Loading...
HomeMy WebLinkAboutTED4001770.1NOTES AND SPECIFICATIONS FOR STORM DRAINS 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, 1981 (APWA) AND CITY OF RENTON STANDARDS. 2. CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY SEDIMENTATION/COLLECTION FACILITIES TO INSURE THAT SEDIMENT LADEN WATER DOES NOT ENTER NATURAL DRAINAGE SYSTEM. THESE FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND CONSTRUCTION AND MUST BE MAINTAINED UNTIL CONSTRUCTION AND LANDSCAPING ARE COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLIG ALL CONSTRUCTION. 5. STORM SEWER PIPE SHALL -BE CONCRETE RUBBER GASKETED ASTM C-14, CL.2 OR ASTM C-76 II CORRUGATED METAL PIPE WITH GAUGE PER CHART SHOWN BELOW. STEEL OR ALUMINUM PIPE SHALL HAVE WATERTIGHT CONNECTING BANDS. STEEL PIPE SHALL RECEIVE ASPHALT COATING INSIDE AND OUTSIDE, TREATMENT 1 OR BETTER. CORRUGATED METAL PIPE SHALL HAVE TREATMENT 5 ASPHALT COATING WHERE SHOWN ON PLAN. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) PER ASTM D 3034 SDR 35 WITH A MINIMUM COVER OF 3 FEET. WATER MAIN PIPE SHALL BE DUCTILE IRON CLo52 WITH A MINIMUM COVER OF 3 FEET. ------2-2/3- INCH -BY-1/2-INCH -(NOMINAL)- CORRUGATIONS -------4 MINIMUM GAUGE GALVANIZED STEEL ALUMINUM 16 8" TO 48" 8" TO 27" 14 5411 30" TO 36" 12 60" TO 66" 42" TO 54" 10 7211 60" TO 72" 8 78" TO 96" 78" TO 84" CONTRACTOR NOTE: WHERE STORM DRAIN CROSSES EXISTING WATER MAIN & GAS MAIN FIELD, LOCATE EXIST- ING LINE PRIOR TO ANY CON- STRUCTION. EXCAVATE BY HAND ONLY WHEN WITHIN THREE FEET HORIZONTALLY OR VERT- ICALLY OF 20 INCH GAS MAIN. TOP OF PIPE_ 9.50 _____- INV. ELF_. 11.015 CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 Ttc,� _ �o - ♦»o 3 INCH BY 1 INCH CORRUGATIONS MINIMUM GAUGE GALVANIZED STEEL ALUMINUM 16 36" TO 102" 30" TO 60" 14 108" TO 114" 66" TO 72" 12 120" 78" TO 96" 6. BEDDING FOR STORM DRAIN PIPE SHALL BE CLASS "B" PER APWA STANDARD PLAN NO. 62 (PEA GRAVEL FROM 4 INCHES BELOW PIPE TO SPRINGLINE FOR PIPES 27 INCH AND SMALLER AND FROM 6 INCHES BELOW PIPE TO SPRINGLINE FOR PIPES 30 INCHES AND LARGER). 7. TRENCH WIDTH SHALL BE 40 INCH MINIMUM OR 1-1/2 TIMES THE PIPE DIAMETER PLUS 18 INCHES WHICHEVER IS GREATER. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN 6 INCH LAYERS COMPACTED TO 95 PERCENT OF MAXIMUM DENSITY. 8. TYPE 1 CATCH BASINS SHALL BE APWA STANDARD PLAN NO. 52, TYPE 1-C WITH APWA STANDARD PLAN NO. 49 FRAME AND GRATE AND TYPE 60 OUTLET TRAP. TYPE II CATCHBASINS SHALL BE APWA STANDARD PLAN NO. 55, TYPE II-C WITH THE SAME FRAME AND GRATE. 9. CONTRACTOR IS SOLEY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. NOTE Trap to be made of 22 Go. Galvan- ized sheet metal. All joints to be seamed and soldered. All longitudinal joints to be riveted. Dimension 'D' is nominal diameter of outlet pipe. 7" GOMFT. DEPTH GL. 5 ASFNA.LT GOr C. 4" U>4FT. DEFT GIZL15r�ED ROCIL o TDF GoU IC5E• <O o J 12" GOMFT, DEPT14 STIZUGTLIRAL. FILL CeSE coU It--> E . 0 _//JTO 95Y- MAX VeF-151Ty PAS• V I N G S E G 7 101�-1 D ITLN -TD 8E IMPROVED TO 0.5 % SLOPE / FOR ELEVATIO" "1.00 DISGHA TZGE A"T ( T 2 \ 7.88 3 6 1fJV•` ''� F TOPTyS� W OIL 15 25 RA70R \ •� \ INV. I-6-46) 12" N 1 N V. -H -(e g N g" 1 1. 2 ,as P�UIl-r Loc, INV. -a Qc- 5 IZ" 10.9 �f DQ �QIP RAP CS .R%/,e.L-V oE h� \ ?n IzO , x z � -- m Q < s � O 0 I \\ 0. m n x z 'p o W N �a o _ Z r X � y RL D6E L_lAlE'Z EX ISTINv N 10 14' 2 8" E 347.61' 14 O L. F. .- $•• I.0a 7. SANITARY SEWER �0 < e[ Type GOA Trap D. �4�• C-----� A „A„ o y' . \ D) ICE !� s L � ''-"'' - _ J o "• °°,.,� G GT G 1-1 Fj Gt i /-1 PLACE. OF FiLT69- FnEW-1 C• 62nJEL C3E1L �..� AQOJUD kAAT E.2I A V fN-_TwejE.•-1 FRn�.�E 'tkjo CGe.&TE:. PL A,1J 12" wioE 6Y d H�Gi4i. Gi ¢.oun.t r� �•• (LEPL pL.r. OPC>" F121-T --------- KE.Y �•J'To •SI . J OF �I !I FL cp-rcN Bos��-.I DETAIL -- SII..T C�►JTQOc.. @-G. P�.'S N 10 14' 28" E 271. 3& L VEe,161,1 lWF0IZMATVoL4 SEE C, RA tl l .,J , q D RAI AIACa E P L.A US VAL_L.Ey 405 SU51►.IE55 PAIL, SHEET I OF I Fulur-c- FIRt LESS C.S. TYPE I-G TOP 115. (PC)-15.51 NV.•i3. 9 5. B" 12.2 Sp O • 119.50) I (o 25' UTIL1Ty EASE ME N'T L.IJ O(') L 19 � Q LO 0/� cc) -� 1 iP SS. MAID NOL E REL.Oc A-rC- 16 xIS 4VVVAWT ►•IERE AS-BUILT 10 -8-86 �-- I '_J � I SCALE 1"=ZO' .EGEND _F,- RIDGE Ll►-AE 'l 9.5c IF X . G r-&r> E 1 !o - PROPOSED C OQTOU i-S I PRoPoSED SPOT GX_A. PES /?q0P 40P 150\ �O,�fJ'/ APPROVED FOR CONSTRUCTION S ANC. o w co CV o Z Q Esc CID 0 LJ Q �W V i W Cw Z> U� Q J o� v cn 0 cv 0 W W Wz O z crW J LL.I Lu > U Q � w O z Q7 o 0 CV N w I Y W JJ Z 0z Q 0 Z ~ U) LJJ O 0 x-�(.o Z _2 u��,o (D n z z O � 0 z Y W > WJ Q >- J W Q 0 > a. DRAWN BY CHECKED By PG RGG SCALE DATE T' = 2 0' 12 85 JOB NO 85161 .03 i CITY OF RENTON DEFT OF PUBLIC WORKS DATE 'SHEET 1 of 2 > r