HomeMy WebLinkAboutTED4102349.6G4100043. J U Y / ) Q O W L` CD Lc)z ELECTRICAL SYMBOLS W N J QLJ O s Z o W CLAMPED FENCE CONNECTION Z ��o m w W G) GROUND ROD QN g m � —G GROUND WIRE WITH EXOTHERMIC WELD CONNECTION �u 2 �^ m O G GROUND WIRE (SIZE AS NOTED) o"N gym, z w w SWITCHBOARD OR DISTRIBUTION PANELBOARD, 277/480V U CD® m o POWER PANEL, 120/208V o SPECIAL PANEL OR ENCLOSURE AS NOTED � cn Q 1/4 HP MOTOR 120V (SIZE AS NOTED) 1 PHASE Z w U L Z CD U O,g HP MOTOR 480V OR HIGHER (SIZE AS NOTED) 3 PHASE a N — L z W — ry W a J O U ®MCP MOTOR. STARTER, MAGNETIC WITH MOTOR CIRCUIT PROTECTOR a M LLJ W EMc ENERGY MANAGEMENT CONTROL SYSTEM PANEL U Ep MOTOR STARTER, MAGNETIC WITH FUSED DISCONNECT SWITCH, 30/20 SWITCH RATING=3OA/20A=FUSE SIZE U Q ° EP DISCONNECT SWITCH (UNFUSED) SWITCH RATING 30A a- � w O L 30 DISCONNECT SWITCH (FUSED) SWITCH RATING 30A/30A FUSE 17�O Q 30/30 RATI N G N JUNCTION BOX, SPECIAL (SIZE NOTED, "WP"=WEATHERPROOF) \a PB PULL BOX (SIZE NOTED, "WP"=WEATHERPROOF) 0 PHOTO -ELECTRIC CONTROLLER a m $FL FLOAT SWITCH " E o'N RESISTOR RELAY COIL O THERMOSTAT oQq s� SOLENOID VALVE J OF Q Q a PUSH BUTTON STATION (TYPE AS NOTED) o O FEEDER SCHEDULE DESIGNATION (CABLE SCHEDULE DESIGNATOR) —a— MEDIUM VOLTAGE CABLE TERMINATION, STRESS CONE o zo FUSE � 0 V LLB` Z O TRANSFORMER (CAPACITY, PHASE AND VOLTAGE NOTED) Q N W (YYYI TRANSFORMER POTENTIAL TRANSFORMER WITH PRIMARY FUSE Q o_ 6 6 w = - -- CURRENT TRANSFORMER RATIO AS NOTED N O O U ` CIRCUIT BREAKER, HIGH OR MEDIUM VOLTAGE, FIXED CIRCUIT BREAKER, MEDIUM VOLTAGE DRAW OUT TYPE a Q ���� DRAW OUT POWER FUSE 00 � w O Q o X CIRCUIT BREAKER MOLDED CASE, LOW VOLTAGE Lj °' CIRCUIT BREAKER, LOW VOLTAGE DRAW OUT TYPE — — CIRCUIT BREAKER WITH SHUNT TRIP DEVICE c� o vs VOLTMETER SWITCH 0 As AMMETER SWITCH 0 0 - rs TEST SWITCH z o NON -FUSED DISCONNECT SWITCH oLu FUSED DISCONNECT SWITCH 0 N — GANGED SWITCH, DISCONNECT N SWITCH, TOGGLE (MOMENTARY CONTACT) 00 O 0 0 NO 0QNc SWITCH, PUSH BUTTON, MOMENTARY CONTACT 0 w z W J GENERAL NOTES: SWITCH, PUSH BUTTON, DOUBLE CIRCUIT, MOMENTARY CONTACT 0 CEILING MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED) 1. EXISTING UTILITY AND OTHER SUBSURFACE INFORMATION SHOWN ON ° ° THESE PLANS IS NOT GUARANTEED TO BE ACCURATE OR COMPLETE. (00-�ArS � 1 LAMP FLUORESCENT LUMINAIRE (TYPE AS NOTED TO SCALE) THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ANY AUTOMATIC TRANSFER SWITCH — CIRCUIT BREAKER TYPE SUBSURFACE OBJECTS THAT MAY CONFLICT WITH ANY CONSTRUCTION. °1`aNc SWITCH, PUSH BUTTON, MUSHROOM HEAD, MOMENTARY CONTACT ® TYPE AS NOTED TO SCALE 2 LAMP FLUORESCENT LUMINAIRE ( ) 2. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE ° H NIGHT LIGHT ON EMERGENCY SYSTEM (TYPE AS NOTED TO OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: _0 - 0 0 HAND —OFF —AUTOMATIC SELECTOR SWITCH SCALE) o A 120 220V 277 480V SWITCH, TEMPERATURE OPERATED NORMALLY OPEN EXAMPLE OF A CONTINUOUS ROW OF LUMINAIRES. "A" PHASE (LEFT BUS IN PANEL BLACK BROWN "B» PHASE ( CENTER BUS IN PANEL) RED ORANGE ---IH— CONTACT LINEAR FLUORESCENT SUSPENDED FROM CEILING (TYPE AS NOTED "C" PHASE (RIGHT BUS IN PANEL) YELLOW AND TO SCALE) BU E NEUTRAL H +1::� —OL CONTACT -OVERLOAD, (MOTOR STARTER) BATTERYPACK EMERGENCY EGRESS LIGHTS EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GREEN W/ —I o CONTACT (RELAY SWITCH, MOTOR OPERATED TIMFR, MOTOR JUNCTION BOX FIELD SIZED � YELLOW STARTER, ETC.) (CR-1 DESIGNATES CONTACT I-U BE WITH Win, FLEXIBLE METAL OR LIQUIDTIGHT FLEXIBLE METAL CONDUIT TRACER Nc CONTROL RELAY NO. 1). USE T FOR TIMER, M 1 FOR MOTOR AS NOTED STARTER NO. 1, ETC. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE 3/4"#10 G OBSERVED ON ALL MEDIUM VOLTAGE SYSTEMS: c,R COIL (RELAY, TIMER, MOTOR STARTER, ETC.) A%2a,4b,6c HOME RUN-PANEL/CIRCUIT (IE. A/2a=PANEL A AND (CR-1 DESIGNATES CONTROL RELAY NO. 1) USE T FOR CIRCUIT 2a) SLASH MARKS INDICATE QUANTITY OF CONDUCTORS MEDIUM VOLTAGE TIMER, M1 FOR MOTOR STARTER NO. 1, D FOR DELAY, ETC. (SIZE NOTED). LONGER SLASH INDICATES NEUTRAL WIRE (IF REQ'D). "A" PHASE (LEFT BUS IN PANEL 1 STRIPE OF VIOLET TAPE REVERSED SLASH INDICATES GROUND WIRE. "B" PHASE ( CENTER BUS IN PANEL) 2 STRIPES OF VIOLET TAPE 50 A RELAY/ANSI STANDARD NUMBER FOR FUNCTION "C" PHASE (RIGHT BUS IN PANEL) 3 STRIPES OF VIOLET TAPE NOTED LETTER IDENTIFIES SPECIFIC RELAY) ----_--- CONDUIT IN SLAB 4. LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, CAPACITOR X FIRE SEAL THROUGH THE WALL FOR CONDUITS & CONDUCTORS ETC. WITH CIRCUIT IDENTIFICATION. OA METER (TYPE AS NOTED) X FIRE SEAL THROUGH THE WALL FOR WIREWAY & CONDUCTORS A - AMMETER KW - KILOWATT METER CONDUIT TURNING DOWN KWH - KILOWATT HOUR METER --------- 0 CONDUIT TURNING UP PF - POWER FACTOR METER CONDUIT TERMINATED ABOVE CEILING V - VOLTMETER VAR - VAR METER CONDUIT EXPOSED (RIGID METAL IMC, EMT OR AS NOTED) FR - FREQUENCY — — CONCEALED CONDUIT (UNDERGROUND, UNDER FLOOR, IN WALL OR IN CEILING) OK KEY INTERLOCK T TELEPHONE I BATTERY FA FIRE ALARM CIRCUIT (ADT) �20A. DUPLEX RECEPTACLE, 120V, 20. TYPICAL (WP=WEATHER PROOF; GF1= GROUND CONNECTION GROUND FAULT INTERRUPTER) z 3 4 TERMINAL BLOCK (4 TERMINALS) k�3° DUPLEX RECEPTACLE, 120V, 15A. CIRCUIT 3a k�)OED DEDICATED RECEPTACLE ON DEDICATED CIRCUIT R) INDICATOR LIGHT (RED) R=RED, A=AMBER, (SPECIAL RECEPTACLES TO BE NOTED AS TO MFG. & G=GREEN, B=BLUE CATALOG NUMBER) I— WIRE CROSSING, NOT SPLICED 020 SINGLE TWISTLOCK RECEPTACLE 120V, 20A FOURPLEX RECEPTACLE, 120V, 20A >.� 1 WIRE SPLICED *20 SINGLE PHASE 208V RECEPTACLE (TYPE AS NOTED) TR O TRANSFORMER RELAY THREE PHASE RECEPTACLE (T�'PE AS NOTED) � +* k� THREE PHASE RECEPTACLE (TYPE AS NOTED)91,41 # r �e PIGTAIL CONNECTION DUPLEX RECEPTACLE IN FLOOR X EQUIPMENT IDENTIFIER I TELEPHONE OUTLET X _ NAME, Y - HP, KW, OR KVA y TELEPHONE OUTLET IN FLOOR 100 IDENTIFIES LUMINAIRE TYPE & WATTAGE (A=TYPE, 100=WATTAGE) El° HORN WALL MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED) 0 MANUAL FIRE ALARM PULL STATION HI('H INTENSITY DISCHARGE LUMINAIRE (TYPE AND WATTAGE < s SMOKE DETECTION HEAD AS NOTED) _ OH HEAT DETECTOR -RATE OF RISE ♦� ROADWAY/FARKING CUTOFF LUMINAIRE (TYPE AND WATTAGE 6 BUZZER AS NOTED) COMPUTER WALL OUTLET ®� EXIT LUMINAIRE, CEILING MOUNTED, DIRECTION OF EGRESS $ SINGLE POLE TOGGLE. SWITCH NOTED �_oI EXIT LUMINAIRE, WALL MOUNTED, DIRECTION OF EGRESS $3 THREE—WAY TOGGLE SWITCH NOTED ■ MAGNETIC DOOR RELEASE #mmmmmmmmmmmmmmmmmm+ CONDUIT W SEAL FITTING HAZARDOUS AREAS / ( ) BY RECOMMENDED 1 BY FOR APPROVAL Mcc MOTOR CONTROL CENTER BY E, j�A ,---�-------��----'r� RECORD DRAWING INFORMATION COMPILED FROM CONTRACTOR'S RECORDS. LICENSEE o ..22024 IS NOT RESPONSIBLE FOR ACCURACY OR COMPLETENESS OF CONTRACTOR � � ECORDS. l\\'j oNAL t 1 AS B EXPIRES:10/05/""' RECORD DRAWING 1 L_ 4%= M M M M M = = = = = = = = = = = r I I I I I I I F_ J�- SCAtt Nt-D 1SAY 5 1999