Loading...
HomeMy WebLinkAboutWTR2702181.4L) cc 0 N 0 ()o 00 0) 0 0 0 41v B.M. #619-3113 SET CHISELED N. W. > 1.3 T eW STA. 21+2�A 2.6' RT m N COR. OF TRAF. SIG. BOX 0 ELEV.=33.44 < 20+83.4, 20.3 �,j Qw 1 r - - - CONNECT TO ISTING 12" WATER LINE 'q'x69'TEE ( JxFL)1W ONC. BLOCK SEE CONNE&I N DETAILS NO. 5 SMEET-8 Of I-_ TEST STATION I �TORY z , GATE VA VE (FLx, 12 x12" CRl (FLxFL) N4 LLJ TYPE FF O�FICE 1 STORY 211 I HYDRA T ASSEMB Y 1 IT) VALVES (FLxFL) HOUSE > + CD U) SLEEVES (MJ) L0 #205 S.S.+H. U 1 STORY < p C.B. RIM=33.79 RIM=M.76 CN C) OFFICE -i I.E.-33.0 1. E. 7 #419 o Lj__j SALVATION z ARMY C.B. RIM-33.08 ±2,36 L.F. ff 4) m LE.�32.0 0) C.B. RIM=32.71 0 1 #422 PIPE JOINT-_i§O1NG LIMITS 1. E. 30.2 T TA TION < ci-) y F NSTALL LVANI ES 2' 7 +47 F I ENG, 6, 0 25+ 8 �5 0 G 2" IP s 0 GT- 014 TIN(�) ch� 0 -r-62 LIJ c G __ 7T v 0 EM Y VAULT 0 .5 LT I-_ 11­ As G G - G < itl - - 0 C) ±344 L.F.-12 1. ER LINE V) V) V) OSD (/-) ru IP GA c 4. G 0 ro 41, c:) c c -0 --------------- 4- 0 11 0 j C -1 -4 S 01 *18'34" W 0-- ss SAN. 1113 1� G) IN -E- w 8" U) SAN. ss SD U) SD y SS (71 cf) SD s Q I ATN + _T SD Ir SD CD So Ld 0- 0 C/-) W o Of IN Q L.F. 12"' . WA TER LINE UGT UGP u G-CJI UGT UG GT UGP C-) p 4p ��14 p IN IN T G T T U 1p p UGP P UG Ucp WGT - p "j 0-0 oij CROSS V) ARAGE C. R. P. X X SEE DETAILS IN 0 STA. 21+68.5, 71T S.D. M.H. C.B. RIM=3273 STA. 24+22, 14 IYPE F1 8 .9 RIM=33.18 c/) IN L INSULATED FLEXIBLE 0 22'RT (FH)j, .3.5"RT I.E. 8" OIL R > - Q - (WV).E.=31.2 0 X SDSTA. 24+22, 71T Ll R DETAIL ON SHEET 8 rri =29.9 q- f > 12"x6 TEE �(yJxFL)IW CONIC. BLOCK C.B. RIM=33.54 '-RIM=33.19 2 - q 90" BEND (MJxMJ)1W CONIC. BLOCKS N4 12"' +65.4 , 1' RT I.E. 10" E./W.�2.N 6" GATE VALVt14FLxMJ) 1. F. 32.8 19� -12" D.I. PIPE > I.E. 6" N.=30. ±21 L. F. C.B. RIM-=32.70 rn rrl > I H WFllill!�):l HYDRANT ASSEMBLY (23'RT) 1. E. 6 S, 3 0.2 S.D. M. H. S.S. M.H. i.E.=31.0 11%4 RIM=33.14 RIM=33.47 ­11 1 1 Lij 0)0 REMOVE EXISTING HYDRANT ASSEMBLY "(z I.E. 6" N.E.=30.7 OI.E.-30.2 S. S. M. H. E 1. E. 6" N.W.=30.9 RIM=33.21 �RY (J" cn S, D. M. H. 2 AND SALVAGE TO CITY SHPF� 1. E. 6" S.=311 I.E.=29.8 o RIM=33.4 MOVIE THEATRE 6 E I.E. 6" W.=31.3 m E #504 23+62.2 WMH (TEST) N I.E. 6" S.=31.0 REMOVED EXIST. 12x8 TEE c: I.E.=30,95 (�� 4' RT AND 2-8"' G.V. CAP EXIST. 8"W C-:: 22+91 D. 21+26.4, 2.6 RT SEE LL--OUIS 0 20+80, 1 71T 1 2 .7 RT SH 2 INSTALL INSULATED FLEXIBLE I I i *� � 1 0 8 x8" TEE (A,4JxFL) WICONC. BLOCK COUPLING PER DETAIL ON SHEET 8 HO WA R'ys� 8" GATE VALVE (FLxMJ) 2" RT 23+22.70 8" PLUG (MJ) WICONC. BLOCK STA 23+18, 21.8 RT (FH) 0 12"x6" TAPPING TEE V) z ±14 L.F.-8" D.I. WATER LINE 3.0 RT (WV) N �o 6 " G. V. (FLxMJ) 23169 HYDRANT ASSEMBLY (23$ RT) G/ ST STA. 20+78, 7'RT SSA ON L 0 20 40 Lo 6mmmod CONNECT TO EXISTING 8" WATER LINE LLJ [EXPIRES 8/21/99 z _0 gKo 1 20' AFTER ALL REQUIRED TESTING z W a: z 0 Q 0 z 8'-9-90- BEND (MJ)1W CONC. BLOCK 8" SLEEVE (Mi) REMOVE EXISTING HYDRANT ASSEMBLY AND SALVAGE TO CITY SHOPS > JOINT BONDING & GALVANIC ±236 L.F ANODES U-) Lu __j 00 + uj + 1 to Lu 0 L� + >� C'4 cq Nt + >, + + + OC, q -------------------------------- Lo (N clq lc:c EXISTING GROUND AT CIL W) Ci OF ROADWAY clq (n CN Z V) - -------------------------- ----------------------------- N -------------------------------------- ft ----- ---- z ----------------------------------------------------------------------------------------------------- (o Uri U) (o - CN U) CN fy A GALV. < ------------ ------------------------------------------------------------------------------------ ------------------------------------- 1.4 ......... 1.6'.2 ...... . 1-.9 ------------------------- ------------------------------------------------------------------------------- A - - - - - TEIIE-EEC T ----------------- LLJ 3-2 - 4 8 "SD 4.3 3 0 6" CLAY 3.5 < - 1-12" PVC - 4' MIN. -COVER (TYP.) + Lu 1$ss ECT 12 WA _ER 0 VER $ 6 TELIELECT 4 8 "SD 15 "SD DEFL' x TELIELECT- 0 4.2 O - : :CRPLJS ------ ...... ......................... 8 SD -TER - (H YDRA N T) -------- -------- ------------------------8 - ------------ ---------- ................. 00 .................................. ................................. J.: - 4 C 4. or ------------- ----------------- ------- --- - ------- ------- 1-6'!WA ---- -30 V) -10 "SD Z 6 .F.O................ . ..................... ----------AMBOAR& 12"WATER ---------- ------ --------------- ...........................---------------------------------------------------................... 28 CONNECT -TO EXIST. - 12" WATER - �, _ - 0 : 51-112" WATER Iqss 8 SLEEVE INSULATING- CRPL#2 z ....................................................... I 5TA 24+65-.4 NEW 12"'xl2" TEE & VALVE- ----------------------------------------------------------------------------------------------- --- -------------------------------------------------------- -------------------------------------------------------------------- 0 ----------- in 2 6 CONNECT TO EXIST. 8" WA TER AND 5T "SrA TION + z 60"-WATER --------------------------------------------------- _Z;_� --------------------------------------------------------------------------------------------- ---------------------------- - --------------------------------------------------------------------------------------------------------------------------- z CRPL 24 0 m Ld --------- --------- --------- --------- --------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- -22 - )-m-EET --- 4 ---- OF --- TO --- I ----------------------- AS -BUILT ----- 21+00 2J+00 23100 24L0 < 25L0 DECEM'BER 1998 26L0 z z I 2 1 e 10 4 16 r- , Jv SCANNED FEB 1 5 2002