HomeMy WebLinkAboutSWP2702750.341 C(D)800 C8100177.DWG
ca
c
L
0
a
U
0
a
co
rn
00
N
J
U
ti
0
0
a
W
x
0
0
0
0
00
U
0
0
0
N
N
0
0
0
w
Li
J
O
00
�o
00 0 Z
o =N—i
JLi )
U
�w
ry O
Q
�In
__j_
w
Li
Q
w
(DS
�0)oo
� W
L
0
r � 04
W
�
�v�wz
o�C'4
QZo
Qw
zw
co
Q
z�
O
IL
O
��
ZWU
z W
O Q
L
m1,
J
�
�>
C/-)
U
C) 0
a� E
o�
0
70
a
V
W
�w
a
L
�0
�E
�E
�E
O'N
�I C
0
a-
>z
W U Z
�Zo
O
Z
N Z O
J O U
W
Q
U
L_
C)
Q
m
=
yolk
}
oY
=
J
Y
o�
W
o
N
nU
0
0
=
U
as
V
Q
o
o
w
�
Q
0
0
m
J
0
Z
3
Q
0
0
0
W
Of
7-
0
W
SUBGRADE ELEVATION.
FOR MATERIALS OVER
SUBGRADE SEE DRAWING
1 C(G)800.
BACKFILL MATERIAL
PER SPECIFICATION
02225
ACTUAL SIDE SLOPE
BY CONTRACTOR
_:d
w
WARNING TAPE
>
BEDDING MATERIAL
FOR RIGID PIPE OR
BEDDING MATERIAL
y//?/ FOR THERMOPLASTIC
PIPE
4 MIN
WORK BEDDING UNDER
Q�� %i% PIPE HAUNCHES FOR
FLEXIBLE PIPE
12" CRUSHED SURFACING
BASE COURSE
SUBGRAD UNDISTURBED PIPE DIAMETER SEE TRENCH NOTE 5
6" MIN 6" MIN
TRENCH MAX WIDTH
36" (WHEN D<=15") OR
1.5D+ 18" (WHEN D=> 18")
SECTION STORM DRAINAGE TRENCH
SCALE: NONE
MATCH EXISTING
GRADE AT LIMITS
OF CLEAR AND
GRUB ---\
EXISTING
GROUND
LINE
TRENCH SUBGRADE
SEE TRENCH NOTE 4
1C(D)800
STORM DRAINAGE TRENCH NOTES
1. THE TRENCH WIDTH AT THE TOP SHALL BE DETERMINED 3. TRENCH SUPPORT SYSTEM SHALL BE USED WHERE
BY THE CONTRACTOR TO SUIT HIS CONSTRUCTION REQUIRED BY W.I.S.H.A. PER CHAPTER 296-155 WAC.
OPERATIONS. TRAFFIC FLOW AND PROTECTION OF
ADJACENT PROPERTY ARE THE CONTRACTOR'S 4. TRENCH SUBGRADE SHALL BE APPROVED BY OWNER'S
RESPONSIBILITY. REPRESENTATIVE PRIOR TO PLACING FILL MATERIALS.
UNAPPROVED SUBGRADES SHALL BE CORRECTED IN
2. THE HEIGHT AND THE SUPPORT OF THE VERTICAL ACCORDANCE WITH SPECIFICATION 02225.
SECTION SHALL BE DETERMINED BY THE CONTRACTOR
AS REQUIRED FOR THE PROTECTION OF ADJACENT 5. OWNER'S REPESENTATIVE SHALL DETERMINE IF 12"
PROPERTIES AND IMPROVEMENTS. CRUSHED SURFACING BASE COURSE IS REQUIRED.
3' 6"
LIMIT OF 12" DEPTH CLEAR AND GRUB
AREA PER DEMOLITION PLAN
FINISHED GROUND
LINE 3' MIN FILL WITH S1 , UNLESS
FABRIC OTHERWINOTED ON
n111- e1"7)A flIK I(1 7)1 AKIC`
PERFORATED STORM DRAIN,
SIZE, AND IE PER PLAN.
PROVIDE AT LEAST OF 6"
GRAVEL BACKFILL FOR
DRAINS OVER TOP OF
PIPE AND FABRIC.
NOTE:
PLACE ADDITIONAL GRAVEL
BACKFILL FOR DRAINS AS
AS REQUIRED TO LIMIT
THIS DIMENSION TO 3 FEET.
SECTION PERFORATED DRAIN TRENCH
SCALE. NONE
2' MIN
FABRIC OVERLAP
FINISH z_
ED GRADE
11 11111� 111 111-III=I11=� TRAIL MAINT
-1TI—III—III III I I—III=i
=� 11-III, III=111—III—III- Q0 ACCESS
.III-
PERFORATED STORM DRAIN,
SIZE, AND IE PER PLAN. PROVIDE AT LEAST 6" GRAVEL PLACE GEOTEXTILE FABRIC PER
__
BACKFILL FOR DRAINS OVER — — 02722 AND COVER WITH GRAVEL
TOP OF PIPE AND FABRIC _ p BACKFILL FOR DRAINS. WRAP FABRIC
OVER TOP OF PIPE WITH 2' MIN
uj
OVERLAP. COVER UPPER LAYER
o- / OF FABRIC WITH 6" MIN GRAVEL
—�" -- —` BACKFILL FOR DRAINS.
SECTION PERFORATED DRAIN TRENCH C
SCALE: NONE ALONG TRAIL/MAINT ACCESS 1 C(D 22 1 C(D)800
1 C(D)23
0 1CD27
o^0 1 C(D)28
1 C(D)32
1CD37
� o
0
EXTEND INTO 00
UNDISTURBED
SOIL (TYP) z
LOCATION
PER PLAN N 24" SD (TYP)
- T - - - - - - - - - - - - - - - - -
FOLLOWING 12" CLEAR AND GRUB,
PLACE GEOTEXTILE FABRIC (PER
02722) AND COVER WITH GRAVEL
BACKFILL FOR DRAINS. WRAP FABRIC
OVER TOP OF PIPE WITH 3' MIN
OVERLAP. COVER UPPER LAYER OF
FABRIC WITH 6" MIN GRAVEL
BACKFILL FOR DRAINS.
1C(D 22
1 C(D)23 1 C(D)37
1 C(D)27 1 C(D)38
1 C(D)28 1 C(D)39
1 C(D)30 1 C(D)40
1 C(D)32 1 C(D)44
1 C(D)34 1 C(D)45
1 C(D)35
CDF TRENCH
DAM
2' MIN
(TYP)
-------------� r�-------------
2' MIN _ \---CDF TRENCH DAM
LIMITS OF CENTERED IN
TRENCH I PIPE SECTION
DETAIL TRENCH DAM
SCALE: NONE 1 C(D)27 1 C(D)800
LIMITS OF UNDISTURBED
SECTION
SCALE: NONE
TRENCH BACKFILL PER
02225 AS REQUIRED
TRENCH DAM
1 C(D
r1 r\ / 1 (1 n
1' MIN
GENERAL STORM DRAINAGE NOTES:
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE —CONSTRUCTION
MEETING MUST BE HELD WITH THE CITY OF RENTON DEVELOPMENT SERVICES DIVISION,
PLAN REVIEW PROJECT MANAGER.
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE "1998" EDITION OF THE "STANDARD
SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION" PREPARED BY W.S.D.O.T.,
AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY
OF RENTON.
3. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED
PLANS WHICH ARE ON FILE WITH THE CITY OF RENTON. ANY DEVIATION FROM
THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON
DEVELOPMENT SERVICES DIVISION.
4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION
IS IN PROGRESS.
5. CONSTRUCTION NOISE SHALL BE LIMITED AS PER KING COUNTY CODE (SECTION 12.88);
FOR THIS PROJECT THIS IS 6 A.M. TO 11 P.M. WEEKDAYS AND 6 A.M. TO 11 P.M.
ON WEEKENDS.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY
DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT
THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION
WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE
TRAVELED RIGHT—OF—WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AT
LEAST ONE FLAGGER FOR EACH LANE OF TRAFFIC AFFECTED. ALL SECTIONS OF THE
1998 WSDOT STANDARD SPECIFICATIONS 1—07.23, SHALL APPLY.
7. FOR DATUM INFORMATION, REFER TO DRAWING 04.
8. ALL SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING
AND GRADING, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL
CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON —SITE EROSION HAS PASSED.
9. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR
TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY
THE DEVELOPMENT SERVICES DIVISION.
10. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION.
THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE
FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING
MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. ALL TRENCH BACKFILL SHALL BE
COMPACTED TO MINIMUM 85% FOR LANDSCAPED AREAS AND 95% FOR PAVEMENT AND
STRUCTURAL FILL AREAS PER ASTM D-1 557-70. WHERE A PIPE CLEARS AN EXISTING OR NEW
UTILITY BY 6" OR LESS, BLOCKING SHALL BE PLACED AS CUSHION BETWEEN UTILITIES.
11. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES
SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE.
12. THE FOLLOWING APPURTENANCE DESIGNATIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH
THE APPROPRIATE CITY OF RENTON STANDARD PLAN: CB TYPE 1 — STD PLAN B012,
CB TYPE 2 — STD PLANS B027 AND B027.1 (MODIFIED AS INDICATED ON DRAWING 1 C(D)801 ,
MH TYPE 3 — STD PLAN B028.
13. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES
NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED
WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT
ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM
PROVIDED DURING CONSTRUCTION.
14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFTEY
DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT
THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION
WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE
TRAVELED RIGHT—OF—WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AN
APPROVED TRAFFIC CONTROL PLAN BY THE TRANSPORTATION DIVISION. ALL SECTIONS OF THE
W.S.D.O.T. STANDARD SPECIFICATIONS 1 —10.2, TRAFFIC CONTROL MANAGEMENT, SHALL APPLY.
15. ALL CATCH BASINS SHALL HAVE LOCKING GRATES, AND ALL DRAINAGE MANHOLES SHALL
HAVE SOLID LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT
RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS.
16. IDENTIFYING COORDINATES SHALL BE THE CENTER OF THE GRATE FOR CATCH BASINS AND
CENTER OF STRUCTURE FOR MANHOLES.
1 C(D)800 I RECOMMENDED BY
i FOR APPROVAL BY
BY I
am m m m m m m m m m m m m m m m m r
N
RECORD DRAWING INFORMATION COMPILED �o� ,pF3222s 2
FROM CONTRACTOR'S RECORDS. LICENSEE �SSIpNAL��
IS NOT RESPONSIBLE FOR ACCURACY OR
COMPLETENESS OF CONTRACTOR'S RECORDS.
EXPIRES: 06/05/'02
RECORD DRAWING,
r m m m m m m m m m m m m m m== r
1443 1. 0 - -" 7-s`10 *,' SCANNED OCT 4 2000