HomeMy WebLinkAboutTED4001782.59A. GENERAL B. C. The amount of concrete required to anchor horizontal bends, tees, and dead ends depends on the strength of the soil. The methods of placing concrete to keep the joint accessible is shown in Figure 1. The area in square feet of concrete wnich must bear against the side of the trench is found by dividing the thrust in pounds shown in Table 1 by the safe bearing load of the soil as shown in 'able 2. CRITERIA 1. The sizing procedure is for horizontal or downward thrust only. 2. Meight of :he thrust block must be equal to or less than 1/2 the depth from the around surface to the block base. 3. The thrust block bearing face is approximately rectangular. 4. The concrete blocking shall be as per APWA Specification 74-2.14. SYMBOLS d - Outside Diameter of Pipe in Feet T - Thrust in Pounds at the Fitting (Table 1) SBL - Safe bearing Load in Pounds/Sq. Ft. (Table 2) h - Depth of Trench in Feet W - Width of Trench in Feet A - Area of Concrete which must bear Against the Side of the Trench ,n Sq. Ft. Hm - Maximum Height of the Thrust Block in Feet Dc - Depth of the Concrete Thrust Block to Bearing Surface in Feet Lm - Maximum Length of the Thrust Block in Feet GROUND SURFACE T BLOCK BASE D. CALCULATION EQUATIONS f Dc I 1 W Thrust (in Pounds': T 1. Area of Concrete (A) =Safe Searing Load kin Pounas/Sq. Ft.7 SBL 2. Maximum Height of Thrust B1oGk (MR,) a Depth of Trench in Feet h2 - 'f (Width of Trench in Feet)-ioutside 3. Depth of Concrete Thrust Block Diameter of pipe 1n Feet) W-d2 --�- 4, Maximum Length of Thrust Block (L..) ' Area of Concrete M. A Maximum Height r?r, 5. Required Amount of Concrete (Cu. Yd.1-I.Height x Deoth x Length) x 0.03704 -(Hm x Lm x Dc) x 0.03704 E. EXAMPLE i I. Problem: Calcuiation of the amount of concrete required to block a 9y 0 bend in an 8" C. 1. water main; the normal operating pressure in the pipe will be 65 psi and the soil condition in the area indi- cates sand and gravel. 2. Soiution: Maximum testing pressure (See Table 1) - 300 psi Outside diameter of 8" pipe - 9.05 in,. - 9.05/'.2 - 0.75 ft• Go to Table is The testing pressure of 300 psi, we see that tfre thrust on a 90° bend is 21,360 pounds. Go to Table 2: Table 2 gives the safe bearing load for sand and gravel: 3,000 lbs./sq. ft. Go to Figure is Figure i indicates the position of the concrete for blocking the 90° bend. Go to the specifications of the project and find depth of trench (h) - 4 Beet Width of trench (W) - 3 feet With the above assembled information, we proceed to the final ca I Cu I at I ons: Area of Concrete (A) - ?gust 21 360 a e Bearing Load j pp = 7'12 sq. ft. Depth of Trench h 4. maximum Height of Thrust Block (Mm) - �-- Z ---- - ,f - 2.0 f t . Depth of Concrete Thrust Block (DC) Width of Trench in Feet (W) - Outside Diameter of Pipe (d) • 2 0.75 • 1.13 ft. 2 Maximum Length of Thrust Block (Lm) - Area of Concrete Meigrtt or Concrete ;;W- 2. a 3,56 ft. , Required Mwunt of Concrete -(Height x Depth x Length)x O.C3704 -(►m x Lm x Dc) x 0.03704 -(2.0 x 3.56 x 1.13) x 0.03704 - 0.30 cu . yd . DRAWN CHECKED PROJ. ENGR. DIST. ADM. b. 7,P - -oJeo H-E DOT FORM 221-011 Revised 6 /80 1 - � 1 ° -, ' 0 CAP TEE 1t L* BEND FIGURE I 222 BEND 45° BEND • 5, 1. i .� b T 1 90• BEND NOTE: FOR CONVEX VERTICAL BENDS BLOCKING, SEE APWA STANDARD PLAN NO. 73. TABLE I SIZE PRESSURE PSI THRUS' AT FITTINGS i N POUNDS I TEES DEAD ENDS 9G° BEND 45° 22-1/2" BEND BEND 11-1/4' SEND 3" 300 2,120 j 3,000 1,630 830 43C 4" 300 3,780 5,370 2,910 1,470 ( 750 6" 300 8,500 12,000 6,510 3,320 .1 1,700 811 300 15,100 21,360 11 „50 5.880 3,020 104, 275 21,620 30,570 16,540 I 8,430 4.330 12" 250 33,930 I 48,000 25,950 13,260 6,780 1411 25O 46,200 65,370 35,340 18,030 9,240 16" 225 45,250 64,000 34,620 17,650 9,050 18" 200 50,900 72,000 38,940 99,860 10,18C 20" 200 62,840 88,900 48,080 24,520 12,560 200 90,480 127,980 69,200 35,320 1 18,100 E4" 200 , 141,370 199.960 P 108,190 1 55,140 28,280 36" 200 1 203,580 287,950 155,740 79.400 40,720 TABLE 2 Safe Bearing Loads in Lb./So. Ft The safe bearing loads given in the following taole are for horizontal thrusts when the depth of cover over the pipe exceeds 2 feet. SAFE BEARING'LOAD SOIL Lb. per Sq. Ft. *Muck, peat, etc. 0 Soft Clay 1,000 Sand 2,000 Sand and Gravel 3,000 Sand and Gravel Cemented with Clay 4,000 Hard Shale 10,030 *In muck or peat, all thrusts shall be restrained by piles or tie rods to solid foundations or 5y removal of muck or peat and replacement with oallast of sufficient stability to resist thrusts. REND N TOTAL STATE FED. AID PROJ. NO S"rvo T SHEET.' BRM 12 2-8(2 ) 10 WASH, .I- 405-,3(635) ,no %,111uoc'R 8�W1010 1 CONTRACT �. DATE REVISION BY APP'D o?6, �?? I TIE ROD SELECTION TABLE REGION NO. STATE FEDERAL AID PROJECT NO. SHEET NO. 10 WASH. BRM - 1288 (2) I-405-3(r�35) SIZE PRESSURE PS1 FORCE IN POUNDS NUMBER OF TIE RODS 7I 2 1 3 I 4 I I 6 i 8 10 ! 12 ' 14 I 16 I 24 3" 300 2,120 3/8" 300 3,780 3/8" 611 300 8.500 5/8" 1 1/2" 1 1 3/8" 1 8" 300 15.100 j 3/4" 1 5/8" 1 1/2" 10' 275 21.620 1 3/4„ i i 5/8„ 1/2" 12" 250 33,930 I I 3/4'' I 5/8" i 14" 250 46,200 ! ; i j 3/4'' i I 16" 225 45.250 I j 3/41, ; 5/8" 1811 200 50,900 ; i 3/4" 5/81, 201, 200 62.840 ; 13/4" 5/8,1 , 1 2411 200 90.480 3/4" I 30'' 200 141,370 7/8" 1 36" 200 203,580 + , j ; ; 1" 7/81i i NOTES: 1. STEEL FOR TIE RODS SHALL HAVE AN ULTIMATE STRENGTH OF 40,000 PSI OR MORE. 2. TIE RODS SHALL HAVE NATIONAL -COURSE THREADS WITH AT LEAST TWO NUTS AT THE END OR ONE SELF-LOCKING NUT. 3. STRENGT►+ OF SPECIAL DEVICES USED FOR TIE RODS ATTACHMENT SHALL BE SUFFICIENT TO TRANSMIT THE rORCE TO THE PIPE. 4. TIE RODS SHALL BE GALVANIZED OR COATED WITH 2 COATS OF KO➢PERS COMPANY INC. SITUMASTIC 300-M (16 MIL MINIMUM DRY THICKNESS). 5. STEEL ROD COUPLINGS (STELLAR CORPORATION OR EQUAL) SHALL BE USED TO CONNECT T140 TIE RODS IN ORDER TG GET ADDITIONAL LENGTH. TIE BOLT STAR SUPPLY CORPORATION OR EQUAL CAST ON LUGS FIRE HYDRANT AND GATE VALVE DIVISION OF HIGHWAYS CIV2e 2 7, /983 .-,, � .,_ . "J TIE BOLT "DUC-LUG" STELLAR CORPORATION OR EQUAL "DUC - LUG" TIE ROD ATTACHMENTS AIM Washington State Vr,f Department of Transportation t1jw 1v(b STAR SUPPLY CORPORATION, STELLAR CORPORATION OR EQUAL RETAINER CLAMP H O,r cisTE Fss�O N AL S.W. GRADY WAY BRIDGE REPLACEMENT WATER STANDARD DETAILS SHEET 2B O F 63 7S2 iP Z SHEETS SCAlvhlEo MA,.3 2 8 203J