Loading...
HomeMy WebLinkAboutTED4001783.6FRAME & LADDER OR S7EPS- OFFSET, COVER EL = 409.50 OVERFLOW ELEVA 77ON-- TO PROVIDE DE7EN77ON & OIL SEPARA77ON OVERFLOW EL = 406.96 PIPE SUPPORT(S):- 3" X .090 GAGE BOLTED OR IMBEDDED 2' IN WALL AT MAX. 3" SPACING MIN. ONE SUPPORT. CLEANOUT GATE.• — SHEAR GATE RES7RICTOR PLAT WITH ORIFICE AS SPECIFIED, NOT NEEDED IF ONLY FOR POLLU77ON CON7ROL. ORIFICE = I.o- ROUND SOLID COVET, 6" EX. CURB AST"'!-14I__.T PARK I NG --\ Sc'E PHASE I PLAN SHEET C 3 - BIOFIL TRA T/ON D/TCH (SEE DETAIL) SHTC4 G" C. /. WATER r-'IPE RIP RAP `- END EX. 5' WALK GRASSED "V " DITCH DE TA I L STANDARD GALVANIZED STEEL LADDER/S7FPS CATCH BASIN TYPE ll 54"0 WITH RES TRI C TOR FRAME & LADDER OR STEPS - OFFSET, COVER EL = 411.20' OVERFLOW ELEVA77ON— TO PROVIDE DETEN77ON & OIL SEPARA 77ON OVERFLOW EL = 409.67' PIPE SUPPORTS):- 3' X .090 GAGE BOLTED OR IMBEDDED 2' IN WALL AT MAX. 3" SPACING MIN. ONE SUPPORT. CLEANCu T GATE.• — SHEAR GA 7E RESTRICTOR PLAT WITH ORIFICE AS SPECIFIED, NOT NEEDED IF ONL Y FOR POLLU77ON CONTROL. ORIFICE = I.23" 25 YR. FLOW DE'PTi i 0.82' ROUND SOLID COVEN 61-Fl2"0CMP S = /.00% - 43L F 12" 0 CMF S = 1.26% — 64LF 12" 0 CMP S = 2.08% - EX CAP I I 1 I RIM EL = 410.87' INV. EL = 404.94' - 12" k21 310-.FILTR4TION SWALE DETAILAo HYROSEEDiNG OR PLANTING OF BIOFILTRATION SWALE SHALL BE ACCOMPLISHED PRIOR. TO STORML INE INSTALLATION AND THE GRASS SHALL BE FULLY ESTABLISHED PRIOR TO RELEASING 2TA. 3*50 , 5' L T s-36"0 STORM DRAINAGE INTO SWAL.F_, 48" MH */ TYPE /l I.E. = 404.95' RIM EL = 408.70' INV. EL = 402/0' - 12" BUILD OVER EXISTING 12" CMP PIPE :70NT'RACTOR TO VERIFY EX. PIPE ELEVATION 4/0 STANDARD GALVANIZED STEEL LADDER/STEPS SEE PHASE I PLAN SHEET C 3 ce #10 CATCH BASIN TYPE ll 54'0 W/TH RES TRk,"."' TOR STA 3+50, 35' RT. OIL./ WATER SEPARATOF RIM EL. = 408.80 INV. EL- = 402.51 - 12" SEC. 3' TWV , . a N. R. 5 E. T A NA COR TES EXTENDED S TA. 6f 87 /3' S 88' 02' 27" E 140.00' SCALE: /" = 20' I.E. = 409.50 RIM EL = 41L15' INV. EL = 405.42' - 36" INV EL. = 407.67' - 12" i2LF 36" 0 CMP S = 0.50% fTYP/CAL BOTH ENDS) GOLF GRASSED "V" DITCH 3EGIN RIO-FIL.TRATIGNSWALE RIP-R4P W1 4" - 8" QUARRY ROCK 10' x 5` x 12" THICK I.E. = 409.45 54" CB x/0 TYPE l/ CONTROL STRUCTURE RIM EL = 411.20' i INV. EL = 404.95' - 12" B 36" OVERFLOW EL. = 409.67' RIP -RAP W/ 4., 8. I.E. = 408.50 QUARRY ROCK lO x 5' x 12" DEEP 19OLF 8/0-FILTR4TION SWALE S = /.29% ROCK CHECK DAMS 50 0. C. ( TYP. ) SAME AS SHOWN IN DETAIL SHT 2 OF 8 54" TYPE l / - CA TCH BASIN * /O SCALE /" = 2' 54 " TYPE // - CATCH BA SIN* 8 SCALE /" = 2' DA TUM: K.C.A.S. BENCHMARK: B.M. ELEV. = 397.52' - CHISELED SQUARE AT FACE CONC. WALK BY CATCH BASIN, P.T. CURB RETURN N.E. CORNER INTERSECTION N.E. SUNSET BLVD. & ANACORTES AVE N.E. NO TE, CITY INSPECTOR WILL MARK EXISTING UNACCEPTABLE CURB AND GUTTER AND SIDEWALK ON ANACORTES AVE. THAT MUST BE REMOVED AND REPLACED TO CITY OF RENTON STD'S. NO TE: INSTALL CLEAN OUTS AT ALL ROOF DRAIN ANGLE POINTS. XPPRG'VAL Pam. �N �_m' TOP OF BANK EL. = 408.50 STORM DETENTION SYSTEM CONSTRUCTED END 8/0-FILTRATIONSWALE AS PART OF PHASE I DEVELOPEMENT RIP -RAP W1 4" - 8" BIO-FILTRATION SWALE NOT CONSTRUCTED. QUARRY ROCK IO' x 5' x 12" TI-!I CK I.E. = 407.00 i 5LF 12" 0 CMP 5=20% STA 3+41 122' RT, L . = 409.0 4 #9 TYPE „ CITY OF R E N T O N RIM EL [ROCK I.E. = 4n g a - 36,, EADWALL lE. = 4rF. DO'_ i2„ DEPARTMPNT OF PUBLIC WORKS OW = 408.50 89 C TO C SUNSE T PA RK A P T 'S 80LF 48"Qs CMP DETENTION TANK S 0.5 ,� PHASE l l = f STORMY UTIL I T Y &GRADING PLAN t Avv�� �Lt .�tr- pca g 'Vz61/�� DESMED: . RM M. r. f DATE: JANUARY, 1991 FILE N0 64K- 0ol-9oI NT t uI �r 92- � 5 - -4- `>'3 DRAWN: DT -- CHECKED: MT SCALE. 1 -20' FEW Boon: PAGE: NO. B'Y APPR. DATE APPROVED: SHEET: C 3 OF: 8 DIRECTOR OF PUBLIC WORKS t i r