Loading...
HomeMy WebLinkAboutTED4002164.2PIPE 12" MIN. PLAN 6" �n COUPLING --' -) CMP OR CPEP SMOOTH INTERIOR DATUM ELEV 100.00 COREY TYPE FIRE HYDRANT EQUAL TO I❑WA F-5110 AS SHOWN OR APPROVED EQUAL 6" MECHANICAL JOINT INLET WITH LUGS, 5-1/4" MAIN VALVE OPENING, TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS, 4" PUMPER CONNECTION CITY OF SEATTLE THREADS, 1-1/4' PENTAGON OPERATING NUT, FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT, PRESERVATIVE PAINT No, 43-114, INTERNATIONAL YELLOW OR APPROVED EQUAL, PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY FOR 4-1/2' TRENCH, FIRE HYDRANT EXTENTI❑N TO BE USED IF REQUIRED, NOTE; 1, This debris barrier is for use outside roadways on pipes 36' dia, and smaller, See Figure 4,3,4H for debris barriers on pipes projecting from driveway or roadway sideslopes, 2. All steel parts must be galvanized and asphalt coated (Treatment 1 or better), 3. CPEP-smooth interior pipe requires bolts to secure debris barrier to pipe, 3/4' DIA, SMOOTH BAR L__ 4" MAX. (TYP) END VIEW SPOT WELD BARS TO AT LEAST 2 CORREGATI❑NS OF METAL PIPE (TYP) BOLT TO CPEP SMOOTH INTERIOR PIPE, SIDE VIEW * • I] 0000 O W J W 00 O to m DEBRIS BARRIER N 0 w 0 W 0 Cif Q z I oz2 �1--zP0 LLJ V)DN� N FwN OZN m7) L`"z0 �0 I-Q w =Owz �F-LL-wwo V) W(nOZ Z0 D D t>w�0 w Q Q U�10.�� +1.57 a NO SCALE UN 100' YMETRICAL VC U')M O It A d' tM J O N r- r r LD H J U LO LO J W p J W 00 LO 00 + o WQII O W cn o -i II N - U CL PQ Q W i i U _ GROVNo EX� ,NE CB 8, TYPE I RIM = 117.54 INV.=114.64 (12") INV.=114.74 (6") 1+00 S.E. 194TH CT. HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 10' F- U MAX 4, MIN 2' CONCRETE BLOCKING L. » J 12 � 16' x 8" x 4" MININUM CONCRETE BLOCK 18" TO 20" 07• RAISED PAVEMENT MARKER TYPE 88 A8 STIMS❑NITE TWO-WAY BLUE, TWO-PIECE CAST IRON VALVE BOX, EQUAL TO ❑LYMIC FOUNDRY CO, STANDARD 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT, 1�1 goo CONCRETE BLOCKING EXISTING 16' D,I, MAIN CAST IRON TEE, WITH 6" FLANGE SIDE OUTLET (16" x 6" WET TAP), 6" GATE VALVE (FL X MJ) EQUAL TO MUELLER CO, A-2380-16 6" DUCTILE IRON PIPE, CLASS S2 CEMENT LINED, LENGTH TO FIT TWO 3/4' STEEL TIE RODS, SEE STD DETAIL FOR TIE RODS, 7 CU, FT, MINIMUM WASHED GRAVEL PASSING 1-1/2' AND RETIANED ON 1/4' MESH FOR DRAIN, FIRE HYDRANT ASSEMBLY LEVEL ALL GROUND MIN 3' RADIUS ONE MAN ROCK ° 1 --, -rtJ 6 '1 FILL 1 06 HYDRANT LOCATION IN CUT OR FILL � 0) _J m� r HYDRANT ASSEMBLY M m NO SCALE � J to0W + O W Q Q / N P� 005�o�R �,0•�3/ 2+00 CUT CONCEPT ENGINEERING, INC. 455 Rainier Boulevard North, Suite 200 Issaquah, Washington 98027 (206) 392-8055 OUND S