Prepare plan view, site plan, sections for package pump station and details to support horizontal and vertical alignment design. Prepare site grading, access, fencing and restoration details for landscaping and paving as necessary. CO Prepare 60% plans and specifications for the proposed improvements and issue to City for review. Attend a design review meeting with City, and incorporate review comments and requirements. Prepare 95% plans, specifications, and cost estimates for the proposed improvements and submit for review. e Attend a design review meeting with the client and City, and incorporate review comments and requirements. ITASK LEAD: Russ Snow, P.E. — Senior Project Engineer, Hammond Collier I ' HAMMOND COLLIER WADE LIVINGSTONE A. PROJECT APPROACH TASK NO. 4 — PERMITTING & PROJECT APPROVAL RATIONALE: This work task will include preparing the appropriate permitting applications, variances and environmental documentations to obtain approvals to construct the proposed improvements. ACTION OUTLINE: Hammond Collier has extensive experience working with King County for permitting projects similar in scope to these proposed improvements. The work required to complete this task is as follows: CO Coordinate with King County and City to determine jurisdictional boundaries and regulatory authority. The city of Renton would be Lead Agency for SEPA process. CO Prepare SEPA Checklist and DNS for City of Renton processing and approval. CO Prepare right of way use and grading permit applications for King County. The grading permit will be needed for work outside County right of way possibly including the sewer bypass and pump station improvements. Evaluate the need for any sensitive areas variances and prepare appropriate application for County consideration. CO Schedule and attend pre -application meeting with King County. CO Submit completed applications and PS&E for County staff consideration and approvals. 0 Provide technical assistance during permit review and approval. ' TASK LEAD: Russ Snow, P.E. — Senior Project Engineer, Hammond Collier I TASK NO. 5 — BIDDING ASSISTANCE RATIONALE: Issue Final Construction Plans, Specifications, and Estimate for bidding purposes. ' Owner comments from the 95% submittal will be incorporated and final plans and specifications and cost estimate issued. This submittal will be in formats suitable for reproduction and distribution by the Owner. ACTION OUTLINE: Assistance during Bidding and Award willinclude attending a Pre -Bid meeting as required and the following: ' CO Contract Document Interpretations - Hammond Collier will provide respond to bidder inquiries and prepare addenda if necessary during the bid advertisement period. CO Prepare Contract Addendum — Hammond Collier will re are one addendum to address modifications and provide clarification of contract documents. 1 TASK LEAD: Russ Snow, P.E. — Senior Project Engineer, Hammond Collier ' TASK NO.6 —CONSTRUCTION MANAGEMENT RATIONALE: This task will provide the City of Renton with engineering support to insure the intent of the plans and specifications are interpreted correctly, materials and submittals meet specifications ' requirements., and the final completed project is consistent with the City's goals and expectations. IHAMMOND COLLIER 4 WADE LIv1NGSTONE �� 1 r A. PROJECT APPROACH ACTION OUTLINE: Hammond Collier's project manager will monitor construction progress and support City staff during contractor's construction activities. This work will consist of advising and consulting with the Owner during the Construction Phase Hammond Collier will provide the following services: CO Attend Preconstruction Conference per prime contractor for technical support on behalf of the Owner. CO Attend weekly construction Progress Meetings, (as needed), to provide technical interpretation of plans and specifications, address scheduling and construction related issues, and discuss any construction constraints. CO Conduct Project Manager site observations to review contractor progress, expedite construction by solving onsite problems, and document findings for compliance with intent of contract plans and specifications. Coordinate with geotechnical and electrical sub -consultants for input and site reviews as required. Review all materials and equipment submittals to ensure conformance with the plans and specifications. CO Prepare responses to contractor Requests for Information throughout construction activities. CO Assist in the negotiation of proposed change orders. CO Attend and verify Pump Station startup. Including review of start-up procedures and outcome. Technical review and approval of Operation and Maintenance Manual for new Pump Station. DO��' Upon completion of project, prepare a set of record drawings for the client based on the Contractor's and Inspector's observations and field measurements. One draft review set of plans will be submitted to the client for review and comment. After revisions are made, one set of final full-size mylar drawings and one electronic file of drawings will be provided. ' TASK LEAD: Russ Snow, P.E. — Senior Project Engineer, Hammond Collier TASK NO. 7 — PROJECT COORDINATION AND MANAGEMENT ' RATIONALE: Coordination with the City to ensure the engineering work is completed timely and within budget. Monthly statements of progress will be prepared summarizing the project status, fees ' invoiced, and remaining budget. ACTION OUTLINE: Quality assurance and quality control (QA/QC) will be provided as part of this ' subtask. Deliverables will be reviewed in-house to ensure quality and accuracy of the final deliverable. Formal project meetings will be held with the Owner to discuss deliverables and solicit review comments. %1 Project meetings will consist of a design development kickoff meeting, completion and submittal of 30% ' construction plans, 60% construction plans and submittal of 95% construction plans, specifications and engineer's estimate. In-house progress meetings will be conducted periodically through the design phase to insure coordination of sub -consultants, exchange of data, schedule and deliverable updates, and maintain communication with ' client. It is anticipated that a representative of the client would attend these progress meetings. TASK LEAD: Robin Nelson, P.E. — Senior Project Manager, Hammond Collier HAMMOND COLLIER 5 WADE LIVINGSTONE �� � M s=� M M= M M M M r M M M M r M A. PROJECT APPROACH 2. PRELIMINARY SCHEDULE 2006 2007 2008 DEC JAN FEB MAR APR MAN JLN JLL AL SEP OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV Consultant Selection Engineering Report Design Development OL Final Design Permitting / Project Approval Bid Assistance Construction Management Project Coordination HAMMOND COLLIER WADE LIVINGSTONE I A. PROJECT APPROACH 3. MAN HOURS ESTIMATE (By Task) CITY OF RENTON Summerwind/Stonegate Lift Station Consolidation and Field Avenue Interceptor 3 MANHOURS ESTIMATE PROJECT Sr_PROJECT PROJECT PROJECT SURVEYOR SR. CADO CACO MRO TASK MANAGER ENGINEER ENGINEER SURVEYOR TECH OPERATOR OPERATOR ROCESSING NO. TASK Robin Nelson Russ Snow Nic Schmidt Les Hilldebrand Bill Armstrong John Tilley Melissa Roe Hans Adomit HOURS 1 Engmering sport 23 32 92 0 0 0 16 32 -- 83 1.1 ServiceArea Determination 1 8 4 13 1.2 Lan Use 9uildable Lands Inventory 2 16 4 22 1.3 Establish Flow Rates 4 is 20 14 N7orkshop 12 8 B 28 1.5 Preliminary Sizing 4 Alt, 1B 16 1 24 1.6 Develop mg Estimates for 4 Ad. 0 241 32 1.7 Develop Decision Matrix B 4 4 16 1.0 Prepare Engineering Report 8 32 40 2 Design Development 10 28 40 40 48 8 60 0 234 2.1 Gectechn,cal rvaluation &Report (SubConsultant) 4 4 8 rmn a Utility Locates u consultant) q 4 6 21 n uct Field Vkrk for opo Survey 40 48 Be 24 Complete Base Mapping B 48 56 2.5 Preliminary 30% Design Plan & Profile 2 20 40 12 74 3 ma sign Engineering 4 124 256 0 0 14 108 70 576 3.1 Litt Station Plans, Specifications, and Details 40 60 2 24 24 150 3.2 Electrical & Controls Design (Sub consultant) 8 21 4 14 3.3 Gravity Sewer & Forcemain Final Design & Specifications 12 80 2 24 24 142 34 Prepare site grading, access, fencing, and restoration details 4 4 8 35 Conduct Site visit wide dient 4 41 0 36 Develop60%PS&E 2 16 32 6 24 121 92 3.7 Condua Desgn Review & Incorporate City review comments 8 16 24 3.8 Prepare 95%PS&E submttal 2 24 48 2 32 6 114 Conduct sign ewew ncorporate City review comments 18 16 24 4 Permitting & Project Approval 0 30 92 0 0 0 8 0 130 4.1 Prepare SEPA & DNS 2 201 22 4.2 Determine and Prepare V ng County Permit Applications 8 40 0 56 14 3 Attend Pre-Applicabon Meeting 4 4 44 Technical Assistance 16 32 48 S Bidding Assistance 0 36 64 0 0 0 0 0 100 5.1 Attend Pre -Bid Meeting 4 q 5.2 Respond to RFI'a 20 40 60 5.3 Prepagre Addendum 12 24 36 6 Construction Management 24 396 188 0 0 4 40 0 652 6.1 ttentl PraC.nstruct,on Conference 4 4 g [tend Construction Progress Meetings 128 48 1 1 1 176 Conduct Ste progress mondonng observations 128 128 4 Coorinaie with Sub-consultantsfor periodic observatmns 12 12 6.5 Review submittals 20 60 80 6.6 Respond to RFI's 40 40 80 6.7 Technical Assistance in processing change orders 201 40 60 6.0 Attend Project start up 8 8 wew and Apprwe Manual B 40 48 6.10 Complete Record Drawings 8 4 40 52 7 Project Coordination and Mgmt. 104 20 20 4 0 4 0 0 152 7 1 Prepare Project Plan 24 24 7.2 Q410C 60 60 71 In -House Design oor inati 20 20 20 4 4 66 A HOURS (LABOR CATEGORY 7Bee 752 44 4a 30 232 102 2039 IHAMMOND COLLIER 7 WADE LIVINGSTONE qP PROJECT MANAGEMENT m B. PROJECT MANAGEMENT 1 1. PROJECT MANAGEMENT APPROACH ' Hammond Collier believes in a "Strong Project Manager" system. The project manager will be the client contact and responsible for overall management including, coordination of labor and subconsultants, communication with the client and team members. Hammond Collier trains and requires their project 1 mangers to possess the following skills: Communications, conflict management, leadership, technical, project management, team management, "big City of Renton 1 picture" awareness, organization/time R E N T O N David Christensen management, and �,,,...,,, ,,,. ,,,,, ,., k�., Wastewater Utility political sensitivity. A project manger has the authority to negotiate project 1 fee's, scopes and supplement Robin Nelson, P.E. the project team to ensure Project Manager / Client Contact Pete Weber, P.E. project schedules are met. QA/QC Principal in Chargc Quality Assurance and Quality 4� �� Control are essential responsibilities HAMMOND COLLIER IIAMMON U COLLIER of the project manager. Hammond WADE UV I NGSTONE WADE LIV I NGSTONE Collier implements a QA/QC program that begins at the ' project scoping and continues GEOTECHNICAL WASTEWATER ENGINEERING through project closeout. ENGINEERING The Project Manager Russ Snow, P.E. develops a QA/QC review Steve Wright, P.E. Senior Wastewater Engineer / schedule in the project plan Geotechnical Construction Manager and reviews all deliverables Investigations during production so that Nic Schmidt, E.I.T. we comply with company Engineering Support standards and meet client LANDAU Construction Support 14 expectations. Our strategy ASSOCIATES ' is simple; to require that Robert "Les" Hillebrand, P.L.S. project mangers maximize ELECTRICAL Survey Manager client satisfaction and the ENGINEERING ' quality of the project design. At the start of every project, Brian Zeismer, P.E. HAM O N ll L (� L L l E R ' Hammond Collier initiates Electrical /Telemetry / WAD E LIVINC STONE and updates our QA/QC Controls responsibility matrix that z_Engineering documents all QA/QC review steps. This matrix becomes part of the 2. ORGANIZATIONAL CHART IN permanent file record; auditable and available for Utility Locates our clients review. ' HAMMOND COLLIER 8 WADE LIVINGSTONE �� PROJECT TEAM MEMBERS = m m m m = = m w== m m m m m m= m C. PROJECT TEAM MEMBERS 1. ROLE & EXPERTISE PETER J. WEBER, P.E. — PRINCIPAL IN CHARGE Mr. Weber is the Director of Hammond Collier's Water Resources Department and has over thirty years of project management experience and funding expertise. Over the years, Mr. Weber has served as Project ' Manager for transportation, stormwater planning/drainage, and wastewater development projects. Other responsibilities include developing design standards, contract supervision, agency coordination, construction/bid preparation, planning/plan check reviews, permitting, bidding, and due diligence reporting. ' Most recently, Mr. Weber was a team member who managed the PS&E components and provided CM services for the City of Marysville's Effluent Transfer Pipeline project. ROBIN D. NELSON, P.E. — PROJECT MANAGER / CLIENT CONTACT Mr. Nelson has over 20 years of municipal engineering experience serving counties, cities, and special purpose districts. His experience spans both the private and public sector service in the areas of wastewater quality, stormwater management, LID and ULID proceedings, PS&E preparation, parks and recreation, civil site 1 development, and transportation. Mr. Nelson has served as a senior project manager for a variety of complex projects including comprehensive wastewater system plans, capital facilities plans, engineering reports, water and sewer utility PS&E, parks and recreation PS&E, stormwater management planning, and rate analysis. He possesses a thorough understanding of infrastructure funding requirements and success in assisting communities meet their funding needs. Mr. Nelson is well known for his communication skills, innovative design, and successful project management. ' RUSSELL W. SNOW II, P.E. — SENIOR WASTEWATER ENGINEER Mr. Snow has 30 years of experience developing and implementing municipal civil engineering designs for utilities, pumping stations, roadways, site improvements, and facility infrastructure upgrades. Prior to joining Hammond Collier, Mr. Snow was Senior Engineer/Project Manager for eight years with Fujiki & Associates, which Hammond Collier acquisitioned in 1998. Mr. Snow has served in the role of Senior Engineer for many ' public sector clients and projects, including King County Metro, Seattle Public Utilities, City of Bellevue Utilities Department, City of Marysville, Olympus Terrace Sewer District, Soos Creek Water and Sewer District, Woodinville Water District, and Water District No. 54 in Des Moines, Washington. ' NIC R. SCHMIDT, E.I.T. — PROJECT ENGINEER I Mr. Schmidt has four years engineering experience assisting engineers with PS&E, Comprehensive and Capital Facilities Planning, Developer Plan Reviews, Cost Estimating, and Construction Observation. Mr. Schmidt's project experience focuses on civil engineering encompassing water, sewer, and storm water utilities. Mr. Schmidt also has experience with topographical surveys using Topcon TDS Data Collectors. ' ROBERT L. HILLEBRAND, P.L.S. — SURVEY MANAGER Mr. Hillebrand has 25 years of survey experience and is responsible for overseeing all aspects of our survey department including survey crews, fieldwork, and work products. He has extensive experience in both ' engineering surveying and land surveying. These areas include: Topographic Surveys, ALTA surveys, Boundary surveys, Construction Coordination, and Route Surveys. STEVE WRIGHT, P.E. — SENIOR GEOTECHNICAL ENGINEER Steve has 18 years of experience conducting geotechnical investigations and providing construction monitoring services throughout the Pacific Northwest for a variety of structure and infrastructure projects, including projects for King County, Seattle Public Utilities, and Auburn. Steve has also worked on many sewer rehabilitation/extension, creek and habitat improvement, culvert and drainage improvement, and landslide stabilization projects for municipalities in western Washington. IHAMMOND COLLIER 9 WADE LIVINGSTONE �� I I C. PROJECT TEAM MEMBERS 2. RELEVANT EXPERIENCE KERSEY 3 SEWER LIFT STATION Auburn, Washington Hammond Collier was selected to prepare an Engineering Report to evaluate the need for a pump station to serve a proposed new development. The Engineering Report resulted in the development of 3 alternatives to serve the properties. Alternatives included 1 high head (365 ft) lift station, a 2 lift station scenario, and a gravity system. Hammond Collier recommended the 2 lift station scenario because it worked well with the phasing of the developments and also would expedite construction. KERSEY THREE/SANTARY SEWER LIFT STATION AUBURN, WASHINGTON sar , �e.our ec.oVan,a oaea .eo ..,.. ,� sm � yr aura anrs .at , es+or'ara asr,s s.r -� ssescr yr .na t• ,vr ear w sensor rw - ius au . ar sus sm n sscarr asos +.sr Mr! �OIt 1iW at HAmmoND COLLIER / N W— Lrvwcarvaw Client Contact: Tom Young Hammond Collier was also 22430 Southeast 231" responsible for coordinating Maple Valley, WA 98038 structural, electrical, and telemetry 425-392-5722 subconsultants as well as developing contract plans, specifications, and Project Cost: $500 Thousand construction cost estimate for the Project Year: 2006 - 2007 design of the new sanitary sewer lift stations. HAMMOND COLLIER 611>1 10 WADE LIVINGSTONE qP I I I 1 C. PROJECT TEAM MEMBERS PUMP STATION REHABILITATION DESIGN City of Entiat, Washington The City of Entiat selected Hammond Collier to evaluate 4 of their existing wastewater pump stations for necessary upgrades and improvements. In addition, Hammond Collier evaluated siting considerations for a proposed new future pump station along the Entiat River. Hammond Collier's evaluation of the 4 existing wastewater pump stations included documenting the existing facilities from conducting site visits, reviewing as -built records, developing estimates of projected wastewater flows, evaluating alternatives, and developing recommendations for upgrades and cost estimates for each pump station. Hammond Collier prepared an Engineering Report that summarized our findings, recommendations, and conclusions to rehabilitate the pump stations, which was approved and adopted by the City. Hammond Collier and our subconsultants then ' proceeded with design plans and specifications, which entailed major modifications to the mechanical, electrical, and telementry facilities at 1 3 of the 4 pump stations. This included new submersible duplex pumps, piping, valves and valve vault, forcemain drain, hatches, and over 2,300 lineal feet of new off -site forcemain and gravity sewer pipelines. Client Contact: ' Bob Whitehall Public Works Superintendent ' 14070 Kinzel Street Entiat, WA 98822 509-784-1500 Project Year: 2006 - 2007 Project Cost: $1.2 Million Pre -design evaluations determined that abandonment and removal of the 4th pump station from service was possible and therefore a design was developed whereby it was replaced with over 1,700 lineal feet of new gravity sewer. In addition, new site improvements were designed at each site including improved security, paved surfaces, washdown facilities and ventilation. HAMMOND COLLIER 1 I WADE LIVINGSTONE qP I 1 1 C. PROJECT TEAM MEMBERS TRANSFER PIPELINE To EvERETT City of Marysville, Washington Hammond Collier was a team member on the Effluent Transfer Pipeline Project for the City of Marysville. This $49 million dollar project includes treatment plant upgrades, a new effluent pump station, and a 36-inch diameter day effluent transfer pipeline that has an 18-million gallons per day capacity. The 23,000-foot route of the pipeline traverses three significant tidal water crossings and 4 miles of narrow public streets whose traffic cannot be rerouted, and also adjoins continuous wetlands. Hammond Collier was responsible for PS&E development for the pump station and effluent transfer pipeline. Effluent Pump Station replaced three existing 3,000 gpm vertical turbine pumps with four 4,700 gpm vertical turbine pumps. The total dynamic head capacity of the pump station was increased from 15 feet to 104 feet in order to accommodate the future effluent transfer pipeline. We also replaced the discharge piping in order to accommodate increased flows, the added flow diversion vaults to vary effluent discharge points, and made provisions for bypass pumping during construction. Client Contact: Jeff Massie, P.E., Asst. City Engineer 80 Columbia Avenue Marysville, WA 98270 360-651-5500 M k ' Project Information: Project Year: 2005 Pre -Bid Estimate $5.3 Million Low Bid Price $3.6 Million Final Construction Amount $3.6 Million HAMMOND COLLIER 1 Z WADE LIVINGSTONE Q P C. PROJECT TEAM MEMBERS TRUNK D EXTENSION — PHASE I, INCLUDING SUNNYSIDE LIFT STATION City of Magst7lle, Washington Hammond Collier was responsible for developing contract plans, specifications, and construction cost estimate as well as coordinating structural, electrical, and telemetry subconsultants in the design of a 4.0 million gallons per day sanitary sewer lift station. Client Contact: David Zull, P.E. 80 Columbia Avenue Marysville, WA 98270 360-651-5100 Project Cost: $1.7 Million Project Year: 2000 Project included a flooded suction wet-well/dry-well configuration with three immersible screw pumps and appurtenances, above grade control building, on -site emergency generator, below grade wet -well blower and flow meter vault structures, landscaping and other site improvements. Phase I also included design and construction management services of 5,500 lineal feet of 24-inch diameter sanitary sewer interceptor along street right-of-way, undeveloped properties, boring under wetlands and other sensitive areas. The project involved acquisition of local, state and federal permits, selection of materials, appraisal and acquisition of utility easements, preparation of environmental studies, hydraulic analysis, route analysis, survey of sensitive areas, and design. IHAMMOND COLLIER 13 WADE LIVINGSTONE Q0 C. PROJECT TEAM MEMBERS 3. SUBCONSULTANTS LANDAU City -Wide Sewer System — Natural Resource Inventory; Carnation, WA. As part of the vacuum conveyance sewer system project in Carnation, 14' ASSOCIATES Landau Associates completed an inventory of critical environmental areas within city limits along and in the vicinity of the proposed system alignment and vacuum stations. Biologists conducted a reconnaissance -level study to identify wetlands, streams, rivers, and ' critical wildlife habitat using aerial photographic interpretation, review of existing public domain resources, and field verification. Overlays on aerial photographs showing the presence of wetland, river, and wildlife habitat were produced as part of the report documenting existing conditions, wetland and stream classifications and buffers, and ' the potential regulatory implications for development in and adjacent to these areas, including a discussion of Shoreline Management permits. This information was used to refine the proposed alignment for the new city-wide sewer system and to prepare environmental permit applications. North Creek Interceptor Project; Bothell, WA. Landau Associates is providing environmental and geotechnical engineering services for a new sewer interceptor for the Alderwood Water and Wastewater District. The project ' will consist of approximately 9000 feet of 48-inch sewer pipe and will extend from near the intersection of 196Th Street and SR 527 in Snohomish County to 228th Street in Bothell, roughly following the North Creek drainage. The project scope includes assessment of three alternatives, all of which include multiple stream and highway crossings. Construction techniques that will be considered include trenching with shored excavations and trenchless technologies. A phase one site assessment of the project corridor has been completed and has identified a number of sites of potential contamination. A phase two assessment will be completed upon determination of the preferred alignment ' Percival Pump Station; Olympia, WA. Landau Associates is providing environmental documentation and geotechnical engineering services to Kennedy/Jenks and the City of Olympia to support a route study and ' predesign of a proposed new pump station and potable water transmission pipeline and water re -use pipeline in the Capital Lake area of Olympia, Washington. The pump station is proposed for a vacant lot across from Marathon Park. The location of the pump station on the lot has not been determined. The pump station may be constructed either at grade or below grade. The new potable water pipeline is anticipated to have a diameter of between 12 and 16 inches and be constructed of restrained joint ductile iron pipe or butt fusion welded HDPE. The water re -use pipe is anticipated to be constructed out of 4-inch butt fusion HDPE pipe. Three corridors are being considered ' for the new pipeline. Environmental documentation includes addressing permitting issues (NEPA, SEPA, BA, etc.) and wetland delineation. Geotechnical issues being addressed include seismic vulnerability, open trenching, trenchless construction, construction on and adjacent to steep slopes, and high groundwater. ' Z-ENGINEERS, PLLC is an Electrical and Control Systems engineering consulting firm specializing in water and waste water systems. The staff of Z Engineers has extensive experience in the design of ' both new and upgrades to existing waste water and lift station pumping stations. This includes design of electrical, control, and SCADA systems from the concept phase through design, construction, programming, commissioning, and ongoing support.' ' Applied Professional Services is equipped to handle your utility locating, subsurface utility exploration (SUE) and video pipe inspection needs. APS is building and refining partnerships with civil/consulting engineers, design firms, surveyors, municipal state and federal agencies, contractors and geotech/environmental firms. We strive to provide you Serwices, Incorporated with cost effective, accurate results to facilitate rapid decision making and project realization. HAMMOND COLLIER 14 WADE LIVINGSTONE �� REFERENCES& INSURANCE m m m m m i == m i m m = = m D. REFERENCES / E. INSURANCE 1. SEWER LIFT STATION REFERENCES City of Marysville David Zull, P.E. 80 Columbia Avenue Marysville, WA 98270 360-363-8100 Olympus Terrace Sewer District ' Patrick Sorensen, District Manager 4902 76" Street SW Mukilteo, WA 98275 425-353-6000 1 1 2. PROJECT MANAGER REFERENCES City of Kirkland ' Denise Pirolo, Project Manager 123 Fifth Avenue Kirkland, WA 98033-6189 ' 425-803-1912 City of Yakima Dave Zabell, Asst. City Manager ' 129 N. Second St. Yakima, WA 98901 509-575-6040 Kersey 3 Development Tom Young 22430 Southeast 231s` Maple Valley, WA 98038 425-392-5722 City of Entiat Bob Whitehall Public Works Superintendent 14070 Kinzel Street Entiat, WA 98822 509-784-1500 City of Marysville Jeff Massie, P.E., Asst. City Engineer 80 Columbia Avenue Marysville, WA 98270 360-651-5500 Mason County Utilities & Waste Management Tom Moore, Deputy Director PO Box 1850 Shelton, WA 98584 360-427-9670 ex. 652 E1. INSURANCE COVERAGE Hammond Collier has the ability to meet the City of Renton's insurance coverage requirements. Our professional liability insurance coverage is for $1,000,000 per claim. HAMMOND COLLIER �� 15 WADE LIVINGSTONE