HomeMy WebLinkAboutTED4001810.1s 012ea2• w O
e
- PHA SE l l PHA SE l
o+po 37Q4. 1+00 a
r
N 0053i4' E $$ / ss MH
ss mm 'm
0CA
sue, FH co
sr MH
a
9 x20
II \
J
90 -__, N 0�i6
E W 67. 154 ' 1
�o
g8
I 0' 12' 1 ' I \ , `Sc, 100
1
02
} ✓ N / /� / / iNf t T
\ \
8 1// 0.
1 ®�0
'x2' ' r / \ d yq
30 8�5 x 1 151 9 x20
cp o
(blo 4 ;z,
°j 9 4
m 0) 225. o 3
78�
lb
CLEARING LIMITS
TYPICAL l /
•roG�� • ce
ff7r(97hLw1 WlA lllgfi? DfirAlfri Auff PHASE l! PHASE I \ y9
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT AC71Vl iY "CURS, A
PRE -CONSTRUCTION MEETING MUST BE HELL WTH THE ,ITY OF \ \\y�t-
RENTON PUBLIC WORKS, DESIGN ENGINEER.
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 01988
STANDARD SPECIRCA77ONS FOR ROAD, BRIDGE AND MUNICIPAL
CONS7RU/ 77ON" PREPARED BY W.S.D.O. T., AND THE AMERICAN
EX. CB TYPE 2
PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF
RIM=102.90
RENTON DEPARTMENT OF PUBLIC WORKS.
IE =91.50
J.
774E STORM DRAIN SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE
F
APPROVED PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC
300 LF BIOFILTRATION
WORKS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE
HE
TRENCH
WRITTEN APPROVAL FROM 774E CITY OF RENTON DEPARTMENT OF
PUBLIC WORKS, DESIGN ENGINEER OR STORM WATER JTILI7Y.
4.
A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE
WHENEVER CONS7RUC77ON IS IN PROGRESS
5.
DATUM SHALL BE U.S.G.S UNLESS OTHERWISE APPROVED BY THE
CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. REFERANCE BENCHMARK
AND ELEVATIONS ARE NOTED ON 774E PLANS
�
3.0' 9' MIN � -GRAVEL PARK/NGa
6.
ALL SEDIMENT4770N/EROSION FACIL177ES MUST BE IN OPERA7ION
PRIOR TO CLEARING AND BUILDING CONSTRUC770N, AND THEY MUST
BE SATISFACTORILY MAINTAINED UN77L CONSTRUCTION IS COMPLETED
0.5' MIN
AND 774E P07EN77AL FOR ONS77E EROSION HAS PASSED.
MUST INSTALLED IN
j \
7.
ALL RE TENTION/DE7ENT70N FACIL177ES BE AND
OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION
AC77VI7Y UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF
12" MIN
Y: PUBLIC WORKS, STORM WATER U77LIT
II
1�.
GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED
MIXTURE, 07HER THAN CITY OF RENTON APPROVED STANDARD MIXES,
SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY
B10-FIL IRA TION SWALE DETAIL
THE DEPARTMENT OF PUBLIC WORKS, STORM WATER U77LITY.
Nra
SECT/ON A - A
9.
ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY
PREPARED FOUNDAT70N IN ACCORDANCE WITH SEC77ON 7-02.3(1) OF
THE CURRENT STATE OF WASHINGTON STANDARD SPECIRCA TIN FOR
ROAD AND BRIDGE CONS7RUC770N. THIS SHALL INCLUDE NECESSARY
LEVELING OF 774E TRENCH BOTTOM OR THE TOP OF 774E FOUNDATION
MATERIAL AS WELL AS 774E PLACEMENT AND COMPACTION OF REQUIRED
BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE EN77RE LENGTH
15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE
OF 774E PIPE WILL BE SUPPOR7D ON A UNIFORMLY DENSE UNYIEDING
CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY
BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE
THE DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM
EXCEP77ON OF PVC PIPE. ALL 77?EN(H BACKFILL SHALL BE
WATER U77UTY. AN ACCURATELY DIMENSIONED CER77FlED
COMPACTED TO MIN. 95X FOR PAVEMENT AND STRUCTURAL FILL AND
"AS -BUILT" DRAWING OF THIS DRAINAGE SYSTEM MLL BE SUBMITTED
90% 0774ERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL
TO THE CITY OF RENTON UPON COMPLE770N.
BE 6" UNDER AND OVER P.V.C. PIPE.
16. ISSUANCE OF THE BUILDING OR CONS7RUC710N PERMIT BY THE CITY
10.
GALVANIZED STEEL AND ALUMINIUM/ZED STEEL PIPE FOR ALL
OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL
DRAINAGE FACILITIES SHALL HAVE ASPHALT 7REATMENT #1 OR BETTER
OBLIGA77ON AND/OR LIABILITY CONNECTED WITH STORM SURFACE
INSIDE AND OUTSIDEE,
WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT
ACCEPT ANY OBUGA77ON FOR THE PROPER FUNCTIONING AND
11.
S7RUCTURE5 SHALL NOT BE PERMITTED WITHIN 10' FEET OF THE
MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUC770N.
SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15' FEET FROM THE
TOP OF ANY CHANNEL BANK.
IZ 774E CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE
SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS,
12.
ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0. 10' FEET BELOW
AND ANY 07HER NEEDED AC77ONS TO PROTECT 774E LIFE HEALTH, AND
PAMWENT LEVEL.
SAFETY OF THE PUBLIC, AND TO PR07ECT PROPERTY IN CONNECTION
WITH 774E PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY
13.
OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT-OF-WAY
WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY IN7ERUPT
WILL NOT BE ALLOWED UNLESS SPECIRCALLY APPROVED BY THE CITY
NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC
OF RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER.
CONTROL PLAN BY THE TRAFFIC ENGINEERING DIV. OF THE
DEPARTMENT OF PUBLIC WORKS ALL SECTIONS OF 714E W.S D.O. T.
14.
ROCK FOR EROSION PR07EC77ON OF ROADSIDE DITCHES, WHERE
STANDARD SPECIF70ARONS 1-07-23, 7RAMC CONTROL, SHALL
REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF
APPLY.
I' FOOT AND MUST MEET THE FOLLOWNG SPECIF7CA BONS.
4"-8"/40X--70.9 PASSING; 2' 4" ROCK/30Z 409 PASSING; AND -2"
18 SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT
ROCK/10%20X PASSING.
LOCA770AI IS WITHIN TIE AQUIFER PROTECTION AREA.
x00
1-
I.E. = 91.50
W/TRASH RACK
15 LF /5"0 G.P.-
S = 8.67%
RIM =96.4
IE =90.20
FM
In
L R
1�
4� PEDESTRIAN SIGN
SEE DETAIL
(TYPICAL)
SEE DE TA I L "A "
SHEET 3 OF 3 p
\ a
H \ FH
- 8+00
LEGAL DESCRIPTION
LOTS 1 THROUGH 8 OF ONE VALLEY
PLACE AS RECORDED IN VOL. 125,
PAGE 40 OF PLATS, RECORDS OF
KING COUNTY, WASHINGTON.
SCALE
1'" 40
- NEW JO' DRI VEWA Y
PER CITY STDS
VICINITY. MAP
PEDESTRIAN
CROSSING
AT
TALBOT ROAD
SOUTH
NZ
SSE 179 TH ST
Al)�
�
5�
I PL
11+01.7
w
MH
9+00 sr Aw
10+00ss
sr MN 1
p
•:
-
EDESTRIAM SIGN
�, Sw
,: , .
SwN
SAN
SEE DETAIL'S
R I6 7
0
ry
ssMH
I(TYPICAL)
RAM P
cr
h
4" x4' x5'
HIGH TREATED
_= vLUMBER
i1111STINO GROUND
,Q,
61- c 1R
1¢ 9 20
f YP 1 -- �-
v�\ O' .C. E DETAIL O
lb.
4 g
7¢'
N 7816 �8 ry
tD
an
B10-FI! TRATION SWALE
HYD ING OR PLANTING OF B/O-F/L7RAT10N ALF BIOFIL TRATION
SWALES SMALL BE ACCONPLISI-ED PR/OR TO TRENCH
NCH
STORNL/AE /NSTALL4T/ON AW Ti-E C SELL
BE FLLLY EST49LISI-E'D PRIOR TO RaF� JM STORW
DR4INAGE INTO SWALES.
S 00 55'34" W •� 198.45' ASPHALT DRI_VEWAY
7Amomw4® ( y]
G 6 9' ARO /N - ®- , 12 " x 18 " PEDESTRIAN SIGN
L
� L �2 \ �
_ SO 34"W _
198.38SPHALT DRIVEWAY PRECAST CEMENT CONCRETE
_ BUMPER CUB (TIP ALL SPACES)
ti
�J7
590.
0
Q)1- SEE DETAILS SHT 3 OF 3
W
Q)
4 \
�
S 00 5534" W _ : �• P H • '
1 216216.68' _ ASPHALT DRl Q�'� o� w •
I Ill \s•��
�I
GR VE P R \
<19
Vijyp S� , i
KIM = my. o
IE =88.00
FOR W7AL
NO.
FH. -' FH. 4CCESS ADDED
REVISION
- /p2 EX. CB TYPE 2
RIM EL. = IOO.00
I.E. = 87.00
TO EXISTING
DETENTION POND
/00
MH
r
S i CIO
CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS
SOUTH PARKING L L i
VALLEY MEDICAL CENTER
GS ails/so DESIGNED: G.S. DATE: 3/90 FiLE NAME:559-002-891
DRAWN: D.O. / G.S.
CHECKED: SCALE: NOTED FIELD BOOK: PAGE:
BY APPR. DATE APPROVED: SHEET: 2 F: 3
DIRECTOR OF PUBLIC WORKS
<
d
r�
0
o ad
o �r
Oz
I�
aVAtvr�k A 4 0 4jjj I Q ®3 -34fw