Loading...
HomeMy WebLinkAboutSWP3002070.330'0 NEW DOUBLE -WALL STEEL TANK TO BE ERECTED ON SAME CENTER POINT AS REMOVED TANK n O r� m 0 n 0 z n m -4 rrt F_ 0 X • X I X • X X X X X X x O W Q U SYM I REVISION rn REVISIONS PER BOEING REVIEW COMM rn * 01 JUN 92 AND HART CROWSER FINA REVISIONS PER CITY OF RENTON REVI OF 21 AUG 92 w REVISIONS PER CITY OF RENTON REVI OF OCT 92 3 0 00 1 'swP an TO -2070 05 SE 53 SEE NOTE 3 22.0 w w w z z 0 Q 20.0 w J w i j 14.0 u I 2'� CB CB SEE NOTE 8 2"0 BLACK STEEL CONDENSATE DISCHARGE LINE / NEW CONDENSATE / COOLER ------- CATCH BASIN - TYPE I TOP EL. 23.9 6" INV. N 21.04 BOTTOM 20.0± SEE NOTE 2 NEW CONCRETE UTILIDOR '7",A QI Ary QTCCI UTILITY PLAN SCALE 1 "-10 CATCH BASIN - TYPE I TOP EL. 23.9 8" INV. N 20.87 6"' INV. S 20.89 6" INV. W 20.90 BOTTOM EL. 19.9 ± SEE NOTE 2 15' CONTRACTOR SHALL EXPOSE AND VERIFY GRADE AND CONDITION OF EXISTING UTILIDOR. CONTRACTOR TO DESIGN CONNECTION BETWEEN NEW AND EXISTING UTILIDORS AND SUBMIT TO OWNER FOR APPROVAL PRIOR TO CONSTRUCTION. N 0 10 20 SCALE IN FEET EXISTING CONCRETE UTILIDOR NEW RAMP SEE DETAIL L ON DRAWING C5 METAL FRAME AND GRATE STD. PLAN B-2 OF WSDOT. (TYP.) 26.0 CATCH BASIN TYPE I MEETING STD. PLAN B-1 OF WSDOT. (TYP.) 24 (30"x34"x60"H MAX.) RON STORM LINE 705 CATCH BASIN - TYPE I TOP EL. 24.7 8" INV. W 20.52 8" INV. S 20.54 BOTTOM 19.5± SEE NOTE 2 16.0 14.0 PROFILE - STORM DRAIN AND CATCH BY PPROVED DAT- SYM REVISION JD/JH MJB 04 JUN 92 MENTS JD/JH MJB 21 AUG 92 MENTS JD/JH MJB 14 OCT 92 BY WPPROVELI DATE BAS-INS__- F C3 C3 ❑ AUBURN, WA. 98002 ❑ EVERETT) WA, 98201 El KENT) WA. 9eo3l o ZVZ�Fgz�yo ❑ PORTLAND) OR. 97220 FACILITIES DEPARTMENT RENTON) WA. 98055 ❑ SEATTLE, WA. 98124 11'-2" PLAN - OIL/WATER SEPARATOR - N co EL 22.40 i� FLOW DIFFUSER BAFFLE OIL RETENTION BAFFLE SLUDGE WEIR NOTES: 1. OIL/WATER SEPARATOR SHALL BE PIPE INC. MODEL NO. 5106-5 MODIFIED OR APRROVED EQUAL. SECTION - OIL/WATER SEPARATOR .1 NOTES: 1. GROUNDWATER AT THIS SITE FLUCTUATES BETWEEN ELEVATION 19 AND 17 FEET. CONTRACTOR MAY HAVE TO DEWATER SOME EXCAVATIONS DURING CONSTRUCTION. 2. FINISHED GRADE OF CATCH BASINS AND INLETS SHALL BE ADJUSTED TO POSITIVELY DRAIN THE PAVEMENT AREAS. 3. BENCHMARK 53, TOP OF ASPHALT SURFACE AT SOUTHEAST CORNER OF PROJECT SITE. EL. = 24.76 FEET. C* 4. INSTALL NEW 6" DRAIN WITH REMOVABLE GRATING IN CONCRETE FUEL CONTAINMENT AREA. DRAIN TO COMPLY WITH STD. PLAN B-4 OF WSDOT, OR APPROVED EQUAL. 5. PLACE AND COMPACT HOT ASPHALTIC CONCRETE IN THIS AREA TO FACILITATE DRAINAGE OF STORM WATER RUNOFF TO CATCH BASIN. 6. ALL CAST IRON PIPE STORM LINES SHALL HAVE MINIMUM WALL THICKNESS PER A.W.W.A. CLASS 22. 7. REMOVED PORTION OF CONCRETE DIKE CONTAINMENT WALL SHALL NOT BE RECONSTRUCTED AT CONCLUSION OF PROJECT. �3> 8. SLOPE GROUND SURFACE INSIDE EXISTING CONTAINMET TO DRAIN AT 17. TYPICAL TOWARDS CATCH BASIN. NEW CATCH BASIN ELEVATION 23.6 FEET, PIPE INVERT ELEVATION 21.05 FEET, BOTTOM OF CATCH BASIN AT 20.0 FEET. Cvns ftic fed_ No 4r RECOMMENDED FOR APPRVAL BYiAJJT-- D, w2O7O Jc R ��► Lr w,flreR RECOMMENDED FOR APPROVALPLARTOWWSM Y BY RZ.,4A feVIA /o-z3-9Zr 5/19/92 DRAWN Y DATE SUBTITL7 ACCEPTABILITY LAST REVISION SYM DATE THIS DESIGN AND/OR CHECKED EJC s 92 UTILITY PLAN AND DETAILS SHEET 3 PECIFICATION IS APPROVED JAH 5/7/92 _ C;3 OF CHECKED -- 5 - - APPROVED BY DEPT. DATE ENGINEERED BY TITLE JAH s 92 FUEL STORAGE REPLACEMENT SLG s 92 FOR ARE-129 JOB NO �COIVIP,NO, R❑VED 305355 FU-DWG: RENTON FACILITY DWG, NO, Ar ED BLDG 4-89 RLNTON 304-089-1002