HomeMy WebLinkAboutSWP1002051.2ABBREVIATIONS SENERAL NOTES I L E G E N D
ALTERNATE
ALT.
;AMERICAN NATIONAL STANDARDS INSTITIUTE
ANSI
AMERICAN PUBLIC WORKS ASSOCIATION
APWA
AMERICAN RAILWAY ENGINEERING ASSOCIATION
A.R.E.A.
BOULEVARD
BLVD.
BUILDING
BLDG.
CATCH BASIN
CB
CENTERLINE
IL
CLEAN OUT
CO
CLEARANCE
CLR.
CONCRETE
CONC.
CONCRETE MASONRY UNIT
C M U
CONSTRUCTION
CONSTR.
DEPARTMENT
DEPT.
DIAMETER
CIA.
DRAWING
DWG.
EAST
ELEVATION
EQUAL
ETCETERA
OTC.
EXISTING
EXIST.
EXPANSION
EXP.
FIRE HYDRANT
FH
-IRE WATER
-
TOOT
lT.
GRAVEL
GRAV.
NVERT ELEVATION
-r
MANHOLE
'MH
MONUMENT
MON.
NORTH
N
NOT TO SCALE
ITS
NUMBER
NO.
PAVEMENT
PVMT.
POUNDS PER SQUARE INCH
PSI
POWER POLE
PP
PRIVATE SANITARY SEWER
PSS
RADIUS
R.
RAILROAD
RR
REQUIRED
REQ'D.
SANITARY SEWER
SS
SANITARY SEWER FORCE MAIN
SS FM
SCHEDULE
SCH.
SECTION
SEC.
SHEET
SHT.
SPACE
SP.
SPECIFICATIONS
SPECS.
STANDARD
STD.
STANDARD DIMENSION RATIO
SDR
STORM DRAIN
SD
TELEPHONE
TEL.
TEMPORARY
TEMP.
TOP OF CURB
T/C
TOP OF FRAME
T/F
TOP OF PAVEMENT
T/P
TOP OF VAULT
T/V
TYPICAL
TYP.
AASHINGTON INDUSTRIAL
SAFETY AND HEALTH ADMINISTRATION
WISHA
KITH
w/
THE FOLLOWING APPLY UNLESS OTHERWISE INDICATED
'_. LOCATIONS OF EXISTING UTILITIES ARE APPROXIMATE. T SHALL
OE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE TRUE LOCATIONS
AND ELEVATIONS SO AS TO AVOID DAMAGE OR DISTURBANCE DURING CONSTRUCTION.
. CALL (1-800-424-5555) FOR UTILITY LOCATIONS (WATER, SANITARY SEWER, STORM
`WER. GAS, POWER, TELEPHONE AND TELEVISION).
DURING CONSTRUCTION, CONTRACTOR SHALL BE REQUIRED TO CONTROL ON SITE
'TORM WATER RUNOFF BY USING TEMPORARY EROSION/SILTATION
CONTROL PROCEDURES. NO SEDIMENT LADEN STORM WATER SHALL BE ALLOWED
-0 DISCHARGE INTO THE CITY OF RENTON'S STORM DRAINAGE SYSTEM,
JR ONTO ADJACENT PROPERTIES.
+. DURING CONSTRUCTION, ALL STREETS, PUBLIC OR PRIVATE, ADJACENT TO
THIS PROJECT SHALL BE KEPT CLEAN OF ALL MATERIAL DEPOSITS RESULTING FROM
JN SITE CONSTRUCTION, AS DIRECTED BY THE CITY.
-HE CONTRACTOR AT ALL TIMES SHALL FOLLOW ALL STATE .AND LOCAL SAFETY
'EQUIREMENTS DURING CONSTRUCTION OF THIS PROJECT. SPECIAL CARE SHALL BE TAKEN
DURING ALL TRENCHING OPERATIONS. SHEETING AND BRACING. CRIBBING, ETC., 'y1UST
E INSTALLED AS REQUIRED TO PROVIDE MAXIMUM SAFETY TO THE CONTRACTOR'S
�iORKERS IN FULL COMPLIANCE WITH WISHA REGULATIONS.
S. AHERE MORE THAN ONE STANDARD IS REFERENCED ON THE DRAWINGS
R IN THE SPECIFICATIONS AND THERE IS A DISCREPANCY BETWEEN
THE TWO THE MORE STRINGENT SHALL APPLY.
7. STANDARD DETAILS FROM THE LATEST REVISION OF THE CITY OF RENTON
"!TILITY ENGINEERING STANDARD DETAILS."
8. PATCH OR REPAIR PUBLIC SIDEWALKS, CURBS, STRIPING, AND ROADWAYS PER APPLICABLE
�iTY OF RENTON STANDARD DETAILS AND SPECIFICATIONS. PATCH ROADWAY PER 6
C-9
9. PATCH OR REPAIR PAVEMENTS WITHIN DRAINAGE AND CONSTRUCTION EASEMENT PER 3
C-9
STORM WATER DRAINAGE NOTES
I. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -
CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER.
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON
STANDARD SPECIFICATIONS FOR MUNICIPAL CONSTRUCTION.
3. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE
APPROVED PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC
WORKS. ANY DEVIATING FROM THE APPROVED PLANS WILL REQUIRE
VRITTEN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF PUBLIC
WORKS, DESIGN ENGINEER OR STORM WATER UTILITY.
A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER
ONSTRUCTION IS IN PROGRESS.
D. DATUM SHALL BE U.S.G.S. UNLESS OTHERWISE APPROVED BY CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS. REFERENCE BENCHMARK AND ELEVATION
ARE NOTED ON THE PLANS.
o. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO
:LEAKING AND CONSTRUCTION, AND THEY MUST BE SATISFACTORILY
�;1AINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE
POTENTIAL FOR ON -SITE EROSION HAS PASSED.
?. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE,
OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE
SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE
DEPARTMENT OF PUBLIC 'WORKS, STORM WATER UTILITY.
8. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED
FOUNDATION IN ACCORDANCE WITH SECTION 7-02.1(1) OF THE CURRENT
STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE
:"INSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH
30TTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS
PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO
JNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
lUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. ALL PIPE BEDDING
--HALL BE ,AS SHOWN ON PLANS.
?. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT
-EVEL IN PAVED AREAS AND 6" ABOVE GRADE IN ALL OTHER .AREAS.
10. OPEN CUT ROAD CROSSINGS THRU EXISTING PUBLIC RIGHT-OF-WAY WILL NOT
BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER.
ISSUANCE OF THE BUiLDING OR CONSTRUCTION PERMIT BY THE CITY OF
ENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL
'BLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER
C',ISPOSITION. FURTHER, -HE CITY OF RENTON DOES NOT ACCEPT ANY
OBLIGATION FOR THE PPOPER FUNCTIONING AND MAINTENANCE OF THE
SYSTEM PROVIDED DURING CONSTRUCTION.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE
SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY
ETHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE
PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE
ERFORMANCE OF 'WORK COVERED BY THE CONTRACT. ANY WORK WITHIN
THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW
SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE TRAFFIC
,ENGINEERING DIVISION OF THE DEPARTMENT OF PUBLIC WORKS. ALL
SECTIONS OF THE W.S.D.O.T, STANDARD SPECIFICATION 1-07-13, ;RAFFIC
CONTROL, SHALL APPLY.
13. PIPE SHALL BE REINFORCED CONCRETE (RCP) WITH RUBBER GASKETED JOINTS
:DER ASTM C76, CLASS-
'4. MAN HOLES TO BE 120 INCH DIAMETER WITH SOLID LOCKING LID.
EE FOR DETAILS.
6. FIELD VERIFY LOCATION AND INVERTS OF ALL CONNECTIONS TO
=XISTING STORM DRAINS PRIOR TO CONSTRUCTION. IMMEDIATELY
NOTIFY ENGINEER OF ALL DISCREPENCIES.
'S. TRENCH SHORING DESIGN BY CONTRACTOR.
TEMPORARY EROSION/SEDIMENTATION CONTROL NOTES
BEFORE ANY CONSTRUCTION ACTIVITY OCCURS, A PRE -CONSTRUCTION
!MEETING MUST BE HELD WITH THE CITY OF RENTON DEPARTMENT OF PUBLIC
+ORKS DESIGN ENGINEER.
2. PROVIDE SILT FENCE AROUND PERIMETER OF TRENCH EXCAVATIONS.
-ONSTRUCT SILT FENCE PER THE CITY OF RENTON STANDARD PLAN SHEET 4.1.
. THE TEMPORARY EROSION CONTROL SYSTEM SHALL BE INSTALLED PRIOR TO
ALL OTHER CONSTRUCTION.
4. 'MAINTAIN NATURAL VEGETATION OUTSIDE OF IMMEDIATE CONSTRUCTION
.;REAS FOR SILT CONTROL.
5. AS CONSTRUCTION PROGRESSES AND SEASONAL CONDITIONS DICTATE, THE
'OSION CONTROL FACILITIES SHALL BE MAINTAINED AND/OR ALTERED AS
,SQUIRED BY THE CITY OF RENTON TO ENSURE CONTINUING
ROSION/SEDIMENTATION CONTROL.
o. ;ALL TEMPORARY SILTATION CONTROLS SHALL BE MAINTAINED
N A SATISFACTORY CONDITION UNTIL SUCH TIME THAT
-LEARING AND/OR CONSTRUCTION IS COMPLETED, PERMANENT
71RAINAGE FACILITIES ARE OPERATIONAL, AND THE POTENTIAL FOR EROSION
SAS PASSED.
7. THE PUBLIC RIGHT-OF-WAY SHALL BE KEPT CLEAN. TRACKING OF MUD AND
DEBRIS FROM THE SITE WILL NOT BE ALLOWED. FAILURE TO COMPLY WITH
THIS CONDITION WILL RESULT IN ALL WORK ON THE SITE BEING STOPPED.
8. CATCH BASINS/INLETS WITHIN CONSTRUCTION AREAS SHALL BE PROTECTED
PER THE CITY OF RENTON STANDARD PLAN SHEET 4.1.
9. ALL LIMITS OF CLEARING/STRIPING AND AREAS OF VEGETATION PRESERVATION
AS SHOWN ON THE PLAN SHALL BE CLEARLY FLAGGED IN THE FIELD
,ND OBSERVED DURING CONSTRUCTION.
J. TRENCH EXCAVATIONS ARE TO BE BACKFILLED TO MATCH EXISTING GRADE
�T THE END OF EACH DAY. THE TOP 6 INCHES OF FILL SHALL BE CRUSHED
SRAVEL SURFACING.
DESCRIPTION VEW EXISTING I
BUILDING
CONCRETE L
ASPHALT
so
STORM DRAIN SD — — — — —
SS :s
SANITARY SEWER — — — — - — — — --
DOMESTIC WATER <'_8110 — — — —
NATURAL GAS
TELEPHONE TEL
ELECTRIC DUCT L
I MANHOLE
CATCH BASIN _
FIRE HYDRANT
THRUST BLOCK
POWER POLE -
i I T( I IT n O i r
ELEVATION
1)0.00
FENCE
x—X—x—x—x—
SILTATION FENCE
x x x— x x x—
DITCH OR SCALE
CONTOUR LINE
/� 0000
CLEAN OUT
CO
WATER GATE VALVE
I w/sox
w6v
KEY OPERATED VALVE
w/BOX
SURVEY CONTROL POINT
PROPERTY LINE
------_-----
RIGHT OF WAY
i
I RAILROAD
1
DITCH CENTERLINE
j EASEMENT
Of v
_ SfONAI.Y'`'7
j SSOE, INC.
i
ENGINEERS ARCHITECTS PLANNERS
3015 112TH AVENUE. N.E., SUITE 101
BELLEVUE. WASHINGTON 98004 TEL. 206-827-2950
PROJECT
NUMBER zISOil- O3
DRAWING 2
NUMBER
—!TY OF RENTON
DEPARTMENT OF PUBLIC 'NORKS
SHEET 1
I F
ENERAL NOTES, ABBREVIATIONS
' AND LEGEND
S WAD -,*a - lob Av
0 - S- Z
0 ISSUE FOR BID SWT
NO. REVISION BY
DESIGNED: S.
174 Z DRAWN:
6/ 10/92 CHECKED:
APPR. DATE APPROVED:
`\ / , /�
p S-/ i
W.
DATE: 02/28/92 FILE NAME: 1 103C2
-,GALE: NOTED
-;RECTOR OF PUBLIC WORKS
=DLO BOOK:-- 'AGr✓
HEET: L F: