Loading...
HomeMy WebLinkAboutSWP2702750.50 U W of Z 0 zz 0 x x 0 0 0 0 0 0 N N N 0 0 LA - 0 z W J �O U LLJ n LW O Z w w W —z 'oo >0)000 LL W a a N O LLJ V L u � v� 0�J < (Do > o O C Q Q� CD z � OIL < U OzW � Z — U U LJ Q W L m � L W a D �> cn U Qo 0 o� ).0 O p o �< a U � w �w �a_ a- E�---1 �c �a �E _Q) �E �,. ;_ c N C(DD o � a. C� >z > W U i Z �zo 0 _ ,90 U U O O 2 ,l^1 a 0 U U Q _ � o� _I U oY J U Y o c Y = Y � D 0 WU O y< O W U ad Q 0 o w � � o 0 z m z 0 w G✓ o ELECTRICAL SYMBOLS - E-- CLAMPED FENCE CONNECTION O GROUND ROD - G - GROUND WIRE WITH EXOTHERMIC WELD CONNECTION G GROUND WIRE (SIZE AS NOTED) ® SWITCHBOARD OR DISTRIBUTION PANELBOARD, 277/480V o POWER PANEL, 120/208V o SPECIAL PANEL OR ENCLOSURE AS NOTED 0/41HP MOTOR 120V (SIZE AS NOTED) 1 PHASE $15 HP MOTOR 480V OR HIGHER (SIZE AS NOTED) 3 PHASE ® McP MOTOR STARTER, MAGNETIC WITH MOTOR CIRCUIT PROTECTOR ENERGY MANAGEMENT CONTROL SYSTEM PANEL MOTOR STARTER, MAGNETIC WITH FUSED DISCONNECT SWITCH, 30/20 SWITCH RATING=30A/20A=FUSE SIZE E DISCONNECT SWITCH (UNFUSED) SWITCH RATING 30A o [Ell DISCONNECT SWITCH (FUSED) SWITCH RATING 30A/30A FUSE 30/30 RATI N G iB I JUNCTION BOX, SPECIAL (SIZE NOTED, "WP"=WEATHERPROOF) © PULL BOX (SIZE NOTED, "WP"=WEATHERPROOF) PE PHOTO -ELECTRIC CONTROLLER $FL FLOAT SWITCH -N"- RESISTOR RELAY COIL O THERMOSTAT & SOLENOID VALVE PUSH BUTTON STATION (TYPE AS NOTED) O FEEDER SCHEDULE DESIGNATION (CABLE SCHEDULE DESIGNATOR) -a- MEDIUM VOLTAGE CABLE TERMINATION, STRESS CONE --®- FUSE ❑T TRANSFORMER (CAPACITY, PHASE AND VOLTAGE NOTED) TRANSFORMER POTENTIAL TRANSFORMER WITH PRIMARY FUSE - CURRENT TRANSFORMER RATIO AS NOTED �- CIRCUIT BREAKER, MEDIUM VOLTAGE, FIXED CIRCUIT BREAKER, MEDIUM VOLTAGE DRAW OUT TYPE EQUIPMENT (AIR CIRCUIT BREAKER) DRAW OUT POWER FUSE - CIRCUIT BREAKER MOLDED CASE, LOW VOLTAGE CIRCUIT BREAKER, LOW VOLTAGE DRAW OUT TYPE sr — CIRCUIT BREAKER WITH SHUNT TRIP DEVICE = VOLTMETER SWITCH As AMMETER SWITCH -,- TEST SWITCH NON -FUSED DISCONNECT SWITCH -o FUSED DISCONNECT SWITCH GANGED SWITCH, DISCONNECT -✓� SWITCH, TOGGLE (MOMENTARY CONTACT) o NO 0 I °Nc SWITCH, PUSH BUTTON, MOMENTARY CONTACT 1 0003O. UWC GENERAL NOTES: IL-n SWITCH, PUSH BUTTON, DOUBLE CIRCUIT, MOMENTARY CONTACT 0 CEILING MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED) 1. EXISTING UTILITY AND OTHER SUBSURFACE INFORMATION SHOWN ON ° ° THESE PLANS IS NOT GUARANTEED TO BE ACCURATE OR COMPLETE. (0.-�ArS � 1 LAMP FLUORESCENT LUMINAIRE (TYPE AS NOTED TO SCALE) THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ANY AUTOMATIC TRANSFER SWITCH - CIRCUIT BREAKER TYPE SUBSURFACE OBJECTS THAT MAY CONFLICT WITH ANY CONSTRUCTION. °-'L°NC SWITCH, PUSH BUTTON, MUSHROOM HEAD, MOMENTARY CONTACT ® 2 LAMP FLUORESCENT LUMINAIRE (TYPE AS NOTED TO SCALE) 2. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE ° H NIGHT LIGHT ON EMERGENCY SYSTEM (TYPE AS NOTED TO OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: -°-° 0 A HAND -OFF -AUTOMATIC SELECTOR SWITCH SCALE) 0 120 220V 277 480V -°�°- SWITCH, TEMPERATURE OPERATED NORMALLY OPEN EXAMPLE OF A CONTINUOUS ROW OF LUMINAIRES. "A" PHASE (LEFT BUS IN PANEL BLACK BROWN —i I— CONTACT LINEAR FLUORESCENT SUSPENDED FROM CEILING ( TYPE AS NOTED „B„ PHASE ( CENTER BUS IN PANEL) RED ORANGE C PHASE (RIGHT BUS IN PANEL) BLUE YELLOW AND TO SCALE) NEUTRAL WHITE GRAY -44:�- -OL CONTACT -OVERLOAD, (MOTOR STARTER) BATTERYPACK EMERGENCY EGRESS LIGHTS EQUIPMENT GROUND GREEN GREEN O ISOLATED GROUND GREEN W/ --� o CONTACT (RELAY SWITCH, MOTOR OPERATED TIMER, MOTOR JUNCTION BOX, FIELD SIZED YELLOW STARTER, ETC.) (CR-1 DESIGNATES CONTACT TO BE WITH FLEXIBLE METAL OR LIQUIDTIGHT FLEXIBLE METAL CONDUIT TRACER - CONTROL RELAY NO. 1). USE T FOR TIMER, M 1 FOR MOTOR AS NOTED STARTER NO. 1, ETC. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE 3/4"# 10 G OBSERVED ON ALL MEDIUM VOLTAGE SYSTEMS: cR COIL (RELAY, TIMER, MOTOR STARTER, ETC.) A/2a,4b,6c HOME RUN-PANEL/CIRCUIT (IE. A/2a=PANEL A AND (CR-1 DESIGNATES CONTROL RELAY NO. 1) USE T FOR CIRCUIT 2a) SLASH MARKS INDICATE QUANTITY OF CONDUCTORS MEDIUM VOLTAGE TIMER, M 1 FOR MOTOR STARTER NO. 1, D FOR DELAY, ETC. (SIZE NOTED). LONGER SLASH INDICATES NEUTRAL WIRE (IF REQ'D). "A" PHASE (LEFT BUS IN PANEL 1 STRIPE OF VIOLET TAPE REVERSED SLASH INDICATES GROUND WIRE. "B" PHASE ( CENTER BUS IN PANEL) 2 STRIPES OF VIOLET TAPE A ° RELAY ANSI STANDARD NUMBER FOR FUNCTION "C" PHASE (RIGHT BUS IN PANEL) 3 STRIPES OF VIOLET TAPE (NOTED LETTER IDENTIFIES SPECIFIC RELAY) HH ________ HANDHOLE CONDUIT, UNDERGROUND, DIRECT BURIED. CAPACITOR 4. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, X FIRE SEAL THROUGH THE WALL CONDUITS & CONDUCTORS SWITCHES, ETC. WITH CIRCUIT IDENTIFICATION. OM METER (TYPE AS NOTED) X FIRE SEAL THROUGH THE WALL WIREWAY & CONDUCTORS A - AMMETER KW - KILOWATT METER CONDUIT TURNING DOWN KWH - KILOWATT HOUR METER o CONDUIT TURNING UP PF - POWER FACTOR METER . CONDUIT TERMINATED ABOVE CEILING V - VOLTMETER VAR - VAR METER CONDUIT EXPOSED (RIGID METAL IMC, EMT OR AS NOTED) FR - FREQUENCY — — — CONCEALED CONDUIT (UNDERGROUND, UNDER FLOOR, IN WALL OR IN CEILING) KEY INTERLOCK T TELEPHONE BATTERY FA FIRE ALARM CIRCUIT (ADT) ���-ZOA. DUPLEX RECEPTACLE, 120V, 20. TYPICAL (WP=WEATHER PROOF; GF1= GROUND CONNECTION GROUND FAULT INTERRUPTER) 2 3 4 TERMINAL BLOCK (4 TERMINALS) 0#3° DUPLEX RECEPTACLE, 120V, 15A. CIRCUIT 3a �DED DEDICATED RECEPTACLE ON DEDICATED CIRCUIT R) INDICATOR LIGHT (RED) R=RED, A=AMBER, (SPECIAL RECEPTACLES TO BE NOTED AS TO MFG. & jam= G=GREEN, B=BLUE CATALOG NUMBER) WIRE CROSSING, NOT SPLICED 1&20 SINGLE TWISTLOCK RECEPTACLE 120V, 20A FOURPLEX RECEPTACLE, 120V, 20A -J- WIRE SPLICEDZo SINGLE PHASE 208V RECEPTACLE (TYPE AS NOTED) TR TRANSFORMER RELAY k THREE PHASE RECEPTACLE (TYPE AS NOTED) PIGTAIL CONNECTION 13D THREE PHASE RECEPTACLE (TYPE AS NOTED) t� DUPLEX RECEPTACLE IN FLOOR X EQUIPMENT IDENTIFIER I TELEPHONE OUTLET Y X = NAME, Y = HP, KW, OR KVA ❑! TELEPHONE OUTLET IN FLOOR A 10 IDENTIFIES LUMINAIRE TYPE & WATTAGE (A=TYPE, 100=WATTAGE) 13�1 HORN WALL MOUNTED LUMINAIRE (TYPE AND WATTAGE AS NOTED) Ill MANUAL FIRE ALARM PULL STATION HIGH INTENSITY DISCHARGE LUMINAIRE (TYPE AND WATTAGE < s SMOKE DETECTION HEAD b 27502f) AS NOTED) OH HEAT DETECTOR -RATE OF RISE 0-0 ROADWAY/PARKING CUTOFF LUMINAIRE (TYPE AND WATTAGE 6 BUZZER AS NOTED) Q COMPUTER WALL OUTLET ®1 EXIT LUMINAIRE, CEILING MOUNTED, DIRECTION OF EGRESS $ SINGLE POLE TOGGLE SWITCH NOTED �_o I EXIT LUMINAIRE, WALL MOUNTED, DIRECTION OF EGRESS $3 THREE-WAY TOGGLE SWITCH NOTED ■ MAGNETIC DOOR RELEASE —- CONDUIT W/ SEAL FITTING (HAZARDOUS AREAS) ,cc MOTOR CONTROL CENTER RECORD DRAWING INFORMATION COMPILED 222 FROM CONTRACTOR'S RECORDS. LICENSEE o��c/s°G�� IS NOT RESPONSIBLE FOR ACCURACY OR SJONAL AS B�FORAPPROVALBY COMPLETENESS OF CONTRACTOR'S RECORDS. RECOMMENDED BY 1 ; ' �' ; EXPIRES: 06/05/'02 (RECORD DRAWING, BY `--mm-----------mom 4mmmmmmmmmmmmmmmmmNo* SCANNED UCT 4 2(00