HomeMy WebLinkAboutTED4001923.3t 30' R/W 50' i 23' W Z_' J; I z NEW CONC, CURB & �I GUTTER(TYPE "A") tz SEE DET. THIS SHT. I EXIST. CURB & GUTTER EX. A.C. PAVM'T I TO BE REMOVED (4"-5" THICK) S= 3.0% S= 3.0% L_�------ 71T r SAWCUT EX. A.C. - n . " a PAVM'T 1.0' FROM = FACE OF GUTTER FOR CONSTRUCTION BUTT JOINT SECTION A -A N.T.S. 25'-0" TO C/L 3'-0" N.E. 3rd AVE. NEW CURB & EXIST. F/L GUTTER (TYPE A) ELEVATION EXIST. A;EXIST. 4" P.C.0 S=3.33% PAVEMEN CURB & _GUTTER (TYPE "A") W Z J Ir i I FD E-- SIDEWALK 3.0 0/- - III9U -__ L) Elli I 3 CL 'B' A.C. PAVM'T 4" ASPHALT TREATED BASE 4" CRUSHED ROCK(5/8" MINUS) 1'-0" MIN. AT BANK RUN GRAVEL OVER COMPACTED SUBGRADE i SET F/L ELEV. 0.1' LOWER THAN EXIST. ELEV. OF FLOWLINE @ CURB & GUTTER (OPPOSITE SIDE OF TRAFFIC BARRIER) S=3.0%± 0 G 73- CL. "B" A.C. PAVEMENT '+ ASFNAL I I NLA I LU bAJt 4" CRUSHED ROCK (5/8" MINUS) I'-0' MIN. BANK RUN GRAVEL OVER COMPACTED SUBGRADE i SECTION B-B CONC. TRAFFIC BARRIER N.T.S. 3' WIDE CONC. (TYPE "_C_") TRAFFIC BARRIER LJ w bi in, z v OI PLASTIC TRAFFIC BUTTON (TYP.-13 WHITE BUTTONS) SEE DETAIL, THIS 11 2'-1"12'-1" SHEET ! 11 o `° i o I 4" WHITE _ LANE LINE 34" 34" THE 0 PLASTIC TRAFFIC ARROW AND LEGEND. SEE DET., THIS SHEET IC BUTTON & TRAFFIC -ARROW- LOCATION-- DETAIL +I o 9.5"- 10- PLASTIC TRAFFIC ARROWS N.T.S. ALTERNATE I JPP Jpik SLOPE 6:1 1 -'� (TYP.) Note: I. Driveway can ¢e reduced to a thickness o((, 6 when a 10 gage wire mesh 3'squore pattern Is used 2. Where driveway eaeeede 16'ln width a 2" dummy joint shall be placed longitudlnall/ along E. 'ANSION JOINT �4 EXPANSION JOINT (TYP) EXPANSION JOINT (TYP) See 'City Of Renton' Standard VAR. VAR. P Detail For Depressed Driveway E;PA;A)4 Curb 8 Gutter -Type D t0i b SECTION A -A — EXPANSION JOINT ALTERNATE 2. EXPANSION JOINT (TYP.) GENERAL NOTES a�M�ti�THEE'Nrl`NFER. JOINTS JOINTS SHALL BE PLACED AS SHOWN OR AS DIREC CONCRETE CONCRETE SHALL BE CLASS (3/4) AIR ENTRAINED PORTLAND CEMENT CONCRETE.(3DAYb11X) PROCEDURES ALL WORK SHALL BE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS OR AS DIRECTED -RY—Thf -ENGINEER. STD. INDUSTRIAL AND COMMERCIAL DRIVEWAY NTS NTS 6" I 4 D• GENERAL NOTES _I la" sEcr(oN A -A JOINTS: DUMMY JOINTS SHALL BE PLACED NOT TO NTS EXCEED t5' C/C NOR LESS THAN IOC/C CONCRETE: CONCRETE SHALL BE. CLASS A (3/4) AIR ENTRAINED PORTLAND CEMENT CONCRETE CONFORMING TOSECTION 6-02.3 PROCEDURES: ALL WORK SHALL BE IN ACCORDANCE WITH THE PLANS a SPECIFICATION OR AS DIRECTED BYTHE ENGINEER. DEPRESSED CURB AND GUTTER -TYPE "D" CEMENT NTS 48 .75 " TO ARROW 14 15 I _ 3.75' 7- i m'I 3.75 ml F— I �- �.5" t2" 5 -- II 1�94 1- 3.75 3.75' 3.75" 3.75" 3.75" THERMOPLASTIC (WHITE) TRAFFIC ARROW N TS NOTE I. DUMMY JOINTS OF NOT LESS THAN 3/16 THICKNESS SHALL BE OF THE SAME DIMENSIONS AS THE CURB B GUTTER EXCEPT THAT IT SHALL EXTEND ONLY 2-1/4" INTO GUTTER SECTION. 2. SEE CITY OFRENTON STANDARD DETAIL FOR DEPRESSED DRIVEWAY CURB B GUTTER— TYPE D. 3. FORMS SHALL BE TRUE TO LINE 9 GRADE AND SECURELY STAKED. THE"RADIUS ON UPPER FACE OF CURB MAY BE FORMED BY EDGER OR BUILT INTO FACE FORM I" RADIUS ON LOWER FACE OF CURB WILL BE FORMED BY THE FACE FORM, I. LI.IGI� I lVnl. r<C 1 C 18 CLASS B (3/4) JOINTS DUMMY JOINTS SMALL BE PLACED NOT TO EXCEED 15'CiC NOR LESS THAN 10' C/C. THRU JOINTS SHALL BE PLACED AT EVERY OTHER DUMMY JOINT MEASUREMENT, AT POINTS OF TANGENCY ON STREETS, ALLEYS,AND DRIVEWAYS RETURNS. ALL JOINTS SHALL BE CLEAN AND IN THE GUTTER SECTION THEY SHALL BE EDGED. FORMS SHALL BE STEEL FOR STRAIGHT SECTIONS a WOOD FOR CURVED SECTIONS. 1/2"Ri L5-12 I/2 R _ I CONCRETE SHALL BE CEMENT CONCRETE CLASS B (3/4) AIR ENTRAINED PORTLAND CEMENT CONCRETE PROCEDURES FURTHER REQUIREMENTS FOR FORMS, FORM SETTING, PLACING, FINISHING AND •CUR";G SHALL BE AS OUTLINED IN THE SPECIFICATIONS, CONCRETE CURB & GUTTER TYPE "A" NTS 41 - 21I -O \,ro I R. 4 -3 450 R . 3�-3�co THERMOPLASTIC (WHITE) LEGEND DETAIL STD. NTS GENERAL NOTES I. All work materials shall be in conformance with the standards and specifications the City of Renton Utility Department, and the latest edition of the Al'WA Stan- dards and Specifications. �. All locations f o s o existing utilities shown are approximate and it shall be the contr tor's responsibility to verify the true and correct location so as to avoid damage disruption. 3. A preconstruction conference and twenty-four hour notice will be required prior starting new construction. 4. It shall be the contractor's responsibility to secure all necessary permits prior to starting construction. 5. Inspection will be .ccomplished by a representative of the City of Renton. It sh be the contractor's responsibility to notify the Utility Department 24 hours in advance of backfilling all construction. 6. All new asphalt pavement within the public right-of-way shall consist of: -3" (min.) compacted depth Class "B" concrete, over -4" (min.) compacted depth asphalt treated base, over -4" (min.) crushed rock (5/8" minus) compacted to 95% of maximum density p ASTM D-1557, over -12" (min.) bank -run gravel compacted to 95% of maximum density per ASTM D-1557, over - recompacted subgrade to 90% of maximum density per ASTM-1557 Barghausen Consulting Engineers Inc. Land Planning, Survey & Engineering Specialists K25 So 110th $t Sult. 102 KorA. W°.h W32 (206) 872-5522 of ac- or to e all r cn a W J W s F— - +(AW W v = Z Z UJ 0 F- �WZ� LLI k Z > Z CCoate W Z Z a > _ a03 PFCOMMEINDED C) Z W Z W W O DATE✓ 0 CC U. I= 2 L UJ Z En Y a r TT Q Q O � W W Di. T E z Z ♦ W CP to 0 REVISION BY ARCO REVISION- B Y B.C.E. appr 9� STAMP D ATE . R E 'V I S 1 0 N S type date 1101231$7 MODIFY CURB TYPE PER CITY REVIEW S��lB7 Z II MEW P1,),1`pm ,drawn ca 2 III /I 8187! REV. PER CITY REVIEW O prof. sheet Room �FA c, 53G2 C - 5 Ui � V rev. 2 of 5 m y J z 0 O tT7 9 d ®41 O 7�