Loading...
HomeMy WebLinkAboutTED4001812.2REVISIONS: REVISED PER THE CITY OF RENTON'S :REVISED PER THE CLIENT'S REQUEST :REVISED PER CITY OF RENTON'S :REVISED PER CITY OF RENTON'S 4-8-97 COMMENTS & REDLINES 7-12-95 DJW 6-13-96 DJW REDLINES 11-11-96 DJW COMMENTS 4-14-97 DGS Cr) 015 L0 m 0 0 0 0 0 0 0 0 m m CU 0 0 0 u7 0 0 CD L OJ L0 ED ro 0 J I- V m x N CU E ro ro ry 3 L 60"0 CONC. CATCHBASIN 2.0' MIN. 12'0 CMP RISER. 12"0 N -12 OUTLET PLAN VIEW CB #3, (TYPE II - 60"0) W/ - SOLID, 24"0, LOCKING COVER \. RIM = 332.0 LADDER (PER KING CO. STD. DWG. #2-006) --- SOLID, 24"0, LOCKING LID SHEAR GATE (PER KING LIFT ROD TO SHEAR GATE. CO. STD. DWG. #2-026) EMERGENCY OVERFLOW ELEV. = 325.94 . ­ 11 t _'_ \ 6" ELBOW O.F. ELEV. = 322.84 6" ELBOW ORIVFICE ELEV. = 322.34 ,7u� ORIFICE DIA. = 2.46" 6" ELBOW O.F. ELEV. = 321.74 - 36"0 CMP ___. _ _.. -- . _...... 6" ELBOW ORIVFICE ELEV. = 321.24 INLET r` --- 2.0' MIN. ORIFICE DIA. = 2.51" INV, (12" OUT(W.) & 36" IN(s.) = 319.94 FLOW RESTRICTION _ ELBOW. (TYP.) ORIFICE ELEV. = 317.94 REMOVABLE, WATERTIGHT, COUPLING. (OPTIONAL) 0.5' MINIMUM ORIFICE ELEV. = (SEE RESPECTIVE DTLS.', DRILL A SHARP EDGED, HOLE IN A 12 GA. METAL PLATE WELDED TO THE BOTTOM OF ELBOW. 2.0' MIN. 12"0 N-12 INLET DRILL A 2.07" DIA. HOLE IN A 12 GA. METAL PLATE WELDED TO BOTTOM OF RISER PIPE. 12" CMP RISER ELBOW OVERFLOW. ELEV. _ (SEE RESPECTIVE DTLS.) -� �- 0.5' MAXIMUM 6`+ CMP RESTRICTOR ELBOW SCALE: 1' - 2' 24"0 ACCESS OPENING THRU SAFETY GRATE. r; LADDER (PER KING CO. STD. DWG. #2-006) s ' --- SOLID, 24"0, LOCKING LID 48 0 CONCRETE ACCESS RISER. 12'0 CMP - - ., RISER.- l 12"0 N-12 .......'`'"� OUTLET 1 FLOW RESTRICTION -- ELBOW. (TYP.) PLAN VIEW SAFE 1 ,l 36"0 CMP INLET r � 2.0' MIN. TY LANDING GRATE. CB #9, (TYPE II - 60"0) W/ SOLID, 24"0, LOCKING COVER RIM = 348.0 SAFETY LANDING GRATE. -- -- WITH 24"0 OPENING 48"0 CONC. ACCESS RISER EMERGENCY OVERFLOW ELEV. = 339.20 6" ELBOW O.F. ELEV. = 336.00 6" ELBOW ORIVFICE ELEV. = 335.50 ORIFICE DIA. = 2.19 ` 6" ELBOW O.F. ELEV. = 334.80 6" ELBOW ORIVFICE ELEV. = 334.30 ORIFICE DIA. = 2.01" INV412" IN(N.), 12" OUT(N.W.) & 36" IN(s.) = 333.20 }r, -- 12" CMP RISER - FLOW RESTRICTION ELBOWS f;r'Jf`j (SEE DETAIL THIS SHEET.) i f � I LIFT ROD TO SHEAR GATE 111 •- �, '- 12" CMP RISER FLOW RESTRICTION ELBOWS (SEE DETAIL THIS SHEET.) "J -SHEAR GATE (PER KING - t r r, CO. STD. DWG. #2-026) /f -;ffrr'i I ORIFICE ELEV. = 331.20 DRILL A 1.84" DIA. HOLE IN A - 12 GA. METAL PLATE WELDED TO BOTTOM OF RISER PIPE. 12" OUTLET --' STRAP TO WALL (3.0' O.C., MAX.) GOLF OF 108"0 CMP DETENTION TANK � I i S 0.0000 (FLAT) - TOP OF TANK ELEV.= 339.20 F 108"0 CMP DETENTION TANK I i i i S = 0.0000 (FLAT) CB #4, (TYPE II - 54"0) W/ --, SOLID, 24"0, LOCKING COVER RIM = 332.0 TOP OF TANK 2LF OF 2"0 D.I.P. - ELEV.= 325.94 - INV. (12") 324.30 I IN V. (36") 319.94 ' f ; BOTTOM ELEV. = 317.94 R /8/2os CB #10, (TYPE II - 54"0) W/-,,,, SOLID, 24"0, LOCKING COVER \ RIM = 351.0 SAFETY LANDING GRATE. - - WITH 24 0 OPENING 2LF OF 2"0 D.I.P. -� { 1.................. . �........... 5ipi . r INV. 12" = 344.00 INV. 36" = 333.20 BOTTOM ELEV. = 331. 20 A. DI ►r ' o 1 12 s��MA L EMS .fit, EXPOES: MAY 6, 1997 n rn I L 0 rn I �t (D 0 N 1-11 z 0 a. 00 00 00 rn 3 I.►.i QJ W V) 0 0 r) w F- V) Y Q_ x w 0 z Q 0 r td oz od bx`od Mro o�y r N �N H `b b� �d 92-11 PROJECT NO. DJW DRAWN BY 11-22-93 ISSUE DATE 1 04-14-97 SHEET REVISION SOUTH DETENTION TANK CROSS-SECTION 1 rn) SCALE: 1• - 4rFD- tic-is�z o o PACIFIC ENGINEERING [DESIGN INC. o CIVIL ENGINEERING AND PLANNING CONSULTANTS SOUTH DETENTION TANK CROSS-SECTION 1 rn) SCALE: 1• - 4rFD- tic-is�z o o PACIFIC ENGINEERING [DESIGN INC. o CIVIL ENGINEERING AND PLANNING CONSULTANTS