Loading...
HomeMy WebLinkAboutTED4001755.2EX. BLD(' 4-01 v 2 O U EX. CB RIM = 19.2C w EX. N = 17.34 NEW S.W. INV = 17.34 CO O €MEET VVI\VRET€ PAVEME,NT EX . BLDG 4.03 EX. F. H. I CONCRETE IW7 10 WATER li y MONITORING Nit, ; a32 WELL 0 3 00 N o;tom �A `( Z v 'lr sp p 0 hh�� I 3 r ZC�O �(1% II r 4 C.O. TOP = 20.00 (FLUSHED TO EXISTING PAVEMENT) INV=18.00 I 3' CONCRETE ASHPHALT A I LEGEND pa WATER VALVE TELEPHONE MH ---- TO O BOLLARDS SANITARY SEWER MH OS FIRE HYDRANT SPRINKLER CONTROL VALVE P4SPK 0 FIRE STAND PIPE SURFACE/STORM WATER MH (g ❑V POWER VAULT CLEANOUT - OCO. OW MONITORING WELL CATCH BASIN -- ❑ CBt3 -28 EXISTING GROUND ELEVATION I - 10"x 6" TAPPING TEE, MJttFI - 6" TAPPING VALVE CR*M3) Wt hvt tNVitATqR THRUST BLOCK AREA .UNDER TRENCH TO BE HAND EXCAVATED do BACKFILLED WITH LEAN CONCRETE r EX. BLDG 4-81 EXISTING PAVEMENT -H I t ( I I I EXISTING UTILITY TRENCH I RIGID PAVEMENT WITH ASPHALT CONCRETE SURFACE ASPHALT CONCRETE OR BITUMINOUS / PLANT MIX PAVEMENT REPLACEMENT PATCH -- CUT WITH PNEUMATIC PAVEMENT CUTTER - CUT SHALL BE VERTICAL AND IN STRAIGHT LINES z / AS DIRECTED EXISITNG ASPHALT THICKNESS OF EXISTING PAYMENT --- ---- N PAVEMENT PLUS x2m EXISTING CONCRETE PAVEMENT EXISTING RIGID j BASE 60 D.I. SEWER 12" MIN WHERE PATCH IS 4' NOTIFY BOEING OR MORE IN WIDTH- CONSIRUGT10N ENGR. IF 12 MINIMUM CANNOT BE MET. 6 •' SEWER COMPACTED TRENCH MAY HAVE TO BE BACKFILL AS DIRECTED /� LOWERED. BY THE ENGINEER UTILITY TRENCH -CROSSING SCALE: 1 /2" - 1•-0- G.D. APPROX. 20.3 EXISTING STANDARD STD. LADDER PRECAST CONE \//- RUNGS - �T y 1. INTERCEPTED 4910" 4 Z DUCTILE IRON PIPE TO UNDISTURBED SOILNof DUCTILE IRON I I PLUG MJtOTH ITH I / TEE MJxMJxMJ I GASKET C ASHPHALTJ / x / I IN HALF. I n W, 1I I ' EX. iI i ,"1 I E 14.0 .I „ I _y I E 13.50 BLDG EX h sLOTTE IN INCO IN E LINE 4.02 I (ABA ED) I 6 I. WER / V NDI C814 1 EXISTING MH WALL I - • 010 o TILE IRON PIPE II • TO BE BROKEN I EX.FH 3 I I THROUGH AT THESE 5 c.o. To = Is. • LASS 50 CEMENT I POINTS. SEE NOTE TOP= 20. BOL 0 1 LINED. LENGTH TO FIT - \ PROVIDE C.O. BOL� I.E=10.20 - / � ELEC L .o �� COND E \ �.,, I CONCRETE ENCASED -� `- \ \ I (4 SEWER LIFT STATION \ � � it •� � � C.O. E NOTE 4) DUCTILE IRON 900 I r \ INV =15.5 " I T F= 2 .2 RIM 19.70 6 BEND MJ X PE - i 0 0 G // ! e IE 17.05 „ ON t41/�• e HPw Ex.ce 1 ` CONC. BLOCKING CEM. CONC., m CLASS B (I I /2) 10" HPW � ,�. , � EXISTING SEWER MANHOLE CONNECTION RIM = G .06 C/ COMM ACCESS I NTS I E = I EX 8CEI /� / DOOR ASHPHALT%1 CONCRETE f j I o ASHPHALT / I a 9�A cy c y r-- EX SSMH � } RIM 22.76 ZG O I / ui EX. INV (S) 14.00 (8 '), 1 EX. INV (E) 10.00 (6�) 8 w NEW IN (N) 13.50 (6) a DROP STRUCTURE) J O Z BOTTOM INV = 10.20 SEE DETAIL THIS SHEET 0\ \ I I I O / L / 3 o\ COMM ACCESS v O DOOR =cp 0 VAULT N p l 0 '\ / - BOLLARD I SS MHis.. O / S -.1 ,4�FORCE MAIN (SEWAGE) s STEAM I I BO- EXISTING SEWAGE 11 \ J/ �I EX. 8�� MM LIFT STATION CW (DOMESTIC) CONNECT TO EXISTING 8'' WATER 1- 8" x g" x 2 TAPPI^.G TEE MJ x FIL BENCHMARK r _ / �._ / EX. BLDG 4 17 j / EXISTING SEWER LIFT 76 12 TAI FI^JG VALVE FL x PE BOX & Cl7VE!1 STATION RIM = E2 = 22 BLDG No. 4 17 POST TOR I VAL OVIDE WITH FF EL= 22.25 T OREC SWITCH Y ADT NOTE 9)I I �zilb Q 41' 30,- 6" D.I / �- \9 ESPRINKLER SYSTEM r p 6 450BEND j 0 fo THRUST BLO I I ~ 0h PROPOSE / I CONCRETE'. \ // 20.67 I C.O. Z,0 6 90 VERTICAL BEND I SPK g THRUST BLOCK VERTICAL PIPE TO BE r / INSULATED I SEE NOTE 3 / WV k,77 70 ti L ® ; of I i PLAN OF UTILITIES AT BUILDING NO. 7-'404 ( PROPOSED) SCALE I"= 20'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE - 1- DROP I SA& SE GENERAL SPECIFICATIONS: 1. EXISTING CONDITIONS AND EQUIPMENT LOCATIONS SHOWN WERE LOCATED FROM EXISTING INFORMATION AVAILABLE AND FIELD MEASUREMENTS. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS PRIOR TO START OF ANY WORK. 2. DUCTILE IRON PIPE SHALL CONFORM TO ANSI A 21.51 OR AWWA C 151 AND SHALL BE CEMENT LINED, PUSH -ON OR MECHANICAL JOINT. THE DUCTILE IRON PIPE SHALL BE CLASS 50. JOINTS SHALL BE RUBBER GASKETED CONFORMING TO THE REQUIREMENTS OF ANSI A 21.11 OR AWWI C. 111. 3. BACKFILL MATERIAL FOR NEW CATCH BASIN INLET AND PIPES SHALL BE NONCLAY MATERIAL CONTAINING NO PIECES MORE THAN 3 INCHES ACROSS, NO FROZEN LUMPS, AND NO WOOD OR OTHER FOREIGN MATERIAL THE BOEING CONSTRUCTION ENGINEER MAY ORDER THE CONTRACTOR TO USE LEAN CONCRETE IN BACKFILLING AROUND THE NEW INLET AND PIPES. BOEING WILL PAY FOR SUCH BACKFIWNG. 4. FOR CONNECTION TO EXISTING SEWER MANHOLE, THE MANHOLE SHALL BE CORE DRILLED. A CONICAL TYPE FLEXIBLE SEAL EQUAL TO KOR-N-SEAL SHALL BE INSTALLED. 5. THE CONTRACTOR SHALL PRESSURE TEST ALL WATER LINES IN ACCORDANCE WITH SECTION 7-11.3(11) OF THE CITY OF REIvTVN STANDARD SUPPLEMENTAL SPECIFICATIONS. ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 BOE/A/G ❑ KENT, WA. 98031 FACILITIES DEPARTMENT E� PORTLAND, OR. 97 220 ■ KENTON, WA. 98055 ❑ SEATTLE, WA. 98124 PIPE BEDDING FOR 6 D.1. PIPE NTS WHERE WIDTH OF PATCH IS LESS THAN 4' COMPACTED SELECT MATERIALS AS DIRECTED BY THE ENGINEER 60 1 6- 1 12- 1 VARIABLE 11201 60 1 ® - TYPICAL PATCH FOR RIGID PAVEMENT NTS PEA GRAVEL BEDDING 2"+ CRUSHED GRAVEL FOUNDATION 110 0 CLEAR OPENING LAMPHOLE COVER EQUAL TO OLYMPIC FOUNDRY 2' - 6' CO. NO. 5931 SQUi ARE 7, PAVEMENT N a r•- v - -SECTION 120 0 PIPE CONCRETE 12- LONG FIBER JOINT PACKING APPROVED WATERTIGHT PLUG OR CAP AT END - 6" SEWER PIPE ---BEND TO FIT PLUG -TO BE SEALED - IN SAME MANNER AS MAIN SEWER JOINTS. 6" SEWER PIPE 6" SURFACE CLEANOUT NTS RECOMMENDED FOR APPROVAL BY ' STORM W*TER VTluTy RECOMMENDED FOR APPROVAL 6. PAVING CONCRETE SHALL HAVE A MODULUS OF RUPUTURE OF 600 PSI WgsTE WIVrER vT1W-17 (MIN.) O 28 DAYS. RECOMMENDED 7. PRIOR TO ACCEPTANCE BY BOEING, THE CONTRACTOR SHALL PERFORM FOR APPROVAL A LOW PRESSURE AIR TEST OF THE SANITARY SEWER LINE. THE AIR BY 9��2 TEST SHALL BE IN ACCORDANCE NTH THE SHEET 5.3.1-A OF THE CITY OF RENTON. DPW. wA Ek VT(L41y 8. ALI- U 11'M � J�" Lt-117 I N 74-:r 1m FFZ07' 1 _-fl RECOMMENDED NOTES: FOR APPROVAL 1. THE PROPOSED STRUCTURE WILL NOT SUBSTANTIALLY ALTER THE DRAINAGE PATTERN, INCREASE THE PEAK DISCHARGE AND CAUSE F11e PREV6mrt0A1 ANY OTHER ADVERSE EFFECTS IN THE DRAINAGE AREA. 2. ROOF DRAINAGE FROM THE PROPOSED STRUCTURE TO BE O"OFRw�a+ TIGHTLINED TO EXISTING CATCH BASIN p E C E 1 V E D 3. EXPOSED WATER A SEWER LINES TO BE INSULATED JAN 3 (1 1991 BY THE TRAILER SUPPLIER. 4. PROPOSED UTILITIES CROSS A 13.8 KVA ELECTRICAL w JOHN R. EWING AND ASSOCIATES TRENCH. MAINTAIN MINIMUM 12" VERTICAL CIVIL ENGINEERING - LAND SURVEYORS AND 2' HORIZONTAL CLEARANCE WITH THE 1314 S. CENTRAL AVE., SUITE 200 EXISTING TRENCH. KENT, WASHINGTON 9W32 ;04- (205) 852-6633 REJRE JOB NO. 1279-06 //-/10-90 DRAWN BY DATE SUBTITLE ACCEPTABILITY DW 11 15 90 LAST REVISION sYMB DA THIS DESIGN ANDIOR CHECKED SEWER AND WATER PLAN SHEET SPECIFICATION IS APPROVED P. S. 11 15,90 10 APPROVED BY DEPT DATE ENGR lam. P S 1 1 15 90 TITLE r C - 1 OF S.,AIVNEp MAR 2 8 2003 CHECKED TRAILER COMPLEX 4 -17.2 JOB NO�Aft APPROVED "' APPROVED � � a �'^-� �� Z _r� DWG NO. A CHECKED FOR COMPLIANCE L Of S ANDARDS . - natp 2- Date I .•. td 5' O CD C 0 oCD N Ha O all tTj cr a' N