HomeMy WebLinkAboutSWP3002042.7CN Ln r Y 0 0 Q0 u N 0 STRUCTURE SIZE INVERT ELEVATION CB1 2'-6„X2,-- 10„ 8"S - 13.60 TYPE i C132 2'-6" X2- 10" 8" S - 13.00 TYPE f C133 48" DIA 12" S - 13.09(MATCH EXIST) TYPE 11 12" W - 13.09 CN4 54" DIA 12" S - MATCH EXIST TYPE II 15" E - 12.75 8"N - 13,30 CB-1 72" DIA 15"W - 12.15 TYPE it 24" E - 1 1.40 12" S - MATCH EXIST 8" N - 12.40 CB 48" DIA 14" E - -14.10 TYPE 11 14"N - 14.10 DIVERSION (SEE SHT S503) 24" W - 1 1.30 STRUCTURE 12 E - 12,80 14" W - 14.60 �v 14' W - 14.00 U 27" N - 13.00 WETVAULT (SEE SHT S500) 14"S - 14.00 1 14" E - 14.60(SEE SHT S502) ABANDONED 4' FM 5 18" STS - -- s -- — - HPW---r----- fi AF I w CONSTRUCTION NOTES Q48" DIA TYPE II CATCH BASIN. SEE CITY OF RENTON STANDARD DETAIL .3.2.3. PROVIDE PAVEMENT PATCH PER DETAIL 9/12101. QTYPE I CATCH BASIN. SEE DETAIL 8/C52, AND CITY OF RENTON STANDARD DETAIL 3.2.2. SEE SHEETS C50 AND C51 FOR LOCATIONS. A15" C76 CLASS IV CONCRETE PIPE. MATCH EXISTING PIPE INVERTS AND GRADE. SEE DETAIL 3/C101 FOR CONNECTION TO EXISTING PIPE. 12" C76 CLASS IV CONCRETE PIPE. SEE TABLE FOR INVERT ELEVATIONS, 12" C76 CLASS IV CONCRETE PIPE, MATCH EXISTING PIPE INVERTS I \ AND GRADE. SEE DETAIL 3/C101 FOR CONNECTION TO EXISTING PIPE. 6 14" CLASS 52 DUCTILE IRON PIPE. SEE TABLE FOR INVERT ELEVATIONS. 7 15" C76 CLASS IV CONCRETE PIPE. SEE TABLE FOR INVERT ELEVATIONS. 27" C76 CLASS IV CONCRETE PIPE. SEE DETAIL 10/C101 FOR CONNECTION. 8 AT EXISTING JUNCTION BOX. 9 54' DIA TYPE 11 CATCH BASIN. SEE CITY OF RENTON STANDARD DETAIL 3.2.3. REFER TO SHEET S503 FOR DIVERSION STRUCTURE PLAN AND SECTIONS. -- --------- HPW AF 4" STS _ U- 4-04 BUILDING N WATER VAULT ICf S & C WR - AF 0\ -1 2"STS - `` 12" STS { HPW L L_ 14-17 BUILDING I A Q 0o HPW 0 J, e I ��- STS I i CHWS & R TELEPHONE ,, 9 Q I /� L, / 17-404 BUILDINGcn FM a WOIi VO LTELECT CONDUIT 4-20 BUILDING —18"LISTS STS 1 _-- — _ _ —STS STS Q 10 m Milli wldwl� GM STS CONSTRUCTION NOTES REFER TO SHEETS S500, S501, AND S502 FOR WETVAULT PLAN AND 1 SECTIONS. A 48" DIA TYPE 11 CATCH BASIN. SEE CITY OF RENTON STANDARD ' DETAIL A 8" CLASS III CONCRETE PIPE. SEE TABLE FOR INVERT ELEVATIONS. A4 TYPE 1 CATCH BASIN. SEE DETAILS 8/C52, 6/C101, AND CITY OF RENTON STANDARD DETAIL 3.2.2. CONNECT WITH CLASS III 8" CONC PIPE TO STORM DRAIN. SEE SHEETS C50 AND C51 FOR LOCATIONS. A8" CLASS 52 DUCTILE IRON PIPE. MATCH EXISTING INVERT ELEVATION ATEXISTING CATCH BASIN. SLOPE 0.2% MINIMUM TO NEW TYPE II CATCH BASIN, PROVIDE PAVEMENT PATCH PER DETAIL 9/C101. QSEE DETAIL 10/C52 FOR CONCRETE ENCASEMENT OF 8" AIR LINE. f� 48" DIA TYPE 11 CATCH BASIN WITH SLIDE GATE AND 24-INCH f� DIAMETER NON -LOCKING LID. SEE DETAIL 6/S503. 72" DIA T)`PE 11 CATCH BASIN WITH 24" DIAMETER NON -LOCKING I LID. SEE CITY OF RENTON STANDARD DETAILS 3.2.3 AND 3.6.7. GENERAL NOTES 1. SEE: GENERAL NOTES 1,2,3, & 4 ON C20. 2, ANY CONFLICTS BETWEEN PAVING ELEVATIONS AND PIPE INVERT ELEVATIONS SHALL BE IMMEDIATLY REPORTED TO THE CONSTRUCTION ENGINEER. 3. SHORT LENGTHS OF THE HIGH PRESSURE WATER MAIN SHALL BE SHUT DOWN BETWEEN SECTION VALVES DURING CONSTRUCTION OF ADJACENT STORM DRAINS. COORDINATE WITH BOEING FIRE PROTECTION. 4, CONTRACTOR SHALL IMMEDIATLY NOTIFY BOEING CONSTRUCTION ENGINEER IF 18-INCHES MINIMUM COVER CANNOT BE MAINTAINED OVER TOP OF NEW STORM DRAIN OR WHERE NEW STORM DRAIN PIPE SLOPE IS LESS -THAN 0.2%. 5. WETVAULT DESIGN CRITERIA: TRIBUTARY DRAINAGE AREA: 11.78 ACRES WETVAULT SURFACE AREA: 5510 SF± DESIGN FLOW: 1.37 CFS (1 /3 OF 2--YR STORM) 150 _ EXISTING 18" RCP STORM DRAIN Q CAPPED EACH SIDE OF EXIST CEM CONC PVMT. PROTECT 5 a DURING CONSTRUCTION z HPW 10" wwP 8" STS _ 2 - 8" STS 2 - 8" STS - - - - --- - STS - - STS - -- �� r -12"STS AF I I AF— ------ ; --- - AF -HPW A 12 11 STS - H P4- G M --- - J -0 I I - i NEW 8" AIR LINE FOR FUTURE y 3 < 1 101' [---REPLACE 8" HPW I 5 4 I I All Q - lrsrs 15' STS A-mlI 300' I 12" STS --- -- ----- - 12" STS - ABANDONDED 4"FM - 10" H PW --------- -- -- - - - ------------------- HPW --- -- ---- ----- - - - - - 4-81 BUILDING LEGEND PROPOSED EXISTING --- A -- COMPRESSED AIR N----- O MANHOLE AF- AUXILARY FIRE -- CHWS &R - CHILLED WATER SUPPLY AND t� VALVE RETURN - FM --- FORCEMAIN 40' 0 40' 80' ■ ❑ TYPE 1 CATCH BASIN ----- SS SANITARY SEWER GRAPHIC SCALE @O MONITORING WELL HPW HIGH PRESSURE WATER ---- STS ------ STORM DRAIN FIRE HYDRANT ---GM------ GRAVITY MAIN BURIED UTILITY PIPING AS NOTED • TYPE II CATCH BASIN 18" STS 12" STS -f FM ARB %LVW LT STS HPW 15" STS 12" STS 2,CSTS 12"ST! 15" STS ,o, A EXISTING JUNCTION BOX Idol YY LLL MONITOR WELL TO 8 � �n DIVERSION REMAIN PROTECT V) ' STRUCTUREA DURING CONSTRUCTION o CB3 4 10" HPW EXISTING JUNCTION BOX 33" STS 5 W ----- WATER P POWER C ---- COMMUNICATION7 D o 0/v 1 ; ,'RECOPQ DRAWING` � CITY OF RENTOT4 I KRAMER, CHIN & MAY0 CONSULTING ENGINEERS DEPARTMENT OF PUBLIC WORKS RASED ON' INFORMATION FURNISH'L Y THE corrT�,Acr. ( UTILITIES FLAN - 8Y C -ATE r p ..._..... .� •- r ,5 �1 !l I T) A T�7TTTATf-4 A T7T1 A w 0 O b o z w o O�y C H wp - 3o -?a4?