Loading...
HomeMy WebLinkAboutWWP273712 (8)�� Insituform an A E G 10 Kom pany Road Construction Northwest, Inc. City of Renton, WA Contract# CAG-15-118 Reline/Upsize Project No. 202233 Pre & Post CCTV Inspection Reports Media 01 (&)/nsituform- video Table of Contents AnAegivn'Cotnpany Project Number 202233 Road Construction Northwest, Inc. - City of Renton, WA Video Package 1 Manhole Inspect Type Up Stream Down Stream Diameter Length Pipe / Material Type PRE 1968 1968A 24.000 172 VCP POST 1968 1968A 24.000 172 CIPP PRE 1968A 1967 24.000 282 VCP POST 1968A 1967 24.000 282 CIPP PRE 1967 2019 24.000 205 VCP POST 1967 2019 24.000 205 CIPP Segments Install Length Description Media Totals 3 659 Media Number 01 Package Totals 3 659 Package 1 Media Number 01 Surveyors name Certificate Number S rstem Owner Survev Customer Drainage Area Sheet A. Clary U-613-47562 I City of Renton. WA I Road Const. Northwest Inc. I I 1 1 P/O No. Pipeline Segment Reference Date Time Location Street Name and number Localit 202233 001-001 20160824 09054th Ave I I Renton WA Further Location details Upstream Manhole Number Rim to Invert Grade to Invert Rim to Grade 1968� Downstream Manhole Number Rim to Invert Grade to Invert Rim to Grade Use of Sewer —— Direction Flow Control Hei ht 1968A � � II Sanitary U pstream I—� 24 Width Sha a Material Ln. Method PiDe Joint Len th Total Len th Length Surve ed Year Laid Year Rehabilitated 0 Circular VCP 172 170.1 0 Ta e / Media Number 01 Purpose Sewer Cate o Pre-Cleaninq Cleaned Weather Additional Information D Jettin-1 1 D Distance (Feet) Code. Continuous , defect Value Joint Circumferential Location Image Ref. 'Grade Struct: O&M 'Grade' . Remarks_ Group/ Descriptor Modifier/ severityS/M/L' Inches o /o At-/ From To 1st 2nd 0.0 AMH Starting Manhole: 1968A 0.0 MWL 0 170.1 AMH 1968 Structural 0.& M Overall r N M �' L r N (n V In r N M V u7 C� y 'C 'C 'O M '� E U K 13 'O 'O 'O = -Y X f4 L fSf L f9 L RS L f6 L �+ (a •513L L L L L (a •� -a L V ` L `� Segment 00 0 0C9 W CI c 0 C7 C7 C9 0 W CJ r C7 C9 C9 C9 C7 Q: Ci = 202233 001-001 1968 1968A Pre -Rehabilitation 0 0 0 0 0 0 0000 0 0 0 D 0 0 0000 0 0 0 0 0 0 0000 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. (6) Insituform Upstream MH: 1968 Surveyor's Name: A. Clary System Owner: City of Renton, WA Drainage Area: City: Renton, WA Pipe Segment Ref.: 001-001 Sewer Use: Sanitary Flow Control: Material: Vitrified Clay Pipe Media Number: 01 W r Pre -Cleaning: Jetting Date: 20160824 Time: 09.05 Cleaned: Year Laid: Year Rehab.: Additional Information: �tg. Code Description 0.0 AMH Access Point- Manhole 0.0 MWL Water Level 170.1 AMH Access Point - Manhole Downstream MH: 1968A Certificate Number: U-613-47562 Survey Customer: Road Const. Northwest, Inc. Purchase Order #: 202233 Street Address: 4th Ave Location Details: Direction: Upstream Shape: Circular Ln. Method: Purpose: Pre -Rehabilitation S u rvey Weather: Dry Height: 24 Measurements: U/D Width: Rim to Invert: / Joint Length: Grade to Invert: / Total Length: 172 Rim to Grade: / Len. Surveyed: 170.1 Sewer Category: Position Comment Starting Manhole: 1968A 1968 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. Surveyors name Certificate Number System Owner Survey Customer Drainage Area Sheet A. Clary U-613-47562 I F—City of Renton WA Road Const. Northwest Inc I I I 1 P/O No. Pi eline Segment Reference Date Time Location Street Name and number Locality 202233 r001-001 20160824 20:51 N 4th St Renton WA Further Location details Upstream Manhole Number Rim to Invert Grade to Invert Rim to Grade 1968 _l Downstream Manhole Number Rim to Invert Grade to Invert Rim to Grade Use of Sewer Direction Flow Control Height 1968A I I I I I I I Sanita Upstream 1 24 Width Sha a Circular Material Ln. Method Pipe Joint Len th Total Length Len th Surve ed Year Laid Year Rehabilitated VCP CP j 1 1172 168.2__1 0 2016 Tape / Media Number 01 Purpose Sewer Category Pre -Cleaning C No Pre- Cleaning Cleaned Weather Additional Information Dry Code Value Circumferential .Distance Continuous Joint Location - Image Ref. Struct. O&M. :Group/ . Modifier/ - Inches At,/ (Feet) defect Grade .Grade De"scri tor. . _ . P severit _ -y S/M/L' U /o - From To Remarks 1,st.:;._2nd 0.0 AMH Starting Manhole: 1968A 0.0 MWL 0 168.2 AMH 1968 .Structural'. o& M. :Overall" r N M le N N M It Ln r- N M le Ln . d LU d d d Y y Lv -a N -a d d -a Y �_ a d -a a d a X X L-°o L Leo L L Lea L L-°a L La _� •� L _ L LLS L L _ L LC L. L _ L fa -O L L i i cc �_ 'C3 Segment 0 0 0 0 0 U C9 C9 C� C9 C9 Ci C7 CO C9 C9 CO W Ci E 202233 001-001 1968 1968A Post Rehabilitation 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. (9) ,Insituforrri Upstream MH: 1968 Surveyor's Name: A. Clary System Owner: City of Renton, WA Drainage Area: City: Renton, WA Pipe Segment Ref.: 001-001 Sewer Use: Sanitary Flow Control: Material: Vitrified Clay Pipe Media Number: 01 0 I v Pre -Cleaning: No Pre -Cleaning Date: 20160824 Time: 20:51 Cleaned: Year Laid: Year Rehab.: 2016 Additional Information: -tg. Loae uescription 0.0 AMH Access Point- Manhole 0.0 MWL Water Level 8.2 AMH Access Point - Manhole Downstream MH: 1968A Certificate Number: U-613-47562 Survey Customer: Road Const. Northwest, Inc. Purchase Order #: 202233 Street Address: N 4th St Location Details: Direction: Upstream Shape: Circular Ln. Method: Cured in Place Purpose: Post Rehabilitation Survey Weather: Dry Height:24 Measurements: U/D Width: Rim to Invert: / Joint Length: Grade to Invert: / Total Length: 172 Rim to Grade: / Len. Surveyed: 168.2 Sewer Category: Position Comment Starting Manhole: 1968A 1968 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. Nqs o Surveyors name Certificate Number System Owner Survey Customer Draina a Area Sheet A. Clary U-613-47562 P/O No. Pipeline Segment Reference 202233 001-002 —� Cif of Renton WA Date Time 120160824 ___1 F0824 Road Const. Northwest Inc. Location Street Name and number Localit 4th Ave Renton WA I I -� Further Location details Upstream Manhole Number Rim to Invert Grade to Invert Rim to Grade 1968A Downstream Manhole Number Rim to Invert Grade to Invert Rim to Grade Use of Sewer Direction Flow Control Hei ht 1967 Downstream 24 Width Sha a Material Ln. Method Pine Joint Len th Total Len th Len th Surve ed Year Laid Year Rehabilitated 0 Circular VCP 0 282 282 1 Tape / Media Number 101 Purpose Sewer Category Pre-Cleanin Cleaned Weather Additional Information D JettinI I I Dry -Distance (Feet) Code continuous defect Value Joint Circumferential Location Image Ref. Sttuct. Grade' O&M Grade Group/ Modifier/ Inches- At / Descriptor severity S/M/L 1 st' .. •. 2nd o �o From To Remarks 0.0 AMH Starting Manhole: 1967 0.0 MWL 0 21.1 TF C 6 9 23.7 TF C 6 3 172.0 TF 6 3 255.4 TF 6 1 282.0 AMH 1968A Structural O & M Overall r N M It to r N M I L r CM 11 to d (D a)d CDy X d d d d Y �_ d a N a N a d Y x (Q •� � co L m L tC L N L co L + (tf � axi � as L M L to L m L to L (Q •� m �C Segment CD CD C7 0 CD W O E (D CD CD c9 (D W Cl 5 c9 C7 tD c9 C9 U C'1 202233 001-002 1968A 1967 Pre -Rehabilitation 0 0 0 0 D 0 0000 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech@ TV inspection system. (6) lnsituform Upstream MH: 1968A Surveyor's Name: A. Clary System Owner: City of Renton, WA Drainage Area: City: Renton, WA Pipe Segment Ref.: 001-002 Sewer Use: Sanitary Flow Control: Material: Vitrified Clay Pipe Media Number: 01 Pre -Cleaning: Jetting Date: 20160824 Time: 08:24 Cleaned: Year Laid: Year Rehab.: Additional Information: �tg. Code Description 0.0 AMH Access Point- Manhole 0.0 MWL Water Level 1.1 TFC Tap, Factory Made: Capped 3.7 TFC Tap, Factory Made: Capped 2.0 TF Tap, Factory Made 5.4 TF Tap, Factory Made 2.0 AMH Access Point- Manhole Downstream MH: 1967 Certificate Number: U-613-47562 Survey Customer: Road Const. Northwest, Inc. Purchase Order #: 202233 Street Address: 4th Ave Location Details: Direction: Downstream Shape: Circular Ln. Method: Purpose: Pre -Rehabilitation Survey Weather: Dry Height:24 Measurements: U/D Width: Rim to Invert: / Joint Length: Grade to Invert: / Total Length: 282 Rim to Grade: / Len. Surveyed: 282 Sewer Category: Position Comment Starting Manhole: 1967 9 3 3 i 1968A Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech@) TV inspection system. Ngs�o Surveyors name Certificate Number System Owner Surve Customer Drainage Area Sheet A. ClaryU-613-47562 Cityof Renton WA Road COnst. Northwest Inc.-� P/O No. Pipeline Segment Reference Date Time Location Street Name and number Localitv 202233 001-002 20160824 17:55 N 4th St Renton WA Further Location details Upstream Manhole Number Rim to Invert Grade to Invert Rim to Grade 1968A I I I I - I Downstream Manhole Number Rim to Invert Grade to Invert Rim to Grade Use of Sewer Direction Flow Control Hei ht 1967 1 1-�1 1 1 1 Sanitary Upstream D 24 Width Sha a Material Ln. Method Pipe Joint Length Total Len th Length Surve red Year Laid Year Rehabilitated Tape / Media Number 0 Circular VCP CID282 281.1 2016 01 Pur ose Sewer Category Pre-Cleaninq Cleaned Weather Additional Information C No Pre- I = I Dry Cleaning Code. Value Circumferential Distance. Continuous Location Struct '08tM (Feet) detect Joint ;Ima a Ref: g Grade Grade Group/ Modifier/ Inches At/, 'Descriptor severity S/M/L o ✓o From . To. Remarks 1st 2nd 0.0 AMH Starting Manhole: 1967 0.0 MWL 0 170.0 TB A 6 2 Open 253.6 TB A 6 2 Open 281.1 AMH 1968A Structural O & M Overall r N M tt to r N M Cr to r N M et to d d N d d C Y V x y N "C tU 'C N 'd d N M Y U_ x N 'C d 'O d 'C 0 'a d 'O Y x t4 L fS3 L fC L fC+ L L (Q •� f4 L 1 M L M L M L M L w (a t4 L M L M L W L N L ++ f6 V •� N -C Segment C7 C9 C9 C9 0 W Cy c C9 C9 C9 C9 C9 W Cy C7 C9 C9 C9 C9 W Cy E 202233 001-002 1968A 1967 Post Rehabilitation 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. (6) lnsituform Upstream MH: 1968A Downstream MH: 1967 Surveyor's Name: A. Clary Certificate Number: U-613-47562 System Owner: City of Renton, WA Survey Customer: Road Const. Northwest, Inc. Drainage Area: Purchase Order #: 202233 City: Renton, WA Street Address: N 4th St Pipe Segment Ref.: 001-002 Location Details: Sewer Use: Sanitary Direction: Upstream Flow Control: De -Watered using Jetter Shape: Circular Material: Vitrified Clay Pipe Ln. Method: Cured in Place Media Number: 01 Purpose: Post Rehabilitation u Pre -Cleaning: No Pre -Cleaning Date: 20160824 Time: 17:55 Cleaned: Year Laid: Year Rehab.: 2016 Additional Information: Ctg. Code Description 0.0 AMH Access Point- Manhole 0.0 MWL Water Level '0.0 TBA Tap, Break-in / Hammer: Active 3.6 TBA Tap, Break-in / Hammer: Active 1.1 AMH Access Point- Manhole Su rvey Weather: Dry Height:24 Measurements: U/D Width: Rim to Invert: / Joint Length: Grade to Invert: / Total Length: 282 Rim to Grade: / Len. Surveyed: 281.1 Sewer Category: Position Comment Starting Manhole: 1967 2 Open 2 Open 1968A Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. NAsI Surveyors name Certificate Number System Owner ­1 Survey Customer Drainage Area Sheet A. Cla U-613-47562 FCitv of Renton WA Road Const. Northwest. Inc. ---1 1 P/O No. Pipeline Segment Reference Date Time Location Street Name and number Locali 202233 001-003 20160824 07:52 4th Ave — Renton WA Further Location details U stream Manhole Number Rim t�nvert Grade to Invert Rim to Grade Street 1967 Downstream Manhole Number Rim to Invert Grade to Invert Rim to Grade Use of Sewer Direction Flow Control Height 2019 1 1 7 1 1 1 1 Sanitary24 ] Upstream Width Sha a Material Ln. Method Pipe Joint Len th Total Length Length Surveyed Year Laid Year Rehabilitated 0 CircularI VCP 0 1 1 1205 1 1201.7 Tape / Media Number 01 Purpose Sewer Cateciory Pre-Cleaninq Cleaned Weather Additional Information D I I Jetting 1 1 Dry 1 'Distance (Feet) ". ,Code _ 'Continuous,, derecr Value Joint Circumferential Location Image'Ref• Struct.' Grade O&M Grade.: Group/, Modifier/ Inches At/ 'Descriptor - - severity _; S/M/,,L,. 1'st 2nd From, To Remarks 0.0 AMH Starting Manhole: 2019 0.0 MWL 0 201.7 AMH 1967 Structural: 0 ;& M '. Overa9l N M Ct Ln c- N M LO r- N M It Ln AC V x O 13 'O C O C U_ x C 'O 'C 'C C X x IC fC1 f6 RS ++ Ifi 7 -O L L L L L �+ IC fa L fC L R1 L fC L fC as ++ (tj S d C Segment C9 C9 0 0 0 tY Cl c C9 0 0 0 C9 W Cy 0 0 C9 CO 0 W CI '_ 202233 001-003 1967 2019 Pre -Rehabilitation S 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. (9) ►nsitufarni Upstream MH: 1967 Surveyor's Name: A. Clary System Owner: City of Renton, WA Drainage Area: City: Renton, WA Pipe Segment Ref.: 001-003 Sewer Use: Sanitary Flow Control: Material: Vitrified Clay Pipe Media Number: 01 v� I Pre -Cleaning: Jetting Date: 20160824 Time: 07:52 Cleaned: Year Laid: Year Rehab.: Additional Information: �Lg. Code Description 0.0 AMH Access Point- Manhole 0.0 MWL Water Level 1.7 AMH Access Point- Manhole Downstream MH: 2019 Certificate Number: U-613-47562 Survey Customer: Road Const. Northwest, Inc. Purchase Order #: 202233 Street Address: 4th Ave Location Details: Street Direction: Upstream Shape: Circular Ln. Method: Purpose: Pre -Rehabilitation Survey Weather: Dry Height:24 Measurements: U/D Width: Rim to Invert: / Joint Length: Grade to Invert: / Total Length: 205 Rim to Grade: / Len. Surveyed: 201.7 Sewer Category: Position Comment Starting Manhole: 2019 1967 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. Surveyors name Certificate Number System Owner Survey Customer Drainage Area Sheet A. Clary U-613-47562 City of Renton [Road ad Const. Northwest Inc. 1 P/O No. Pipeline Se ment Reference Date Time Location (Street Name and number) Localit 202233 001-003 1 120160824 20:57 N 4th St —� Renton WA Further Location details Upstream Manhole Number Rim t� o Invert GGr de to Invert Rim to Grade 1967 Downstream Manhole Number Rim to Invert Grade to Invert _ Rim to Grade Use of Sewer Direction Flow Control He'clht 2019--— Sanitary Downstream 24 Width Sha a 0 CircularI Material Ln. Method Pipe Joint Len th Total Len_q th Len th Surve ed Year Laid Year Rehabilitated VCP CID I 1 1205 197.9 1 2016 1 Tape / Media Number 11 Pur ose Sewer Category Pre-Cleanin_q C No Pre- Cleaning Cleaned Weather Additional Information I I I Dry -Distance (Feet) Code Continuous detect Value joint I Circumferential Location. Image Ref: 9 Struct. Grade. O&M Grade _ - Remarks. Group/ -Descriptor -.. Modifier/ severity S/M/L Inches a ' 7o At /, From To - 1 st .. .2nd. ', 0.0 AMH Starting Manhole: 1967 0.0 MWL 0 197.9 AMH 2O19 Structural O &..M. Overall .r. N M et to T" N M It LO r- N M et LA d d d Y x d a N a N o d v e = Y x d a d a d a d a = Y x M ca M L M a Segment 0 0 0 0 0 W a E (9 (7 (9 (9 (9 W Cy 0 0 0 0 0 W a E 202233 001-003 1967 2019 Post Rehabilitation S 0 0 0 0 0 0 0000 0 0 0 0 0 0 0000 0 0 0 0 0 0 0 000 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system. (6) ►ns tufar,n Upstream MH: 1967 Surveyor's Name: A. Clary System Owner: City of Renton, WA Drainage Area: City: Renton, WA Pipe Segment Ref.: 001-003 Sewer Use: Sanitary Flow Control: Material: Vitrified Clay Pipe Media Number: 01 lap v 1 Pre -Cleaning: No Pre -Cleaning Date: 20160824 Time: 20:57 Cleaned: Year Laid: Year Rehab.: 2016 Additional Information: Ctg. Code Description 0.0 AMH Access Point- Manhole 0.0 MWL Water Level 7.9 AMH Access Point- Manhole Downstream MH: 2019 Certificate Number: U-613-47562 Survey Customer: Road Const. Northwest, Inc. Purchase Order #: 202233 Street Address: N 4th St Location Details: Direction: Downstream Shape: Circular Ln. Method: Cured in Place Purpose: Post Rehabilitation Survey Weather: Dry Height:24 Measurements: U/D Width: Rim to Invert: / Joint Length: Grade to Invert: / Total Length: 205 Rim to Grade: / Len. Surveyed: 197.9 Sewer Category: Position Comment Starting Manhole: 1967 2019 Generated on Thursday, 9/8/2016 at 08:51 AM by the PipeTech® TV inspection system.