Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutWTR2702181.14T_
00
I
N
rn
0
o
0
� W
� a
o I
U ry
L>L~
I—
W
W
U
Q
o
Z
Q
� W
o
z(J-)
Q D
O
w
wQ
F
V)
� W
U
zu�
T
� �
w
O
a
z
L
W
a
O
0
a
� o
0
a
O O
E
o 'E-
W
�w
n-
Gj
i---1
_
'�'c
U)
p
E
o
O
d
= Nc
.� cCC
� E
HIV
C
sj))
a �
L �_
CD
w
J
=�
U
= z
Q
cn
U
z
Nzo
V)
W
:� O U
28
O
o
tzZ
Z
a�U
v)
0
w
Q
o
Q
oa
oQ
Q
s�
W
W
W
z
Z
3
Y
w
O
n
O
a
(7/7
O
U
Q
w
Q
I
z
O
cn
w
ry
SAWCUT FINAL JOINT
TYP. EACH SIDE
EXIST. ASPH. CONC. PAVEMENT, TYP.
E
12" 6" CL 'B' ASPHALT CONCRETE PATCH
TYP (2 LIFTS)
6" CRUSHED SURFACING TOP COURSE
TRENCH
SUBSEQUENT BACKFILL
(SEE BEDDING/BACKFILL DETAIL)
PAY LIMIT OF TRENCH
PATCH PAYMENT
5-0" FOR MAINLINE
3'-0" FOR WATER SERVICES & HYDRANT LATERALS
ASPHALT CONCRETE PAVEMENT
RESTORATION DETAIL
NOT TO SCALE
S. 2ND ST. FROM BURNETT AVE S. TO WHITWORTH AVE S.
(EXCEPT AT STREET INTERSECTIONS WITH LOGAN AVE S., MORRIS AVE S.
AND WHITWORTH AVE S.)
LOGAN AVE. SO. FROM SO. 2ND ST. TO SO. 3RD ST.
CONSTRUCTION SURVEY NOTES
DATUM: CITY OF RENTON SURVEY CONTROL NETWORK-NAVD 1988,
AS ESTABLISHED BY TRIAD ASSOC. FOR THE CITY OF RENTON.
MERIDIAN: CITY OF RENTON SURVEY CONTROL NETWORK-NAD 1983/1991,
WASHINGTON COORDINATE SYSTEM OF 1983/1991, NORTH ZONE.
CONTROLLING BENCHMARKS:
NO. 2123 NGS BRASS DISC "Q462 1973"-ELEV.=13.750 M OR 45.111 FT.
NO. 673 TOP OF CASED MON. 12,N. OF INT. OF MORRIS AVE. S. & S.2ND ST.
ELEV.= 9.943 M OR 32.621 FT.
EXISTING UTILITY NOTES
A.) POWER, TELEPHONE, GAS, SEATTLE WATER, AND CABLE: EXISTING UTILITY LOCATIONS ARE SHOWN ON
THE PLANS FOR THE CONTRACTOR'S INFORMATION. LOCATIONS OF THESE UTILITIES ARE APPROXIMATE AND
ARE BASED ON RECORDS SUPPLIED BY EACH UTILITY. THE DEPTH OF EACH OF THESE UTILITIES IS SHOWN
ON THE PROFILE AND IS BASED ON TYPICAL LAYERING DEPTHS FOR EACH OF THESE UTILITIES. HOWEVER,
THE ACTUAL DEPTH IS UNKNOWN AND WILL VARY SIGNIFICANTLY.
B.) SANITARY AND STORM SEWERS: THE EXISTING SANITARY SEWER LINES AND SIDE SEWERS STUBS AND
STORM SEWERS AS SHOWN ON THE PLANS ARE APPROXIMATE AND BASED ON AVAILABLE SIDE SEWER RECORDS.
LOCATIONS OF CROSSINGS IDENTIFIED ON THE PLANS ARE BASED ON NEARBY SEWER FACILITIES AND AN
ASSUMED SLOPE.
C.) UTILITY CONFLICT WHICH MAY OCCUR DURING CONSTRUCTION SHALL BE RESOLVED IN THE FOLLOWING MANNER:
IF THE PROPOSED 12" WATER MAIN CONFLICT WITH ANY UTILITY, THE WATER MAIN WILL BE DEFLECTED AT THE JOINTS
TO GO UNDER THE CONFLICTING UTILITY. IF JOINT DEFLECTION CANNOT BE USED, VERTICAL BENDS WITH BLOCKING
AND RESTRAINED RODS SHALL BE USED TO LOWER THE WATER UNDER THE CONFLICTING UTILITY, WITH A MINIMUM OF
6" VERTICAL CLEARANCE. INSTALL 6" ETHAFOAM PAD BETWEEN THE PIPES.
D.) THE CONTRACTOR SHALL CONTACT THE ONE -CALL UTILITY LOCATE SERVICE 1-800-424-5555 PRIOR TO AND
DURING CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE THE PROJECT ENGINEER AND THE UTILITY
COMPANIES WHEN CONFLICTS OCCUR.
E.) THE CONTRACTOR SHALL CONTACT THE SEATTLE WATER DEPT. PRIOR TO CROSSING THE EXISTING CEDAR RIVER
PIPELINES NOS 1,2, & 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIREMETS ESTABLISHED BY THE
SEATTLE WATER DEPT. FOR THESE CROSSINGS.
TEMPORARY STREET RESTORATION NOTES
A,) THE CONTRACTOR SHALL PATCH ALL TRENCH CUTS AT THE END OF EACH W❑RKING DAY WITH A
TEMPORARY ASPHALT PATCH, EXCEPT THE LAST SECTI❑N OF THE TRENCH WHICH CAN BE COVERED
WITH STEEL SHEETS. THESE PATCHES SHALL BE COMPACTED WITH A ROLLER COMPACTOR TO A DENSITY
WHICH WILL PR❑VIDE A SMOOTH, FIRM SURFACE FOR VEHICLES. THE PATCHES SHALL BE MAINTAINED
DAILY THROUGHOUT THE DURATI❑N OF THE PROJECT TO PREVENT POT H❑LING AND RUTS FROM F❑RMING.
ALL POTHOLES, RUTS, AND BUMPS MUST BE REPAIRED IF THE DEFECT EXCEEDS AN INCH IN DEPTH OR
HEIGHT,
B,) AT THE END OF EACH W❑RKING WEEK, THE ENGINEER WILL INSPECT THE TEMPORARY PATCHES. IF
THE TEMPORARY PATCHES D❑ NOT PR❑VIDE AN ADEQUATE DRIVING SURFACE, AS DETERMINED BY THE
ENGINEER, THE CONTRACTOR SHALL INSTALL THE PERMANENT PATCH AS NOTED ON THE DETAIL SHEET,
wrrq -1,�-j/joj
ASPHALT CONCRETE PATCH
MATCH EXISTING
(APPROX. 5" TO 8"
MIN.)
SHALL
SAW CUT
AND NSAWU STRAIIGHTBLINES ASAL
CEMENT
DIRECTED BY THE ENGINEER
REMOVE LOOSENED
TRIM
CONCRETE
EXISTING CONCRETE
ASPHALT
VERTICALLY
PAVEMENT
3/4"DIA. X 12" LONG DOWEL
EPDXY COATED DOWEL BARS
BAR ©18" ON CENTER
6"
MIN. ON ALL FOUR SIDES
EXISTING RIGID BASE
MIN.
.
12- MIN
12"
COMPACTED TRENCH
BACKFILL
COMPACTED
CRUSHED SURFACING
AS DIRECTED BY THE
ENGINEER
TOP
COURSE.
ASPHALT CONCRETE PAVEMENT OVER CEMENT CONCRETE BASE
RESTORATION DETAIL. 2
MORRIS AVE S AND INTERSECT ONS
N TS
12" PIPE
Q o Q N
C) SHACKLE RODS
(AS REQUIRED)
s
##4 REBAR 8" O.C. E.W.
CENTER IN CONCRETE
PLACE CONCRETE
AGAINST UNDISTURBED
EARTH BOTH FACES
1 a{; M I N
CLASS 5 1/2 SACK
CONCRETE
3000 PSI MIN
N
6 -
3/4" SHACKLE RODS
PLAN
VIEW—
FOR
12" PIPE
a
TYPICAL CONCRETE DEADMAN ANCHOR
DETAIL
RECOMMENDED FOR APPROVAL
WATER UTILITY DATE
WATER MAINTENANCE MANAGER DATE I
PAY LIMIT SEE DETAIL ##1 AND ##2
TRENCH BACKFILL FOR STREET RESTORATION REQUIREMENTS
3'-0" MAINLINE
2'-0" WATI ER SERVICES & HYD7 LATERALS
i
SUBSEQUENT BACKFILL MATERIAL
(NATIVE IF APPROVED BY ENGINEER)
OR IMPORT PER SECTION 9-03.14(1)
GRAVEL BORROW
PROPOSED WATER MAIN WITH POLYWRAP
1'-0" PIPE ZONE MATERIAL PER SECTION 9-03.12(3)
on GRAVEL BACKFILL FOR PIPE ZONE BEDDING
EXCAVATION AND BACKFILL OF
UNSUITABLE FOUNDATION MATERIAL (IF NECESSARY)
_ DEPTH AS APPROVED BY ENGINEER
DEPTH AS REQ'D '_ N MATERIAL SHALL MEET SECTION
- 9-03.9(1) BALLAST
WATER MAIN/ WATER SERVICES
TYPICAL TRENCH BEDDING BACKFILL
*218118
AS -BUILT
DECEMBER 1998
SHEET 6 OF 10
WI-121118111016