Loading...
HomeMy WebLinkAboutTRO4101783.13A \ N�\ \ \\ `o JUNCTION BOX \� \ �G N� U1 Ol INSTALL ALUMINUM DAVIT STYLE LIGHT STD. W/ 150 WATT HP SODIUM VAPOR/LUMINAIRE & LAMP -- 25' MOUN77NG HEIGHT LUM = M—C—II, GE M250A2 2O INSTALL TYPE "B" JUNC77ON BOX. LUMINAIRE SCHEDULE POLE LOCATION MH ARM LENGTH LUMINAIRE 3 + 00 25' 6' 150 WATTS 4 + 64 25' 6' 150 WA TTS CONDUIT & WIRING SCHEDULE RUN NO. CONDUIT SCHEDULE 1 EXISTING EXISTING 2 1 112" PVC SCH. 40 2 — #8 T H. W. CU. 3 1 112" P VC SCH, 40 2 — #6 T.H. W. CU 4 I I/f" PVC SCH. 80 2-2" PVC SCH. 80 2 - *8 T.H W. CU. FUTURE SIGNAL c,► I � c� N� 2 _ \ INSTALL 2 - 2" COND FUTURE TRAFF 5SIGNA s ice. 5 \ 1 ------- ---- --- ---� V� \< 42 -F4R- - -STA 0+00.00 - S ANACORTES AVE N.E. 5 ' STA 167 + 89.30 0 144 �. NE SUNSET BLVD. "55 \ �a I eAB �$NDUIT - �$ ' '' S8' \ � r. V. 0 \ o p�� ASPHAL ! G 4 ``` // o D AY 2 \\ "ilk Ilk \\ 133 \\\ > L rss9 \ \ Zo, N� \ 2 \\ EXISTING CONCRETE' \ \ CURB AND GUTTER i S D. n/®. 3125C .3727 C EXIS77NG CONCRETE' CURB AND GUTTER GENERAL N 0 TES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS AND SPECIFICATIONS AND THESE PLANS 2. THE LOCA77ONS OF FEATURES ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. J. INSTALL ALL STREET LIGHT LIGH77NG MATERIALS SHOWWN ON THESE PLANS, EXCEPT AS NOTED. ALL MATERIALS SHALL BE NEW AND OF 774E BEST AVAILABLE GRADE OR QUALITY, EXCEPT AS NOTED. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO 774E CITY OF RENTON FOR MA TERIAL S APPROVAL AT THE EARLIEST POSSIBLE DA TF 5. ALL WORK SHALL BE CONSISTANT WITH U77LITY AGENCY REQUIREMENNTS THE CONTRACTOR SHALL CONTACT ALL PER77NENT U77LITY AGENCIES FORTY EIGHT (48) HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE THE WORK WITH THE U77LI77ES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES TO EXISTING U77077ES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED U77LITY COMPANY AND THE CITY IMMEDIA 7L Y UPON DAMAGE. 7. THE CONTRACTOR SHALL N077FY THE CITY OF RENTON CONSTRUCTION ENGINEERING DIVISION AT 277-5570 FOR INSPEC77ON PURPOSES TWENTY—FOUR (24) HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED (BACKFILLED) UN77L IT HAS BEEN EXAMINED BY THE ENGINEER. I �i EQUA TION 6"ST r� .0 1+5p R-123108' 2f0o �— —: !1 i I - 2. c� A ,� X� P R VA 12" ALDER tv ry JUNC77o ox g" ALDER h 24" FIR ►A STA 1+14-14' RT RELOCATE EXISTING STREET LIGHT TO 1+27-21.5' RT REMOVE EXISTING CONDUIT ALONG ANACORTES AVE. NE AFTER TERMINATING ALONG NE SUNSET BLVD. 3 S CAL Lg-- I " LEGEND ® JUNC77ON BOX �— EXISTING LUMINAIRE NEW LUMINAIRE 0 CONC. PAD ----------- CONDUIT 20' R TM EN TS ARK APA SUNSET P v �� �o N PHASG ryX 5So � z cv Q Q� EXISTING CONCRETE' I� CURB AND GUTTER -- — — EX/STING 5' CONCRETE WALK e SS — - - — 12 --=-3+00 I-50 r'"er ---�0 I 1. ANACORI/E. NE 243. �o' — TES {— �_ ----------- ---------------------------NE -5'-MVCREX-*Xnt`--- J------------- STA 0+30- 5 L T xav RELOCATE EXIST. STREET LIGHT TO An �� rT A ., -L35 - 42' R T.Q� EXTEND RIGID CONDUIT AND CIRCUIT TO, NEW JUNCTION BOX LOCATION. ' " AS - BUILT " P L�ANS WERE-PTTE P-A P E D B Y TOUMA ENGINNERS FROM A FIELD SURVEY w 00 co Obi S ARTMEN SUNSET PARK AP PRASE 11 7 a � TOUMA ENGINEERS 15668 West Volley Hwy -Seattle, WA 98188 (206) 255-4100 t Aoo��� Go.0 ova i NO. REVISION P. a 1 1 z /2& �1/ BY I APPR. I DATE N RECOMMENDED FOR APPROVAL BY TRANS FORT A-T1ONl DEvE"?MENT OEAvICE" J ?", 5+00 .5,4L 9R oof , / 79J CITY OF RENTON DEPARTMENT OF PUBLIC WORK- z1 ANA COR TES AVENUE N. E. STRUT LIGHTING PLAN DESIGNED: MT DATE: JANUARY 1991 FILE NO. 647-001-901 DRAWN: DT CHECKED: MT SCALE: I" = 20' FELD BOOK: PAGE: APPROVED: SHEET: C8 OF: 10 DIRECTOR OF PUBLIC WORKS ..#fax9A 109 6