HomeMy WebLinkAboutTED4001806.2S T ORM WA TER DRA I NA GE NO TE:�
1. BEFORE ANY CONSTRUCT70N OR DEVELOPMENT AC770TY OCCURS, A
PRE- CONS TRUCTION1 MEETING MUST BE HELD WITH THE C17Y OF
RENTON PUBUC *10?1<S„ DESIGN ENGINEER,
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WMTH THE '1988
STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION' PREPARED BY W. SD. 0. T., AND THE AMERIC AN
PUBUC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF
RENTON DEPARTMEWT OF PUBLIC WORKS
.3. THE STORM DRAIN :S'YSTEM SHALL BE CONSTRUCTED ACCORDING TO THE
APPROVED PLANS IWIC H ARE ON FILE IN THE DEPARTMENT OF PUBLIC
WORKS ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE
Wfi'ITTEN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF
PUBLIC WVRK.$, DESIGN ENGINEER OR STORM WATER U PLI IY.
4. A COPY OF THESE APPROVED PLANS MUST BE ON THE " SITE
WHENEVER CO'NSTROC770N1 IS IN PROGRESS
5. DATUM SHALL BEE U.SG.S UNLESS OTHERWISE APPROVED BY THE
CITY OF RENTON U"PARTUENT OF PUBLIC WORKS. REFERENCE BENCHMARK
AND CLEVAT70NS ARE NOTED ON THE PLANS
6. ALL SEDIMENTATIOI',I,,'EROSION FACILITIES MUST BE AN OPERATION
PRIOR TO CLEARING: AND BUILDING CONSTRUCTION, AND THEY MUST
BE SAT)SFACTORILYMANTANED UNTIL CONSTRUCTION IS COMPLETED
AND THE POTFN77AL FOR ONSITE EROSION HAS PASSED.
7. ALL RE TEN TIONIVEITNT70N FACIU77ES MUST BE INSTALLED AND IN
OPERATION PRIOR M OR IN CONJUNC77ON WITH ALL CONSTRUCTION
ACTIVITY UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF
PUBLIC WORKS. SNIRM WATER UTILITY.
8. GRASS SEED MAY LIE APPLIED BY HYDROS£ED/NC. THE GRASS SEED
MIXTURE, OTHER TITAN CITY OF RENTON APPROVED STANDARD MIXES,
SMALL BE SUDMI TTED BY A LANDSCAPE ARCHITECT AND APPROVED BY
THE OEPARWEN T GIF PUBLIC WORK4 STORM WATER UTILITY.
9. ALL PIPE AND APPURTENANCES _SHALL BE LAID ON A PROPERLY
PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7--02.3(1) OF
THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIN FOR
ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY
LEVEUNG OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION
MATERIAL AS WELL AS THE PLACEMENT AND COMPACTION OF REQUIRED
BEDDING MATERIAL TO UNIFORM GRADE SO PHA1- THE ENTIRE LENGTH
OF THE PIPE MILL YE SUPPORTD ON A UNIFORMLY DENSE' UNY7EDING
BASE. ALL PIPE- E DD1NG SHALL BE APWA CLASS 'C" AfTM THE
EXCEP77ON OF PVC; PIPE. ALL TRENCH BACKFILL SHALL BE
COMPACTED TO AIUI. 95X FOR PAVEMENT AND STRUCTURAL FILL AND
9OX OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL
BE 6' UNDER AND OVER P. V.C. PIPE
la GALVANIZED STEEL. AND ALUM/NIUMIZED STEEL PIPE FOR ALL
DRAINAGE FACWTIES SHALL HAVE ASPHALT TREATMENT /'I OR BETTER
INSIDE AND OUTSIDE.
11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10' FEET Of THE
SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15' FEET FROM THE
TOP OF ANY CHANNEL BANK.
1Z. ALL CATCH BASIN GRATES SHALL BE DEPRESSED Q 10' FEET BELOW
PAVEMENT LEVEL.
1.1 OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT -OF -WA 1
WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY
OF RENTON DEPARTMENT OF PUBLIC WORKS; DESIGN ENGINEER.
14, R" FOR EROSION PROTECTION OF ROADSIDE DVTCHES; WHERE
REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH t-
1' FOOT AND MUST MEET THE FOLLOWING SPECIFICAT70INS:
4'-8%40R-7OX PASSING,,- 2'-4' ROCK13OX-40X PASSING` AND -2'
MOCKIIIOX-20X PASSING.
16. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE
CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY
THE DEPARTMENT OF PUBLIC WORKS; DESIGN ENGINEER OR STORM
WATER U77UTY. AN ACCURATELY DIMENSIONED CERT7FIED
'AS -BUILT' DRAWING OF 7NIS DRAINAGE SYSTEM WILL BE SUBMITTED
TO THE CITY OF RENTON UPON COMPLE170N.
16. ISSUANCE OF THE BUILDING OR COINSTRUC17ON PERMIT BY THE CITY
OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL
OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE
WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT
ACCEPT ANY 09UGA77ON FOR THE PROPER FUNC770NING AND
MAINTENANCE OF THE SY57EW PROVIDED DURING CONSTRUCTION.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE
SAFEGUARD, SAFETY DEVICES; PROTECTIVE EQUIPMENT, FLAGGERS;
AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE HEALTH, ANL_;
SAFETY OF THE PUBLIC;, AND TO PROTECT PROPERTY IN CONNEC77ON
WNTH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY
WORK WITHIN THE TRAVELED RFGHr--OF- WAY THAT MAY INTERUPT
NORMAL TRAFFIC FLOW SMALL REQUIRE AN APPROVED TRAFFIC
CONTROL PLAN BY THE TRAFFIC ENGINEERING DIV. OF THE
DEPARTMENT OF PUBLIC WORKS. ALL SECTIONS OF THE W. S D. O T.
STANDARD SPECIFICATIONS 1-07-24 TRAFFIC CONTROL. 5IHALL
APPL Y
I & SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT
LOCA77OIN IS WITHIN THE AQUIFER PROTECTION AREA.
GENERAL NO TES .
ALL; WOFK MATERIALS SFALL BE IN ACCORDANCE WITH THE STAXDAYMS SAND
SFECIFICATIONS OF CITY OF ILEI►TON AND APPLICABLE PORTION OF THE
LATEST EDITION OF APWA STANDARDS AND SPECIFICATIONS.
MINIMUM SLOPE FOR SIDE SEWER IS 2.02
ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE, LND IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND
CGY&P.ECT LOCATIONS SO AS TO AVOID DAMAGE OR DISTURBANCE.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL
NECESSARY PERMITS PRIOF? TO STARTING CONSTkUCTION.
ALL, WORK SHALL BE ACCOK?LI SHED IN ACCORDANCE wI1'n WASHINCTON
INDUSTRIAL SAFETY AND HEALTH ACT (WISF:A).
INSPECTION WILL BE ACCOMPLISHED BY A REPRESEKTATIVE OF THE CITY.
IT SHALL BE THE CO!,TRIACTOR'S RESPONSIBILITY Yb NOTIFY THE CITY IN
ADVANCE OF BACKFILLING ALL CONSTRUCTION. BACKFILL FOR STREET
CROSSINGS SF.ALL M 5/8" KINDS CRUSHED ROCK.
F
l
In•___ _
1/B' RA6E-WWIDE
8o2DER
_'a' 5MC :5 5PACZD-5 4'
5 INDICATf!D- u+. 11b'
v
,t'
ry
CAST ICON RING AND COVE12
Tt�O• �o - /Bolds
FERGUSON & SONS INC 91704
PLUG TO br- 5EAIID W SPME
W I,JIJCR AS ww SEWtR 1pMT5.
i
p ..
I
trm
F161'12 JOIQT
PAC BUJ
Y6 BEAID
SANITARY CLEAN OUT DETAIL
N. T. S.
RECOMMEND
FOR ,WROY
BY
Yl/.4F:5 BY
RECOMMENDED
FOR APPROVAL
PLAN
A A1Cf!®2
rIm ►![a to two 1M1K Dom.
aa"4. TI liR %MVE M. PAX-hrq
t FI no
IS StRlon. HI KW .N KSl
f[RIl!! lL1GT%! Tl FIT
r womolzu lam P/Pi
W Lw �,
F�l
"C" CHANNEL 2r L& "C" C4 MNEL r LO.
'V" CHANNK 2r LO.
Section A•A
Y Yl7optal loss s5 1 `l _
Port 1[ddlL os
msTr�:
l•Y- !a Klee. scr.Cs
YTL M6ii.. Y.s[Ko
•!P►ifZ ALL Yt " F$ low nrt
KTKR LO► M RR r* &hLwRt ItT ,qyv�
s r W R.lr 5(•l t' OFFSET TAe AT OC I-04
ELEVATION
TEMPORARY 2` SLOW -OFF ASSEMBLY
FOR MAWS A00 SHALLM
1
0 AND cwlLL Rr-Qm
A FIRE HYDQh►1T• FOIZ eLo-O-OFP
RECOMMENDED
FOR APPROVAL
BY hPOUA-1 (yl'lklr'duyt/ I2/ 06/ q6
PV,4T�R "774 _/ 7-Y
SPgING LOt ',-
4-1j- INSERTS
---I-041 LENT. MOLE
2r-
EACH ENO
I I.
al
• I 1:
Section 11-8
OIL/WA TER SEPIA RA TOR DE TA IL
N. T.S.
-sTL. "^T-Z AA Cbp4C. APRON
-WtT/N FORA j dl D1.:OP,IL TO CAI vN
I
0 ;7;a 'At
AM' 5,Qu�fils
lH�os ca�lC�:�rR - --
*` tH BAs;;�
m000 7134 co"CR1=ra
00"Cp ''Iff "-KON
fT-.!,)I
o,•
'v jrl�
IW
�t'k t ►�,w1 [
►}O r1[ : ALA- FOPtST RUCT 101•i 117 DS M /�� O � CIu1C)(
wirm N64 ATAHD/.TsD APCC4FICATIO+-5 F"z
RDAo , BRICGt AND 1 j_r IPoi` 1_0N5TFW1104.!I
CATCH BASIN SUMP
A'. T.,,.
EX. 27" CONC. TO BE
REMOVED (SEE NOTE
SHT I OF 2 )
(30. 0 TYPE 11 CB* I
SCALE: I" = 2'
27" CONC.
60 0 TYPE ll CB* 3
SCALE. I" = 2'
11 AS - BUILT " PLANS WERE PREPARED BY TOUMA
ENGINEERS FROM FIELD SUR EY AND INFORMATION
PROVIDED BY CONTRACTOR. � � &11201/ e%
947
•y° i s'
°
*Ak°� ..�
!
PER CITY OF RENTON RED MARKS
DT
6120190
NO.
REVISION
BY
APPR.
DATE
60" 0 TYPE / / CB* 2
SCALE: I" = 2'
7" CONC
60" 0 TYPE ll C8 *4
R--190602
CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS
SOUND MITSUBISHI
DE TA /L SHEET
DESIGNED GS DATE DECEMBER !989 FILE NO.525-094-891
DRAWN DT
CHECKED GSMT SCALE NOTED FIELD BOOK 33 _PAGE 25
APPROVED SHEET 2 OF- - 3
DIRECTOR OF PUBLIC WORKS
SCANNEQ MAR 2 8 Z003 /8-3"i-fo