Loading...
HomeMy WebLinkAboutTED4001782.28Ia L 44 �41 94 (i C NOTES: 1. NUMBE'IS AT END OF BARS INDICATE DISTANCE IN FEET FROM CENTERLINE PI ER. 2. PROVIDE 2'-0" AND 2'-3" MINIMUM SPLICE LENGTH FOR NO. 5 AND NO. 6 BARS, RESPECTIVELY. 3. STAGGER ALL LONGITUDINAL TOP BAR SPLICES BY 5'-0" UNLESS NOTED OTHERWISE. 4. ALL NO. 5 BARS SHALL BE AS LONG AS PRACTICABLE 5. TRAIyMVERSE STEEL REINFORCING BARS ARE NOT SHOWN FOR CLARITY. SEE CROSS SECTION ON SHEET NO. 41. 6. ALL DECK TOP STEEL REINFORCING BARS ARE EPDXY COATED; SEE BAR Li,.,. i. T FOR LOCATION OF STEEL REINFORCING BARS SEE SHEET NO.41. 8e FOR LOCATION AND SPACING OF PRECAST CONCRETE TRAFFIC BARRIER ANCHOR BOLTS, SEE SHEET NOS. 44 a 45. ;PiQ��n w < SUPERIOR REPROGRAPHICS i Zr r' , _ - S H T. 4 3 FO R D E"A' 25 TOP- DECK REINFORCEMENT PLAN - SPAN 2 $ 3 SCALE: 3/16"= V-011 ALPHA ENGINEERS INC. CIVIL AND STRUCTURAL ENGINEERING CONSULTANTS RECORD DRAWING 320 ANDOVER PARK EAST SEATTLE, WASH I NGTON 98188 URS MPANY�-� Consulting Engineers and Analysts 1 REVISED PER RECORD aDRwy. 57%o� 3.1 I. E17 Seattle, Washington NO. REVISION I BY APPR. DATE • Corsi. /7 CITY OF RENTON DEPARTMENT OF PUBLIC WORKS DESIGNS DRAWN- CHECKEI B.W. GRADY WAY BRIDGE REPLACEMENT DECK REINFORCI NG PLAN - SPAN 2 8t 3 D. K.H. DATE APRIL,1982 FILE NO. ,M. B.W. T— D.L. SCALE A5 NQp FIELD BOOK --PAGE___ SHEET-33 OF_ 63_ - I APPROVED s7/, WORKS SCANNE 0 MAR 2 8 Z003