HomeMy WebLinkAboutTRO4101424.1mis �wTaacT _
A Sp/ric Ar t
eoo/
=YIS7XIVI S )=A/VEL
,�v �vvr.�oJ% .svc�� /�•4W�`L �h�EUULE
NO.
LGii4T/ON STEI/FiY5 �. SVYcS S.W. 5TH CT G' O/�G� kVZ1: ' / / hA5_5 _3T W/RE
L .
SEY7V IA49 .�4.o w.14f MA/N CIA"Z . /T BR1 AfCR_ R
0YT
&V 0 O�/F'Tr0A1
J1rV 4
TR/P Ti4/P
N!/r9
LL34O Gi�SCR/A'T/O/V
CffT
A42
AMPS AMr=S
20 20
NO.
ST_ 1/6f/1✓' /, 2, 3, 9, 5
/.:
/. !
ST. L/G/HlS 6, 9. 8, 9
2
9
-4
20 20
//
ST. L/6H1,S? /g 15/6,/1411
6
9
.S1"L1GGh�7518.19 W. 21.. 22, 2-3,�
/. /
20 n-
S�IC� O/YL
/o
15
CD/l/Ti4AGTOf? CD�/,9r t�TpCELG
O. 5
20
O. 5
L/T/L/TY R£G'EF>Ti�iC1_E
A97
• STREET LIGHT - 150 WATT HIGH PRESSURE SODIUM, 240 VOLTS,
MEDIUM/NON-CUTOFF/TYPE 3 DISTRIBUTION (FIELD ADJUSTABLE),
POWER DOOR TYPE CONSTRUCTION, DROP LENS,
PROVIDE 25 FOOT, TAPERED ALUMINUM, DAVIT TYPE POLE PER
CITY OF RENTON STANDARD,
G "a
UNDERGROUND CONDUIT 1 2" CONDUIT WITH 2 #8 CU THW
CONDUCTORS & 1 #8 COPPER GROUND.
STREET LIGHTING JUNCTION BOX SEE DETAIL, THIS SHEET.
PUGET POWER VAULT & STREET LIGHTING TRANSFORMER SEE ONE-
A11A LINE RISER DIAGRAM,
C� STREET LIGHTING CONTROL PANEL 'SL' SEE DETAIL, THIS SHEET.
O STREET LIGHT REFERENCE NUMBER PROVIDE STANDARD WATTAGE
DENTIFICATION DECALS FOR EACH LUMINAIRE (I.E. '15'
DESIGNATES 150 WATT LAMP.)
TYPICAL LIGHTING UNDERGROUND SYSTEM
TO LUMINAIRE
TYPICAL DESIGN *8'
JUNCTION 80
FUSE KITS
OUR:K DISCONNECT
�PL10E KITS ''`
TOP OF CONCRETE
to AMP IN LINE FUSE
FOUNDATION TO BE
CLEAR EPDXY SPLICE- KITS-S.E.C. OR EQUAL
LEVEL WITH- TOP
KITS ON ALL THRU
OF SIDEWALK OR
WIRE RUNS, GROUND LUG
CURB.
I MIN. GROUT PAO
ra 1/4"MiN.
UNDER POLE BASS .,
-- DRAIN HOLE
2-(SIZED AS ''
II
REQUIRED) !i
is
p
LIGHTING
GROUND
II
SYSTEM WI
;L
CLAMP
II
I
TO CONTAC_ .i
II
it
TOR
PVC
II
CONDUIT
11
I
SYSTEM-)
11
II
It
11
PVC CONDUIT II 11
SYSTEM CONCRETE
L� cJ
FOUNDATION
I _- 3�-SO. OR R0.___ J
(-5-,r a 8' ON 4' DEPTH FOR POLE HEIGHT
COPPER -CLAD GREATER THAN 30'•
GROUND R00 3'OEPTH FOR POLE HEIGHT
30' "OR LESS.
Sized as required fN.Ra.
/su►rrcTn —
�a
\\\\\\\ 4 yr as
'.'.� `.In TALL eRACK[T
\ ALUM, ALLOT aosa-Ta
aRC LOCI1a OLT
U-a 1a.
R\�FLUSN JOINT
`. yr as
r4rca[D eLur. .oLc
Ip :ALL ALLOY foe]-Ta
�]ATIr GROUND FI NIaN
]HAFT
lee
1 i TO 12"
BOLT c1Re[
(4) 1' ■NC GALV. ]TL
♦ 1/2* OFl901.T
ACHOR eoLT] r14N
eOVE FINISHED
NURTO AND WASHER1�
���AAA
J �AO[.
8'0.a t]I HANIONOLS
♦'. A' OPENING
�r/COVER AND
GROUND LUGs.
1 a'd
1 e' aA][ F ALLOY
WITH
3e-TO NITN BOLT
7
STANDARD 25' DAVIT
POLE
1424
s/16'
COVE
TYPICAL LIGHT BASE AND JUNCTION 80X
LOCATION
TYP. GONG. PAD R/W LINE
SIDEWALK
CURB
i W
— — ROWY. I[
I >
1
I V\
CURB
SIDEWALK
R/W LINE
TYPICAL PLAN VIEW
I
TAPERED ALUM. POLE
.I WALL ALLOT G063-Ili
AS
SATIN GROUND FINISH
HANDHOLE 4'a G'
OPENING w/ COVER m 2'I04
S.S. SCREWS.
;round lug
Inside Pala
I Trench lac
Rat to scale
TYPICAL. STREET CROSS SECTION
JUNCTION BOX - DESIGN -e
i
GALV STEEL
R PLATE �_ PRO
^?IO PATTERN)
i I I
416 GALV 'WELDED WIRE LOOP
GALV. STEEL FRAME ANCHORED IN PLACE
(DIAMOND PATTERN)
mi�
7;_'�
SECTION A -A lr
SECTION 9-9
Note:
Contractor should be aware
that when changing existing
panel to add circuits of this
contract, care should be taken
to place breakers in a position
where existing wiring will
make connections without
splicing.
�- SEE NOTE 2
e IV /Vo.
�X 1 orx�'EXrsf G'or�tia/
Fb/71f!_�/
A = EX/ST/NG ✓UNCT/ON BOXES
ON 5X1571 I %ZO C01YDU/7
\ SEE NOTE 4
—c A
r
-0� /F
a� 4
lol6c �1�
GENERAL NOTE
Work
provided and performed
on this plan shall be accomplished in
accordance
with the State of
Washington Standard
Specifications for
Road
and Bridge Construction,
latest edition.
When
conflicts occur between
these plans and the
Standard Specifications,
these
plans shall prevail.
' SC
LUM/NA/R,E
STATION
S/l7�
/i,��
25 - Coe. 47 I
RT•
6.2 c_ 1
`°19
27 - OS . /O
L 7.
6.2
25'-C�
il9 h'
*�
28 ¢7. 72
RT
�28G
21
29 1490. 35
GT.
G2
Z2
31 - .30. 97
RT.
6 30 0-
1?5
9f76 .55';E
24
8 t 2G , 55
LT.
N4,P0/E AI/ENUE S.W.. STAT101Y1,W
4*C0* may
4*4 ?hi:r
7 aftd 0,6c .
II 11�oles z3 �' e4 Or//y
� ✓-Box o�` F'o/C use
Corrcref�' Sic�wo%�
SFCTICW LOGL</NG 11OR771
.4AClYLLE $W ITS
Exrs�`ii-�g
SeB/V nZ No. >c� �
1 Xi
S,�CT/ON t"OOfC/NG� WEST
OW
S.W 67Y7 1=LACe
v�
1L/rt Z'/�/)e��
/v1T 57r7_16
N%,�
7
1 7�_�
APPROVED BY ���t� � /� �/�9/gZ
tablic Works Di7ector
s��ci��clarioiv� � ivoT,�s
Power source shall be from an existing street lighting control panel at
Stevens Place S.W. and S.W. 5th Court.
2. Add one (1) 20 AMP, 240 V breaker to the existing panel and identify and
label, "Circuit 7". Note: The actual load connection shall be initiated
by the contractor in coordination with PSP&L. Contact CHG prior to
installation.
Connect 2 - #8 THW copper conductors to the load side of the breakers.
Connect a #8 copper ground to the ground buss and pull the three wires
into the 1-112" existing conduit containing 4 #8 and 1 #8 ground wires.
This conduit will be the one connecting to the existing pole #9 and then
to pole 4 at Maple Avenue S.W.
4. Intercept the existing conduit between poles 4 and 5, at a point closest
to pole 4. (See Drawing El of Cross Engineers) Cut the conduit, and
after disconnecting wiring in pole #4 base, pull wiring back to "cut"
location and install two factory "L's". Install a Type "B" junction box
at this location as shown on the plans as J.B. #1. From this junction
box also install a 1-1/2" conduit to the existing Maple Avenue S.W.
crossing, and J.B. #2 (to be installed by this contract) as shown on the
plans. The three #8 wires brought from the "street lighting control
panel" (note 1 above) will now enter this contract's conduit system and
be installed according to plans to the termination pole (24) located on
Hardie Avenue. See Note 16 below.
5. All disconnections at pole 4 (note 4 above) shall be connected
immediately so that the existing lighting system will function without
interruption.
6. Conduit shall be 1-1/2" PVC schedule 40 except for street crossing which
will be 1-1/2" galvanized steel. Crossings shall be jacked, pushed or by
gopher.
7. Street Light - 150 W., H.P. sodium, 240 volts, medium non-cutoff/Type III
distribution (field adjustable), power door type construction, drop lens
type. Y
8. Provide 25', tapered aluminum, davit type poles per City of Renton
Standard.
9. Contractor is cautioned to use care in trenching as PSP&L underground is
in the same vicinity as shown on the plans. PSP&L is 36" + or - under
ground and this contract calls for 24" cover. The Maple Avenue crossing
location is approximate as are all conduit details as shown on plans.
All utility work involved should be coordinated by the contractor with
PSP&L and PNWB before trenching, pushing or pole base excavation is
initiated.
1<<. Junction boxes shall be Type "B". See City of Renton Standard.
11. Poles shall have 8' mast arms.
12. Locate pole bases at sidewalk per details.
4
7 142
13. Street Light Reference Numbers: Provide standard wattage identification
decals for each luminaire (i.e., 15' designates 150 watt lamp).
14. Pole I.J. numbers shall be installed as shown on the plans and
shall be approximately 121 above curb. ?Atters and,rumber
shall be 31' hiGh and apnliec? as ��Pather_-ror'?f; ref??rtive
decals as approved by the C�-ty of Renton.
15. Locations shall be staked in field by Engineer.
16. At contractor's option, in lieu of pulling 2 #8's in existing
conduit, may install a new 1-1/2" PVC, Schedule 40 conduit
behind S/W from J-box #1 to control panel for connecting
luminaires #18 thru #24 to service per note 2, above. If this
option selected, an intermediate pull box will be required and
a #8 groundwire. /�7u
Pl__,,C ;oncrete pads, 1211 perimeter by 11 uee-c wlL I. Cla:- :
surface finish around all, J_boxes. See typical light base
and junction
Q
�I
Zzl,
O
w
LLJ
CCY,,
�
LL
=
U
Q
U
�
Z
Q
V
o -
-�
co
__ (A
—
L i
N
— —k"_
_
_r\
0-
=moo
- _
C:__�
-�_J)
�- t
_
C
C=M-GJ
LLJ=Q�=�
19i
SHEET
1 of
a7
JOB N0.2/4VV. 49