HomeMy WebLinkAboutSWP2702711.10GENERAL STRUCTURAL NOTES
T
T GENER
THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE
N STARTING WORK. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCY. USE DETAIL
MARKED "TYPICAL" WHEREVER APPLICABLE. CHANGES, OMISSIONS OR SUBSTITUTIONS ARE
N NOT PERMITTED WITHOUT WRITTEN APPROVAL OF THE ENGINEER. REFER TO THE
SPECIFICATIONS FOR FURTHER REQUIREMENTS. DO NOT SCALE THE DRAWINGS.
ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2003 EDITION OF THE
c/) INTERNATIONAL BUILDING CODE AND WSDOT "STANDARD SPECIFICATIONS."
THE DESIGN, ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS,
ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY
THE ENGINEER OF RECORD. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE
STRUCTURE PRIOR TO THE COMPLETION OF ALL WALLS, TOP SLABS AND FINISH MATERIALS. THE
CONTRACTOR SHALL PROVIDE THE NECESSARY BRACING TO PROVIDE STABILITY PRIOR TO THE APPLICATION
OF THE ABOVE MENTIONED COMPONENTS.
THE GENERAL NOTES APPLY TO ALL STRUCTURES UNLESS NOTED OTHERWISE (U.N.O.). LOCATION
AND SIZE OF ANCHOR BOLTS FOR SPECIFIC EQUIPMENT SHALL BE SPECIFIED BY THE VENDOR.
CONTRACTOR SHALL COORDINATE LOCATIONS OF STRUCTURAL OPENINGS, PENETRATIONS AND
EMBEDDED ITEMS WITH THE CIVIL SECTIONS OF THE DRAWINGS, AND WITH SUPPLIERS AND SUBCONTRACTORS
AS MAY BE REQUIRED.
SPECIAL INSPECTION do TESTING
SPECIAL INSPECTIONS SHALL MEET THE REQUIREMENTS OF IBC CHAPTER 17 AND WSDOT "STANDARD
SPECIFICATIONS".
SPECIAL INSPECTORS SHALL BE UNDER THE SUPERVISION OF A WASHINGTON
REGISTERED CIVIL ENGINEER. OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH APPROVED
DRAWINGS AND SPECIFICATIONS.
FURNISH INSPECTION REPORTS TO THE BUILDING DEPARTMENT AND ENGINEER.
DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
CONTRACTOR FOR CORRECTION; THEN, IF NOT CORRECTED, TO THE BUILDING
DEPARTMENT AND ENGINEER. SUBMIT A FINAL REPORT, SIGNED BY A WASHINGTON
REGISTERED CIVIL ENGINEER, STATING THE WORK WAS IN CONFORMANCE WITH
THE APPROVED DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE
WORKMANSHIP PROVISIONS OF IBC AND WSDOT "STANDARD SPECIFICATIONS."
SPECIAL INSPECTION REQUIRED:
CONCRETE: IN ACCORDANCE WITH SECTION 1704.4 AND TABLE 1704.4 OF IBC AND WSDOT "STANDARD
SPECIFICATIONS".
SOIL: IN ACCORDANCE WITH SECTION 1704.7 OF IBC AND WSDOT "STANDARD SPECIFICATIONS".
SHOP DRAWINGS
SHOP DRAWINGS, WHERE REQUIRED, SHALL BE CHECKED AND APPROVED BY THE GENERAL
CONTRACTOR PRIOR TO SUBMITTING FOR ENGINEER REVIEW. SHOP DRAWINGS SHALL BE
SUBMITTED TO THE ENGINEER FOR REVIEW OF DESIGN INTENT, PRIOR TO FABRICATION.
GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF
DIMENSIONS AND DETAILS FOR EACH SUBCONTRACTOR.
PRECAST/CAST—IN—PLACE INTERIOR DIMENSIONS SHOWN ON THE DRAWINGS ARE NOMINAL AND
SHALL BE ADJUSTED, IF NECESSARY, TO MATCH THE ACTUAL PRECAST BOX CULVERT DIMENSIONS.
DESIGN LOADS
AN EQUIVALENT FLUID PRESSURE — 90 PCF
DESIGN LIVE LOAD — AASHTO H2O-44 LOADING
FOUNDATION DATA:
ALLOWABLE BEARING PRESSURE: ........................................... 2,000 PSF
EXTEND ALL EXTERIOR FOOTINGS 2'-0" MINIMUM BELOW FINISHED GRADE, U.N.O. BOTTOM OF ALL FOOTINGS
TO BEAR ON NATIVE, INORGANIC, UNDISTURBED SOIL OR COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH
THE SOIL REPORT NO. 2006-067-21 FILED BY "HWA GEOSCIENCES, INC.", DATED JANUARY 12, 2007.
NO FOOTING SHALL BEAR HIGHER THAN 1 VERTICAL TO 1.5 HORIZONTAL SLOPE ABOVE ANY EXCAVATION,
EXISTING OR PLANNED. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING TO PREVENT MOVEMENT OF
WALLS IF BACKFILL IS PLACED BEFORE FLOOR SYSTEM IS IN PLACE. THERE SHALL BE 95% COMPACTION
(ASTM D1557 MODIFIED PROCTOR DENSITY) OF ALL BACKFILL SOIL UNDER SLABS ON GRADE.
CONTRACTOR MUST VERIFY EXISTING CONDITIONS PRIOR TO START WORK. CONTRACTOR SHALL BECOME
FAMILIAR WITH THE SOIL CONDITION BY READING SOIL REPORT.
CAST —IN —PLACE CONCRETE
CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES:
28—DAY COMPRESSIVE STRENGTH f'c=4,000 PSI, U.N.O.
AIR ENTRAINMENT: 5%-7%
MAXIMUM SLUMP: 3" FOR SLABS AND FOOTINGS, 4" FOR WALLS AND BEAMS. CONSTRUCTION TO BE IN
ACCORDANCE WITH ACI 318, "PART 2—STANDARD FOR TESTS AND MATERIALS" AND "PART 3 —
CONSTRUCTION REQUIREMENTS AND WSDOT STANDARD SPECIFICATIONS."
SUBMIT MIX DESIGN FOR REVIEW AND PROVIDE NOT LESS THAN 6 SACKS OF CEMENT PER CUBIC YARD FOR
ALL CONCRETE WITH MAXIMUM W/C=0.45.
4(a)o
4axwy I & 08b0rne, Iw.
CONSULTING ENGINEERS
701 DEXTER AVENUE NORTH SUITE 200
SEATTLE, WASHINGTON 98109 (206) 284-0860
REINFORCING STEEL
DEFORMED BARS: ASTM A615, GRADE 60 (GRADE 40 FOR #3).
UNLESS OTHERWISE NOTED ON THESE DRAWINGS, MINIMUM CONCRETE COVER FOR REINFORCING ALTERNATE SEE LAP
BARS SHALL BE AS FOLLOWS: HOOKS SCHEDULE
CONCRETE CAST AGAINST SOIL=3".
FORMED CONCRETE AGAINST SOIL=2".
WALLS AND BEAMS EXPOSED TO WATER & WEATHER=2".
WALLS AND BEAMS DRY CONDITION=1 1 /2". iL ift
PROVIDE 2—#5 MIN. U.N.O. TRIM BARS AROUND ALL OPENINGS IN CONCRETE WALLS OR SLAB al J I
EXTENDING 2'-6" PAST CORNERS, TYP. AT TIME OF CONCRETE PLACEMENT, REINFORCING SHALL j o PROVIDE
BE FREE OF MUD, OIL, OR OTHER NONMETALLIC COATINGS THAT MAY DECREASE BOND. W = VERTICAL
N N CORN
WELDING OF REINFORCING BARS SHALL CONFORM TO ANSI/AWS D1.4. BAR
WHERE PERMITTED, LOW HYDROGEN WELDING RODS SHALL BE USED FOR ALL WELDING OF
REINFORCING BARS. FIELD WELDING OF REINFORCING BARS IS NOT ALLOWED ON THIS JOB.
SUBMIT SHOP DRAWINGS OF REINFORCING STEEL FOR REVIEW BY THE ENGINEER PRIOR TO
FABRICATION. REINFORCING SHALL BE DETAILED IN ACCORDANCE WITH ACI 315 AND 318 (LATEST
EDITION).
21011
REVISION
BY I DATE I APPR
SEE LAP
SCHEDULE
SINGLE CURTAIN
INTERSECTION
CORNER
TYPICAL REINFORCING STEEL
AT WALL INTERSECTION
NOT TO SCALE
REINF.
#4
2'-4"
#5
3'-0"
#6
3'-6"
#7
4'-3"
#8
4'-10"
#9
5'-3"
#10
6'-6"
#11
8'-0"
TYPICAL LAP
SCHEDULE 2
NOT TO SCALE 7,
SUPPLEMENTAL STRUCTURAL ABREVIATION S:
ABV.
ABOVE
FRM'G
FRAMING
STIRR.
STIRRUP
A.F.F.
ABOVE FINISH FLOOR
F.S.
FAR SIDE
STRUC.
STRUCTURE(AL)
ADD'L.
ADDITIONAL
FTG.
FOOTING
SYM.
SYMMETRICAL
ADJ.
ADJACENT
GA.
GAUGE
T.
TOP
AL.
ALUMINUM
G.B.
GRADE BEAM
T&G
TONGUE AND GROOVE
APPRX.
APPROXIMATE
GLB
GLUE —LAMINATED BEAM
TMPRY.
TEMPORARY
ARCH.
ARCHITECTURAL
H.A.S.
HEADER ANCHOR STUDS
T.N.
TOE NAIL
®
AT
HDR.
HEADER
T.O.
TOP OF...
BOT.
BOTTOM
H.F.
HEM —FIR
TRANS.
TRANSVERSE
BEL.
BELOW
HGR.
HANGER
HSS
TUBING STRUCTURAL
B.F.
BRACED FRAME
H.S.B.
HIGH STRENGTH BOLT (A325 U.N.O.)
IBC
INTERNATIONAL BUILDING CODE
BM
BEAM
I.F.
INSIDE FACE
UNLESS NOTED OTHERWISE
B.N.
BOUNDRY NAIL
INT.
INTERIOR
VFY.U.N.O.
BNDRY.
BOUNDRY
JST.
JOIST
W.H.S.VERIFY
W.H.
WELDED HEADED STUD
B.O.
BOTTOM OF...
K
KIPS (1000 POUNDS)
W.P.
WORK POINT
BRDG.
BRIDGE(ING)
LAT.
LATERAL
WS
WESTERN SERIES
BRG.
BEARING
LDGR.
LEDGER
W.T.S.
WELDED THREADED STUD
CAM.
CAMBERED)
LLH
LONG LEG HORIZONTAL
X—STG
EXTRA STRONG
CANT.
CANTILEVERED)
LLV
LONG LEG VERTICAL
XX—STG
DOUBLE EXTRA STRONG
C.D.F.
CONTROLLED DENSITY FILL
L.S.
LAG SCREW
C.G.
CENTER OF GRAVITY
LSL
LAMINATED STRAND LUMBER
C.I.P.
CAST IN PLACE
LT. WT.
LIGHT WEIGHT
C.J.
CONSTRUCTION JOINT
LVL
LAMINATED VENEER LUMBER
COL.
COLUMN
MAS.
MASONRY
CONST.
CONSTRUCTION
MAT'L
MATERIAL
CONT.
CONTINUOUS
M.B.
MACHINE BOLT (A307)
CTSK.
COUNTERSINK
MFR.
MANUFACTURER
DBL.
DOUBLE
MRF.
MOMENT RESISTING FRAME
D
DEPTH
MTL.
METAL
d
PENNY (NAILS)
(N)
NEW MEMBER
D.F.
DOUGLAS FIR
N.S.
NEAR SIDE
DIAG.
DIAGONAL
O.H.
OVERHANG
DIAPH.
DIAPHRAGM
ORNT.
ORIENTATE (ION)
do
DITTO (DO OVER)
PAR.
PARALLEL
DWG.
DRAWING
P/C
PRECAST CONCRETE
DWL.
DOWEL
PERP.
PERPENDICULAR
EA.
EACH
PSL
PARALLEL STRAND LUMBER
(E)
E.F.
EXISTING MEMBER
EACH FACE
P.T.
P/T
PRESSURE TREATED)
POSTTENSIONED
E.J.
EXPANSION JOINT
QTY.
Q
UANITY
QD-271
EMBD.
EMBEDMENT)
REF.
REFERENCE
E.N.
EDGE NAIL
REINF.
REINFORCEMENT
ENG.
ENGINEER
SHT.
SHEET
EQ.
EQUAL
SHTG.
SHEATHING
E.S.
EACH SIDE
SIM.
SIMILAR
EXT.
EXTERIOR
SKW.
SKEWED)
F.F.E.
FINISHED FLOOR ELEVATION
SPC.
SPACING
F.N.
FACE NAIL
S.S.
STAINLESS STEEL
FND.
FOUNDATION
STGR.
STAGGER
F.O.
FACE OF...
STIFF.
STIFFENER
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORI)MKYY
VERTICAL- NAVD 19M
HORIZONTAL- MAD 1983/1991
DATU M
CITY OF
RENTON
Planning/Building/Public Works Dept.
RECOMMENDED FOR APPROVAL
BY --—— ---- Date:
BY / ------------- Date: --------
BY ---------------- Date: --------
BY --------------- Date:--------
1-121711111110
RENTON VILLAGE STORM SYSTEM PROJECT
PAGE:
GENERAL STRUCTURAL NOTES
AND TYPICAL STRUCTURAL DETAILS
SHEET: 10 OF. 12