Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P_Sprinkler_Drawings_Stor-House_181116_V1
ABOVE FINISHED FLOORBOTTOM OF TRUSSBOTTOM OF PURLINBOTTOM OF JOISTBOTTOM OF DECKBOTTOM OF BEAMINSIDE FACE OF WALLUNLESS NOTED OTHERWISENO AUTO. SPRINKLERSOUTSIDE FACE OF WALLABBREVIATIONSBOPCTSBOTOFOWNASIFOWUNOFOCUT TO SUITFIELD ORDERAFFBODBOJBOBHYDRAULIC CALCULATION NODEFLEXIBLE COUPLINGRIGID COUPLINGELEVATION ABOVE REFERENCED2-WAY EARTHQUAKE SWAY BRACE4-WAY EARTHQUAKE SWAY BRACECENTERLINE OF PIPE TO REFERENCEDLETTER INDICATES TYPELETTER INDICATES TYPESTRUCTURE IN INCHESHANGER LOCATIONPOINT IN FEET AND INCHESAABOD12SYMBOL LEGENDREVISIONSREASON FOR REVISIONNO.BYDATEKEY PLANHANGER LEGENDSYMMANUFACTURERS.I.N.TYPEMODELSPRINKLERFINISHESCUTCHEONFINISHORIFICESIZETHREADSIZETEMP.RATINGQUANTITYSPRINKLER LEGENDTOTAL THIS SHEETOFFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.OFPROJECT MGRFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.PROJECT MGRTC18111THE STOR-HOUSEPHASE IV2829 NE 3RD STREETRENTON, WA 9805616M. MILLER11-16-18S. LAVINCONTRACT WITHPROJECT MANAGER :PHONE :FAX :SUPERINTENDENT :PHONE :FAX :COLVOS CONSTRUCTION711 COURT CTACOMA, WA 98402BRIAN NEAL253-844-4640JEFF BIRD253-355-2088SITE PLANNDESIGN CONTRACTOR CERTIFICATE OF COMPETENCY STAMP6030SCALE 1" = 30'1504575STREET CENTERLINEEXISTING HYDRANTEXISTING VALVENEW YARD POST INDICATOR BY OTHERSEXISTING UNDERGROUNDNEW FIRE DEPARTMENT CONNECTION BY UNDERGROUND CONTRACTORLEGENDWASHINGTON STATECERTIFICATE OF COMPETENCYFIRE PROTECTION SPRINKLER SYSTEMSPhilip Stoehr7792-0213-C Level 3Smith Fire Systems, Inc.SMITHFS1360TSignatureExpires12/31/18Date11/16/18SCOPE OF WORK CLARIFICATIONS EXCLUSIONS SMITH FIRE SYSTEMS INC. (SFS) WILL INSTALL (1) DRY SPRINKLER SYSTEM TOPROTECT THE COVERED LOADING/UNLOADING AND 1ST FLOOR UNHEATED STORAGEUNITS. SFS WILL INSTALL (3) WET SYSTEMS TO PROTECT THE 2ND - MEZZANINEFLOORS OF HEATED STORAGE SPACE. SFS WILL INSTALL (1) CLASS-I WET STANDPIPEWITH HOSE VALVES AT THE INTERMEDIATE LANDINGS. SFS WILL INSTALL A 500 GPMDIESEL FIRE PUMP TO SUPPLEMENT THE CITY WATER SUPPLY. THE SYSTEMS WILL BEINSTALLED PER NFPA-13 (2013), NFPA-14 (2013), NFPA-20 (2013) AND PER THE CITY OFRENTON.2. ALL GROOVED COUPLINGS TO BE RIGID TYPE UNLESS NOTED ( ||| ) WHICH ARE FLEXIBLE.GENERAL NOTES 1.SMITH FIRE SYSTEMS WILL BEGIN WORK INSIDE THE BUILDING AT A 6" SUPPLY AND6" FDC FLANGES LOCATED IN THE FIRST FLOOR FIRE PUMP/RISER ROOM.2.ALL AREAS PROTECTED BY THE WET SYSTEM MUST BE MAINTAINED BY OTHERS ATA MINIMUM OF 40° F. TO PREVENT FREEZING.3.THE TOP EAST-WEST WALL PANELS WILL BE LEFT OFF UNTIL SPRINKLER PIPING ISROUGHED IN. ANY REQUIRED HOLES IN PANELS WILL BE BY OTHERS.4.ROLL UP DOORS ARE MOUNTED LOW ENOUGH TO ALLOW FIRE SPRINKLER PIPINGTO PASS ABOVE THEM.5.ALL STORAGE TO BE MAINTAINED A MINIMUM OF 18" BELOW THE SPRINKLERDEFLECTOR.1.PAINTING OR LABELING OF PIPE.2.ELECTRICAL WIRING OF ANY KIND.3.FIRE ALARM SYSTEM OR MONITORING.4.STRUCTURAL REVIEW.5.UNDERGROUND WORK OF ANY KIND.DESIGN CRITERIA UN-HEATED STORAGEPER NFPA 13 - 2013 EDITION - ORDINARY HAZARD GROUP 21ST FLOOR STORAGE & COVERED LOADING/UNLOADINGORDINARY HAZARD GROUP 2DESIGN DENSITY: 0.20 GPM/SQ. FT. OVER 1500 SQ. FT.PER NFPA 13(2013) 11.2.3.2.5: FOR DRY PIPE SYSTEMS THE AREA OF SPRINKLER OPERATION SHALL BE INCREASED BY 30 PERCENT WITHOUT REVISING THE DENSITY.1500 SQ.FT. X 30% = 450 SQ.FT. + 1500 SQ.FT. = 1950 SQ.FT.FINAL DESIGN DENSITY: 0.20 GPM/SQ.FT. OVER 1950 SQ.FT.HEATED STORAGEPER NFPA 13 - 2013 EDITION - ORDINARY HAZARD GROUP 2BASE DESIGN DENSITY: 0.20 GPM/SQ.FT. OVER 1500 SQ.FT.SECTION 11.2.3.2.3.1 ALLOWS A REDUCTION IN THE DESIGN AREA WITHOUT REDUCING THE DENSITYWHERE LISTED QUICK-RESPONSE SPRINKLERS ARE USED THROUGHOUT AND WHEN ALL THEFOLLOWING CONDITIONS ARE MET: 1) WET PIPE SYSTEM. 2) LIGHT HAZARD OR ORDINARY HAZARD OCCUPANCY. 3) 20 FOOT MAXIMUM CEILING HEIGHT. 4) THE NUMBER OF SPRINKLERS IN THE DESIGN AREA SHALL NEVER BE LESS THAN FIVE. 5) THERE ARE NO UNPROTECTED CEILING POCKETS EXCEEDING 32 SQ. FT.2ND FLOOR STORAGE (INSIDE STORAGE): X = CEILING HEIGHT = 10'-0" Y = PERCENT REDUCTION TO DESIGN AREA Y = -3X / 2 + 55 Y = -3(10) / 2 + 55 = 40.0% REDUCTION 1500 X 40.0% = 600.0 SQ.FT. REDUCTION 1500 - 600 = 900.0 SQ. FT. DESIGN AREAFINAL DESIGN DENSITY: 0.20 GPM/SQ.FT. OVER 900.0 SQ.FT.3RD FLOOR STORAGE (INSIDE STORAGE): X = CEILING HEIGHT = 19'-6" Y = PERCENT REDUCTION TO DESIGN AREA Y = -3X / 2 + 55 Y = -3(19.5) / 2 + 55 = 25.75% REDUCTION 1500 X 25.75% = 386.25 SQ.FT. REDUCTION 1500 - 386.25 = 1,113.75 SQ. FT. DESIGN AREAFINAL DESIGN DENSITY: 0.20 GPM/SQ.FT. OVER 1,113.75 SQ.FT.MEZZANINE STORAGE (INSIDE STORAGE): X = CEILING HEIGHT = 11'-2" Y = PERCENT REDUCTION TO DESIGN AREA Y = -3X / 2 + 55 Y = -3(11.17) / 2 + 55 = 38.25% REDUCTION 1500 X 38.25% = 573.75 SQ.FT. REDUCTION 1500 - 443 = 926.25 SQ. FT. DESIGN AREAFINAL DESIGN DENSITY: 0.20 GPM/SQ.FT. OVER 926.25 SQ.FT.STANDPIPECLASS 1 PER NFPA 14 - 2013 EDITION, AND PER THE CITY OF RENTON:500 GPM @ 100 PSI AT THE MOST REMOTE STAIRWELL. 250 GPM AT EACH ADDITIONAL STAIRWELL UP TOA MAXIMUM OF 750 GPM.HYDRAULIC CALCULATION DATA630.5 GPM AT 104.4 PSI (0 GPM INSIDE HOSE ALLOWANCE)880.4 GPM AT 35.4 PSI (250 GPM TOTAL HOSE ALLOWANCE)DESIGN DENSITY : 0.20 GPM PER SQ. FT. OVER 1,950 SQ. FT.DEMAND AT CITY CONNECTION :DEMAND AT BASE OF RISER :NUMBER OFSPRINKLERSDRY SYSTEM SYSTEM NO. 11ST FLOOR STORAGEDESCRIPTIONAREASQ. FOOTAGEAREA15,322190202TOTALDRY SYSTEM CAPACITY: 371.6 GALLONS16,800750 GPM AT 147.4 PSI DESIGN DENSITY : 500 GPM @ 100 PSI (750 GPM TOTAL)DEMAND AT FDC :STANDPIPE SYSTEM / NORTH STAIRHYDRAULIC CALCULATION DATAHYDRAULIC CALCULATION DATA319.6 GPM AT 73.7 PSI (0 GPM INSIDE HOSE ALLOWANCE)569.6 GPM AT 20.0 PSI (250 GPM TOTAL HOSE ALLOWANCE)DESIGN DENSITY : 0.20 GPM PER SQ. FT. OVER 1,500 SQ. FT. DEMAND AT CITY CONNECTION :DEMAND AT BASE OF RISER :NUMBER OFSPRINKLERSDESCRIPTIONAREASQ. FOOTAGEAREA197TOTAL2ND FLOOR STORAGE15,317WET SYSTEM NO. 219715,317HYDRAULIC CALCULATION DATA431.7 GPM AT 115.8 PSI (0 GPM INSIDE HOSE ALLOWANCE)681.7 GPM AT 33.9 PSI (250 GPM TOTAL HOSE ALLOWANCE)DESIGN DENSITY : 0.20 GPM PER SQ. FT. OVER 1,500 SQ. FT. DEMAND AT CITY CONNECTION :DEMAND AT BASE OF RISER :NUMBER OFSPRINKLERSDESCRIPTIONAREASQ. FOOTAGEAREA234TOTAL3RD FLOOR STORAGE16,800WET SYSTEM NO. 323416,800HYDRAULIC CALCULATION DATA338.9 GPM AT 83.6 PSI (0 GPM INSIDE HOSE ALLOWANCE)588.9 GPM AT 20.0 PSI (250 GPM TOTAL HOSE ALLOWANCE)DESIGN DENSITY : 0.20 GPM PER SQ. FT. OVER 1,500 SQ. FT. DEMAND AT CITY CONNECTION :DEMAND AT BASE OF RISER :NUMBER OFSPRINKLERSDESCRIPTIONAREASQ. FOOTAGEAREA136TOTALMEZZANINE STORAGE9,670WET SYSTEM NO. 41369,670WATER SUPPLY INFORMATIONRESIDUALFLOWINGDATE OF TESTLOCATION OF TESTELEV. OF FLOW TEST:DATA SUPPLIED BYSTATICGPMPSIPSI52491,0002829 NE 3RD STREET (SOUTH END OF NEW BUILDING)5-18-17CITY OF RENTON PUBLIC WORKS315 FT. ABOVE SEA LEVELEXTERIOR COVERED LOADING1,47812ROLL GROOVED, PLAIN END ( FOR BUTT WELDING )ROLL GROOVED, PLAIN END ( FOR BUTT WELDING )ROLL GROOVED, PLAIN END ( FOR BUTT WELDING )ROLL GROOVED, PLAIN END ( FOR BUTT WELDING )ROLL GROOVED, PLAIN END ( FOR BUTT WELDING )ROLL GROOVED, PLAIN END ( FOR BUTT WELDING )STEEL PIPE ASTM E - 53 / ASTM A - 795 OR BETTEREND PREP TYPES ALLOWEDROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING )ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING )ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING )THREADED, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED1. ALL STEEL PIPE TO BE AS FOLLOWS UNLESS NOTED OTHERWISE:INTERNALDIAMETER1.3801.0490.1400.133WALLTHICKNESS2.7055.2954.3103.3342.2031.7280.0850.0830.1340.0950.0860.0868.2490.1880.1346.357PIPESIZE401 1/4140102 1/23541 1/228**610SCHEDULEEDDY FLOWEDDY FLOWEDDY FLOWEDDY FLOWEDDY FLOW** WALL THICKNESS PER NFPA # 130.0970.044WEIGHT OFWATER / PIPE1.8172.053CAPACITYIN GALLONS0.2981.1440.7580.4530.1220.1985.2997.14417.30011.2902.8603.9822.7840.08023.0301.649XXXXBXXCXXDFJHGKEXIT GATEENTRY / AXWVUTYEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGN.E. 3RD ST.EXISTINGBUILDINGEXISTINGBUILDINGEXISTINGBUILDINGEXISTINGBUILDINGEXISTINGBUILDINGBUILDING SQUARE FOOTAGE:LEVEL 116,800LEVEL 215,317LEVEL 316,800MEZZ 9,670TOTAL58,587 SQ. FT.CONSTRUCTION TYPE:II-BOCCUPANCY TYPE:S-1PARCEL NUMBER:20021217900004STOR HOUSE PHASE IVBUILDING E6"DI 6"DI12" DI12"DI 12" DI16" D I10" DI10" DI10" DI6"DIFDCFLNGSRCESP5251HAA1HALLHALLHALLHALLHALLHALLHALLHALLHALLHALLHALLHALLHGFEDCBA212314.5'1ST FLR325.5'2ND FLR335.5'3RD FLR345.5'MEZZ.354.8'T.O.W.11'-0"10'-0"10'-0"6'-11"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"5" THICK PAN-DECK ANDCONCRETE FLOOR DECK5" THICK PAN-DECK ANDCONCRETE FLOOR DECK5" THICK PAN-DECK ANDCONCRETE FLOOR DECK5" THICK PAN-DECK ANDCONCRETE FLOOR DECK5" THICK PAN-DECK ANDCONCRETE FLOOR DECK8" THICK CONCRETE SLAB ON GRADE8" THICK CONCRETE SLAB ON GRADESTANDING SEAM METAL ROOF OVER12" "Z" PURLINS WITH BATT INSULATION8" THICK CMU INTERIOR SHEAR WALLWALL SUPPORTED STRUCTURE, TYP.COIL UP DOORS, TYP.1ST FLOOR UN-HEATED STORAGE, TYP.1ST FLOOR UN-HEATED STORAGE, TYP.MEZZANINE HEATED STORAGE, TYP.2ND FLOOR - HEATED STORAGE, TYP.3RD FLOOR - HEATED STORAGE, TYP.3RD FLOOR - HEATED STORAGE, TYP.2ND FLOOR - HEATED STORAGE, TYP.RECEIVED11/19/2018 striplettBUILDING DIVISIONF18006376_V1 By: cthomas Date: 11/28/2018 FIRE DEPARTMENTFor Construction Subject toCorrections Noted in RedAPPROVED ABOVE FINISHED FLOORBOTTOM OF TRUSSBOTTOM OF PURLINBOTTOM OF JOISTBOTTOM OF DECKBOTTOM OF BEAMINSIDE FACE OF WALLUNLESS NOTED OTHERWISENO AUTO. SPRINKLERSOUTSIDE FACE OF WALLABBREVIATIONSBOPCTSBOTOFOWNASIFOWUNOFOCUT TO SUITFIELD ORDERAFFBODBOJBOBHYDRAULIC CALCULATION NODEFLEXIBLE COUPLINGRIGID COUPLINGELEVATION ABOVE REFERENCED2-WAY EARTHQUAKE SWAY BRACE4-WAY EARTHQUAKE SWAY BRACECENTERLINE OF PIPE TO REFERENCEDLETTER INDICATES TYPELETTER INDICATES TYPESTRUCTURE IN INCHESHANGER LOCATIONPOINT IN FEET AND INCHESAABOD12SYMBOL LEGENDREVISIONSREASON FOR REVISIONNO.BYDATEKEY PLANHANGER LEGENDSYMMANUFACTURERS.I.N.TYPEMODELSPRINKLERFINISHESCUTCHEONFINISHORIFICESIZETHREADSIZETEMP.RATINGQUANTITYSPRINKLER LEGENDTOTAL THIS SHEETOFFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.OFPROJECT MGRFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.PROJECT MGRTC18111THE STOR-HOUSEPHASE IV2829 NE 3RD STREETRENTON, WA 9805626M. MILLER11-16-18S. LAVINFIRE PUMP FLOOR PLANDESIGN CONTRACTOR CERTIFICATE OF COMPETENCY STAMP420SCALE 1/2"=1'-0"WASHINGTON STATECERTIFICATE OF COMPETENCYFIRE PROTECTION SPRINKLER SYSTEMSPhilip Stoehr7792-0213-C Level 3Smith Fire Systems, Inc.SMITHFS1360TSignatureExpires12/31/18Date11/16/18DIESEL FIRE PUMPFIRE PUMP OVERHEAD PLANN420SCALE 1/2"=1'-0"SECTION 'C/2'420SCALE 1/2"=1'-0"SECTION 'B/2'420SCALE 1/2"=1'-0"SECTION 'A/2'420SCALE 1/2"=1'-0"NFACING NORTHFACING WESTFACING SOUTHFITTER / LISTER NOTES: 1. PIPE ALL DRAINS TO SAFE DISCHARGE AT FLOOR DRAIN.3. RISER ROOM MUST BE MAINTAINED AT A MINIMUM OF 40° F.4. ALL COPPER CONTROLLER AND FUEL TANK PIPING TO BE INSTALLED AT A MINIMUM OF 8'-0" AFF, U.N.O.2. MAINTAIN 2" ANNULAR SPACE AROUND PIPES PASSING THROUGH CONCRETE FLOORS.QTYK-FACTOR MODELFINISHTHREADMANUFACTURERTYPESPARE SPRINKLERS & WRENCHESTEMPRELIABLERELIABLESSUSSPF156BRNZ5.6K1/2"155°3CHRM5.6K1/2"155°3RELIABLE MODEL "D", SPRINKLER WRENCHRELIABLE MODEL "GFR2", SPRINKLER WRENCH11RELIABLESSUF1FR56BRNZ5.6K1/2"155°5. SEE SHEET 3 OF 6 FOR BRACING DETAILS.1166" x 5"ANVIL STARFIG. 826FLANGED ECCENTRIC REDUCER 1N/APOTTER ELECTRICOSYSU-2VALVE SUPERVISORY SWITCHOS&Y GATE VALVE FxG8068KENNEDY8"1141574 H.P.(500 GPM @ 90 PSI)ITEMSIZEQTYDISCHARGE PRESSURE GAUGESUCTION PRESSURE GAUGEDIESEL FIRE PUMP DRIVER (74 HP @ 2,350 RPM, 120V HOT START)AUTOMATIC AIR RELEASE VALVEJOCKEY PUMP CONTROLLERJOCKEY PUMP (3 GPM @ 110 PSI)DESCRIPTIONFIRE PUMP EQUIPMENT LISTFIRE PUMP, CLOCKWISE ROTATIONDIESEL HORIZONTAL SPLIT CASEDESCRIPTION4AEF12MODEL--JU4H-UFAEF2PEERLESSFACTORY CHOICECLARKEMANUFACTURERBR081001CR3-8--FACTORY CHOICEEATONGRUNDFOSFACTORY CHOICE --OTHER EQUIPMENTMANUFACTURERMODEL5" x 4"SIZE1/4"1ITEM32111QTY1 1/2 HP1 1/2 HP1/2"76511141/4"1GROOVED CONCENTRIC REDUCERANVIL STARR-116" x 4"FIRE PUMP CONTROLLER FD120EATON--8117SWING CHECK VALVEVICTAULIC717H26"18BUTTERFLY VALVE W/BUILT IN TAMPER SWITCHVICTAULIC70546"19BUTTERFLY VALVE W/BUILT IN TAMPER SWITCHVICTAULIC70543"-4"253"-4"WATERFLOW INDICATOR POTTER ELECTRIC4VSR-F261/4"WATER PRESSURE GUAGE--4--271 1/4"-2"INSPECTORS TEST & DRAIN VALVE W/AGF4M1011T282.5"GROOVE ANGLE HOSE VALVEWILSON & COUSINS 2IE23G291 1/4"SWING CHECK VALVECENTRAL1F-18301 1/4"THREADED OS & Y GATE VALVEUNITED BRASS21812 HDSPARE SPRINKLER HEAD BOX CONTAINING THE FOLLOWING BELOW:1(3 PHASE, 60 CYCLE, 460 V)(3 PHASE, 60 CYCLE, 460V)RESIDENTIAL MUFFLER C06532CLARKE4"91DIESEL FUEL TANK SYSTEMS --FACTORY CHOICE115 GAL.110(DOUBLE WALL)1331PRESSURE RELIEF VALVE32--REMOTE FUEL GAUGE READERKRUEGER SENTRY GAUGE1--33--TANK LEAK SENSING FLOATFLOTRONIX1FLO-L10785SECTION 'E/2'420SCALE 1/2"=1'-0"FACING WESTRELIABLER2921SSUG XLOBRASS---11.2K3/4"200°22SECTION 'D/2'420SCALE 1/2"=1'-0"FACING WESTDIESEL FUEL TANK DETAILS420SCALE 1/2"=1'-0"12V BATTERY RACK (2 BATTERIES)--FACTORY CHOICE --111REDUCED PRESSURE DOUBLE DETECTOR475STDAWILKINS6"112CHECK VALVE ASSEMBLY20DRY PIPE VALVEINCLUDES THE FOLLOWING:RELIABLEEX-LP14"BUTTERFLY VALVE W/ TAMPER SWITCHMAIN DRAIN VALVE14"12"24400GAL.RISER MOUNTED AIR COMPRESSORGAST15LCA-22-M4550X23---AIR MAINTENANCE DEVICERELIABLE1A-2221/2"AIR PRESSURE SWITCHPOTTER ELECTRIC1PS40-2A211/2"PRESSURE ALARM SWITCHPOTTER ELECTRIC1PS10-2ACONTRACT WITHPROJECT MANAGER :PHONE :FAX :SUPERINTENDENT :PHONE :FAX :COLVOS CONSTRUCTION711 COURT CTACOMA, WA 98402BRIAN NEAL253-844-4640JEFF BIRD253-355-20886F1FR56302930TDIESELFIRE PUMPTTBOR1BOR2BOR4BOR3SPBR66(6-1)8"7'-3.5"1'-1"1'-5"6"-0"6(1-9)3'-0"1'-1"JOCKEY PUMPCONTROLLERFIRE PUMPCONTROLLERREQUIREDCLEAR SPACE, TYP.3'-0"8.5"8710DIESEL TANKBELOW121718188"1'-3.5"2'-9.5"8.5"25TO PUMPTEST HEADERFIRE SUPPLYFROM DDCVATO PUMPTEST HEADERIFOWIFOWAC17131516184.5"9"-0"1'-1"1'-6.5"1'-5"1'-5"1'-5"1'-5"IFOWIFOW6" FIRESUPPLY6" FDC SUPPLYBYPASSWET SYSTEM #22ND FLOORWET SYSTEM #33RD FLOORWET SYSTEM #4MEZZANINEDRY SYSTEM #11ST FLOORSTANDPIPERISERFIRE PUMPDISCHARGEFIRE PUMPTEST HEADER7'-5.5"FIRE PUMPTEST HEADER1'-1"9"FIRE PUMPSUCTIONFIRE PUMPTEST HEADER6(1-6)6(1-11)WA WAWAWAWAWAWA WAWA6(0-10.5)6(1-5)6(1-5)6(1-5)6(1-5)6(0-6)6(0-8.5)1.25(3-0) GOE 1.25(2-0) GOEP1P21'B/2''B/2''E/2''E/2''C/2''C/2''A/2''A/2'6(4-3.5)6(7-5.5)1'-11"1'-9"SUCTIONFLANGEDISCHARGEFLANGE6(0-6)111116(2-5.5)FLNGBF2BF11214'D/2''D/2'1422T14T TOR1TOR2TOR4TOR3SPTR3'-7.5"1'-1"1'-5"1'-5"1'-5" 3 (6-5) 3 (7-9.25)8"1'-3.5"2'-6"4'-0"25RISER MANIFOLDIFOW IFOWAC1'-5"1'-5"1'-6.5"1'-1"9"6"8" 1.5 10-0 1.5 4-8 1'-0"1'-0"8" BRANCHLINE4(3-11.5)4(0-2.5)4 (5-1.5)3 (0-4)3(0-7.5)3(1-1.5)3 (8-10)WET SYSTEM #4MEZZANINEWET SYSTEM #33RD FLOORWET SYSTEM #22ND FLOORWET SYSTEM #22ND FLOORWET SYSTEM #33RD FLOORWET SYSTEM #4MEZZANINEDRY SYSTEM #11ST FLOORSTANDPIPERISER4 (4-1)111111114(7-6)404040T T 4 (13-7)4(1-8)19194" BFY STANDPIPEISOLATION VALVESSP411'-0.5"STANDPIPE 1'-0"STANDPIPET6" FIRE SUPPLY (BY OTHERS)6" FDC (BY OTHERS)TWTWTWTWT?19191926261818278"8"3'-7.5"1'-1"AWET SYSTEM #4 MEZZANINE 6" FIRE SUPPLY 6" FDC SUPPLY BYPASS1'-0"1'-0"11.5"1'-5"1'-5"1'-5"1'-5"1'-6.5"1'-1"9"WET SYSTEM #3 3RD FLOOR WET SYSTEM #2 2ND FLOOR WET SYSTEM #4 MEZZANINE WET SYSTEM #2 2ND FLOOR WET SYSTEM #3 3RD FLOOR DRY SYSTEM #1 1ST FLOOR STANDPIPE RISER TO PUMP TEST HEADER FROM PUMP DISCHARGEIFOW IFOW1'-6.5"1'-0"1'-0"6 (0-7) FxGEPOXY 6 (0-6) FxG6(0-10.5)6(1-5)6(1-5)6(1-5)6(1-5)6(0-6)PIPE STAND, TYP.6 (4-9.75) 3 (1-7) 3 (1-7) 3 (1-7) 4 (1-7) 4 (1-7) 4 (2-7.25) 3 (2-8.75) 3 (2-8.75) 3 (2-8.75)3(7-9)1'-1"5'-5"1'-0" 6"7'-6"3'-0"314'-6" (L1)AFF325'-6" (L2)AFF6" 6 (4-3.75)6"3"3"3"4"4"6"6"7810C5.5"6"FLNGBOR3BOR4BOR2BOR1SPBRSP53 (1-1) 3 (1-1) 3 (1-1)SEE CONTINUATION ON SHEETS 5 AND 6, TYP.27DPVPPT272726212526202324SPTRTOR1TOR1TOR1TOR1111111111132 AC4 (2-4.75)226"EPOXY19252525EB(BY OTHERS)1'-0"4 (1-1)1STANDPIPETT6(6-1)8"1'-3.5"2'-9.5"3.5"25TO PUMP TEST HEADER FIRE SUPPLY FROM DDCVA TO PUMP TEST HEADER4"4"6"6"11617151314186"PIPE STAND, TYP.6" (0-3) FxG6 (4-9.75) 6 (5-4)IFOWIFOWWA WA 4.5"R1P1P21'-6"5'-5"1'-0"314'-6" (L1)AFF1'-0"1'-0"325'-6" (L2)AFF1'-1" 1'-7"6'-5"1'-0"1'-0"1'-0"6(0-8.5)1'-11"2'-2"SUCTION FLANGE DISCHARGE FLANGE1 115348"7'-3.5"AIFOW1'-1"1'-2"7'-5.5"1'-1"9"IFOW6" FIRESUPPLY6" FDC SUPPLYBYPASSTO PUMPTEST HEADERTO PUMPTEST HEADERFIRE SUPPLYPUMP SUCTION1'-7"6'-5"1'-0"314'-6" (L1)AFF1'-0"1'-0"325'-6" (L2)AFF6(5-1.5)6(7-5.5)6(4-3.5)1.25"6"6"6"6(5-4)WAWA WAWA6"2'-6"10"4"6(0-10)2828C6"6" B/B 45° ELL6(0-6)6(1-9)3111111296301.25" (0-6) TxG1.25" (0-3) NIPPLE1.25" x 1.25" x 1/2" TEE1.25" (0-3) NIPPLE(2) 1.25" (0-3) NIPPLE301.25" (0-6) TxG6" CONCRETE HOUSE-KEEPING PADJP SUCTIONSEE PUMP PLANON THIS SHEETJP DISCHARGESEE PUMP PLANON THIS SHEET(8) 3/8" NUTS & FENDER WASHERS(4) 3/8" X 6" ATR(4) 3/8" ROD COUPLING(4) 3/8" x 3 3/4" KWIK BOLT8"1'-3.5"256" FIRE SUPPLY TO FIRE PUMP SUCTIONIFOWIFOW1'-1"6"2'-11"314'-6" (L1)AFF325'-6" (L2)AFF6" 2'-0.5"5'-11.5"3'-0"1'-7"3'-6.5"6" FIRE SUPPLY (BY OTHERS)6(2-5.5)EPOXY 6" (0-6) FxGEPOXY 6"90° ELLFLNG6"6.5"3'-0" WA1BF2BF1M6(0-6)6 (2-4)PIPE STAND, TYP.6" STAINLESSSTEEL FILLER141412WA 3'-1"1'-4"BACKFLOW ASSEMBLY BACKFLOW ASSEMBLY EMERGENCY VENTFUEL RETURNAUX. VENT1/2 " RETURN LINE10LOCK OPEN BALL VALVEW/ TAMPER SWITCH1/2" SCH 40 FUELSUPPLY LINE(4) 2" PIPE STANDS1" DRAIN PLUG(4) FLANGED PIPE STANDS ENDSAUX. VENT LINE8888(8) BRACE #8'S88888 8 8 82" SCH-40 TANKSTAND, TYP.OUTLINE OF TANK ABOVESEE PLAN VIEW ABOVE1.25" (3-0) CTS FUEL VENT W/ ARRESTER TO OUTSIDE1.25" (6-0) CTS 1.25" x 1.25" X 1/2" TEE2" (9-0) CTS FUEL LINE TO OUTSIDE45° - 59°FROM VERTICAL33FUEL FILL &SPILL PROTECTORWIRE TANK LEAK SENSINGFLOAT BACK TO ALARM PANELCONCRETE FLOOR(4) 1/2" x 4-1/2" HILTI KWIK BOLT TZ(3-3/4" MIN. EMBED), TYP.1" (4-0) SCH-40 BRACE PIPE2" DIESEL TANK PIPE STANDTOLCO FIG. 4L PIPE CLAMPTOLCO FIG. 980 SWIVEL END32RECEIVED11/19/2018 striplettBUILDING DIVISIONF18006376_V1 ABOVE FINISHED FLOORBOTTOM OF TRUSSBOTTOM OF PURLINBOTTOM OF JOISTBOTTOM OF DECKBOTTOM OF BEAMINSIDE FACE OF WALLUNLESS NOTED OTHERWISENO AUTO. SPRINKLERSOUTSIDE FACE OF WALLABBREVIATIONSBOPCTSBOTOFOWNASIFOWUNOFOCUT TO SUITFIELD ORDERAFFBODBOJBOBHYDRAULIC CALCULATION NODEFLEXIBLE COUPLINGRIGID COUPLINGELEVATION ABOVE REFERENCED2-WAY EARTHQUAKE SWAY BRACE4-WAY EARTHQUAKE SWAY BRACECENTERLINE OF PIPE TO REFERENCEDLETTER INDICATES TYPELETTER INDICATES TYPESTRUCTURE IN INCHESHANGER LOCATIONPOINT IN FEET AND INCHESAABOD12SYMBOL LEGENDREVISIONSREASON FOR REVISIONNO.BYDATEKEY PLANHANGER LEGENDSYMMANUFACTURERS.I.N.TYPEMODELSPRINKLERFINISHESCUTCHEONFINISHORIFICESIZETHREADSIZETEMP.RATINGQUANTITYSPRINKLER LEGENDTOTAL THIS SHEETOFFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.OFPROJECT MGRFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.PROJECT MGRTC18111THE STOR-HOUSEPHASE IV2829 NE 3RD STREETRENTON, WA 9805636M. MILLER11-16-18S. LAVINDESIGN CONTRACTOR CERTIFICATE OF COMPETENCY STAMPWASHINGTON STATECERTIFICATE OF COMPETENCYFIRE PROTECTION SPRINKLER SYSTEMSPhilip Stoehr7792-0213-C Level 3Smith Fire Systems, Inc.SMITHFS1360TSignatureExpires12/31/18Date11/16/18DIESEL FIRE PUMP DETAILS0SCALE 1/4"=1'-0"48FIRE PUMP EXHAUST AND VENTING420SCALE 1/2"=1'-0"N420SCALE 1/2"=1'-0"FIRE PUMP EXHAUST PIPING420SCALE 1/2"=1'-0"NFIRE PUMP FUEL, VENT & CONTROLLER PIPINGFIRE PUMP EXHAUST SECTION 'A/3'420SCALE 1/2"=1'-0"NFLANGE LOCATION PLANDRAIN PIPING: 1/2" GALVANIZED SCH. 40CONTROLLER PIPING: 1/2" COPPER (TYPE L) PIPE****SEND STANDARD CONTROLLER AND DRAIN PIPING MATERIALS****FUEL PIPING: 1/2" SCH. 40FACING NORTHCONTRACT WITHPROJECT MANAGER :PHONE :FAX :SUPERINTENDENT :PHONE :FAX :COLVOS CONSTRUCTION711 COURT CTACOMA, WA 98402BRIAN NEAL253-844-4640JEFF BIRD253-355-2088TDIESELFIRE PUMPTT8"25AC1/2" SCH-40 FUELSUPPLY LINE1/2" SCH-40FUEL RETURN LINE2.5" TANK VENT LINEMIN 5'-0" APART DRILL 3/32" HOLE IN UNION MIN 5'-0" APART DRILL 3/32" HOLE IN UNION2.5" FUEL VENT LINE2.5" AUX. TANK VENT LINEFLASH ARRESTOR, TYP.12211'-0"10'-0"10'-0"7'-4"38'-4"9'-0"4'-8"1'-0"1'-0"2'-0"9'-0"12'-0"12'-10"3'-4"NFPA 20 - 11.5.3 EXHAUST DISCHARGE LOCATION.11.5.3.1 EXHAUST FROM THE ENGINE SHALL BE PIPED TO A SAFE POINT OUTSIDETHE PUMP ROOM AND ARRANGED TO EXCLUDE WATER.11.5.3.2 EXHAUST GASES SHALL NOT BE DISCHARGED WHERE THEY WILL AFFECTPERSONS OR ENDANGER BUILDINGS.11.5.3.3 EXHAUST SYSTEMS SHALL TERMINATE OUTSIDE THE STRUCTURE AT APOINT WHERE HOT GASES, SPARKS, OR PRODUCTS OFCOMBUSTION WILL DISCHARGE TO A SAFE LOCATION.11.5.3.4 EXHAUST SYSTEM TERMINATIONS SHALL NOT BE DIRECTED TOWARDCOMBUSTIBLE MATERIAL OR STRUCTURES, OR INTO ATMOSPHERESCONTAINING FLAMMABLE GASES, FLAMMABLE VAPORS, OR COMBUSTIBLE DUSTS.NFPA 30 - 27.8.1 VENT PIPING FOR ABOVEGROUND STORAGE TANKS27.8.1.1 WHERE THE OUTLETS OF VENT PIPES FOR TANKS STORINGCLASS I LIQUIDS ARE ADJACENT TO BUILDINGS OR PUBLIC WAYS,THEY SHALL BE LOCATED SO THAT VAPORS ARE RELEASED AT A SAFEPOINT OUTSIDE OF BUILDINGS AND NOT LESS THAN 12FT ABOVETHE ADJACENT GROUND LEVEL.27.8.1.3 VENT OUTLETS SHALL BE LOCATED SO THAT VAPORS WILLNOT BE TRAPPED BY EAVES OR OTHER OBSTRUCTIONS AND SHALLBE AT LEAST 5FT. FROM BUILDING OPENINGS AND AT LEAST 15FT.FROM POWERED VENTILATION AIR INTAKES.SPARK ARRESTORS, TYP.(1) VENT, (2) EMERGENCY252423314'-6"1ST FLOOR325'-6"2ND FLOOR335'-6"3RD FLOOR345'-6"MEZZANINE354'-8"T.O.W.TDIESELFIRE PUMPT8"25AC4" 8-0 SCH-4045° CUT AND WELD INSCREEN X PLAIN END7'-4" CENTERLINE OF EXHAUSTWEATHER STOP10"1'-2"1'-0"1'-0"?4" (8-0) SCH-40 FxF4" RESIDENTIALMUFFLER'A/3''A/3'8"13'-0.5"AIFOW5'-9.5"IFOWDIESEL FIRE PUMP EXHAUST 4" RESIDENTIAL MUFFLERFLEX CONNECTORW/ 4" FLANGE9'-0"314'-6" (L1)AFF325'-6" (L2)AFF4" (4-0) SCH-40 FxFWEATHER STOPWELD IN SCREEN4" (8-0) SCH-40 FxF11'-0"A6"4"4" FLG 90° EL TYP.4" (INSULATION)921782524CBA6" F D C F L A N G E@ 6 " A F F6" FIRE SUPPLY FLANGE@ 6 " A F F 1'-1"7'-3.5"11.5"1'-11.5"1'-3.5"8"8'-0.5"FLANGEFLANGE FLOOR DRAINBY OTHERS9"FLANGEFLANGEFIRE PUMPHOUSEKEEPING PAD2"8'-6"5'-2"1'-7.5"OUTLINE OF FOOTING BELOW, TYP.9'-3"RECEIVED11/19/2018 striplettBUILDING DIVISIONF18006376_V1 ABOVE FINISHED FLOORBOTTOM OF TRUSSBOTTOM OF PURLINBOTTOM OF JOISTBOTTOM OF DECKBOTTOM OF BEAMINSIDE FACE OF WALLUNLESS NOTED OTHERWISENO AUTO. SPRINKLERSOUTSIDE FACE OF WALLABBREVIATIONSBOPCTSBOTOFOWNASIFOWUNOFOCUT TO SUITFIELD ORDERAFFBODBOJBOBHYDRAULIC CALCULATION NODEFLEXIBLE COUPLINGRIGID COUPLINGELEVATION ABOVE REFERENCED2-WAY EARTHQUAKE SWAY BRACE4-WAY EARTHQUAKE SWAY BRACECENTERLINE OF PIPE TO REFERENCEDLETTER INDICATES TYPELETTER INDICATES TYPESTRUCTURE IN INCHESHANGER LOCATIONPOINT IN FEET AND INCHESAABOD12SYMBOL LEGENDREVISIONSREASON FOR REVISIONNO.BYDATEKEY PLANHANGER LEGENDCERTIFICATE OF COMPETENCY STAMPSYMMANUFACTURERS.I.N.TYPEMODELSPRINKLERFINISHESCUTCHEONFINISHORIFICESIZETHREADSIZETEMP.RATINGQUANTITYSPRINKLER LEGENDTOTAL THIS SHEETOFFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.OFPROJECT MGRFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.PROJECT MGRTC18111THE STOR-HOUSEPHASE IV2829 NE 3RD STREETRENTON, WA 9805646M. MILLER11-16-18S. LAVINSTANDPIPES AND DETAILSWASHINGTON STATECERTIFICATE OF COMPETENCYFIRE PROTECTION SPRINKLER SYSTEMSPhilip Stoehr7792-0213-C Level 3Smith Fire Systems, Inc.SMITHFS1360TSignatureExpires12/31/18Date11/16/18SOUTH STAIR PLAN VIEWS0SCALE 1/4"=1'-0"48NSECTION 'B/4'0SCALE 1/4"=1'-0"48SOUTH STAIR (FACING NORTH)NORTH STAIR PLAN VIEWS0SCALE 1/4"=1'-0"48NSECTION 'A/4'0SCALE 1/4"=1'-0"48NORTH STAIR (FACING NORTH)SECTION 'C/4'0SCALE 1/4"=1'-0"48(FACING SOUTH)EQ. BRACE ' 1 'EQ. BRACE ' 2 'EQ. BRACE ' 3 'EQ. BRACE ' 4 'EQ. BRACE ' 5 'EQ. BRACE ' 6 'HANGER ' CP 'HANGER ' SB 'HANGER ' TB 'HANGER ' PT 'CONTRACT WITHPROJECT MANAGER :PHONE :FAX :SUPERINTENDENT :PHONE :FAX :COLVOS CONSTRUCTION711 COURT CTACOMA, WA 98402BRIAN NEAL253-844-4640JEFF BIRD253-355-2088UP314.51ST FLOORDNUPDNUPDNH10'-0"1ST FLOOR2ND FLOOR3RD FLOORMEZZANINE2524GF8'-8"10'-0" 0'-8" 8'-0"320.3LANDING0'-8"0'-8"0'-8"0'-8"330.5LANDING340.5LANDING340.5LANDING325.52ND FLOOR335.53RD FLOOR345.5MEZZANINEH10'-0"2524GF8'-8"10'-0" 0'-8" 8'-0" 0'-8"0'-8"0'-8"0'-8"H10'-0"2524GF8'-8"10'-0" 0'-8" 8'-0" 0'-8"0'-8"0'-8"0'-8"H10'-0"2524GF8'-8"10'-0" 0'-8" 8'-0" 0'-8"0'-8"0'-8"0'-8"4(1-7)4 (4-10)B4B4B4B44" TORISER ROOMH10'-0"GF8'-8"1'-4"11'-0"10'-0"10'-0"7'-4" 38'-4"314'-6"1ST FLOOR325'-6"2ND FLOOR335'-6"3RD FLOOR345'-6"MEZZANINE354'-8"T.O.W.319'-9.5"LANDING330'-5"LANDING340'-6"LANDING13'-0"2'-6"3'-0" 4 (1-6) 4 (2-6) 4 (1-6) 4 (6-6) 4 (2-0) 4 (5-0)14 (1-2.5)STAIRSOUTHSTAIRSOUTHSTAIRSOUTHSTAIRSOUTH4" TORISER ROOMSP42.5" BRASS GRVD ANGLE HOSE VALVEW/ CAP AND CHAIN WILSON & COUSINSMODEL NO. IE23G, TYPICALUPUPDNUPDNDN1ST FLOOR2ND FLOOR3RD FLOORMEZZANINE340.5LANDING345.5MEZZANINE340.5LANDING335.53RD FLOOR330.5LANDING325.52ND FLOOR314.51ST FLOOR319.8LANDINGH10'-0"21GF8'-8"10'-0"0'-8"8'-0"0'-8"0'-8"0'-8"0'-8"H10'-0"21GF8'-8"10'-0"0'-8"8'-0"0'-8"0'-8"0'-8"0'-8"H10'-0"21GF8'-8"10'-0"0'-8"8'-0"0'-8"0'-8"0'-8"0'-8"H10'-0"21GF8'-8"10'-0"0'-8"8'-0"0'-8"0'-8"0'-8"0'-8"A4A4A4A44(1-7)SEE 2ND FLOOR PLANFOR CONTINUATIONSP2SP113'-0"2'-6"3'-0"12'-0"10'-0"10'-0"7'-4"39'-4"313'-6"1ST FLOOR325'-6"2ND FLOOR335'-6"3RD FLOOR345'-6"MEZZANINE354'-8"T.O.W.319'-9.5"LANDING330'-5"LANDING340'-6"LANDINGH10'-0"GF8'-8"1'-4"4(1-6)4(0-9)4(2-6)4(1-6)4(5-4)4(0-4)4(2-0)4(6-8.5)1SEE 2ND FLOOR PLANFOR CONTINUATIONSTAIRNORTHSTAIRNORTHSTAIRNORTHSTAIRNORTHSP1SP22.5" BRASS GRVD ANGLE HOSE VALVEW/ CAP AND CHAIN WILSON & COUSINSMODEL NO. IE23G, TYPICALA1'-4"1'-0"1'-0"E39'-6"0'-6"3 (5-9) 3 (8-6) 3 (8-6)3 (1-2.5)3 (1-7) 3 (1-6) 3 (5-9) 3 (1-7)3 (5-9) 3 (1-6) 3 (1-7) 11'-0"10'-0"10'-0"7'-4" 38'-4"314'-6"1ST FLOOR325'-6"2ND FLOOR335'-6"3RD FLOOR345'-6"MEZZANINE354'-8"T.O.W.WET SYSTEM #4 (MEZZANINE) WET SYSTEM #3 (3RD FLOOR) WET SYSTEM #2 (2ND FLOOR) WET SYSTEM #4 (MEZZANINE) 3 (1-2.5)FIRE PUMP/RISER ROOMSEE DETAIL 'A/4' FORCONTINUATION, TYP.41111111202030204040404 (1-7) 4 (4-11)1'-0"STANDPIPE1 SP34 (1-6) 4 (8-6) 4 (1-2.5)145°( 2 ) TOLCO FIG. 980SWIVEL END45°1/2" x 4 1/2" HILTI KWIK BOLT TZ( 3 3/4" MIN. EMBED )(2) 1" MIN EXCESS PIPETHROUGH FAST CLAMP(2) 1" x (3-6) SCH-40 BRACE PIPE(2) TOLCO FIG 1001FAST CLAMPCONCRETE PAN DECK1/2" x 4 1/2" HILTI KWIK BOLT TZ( 3 3/4" MIN. EMBED )CONCRETE FLOOR1" (3-6) SCH-40 BRACE PIPE1" MIN EXCESS PIPETHROUGH FAST CLAMP60° - 90 °TOLCO FIG. 980SWIVEL ENDTOLCO FIG. 1001 BRACE CLAMPTOLCO FIG. 980 SWIVEL END1/2" x 4 1/2" HILTI KWIK BOLT TZ( 3 3/4" MIN. EMBED )60° - 90°FROM VERTICALCONCRETE FLOOR1" (3-6) SCH-40 BRACE PIPETOLCO FIG. 4LPIPE CLAMP45°FLANGE OF Z-PURLIN( 2 ) TOLCO FIG. 980SWIVEL END(2) 1" x (7-0) SCH-40 BRACE PIPE( 2 ) 1/2" x 1 1/2" BOLT W/NUT & WASHER45°(2) TOLCO FIG 1001FAST CLAMP(2) 1" MIN EXCESS PIPETHROUGH FAST CLAMPTOLCO FIG. 980 SWIVEL END1/2" x 1 1/2" BOLTW/ NUT AND WASHERRIGID FRAME60° - 90°TOLCO FIG. 4LPIPE CLAMP1" (7-0) SCH-40 BRACE PIPEPOST212" x 212" x 6'-0" ANGLE WITH(2) 12" x 112" BOLT, WASHER, NUT1" (7-0) SCH-40 BRACE PIPE8x212" 16GA Z-PURLIN( 2 ) TOLCO FIG. 980SWIVEL END(1) TOLCO FIG 1001FAST CLAMP60°-90°212" x 212" x 12" ANGLE WITH(2) 12" x 112" BOLT, WASHER, NUT(1) 1/2" x 1 1/2" BOLT W/NUT & WASHER0'-1 1/2"0'-9"0'-1 1/2"0'-6"(3) 9/16" Ø HOLES(2) 1/4 X1"TEK SCREWMETAL DECKTOLCO FIG. 783/8" CEILING PLATEHANGER RING3/8" ATR(2) 1/4" x 1" TEK SCREWS14GA 8"x212" C-CHANNEL (2ND FLR)3/8" ATRHANGER RINGHANGER ASSEMBLY RATEDFOR 4" PIPE INTO 16GA STEELEQEQTOLCO FIG. 583/8" SIDE BEAMBRACKET3/8" x ATRHANGER RING3/8" TOP BEAM CLAMP12" RETAINER STRAP2" SCH-10 ( 6-0 ) TRAPEZE PIPE3/8" ATR3/8" ROD x 9" LONGWELD TO EACH END3" HANGER RING2" HD HANGER RINGZ - PURLINS @ 5'-0" O.C.4'-0"1'-0"(2) 1/4" x 1" TEK SCREWSEQEQZ - PURLIN12" x 2 12" 14GA3/8" ATRHANGER RINGRECEIVED11/19/2018 striplettBUILDING DIVISIONF18006376_V1 RELOCATE STANDPIPEOUTLETS TO THE FLOORLANDINGS, NOT THEINTERMEDIATE LANDINGS,TYPICAL ALL STAIRWAYS. ABOVE FINISHED FLOORBOTTOM OF TRUSSBOTTOM OF PURLINBOTTOM OF JOISTBOTTOM OF DECKBOTTOM OF BEAMINSIDE FACE OF WALLUNLESS NOTED OTHERWISENO AUTO. SPRINKLERSOUTSIDE FACE OF WALLABBREVIATIONSBOPCTSBOTOFOWNASIFOWUNOFOCUT TO SUITFIELD ORDERAFFBODBOJBOBHYDRAULIC CALCULATION NODEFLEXIBLE COUPLINGRIGID COUPLINGELEVATION ABOVE REFERENCED2-WAY EARTHQUAKE SWAY BRACE4-WAY EARTHQUAKE SWAY BRACECENTERLINE OF PIPE TO REFERENCEDLETTER INDICATES TYPELETTER INDICATES TYPESTRUCTURE IN INCHESHANGER LOCATIONPOINT IN FEET AND INCHESAABOD12SYMBOL LEGENDREVISIONSREASON FOR REVISIONNO.BYDATEKEY PLANHANGER LEGENDCERTIFICATE OF COMPETENCY STAMPSYMMANUFACTURERS.I.N.TYPEMODELSPRINKLERFINISHESCUTCHEONFINISHORIFICESIZETHREADSIZETEMP.RATINGQUANTITYSPRINKLER LEGENDTOTAL THIS SHEETOFFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.OFPROJECT MGRFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.PROJECT MGRTC18111THE STOR-HOUSEPHASE IV2829 NE 3RD STREETRENTON, WA 9805656M. MILLER11-16-18S. LAVINFIRST & SECOND FLOOR SPRINKLER PLANWASHINGTON STATECERTIFICATE OF COMPETENCYFIRE PROTECTION SPRINKLER SYSTEMSPhilip Stoehr7792-0213-C Level 3Smith Fire Systems, Inc.SMITHFS1360TSignatureExpires12/31/18Date11/16/18N420SCALE 1/2"=1'-0"N2ND FLOOR SPRINKLER PLAN1608SCALE 1/8"=1'-0"N1ST FLOOR SPRINKLER PLAN1608SCALE 1/8"=1'-0"PUMP ROOM OVERHEAD PLAN 'A/5'DRY PENDENT DETAIL 'C/5'INSPECTOR'S TEST DETAIL 'B/5'420SCALE 1/2"=1'-0"ELEVATOR PIT DETAILRELIABLERA1425SSUF1FR56BRASS---5.6K1/2"155°358RELIABLER2921SSUG XLOBRASS---11.2K3/4"200°2RELIABLERA1435HSWF1FR56BRASS---5.6K1/2"155°2RELIABLER5714DSSPF3QRCHRCHR5.6K1"155°12399RELIABLERA1414REC'D SSPF1FR56CHRMCHRM5.6K1/2"155°23RELIABLER5734DHSWF3QRCHRCHR5.6K1"155°2STUB-UP DETAIL 'D/5'DRY PENDENT DETAIL 'E/5'FITTER / LISTER NOTES1. BRANCHLINES ARE TO BE INSTALLED AT 5" BOD, UNO.2. MAINS ARE TO BE INSTALLED AT 14" BOD, UNO.3. ALL BRANCHLINE HANGERS ARE TO BE '3CP', UNO.4. ALL MAIN HANGERS ARE TO BE '6SB', UNO.5. RISER NIPPLES THIS LEVEL ARE TO BE GRV SN TO SN, UNO.6. DENOTES NON-COMBUSTIBLE BAFFLE, UNO.7. LATERAL BRACES CAN BE OMITTED AS PER NFPA #13, 2013 ED.SECTION 9.3.5.5.10 "THE (LATERAL BRACING) REQUIREMENTS...SHALL NOT APPLY TO PIPES INDIVIDUALLY SUPPORTED BYRODS LESS THAN 6 in. LONG MEASURED BETWEEN THE TOP OFTHE PIPE AND THE POINT OF ATTACHMENT TO THE BUILDINGSTRUCTURE.".CONTRACT WITHPROJECT MANAGER :PHONE :FAX :SUPERINTENDENT :PHONE :FAX :COLVOS CONSTRUCTION711 COURT CTACOMA, WA 98402BRIAN NEAL253-844-4640JEFF BIRD253-355-2088UPDNELEV. # 1ELEV. # 2UPDN240'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"3'-0"5'-0"70'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"25ABCDEFGH2423222120191817161514131211109876543215'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"4'-4"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"3'-0"5'-0"5'-0"3'-0"4'-6"8'-0"2'-0"2'-0"2'-6"0'-8"2'-0"TBTB1.5 10-0 1.5 10-0 1.5 3-0 TBTB1.5 10-0 1.5 10-0 TBTB1.5 10-0 1.5 10-0 1.5 3-0 TBTB1.5 10-0 1.5 10-0 1.5 3-0 312-6311-031-6312-635-11.5 3-0 W30x108W36x194W36x194W12x26W12x26W12x26 W12x26W12x26W12x26 1.512-61.57-31.52-01.57-01.54-01.52-01.52-61.58-01.56-01.56-11 TB TB TB TB 1.56-31.5 23-2 TBTB1.512-61.57-31.52-01.57-01.54-01.52-01.52-61.58-01.56-01.56-11 1.5 12-6 1.5 7-3 1.5 2-0 1.5 7-0 1.5 4-0 1.5 2-0 1.5 2-6 1.5 8-0 1.5 6-0 1.5 6-11 1.5 2-0 1.5 7-0 1.5 4-0 1.5 2-0 1.5 2-6 1.5 8-0 1.5 6-0 1.5 6-11 1.5 12-6 1.5 7-3 1.5 2-0 1.5 7-0 1.5 4-0 1.5 2-0 1.5 2-6 1.5 8-0 1.5 6-0 1.5 6-11 1.5 12-6 1.5 7-3 1.5 2-0 1.5 7-0 1.5 4-0 1.5 2-0 1.5 2-6 1.5 8-0 1.5 6-0 1.5 6-11 1.5 8-0 1.5 6-0 1.5 6-11 1.5 3-0 1.5 2-6 1.5 6-0 1.5 7-0 1.58-01.56-01.56-11 1.52-6 1.56-0 1.57-0 1.512-61.57-31.52-01.56-01.56-11 1.58-6 1.50-6 1.57-6 1.55-6 1.512-61.57-31.52-01.56-01.56-11 1.58-6 1.50-6 1.57-6 1.55-6 1.512-61.57-31.56-01.56-11 1.58-6 1.50-6 1.57-6 1.55-6 1.5 12-6 1.5 7-3 1.5 2-0 1.5 6-0 1.5 6-11 1.5 8-6 1.5 0-6 1.5 7-6 1.5 5-6 1.5 12-6 1.5 7-3 1.5 2-0 1.5 6-0 1.5 6-11 1.5 8-6 1.5 0-6 1.5 7-6 1.5 5-6 1.5 12-6 1.5 7-3 1.5 2-0 1.5 6-0 1.5 6-11 1.5 8-6 1.5 0-6 1.5 7-6 1.5 5-6 1.5 12-6 1.5 7-3 1.5 2-0 1.5 6-0 1.5 6-11 1.5 8-6 1.5 0-6 1.5 7-6 1.5 5-6 1.5 12-6 1.5 7-3 1.5 12-6 1.5 7-3 1.5 8-0 1.5 2-8 1.5 2-0 1.5 4-0 1.5 6-0 1.5 6-11 1.5 2-0 1.5 8-0 1.5 6-6 1.5 2-0 1.5 4-0 1.5 7-01.52-61.5 2-0 1.52-0 1.52-0 1.57-61.510-01.52-0 1.54-01.57-6 1.54-0 1.54-0 1.57-0 1.5 2-0 1.5 2-0 1.5 8-0 1.5 2-6 1.5 4-0 1.5 6-0 1.5 7-0 1.5 7-6 1.5 6-0 1.52-61.5 1-6 1.53-01.56-11 1.52-61.52-0 39BOD40.5BOD51.5 BOD 3 1-053 BOD 3(6-1.5)3" DN TO 1ST FLOOR DRY SYSTEM #1110-0110-01.5 0-6 1.5 0-6 1.5 6-0 1.52-61.5 7-6 1.5 1-6 1.5 8-0 1.5 6-6 1.5 2-0 1.5 4-0 1.5 7-01.52-61.5 6-11 1.5 2-0 1.5 7-6 1.5 4-0 1.5 4-0 1.5 7-0 1.5 2-0 1.5 7-6 1.5 4-0 1.5 4-0 1.5 7-0 1.5 7-6 1.5 10-0 1.5 2-0 1.5 4-0 1.5 2-0 1.5 7-0 1.5 4-0 1.5 2-0 1.5 4-0 1.5 7-6 1.5 3-0 1.52-61.5 6-11 1.5 2-0 1.5 11-0 1.5 8-0 1.5 10-0 1.5 10-0 1.5 1-8 16-643-442-04" STANDPIPE1.5 8-0 1 7-0 1 7-0 1.5 8-0 1.5 6-0 1.5 2-0 1.5 6-0 1.5 2-0 1.5 1-0 1.5 1-0 1.5 2-0 1.5 2-0 1.5 5-0 1.5 5-0 1.5 3-0 1.5 3-0 1.5 1-0 1.5 1-0 1.5 2-0 4 7-4 36-636-037-633-636-6310-037-632-6310-0310-036-032-632-637-635-632-032-633-636-639-636-633-632-637-633-636-637-632-632-635-032-6310-0310-038-6310-035-634-637-04(24-0)4(24-0)4(24-0)4(24-0)4(24-0)4(24-0)4(24-0)4(24-0)46-731-61.5 2-030-61.5 2-0 1.52-031-632-01.511-01.510-331-031-9310-0311-031-7313-4311-817-01.52-54" STANDPIPE1.53-04(24-0)45-45BOD 5BOD5BOD5BOD9'-0" AFFSP2SP335-014'-4" AFF14'-4" AFFCOVEREDLOADING/UNLOADINGSEE DETAIL 'C/4' ON SHEET 4 OF 6, U.N.O.1" DN TO INSPECTOR'S TEST, 'B/5'SEE DETAIL 'C/5' ON THIS SHEET, TYP. (12), U.N.O.12 3123456781020201202203204205206207208209210211212213214HYDRAULICALLY MOST DEMANDING AREA: WET SYSTEM NO. 2SYSTEM DEMAIND AT BASE OF RISER: 319.6 GPM @ 73.7 PSIINCLUDING (0) GPM FOR INSIDE HOSE ALLOWANCE1.5" (0-4)R.N.,TYP.1.5" (0-4)R.N.,TYP.DETAIL E/52 2 2 2 2 2 2 22 2 22 2 2 2 2 2 2 23333332222424-5247-041-8411-3 EQUIP.ELEV. # 1ELEV. # 2ELEV.TOILETUNI-SEXELECT.UPUP240'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"3'-0"5'-0"70'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"25ABCDEFGH2423222120191817161514131211109876543211.510-01.512-0 1.511-5 1.50-7 1.510-0 1.52-0 1.510-0 1.512-01.512-0 1.511-5 1.50-7 1.510-0 1.52-0 1.510-0 1.512-01.512-0 1.511-5 1.50-7 1.510-0 1.510-0 1.512-01.510-0 1.510-0 1.53-0 1.52-0 1.53-0 1.58-0 1.52-0 1.510-0 1.510-01.510-0 1.510-0 1.53-0 1.52-0 1.53-0 1.58-0 1.52-0 1.510-0 1.510-0 1.5 8-0 1.5 7-8 1.5 10-0 1.5 10-0 1.5 8-0 1.5 7-8 1.5 10-0 1.5 10-0 1.5 8-0 42-0 1.5 12-0 1.5 11-5 1.5 0-7 1.5 10-0 1.5 2-0 1.5 10-0 1.5 12-0 1.5 12-0 1.5 11-5 1.5 0-7 1.5 10-0 1.5 2-0 1.5 10-0 1.5 12-0 1.5 12-0 1.5 11-5 1.5 0-7 1.5 10-0 1.5 2-0 1.5 10-0 1.5 12-0 1.5 12-0 1.5 11-5 1.5 0-7 1.5 10-0 1.5 2-0 1.5 10-0 1.5 12-0 1.5 10-0 1.5 10-0 1.5 3-0 1.5 2-0 1.5 3-0 1.5 8-0 1.5 2-0 1.5 10-0 1.5 10-0 1.5 10-0 1.5 10-0 1.5 3-0 1.5 2-0 1.5 3-0 1.5 8-0 1.5 2-0 1.5 10-0 1.5 10-0 1.5 10-0 1.5 10-0 1.5 3-0 1.5 2-0 1.5 3-0 1.5 8-0 1.5 2-0 1.5 10-0 1.5 10-0 1.5 8-0 1.5 10-0 1.5 10-0 1.5 3-0 1.5 3-0 1.5 3-0 1.5 2-0 1.5 4-0 1.5 1-8 1.5 4-0 1.5 1-8 1.5 2-0 1.5 4-0 1.5 2-0 1.5 1-8 1.5 10-0 1.2510-01.251-81 6-0 10-61 2-11 1 6-0 1 6-011-810-61 1-6 1.5 10-0 1.5 6-7 1.5 7-0 1.5 3-0 1.5 7-0 1.52-61.53-0 1.57-0 1.52-61.52-010-616-0 16-016-011-611-8T10-612-111.251-81.2510-0(2) 10"(2) 12"(2) 12"(2) 12"(2) 10" (2) 12" (2) 10" (2) 10" (2) 10" W12x26 W12x26 W12x26 W12x58W12x261.5 3-0 1.5 2-0W12x261.5 7-0 1.5 3-0 1.5 2-0 1.5 1-8 1.5 2-0 36-61.5 2-0 1.5 4-0 1.5 7-0 1.5 10-0 1.5 4-0 3 1-0 3 9-0 3 1-0 3 4-6 3 4-6 3 6-0 1.52-01.57-6 1.54-0 1.54-0 1.57-0 1.5 6-0 1.5 2-0 1.5 6-0 1.5 1-0 1.5 2-0 1.5 1-0 1.5 2-0 1.5 1-0 1.5 2-0 1.5 1-0 1.5 6-0 1.5 6-0 1.5 6-0 1.5 8-0 1.5 2-0 1.5 2-0 1.5 8-0 1.5 1-0 1.5 1-0 1.5 6-0 1.5 2-0 1.5 1-0 1.5 1-0 1.5 6-0 1.5 2-0 1.5 6-0 1.5 5-0 3 7-0 (2) 10"(2) 10"(2) 12"(2) 12" 1.5 1-0 1.5 1-0 36-01011021031041051061071081091101.5 2-0 11511111211311411611712212312512112412011911812341.5 3-06781.5 3-0 1.5 1-032-0910111216T106T107T108T1093 1-0 1.5 6-10 1.5 1-2 15-01.5 7-0 1.5 1-0 110-0110-0116-911-75'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"4'-4"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"3'-0"5'-0"5'-0"3'-0"4'-6"8'-0"2'-0"2'-0"2'-6"0'-8"2'-0"1.510-0 11-81 (2-0)11-81(3-0)33-6 31-032-8 47-618BOD18BOD19 BOD 18BOD 15 BOD 410-0410-04(4-1)1.54-4 1.59-01.51-01.59-01.51-0 1.5 1-0 1.5 8-7 1.5 3-5 3(6-1.5)3" UP TO COVERED LOADING/UNLOADING(SEE 2ND FLOOR SPRINKLER PLAN FOR CONTINUATION)OPEN TO ABOVEM.T.M.T.M.T.M.T.M.T.M.T.M.T.30-639-634-6M.T.35-634-6310-0310-034-6M.T.33-0310-0310-033-6M.T.M.T.M.T.M.T.M.T.M.T.44-642-243-0 41-046-041-049-041-044-4 12" SLAB STEP @ G/L 10, TYP.314.5'F.F.313.5'F.F.314.5'F.F.313.5'F.F.12" SLAB STEP @ G/L 10, TYP.19BODSEE DETAIL 'A/5' ON THIS SHEET48-45BOD 5BOD5BOD5BOD9'-0" AFF9'-0" AFF9'-0" AFF1.5 2-0FIRE PUMP8'-0" AFF SP4COVEREDLOADING/UNLOADINGSEE ELEVATOR PIT DETAILON THIS SHEET, U.N.O.222 2 2 2 2 2 22221.54-82 3 3333 114204" X 3" R.C.45-4410-048-8410-0410-046-0410-045-841-033-442-841-4HYDRAULICALLY MOST DEMANDING AREA: DRY SYSTEM NO. 1SYSTEM DEMAIND AT BASE OF RISER: 630.5 GPM @ 104.4 PSIINCLUDING (0) GPM FOR INSIDE HOSE ALLOWANCE1.5" R.N.(FIELDORDER,TYP.)1.5" R.N.(FIELDORDER,TYP.)DETAIL E/5DETAIL D/5DETAIL E/5TT41-41.52-03 13-0 32-0319-822 TOR1TOR2TOR4TOR3SPTR3'-7.5"1'-1"1'-5"1'-5"1'-5" 3 (6-5) 3 (7-9.25)8"1'-3.5"2'-6"4'-0"25RISER MANIFOLDIFOW IFOWAC1'-5"1'-5"1'-6.5"1'-1"9"6"8" 1.5 10-0 1.5 4-8 1'-0"1'-0"8" BRANCHLINE4(3-11.5)4(0-2.5)4 (5-1.5)3 (0-4)3(0-7.5)3(1-1.5)3 (8-10)WET SYSTEM #4MEZZANINEWET SYSTEM #33RD FLOORWET SYSTEM #22ND FLOORWET SYSTEM #22ND FLOORWET SYSTEM #33RD FLOORWET SYSTEM #4MEZZANINEDRY SYSTEM #11ST FLOORSTANDPIPERISER4 (4-1)111111114(7-6)404040T T 4 (13-7)4(1-8)19194" BFY STANDPIPEISOLATION VALVESSP411'-0.5"STANDPIPE 1'-0"STANDPIPE1(0-4) U.N.O.1" TEE W/ PLUG1" ELBOW1.5" BRANCHLINEDRY PENDANTSPRINKLER HEADA = FIELD ORDERMETAL SOFFIT CEILING1" NIPPLE, F.O.6"1.5" x 1/2" 45° GALV ELL WITH1/2" SMOOTH BORE BUSHING1.5" BALL VALVE1.5" (0-3) SCH 40GALV NIPPLEHANG W/ (2) 3/8" x 2 5/8"KWIK BOLT & (2) 1.5" SPLIT RINGSUMP PITELEVATOR PITHORIZONTAL SIDEWALLWITH HEAD GUARDBOTTOM OF PIT2'-0" MAX ABOVE(2-0) 1 11-11PER PLAN(10-0) 1 (2) 1" SPLIT RING WITH 3/8"KWIK BOLT EZ-11" x 1" x 1/2" TEE1" BALL VALVE & PLUG(0-3) NIPPLE1.5" BRANCHLINE1" x 1/2" R.C.1" FIELD ORDER SSU1.5" BRANCHLINE48" EASY-FLEX, TYP.CHROME PENDENT SPRINKLER1" (0-2) NIPPLE1" 90° ELLRECEIVED11/19/2018 striplettBUILDING DIVISIONF18006376_V1ADD ONEADDITIONALINSPECTORTESTOUTLETNEAR THISLOCATION. ABOVE FINISHED FLOORBOTTOM OF TRUSSBOTTOM OF PURLINBOTTOM OF JOISTBOTTOM OF DECKBOTTOM OF BEAMINSIDE FACE OF WALLUNLESS NOTED OTHERWISENO AUTO. SPRINKLERSOUTSIDE FACE OF WALLABBREVIATIONSBOPCTSBOTOFOWNASIFOWUNOFOCUT TO SUITFIELD ORDERAFFBODBOJBOBHYDRAULIC CALCULATION NODEFLEXIBLE COUPLINGRIGID COUPLINGELEVATION ABOVE REFERENCED2-WAY EARTHQUAKE SWAY BRACE4-WAY EARTHQUAKE SWAY BRACECENTERLINE OF PIPE TO REFERENCEDLETTER INDICATES TYPELETTER INDICATES TYPESTRUCTURE IN INCHESHANGER LOCATIONPOINT IN FEET AND INCHESAABOD12SYMBOL LEGENDREVISIONSREASON FOR REVISIONNO.BYDATEKEY PLANHANGER LEGENDCERTIFICATE OF COMPETENCY STAMPSYMMANUFACTURERS.I.N.TYPEMODELSPRINKLERFINISHESCUTCHEONFINISHORIFICESIZETHREADSIZETEMP.RATINGQUANTITYSPRINKLER LEGENDTOTAL THIS SHEETOFFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.OFPROJECT MGRFAX: ( 253 ) 926 - 2350CONTR. REG. NO. SMITHFS1360TTACOMA, WA 984241106 54th AVE EASTSMITH FIRE SYSTEMS, INC.Bus: ( 253 ) 926 - 1880DATEDESIGNERSHEETJOB NO.PROJECT MGRTC18111THE STOR-HOUSEPHASE IV2829 NE 3RD STREETRENTON, WA 9805666M. MILLER11-16-18S. LAVINTHIRD FLOOR & MEZZANINE SPRINKLER PLANWASHINGTON STATECERTIFICATE OF COMPETENCYFIRE PROTECTION SPRINKLER SYSTEMSPhilip Stoehr7792-0213-C Level 3Smith Fire Systems, Inc.SMITHFS1360TSignatureExpires12/31/18Date11/16/18NMEZZANINE SPRINKLER PLAN1608SCALE 1/8"=1'-0"N3RD FLOOR SPRINKLER PLAN1608SCALE 1/8"=1'-0"RELIABLERA1425SSUF1FR56BRASS---5.6K1/2"155°360RELIABLERA1435HSWF1FR56BRASS---5.6K1/2"155°2370RELIABLERA1414REC'D SSPF1FR56CHRMCHRM5.6K1/2"155°8STUB-UP DETAIL 'D/6'DRY PENDENT DETAIL 'E/6'FITTER / LISTER NOTES1. BRANCHLINES ARE TO BE INSTALLED AT 5" BOD, UNO.2. MAINS ARE TO BE INSTALLED AT 14" BOD, UNO.3. ALL BRANCHLINE HANGERS ARE TO BE '3CP', UNO.4. ALL MAIN HANGERS ARE TO BE '6SB', UNO.5. RISER NIPPLES THIS LEVEL ARE TO BE GRV SN TO SN, UNO.6. DENOTES NON-COMBUSTIBLE BAFFLE, UNO.7. LATERAL BRACES CAN BE OMITTED AS PER NFPA #13, 2013 ED.SECTION 9.3.5.5.10 "THE (LATERAL BRACING) REQUIREMENTS...SHALL NOT APPLY TO PIPES INDIVIDUALLY SUPPORTED BYRODS LESS THAN 6 in. LONG MEASURED BETWEEN THE TOP OFTHE PIPE AND THE POINT OF ATTACHMENT TO THE BUILDINGSTRUCTURE.".FITTER / LISTER NOTES1. BRANCHLINES ARE TO BE INSTALLED AT 5" BOP, UNO.2. MAINS ARE TO BE INSTALLED AT 16" BOP, UNO.3. ALL BRANCHLINE HANGERS ARE TO BE '9SB', UNO.4. ALL MAIN HANGERS ARE TO BE '6SB', UNO.5. RISER NIPPLES THIS LEVEL ARE TO BE 1.5" (0-5), UNO.6. DENOTES NON-COMBUSTIBLE BAFFLE, UNO.7. LATERAL BRACES CAN BE OMITTED AS PER NFPA #13, 2013 ED.SECTION 9.3.5.5.10 "THE (LATERAL BRACING) REQUIREMENTS...SHALL NOT APPLY TO PIPES INDIVIDUALLY SUPPORTED BYRODS LESS THAN 6 in. LONG MEASURED BETWEEN THE TOP OFTHE PIPE AND THE POINT OF ATTACHMENT TO THE BUILDINGSTRUCTURE.".CONTRACT WITHPROJECT MANAGER :PHONE :FAX :SUPERINTENDENT :PHONE :FAX :COLVOS CONSTRUCTION711 COURT CTACOMA, WA 98402BRIAN NEAL253-844-4640JEFF BIRD253-355-2088DN DN 240'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"3'-0"5'-0"70'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"25ABCDEFGH2423222120191817161514131211109876543215'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"3'-0"5'-0"5'-0"3'-0"4'-6"8'-0"2'-0"2'-0"2'-6"2'-0"ELEV. # 1ELEV. # 29'-0" AFF1.510-1.5 SSSS1.58-11.54-0.51.510-1.5 SSSS1.58-11.54-0.51.510-1.5 SSSS1.58-11.54-0.51.510-1.5 SSSS1.58-11.54-0.5 1.5 10-1.5 SSSS1.5 8-1 1.5 4-0.5 1.5 10-1.5 SSSS1.5 8-1 1.5 4-0.5 1.5 10-1.5 SSSS1.5 8-1 1.5 4-0.5 1.5 10-1.5 SSS1.5 4-0.5 1.5 10-1.5 SS1.5 4-7 SSSS1.5 6-4 1.5 5-1 1.5 4-7 1.5 7-8 SSSS1.5 6-4 1.5 5-1 1.5 4-7 1.5 7-8 SSSS1.5 6-4 1.5 5-1 1.5 4-7 1.5 7-8 SSSS1.5 6-4 1.5 5-1 1.5 4-7 1.5 7-8 SSSS1.5 6-4 1.5 5-1 1.5 4-7 1.5 7-8 SSSS1.5 6-4 1.5 5-1 1.5 4-7 1.5 7-8 SSSS1.5 6-4 1.5 5-1 1.5 1-2 1.5 7-8 SSSS1.5 6-4 1.5 5-1 1.5 1-7.5 1.5 1-2 1.5 1-2 1.5 1-2 1.5 1-2 1.5 1-2 1.5 1-2 1.5 1-2 1.5 1-2 1.5 1-2 1.51-21.51-21.51-2 1.5 6-7 1.5 1-0 1.5 6-4 1.5 1-8 16-516-5SPT PT 1.5 4-3 1.5 2-0 SSSCONTINUED ON MEZZANINE PLAN 1.510-01.54-31.52-0 SSCONTINUED ONMEZZANINE PLAN5BOP 5BOP5BOP5BOP31-91.5 7-6 1.5 1-10 1.5 4-8 1.5 6-71.5 1-0 1.5 1-3 SSS1.5 4-0 1.5 1-3 1.54-11 1.51-0 1.54-1 1.56-10 1.5 5-9 1.5 1-0 1.5 1-2 1.5 5-9 1.5 1-7.5 1.5 5-9 1.5 1-0 1.5 5-9 1.5 1-0 1.5 1-7.5 1.5 5-9 1.5 1-0 1.5 1-7.5 1.5 5-9 1.5 1-0 1.5 1-7.5 1.5 5-9 1.5 1-0 1.5 1-7.5 1.5 5-9 1.5 1-0 1.5 4-6 1.5 8-61.52-61.5 4-0 SSSSS1.5 1-7.5 1.5 1-0 1.5 1-7.5 1.5 1-0 1.5 1-7.5 1.5 1-0 1.5 1-7.5 1.5 1-0 1.5 1-7.5 1.5 1-0 1.51-7.51.51-01.51-7.51.51-01.51-7.51.51-01.51-7.51.51-01.54-61.54-61.54-61.54-6 1.5 4-6 1.5 4-6 1.5 4-6 1.5 4-6 1.5 4-6 1.5 4-6 1.5 7-6 1.5 1-7.5 1.5 1-7.5 1.5 5-0 1.5 1-0 1.5 1-0 1.5 5-0 1.5 1-11 1.5 1-0 1.5 1-0 1.5 4-3 1.5 8-0 1.5 6-2 1.5 4-3 1.5 5-3 1.51-01.5 7-10 1.5 2-0 1.5 6-0 1.5 8-0 1.5 1-8 1.5 6-10 1.5 10-0 1.52-6SSSSSSSSSS35-01.5 1-0 310-038-7310-0310-037-5310-036-737-632-637-6310-034-7310-038-7310-0310-037-535-931-932-632-637-634-632-8 1.56-61.51-01.54-8 1.51-0 SSSSSSS1.57-101.52-01.57-61.56-91.510-0 1.56-10 1.51-5 1.52-6SSSSS32-71.51-231-535-51.5 1-0 1.5 1-0 32-633-532-71.5 1-2 31-51.5 10-035-68'-0"AFF7'-9"AFF10'-0"AFF 10'-0" AFF 10'-0" AFF 3(1-6.5)3(1 - 3 . 5 )35-939-530-720HYDRAULICALLY MOST DEMANDING AREA: WET SYSTEM NO. 4SYSTEM DEMAIND AT BASE OF RISER: 338.9 GPM @ 83.6 PSIINCLUDING (0) GPM FOR INSIDE HOSE ALLOWANCE332-046512871.5" R.N.(FIELDORDER,TYP.)1.5" R.N.(FIELDORDER,TYP.)1.5 1-7.5 4014024034044054064071.52-64084094104114124134144154164164171.5 4-7DETAIL E/65445 5 5 5 5 664UPDNUPDNELEV. # 1ELEV. # 2240'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"3'-0"5'-0"70'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"25ABCDEFGH2423222120191817161514131211109876543215'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"4'-4"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"5'-0"3'-0"5'-0"5'-0"3'-0"4'-6"8'-0"2'-0"2'-0"2'-6"0'-8"2'-0"1.52-7.5 1.58-01.55-101.56-01.52-01.52-01.58-0 1.52-7 1.53-6 1.57-6 1.54-0 1.54-0 1.57-0 1.52-7.5 1.58-01.55-101.56-01.52-01.58-0 1.52-7 1.53-6 1.57-6 1.54-0 1.54-0 1.57-0 1.52-7.5 1.58-01.55-101.56-01.52-01.58-0 1.52-7.5 1.53-6 1.57-6 1.510-0 1.53-3 1.53-9SSSSSS SSSSSS1.52-7.5 1.58-01.55-101.56-01.52-01.58-0 1.52-7.5 1.53-6 1.57-6 1.510-0 1.53-3 1.53-9SS SS1.52-7.5 1.58-01.55-101.56-01.52-01.58-0 1.52-7.5 1.53-6 1.57-6 1.510-0 1.53-3 1.53-9SS SS1.5 2-7.5 1.5 8-0 1.5 8-0 1.5 2-7.5 1.5 3-6 1.5 7-6 SSSS1.5 2-7.5 1.5 8-0 1.5 8-0 1.5 2-7.5 1.5 3-6 1.5 7-6 SSSS1.5 2-7.5 1.5 8-0 1.5 8-0 1.5 2-7.5 1.5 3-6 1.5 7-6 SSSS1.5 2-7.5 1.5 8-0 1.5 8-0 1.5 2-7.5 1.5 3-6 1.5 7-6 SSSS1.5 2-7.5 1.5 8-0 1.5 5-10 1.5 6-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 1.5 4-0 1.5 7-0 SSSS1.5 2-7.5 1.5 8-0 1.5 5-10 1.5 6-0 1.5 2-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 1.5 4-0 1.5 7-0 SSSS1.5 2-7.5 1.5 8-0 1.5 6-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 1.5 4-0 1.5 7-0 SSSS1.5 2-7.5 1.5 8-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 SSSS1.5 2-7.5 1.5 8-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 SSSS1.5 2-7.5 1.5 8-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 SSSS1.5 2-7.5 1.5 8-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 SSSSS1.5 2-7.5 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 1.5 4-0 1.5 7-0 SSSSPT110-01.5 6-7 1.5 0-6 1.5 2-7.5 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 1.5 4-0 1.5 7-0 SSSSPT 1.5 6-7 1.5 0-6110-01.5 5-6 1.5 8-0 1.5 2-6 1.5 2-6 1.5 8-0 1.5 5-6 1.5 5-6 1.5 3-3 1.5 4-9 1.5 8-6 1.5 5-6 1.5 3-3 1.5 8-6 1.5 4-9 1.5 8-6 1.5 4-9 1.5 3-3 1.5 5-632-631-636-01.5 4-0 1.5 1-10 1.5 4-0 1.5 1-10 1.5 6-0 1 5-4 1.5 2-0 1.5 1-6 1.5 1-6 1.5 3-6 1.5 1-103 5-0 1.5 2-0 1.5 3-4 1.5 3-4 1.5 3-6 1.5 3-6 1.5 2-0 1.5 3-6 1.5 3-4 1.5 3-4 1.5 3-6 1.5 2-0 1.5 3-4 1.5 3-6 1.5 2-0 1.5 8-6 1.5 4-9 1.5 3-3 1.5 5-6 1.5 3-4 1.5 3-6 1.5 2-0 1.5 5-6 1.5 8-0 1.5 2-6 1.5 2-6 1.5 8-0 1.5 5-6 1.5 2-0 1.5 3-4 1 5-4 1.5 3-0 1.5 1-0 1.5 1-0 1.5 1-0 1.5 1-0 1.5 1-0 1.5 4-01.52-61.5 5-0 1.5 2-0 1.5 2-0 1.5 8-0 1.5 2-7 1.5 3-6 1.5 7-6 1.5 4-0 SS1.5 2-0 1.5 2-0 1.5 8-0 1.5 2-7 SS1.5 3-6 1.5 2-0 1.5 7-6 16-01.5 3-0 1.5 1-0 1.5 3-6 1.5 7-0 1.5 2-0 1.5 5-0 1.5 8-0 1.5 2-7 SS1.5 7-0 1.5 6-1 1.5 7-6 1.5 3-7 1.5 6-5 1.5 10-0 1.5 1-5.5 22-01.5 7-6 1.5 7-0 1.5 2-0 SSSSPT 1.5 3-6 1.5 2-0 1.54-016-61.5 2-7.5 S1.5 6-7 S1.5 3-4 1.5 2-10.5 1.5 5-6 3 1-0 3 3-0 3 2-6 3 12-0 3 3-6 3 5-6 1.58-0 1.52-7 1.53-6SS 1.52-05BOP 5BOP5BOP5BOP5BOD5BOD5BOD5BOD1.52-61.56-7 S1.55-6 15-01.53-6 1.512-0 1.51-6 1.52-7.51.53-4 S1.510-6 1.57-61.510-01.55-111.52-11.57-0SS PTPT 1.510-01.54-41.53-01.57-0 1.56-1 1.57-6 1.53-7 1.56-5 1.57-0SSS SS9'-0" AFF1.5 12-6 17-61.5 0-8 CONTINUED ON MEZZANINE PLAN CONTINUED ONMEZZANINE PLAN 1.50-817-635-437-635-0310-036-833-4310-0310-039-4310-034-831-630-833-636-634-435-837-632-632-61.5 2-035-1031-8310-0310-01.5 2-032-41.5 2-037-8310-036-433-8310-039-41.52-030-837-635-037-633-83" UP TO MEZZANINE, SEE DETAIL'D/4' ON SHEET 4 OF 6, U.N.O.324-4 324-4314-4312-103" B/B 90° ELL38-5.50'-6"SEE DETAIL 'C/4' ON SHEET 4 OF 6, U.N.O.2030HYDRAULICALLY MOST DEMANDING AREA: WET SYSTEM NO. 3SYSTEM DEMAIND AT BASE OF RISER: 431.7 GPM @ 115.8 PSIINCLUDING (0) GPM FOR INSIDE HOSE ALLOWANCE345678103013023033043053063073083093113103123133143163171.5 3-6 1.5 3-6315 T311T3121.5" (0-4)R.N.,TYP.1.5" (0-4)R.N.,TYP.T310122(9 - 0 )24-11.5(8-11)1.5(8-11)1.5(8-11)1.5(8-11)1.5(9-0)TYP.TYP.TYP.TYP.DETAIL E/6DETAILD/6222 2 2 2 2 22 2 22 2211122 2 3331.5" BRANCHLINE1" x 1/2" R.C.1"FIELD ORDER SSU1.5" BRANCHLINE48" EASY-FLEX, TYP.CHROME PENDENT SPRINKLER1" (0-2) NIPPLE1" 90° ELLRECEIVED11/19/2018 striplettBUILDING DIVISIONF18006376_V1