HomeMy WebLinkAboutTED4002159.1I.E. = 130.27'
I,;-_ , 129.10'
I.E. =
SYM REVISION
0 REVISE SITE LAYOUT
1 ISSUE FOR CONSTRUCTIOl�
I j I
I I I
I -
co
I
I w
i
I cu
I -
o
i •
0
0
! c
i
I
i
I
i SAWCUT AND REMOVE EXISTING PAVEMENT.
I I O REPLACE WITH 3" CLASS B ASPHALT AND
I j 4' OF 5/8' MINUS CRUSHED ROCK.
QUALITY TO MATCH EXISTING.
I w
s
CB TYPE 1
ol
RIM = MATCH EXISTING -0.1'
I i
I.E. 8" W = 132.80'
I I I.E. 8' E = 132.90'
i j �Q zl
1 1 cn oo l I
_ I I
v ; 00 1 i 80 LF 8" CMP ® 0.30 FT/FT
I i
I I 1
N90'00'00"W 115.09'
! SD SID
SS co -.w- ----
--------------
j -E--
I I
j I I DOUBLE DETECTOR CHECK
W I I N i o VALUE DRAIN — — — — — — —
:3 I I 1
I
1 1 I I I CAP AND PLUG EXISTING WATER SUPPLY,
U i i I REMOVE METER AND METER BOX.
I H
LOT 3
—
lFLOOR DRAIN
I i I
1 i 4' DOUBLE DETECTOR
j o I I CHECK VALUE
j n I 1 I W/ VAULT (TYP)
I I II
I , i
I I I -Ln
i
of 1 1 /2" U. (TYP
I !
—
1 I I 4' DI
--I— W---i---- FH oLn
CD
ch
I o
I
! I I I
' I I TOP
� I
I LOT 4
I
I I
j 1 I l I I I FLOOR DRAIN
w
> W I L I >il
a I I i a� I I
w I �I
CD ( I I I I �
o I{ I I o 1 o I
Ln� I
� I I
I I I
j w 1
I I
aus
U �—
! ~ ( 80LF 8" CMP 0 0.30FFT T ss— T co
H SD
1
mkr S90'00'00"E 115.09'
f i I
m
I a I I
1 1 I I I CB TYPE 1
I I I I RIM = MATCH EXISTING —0.1'
I I ( I.E. 8" W = 136.80'
I i i i I.E. 8" E= 136.90'
, I
I.E. = 133,98'
I
I I w
3: I �' Z I SAWCUT AND REMOVE EXISTING PAVEMENT.
o I REPLACE WITH 3" CLASS B ASPHALT AND
4 OF 5/8' MINUS CRUSHED ROCK.
oo l w QUALITY TO MATCH EXISTING.
O CD j l
ZI
ml
oI
I I �
i >
I
BY APPRO`/ED DATE SYM REVISION BY APPROVED DATE
JLN 16/'I 1 /94
CB TYPE 1
RIM = 160.00'
I.E. 8' W 156.80'
I.E. 8' S = 156.90'
r-
In
0
(ALL!
rn
I
I
I
I
I
I AR EA I N LET
I RIM = 169.50'
I.E. 8' N = 167.70'
AREA INLET
I RIM = 170.50'
1.E. 8" S = 167.47'
I �
to
o
0
I a
I
_vim I
TELEPHONE
RISER —
CB TYPE 1
RIM = 163.00'
I.E. 8" W = 160.80'
I.E. 8" N = 160.90'
N
0
0
u-)
N
O
0
Lo
NICLAS ENGINEERING
1310 S.W. 172ND STREET
SEATTLE, WASHINGTON 98166
(206) 244-6940
0
0
0
3
0
0
0
0
0
Z
ABBREVIATIONS
CB
CATC H BAS I N
CMP
CORRUGATED METAL PIPE
CU
COPPER
DI
DUCTILE IRON PIPE
IE
INVERT ELEVATION
PVC
POLYVINYL CHLORIDE PIPE
SSMH
SANITARY SEWER MANHOLE
T
_ z\�
DRAWN BY
JLN
D TE
6911/94
CHECKED
ENGINEER
JLN
6/11/94
CHECKED
APPROVED
2656� 4
b'jv ..�
�Ir,NAl_ �
APPROVED
CONSTRUCTION NOTES
1. INSTALL PRESSURE REDUCING VALVES AND DOUBLE
CHECK VALVES ON THE DOMESTIC WATER SERVICE.
2. INSTALL THE 1-1 /2" DOMESTIC SERVICE PER CITY
OF RENTON STANDARD DETAIL BR42.
3. THE CONTRACTOR SHALL SUBMIT A SCHEDULE FOR
CONSTRUCTION WHICH SHALL INCLUDE ALL EROSION CONTROL
MEASURES TO BE USED TO PROTECT THE SITE :AND
DOWNSTREAM, INCLUDING BUT NOT LIMITED TO:
CATCH BASIN SILT PROTECTION, DUST CONTROL,
STREET CLEANING, AND SILT FENCING. THE PROPOSED
CONSTRUCTION ACCESS LOCATION SHALL BE INDICATED.
4. INSTALL FILTER FABRIC FENCE PER KING
COUNTY SURFACE WATER DESIGN MANUAL, FIGURE 5.4.4F.
5. PAVEMENT SHALL BE RESTORED TO MATCHING EXISTING.
NEW
EXISTING
•
• CO
— — —
D FH
O
G—
--- G----
SS
---SS---
SD
---SD---
W-
---W---
GRADY KEMP
AREA INLET
CATC H BAS I N
CLEAN OUT
FIRE HYDRANT
FOUNDATION DRAIN, 4' PERF
MANHOLE
NATO RAL GAS
SANITARY SEWER
STORM DRAIN
WATER
WATER METER
�OMb1ENDE,� �oFx. ApPaovAc.
GRAPHIC SCALE 1'=10'
�� .
0 10 20 30
quo 7,
Ifta.4
)9
SCALE 1"=10' 6/11/94
APARTMENT COMPLEX SHEET
c 1
UTILITY PLAN
J03 NUMB
93038E
DRAWING NUMBER
�
=gam
E. It> ftwp� %A `. T.,