HomeMy WebLinkAboutTED4001760.1SAN_ SEWER M-H. i i A N N 296'SS BETWEEN MANHOLES - -- i i ' CATCH BASIN GR. EL.=26.40 I.E. 12:W=22.90 (EXIST.) I.E. 12(E)=22.70 I.E. 12"(S)=22.90 (NEW) CONTRACTOR TO VERIFY I.E- PRIOR TO CONST. BUILDING 61 27.5t 19' - 12" C. P ® 0.5 Zb i �26.74 C.B. No.2 TYPE I GR. EL =2415 8. 27.28 i 12'(w-E)=2j 5� 24.74 4 ROOF DRAIN=25.06 zee 77.6' - 8" D.I.-CL50 , 1.0% N ~ SAN. SEW. MH NOTE: MAINTAIN MINIMUM 5' SEPERATION RIM EL.=27.19 BETWEEN STORM AND SANITARY SEWER I.E. 8' =23.54 0 1�1 x l,. b, N O. % TYPE I GR. EL_ �6 (MATCH EX_ PVM'T.)27.14 I_E_ 12"(war- 24.52 > ALL TAPS ON EXIST_ SEWER) SHALL BE BY 90' TEE IBUILDING _ _ 0 10 i11 ALLEY BUILDING CLEANOUT RIM EL.=27-`5"27.92 - ' /_1L_ I_E =2A-14 MIN 25.52 (SEE SHT. 2 of FOR DETAIL X. MIN. EL.=28.13 BUILDING a . z I All x .'j E3 4„ PVC ROOF - I - - ---_ - 2' / DRAIN 1 vH,y YARD DRAIN No. 1 X1 BUILDING I +26.97 - - � - GR. EL.= 27.19 - - - - - - - ' 6 COA-C- . VAVLK- I E8"(E)=�25.52 (SEE IS SHT 'L6 MIN.+2596 CURB OPENING 6 +27.10 , 6.VERT CURB - 1 16. _. 24•SD t 1 - - f - - _ +27.�OX� T---_ 2 CONSTRUCT- _ ` i1 COMME 20' CO -�� � #2757 - 1� (SEE SHjIAL ORIVEWgy s> a _ .___-�-r _ qM� 6, cp k11 - - 2 o f 2 F l _ _ C2 ALK �1 OR DETAIL) _ CATCH BASIN #2 _ 3 _ REP OVE EX. LA DR1 RIM EL.=27 06 I.E- 8"(NW)=24.66 --------------------------- CHECKED FOR COMPLIANCE y T TANDARDS Date �- ----f ! . n Date STORM DRAIN MH _ = & VERT ECW1 rH RV W CUT RI 8L.w2628 61 - 1 _ _ 1�o NC CUR@ & PLANrER R ( )- o - =SECTION EPLACE GUTTER L E 24"(W)=19 69 ,,� _ Sf ON BRp N 1\a CTI KE �.E. 24"(N)=19 56 SIDEIALK i 1 T� A ilE. A. 1 V, 12' ALLEY .►\ 4 - PLEX F - - ---- ------ --- ------------------------------- --- - 8 13 - - _ - MIN. EL.-2 , ------------------ - - - -- - i EX PVM'T. I - CURB OPENING I� -- - - -- - f --- - _- _ _ - _ _ --- -- - - --- -------------- - -_ --- - - - -- - - -- - --- ------ - - - - --- - ---- - 8" DI.-CL50 ---------------- 1 -' - 0.60 % of 2 - - --1---------- - g1' - 12" C.P. - - - Ex. s-ss- - ------ ---- --- --- --- ------ Ex. e•SS 22' _ 6a IPVC CLEANOUT SEE SHT 2 / - - Ex. 12• CNP I I - - -- - YARD DRAIN No_ 1 7. L IL - - - -{ - 0 20% M N. RIM ELF F R CETA C.B. No.3, TYPE I C.B. No-2, TYPE I GR_ EL 14 7. 9 -25 52 ---------------i_ ----------- - -------------- ----- LE. 8"(E) 28-2552 - - - - Ex. L.E TYPE I GR. EL-=Y�(MATCH EX_ PVM'T-)27.14 GR. EL.=2.�-8fi-27.28 CONNECT TO EXIST SAN_ SEW. _I l_ _ (SEE DETAIL THIS SHT.) GR. EL.=26A0 -- I_E. 12 #AN=2�4-�1-23.42 - I �, 12'(w-E :, K 24.74 __ _ I E_ = 23.7t ---- - _ I.E. 12'(N)=22.90 - �-, 24.52 _ _ 4 ;ROOF_ - DRAIN=25.06 (W o _- CONTRACTOR TO VERIFY LE. 12'cE)=22J0 _ o - �� LOCATION & I.E. PRIOR � I LE 12"(S)=22 90 19' 12p C.P. • $`sf9% 1.12 /o r TO CONSTRUCTION - --- CONTRACTOR TO VERIFY I - - - - - ALL TAPS ON EXIST. SEWER I.E. PRIOR TO CONSTRUCTION . ----- - - --- -- } SHALL BC B" 90° TEE -- STORM DRAINAGE PROFILE SCALE: 1" = 20' HORZ. 1" = 5' VERT. SAN. SEW. PROFILE SCALE: 1" = 20' HORZ. 1" = 5' VE R T- - AS SURD NOTES.- 1. Yard Drain to be constructed from concrete IrI�� CAST IRON Pipe, in accordance with ASTM C 14 unless BELL GRATE otherwise shown on the plans or noted in the Standard Specifications. 2- Cutout hole size is equal to outlet pipe outside diameter plus area inlet wall thickness. 3 Connection to outlet pipe to be mortared and made flush with inside of the area inlet wall. 4. Cast iron bell grate shall meet the strength renuirements of Federal Specification RR-F-621D. The grate shall have slots (holes) that constitute 50% open area for drainage. Inlet bell surface shall be finished PLAN VIEW to assure non -rocking fit with any cover position. GR. EL.=27.14 `4 CONCRETE PIPE SECTION a) 8" CL50 D.I. o - C I-E-=25.58 z_ 18" MIN_ 4" MIN. CONCRETE CLASS B ELEVATION VIEW YARD DRAIN DETAIL N.T.S. MERIDIAN = ASSUMED BASIS OF BEARING: MONUMENTED CENTER LFNE OF WELLS AVE. N. (WELLS ST) DATUM = CITY OF RENTON BENCh MARK: CHISELED SQUARE IN BACK OF WALK AT THE INTERSECTION OF THE S.W. CORNER WILLIAMS AVE- N. AND N. 15th STREET ELEVATION = 27.89' LEGAL DESCRIPTION LOT 20, BLOCK 15, RENTON FARM PLAT #4, AS PER PLAT RECORDED IN VOLUME 13 OF PLATS, PAGE 90, RECORDS OF KING COUNTY, WASHINGTON. RECOMMENDED FOR APPROVAL BY �" "" 67/0 STORM WATER vnw ry RECOMMENDED 77 FO BY RECOMMENDED FOR APPROVAL BY TRAA/SPoRT,r-TI)y SysTEM5 / . i r/ LEGEND -SAN. SEWER MANHOLE -WATER METER -STORM MAN HOLE -STORM CATCH BASIN -POWER/UTILITY POLE j''�h-SPOT ELEVATION S- SET 1/2" DIA. REBAR WITH PLASTIC SURVE CAP LICENSE No's. 9634/10356 -FENCE Q qu lo--y-11 sArrn► L� LIAR 2 8 ZOGIL