ELECTRICAL SYMBOLS
W
N
J
QLJ
O
s
Z
o
W
CLAMPED FENCE CONNECTION
Z
��o
m w
W
G)
GROUND ROD
QN
g
m �
—G
GROUND WIRE WITH EXOTHERMIC WELD CONNECTION
�u
2 �^
m
O
G
GROUND WIRE (SIZE AS NOTED)
o"N
gym,
z w
w
SWITCHBOARD OR DISTRIBUTION PANELBOARD, 277/480V
U
CD®
m
o
POWER PANEL, 120/208V
o
SPECIAL PANEL OR ENCLOSURE AS NOTED
� cn
Q
1/4 HP
MOTOR 120V (SIZE AS NOTED) 1 PHASE
Z
w
U
L Z
CD
U
O,g HP
MOTOR 480V OR HIGHER (SIZE AS NOTED) 3 PHASE
a
N
—
L
z
W
—
ry
W
a
J
O
U
®MCP
MOTOR. STARTER, MAGNETIC WITH MOTOR CIRCUIT PROTECTOR
a
M
LLJ
W
EMc
ENERGY MANAGEMENT CONTROL SYSTEM PANEL
U
Ep
MOTOR STARTER, MAGNETIC WITH FUSED DISCONNECT SWITCH,
30/20
SWITCH RATING=3OA/20A=FUSE SIZE
U
Q
°
EP
DISCONNECT SWITCH (UNFUSED) SWITCH RATING 30A
a-
�
w
O
L
30
DISCONNECT SWITCH (FUSED) SWITCH RATING 30A/30A FUSE
17�O
Q
30/30
RATI N G
N
JUNCTION BOX, SPECIAL (SIZE NOTED, "WP"=WEATHERPROOF)
\a
PB
PULL BOX (SIZE NOTED, "WP"=WEATHERPROOF)
0
PHOTO -ELECTRIC CONTROLLER
a
m
$FL
FLOAT SWITCH
" E
o'N
RESISTOR
RELAY COIL
O
THERMOSTAT
oQq
s�
SOLENOID VALVE
J
OF
Q
Q
a
PUSH BUTTON STATION (TYPE AS NOTED)
o
O
FEEDER SCHEDULE DESIGNATION (CABLE SCHEDULE DESIGNATOR)
—a—
MEDIUM VOLTAGE CABLE TERMINATION, STRESS CONE
o
zo
FUSE
�
0 V
LLB`
Z
O
TRANSFORMER (CAPACITY, PHASE AND VOLTAGE NOTED)
Q
N
W
(YYYI
TRANSFORMER
POTENTIAL TRANSFORMER WITH PRIMARY FUSE
Q
o_
6
6
w
=
- --
CURRENT TRANSFORMER RATIO AS NOTED
N
O
O
U
`
CIRCUIT BREAKER, HIGH OR MEDIUM VOLTAGE, FIXED
CIRCUIT BREAKER, MEDIUM VOLTAGE DRAW OUT TYPE
a
Q
����
DRAW OUT POWER FUSE
00
�
w
O
Q
o
X
CIRCUIT BREAKER MOLDED CASE, LOW VOLTAGE
Lj
°'
CIRCUIT BREAKER, LOW VOLTAGE DRAW OUT TYPE
— —
CIRCUIT BREAKER WITH SHUNT TRIP DEVICE
c�
o
vs
VOLTMETER SWITCH
0
As
AMMETER SWITCH
0
0
-
rs
TEST SWITCH
z
o
NON -FUSED DISCONNECT SWITCH
oLu
FUSED DISCONNECT SWITCH
0
N
—
GANGED SWITCH, DISCONNECT
N
SWITCH, TOGGLE (MOMENTARY CONTACT)
00
O
0 0 NO
0QNc
SWITCH, PUSH BUTTON, MOMENTARY CONTACT
0
w
z
W
J
GENERAL NOTES:
SWITCH, PUSH BUTTON, DOUBLE CIRCUIT, MOMENTARY CONTACT
0
CEILING MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED)
1. EXISTING UTILITY AND OTHER SUBSURFACE INFORMATION SHOWN ON
° °
THESE PLANS IS NOT GUARANTEED TO BE ACCURATE OR COMPLETE.
(00-�ArS
�
1 LAMP FLUORESCENT LUMINAIRE (TYPE AS NOTED TO SCALE)
THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ANY
AUTOMATIC TRANSFER SWITCH — CIRCUIT BREAKER TYPE
SUBSURFACE OBJECTS THAT MAY CONFLICT WITH ANY CONSTRUCTION.
°1`aNc
SWITCH, PUSH BUTTON, MUSHROOM HEAD, MOMENTARY CONTACT
®
TYPE AS NOTED TO SCALE
2 LAMP FLUORESCENT LUMINAIRE ( )
2. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE
° H
NIGHT LIGHT ON EMERGENCY SYSTEM (TYPE AS NOTED TO
OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS:
_0 - 0 0
HAND —OFF —AUTOMATIC SELECTOR SWITCH
SCALE)
o A
120 220V 277 480V
SWITCH, TEMPERATURE OPERATED NORMALLY OPEN
EXAMPLE OF A CONTINUOUS ROW OF LUMINAIRES.
"A" PHASE (LEFT BUS IN PANEL BLACK BROWN
"B»
PHASE ( CENTER BUS IN PANEL) RED ORANGE
---IH—
CONTACT
LINEAR FLUORESCENT SUSPENDED FROM CEILING (TYPE AS NOTED
"C" PHASE (RIGHT BUS IN PANEL) YELLOW
AND TO SCALE)
BU E
NEUTRAL H
+1::� —OL
CONTACT -OVERLOAD, (MOTOR STARTER)
BATTERYPACK EMERGENCY EGRESS LIGHTS
EQUIPMENT GROUND GREEN GREEN
ISOLATED GROUND GREEN W/
—I o
CONTACT (RELAY SWITCH, MOTOR OPERATED TIMFR, MOTOR
JUNCTION BOX FIELD SIZED
�
YELLOW
STARTER, ETC.) (CR-1 DESIGNATES CONTACT I-U BE WITH
Win,
FLEXIBLE METAL OR LIQUIDTIGHT FLEXIBLE METAL CONDUIT
TRACER
Nc
CONTROL RELAY NO. 1). USE T FOR TIMER, M 1 FOR MOTOR
AS NOTED
STARTER NO. 1, ETC.
3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE
3/4"#10 G
OBSERVED ON ALL MEDIUM VOLTAGE SYSTEMS:
c,R
COIL (RELAY, TIMER, MOTOR STARTER, ETC.)
A%2a,4b,6c
HOME RUN-PANEL/CIRCUIT (IE. A/2a=PANEL A AND
(CR-1 DESIGNATES CONTROL RELAY NO. 1) USE T FOR
CIRCUIT 2a) SLASH MARKS INDICATE QUANTITY OF CONDUCTORS
MEDIUM VOLTAGE
TIMER, M1 FOR MOTOR STARTER NO. 1, D FOR DELAY, ETC.
(SIZE NOTED). LONGER SLASH INDICATES NEUTRAL WIRE (IF REQ'D).
"A" PHASE (LEFT BUS IN PANEL 1 STRIPE OF VIOLET TAPE
REVERSED SLASH INDICATES GROUND WIRE.
"B" PHASE ( CENTER BUS IN PANEL) 2 STRIPES OF VIOLET TAPE
50
A
RELAY/ANSI STANDARD NUMBER FOR FUNCTION
"C" PHASE (RIGHT BUS IN PANEL) 3 STRIPES OF VIOLET TAPE
NOTED LETTER IDENTIFIES SPECIFIC RELAY)
----_---
CONDUIT IN SLAB
4. LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES,
CAPACITOR
X
FIRE SEAL THROUGH THE WALL FOR CONDUITS & CONDUCTORS
ETC. WITH CIRCUIT IDENTIFICATION.
OA
METER (TYPE AS NOTED)
X
FIRE SEAL THROUGH THE WALL FOR WIREWAY & CONDUCTORS
A - AMMETER
KW - KILOWATT METER
CONDUIT TURNING DOWN
KWH - KILOWATT HOUR METER
--------- 0
CONDUIT TURNING UP
PF - POWER FACTOR METER
CONDUIT TERMINATED ABOVE CEILING
V - VOLTMETER
VAR - VAR METER
CONDUIT EXPOSED (RIGID METAL IMC, EMT OR AS NOTED)
FR - FREQUENCY
— —
CONCEALED CONDUIT (UNDERGROUND, UNDER FLOOR, IN WALL OR IN
CEILING)
OK
KEY INTERLOCK
T
TELEPHONE
I
BATTERY
FA
FIRE ALARM CIRCUIT (ADT)
�20A.
DUPLEX RECEPTACLE, 120V, 20. TYPICAL (WP=WEATHER PROOF; GF1=
GROUND CONNECTION
GROUND FAULT INTERRUPTER)
z 3 4
TERMINAL BLOCK (4 TERMINALS)
k�3°
DUPLEX RECEPTACLE, 120V, 15A. CIRCUIT 3a
k�)OED
DEDICATED RECEPTACLE ON DEDICATED CIRCUIT
R)
INDICATOR LIGHT (RED) R=RED, A=AMBER,
(SPECIAL RECEPTACLES TO BE NOTED AS TO MFG. &
G=GREEN, B=BLUE
CATALOG NUMBER)
I—
WIRE CROSSING, NOT SPLICED
020
SINGLE TWISTLOCK RECEPTACLE 120V, 20A
FOURPLEX RECEPTACLE, 120V, 20A
>.�
1
WIRE SPLICED
*20
SINGLE PHASE 208V RECEPTACLE (TYPE AS NOTED)
TR
O
TRANSFORMER RELAY
THREE PHASE RECEPTACLE (T�'PE AS NOTED)
� +*
k�
THREE PHASE RECEPTACLE (TYPE AS NOTED)91,41
#
r
�e
PIGTAIL CONNECTION
DUPLEX RECEPTACLE IN FLOOR
X
EQUIPMENT IDENTIFIER
I
TELEPHONE OUTLET
X _ NAME, Y - HP, KW, OR KVA
y
TELEPHONE OUTLET IN FLOOR
100
IDENTIFIES LUMINAIRE TYPE & WATTAGE (A=TYPE, 100=WATTAGE)
El°
HORN
WALL MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED)
0
MANUAL FIRE ALARM PULL STATION
HI('H INTENSITY DISCHARGE LUMINAIRE (TYPE AND WATTAGE
< s
SMOKE DETECTION HEAD
AS NOTED) _
OH
HEAT DETECTOR -RATE OF RISE
♦�
ROADWAY/FARKING CUTOFF LUMINAIRE (TYPE AND WATTAGE
6
BUZZER
AS NOTED)
COMPUTER WALL OUTLET
®�
EXIT LUMINAIRE, CEILING MOUNTED, DIRECTION OF EGRESS
$
SINGLE POLE TOGGLE. SWITCH
NOTED
�_oI
EXIT LUMINAIRE, WALL MOUNTED, DIRECTION OF EGRESS
$3
THREE—WAY TOGGLE SWITCH
NOTED
■
MAGNETIC DOOR RELEASE
#mmmmmmmmmmmmmmmmmm+
CONDUIT W SEAL FITTING HAZARDOUS AREAS
/ ( )
BY
RECOMMENDED 1
BY
FOR APPROVAL
Mcc
MOTOR CONTROL CENTER
BY
E, j�A ,---�-------��----'r�
RECORD DRAWING INFORMATION COMPILED
FROM CONTRACTOR'S RECORDS. LICENSEE
o ..22024 IS NOT RESPONSIBLE FOR ACCURACY OR
COMPLETENESS OF CONTRACTOR
� � ECORDS.
l\\'j
oNAL t 1
AS
B
EXPIRES:10/05/""' RECORD DRAWING 1
L_
4%= M M M M M = = = = = = = = = = = r
I I I I I I I F_
J�-
SCAtt Nt-D 1SAY 5 1999